메뉴 건너뛰기




Volumn 36, Issue 5, 2012, Pages 1015-1036

4D flow MRI

Author keywords

4D flow MRI; aorta; blood flow; carotid bifurcation; heart; hemodynamics; hepatic arteries; intracranial arteries; PC VIPR; peripheral arteries; phase contrast; pulmonary arteries; renal arteries; respiration control; self gating

Indexed keywords

AORTA ATHEROSCLEROSIS; AORTA COARCTATION; ARTERIAL PRESSURE; ARTERY BLOOD FLOW; ASCENDING AORTA; BLOOD FLOW VELOCITY; BRAIN ARTERY ANEURYSM; BRAIN BLOOD FLOW; CARDIAC GATED IMAGING; CARDIOVASCULAR MAGNETIC RESONANCE; CEREBROVASCULAR ACCIDENT; COMPUTATIONAL FLUID DYNAMICS; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONGESTIVE CARDIOMYOPATHY; CONTRAST ENHANCEMENT; CORONARY ARTERY BLOOD FLOW; DIAPHRAGM; DISEASE SEVERITY; DOPPLER FLOWMETRY; GREAT BLOOD VESSEL; HEART CYCLE; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART LEFT VENTRICLE FILLING; HEMODYNAMICS; HUMAN; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGE QUALITY; IMAGE RECONSTRUCTION; INTERNAL CAROTID ARTERY; KIDNEY ARTERY; KIDNEY ARTERY STENOSIS; LIVER CIRRHOSIS; LIVER VEIN; MAGNETIC RESONANCE ANGIOGRAPHY; MITRAL VALVE; MITRAL VALVE REGURGITATION; PERIPHERAL OCCLUSIVE ARTERY DISEASE; PORTAL HYPERTENSION; PORTAL VEIN; PRIORITY JOURNAL; PULMONARY ARTERY; PULSE WAVE; RESPIRATION CONTROL; RESPIRATORY GATED IMAGING; REVIEW; RISK FACTOR; SHEAR STRESS; SIGNAL NOISE RATIO; THORACIC AORTA; TRICUSPID VALVE; VEIN BLOOD FLOW;

EID: 84867819825     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.23632     Document Type: Review
Times cited : (671)

References (172)
  • 1
    • 33847534249 scopus 로고
    • Effects of diffusion on free precession in nuclear magnetic resonance experiments
    • Carr HY, Purcell EM,. Effects of diffusion on free precession in nuclear magnetic resonance experiments. Phys Rev 1954; 94: 30-38.
    • (1954) Phys Rev , vol.94 , pp. 30-38
    • Carr, H.Y.1    Purcell, E.M.2
  • 2
    • 0001722873 scopus 로고
    • Detection of sea water motion by nuclear precession
    • Hahn EL,. Detection of sea water motion by nuclear precession. J Geophys Res 1960; 65.
    • (1960) J Geophys Res , pp. 65
    • Hahn, E.L.1
  • 3
    • 0020340302 scopus 로고
    • A flow velocity zeugmatographic interlace for NMR imaging in humans
    • Moran PR,. A flow velocity zeugmatographic interlace for NMR imaging in humans. Magn Reson Imaging 1982; 1: 197-203.
    • (1982) Magn Reson Imaging , vol.1 , pp. 197-203
    • Moran, P.R.1
  • 4
    • 0021282475 scopus 로고
    • Measurement of flow with NMR imaging using a gradient pulse and phase difference technique
    • Bryant DJ, Payne JA, Firmin DN, Longmore DB,. Measurement of flow with NMR imaging using a gradient pulse and phase difference technique. J Comput Assist Tomogr 1984; 8: 588-593.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 588-593
    • Bryant, D.J.1    Payne, J.A.2    Firmin, D.N.3    Longmore, D.B.4
  • 5
    • 0021235637 scopus 로고
    • Direct cardiac NMR imaging of heart wall and blood flow velocity
    • Van Dijk P,. Direct cardiac NMR imaging of heart wall and blood flow velocity. J Comput Assist Tomogr 1984; 171: 429-436.
    • (1984) J Comput Assist Tomogr , vol.171 , pp. 429-436
    • Van Dijk, P.1
  • 8
    • 23844557784 scopus 로고    scopus 로고
    • How we perform cardiovascular magnetic resonance flow assessment using phase-contrast velocity mapping
    • Chai P, Mohiaddin R,. How we perform cardiovascular magnetic resonance flow assessment using phase-contrast velocity mapping. J Cardiovasc Magn Reson 2005; 7: 705-716.
    • (2005) J Cardiovasc Magn Reson , vol.7 , pp. 705-716
    • Chai, P.1    Mohiaddin, R.2
  • 10
    • 0029097148 scopus 로고
    • Magnetic resonance velocity vector mapping of blood flow in thoracic aortic aneurysms and grafts
    • Bogren HG, Mohiaddin RH, Yang GZ, Kilner PJ, Firmin DN,. Magnetic resonance velocity vector mapping of blood flow in thoracic aortic aneurysms and grafts. J Thorac Cardiovasc Surg 1995; 110: 704-714.
    • (1995) J Thorac Cardiovasc Surg , vol.110 , pp. 704-714
    • Bogren, H.G.1    Mohiaddin, R.H.2    Yang, G.Z.3    Kilner, P.J.4    Firmin, D.N.5
  • 11
    • 0029964796 scopus 로고    scopus 로고
    • Temporally resolved 3D phase-contrast imaging
    • Wigstrom L, Sjoqvist L, Wranne B,. Temporally resolved 3D phase-contrast imaging. Magn Reson Med 1996; 36: 800-803.
    • (1996) Magn Reson Med , vol.36 , pp. 800-803
    • Wigstrom, L.1    Sjoqvist, L.2    Wranne, B.3
  • 12
    • 12244274310 scopus 로고    scopus 로고
    • Time-resolved three-dimensional phase-contrast MRI
    • Markl M, Chan FP, Alley MT, et al. Time-resolved three-dimensional phase-contrast MRI. J Magn Reson Imaging 2003; 17: 499-506.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 499-506
    • Markl, M.1    Chan, F.P.2    Alley, M.T.3
  • 13
    • 0031397482 scopus 로고    scopus 로고
    • Blood flow patterns in the thoracic aorta studied with three-directional MR velocity mapping: The effects of age and coronary artery disease
    • Bogren HG, Mohiaddin RH, Kilner PJ, Jimenez-Borreguero LJ, Yang GZ, Firmin DN,. Blood flow patterns in the thoracic aorta studied with three-directional MR velocity mapping: the effects of age and coronary artery disease. J Magn Reson Imaging 1997; 7: 784-793.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 784-793
    • Bogren, H.G.1    Mohiaddin, R.H.2    Kilner, P.J.3    Jimenez-Borreguero, L.J.4    Yang, G.Z.5    Firmin, D.N.6
  • 14
    • 0031830533 scopus 로고    scopus 로고
    • Visualizing blood flow patterns using streamlines, arrows, and particle paths
    • Buonocore MH,. Visualizing blood flow patterns using streamlines, arrows, and particle paths. Magn Reson Med 1998; 40: 210-226.
    • (1998) Magn Reson Med , vol.40 , pp. 210-226
    • Buonocore, M.H.1
  • 15
    • 0032915991 scopus 로고    scopus 로고
    • Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI
    • Wigstrom L, Ebbers T, Fyrenius A, et al. Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI. Magn Reson Med 1999; 41: 793-799.
    • (1999) Magn Reson Med , vol.41 , pp. 793-799
    • Wigstrom, L.1    Ebbers, T.2    Fyrenius, A.3
  • 17
    • 0035028867 scopus 로고    scopus 로고
    • Visualization of flow patterns distal to aortic valve prostheses in humans using a fast approach for cine 3D velocity mapping
    • Kozerke S, Hasenkam JM, Pedersen EM, Boesiger P,. Visualization of flow patterns distal to aortic valve prostheses in humans using a fast approach for cine 3D velocity mapping. J Magn Reson Imaging 2001; 13: 690-698.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 690-698
    • Kozerke, S.1    Hasenkam, J.M.2    Pedersen, E.M.3    Boesiger, P.4
  • 18
    • 33846597931 scopus 로고    scopus 로고
    • Time-resolved, 3-dimensional magnetic resonance flow analysis at 3 T: Visualization of normal and pathological aortic vascular hemodynamics
    • Frydrychowicz A, Harloff A, Jung B, et al. Time-resolved, 3-dimensional magnetic resonance flow analysis at 3 T: visualization of normal and pathological aortic vascular hemodynamics. J Comput Assist Tomogr 2007; 31: 9-15.
    • (2007) J Comput Assist Tomogr , vol.31 , pp. 9-15
    • Frydrychowicz, A.1    Harloff, A.2    Jung, B.3
  • 19
    • 37349004799 scopus 로고    scopus 로고
    • Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping
    • Hope TA, Markl M, Wigstrom L, Alley MT, Miller DC, Herfkens RJ,. Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping. J Magn Reson Imaging 2007; 26: 1471-1479.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 1471-1479
    • Hope, T.A.1    Markl, M.2    Wigstrom, L.3    Alley, M.T.4    Miller, D.C.5    Herfkens, R.J.6
  • 20
    • 55749085612 scopus 로고    scopus 로고
    • Quantitative 2D and 3D phase contrast MRI: Optimized analysis of blood flow and vessel wall parameters
    • Stalder AF, Russe MF, Frydrychowicz A, Bock J, Hennig J, Markl M,. Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters. Magn Reson Med 2008; 60: 1218-1231.
    • (2008) Magn Reson Med , vol.60 , pp. 1218-1231
    • Stalder, A.F.1    Russe, M.F.2    Frydrychowicz, A.3    Bock, J.4    Hennig, J.5    Markl, M.6
  • 21
    • 70349656499 scopus 로고    scopus 로고
    • Flow assessment through four heart valves simultaneously using 3-dimensional 3-directional velocity-encoded magnetic resonance imaging with retrospective valve tracking in healthy volunteers and patients with valvular regurgitation
    • Roes SD, Hammer S, van der Geest RJ, et al. Flow assessment through four heart valves simultaneously using 3-dimensional 3-directional velocity-encoded magnetic resonance imaging with retrospective valve tracking in healthy volunteers and patients with valvular regurgitation. Invest Radiol 2009; 44: 669-675.
    • (2009) Invest Radiol , vol.44 , pp. 669-675
    • Roes, S.D.1    Hammer, S.2    Van Der Geest, R.J.3
  • 22
    • 78449310701 scopus 로고    scopus 로고
    • 4D phase-contrast flow cardiovascular magnetic resonance: Comprehensive quantification and visualization of flow dynamics in atrial septal defect and partial anomalous pulmonary venous return
    • Valverde I, Simpson J, Schaeffter T, Beerbaum P,. 4D phase-contrast flow cardiovascular magnetic resonance: comprehensive quantification and visualization of flow dynamics in atrial septal defect and partial anomalous pulmonary venous return. Pediatr Cardiol 2010; 31: 1244-1248.
    • (2010) Pediatr Cardiol , vol.31 , pp. 1244-1248
    • Valverde, I.1    Simpson, J.2    Schaeffter, T.3    Beerbaum, P.4
  • 23
    • 79953247319 scopus 로고    scopus 로고
    • Reproducibility of flow and wall shear stress analysis using flow-sensitive four-dimensional MRI
    • Markl M, Wallis W, Harloff A,. Reproducibility of flow and wall shear stress analysis using flow-sensitive four-dimensional MRI. J Magn Reson Imaging 2011; 33: 988-994.
    • (2011) J Magn Reson Imaging , vol.33 , pp. 988-994
    • Markl, M.1    Wallis, W.2    Harloff, A.3
  • 24
    • 0032414336 scopus 로고    scopus 로고
    • Automatic accurate non-invasive quantitation of blood flow, cross-sectional vessel area, and wall shear stress by modelling of magnetic resonance velocity data
    • Oyre S, Paaske WP, Ringgaard S, et al. Automatic accurate non-invasive quantitation of blood flow, cross-sectional vessel area, and wall shear stress by modelling of magnetic resonance velocity data. Eur J Vasc Endovasc Surg 1998; 16: 517-524.
    • (1998) Eur J Vasc Endovasc Surg , vol.16 , pp. 517-524
    • Oyre, S.1    Paaske, W.P.2    Ringgaard, S.3
  • 25
    • 0029399233 scopus 로고
    • Determination of wall shear stress in the aorta with the use of MR phase velocity mapping
    • Oshinski JN, Ku DN, Mukundan S Jr, Loth F, Pettigrew RI,. Determination of wall shear stress in the aorta with the use of MR phase velocity mapping. J Magn Reson Imaging 1995; 5: 640-647.
    • (1995) J Magn Reson Imaging , vol.5 , pp. 640-647
    • Oshinski, J.N.1    Ku, D.N.2    Mukundan, Jr.S.3    Loth, F.4    Pettigrew, R.I.5
  • 26
    • 67650035152 scopus 로고    scopus 로고
    • Three-dimensional analysis of segmental wall shear stress in the aorta by flow-sensitive four-dimensional-MRI
    • Frydrychowicz A, Stalder AF, Russe MF, et al. Three-dimensional analysis of segmental wall shear stress in the aorta by flow-sensitive four-dimensional-MRI. J Magn Reson Imaging 2009; 30: 77-84.
    • (2009) J Magn Reson Imaging , vol.30 , pp. 77-84
    • Frydrychowicz, A.1    Stalder, A.F.2    Russe, M.F.3
  • 29
    • 0033852691 scopus 로고    scopus 로고
    • Three-dimensional, time-resolved (4D) relative pressure mapping using magnetic resonance imaging
    • Tyszka JM, Laidlaw DH, Asa JW, Silverman JM,. Three-dimensional, time-resolved (4D) relative pressure mapping using magnetic resonance imaging. J Magn Reson Imaging 2000; 12: 321-329.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 321-329
    • Tyszka, J.M.1    Laidlaw, D.H.2    Asa, J.W.3    Silverman, J.M.4
  • 30
    • 0036260694 scopus 로고    scopus 로고
    • Noninvasive measurement of time-varying three-dimensional relative pressure fields within the human heart
    • Ebbers T, Wigstrom L, Bolger AF, Wranne B, Karlsson M,. Noninvasive measurement of time-varying three-dimensional relative pressure fields within the human heart. J Biomech Eng 2002; 124: 288-293.
    • (2002) J Biomech Eng , vol.124 , pp. 288-293
    • Ebbers, T.1    Wigstrom, L.2    Bolger, A.F.3    Wranne, B.4    Karlsson, M.5
  • 31
    • 80052971580 scopus 로고    scopus 로고
    • In vivo noninvasive 4D pressure difference mapping in the human aorta: Phantom comparison and application in healthy volunteers and patients
    • Bock J, Frydrychowicz A, Lorenz R, et al. In vivo noninvasive 4D pressure difference mapping in the human aorta: phantom comparison and application in healthy volunteers and patients. Magn Reson Med 2011; 66: 1079-1088.
    • (2011) Magn Reson Med , vol.66 , pp. 1079-1088
    • Bock, J.1    Frydrychowicz, A.2    Lorenz, R.3
  • 32
    • 51449112368 scopus 로고    scopus 로고
    • Assessment of fluctuating velocities in disturbed cardiovascular blood flow: In vivo feasibility of generalized phase-contrast MRI
    • Dyverfeldt P, Kvitting JP, Sigfridsson A, Engvall J, Bolger AF, Ebbers T,. Assessment of fluctuating velocities in disturbed cardiovascular blood flow: in vivo feasibility of generalized phase-contrast MRI. J Magn Reson Imaging 2008; 28: 655-663.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 655-663
    • Dyverfeldt, P.1    Kvitting, J.P.2    Sigfridsson, A.3    Engvall, J.4    Bolger, A.F.5    Ebbers, T.6
  • 35
    • 0026912776 scopus 로고
    • Minimizing TE in moment-nulled or flow-encoded two- and three-dimensional gradient-echo imaging
    • Bernstein MA, Shimakawa A, Pelc NJ,. Minimizing TE in moment-nulled or flow-encoded two- and three-dimensional gradient-echo imaging. J Magn Reson Imaging 1992; 2: 583-588.
    • (1992) J Magn Reson Imaging , vol.2 , pp. 583-588
    • Bernstein, M.A.1    Shimakawa, A.2    Pelc, N.J.3
  • 36
    • 0025961482 scopus 로고
    • Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence
    • Atkinson DJ, Edelman RR,. Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence. Radiology 1991; 178: 357-360.
    • (1991) Radiology , vol.178 , pp. 357-360
    • Atkinson, D.J.1    Edelman, R.R.2
  • 37
    • 0029339826 scopus 로고
    • A segmented k-space velocity mapping protocol for quantification of renal artery blood flow during breath-holding
    • Thomsen C, Cortsen M, Sondergaard L, Henriksen O, Stahlberg F,. A segmented k-space velocity mapping protocol for quantification of renal artery blood flow during breath-holding. J Magn Reson Imaging 1995; 5: 393-401.
    • (1995) J Magn Reson Imaging , vol.5 , pp. 393-401
    • Thomsen, C.1    Cortsen, M.2    Sondergaard, L.3    Henriksen, O.4    Stahlberg, F.5
  • 38
    • 34047115315 scopus 로고    scopus 로고
    • Time-resolved 3D MR velocity mapping at 3T: Improved navigator-gated assessment of vascular anatomy and blood flow
    • Markl M, Harloff A, Bley TA, et al. Time-resolved 3D MR velocity mapping at 3T: improved navigator-gated assessment of vascular anatomy and blood flow. J Magn Reson Imaging 2007; 25: 824-831.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 824-831
    • Markl, M.1    Harloff, A.2    Bley, T.A.3
  • 40
    • 75749111626 scopus 로고    scopus 로고
    • Improved SNR in phase contrast velocimetry with five-point balanced flow encoding
    • Johnson KM, Markl M,. Improved SNR in phase contrast velocimetry with five-point balanced flow encoding. Magn Reson Med 2010; 63: 349-355.
    • (2010) Magn Reson Med , vol.63 , pp. 349-355
    • Johnson, K.M.1    Markl, M.2
  • 41
    • 0242322611 scopus 로고    scopus 로고
    • Accuracy and reproducibility in phase contrast imaging using SENSE
    • Thunberg P, Karlsson M, Wigstrom L,. Accuracy and reproducibility in phase contrast imaging using SENSE. Magn Reson Med 2003; 50: 1061-1068.
    • (2003) Magn Reson Med , vol.50 , pp. 1061-1068
    • Thunberg, P.1    Karlsson, M.2    Wigstrom, L.3
  • 44
    • 0027093023 scopus 로고
    • Projection reconstruction techniques for reduction of motion effects in MRI
    • Glover GH, Pauly JM,. Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson Med 1992; 28: 275-289.
    • (1992) Magn Reson Med , vol.28 , pp. 275-289
    • Glover, G.H.1    Pauly, J.M.2
  • 45
    • 0034026094 scopus 로고    scopus 로고
    • Phase-contrast with interleaved undersampled projections
    • Barger AV, Peters DC, Block WF, et al. Phase-contrast with interleaved undersampled projections. Magn Reson Med 2000; 43: 503-509.
    • (2000) Magn Reson Med , vol.43 , pp. 503-509
    • Barger, A.V.1    Peters, D.C.2    Block, W.F.3
  • 46
    • 30344456972 scopus 로고    scopus 로고
    • PC VIPR: A high-speed 3D phase-contrast method for flow quantification and high-resolution angiography
    • Gu T, Korosec FR, Block WF, et al. PC VIPR: a high-speed 3D phase-contrast method for flow quantification and high-resolution angiography. AJNR Am J Neuroradiol 2005; 26: 743-749.
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 743-749
    • Gu, T.1    Korosec, F.R.2    Block, W.F.3
  • 47
    • 31644444335 scopus 로고    scopus 로고
    • Generation and visualization of four-dimensional MR angiography data using an undersampled 3-D projection trajectory
    • Liu J, Redmond MJ, Brodsky EK, et al. Generation and visualization of four-dimensional MR angiography data using an undersampled 3-D projection trajectory. IEEE Trans Med Imaging 2006; 25: 148-157.
    • (2006) IEEE Trans Med Imaging , vol.25 , pp. 148-157
    • Liu, J.1    Redmond, M.J.2    Brodsky, E.K.3
  • 49
    • 0027450251 scopus 로고
    • Consistent projection reconstruction (CPR) techniques for MRI
    • Glover GH, Noll DC,. Consistent projection reconstruction (CPR) techniques for MRI. Magn Reson Med 1993; 29: 345-351.
    • (1993) Magn Reson Med , vol.29 , pp. 345-351
    • Glover, G.H.1    Noll, D.C.2
  • 51
    • 22744432670 scopus 로고    scopus 로고
    • Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction
    • Stehning C, Bornert P, Nehrke K, Eggers H, Stuber M,. Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction. Magn Reson Med 2005; 54: 476-480.
    • (2005) Magn Reson Med , vol.54 , pp. 476-480
    • Stehning, C.1    Bornert, P.2    Nehrke, K.3    Eggers, H.4    Stuber, M.5
  • 52
    • 78650629874 scopus 로고    scopus 로고
    • Renal arteries: Isotropic, high-spatial-resolution, unenhanced MR angiography with three-dimensional radial phase contrast
    • Francois CJ, Lum DP, Johnson KM, et al. Renal arteries: isotropic, high-spatial-resolution, unenhanced MR angiography with three-dimensional radial phase contrast. Radiology 2011; 258: 254-260.
    • (2011) Radiology , vol.258 , pp. 254-260
    • Francois, C.J.1    Lum, D.P.2    Johnson, K.M.3
  • 53
    • 35349014104 scopus 로고    scopus 로고
    • Noninvasive measurement of intra-aneurysmal pressure and flow pattern using phase contrast with vastly undersampled isotropic projection imaging
    • Moftakhar R, Aagaard-Kienitz B, Johnson K, et al. Noninvasive measurement of intra-aneurysmal pressure and flow pattern using phase contrast with vastly undersampled isotropic projection imaging. AJNR Am J Neuroradiol 2007; 28: 1710-1714.
    • (2007) AJNR Am J Neuroradiol , vol.28 , pp. 1710-1714
    • Moftakhar, R.1    Aagaard-Kienitz, B.2    Johnson, K.3
  • 54
    • 33846408001 scopus 로고    scopus 로고
    • Physiologic and anatomic assessment of a canine carotid artery stenosis model utilizing phase contrast with vastly undersampled isotropic projection imaging
    • Turk AS, Johnson KM, Lum D, et al. Physiologic and anatomic assessment of a canine carotid artery stenosis model utilizing phase contrast with vastly undersampled isotropic projection imaging. AJNR Am J Neuroradiol 2007; 28: 111-115.
    • (2007) AJNR Am J Neuroradiol , vol.28 , pp. 111-115
    • Turk, A.S.1    Johnson, K.M.2    Lum, D.3
  • 55
    • 36248995983 scopus 로고    scopus 로고
    • Transstenotic pressure gradients: Measurement in swine-retrospectively ECG-gated 3D phase-contrast MR angiography versus endovascular pressure-sensing guidewires
    • Lum DP, Johnson KM, Paul RK, et al. Transstenotic pressure gradients: measurement in swine-retrospectively ECG-gated 3D phase-contrast MR angiography versus endovascular pressure-sensing guidewires. Radiology 2007; 245: 751-760.
    • (2007) Radiology , vol.245 , pp. 751-760
    • Lum, D.P.1    Johnson, K.M.2    Paul, R.K.3
  • 56
    • 80053061798 scopus 로고    scopus 로고
    • Noninvasive assessment of transstenotic pressure gradients in porcine renal artery stenoses using vastly undersampled phase contrast MRA
    • Bley TA, Johnson KM, Francois CJ, et al. Noninvasive assessment of transstenotic pressure gradients in porcine renal artery stenoses using vastly undersampled phase contrast MRA. Radiology 2011; 261: 266-273.
    • (2011) Radiology , vol.261 , pp. 266-273
    • Bley, T.A.1    Johnson, K.M.2    Francois, C.J.3
  • 57
    • 77953758086 scopus 로고    scopus 로고
    • Images in Cardiovascular Medicine. Scimitar syndrome: Added value by isotropic flow-sensitive four-dimensional magnetic resonance imaging with PC-VIPR (phase-contrast vastly undersampled isotropic projection reconstruction)
    • Frydrychowicz A, Landgraf B, Wieben O, Francois CJ,. Images in Cardiovascular Medicine. Scimitar syndrome: added value by isotropic flow-sensitive four-dimensional magnetic resonance imaging with PC-VIPR (phase-contrast vastly undersampled isotropic projection reconstruction). Circulation 2010; 121: e434-436.
    • (2010) Circulation , vol.121
    • Frydrychowicz, A.1    Landgraf, B.2    Wieben, O.3    Francois, C.J.4
  • 58
    • 78651496022 scopus 로고    scopus 로고
    • Velocity measurements in the middle cerebral arteries of healthy volunteers using 3D radial phase-contrast HYPRFlow: Comparison with transcranial Doppler sonography and 2D phase-contrast MR imaging
    • Chang W, Landgraf B, Johnson KM, et al. Velocity measurements in the middle cerebral arteries of healthy volunteers using 3D radial phase-contrast HYPRFlow: comparison with transcranial Doppler sonography and 2D phase-contrast MR imaging. AJNR Am J Neuroradiol 2011; 32: 54-59.
    • (2011) AJNR Am J Neuroradiol , vol.32 , pp. 54-59
    • Chang, W.1    Landgraf, B.2    Johnson, K.M.3
  • 59
    • 80051929334 scopus 로고    scopus 로고
    • Four-dimensional velocity mapping of the hepatic and splanchnic vasculature with radial sampling at 3 Tesla: A feasibility study in portal hypertension
    • Frydrychowicz A, Landgraf BR, Niespodzany E, et al. Four-dimensional velocity mapping of the hepatic and splanchnic vasculature with radial sampling at 3 Tesla: a feasibility study in portal hypertension. J Magn Reson Imaging 2011; 34: 577-584.
    • (2011) J Magn Reson Imaging , vol.34 , pp. 577-584
    • Frydrychowicz, A.1    Landgraf, B.R.2    Niespodzany, E.3
  • 60
    • 0024453449 scopus 로고
    • Adaptive technique for high-definition MR imaging of moving structures
    • Ehman RL, Felmlee JP,. Adaptive technique for high-definition MR imaging of moving structures. Radiology 1989; 173: 255-263.
    • (1989) Radiology , vol.173 , pp. 255-263
    • Ehman, R.L.1    Felmlee, J.P.2
  • 61
    • 0030966347 scopus 로고    scopus 로고
    • Comparison of respiratory suppression methods and navigator locations for MR coronary angiography
    • McConnell MV, Khasgiwala VC, Savord BJ, et al. Comparison of respiratory suppression methods and navigator locations for MR coronary angiography. AJR Am J Roentgenol 1997; 168: 1369-1375.
    • (1997) AJR Am J Roentgenol , vol.168 , pp. 1369-1375
    • McConnell, M.V.1    Khasgiwala, V.C.2    Savord, B.J.3
  • 62
    • 0030026702 scopus 로고    scopus 로고
    • Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography
    • Wang Y, Rossman PJ, Grimm RC, Riederer SJ, Ehman RL,. Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. Radiology 1996; 198: 55-60.
    • (1996) Radiology , vol.198 , pp. 55-60
    • Wang, Y.1    Rossman, P.J.2    Grimm, R.C.3    Riederer, S.J.4    Ehman, R.L.5
  • 63
    • 11144300903 scopus 로고    scopus 로고
    • Retrospective respiratory motion correction for navigated cine velocity mapping
    • Baltes C, Kozerke S, Atkinson D, Boesiger P,. Retrospective respiratory motion correction for navigated cine velocity mapping. J Cardiovasc Magn Reson 2004; 6: 785-792.
    • (2004) J Cardiovasc Magn Reson , vol.6 , pp. 785-792
    • Baltes, C.1    Kozerke, S.2    Atkinson, D.3    Boesiger, P.4
  • 64
    • 0022260368 scopus 로고
    • Respiratory ordered phase encoding (ROPE): A method for reducing respiratory motion artefacts in MR imaging
    • Bailes DR, Gilderdale DJ, Bydder GM, Collins AG, Firmin DN,. Respiratory ordered phase encoding (ROPE): a method for reducing respiratory motion artefacts in MR imaging. J Comput Assist Tomogr 1985; 9: 835-838.
    • (1985) J Comput Assist Tomogr , vol.9 , pp. 835-838
    • Bailes, D.R.1    Gilderdale, D.J.2    Bydder, G.M.3    Collins, A.G.4    Firmin, D.N.5
  • 65
    • 0026011828 scopus 로고
    • Adaptive motion compensation in MRI: Accuracy of motion measurement
    • Felmlee JP, Ehman RL, Riederer SJ, Korin HW,. Adaptive motion compensation in MRI: accuracy of motion measurement. Magn Reson Med 1991; 18: 207-213.
    • (1991) Magn Reson Med , vol.18 , pp. 207-213
    • Felmlee, J.P.1    Ehman, R.L.2    Riederer, S.J.3    Korin, H.W.4
  • 66
    • 0028929929 scopus 로고
    • Respiratory motion of the heart: Kinematics and the implications for the spatial resolution in coronary imaging
    • Wang Y, Riederer SJ, Ehman RL,. Respiratory motion of the heart: kinematics and the implications for the spatial resolution in coronary imaging. Magn Reson Med 1995; 33: 713-719.
    • (1995) Magn Reson Med , vol.33 , pp. 713-719
    • Wang, Y.1    Riederer, S.J.2    Ehman, R.L.3
  • 67
    • 0034874006 scopus 로고    scopus 로고
    • Free-breathing cardiac MR imaging: Study of implications of respiratory motion-initial results
    • Nehrke K, Bornert P, Manke D, Bock JC,. Free-breathing cardiac MR imaging: study of implications of respiratory motion-initial results. Radiology 2001; 220: 810-815.
    • (2001) Radiology , vol.220 , pp. 810-815
    • Nehrke, K.1    Bornert, P.2    Manke, D.3    Bock, J.C.4
  • 68
    • 51449123206 scopus 로고    scopus 로고
    • Prospective self-gating for simultaneous compensation of cardiac and respiratory motion
    • Buehrer M, Curcic J, Boesiger P, Kozerke S,. Prospective self-gating for simultaneous compensation of cardiac and respiratory motion. Magn Reson Med 2008; 60: 683-690.
    • (2008) Magn Reson Med , vol.60 , pp. 683-690
    • Buehrer, M.1    Curcic, J.2    Boesiger, P.3    Kozerke, S.4
  • 69
    • 33847749977 scopus 로고    scopus 로고
    • Whole-heart cine MRI using real-time respiratory self-gating
    • Uribe S, Muthurangu V, Boubertakh R, et al. Whole-heart cine MRI using real-time respiratory self-gating. Magn Reson Med 2007; 57: 606-613.
    • (2007) Magn Reson Med , vol.57 , pp. 606-613
    • Uribe, S.1    Muthurangu, V.2    Boubertakh, R.3
  • 70
    • 70349625820 scopus 로고    scopus 로고
    • Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating
    • Uribe S, Beerbaum P, Sorensen TS, Rasmusson A, Razavi R, Schaeffter T,. Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating. Magn Reson Med 2009; 62: 984-992.
    • (2009) Magn Reson Med , vol.62 , pp. 984-992
    • Uribe, S.1    Beerbaum, P.2    Sorensen, T.S.3    Rasmusson, A.4    Razavi, R.5    Schaeffter, T.6
  • 73
    • 46849091615 scopus 로고    scopus 로고
    • Generalized reconstruction by inversion of coupled systems (GRICS) applied to free-breathing MRI
    • Odille F, Vuissoz PA, Marie PY, Felblinger J,. Generalized reconstruction by inversion of coupled systems (GRICS) applied to free-breathing MRI. Magn Reson Med 2008; 60: 146-157.
    • (2008) Magn Reson Med , vol.60 , pp. 146-157
    • Odille, F.1    Vuissoz, P.A.2    Marie, P.Y.3    Felblinger, J.4
  • 75
    • 0031951298 scopus 로고    scopus 로고
    • Concomitant gradient terms in phase contrast MR: Analysis and correction
    • Bernstein MA, Zhou XJ, Polzin JA, et al. Concomitant gradient terms in phase contrast MR: analysis and correction. Magn Reson Med 1998; 39: 300-308.
    • (1998) Magn Reson Med , vol.39 , pp. 300-308
    • Bernstein, M.A.1    Zhou, X.J.2    Polzin, J.A.3
  • 76
    • 0141617513 scopus 로고    scopus 로고
    • Generalized reconstruction of phase contrast MRI: Analysis and correction of the effect of gradient field distortions
    • Markl M, Bammer R, Alley MT, et al. Generalized reconstruction of phase contrast MRI: analysis and correction of the effect of gradient field distortions. Magn Reson Med 2003; 50: 791-801.
    • (2003) Magn Reson Med , vol.50 , pp. 791-801
    • Markl, M.1    Bammer, R.2    Alley, M.T.3
  • 77
    • 33749046272 scopus 로고    scopus 로고
    • Is there a causal relation between the administration of gadolinium-based contrast media and the development of nephrogenic systemic fibrosis (NSF)?
    • Thomsen HS, Morcos SK, Dawson P,. Is there a causal relation between the administration of gadolinium-based contrast media and the development of nephrogenic systemic fibrosis (NSF)? Clin Radiol 2006; 61: 905-906.
    • (2006) Clin Radiol , vol.61 , pp. 905-906
    • Thomsen, H.S.1    Morcos, S.K.2    Dawson, P.3
  • 78
    • 0026248142 scopus 로고
    • Comparison of phase-difference and complex-difference processing in phase-contrast MR angiography
    • Bernstein MA, Ikezaki Y,. Comparison of phase-difference and complex-difference processing in phase-contrast MR angiography. J Magn Reson Imaging 1991; 1: 725-729.
    • (1991) J Magn Reson Imaging , vol.1 , pp. 725-729
    • Bernstein, M.A.1    Ikezaki, Y.2
  • 79
    • 0026834645 scopus 로고
    • Visualizing three-dimensional flow with simulated streamlines and three-dimensional phase-contrast MR imaging
    • Napel S, Lee DH, Frayne R, Rutt BK,. Visualizing three-dimensional flow with simulated streamlines and three-dimensional phase-contrast MR imaging. J Magn Reson Imaging 1992; 2: 143-153.
    • (1992) J Magn Reson Imaging , vol.2 , pp. 143-153
    • Napel, S.1    Lee, D.H.2    Frayne, R.3    Rutt, B.K.4
  • 80
    • 3343019140 scopus 로고    scopus 로고
    • Time-resolved 3-dimensional velocity mapping in the thoracic aorta: Visualization of 3-directional blood flow patterns in healthy volunteers and patients
    • Markl M, Draney MT, Hope MD, et al. Time-resolved 3-dimensional velocity mapping in the thoracic aorta: visualization of 3-directional blood flow patterns in healthy volunteers and patients. J Comput Assist Tomogr 2004; 28: 459-468.
    • (2004) J Comput Assist Tomogr , vol.28 , pp. 459-468
    • Markl, M.1    Draney, M.T.2    Hope, M.D.3
  • 81
    • 0027484408 scopus 로고
    • Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping
    • Kilner PJ, Yang GZ, Mohiaddin RH, Firmin DN, Longmore DB,. Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping. Circulation 1993; 88 (5 Pt 1): 2235-2247.
    • (1993) Circulation , vol.88 , Issue.5 , pp. 2235-2247
    • Kilner, P.J.1    Yang, G.Z.2    Mohiaddin, R.H.3    Firmin, D.N.4    Longmore, D.B.5
  • 82
    • 47649131679 scopus 로고    scopus 로고
    • In vivo 3-dimensional flow connectivity mapping after extracardiac total cavopulmonary connection
    • Frydrychowicz A, Arnold R, Harloff A, et al. In vivo 3-dimensional flow connectivity mapping after extracardiac total cavopulmonary connection. Circulation 2008; 118: e16-17.
    • (2008) Circulation , vol.118
    • Frydrychowicz, A.1    Arnold, R.2    Harloff, A.3
  • 83
    • 77956298959 scopus 로고    scopus 로고
    • Flow-sensitive four-dimensional cine magnetic resonance imaging for offline blood flow quantification in multiple vessels: A validation study
    • Nordmeyer S, Riesenkampff E, Crelier G, et al. Flow-sensitive four-dimensional cine magnetic resonance imaging for offline blood flow quantification in multiple vessels: a validation study. J Magn Reson Imaging 2010; 32: 677-683.
    • (2010) J Magn Reson Imaging , vol.32 , pp. 677-683
    • Nordmeyer, S.1    Riesenkampff, E.2    Crelier, G.3
  • 84
    • 78650284910 scopus 로고    scopus 로고
    • In vivo wall shear stress distribution in the carotid artery: Effect of bifurcation geometry, internal carotid artery stenosis, and recanalization therapy
    • Markl M, Wegent F, Zech T, et al. In vivo wall shear stress distribution in the carotid artery: effect of bifurcation geometry, internal carotid artery stenosis, and recanalization therapy. Circ Cardiovasc Imaging 2010; 3: 647-655.
    • (2010) Circ Cardiovasc Imaging , vol.3 , pp. 647-655
    • Markl, M.1    Wegent, F.2    Zech, T.3
  • 85
    • 33746929874 scopus 로고    scopus 로고
    • Mean-average wall shear stress measurements in the common carotid artery
    • Oshinski JN, Curtin JL, Loth F,. Mean-average wall shear stress measurements in the common carotid artery. J Cardiovasc Magn Reson 2006; 8: 717-722.
    • (2006) J Cardiovasc Magn Reson , vol.8 , pp. 717-722
    • Oshinski, J.N.1    Curtin, J.L.2    Loth, F.3
  • 86
    • 77952690199 scopus 로고    scopus 로고
    • In vivo assessment of wall shear stress in the atherosclerotic aorta using flow-sensitive 4D MRI
    • Harloff A, Nussbaumer A, Bauer S, et al. In vivo assessment of wall shear stress in the atherosclerotic aorta using flow-sensitive 4D MRI. Magn Reson Med 2010; 63: 1529-1536.
    • (2010) Magn Reson Med , vol.63 , pp. 1529-1536
    • Harloff, A.1    Nussbaumer, A.2    Bauer, S.3
  • 87
    • 77953872385 scopus 로고    scopus 로고
    • Accelerated time-resolved three-dimensional MR velocity mapping of blood flow patterns in the aorta using SENSE and k-t BLAST
    • Stadlbauer A, van der Riet W, Crelier G, Salomonowitz E,. Accelerated time-resolved three-dimensional MR velocity mapping of blood flow patterns in the aorta using SENSE and k-t BLAST. Eur J Radiol 2010; 75: e15-21.
    • (2010) Eur J Radiol , vol.75
    • Stadlbauer, A.1    Van Der Riet, W.2    Crelier, G.3    Salomonowitz, E.4
  • 89
    • 79954908979 scopus 로고    scopus 로고
    • Aortic hemodynamics in patients with and without repair of aortic coarctation: In vivo analysis by 4D flow-sensitive magnetic resonance imaging
    • Frydrychowicz A, Markl M, Hirtler D, et al. Aortic hemodynamics in patients with and without repair of aortic coarctation: in vivo analysis by 4D flow-sensitive magnetic resonance imaging. Invest Radiol 2011; 46: 317-325.
    • (2011) Invest Radiol , vol.46 , pp. 317-325
    • Frydrychowicz, A.1    Markl, M.2    Hirtler, D.3
  • 90
    • 78650275750 scopus 로고    scopus 로고
    • Four-dimensional flow magnetic resonance imaging with wall shear stress analysis before and after repair of aortopulmonary fistula
    • Hope MD, Hope TA, Urbania TH, Higgins CB,. Four-dimensional flow magnetic resonance imaging with wall shear stress analysis before and after repair of aortopulmonary fistula. Circ Cardiovasc Imaging 2010; 3: 766-768.
    • (2010) Circ Cardiovasc Imaging , vol.3 , pp. 766-768
    • Hope, M.D.1    Hope, T.A.2    Urbania, T.H.3    Higgins, C.B.4
  • 91
    • 77649220200 scopus 로고    scopus 로고
    • Clinical evaluation of aortic coarctation with 4D flow MR imaging
    • Hope MD, Meadows AK, Hope TA, et al. Clinical evaluation of aortic coarctation with 4D flow MR imaging. J Magn Reson Imaging 2010; 31: 711-718.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 711-718
    • Hope, M.D.1    Meadows, A.K.2    Hope, T.A.3
  • 92
    • 79958822075 scopus 로고    scopus 로고
    • Arch hypoplasia and aneurysm after aortic coarctation repair: Abnormal flow may be the link
    • Crook SES, Hope TA,. Arch hypoplasia and aneurysm after aortic coarctation repair: Abnormal flow may be the link. JACC Cardiovascular Imaging 2011; 4: 685-686.
    • (2011) JACC Cardiovascular Imaging , vol.4 , pp. 685-686
    • Crook, S.E.S.1    Hope, T.A.2
  • 93
    • 47049128751 scopus 로고    scopus 로고
    • Multidirectional flow analysis by cardiovascular magnetic resonance in aneurysm development following repair of aortic coarctation
    • Frydrychowicz A, Arnold R, Hirtler D, et al. Multidirectional flow analysis by cardiovascular magnetic resonance in aneurysm development following repair of aortic coarctation. J Cardiovasc Magn Reson 2008; 10: 30.
    • (2008) J Cardiovasc Magn Reson , vol.10 , pp. 30
    • Frydrychowicz, A.1    Arnold, R.2    Hirtler, D.3
  • 94
    • 37349009965 scopus 로고    scopus 로고
    • Plaques in the descending aorta: A new risk factor for stroke? Visualization of potential embolization pathways by 4D MRI
    • Harloff A, Strecker C, Frydrychowicz AP, et al. Plaques in the descending aorta: a new risk factor for stroke? Visualization of potential embolization pathways by 4D MRI. J Magn Reson Imaging 2007; 26: 1651-1655.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 1651-1655
    • Harloff, A.1    Strecker, C.2    Frydrychowicz, A.P.3
  • 95
    • 77950372132 scopus 로고    scopus 로고
    • Bicuspid aortic valve: Four-dimensional MR evaluation of ascending aortic systolic flow patterns
    • Hope MD, Hope TA, Meadows AK, et al. Bicuspid aortic valve: four-dimensional MR evaluation of ascending aortic systolic flow patterns. Radiology 2010; 255: 53-61.
    • (2010) Radiology , vol.255 , pp. 53-61
    • Hope, M.D.1    Hope, T.A.2    Meadows, A.K.3
  • 96
    • 44449140570 scopus 로고    scopus 로고
    • Images in cardiovascular medicine. Evaluation of bicuspid aortic valve and aortic coarctation with 4D flow magnetic resonance imaging
    • Hope MD, Meadows AK, Hope TA, et al. Images in cardiovascular medicine. Evaluation of bicuspid aortic valve and aortic coarctation with 4D flow magnetic resonance imaging. Circulation 2008; 117: 2818-2819.
    • (2008) Circulation , vol.117 , pp. 2818-2819
    • Hope, M.D.1    Meadows, A.K.2    Hope, T.A.3
  • 97
    • 77952009403 scopus 로고    scopus 로고
    • Quantification of hemodynamic wall shear stress in patients with bicuspid aortic valve using phase-contrast MRI
    • Barker AJ, Lanning C, Shandas R,. Quantification of hemodynamic wall shear stress in patients with bicuspid aortic valve using phase-contrast MRI. Ann Biomed Eng 2010; 38: 788-800.
    • (2010) Ann Biomed Eng , vol.38 , pp. 788-800
    • Barker, A.J.1    Lanning, C.2    Shandas, R.3
  • 98
    • 2642562107 scopus 로고    scopus 로고
    • Flow patterns in the aortic root and the aorta studied with time-resolved, 3-dimensional, phase-contrast magnetic resonance imaging: Implications for aortic valve-sparing surgery
    • Kvitting JP, Ebbers T, Wigstrom L, Engvall J, Olin CL, Bolger AF,. Flow patterns in the aortic root and the aorta studied with time-resolved, 3-dimensional, phase-contrast magnetic resonance imaging: implications for aortic valve-sparing surgery. J Thorac Cardiovasc Surg 2004; 127: 1602-1607.
    • (2004) J Thorac Cardiovasc Surg , vol.127 , pp. 1602-1607
    • Kvitting, J.P.1    Ebbers, T.2    Wigstrom, L.3    Engvall, J.4    Olin, C.L.5    Bolger, A.F.6
  • 99
    • 23044502989 scopus 로고    scopus 로고
    • Time-resolved three-dimensional magnetic resonance velocity mapping of aortic flow in healthy volunteers and patients after valve-sparing aortic root replacement
    • Markl M, Draney MT, Miller DC, et al. Time-resolved three-dimensional magnetic resonance velocity mapping of aortic flow in healthy volunteers and patients after valve-sparing aortic root replacement. J Thorac Cardiovasc Surg 2005; 130: 456-463.
    • (2005) J Thorac Cardiovasc Surg , vol.130 , pp. 456-463
    • Markl, M.1    Draney, M.T.2    Miller, D.C.3
  • 102
    • 79955615202 scopus 로고    scopus 로고
    • Editorial. The role of hemodynamics in bicuspid aortic valve disease
    • Barker AJ, Markl M,. Editorial. The role of hemodynamics in bicuspid aortic valve disease. Eur J Cardiothorac Surg 2011; 39: 805-806.
    • (2011) Eur J Cardiothorac Surg , vol.39 , pp. 805-806
    • Barker, A.J.1    Markl, M.2
  • 103
    • 80054730003 scopus 로고    scopus 로고
    • Comparison of 4D flow parameters for quantification of flow eccentricity in the ascending aorta
    • Sigovan M, Hope MD, Dyverfeldt P, Saloner D,. Comparison of 4D flow parameters for quantification of flow eccentricity in the ascending aorta. J Magn Reson Imaging 2011; 34: 1226-1230.
    • (2011) J Magn Reson Imaging , vol.34 , pp. 1226-1230
    • Sigovan, M.1    Hope, M.D.2    Dyverfeldt, P.3    Saloner, D.4
  • 104
    • 79960331593 scopus 로고    scopus 로고
    • 4-dimensional flow cardiac magnetic resonance in assessment of valve-related ascending aortic disease
    • Hope MD, Hope TA, Crook SES, et al. 4-dimensional flow cardiac magnetic resonance in assessment of valve-related ascending aortic disease. JACC Cardiovascular Imaging 2011; 4: 781-787.
    • (2011) JACC Cardiovascular Imaging , vol.4 , pp. 781-787
    • Hope, M.D.1    Hope, T.A.2    Crook, S.E.S.3
  • 105
    • 77952528635 scopus 로고    scopus 로고
    • Hemodynamic predictors of aortic dilatation in bicuspid aortic valve by velocity-encoded cardiovascular magnetic resonance
    • den Reijer PM, Sallee D 3rd, van der Velden P, et al. Hemodynamic predictors of aortic dilatation in bicuspid aortic valve by velocity-encoded cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2010; 12: 4.
    • (2010) J Cardiovasc Magn Reson , vol.12 , pp. 4
    • Den Reijer, P.M.1    Sallee, D.2    Van Der Velden, P.3
  • 106
    • 0027972936 scopus 로고
    • Atherosclerotic disease of the aortic arch and the risk of ischemic stroke
    • Amarenco P, Cohen A, Tzourio C, et al. Atherosclerotic disease of the aortic arch and the risk of ischemic stroke. N Engl J Med 1994; 331: 1474-1479.
    • (1994) N Engl J Med , vol.331 , pp. 1474-1479
    • Amarenco, P.1    Cohen, A.2    Tzourio, C.3
  • 107
    • 34548119863 scopus 로고    scopus 로고
    • Aortic arch atheroma progression and recurrent vascular events in patients with stroke or transient ischemic attack
    • Sen S, Hinderliter A, Sen PK, et al. Aortic arch atheroma progression and recurrent vascular events in patients with stroke or transient ischemic attack. Circulation 2007; 116: 928-935.
    • (2007) Circulation , vol.116 , pp. 928-935
    • Sen, S.1    Hinderliter, A.2    Sen, P.K.3
  • 108
    • 33746233392 scopus 로고    scopus 로고
    • Aortic atherosclerotic disease and stroke
    • Kronzon I, Tunick PA,. Aortic atherosclerotic disease and stroke. Circulation 2006; 114: 63-75.
    • (2006) Circulation , vol.114 , pp. 63-75
    • Kronzon, I.1    Tunick, P.A.2
  • 109
    • 0030226094 scopus 로고    scopus 로고
    • Aortic flow velocity patterns in chronic aortic regurgitation: Implications for Doppler echocardiography
    • Reimold SC, Maier SE, Aggarwal K, et al. Aortic flow velocity patterns in chronic aortic regurgitation: implications for Doppler echocardiography. J Am Soc Echocardiogr 1996; 9: 675-683.
    • (1996) J Am Soc Echocardiogr , vol.9 , pp. 675-683
    • Reimold, S.C.1    Maier, S.E.2    Aggarwal, K.3
  • 110
    • 56149119010 scopus 로고    scopus 로고
    • Retrograde blood flow in the aortic arch determined by transesophageal Doppler ultrasound
    • Svedlund S, Wetterholm R, Volkmann R, Caidahl K,. Retrograde blood flow in the aortic arch determined by transesophageal Doppler ultrasound. Cerebrovasc Dis 2009; 27: 22-28.
    • (2009) Cerebrovasc Dis , vol.27 , pp. 22-28
    • Svedlund, S.1    Wetterholm, R.2    Volkmann, R.3    Caidahl, K.4
  • 111
    • 1842537978 scopus 로고    scopus 로고
    • Four-dimensional magnetic resonance velocity mapping of blood flow patterns in the aorta in patients with atherosclerotic coronary artery disease compared to age-matched normal subjects
    • Bogren HG, Buonocore MH, Valente RJ,. Four-dimensional magnetic resonance velocity mapping of blood flow patterns in the aorta in patients with atherosclerotic coronary artery disease compared to age-matched normal subjects. J Magn Reson Imaging 2004; 19: 417-427.
    • (2004) J Magn Reson Imaging , vol.19 , pp. 417-427
    • Bogren, H.G.1    Buonocore, M.H.2    Valente, R.J.3
  • 112
    • 77953133799 scopus 로고    scopus 로고
    • Complex plaques in the proximal descending aorta: An underestimated embolic source of stroke
    • Harloff A, Simon J, Brendecke S, et al. Complex plaques in the proximal descending aorta: an underestimated embolic source of stroke. Stroke 2010; 41: 1145-1150.
    • (2010) Stroke , vol.41 , pp. 1145-1150
    • Harloff, A.1    Simon, J.2    Brendecke, S.3
  • 113
    • 65249150706 scopus 로고    scopus 로고
    • Retrograde embolism from the descending aorta: Visualization by multidirectional 3D velocity mapping in cryptogenic stroke
    • Harloff A, Strecker C, Dudler P, et al. Retrograde embolism from the descending aorta: visualization by multidirectional 3D velocity mapping in cryptogenic stroke. Stroke 2009; 40: 1505-1508.
    • (2009) Stroke , vol.40 , pp. 1505-1508
    • Harloff, A.1    Strecker, C.2    Dudler, P.3
  • 114
    • 78751580683 scopus 로고    scopus 로고
    • Time-resolved three-dimensional magnetic resonance velocity mapping of cardiovascular flow paths in volunteers and patients with Fontan circulation
    • Markl M, Geiger J, Kilner PJ, et al. Time-resolved three-dimensional magnetic resonance velocity mapping of cardiovascular flow paths in volunteers and patients with Fontan circulation. Eur J Cardiothorac Surg 2011; 39: 206-212.
    • (2011) Eur J Cardiothorac Surg , vol.39 , pp. 206-212
    • Markl, M.1    Geiger, J.2    Kilner, P.J.3
  • 115
    • 34147223895 scopus 로고    scopus 로고
    • Pulmonary arterial hypertension: Noninvasive detection with phase-contrast MR imaging
    • Sanz J, Kuschnir P, Rius T, et al. Pulmonary arterial hypertension: noninvasive detection with phase-contrast MR imaging. Radiology 2007; 243: 70-79.
    • (2007) Radiology , vol.243 , pp. 70-79
    • Sanz, J.1    Kuschnir, P.2    Rius, T.3
  • 116
    • 0025102102 scopus 로고
    • Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cava
    • Kircher BJ, Himelman RB, Schiller NB,. Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cava. Am J Cardiol 1990; 66: 493-496.
    • (1990) Am J Cardiol , vol.66 , pp. 493-496
    • Kircher, B.J.1    Himelman, R.B.2    Schiller, N.B.3
  • 117
    • 70350465303 scopus 로고    scopus 로고
    • Utility of phase contrast MR imaging for assessment of pulmonary flow and pressure estimation in patients with pulmonary hypertension: Comparison with right heart catheterization and echocardiography
    • Nogami M, Ohno Y, Koyama H, et al. Utility of phase contrast MR imaging for assessment of pulmonary flow and pressure estimation in patients with pulmonary hypertension: comparison with right heart catheterization and echocardiography. J Magn Reson Imaging 2009; 30: 973-980.
    • (2009) J Magn Reson Imaging , vol.30 , pp. 973-980
    • Nogami, M.1    Ohno, Y.2    Koyama, H.3
  • 118
  • 119
    • 78650587630 scopus 로고    scopus 로고
    • Non-invasive assessment of transstenotic pressure gradients utilizing 3D phase contrast MRA: Validation against endovascular pressure measurements in a porcine study
    • Honolulu
    • Bley TA, Johnson KM, Wieben O, et al. Non-invasive assessment of transstenotic pressure gradients utilizing 3D phase contrast MRA: validation against endovascular pressure measurements in a porcine study. In: Proc 17th Annual Meeting ISMRM, Honolulu; 2009: 425.
    • (2009) Proc 17th Annual Meeting ISMRM , pp. 425
    • Bley, T.A.1    Johnson, K.M.2    Wieben, O.3
  • 120
    • 67649186010 scopus 로고    scopus 로고
    • Magnetic resonance-derived 3-dimensional blood flow patterns in the main pulmonary artery as a marker of pulmonary hypertension and a measure of elevated mean pulmonary arterial pressure
    • Reiter G, Reiter U, Kovacs G, et al. Magnetic resonance-derived 3-dimensional blood flow patterns in the main pulmonary artery as a marker of pulmonary hypertension and a measure of elevated mean pulmonary arterial pressure. Circ Cardiovasc Imaging 2008; 1: 23-30.
    • (2008) Circ Cardiovasc Imaging , vol.1 , pp. 23-30
    • Reiter, G.1    Reiter, U.2    Kovacs, G.3
  • 121
    • 79958251978 scopus 로고    scopus 로고
    • Early onset of retrograde flow in the main pulmonary artery is a characteristic of pulmonary arterial hypertension
    • Helderman F, Mauritz GJ, Andringa KE, Vonk-Noordegraaf A, Marcus JT,. Early onset of retrograde flow in the main pulmonary artery is a characteristic of pulmonary arterial hypertension. J Magn Reson Imaging 2011; 33: 1362-1368.
    • (2011) J Magn Reson Imaging , vol.33 , pp. 1362-1368
    • Helderman, F.1    Mauritz, G.J.2    Andringa, K.E.3    Vonk-Noordegraaf, A.4    Marcus, J.T.5
  • 122
    • 79953304124 scopus 로고    scopus 로고
    • Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance
    • Markl M, Kilner PJ, Ebbers T,. Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2011; 13: 7.
    • (2011) J Cardiovasc Magn Reson , vol.13 , pp. 7
    • Markl, M.1    Kilner, P.J.2    Ebbers, T.3
  • 123
    • 0028997082 scopus 로고
    • Left ventricular blood flow patterns in normal subjects: A quantitative analysis by three-dimensional magnetic resonance velocity mapping
    • Kim WY, Walker PG, Pedersen EM, et al. Left ventricular blood flow patterns in normal subjects: a quantitative analysis by three-dimensional magnetic resonance velocity mapping. J Am Coll Cardiol 1995; 26: 224-238.
    • (1995) J Am Coll Cardiol , vol.26 , pp. 224-238
    • Kim, W.Y.1    Walker, P.G.2    Pedersen, E.M.3
  • 125
    • 34648815779 scopus 로고    scopus 로고
    • Transit of blood flow through the human left ventricle mapped by cardiovascular magnetic resonance
    • Bolger AF, Heiberg E, Karlsson M, et al. Transit of blood flow through the human left ventricle mapped by cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2007; 9: 741-747.
    • (2007) J Cardiovasc Magn Reson , vol.9 , pp. 741-747
    • Bolger, A.F.1    Heiberg, E.2    Karlsson, M.3
  • 126
    • 77951904405 scopus 로고    scopus 로고
    • Passing strange: Flow in the failing ventricle
    • Carlhall CJ, Bolger A,. Passing strange: flow in the failing ventricle. Circ Heart Fail 2010; 3: 326-331.
    • (2010) Circ Heart Fail , vol.3 , pp. 326-331
    • Carlhall, C.J.1    Bolger, A.2
  • 127
    • 58149188386 scopus 로고    scopus 로고
    • Mitral valve and tricuspid valve blood flow: Accurate quantification with 3D velocity-encoded MR imaging with retrospective valve tracking
    • Westenberg JJ, Roes SD, Ajmone Marsan N, et al. Mitral valve and tricuspid valve blood flow: accurate quantification with 3D velocity-encoded MR imaging with retrospective valve tracking. Radiology 2008; 249: 792-800.
    • (2008) Radiology , vol.249 , pp. 792-800
    • Westenberg, J.J.1    Roes, S.D.2    Ajmone Marsan, N.3
  • 128
    • 79953883564 scopus 로고    scopus 로고
    • Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping
    • Toger J, Carlsson M, Soderlind G, Arheden H, Heiberg E,. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping. BMC Med Imaging 2011; 11: 10.
    • (2011) BMC Med Imaging , vol.11 , pp. 10
    • Toger, J.1    Carlsson, M.2    Soderlind, G.3    Arheden, H.4    Heiberg, E.5
  • 129
    • 80052650900 scopus 로고    scopus 로고
    • 4D-MR flow analysis in patients after repair for tetralogy of Fallot
    • Geiger J, Markl M, Jung B, et al. 4D-MR flow analysis in patients after repair for tetralogy of Fallot. Eur Radiol 2011; 21: 1651-1657.
    • (2011) Eur Radiol , vol.21 , pp. 1651-1657
    • Geiger, J.1    Markl, M.2    Jung, B.3
  • 130
    • 33646795941 scopus 로고    scopus 로고
    • Clinical evaluation of magnetic resonance imaging flowmetry of portal and hepatic veins in patients following hepatectomy
    • Nanashima A, Shibasaki S, Sakamoto I, et al. Clinical evaluation of magnetic resonance imaging flowmetry of portal and hepatic veins in patients following hepatectomy. Liver Int 2006; 26: 587-594.
    • (2006) Liver Int , vol.26 , pp. 587-594
    • Nanashima, A.1    Shibasaki, S.2    Sakamoto, I.3
  • 131
    • 0027499632 scopus 로고
    • Blood flow in the portal vein: Velocity quantitation with phase-contrast MR angiography
    • Applegate GR, Thaete FL, Meyers SP, et al. Blood flow in the portal vein: velocity quantitation with phase-contrast MR angiography. Radiology 1993; 187: 253-256.
    • (1993) Radiology , vol.187 , pp. 253-256
    • Applegate, G.R.1    Thaete, F.L.2    Meyers, S.P.3
  • 132
    • 0027258288 scopus 로고
    • Volumetric flow rates in the portal venous system: Measurement with cine phase-contrast MR imaging
    • Burkart DJ, Johnson CD, Morton MJ, Wolf RL, Ehman RL,. Volumetric flow rates in the portal venous system: measurement with cine phase-contrast MR imaging. AJR Am J Roentgenol 1993; 160: 1113-1118.
    • (1993) AJR Am J Roentgenol , vol.160 , pp. 1113-1118
    • Burkart, D.J.1    Johnson, C.D.2    Morton, M.J.3    Wolf, R.L.4    Ehman, R.L.5
  • 133
    • 0025122978 scopus 로고
    • Two- and three-dimensional phase contrast MR angiography of the abdomen
    • Dumoulin CL, Yucel EK, Vock P, et al. Two- and three-dimensional phase contrast MR angiography of the abdomen. J Comput Assist Tomogr 1990; 14: 779-784.
    • (1990) J Comput Assist Tomogr , vol.14 , pp. 779-784
    • Dumoulin, C.L.1    Yucel, E.K.2    Vock, P.3
  • 134
    • 0029002202 scopus 로고
    • Portal blood flow in the presence or absence of diffuse liver disease: Measurement by phase contrast MR imaging
    • Kashitani N, Kimoto S, Tsunoda M, et al. Portal blood flow in the presence or absence of diffuse liver disease: measurement by phase contrast MR imaging. Abdom Imaging 1995; 20: 197-200.
    • (1995) Abdom Imaging , vol.20 , pp. 197-200
    • Kashitani, N.1    Kimoto, S.2    Tsunoda, M.3
  • 135
    • 0028965067 scopus 로고
    • Evaluation of the portal venous system before liver transplantation: Value of phase-contrast MR angiography
    • Nghiem HV, Winter TC 3rd, Mountford MC, et al. Evaluation of the portal venous system before liver transplantation: value of phase-contrast MR angiography. AJR Am J Roentgenol 1995; 164: 871-878.
    • (1995) AJR Am J Roentgenol , vol.164 , pp. 871-878
    • Nghiem, H.V.1    Winter, T.C.2    Mountford, M.C.3
  • 136
    • 0032758126 scopus 로고    scopus 로고
    • Portal venous blood flow while breath-holding after inspiration or expiration and during normal respiration in controls and cirrhotics
    • Sugano S, Yamamoto K, Sasao K, Watanabe M,. Portal venous blood flow while breath-holding after inspiration or expiration and during normal respiration in controls and cirrhotics. J Gastroenterol 1999; 34: 613-618.
    • (1999) J Gastroenterol , vol.34 , pp. 613-618
    • Sugano, S.1    Yamamoto, K.2    Sasao, K.3    Watanabe, M.4
  • 137
    • 0032973449 scopus 로고    scopus 로고
    • Pharmacologically stimulated portal flow measurement by magnetic resonance imaging for assessment of liver function
    • Nakano S, Katoh T, Ohki M, et al. Pharmacologically stimulated portal flow measurement by magnetic resonance imaging for assessment of liver function. Radiat Med 1999; 17: 21-26.
    • (1999) Radiat Med , vol.17 , pp. 21-26
    • Nakano, S.1    Katoh, T.2    Ohki, M.3
  • 138
    • 77955345512 scopus 로고    scopus 로고
    • MR-based visualization and quantification of three-dimensional flow characteristics in the portal venous system
    • Stankovic Z, Frydrychowicz A, Csatari Z, et al. MR-based visualization and quantification of three-dimensional flow characteristics in the portal venous system. J Magn Reson Imaging 2010; 32: 466-475.
    • (2010) J Magn Reson Imaging , vol.32 , pp. 466-475
    • Stankovic, Z.1    Frydrychowicz, A.2    Csatari, Z.3
  • 139
    • 84876085091 scopus 로고    scopus 로고
    • Time-resolved qualitative and quantitative analysis of normal and altered 3D portal venous hemodynamics in liver cirrhosis patients
    • in press.
    • Stankovic Z, Csatari Z, Deibert P, et al. Time-resolved qualitative and quantitative analysis of normal and altered 3D portal venous hemodynamics in liver cirrhosis patients. Radiology 2012, in press.
    • (2012) Radiology
    • Stankovic, Z.1    Csatari, Z.2    Deibert, P.3
  • 140
    • 0028854765 scopus 로고
    • Three-point phase-contrast velocity measurements with increased velocity-to-noise ratio
    • Lee AT, Pike GB, Pelc NJ,. Three-point phase-contrast velocity measurements with increased velocity-to-noise ratio. Magn Reson Med 1995; 33: 122-126.
    • (1995) Magn Reson Med , vol.33 , pp. 122-126
    • Lee, A.T.1    Pike, G.B.2    Pelc, N.J.3
  • 142
    • 0028069564 scopus 로고
    • Renal artery stenosis: A common and important problem in patients with peripheral vascular disease
    • Missouris CG, Buckenham T, Cappuccio FP, MacGregor GA,. Renal artery stenosis: a common and important problem in patients with peripheral vascular disease. Am J Med 1994; 96: 10-14.
    • (1994) Am J Med , vol.96 , pp. 10-14
    • Missouris, C.G.1    Buckenham, T.2    Cappuccio, F.P.3    MacGregor, G.A.4
  • 143
    • 0034876086 scopus 로고    scopus 로고
    • Determination of renal arterial stenosis severity: Comparison of pressure gradient and vessel diameter
    • Gross CM, Kramer J, Weingartner O, et al. Determination of renal arterial stenosis severity: comparison of pressure gradient and vessel diameter. Radiology 2001; 220: 751-756.
    • (2001) Radiology , vol.220 , pp. 751-756
    • Gross, C.M.1    Kramer, J.2    Weingartner, O.3
  • 145
    • 0030893638 scopus 로고    scopus 로고
    • Renal artery stenosis: Grading of hemodynamic changes with cine phase-contrast MR blood flow measurements
    • Schoenberg SO, Knopp MV, Bock M, et al. Renal artery stenosis: grading of hemodynamic changes with cine phase-contrast MR blood flow measurements. Radiology 1997; 203: 45-53.
    • (1997) Radiology , vol.203 , pp. 45-53
    • Schoenberg, S.O.1    Knopp, M.V.2    Bock, M.3
  • 147
    • 60349117395 scopus 로고    scopus 로고
    • 3D blood flow characteristics in the carotid artery bifurcation assessed by flow-sensitive 4D MRI at 3T
    • Harloff A, Albrecht F, Spreer J, et al. 3D blood flow characteristics in the carotid artery bifurcation assessed by flow-sensitive 4D MRI at 3T. Magn Reson Med 2009; 61: 65-74.
    • (2009) Magn Reson Med , vol.61 , pp. 65-74
    • Harloff, A.1    Albrecht, F.2    Spreer, J.3
  • 148
    • 49849096590 scopus 로고    scopus 로고
    • Geometry of the carotid bifurcation predicts its exposure to disturbed flow
    • Lee SW, Antiga L, Spence JD, Steinman DA,. Geometry of the carotid bifurcation predicts its exposure to disturbed flow. Stroke 2008; 39: 2341-2347.
    • (2008) Stroke , vol.39 , pp. 2341-2347
    • Lee, S.W.1    Antiga, L.2    Spence, J.D.3    Steinman, D.A.4
  • 149
    • 0033485806 scopus 로고    scopus 로고
    • Hemodynamic shear stress and its role in atherosclerosis
    • Malek AM, Alper SL, Izumo S,. Hemodynamic shear stress and its role in atherosclerosis. JAMA 1999; 282: 2035-2042.
    • (1999) JAMA , vol.282 , pp. 2035-2042
    • Malek, A.M.1    Alper, S.L.2    Izumo, S.3
  • 150
    • 33745433110 scopus 로고    scopus 로고
    • Atherosclerotic lesion size and vulnerability are determined by patterns of fluid shear stress
    • Cheng C, Tempel D, van Haperen R, et al. Atherosclerotic lesion size and vulnerability are determined by patterns of fluid shear stress. Circulation 2006; 113: 2744-2753.
    • (2006) Circulation , vol.113 , pp. 2744-2753
    • Cheng, C.1    Tempel, D.2    Van Haperen, R.3
  • 151
    • 33846158142 scopus 로고    scopus 로고
    • Time-resolved 3D quantitative flow MRI of the major intracranial vessels: Initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging
    • Bammer R, Hope TA, Aksoy M, Alley MT,. Time-resolved 3D quantitative flow MRI of the major intracranial vessels: initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging. Magn Reson Med 2007; 57: 127-140.
    • (2007) Magn Reson Med , vol.57 , pp. 127-140
    • Bammer, R.1    Hope, T.A.2    Aksoy, M.3    Alley, M.T.4
  • 152
    • 33947611614 scopus 로고    scopus 로고
    • In vivo assessment and visualization of intracranial arterial hemodynamics with flow-sensitized 4D MR imaging at 3T
    • Wetzel S, Meckel S, Frydrychowicz A, et al. In vivo assessment and visualization of intracranial arterial hemodynamics with flow-sensitized 4D MR imaging at 3T. AJNR Am J Neuroradiol 2007; 28: 433-438.
    • (2007) AJNR Am J Neuroradiol , vol.28 , pp. 433-438
    • Wetzel, S.1    Meckel, S.2    Frydrychowicz, A.3
  • 153
    • 33847671800 scopus 로고    scopus 로고
    • Visualization of hemodynamics in intracranial arteries using time-resolved three-dimensional phase-contrast MRI
    • Yamashita S, Isoda H, Hirano M, et al. Visualization of hemodynamics in intracranial arteries using time-resolved three-dimensional phase-contrast MRI. J Magn Reson Imaging 2007; 25: 473-478.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 473-478
    • Yamashita, S.1    Isoda, H.2    Hirano, M.3
  • 154
    • 44649088998 scopus 로고    scopus 로고
    • In vivo visualization and analysis of 3-D hemodynamics in cerebral aneurysms with flow-sensitized 4-D MR imaging at 3 T
    • Meckel S, Stalder AF, Santini F, et al. In vivo visualization and analysis of 3-D hemodynamics in cerebral aneurysms with flow-sensitized 4-D MR imaging at 3 T. Neuroradiology 2008; 50: 473-484.
    • (2008) Neuroradiology , vol.50 , pp. 473-484
    • Meckel, S.1    Stalder, A.F.2    Santini, F.3
  • 155
    • 77956761517 scopus 로고    scopus 로고
    • Flow residence time and regions of intraluminal thrombus deposition in intracranial aneurysms
    • Rayz VL, Boussel L, Ge L, et al. Flow residence time and regions of intraluminal thrombus deposition in intracranial aneurysms. Ann Biomed Eng 2010; 38: 3058-3069.
    • (2010) Ann Biomed Eng , vol.38 , pp. 3058-3069
    • Rayz, V.L.1    Boussel, L.2    Ge, L.3
  • 156
    • 71049160437 scopus 로고    scopus 로고
    • Evaluation of intracranial stenoses and aneurysms with accelerated 4D flow
    • Hope TA, Hope MD, Purcell DD, et al. Evaluation of intracranial stenoses and aneurysms with accelerated 4D flow. Magn Reson Imaging 2010; 28: 41-46.
    • (2010) Magn Reson Imaging , vol.28 , pp. 41-46
    • Hope, T.A.1    Hope, M.D.2    Purcell, D.D.3
  • 157
    • 60549086615 scopus 로고    scopus 로고
    • Phase-contrast magnetic resonance imaging measurements in intracranial aneurysms in vivo of flow patterns, velocity fields, and wall shear stress: Comparison with computational fluid dynamics
    • Boussel L, Rayz V, Martin A, et al. Phase-contrast magnetic resonance imaging measurements in intracranial aneurysms in vivo of flow patterns, velocity fields, and wall shear stress: comparison with computational fluid dynamics. Magn Reson Med 2009; 61: 409-417.
    • (2009) Magn Reson Med , vol.61 , pp. 409-417
    • Boussel, L.1    Rayz, V.2    Martin, A.3
  • 158
    • 77957596972 scopus 로고    scopus 로고
    • In vivo hemodynamic analysis of intracranial aneurysms obtained by magnetic resonance fluid dynamics (MRFD) based on time-resolved three-dimensional phase-contrast MRI
    • Isoda H, Ohkura Y, Kosugi T, et al. In vivo hemodynamic analysis of intracranial aneurysms obtained by magnetic resonance fluid dynamics (MRFD) based on time-resolved three-dimensional phase-contrast MRI. Neuroradiology 2010; 52: 921-928.
    • (2010) Neuroradiology , vol.52 , pp. 921-928
    • Isoda, H.1    Ohkura, Y.2    Kosugi, T.3
  • 159
    • 55749113685 scopus 로고    scopus 로고
    • Aneurysm growth occurs at region of low wall shear stress: Patient-specific correlation of hemodynamics and growth in a longitudinal study
    • Boussel L, Rayz V, McCulloch C, et al. Aneurysm growth occurs at region of low wall shear stress: patient-specific correlation of hemodynamics and growth in a longitudinal study. Stroke 2008; 39: 2997-3002.
    • (2008) Stroke , vol.39 , pp. 2997-3002
    • Boussel, L.1    Rayz, V.2    McCulloch, C.3
  • 160
    • 0034145620 scopus 로고    scopus 로고
    • Improved peripheral MRA using multi-velocity-encoding phase contrast-enhanced MRA techniques
    • Goyen M, Heuser LJ,. Improved peripheral MRA using multi-velocity- encoding phase contrast-enhanced MRA techniques. Acta Radiol 2000; 41: 139-141.
    • (2000) Acta Radiol , vol.41 , pp. 139-141
    • Goyen, M.1    Heuser, L.J.2
  • 162
    • 0028055088 scopus 로고
    • MR angiography of the pelvis with variable velocity encoding and a phased-array coil
    • Swan JS, Grist TM, Weber DM, Sproat IA, Wojtowycz MM,. MR angiography of the pelvis with variable velocity encoding and a phased-array coil. Radiology 1994; 190: 363-369.
    • (1994) Radiology , vol.190 , pp. 363-369
    • Swan, J.S.1    Grist, T.M.2    Weber, D.M.3    Sproat, I.A.4    Wojtowycz, M.M.5
  • 163
    • 0026859003 scopus 로고
    • MR angiography of lower-extremity arterial disease: Preliminary experience
    • Yucel EK, Dumoulin CL, Waltman AC,. MR angiography of lower-extremity arterial disease: preliminary experience. J Magn Reson Imaging 1992; 2: 303-309.
    • (1992) J Magn Reson Imaging , vol.2 , pp. 303-309
    • Yucel, E.K.1    Dumoulin, C.L.2    Waltman, A.C.3
  • 164
    • 0026213247 scopus 로고
    • MR imaging of poststenotic flow phenomena: Experimental studies
    • Krug B, Kugel H, Friedmann G, et al. MR imaging of poststenotic flow phenomena: experimental studies. J Magn Reson Imaging 1991; 1: 585-591.
    • (1991) J Magn Reson Imaging , vol.1 , pp. 585-591
    • Krug, B.1    Kugel, H.2    Friedmann, G.3
  • 166
    • 33644838349 scopus 로고    scopus 로고
    • Superficial femoral artery occlusive disease severity correlates with MR cine phase-contrast flow measurements
    • Mohajer K, Zhang H, Gurell D, et al. Superficial femoral artery occlusive disease severity correlates with MR cine phase-contrast flow measurements. J Magn Reson Imaging 2006; 23: 355-360.
    • (2006) J Magn Reson Imaging , vol.23 , pp. 355-360
    • Mohajer, K.1    Zhang, H.2    Gurell, D.3
  • 167
    • 0029948192 scopus 로고    scopus 로고
    • Quantitative blood flow measurements with cine phase-contrast MR imaging of subjects at rest and after exercise to assess peripheral vascular disease
    • Pena CS, McCauley TR, Price TB, Sumpio B, Gusberg RJ, Gore JC,. Quantitative blood flow measurements with cine phase-contrast MR imaging of subjects at rest and after exercise to assess peripheral vascular disease. AJR Am J Roentgenol 1996; 167: 153-157.
    • (1996) AJR Am J Roentgenol , vol.167 , pp. 153-157
    • Pena, C.S.1    McCauley, T.R.2    Price, T.B.3    Sumpio, B.4    Gusberg, R.J.5    Gore, J.C.6
  • 168
    • 34247857466 scopus 로고    scopus 로고
    • Visualization of iliac and proximal femoral artery hemodynamics using time-resolved 3D phase contrast MRI at 3T
    • Frydrychowicz A, Winterer JT, Zaitsev M, et al. Visualization of iliac and proximal femoral artery hemodynamics using time-resolved 3D phase contrast MRI at 3T. J Magn Reson Imaging 2007; 25: 1085-1092.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 1085-1092
    • Frydrychowicz, A.1    Winterer, J.T.2    Zaitsev, M.3
  • 169
    • 36248993022 scopus 로고    scopus 로고
    • Is there replacement for percentage stenosis in characterizing occlusive vascular disease?
    • Prince MR,. Is there replacement for percentage stenosis in characterizing occlusive vascular disease? Radiology 2007; 245: 617-618.
    • (2007) Radiology , vol.245 , pp. 617-618
    • Prince, M.R.1
  • 170
    • 0242385483 scopus 로고    scopus 로고
    • K-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • Tsao J, Boesiger P, Pruessmann KP,. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003; 50: 1031-1042.
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 171
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM,. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58: 1182-1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 172
    • 75749105811 scopus 로고    scopus 로고
    • 4D phase contrast MRI at 3 T: Effect of standard and blood-pool contrast agents on SNR, PC-MRA, and blood flow visualization
    • Bock J, Frydrychowicz A, Stalder AF, et al. 4D phase contrast MRI at 3 T: effect of standard and blood-pool contrast agents on SNR, PC-MRA, and blood flow visualization. Magn Reson Med 2010; 63: 330-338.
    • (2010) Magn Reson Med , vol.63 , pp. 330-338
    • Bock, J.1    Frydrychowicz, A.2    Stalder, A.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.