Volumn 6, Issue 4, 2004, Pages 785-792

Retrospective respiratory motion correction for navigated cine velocity mapping

Author keywords

Cine imaging; Coronary flow quantification; Respiratory motion correction

Indexed keywords

ARTICLE; ARTIFACT; BREATH HOLDING; BREATHING MECHANICS; CORONARY ARTERY BLOOD FLOW; DIAPHRAGM MOVEMENT; DIASTOLE; FEMALE; HEART CYCLE; HUMAN; HUMAN EXPERIMENT; IMAGE QUALITY; MALE; MATHEMATICAL MODEL; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; PRIORITY JOURNAL; VALIDATION PROCESS; VOLUNTEER;

EID: 11144300903     PISSN: 10976647     EISSN: None     Source Type: Journal    
DOI: 10.1081/JCMR-200036119     Document Type: Article
Times cited : (13)

References (17)
  • 1
    • 0031283439 scopus 로고    scopus 로고
    • Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion
    • Atkinson, D., Hill, D. L., Stoyle, P. N., Summers, P. E., Keevil, S. F. (1997). Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion. IEEE Trans. Med. Imag. 16:903-910.
    • (1997) IEEE Trans. Med. Imag. , vol.16 , pp. 903-910
    • Atkinson, D.1    Hill, D.L.2    Stoyle, P.N.3    Summers, P.E.4    Keevil, S.F.5
  • 2
    • 11144274050 scopus 로고    scopus 로고
    • Retrospective image correction combined with slice tracking for respiratory motion compensation
    • Atkinson, D., Kozerke, S., Razavi, R. (2003). Retrospective image correction combined with slice tracking for respiratory motion compensation. J. Cardiovasc. Magn. Reson. 5:270-271.
    • (2003) J. Cardiovasc. Magn. Reson. , vol.5 , pp. 270-271
    • Atkinson, D.1    Kozerke, S.2    Razavi, R.3
  • 3
    • 0031860874 scopus 로고    scopus 로고
    • Quantification of in-plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification
    • Hofman, M. B., Wickline, S. A., Lorenz, C. H. (1998). Quantification of in-plane motion of the coronary arteries during the cardiac cycle: implications for acquisition window duration for MR flow quantification. J. Magn. Reson. Imaging 8:568-576.
    • (1998) J. Magn. Reson. Imaging , vol.8 , pp. 568-576
    • Hofman, M.B.1    Wickline, S.A.2    Lorenz, C.H.3
  • 4
    • 0031784731 scopus 로고    scopus 로고
    • Limits to the accuracy of vessel diameter measurement in MR angiography
    • Hoogeveen, R. M., Bakker, C. J., Viergever, M. A. (1998). Limits to the accuracy of vessel diameter measurement in MR angiography. J. Magn. Reson. Imaging 8:1228-1235.
    • (1998) J. Magn. Reson. Imaging , vol.8 , pp. 1228-1235
    • Hoogeveen, R.M.1    Bakker, C.J.2    Viergever, M.A.3
  • 5
    • 0035091222 scopus 로고    scopus 로고
    • Motion artifact reduction and vessel enhancement for free-breathing navigator-gated coronary MRA using 3D k-space reordering
    • Huber, M. E., Hengesbach, D., Botnar, R. M., Kissinger, K. V., Boesiger, P., Manning, W. J., Stuber, M. (2001). Motion artifact reduction and vessel enhancement for free-breathing navigator-gated coronary MRA using 3D k-space reordering. Magn. Reson. Med. 45:645-652.
    • (2001) Magn. Reson. Med. , vol.45 , pp. 645-652
    • Huber, M.E.1    Hengesbach, D.2    Botnar, R.M.3    Kissinger, K.V.4    Boesiger, P.5    Manning, W.J.6    Stuber, M.7
  • 6
    • 0034006547 scopus 로고    scopus 로고
    • Phase ordering with automatic window selection (PAWS): A novel motion-resistant technique for 3D coronary imaging
    • Jhooti, P., Gatehouse, P. D., Keegan, J., Bunce, N. H., Taylor, A. M., Firmin, D. N. (2000). Phase ordering with automatic window selection (PAWS): a novel motion-resistant technique for 3D coronary imaging. Magn. Reson. Med. 43: 470-480.
    • (2000) Magn. Reson. Med. , vol.43 , pp. 470-480
    • Jhooti, P.1    Gatehouse, P.D.2    Keegan, J.3    Bunce, N.H.4    Taylor, A.M.5    Firmin, D.N.6
  • 8
    • 0033953459 scopus 로고    scopus 로고
    • Image metric-based correction (autocorrection) of motion effects: Analysis of image metrics
    • McGee, K. P., Manduca, A., Felmlee, J. P., Riederer, S. J., Ehman, R. L. (2000). Image metric-based correction (autocorrection) of motion effects: analysis of image metrics. J. Magn. Reson. Imaging 11:174-181.
    • (2000) J. Magn. Reson. Imaging , vol.11 , pp. 174-181
    • McGee, K.P.1    Manduca, A.2    Felmlee, J.P.3    Riederer, S.J.4    Ehman, R.L.5
  • 9
    • 0033000057 scopus 로고    scopus 로고
    • Noninvasive determination of coronary blood flow velocity with magnetic resonance imaging: Comparison of breath-hold and navigator techniques with intravascular ultrasound
    • Nagel, E., Bornstedt, A., Hug, J., Schnackenburg, B., Wellnhofer, E., Fleck, E. (1999). Noninvasive determination of coronary blood flow velocity with magnetic resonance imaging: comparison of breath-hold and navigator techniques with intravascular ultrasound. Magn. Reson. Med. 41:544-549.
    • (1999) Magn. Reson. Med. , vol.41 , pp. 544-549
    • Nagel, E.1    Bornstedt, A.2    Hug, J.3    Schnackenburg, B.4    Wellnhofer, E.5    Fleck, E.6
  • 10
    • 11144326423 scopus 로고    scopus 로고
    • Prediction and interpolation of motion states for real-time respiratory gating
    • Nehrke, K., Boernert, P., Boeck, J. C. (1999). Prediction and interpolation of motion states for real-time respiratory gating. Proc. 16th Annual Meeting ESMRMB. 167-168.
    • (1999) Proc. 16th Annual Meeting ESMRMB , pp. 167-168
    • Nehrke, K.1    Boernert, P.2    Boeck, J.C.3
  • 11
    • 0036135913 scopus 로고    scopus 로고
    • Impact of navigator timing on free-breathing submillimeter 3D coronary magnetic resonance angiography
    • Spuentrup, E., Manning, W. J., Botnar, R. M., Kissinger, K. V., Stuber, M. (2002). Impact of navigator timing on free-breathing submillimeter 3D coronary magnetic resonance angiography. Magn. Reson. Med. 47:196-201.
    • (2002) Magn. Reson. Med. , vol.47 , pp. 196-201
    • Spuentrup, E.1    Manning, W.J.2    Botnar, R.M.3    Kissinger, K.V.4    Stuber, M.5
  • 13
    • 0033301611 scopus 로고    scopus 로고
    • Calculation of a subject-specific adaptive motion-correction factor for improved real-time navigator echo-gated magnetic resonance coronary angiography
    • Taylor, A. M., Keegan, J., Jhooti, P., Firmin, D. N., Pennell, D. J. (1999). Calculation of a subject-specific adaptive motion-correction factor for improved real-time navigator echo-gated magnetic resonance coronary angiography. J. Cardiovasc. Magn. Reson. 1:131-138.
    • (1999) J. Cardiovasc. Magn. Reson. , vol.1 , pp. 131-138
    • Taylor, A.M.1    Keegan, J.2    Jhooti, P.3    Firmin, D.N.4    Pennell, D.J.5
  • 14
    • 0033961766 scopus 로고    scopus 로고
    • Retrospective adaptive motion correction for navigator-gated 3D coronary MR angiography
    • Wang, Y., Ehman, R. L. (2000). Retrospective adaptive motion correction for navigator-gated 3D coronary MR angiography. J. Magn. Reson. Imaging 11:208-214.
    • (2000) J. Magn. Reson. Imaging , vol.11 , pp. 208-214
    • Wang, Y.1    Ehman, R.L.2
  • 15
    • 0028929929 scopus 로고
    • Respiratory motion of the heart: Kinematics and the implications for the spatial resolution in coronary imaging
    • Wang, Y., Riederer, S. J., Ehman, R. L. (1995). Respiratory motion of the heart: kinematics and the implications for the spatial resolution in coronary imaging. Magn. Reson. Med. 33:713-719.
    • (1995) Magn. Reson. Med. , vol.33 , pp. 713-719
    • Wang, Y.1    Riederer, S.J.2    Ehman, R.L.3
  • 16
    • 0030026702 scopus 로고    scopus 로고
    • Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography
    • Wang, Y., Rossman, P. J., Grimm, R. C., Riederer, S. J., Ehman, R. L. (1996). Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. Radiology 198:55-60.
    • (1996) Radiology , vol.198 , pp. 55-60
    • Wang, Y.1    Rossman, P.J.2    Grimm, R.C.3    Riederer, S.J.4    Ehman, R.L.5
  • 17
    • 0030739762 scopus 로고    scopus 로고
    • Motion-adapted gating based on k-space weighting for reduction of respiratory motion artifacts
    • Weiger, M., Bornert, P., Proksa, R., Schaffter, T., Haase, A. (1997). Motion-adapted gating based on k-space weighting for reduction of respiratory motion artifacts. Magn. Reson. Med. 38:322-333.
    • (1997) Magn. Reson. Med. , vol.38 , pp. 322-333
    • Weiger, M.1    Bornert, P.2    Proksa, R.3    Schaffter, T.4    Haase, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.