Volumn 25, Issue 2, 2006, Pages 148-157

Generation and visualization of four-dimensional MR angiography data using an undersampled 3-D projection trajectory

Author keywords

Animation; Image reconstruction; Magnetic resonance imaging; Temporal filtering

Indexed keywords

ALGORITHMS; ANIMATION; IMAGE RECONSTRUCTION; MAGNETIC RESONANCE IMAGING; OPTICAL RESOLVING POWER; SIGNAL TO NOISE RATIO; SPATIAL VARIABLES CONTROL;

EID: 31644444335     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2005.861706     Document Type: Article
Times cited : (55)

References (32)
  • 1
    • 0029805810 scopus 로고    scopus 로고
    • Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector
    • J. P. Earls, N. M. Rofsky, D. R. DeCorato, G. A. Krinsky, and J. C. Weinreb, "Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: usefulness of a timing examination and MR power injector," Radiology, vol. 201, no. 3, pp. 705-710, 1996.
    • (1996) Radiology , vol.201 , Issue.3 , pp. 705-710
    • Earls, J.P.1    Rofsky, N.M.2    DeCorato, D.R.3    Krinsky, G.A.4    Weinreb, J.C.5
  • 2
    • 0031403950 scopus 로고    scopus 로고
    • Optimization of contrast timing for breath-hold three-dimensional MR angiography
    • T. F. Hany, G. C. McKinnon, D. A. Leung, T. Pfammatter, and J. F. Debatin, "Optimization of contrast timing for breath-hold three-dimensional MR angiography," J. Magn. Reson. Imag., vol. 7, no. 3, pp. 551-556, 1997.
    • (1997) J. Magn. Reson. Imag. , vol.7 , Issue.3 , pp. 551-556
    • Hany, T.F.1    McKinnon, G.C.2    Leung, D.A.3    Pfammatter, T.4    Debatin, J.F.5
  • 3
    • 0030893848 scopus 로고    scopus 로고
    • Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography
    • T. K. Foo, M. Saranathan, M. R. Prince, and T. L. Chenevert, "Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography," Radiology, vol. 203, no. 1, pp. 275-280, 1997.
    • (1997) Radiology , vol.203 , Issue.1 , pp. 275-280
    • Foo, T.K.1    Saranathan, M.2    Prince, M.R.3    Chenevert, T.L.4
  • 4
    • 0030770299 scopus 로고    scopus 로고
    • Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: Application to the renal arteries
    • A. H. Wilman, S. J. Riederer, B. F. King, J. P. Debbins, P. J. Rossman, and R. L. Ehman, "Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: application to the renal arteries," Radiology, vol. 205, no. 1, pp. 137-146, 1997.
    • (1997) Radiology , vol.205 , Issue.1 , pp. 137-146
    • Wilman, A.H.1    Riederer, S.J.2    King, B.F.3    Debbins, J.P.4    Rossman, P.J.5    Ehman, R.L.6
  • 5
    • 0034912645 scopus 로고    scopus 로고
    • Carotid bifurcation: Evaluation of time-resolved three-dimensional angiography
    • T. J. Carroll, F. R. Korosec, G. M. Petermann, T. M. Grist, and P. A. Turski, "Carotid bifurcation: evaluation of time-resolved three-dimensional angiography," Radiology, vol. 220, pp. 525-532, 2001.
    • (2001) Radiology , vol.220 , pp. 525-532
    • Carroll, T.J.1    Korosec, F.R.2    Petermann, G.M.3    Grist, T.M.4    Turski, P.A.5
  • 6
    • 0034836434 scopus 로고    scopus 로고
    • Contrast-enhanced, single-injection MRA with automated table movement compared to multi-injection, time-resolved CE 3D-MRA of the aorta and run-off vessels - Initial results
    • T. F. Hany, T. J. Carroll, R. A. Omary, E. Esparza-Coss, F. R. Korosec, C. A. Mistretta, and T. M. Grist, "Contrast-enhanced, single-injection MRA with automated table movement compared to multi-injection, time-resolved CE 3D-MRA of the aorta and run-off vessels - initial results," Radiology, vol. 221, pp. 266-273, 2001.
    • (2001) Radiology , vol.221 , pp. 266-273
    • Hany, T.F.1    Carroll, T.J.2    Omary, R.A.3    Esparza-Coss, E.4    Korosec, F.R.5    Mistretta, C.A.6    Grist, T.M.7
  • 7
    • 0036720426 scopus 로고    scopus 로고
    • Thorax: Low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution - Initial results
    • J. P. Finn, V. Baskaran, J. C. Carr, R. M. McCarthy, F. S. Pereles, R. Kroeker, and G. A. Laub, "Thorax: low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution - initial results," Radiology, vol. 224, no. 3, pp. 896-904, 2002.
    • (2002) Radiology , vol.224 , Issue.3 , pp. 896-904
    • Finn, J.P.1    Baskaran, V.2    Carr, J.C.3    McCarthy, R.M.4    Pereles, F.S.5    Kroeker, R.6    Laub, G.A.7
  • 9
    • 0029758290 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced 3D MR angiography
    • F. R. Korosec, R. Frayne, T. M. Grist, and C. A. Mistretta, "Time-resolved contrast-enhanced 3D MR angiography," Magn. Reson. Med., vol. 36, no. 3, pp. 345-351, 1996.
    • (1996) Magn. Reson. Med. , vol.36 , Issue.3 , pp. 345-351
    • Korosec, F.R.1    Frayne, R.2    Grist, T.M.3    Mistretta, C.A.4
  • 10
    • 0036319895 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory
    • A. V. Barger, W. F. Block, Y. Toropov, T. M. Grist, and C. A. Mistretta, "Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory "Magn. Reson. Med., vol. 48, pp. 297-305, 2002.
    • (2002) Magn. Reson. Med. , vol.48 , pp. 297-305
    • Barger, A.V.1    Block, W.F.2    Toropov, Y.3    Grist, T.M.4    Mistretta, C.A.5
  • 12
    • 0034007629 scopus 로고    scopus 로고
    • Reduced aliasing artifacts using variable-density k-space sampling trajectories
    • C. M. Tsai and D. G. Nishimura, "Reduced aliasing artifacts using variable-density k-space sampling trajectories," Magn. Reson. Med., vol. 43, pp. 452-458, 2000.
    • (2000) Magn. Reson. Med. , vol.43 , pp. 452-458
    • Tsai, C.M.1    Nishimura, D.G.2
  • 13
    • 0020619692 scopus 로고
    • Experimental simulation of ECG-gated heart scans with a small number of views
    • P. Joseph and J. Whitley, "Experimental simulation of ECG-gated heart scans with a small number of views," Med Phys, vol. 10, pp. 444-449, 1983.
    • (1983) Med Phys , vol.10 , pp. 444-449
    • Joseph, P.1    Whitley, J.2
  • 14
    • 0019377552 scopus 로고
    • True three-dimensional image reconstruction by nuclear magnetic resonance zeugmatography
    • C. M. Lai and P. C. Lauterbur, "True three-dimensional image reconstruction by nuclear magnetic resonance zeugmatography," Phys Med Biol, vol. 26, pp. 851-856, 1981.
    • (1981) Phys Med Biol , vol.26 , pp. 851-856
    • Lai, C.M.1    Lauterbur, P.C.2
  • 15
    • 7544250228 scopus 로고    scopus 로고
    • Using multiple half-echos to improve sampling efficiency and fat suppression in time-resolved MRA
    • Toronto, ON, Canada
    • E. K. Brodsky, A. Lu, F. J. Thornton, T. M. Grist, and W. F. Block, "Using multiple half-echos to improve sampling efficiency and fat suppression in time-resolved MRA," in Proc. ISMRM IIth Annu. Meeting, Toronto, ON, Canada, 2003, p. 322.
    • (2003) Proc. ISMRM IIth Annu. Meeting , pp. 322
    • Brodsky, E.K.1    Lu, A.2    Thornton, F.J.3    Grist, T.M.4    Block, W.F.5
  • 16
    • 14744296815 scopus 로고    scopus 로고
    • Rapid fat suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction
    • A. Lu, E. K. Brodsky, T. M. Grist, and W. F. Block, "Rapid fat suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction," Magn. Reson. Med., vol. 53, pp. 692-699, 2005.
    • (2005) Magn. Reson. Med. , vol.53 , pp. 692-699
    • Lu, A.1    Brodsky, E.K.2    Grist, T.M.3    Block, W.F.4
  • 17
    • 0029956707 scopus 로고    scopus 로고
    • Effects of polar sampling in kspace
    • M. L. Lauzon and B. K. Rutt, "Effects of polar sampling in kspace," Magn. Reson. Med., vol. 36, no. 6, pp. 940-949, 1996.
    • (1996) Magn. Reson. Med. , vol.36 , Issue.6 , pp. 940-949
    • Lauzon, M.L.1    Rutt, B.K.2
  • 18
    • 0031850913 scopus 로고    scopus 로고
    • Reduced circular field-of-view imaging
    • K. Scheffler and J. Hennig, "Reduced circular field-of-view imaging," Magn. Reson. Med., vol. 40, pp. 474-480, 1998.
    • (1998) Magn. Reson. Med. , vol.40 , pp. 474-480
    • Scheffler, K.1    Hennig, J.2
  • 19
    • 0022187595 scopus 로고
    • A fast sinc gridding algorithm for Fourier inversion in computer tomography
    • J. D. O'Sullivan, "A fast sinc gridding algorithm for Fourier inversion in computer tomography," IEEE Trans. Med. Imag., vol. MI-4, pp. 200-207, 1985.
    • (1985) IEEE Trans. Med. Imag. , vol.MI-4 , pp. 200-207
    • O'Sullivan, J.D.1
  • 20
    • 0032957342 scopus 로고    scopus 로고
    • Sampling density compensation in MRI: Rationale and an iterative numerical solution
    • J. G. Pipe and P. Menon, "Sampling density compensation in MRI: rationale and an iterative numerical solution "Magn. Reson. Med., vol. 41, pp. 179-186, 1999.
    • (1999) Magn. Reson. Med. , vol.41 , pp. 179-186
    • Pipe, J.G.1    Menon, P.2
  • 21
    • 0026219520 scopus 로고
    • Selection of a convolution function for Fourier inversion using gridding
    • Sep.
    • J. I. Jackson, C. H. Meyer, D. G. Nishimura, and A. Macovski, "Selection of a convolution function for Fourier inversion using gridding," IEEE Trans. Med. Imag., vol. 10, no. 3, pp. 473-478, Sep. 1991.
    • (1991) IEEE Trans. Med. Imag. , vol.10 , Issue.3 , pp. 473-478
    • Jackson, J.I.1    Meyer, C.H.2    Nishimura, D.G.3    Macovski, A.4
  • 22
    • 0034120692 scopus 로고    scopus 로고
    • Reconstructing MR images from undersampled data: Data-weighting considerations
    • J. G. Pipe, "Reconstructing MR images from undersampled data: data-weighting considerations," Magn. Reson. Med., vol. 43, pp. 867-875, 2000.
    • (2000) Magn. Reson. Med. , vol.43 , pp. 867-875
    • Pipe, J.G.1
  • 23
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
    • _, "Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging," Magn. Reson. Med., vol. 42, pp. 963-969, 1999.
    • (1999) Magn. Reson. Med. , vol.42 , pp. 963-969
  • 24
    • 0033646318 scopus 로고    scopus 로고
    • K-space weight imaged contrast (KWIC) for contrast manipulation in projection reconstruction MRI
    • H. K. Song and L. Dougherty, "K-space weight imaged contrast (KWIC) for contrast manipulation in projection reconstruction MRI," Magn. Reson. Med., vol. 44, pp. 825-832, 2000.
    • (2000) Magn. Reson. Med. , vol.44 , pp. 825-832
    • Song, H.K.1    Dougherty, L.2
  • 26
    • 0028803115 scopus 로고
    • Continuous radial data acquisition for dynamic MRI
    • V. Rasche, R. W. de Boer, D. Holz, and R. Proksa, "Continuous radial data acquisition for dynamic MRI," Magn. Reson. Med., vol. 34, pp. 754-761, 1995.
    • (1995) Magn. Reson. Med. , vol.34 , pp. 754-761
    • Rasche, V.1    De Boer, R.W.2    Holz, D.3    Proksa, R.4
  • 28
    • 5644300036 scopus 로고    scopus 로고
    • Interactive visualization of time-resolved Contrast-Enhanced Magnetic Resonance Angiography (CE-MRA)
    • Seattle
    • E. K. Brodsky and W. F. Block, "Interactive visualization of time-resolved Contrast-Enhanced Magnetic Resonance Angiography (CE-MRA)," in IEEE Visualization, Seattle, 2003.
    • (2003) IEEE Visualization
    • Brodsky, E.K.1    Block, W.F.2
  • 29
    • 0036787343 scopus 로고    scopus 로고
    • Coronary MRA with 3D undersampled projection reconstruction TrueFISP
    • A. C. Larson, O. P. Simonetti, and D. Li, "Coronary MRA with 3D undersampled projection reconstruction TrueFISP," Magn. Reson. Med., vol. 48, no. 4, pp. 594-601, 2002.
    • (2002) Magn. Reson. Med. , vol.48 , Issue.4 , pp. 594-601
    • Larson, A.C.1    Simonetti, O.P.2    Li, D.3
  • 30
    • 0742334051 scopus 로고    scopus 로고
    • Direct parallel imaging reconstruction of radially sampled data using GRAPPA with reduced shifts
    • Toronto, ON, Canada
    • M. A. Griswold, R. M. Heidemann, and P. M. Jacob, "Direct parallel imaging reconstruction of radially sampled data using GRAPPA with reduced shifts," in Proc. ISMRM 11th Annu. Meeting, Toronto, ON, Canada, 2003, p. 2349.
    • (2003) Proc. ISMRM 11th Annu. Meeting , pp. 2349
    • Griswold, M.A.1    Heidemann, R.M.2    Jacob, P.M.3
  • 32
    • 31644437212 scopus 로고    scopus 로고
    • Real-time 3D non-Cartesian phased-array contrast-enhanced MRA
    • Miami, FL
    • E. K. Brodsky, T. M. Grist, and W. F. Block, "Real-time 3D non-Cartesian phased-array contrast-enhanced MRA," in Proc. ISMRM 13th Annu. Meeting, Miami, FL, 2005, p. 379.
    • (2005) Proc. ISMRM 13th Annu. Meeting , pp. 379
    • Brodsky, E.K.1    Grist, T.M.2    Block, W.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.