메뉴 건너뛰기




Volumn 61, Issue 2, 2009, Pages 409-417

Phase-contrast magnetic resonance imaging measurements in intracranial aneurysms in vivo of flow patterns, velocity fields, and wall shear stress: Comparison with computational fluid dynamics

Author keywords

Computational fluid dynamics; Flow pattern; Intracranial aneurysm; Phase contrast mri; Wall shear stress

Indexed keywords

FLOW PATTERNS; MAGNETIC RESONANCE IMAGING; PARAMETER ESTIMATION; SATELLITES; SHEAR FLOW; SHEAR STRESS; TRANSPIRATION; VELOCITY;

EID: 60549086615     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21861     Document Type: Article
Times cited : (177)

References (33)
  • 3
    • 0032506614 scopus 로고    scopus 로고
    • Unruptured intracranial aneurysms-risk of rupture and risks of surgical intervention
    • Unruptured intracranial aneurysms-risk of rupture and risks of surgical intervention. N Engl J Med 1998;339:1725-1733.
    • (1998) N Engl J Med , vol.339 , pp. 1725-1733
  • 5
    • 2542576350 scopus 로고    scopus 로고
    • Is aspect ratio a reliable predictor of intracranial aneurysm rupture?
    • Nader-Sepahi A, Casimiro M, Sen J, Kitchen ND. Is aspect ratio a reliable predictor of intracranial aneurysm rupture? Neurosurgery 2004;54:1343-1347.
    • (2004) Neurosurgery , vol.54 , pp. 1343-1347
    • Nader-Sepahi, A.1    Casimiro, M.2    Sen, J.3    Kitchen, N.D.4
  • 6
    • 34249823676 scopus 로고    scopus 로고
    • Complex hemodynamics at the apex of an arterial bifurcation induces vascular remodeling resembling cerebral aneurysm initiation
    • Meng H, Wang Z, Hoi Y, Gao L, Metaxa E, Swartz DD, Kolega J. Complex hemodynamics at the apex of an arterial bifurcation induces vascular remodeling resembling cerebral aneurysm initiation. Stroke 2007;38:1924-1931.
    • (2007) Stroke , vol.38 , pp. 1924-1931
    • Meng, H.1    Wang, Z.2    Hoi, Y.3    Gao, L.4    Metaxa, E.5    Swartz, D.D.6    Kolega, J.7
  • 7
    • 7644241840 scopus 로고    scopus 로고
    • Magnitude and role of wall shear stress on cerebral aneurysm: Computational fluid dynamic study of 20 middle cerebral artery aneurysms
    • Shojima M, Oshima M, Takagi K, Torii R, Hayakawa M, Katada K, Morita A, Kirino T. Magnitude and role of wall shear stress on cerebral aneurysm: computational fluid dynamic study of 20 middle cerebral artery aneurysms. Stroke 2004;35:2500-2505.
    • (2004) Stroke , vol.35 , pp. 2500-2505
    • Shojima, M.1    Oshima, M.2    Takagi, K.3    Torii, R.4    Hayakawa, M.5    Katada, K.6    Morita, A.7    Kirino, T.8
  • 8
    • 0022341927 scopus 로고
    • Towards a concept of thrombosis in accelerated flow: Rheology, fluid dynamics, and biochemistry
    • Wurzinger LJ, Blasberg P, Schmid-Schonbein H. Towards a concept of thrombosis in accelerated flow: rheology, fluid dynamics, and biochemistry. Biorheology 1985;22:437-450.
    • (1985) Biorheology , vol.22 , pp. 437-450
    • Wurzinger, L.J.1    Blasberg, P.2    Schmid-Schonbein, H.3
  • 9
    • 0033485806 scopus 로고    scopus 로고
    • Hemodynamic shear stress and its role in atherosclerosis
    • Malek AM, Alper SL, Izumo S. Hemodynamic shear stress and its role in atherosclerosis. JAMA 1999;282:2035-2042.
    • (1999) JAMA , vol.282 , pp. 2035-2042
    • Malek, A.M.1    Alper, S.L.2    Izumo, S.3
  • 11
    • 0032448856 scopus 로고    scopus 로고
    • The combination of magnetic resonance angiography and computational fluid dynamics: A critical review
    • Long Q, Xu XY, Collins MW, Griffith TM, Bourne M. The combination of magnetic resonance angiography and computational fluid dynamics: a critical review. Crit Rev Biomed Eng 1998;26:227-274.
    • (1998) Crit Rev Biomed Eng , vol.26 , pp. 227-274
    • Long, Q.1    Xu, X.Y.2    Collins, M.W.3    Griffith, T.M.4    Bourne, M.5
  • 12
    • 17444424630 scopus 로고    scopus 로고
    • Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: Technique and sensitivity
    • Cebral JR, Castro MA, Appanaboyina S, Putman CM, Millan D, Frangi AF. Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: technique and sensitivity. IEEE Trans Med Imaging 2005;24:457-467.
    • (2005) IEEE Trans Med Imaging , vol.24 , pp. 457-467
    • Cebral, J.R.1    Castro, M.A.2    Appanaboyina, S.3    Putman, C.M.4    Millan, D.5    Frangi, A.F.6
  • 14
    • 0029964796 scopus 로고    scopus 로고
    • Temporally resolved 3D phase-contrast imaging
    • Wigstrom L, Sjoqvist L, Wranne B. Temporally resolved 3D phase-contrast imaging. Magn Reson Med 1996;36:800-803.
    • (1996) Magn Reson Med , vol.36 , pp. 800-803
    • Wigstrom, L.1    Sjoqvist, L.2    Wranne, B.3
  • 16
    • 3343019140 scopus 로고    scopus 로고
    • Time-resolved 3-dimensional velocity mapping in the thoracic aorta: Visualization of 3-directional blood flow patterns in healthy volunteers and patients
    • Markl M, Draney MT, Hope MD, Levin JM, Chan FP, Alley MT, Pelc NJ, Herfkens RJ. Time-resolved 3-dimensional velocity mapping in the thoracic aorta: visualization of 3-directional blood flow patterns in healthy volunteers and patients. J Comput Assist Tomogr 2004;28:459-468.
    • (2004) J Comput Assist Tomogr , vol.28 , pp. 459-468
    • Markl, M.1    Draney, M.T.2    Hope, M.D.3    Levin, J.M.4    Chan, F.P.5    Alley, M.T.6    Pelc, N.J.7    Herfkens, R.J.8
  • 17
    • 37349004799 scopus 로고    scopus 로고
    • Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping
    • Hope TA, Markl M, Wigstrom L, Alley MT, Miller DC, Herfkens RJ. Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping. J Magn Reson Imaging 2007;26:1471-1479.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 1471-1479
    • Hope, T.A.1    Markl, M.2    Wigstrom, L.3    Alley, M.T.4    Miller, D.C.5    Herfkens, R.J.6
  • 18
    • 2442677833 scopus 로고    scopus 로고
    • Intraaneurysmal flow visualization by using phase-contrast magnetic resonance imaging: Feasibility study based on a geometrically realistic in vitro aneurysm model
    • Tateshima S, Grinstead J, Sinha S, Nien YL, Murayama Y, Villablanca JP, Tanishita K, Vinuela F. Intraaneurysmal flow visualization by using phase-contrast magnetic resonance imaging: feasibility study based on a geometrically realistic in vitro aneurysm model. J Neurosurg 2004;100:1041-1048.
    • (2004) J Neurosurg , vol.100 , pp. 1041-1048
    • Tateshima, S.1    Grinstead, J.2    Sinha, S.3    Nien, Y.L.4    Murayama, Y.5    Villablanca, J.P.6    Tanishita, K.7    Vinuela, F.8
  • 19
    • 37349108181 scopus 로고    scopus 로고
    • Laser Doppler velocimetry (LDV) and 3D phase-contrast magnetic resonance angiography (PC-MRA) velocity measurements: Validation in an anatomically accurate cerebral artery aneurysm model with steady flow
    • Hollnagel DI, Summers PE, Kollias SS, Poulikakos D. Laser Doppler velocimetry (LDV) and 3D phase-contrast magnetic resonance angiography (PC-MRA) velocity measurements: validation in an anatomically accurate cerebral artery aneurysm model with steady flow. J Magn Reson Imaging 2007;26:1493-1505.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 1493-1505
    • Hollnagel, D.I.1    Summers, P.E.2    Kollias, S.S.3    Poulikakos, D.4
  • 21
    • 1842523994 scopus 로고    scopus 로고
    • MRI and CFD studies of pulsatile flow in healthy and stenosed carotid bifurcation models
    • Marshall I, Zhao S, Papathanasopoulou P, Hoskins P, Xu Y. MRI and CFD studies of pulsatile flow in healthy and stenosed carotid bifurcation models. J Biomech 2004;37:679-687.
    • (2004) J Biomech , vol.37 , pp. 679-687
    • Marshall, I.1    Zhao, S.2    Papathanasopoulou, P.3    Hoskins, P.4    Xu, Y.5
  • 24
    • 0035988856 scopus 로고    scopus 로고
    • Elastodynamics and arterial wall stress
    • Humphrey JD, Na S. Elastodynamics and arterial wall stress. Ann Biomed Eng 2002;30:509-523.
    • (2002) Ann Biomed Eng , vol.30 , pp. 509-523
    • Humphrey, J.D.1    Na, S.2
  • 25
    • 0034762955 scopus 로고    scopus 로고
    • MRI measurement of wall shear stress vectors in bifurcation models and comparison with CFD predictions
    • Kohler U, Marshall I, Robertson MB, Long Q, Xu XY, Hoskins PR. MRI measurement of wall shear stress vectors in bifurcation models and comparison with CFD predictions. J Magn Reson Imaging 2001;14:563-573.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 563-573
    • Kohler, U.1    Marshall, I.2    Robertson, M.B.3    Long, Q.4    Xu, X.Y.5    Hoskins, P.R.6
  • 27
    • 34249903866 scopus 로고    scopus 로고
    • Fluid- induced wall shear stress in anthropomorphic brain aneurysm models: MR phase-contrast study at 3 T
    • Ahn S, Shin D, Tateshima S, Tanishita K, Vinuela F, Sinha S. Fluid- induced wall shear stress in anthropomorphic brain aneurysm models: MR phase-contrast study at 3 T. J Magn Reson Imaging 2007;25:1120-1130.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 1120-1130
    • Ahn, S.1    Shin, D.2    Tateshima, S.3    Tanishita, K.4    Vinuela, F.5    Sinha, S.6
  • 28
    • 0033988427 scopus 로고    scopus 로고
    • Hemodynamics in the carotid artery bifurcation: A comparison between numerical simulations and in vitro MRI measurements
    • Botnar R, Rappitsch G, Scheidegger MB, Liepsch D, Perktold K, Boesiger P. Hemodynamics in the carotid artery bifurcation: a comparison between numerical simulations and in vitro MRI measurements. J Biomech 2000;33:137-144.
    • (2000) J Biomech , vol.33 , pp. 137-144
    • Botnar, R.1    Rappitsch, G.2    Scheidegger, M.B.3    Liepsch, D.4    Perktold, K.5    Boesiger, P.6
  • 30
    • 0036584937 scopus 로고    scopus 로고
    • Cardiovascular flow measurement with phase-contrast MR imaging: Basic facts and implementation
    • Lotz J, Meier C, Leppert A, Galanski M. Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. Radiographics 2002;22:651-671.
    • (2002) Radiographics , vol.22 , pp. 651-671
    • Lotz, J.1    Meier, C.2    Leppert, A.3    Galanski, M.4
  • 31
    • 34247275384 scopus 로고    scopus 로고
    • Intra- aneurysmal hemodynamics during the growth of an unruptured aneurysm: In vitro study using longitudinal CT angiogram database
    • Tateshima S, Tanishita K, Omura H, Villablanca JP, Vinuela F. Intra- aneurysmal hemodynamics during the growth of an unruptured aneurysm: in vitro study using longitudinal CT angiogram database. AJNR Am J Neuroradiol 2007;28:622-627.
    • (2007) AJNR Am J Neuroradiol , vol.28 , pp. 622-627
    • Tateshima, S.1    Tanishita, K.2    Omura, H.3    Villablanca, J.P.4    Vinuela, F.5
  • 32
    • 17844403299 scopus 로고    scopus 로고
    • In vitro validation of phase-contrast flow measurements at3Tincomparison to 1.5 T: Precision, accuracy, and signal-to-noise ratios
    • Lotz J, Doker R, Noeske R, Schuttert M, Felix R, Galanski M, Gutberlet M, Meyer GP. In vitro validation of phase-contrast flow measurements at3Tincomparison to 1.5 T: precision, accuracy, and signal-to-noise ratios. J Magn Reson Imaging 2005;21:604-610.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 604-610
    • Lotz, J.1    Doker, R.2    Noeske, R.3    Schuttert, M.4    Felix, R.5    Galanski, M.6    Gutberlet, M.7    Meyer, G.P.8
  • 33
    • 34548401674 scopus 로고    scopus 로고
    • Recent advances in contrast-enhanced magnetic resonance angiography
    • Meaney JF, Goyen M. Recent advances in contrast-enhanced magnetic resonance angiography. Eur Radiol 2007;17:2-6.
    • (2007) Eur Radiol , vol.17 , pp. 2-6
    • Meaney, J.F.1    Goyen, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.