메뉴 건너뛰기




Volumn 133, Issue 30, 2011, Pages 11605-11613

Catalytic mechanism of water oxidation with single-site ruthenium-heteropolytungstate complexes

Author keywords

[No Author keywords available]

Indexed keywords

ACTIVE SPECIES; CATALYTIC CYCLES; CATALYTIC INTERMEDIATES; CATALYTIC MECHANISMS; CATALYTIC REACTIVITY; COMPLEX 1; CYCLIC VOLTAMMETRIC MEASUREMENTS; HETEROPOLYTUNGSTATES; IN-SITU; KEGGIN-TYPE; KINETIC ANALYSIS; LACUNARY; ONE-ELECTRON OXIDANTS; OXO COMPLEXES; OXYGEN ATOM; POURBAIX DIAGRAM; RATE DETERMINING STEP; REDOX COUPLE; RESONANCE RAMAN; RUTHENIUM COMPLEXES; UV-VISIBLE ABSORPTION; VARIOUS PH; WATER OXIDATION;

EID: 79960878345     PISSN: 00027863     EISSN: 15205126     Source Type: Journal    
DOI: 10.1021/ja2024965     Document Type: Article
Times cited : (201)

References (116)
  • 4
  • 89
    • 50149121231 scopus 로고    scopus 로고
    • For the cobalt-based water oxidation catalysts, see
    • For the cobalt-based water oxidation catalysts, see: Kanan, M. W.; Nocera, D. G. Science 2008, 321, 1072
    • (2008) Science , vol.321 , pp. 1072
    • Kanan, M.W.1    Nocera, D.G.2
  • 95
    • 79960875781 scopus 로고    scopus 로고
    • The pH dependence of 1 with more limited pH region was reported in ref 44a.
    • The pH dependence of 1 with more limited pH region was reported in ref 44a.
  • 96
    • 84855684745 scopus 로고    scopus 로고
    • -1) resulted in the catalytic current for the water oxidation, which increases with increasing concentration of the catalyst (see Figure S6 in the Supporting Information).
    • -1) resulted in the catalytic current for the water oxidation, which increases with increasing concentration of the catalyst (see Figure S6 in the Supporting Information).
  • 101
    • 84855674202 scopus 로고    scopus 로고
    • -4 M) for the accurate determination of the rate constant.
    • -4 M) for the accurate determination of the rate constant.
  • 115
    • 84855674204 scopus 로고    scopus 로고
    • 3 (pH 1), and it was confirmed that neither the rate constant nor the pH of the solution was affected by the ionic strength.
    • 3 (pH 1), and it was confirmed that neither the rate constant nor the pH of the solution was affected by the ionic strength.
  • 116
    • 84855663935 scopus 로고    scopus 로고
    • a as well as the higher electrophilicity of the Ru metal center appropriate for the rate-determining nucleophilic attack of a water molecule to the Ru center.
    • a as well as the higher electrophilicity of the Ru metal center appropriate for the rate-determining nucleophilic attack of a water molecule to the Ru center.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.