메뉴 건너뛰기




Volumn 27, Issue 6, 2008, Pages 661-699

Orbitrap mass spectrometry: Instrumentation, ion motion and applications

Author keywords

Broadband AC dipolar excitation; Fourier transform; FT MS; High resolution; Hybrid spectrometer; Ion motion control; Ion trap; Mass accuracy; Orbitrap; Peak shape; Resolving power; Simulations

Indexed keywords

BROADBAND AC DIPOLAR EXCITATION; FT-MS; HIGH RESOLUTION; HYBRID SPECTROMETER; ION TRAP; MASS ACCURACY; ORBITRAP; PEAK SHAPE; RESOLVING POWER; SIMULATIONS;

EID: 57249091714     PISSN: 02777037     EISSN: None     Source Type: Journal    
DOI: 10.1002/mas.20186     Document Type: Article
Times cited : (366)

References (240)
  • 1
    • 33750364830 scopus 로고    scopus 로고
    • The human urinary proteome contains more than 1500 proteins, including a large proportion of membrane proteins
    • Adachi J, Kumar C, Zhang Y, Olsen JV, Mann M. 2006. The human urinary proteome contains more than 1500 proteins, including a large proportion of membrane proteins. Genome Biol 7:R80.
    • (2006) Genome Biol , vol.7
    • Adachi, J.1    Kumar, C.2    Zhang, Y.3    Olsen, J.V.4    Mann, M.5
  • 2
    • 0035241690 scopus 로고    scopus 로고
    • Mass spectrometry in proteomics
    • Aebersold R, Goodlett DR. 2001. Mass spectrometry in proteomics. Chem Rev 101:269-295.
    • (2001) Chem Rev , vol.101 , pp. 269-295
    • Aebersold, R.1    Goodlett, D.R.2
  • 3
    • 0037435030 scopus 로고    scopus 로고
    • Mass spectrometry-based proteomics
    • Aebersold R, Mann M. 2003. Mass spectrometry-based proteomics. Nature 422:198-207.
    • (2003) Nature , vol.422 , pp. 198-207
    • Aebersold, R.1    Mann, M.2
  • 4
    • 0003041446 scopus 로고    scopus 로고
    • Alfred RL, Londry FA, March RE. 1993. Resonance excitation of ions stored in a quadrupole ion trap. Part IV. Theory of quadrupolar excitation. Int J Mass Spectrom Ion Processes 1.25:171-185.
    • Alfred RL, Londry FA, March RE. 1993. Resonance excitation of ions stored in a quadrupole ion trap. Part IV. Theory of quadrupolar excitation. Int J Mass Spectrom Ion Processes 1.25:171-185.
  • 5
    • 0001126556 scopus 로고    scopus 로고
    • Fourier transform detection in a cylindrical quadrupole ion trap
    • Badman ER, Wells JM, Bui HA, Cooks RG. 1998. Fourier transform detection in a cylindrical quadrupole ion trap. Anal Chem 70:3545-3547.
    • (1998) Anal Chem , vol.70 , pp. 3545-3547
    • Badman, E.R.1    Wells, J.M.2    Bui, H.A.3    Cooks, R.G.4
  • 6
    • 0032795896 scopus 로고    scopus 로고
    • Differential non-destructive image current detection in a Fourier transform quadrupole ion trap
    • Badman ER, Patterson GE, Wells JM, Santini RE, Cooks RG. 1999. Differential non-destructive image current detection in a Fourier transform quadrupole ion trap. J Mass Spectrom 34:889-894.
    • (1999) J Mass Spectrom , vol.34 , pp. 889-894
    • Badman, E.R.1    Patterson, G.E.2    Wells, J.M.3    Santini, R.E.4    Cooks, R.G.5
  • 7
    • 33845960593 scopus 로고    scopus 로고
    • Challenges and achievements of LC-MS in environmental analysis: 25 years on
    • Barceló D, Petrovic M. 2007. Challenges and achievements of LC-MS in environmental analysis: 25 years on. Trends Anal Chem 26:2-11.
    • (2007) Trends Anal Chem , vol.26 , pp. 2-11
    • Barceló, D.1    Petrovic, M.2
  • 8
    • 0034657819 scopus 로고    scopus 로고
    • Zeptomole-sensitivity electrospray ionization-Fourier transform, ion cyclotron resonance mass spectrometry of proteins
    • Belov ME, Gorshkov MV, Udseth HR, Anderson GA, Smith RD. 2000. Zeptomole-sensitivity electrospray ionization-Fourier transform, ion cyclotron resonance mass spectrometry of proteins. Anal. Chem 72:2271-2279.
    • (2000) Anal. Chem , vol.72 , pp. 2271-2279
    • Belov, M.E.1    Gorshkov, M.V.2    Udseth, H.R.3    Anderson, G.A.4    Smith, R.D.5
  • 9
    • 33751094563 scopus 로고    scopus 로고
    • Direct high-resolution peptide and protein analysis by desorption electrospray ionization. Fourier transform ion cyclotron resonance mass spectrometry
    • Bereman MS, Nyadong L, Fernandez FM, Muddiman DC. 2006. Direct high-resolution peptide and protein analysis by desorption electrospray ionization. Fourier transform ion cyclotron resonance mass spectrometry. Rapid Commun Mass Spectrom. 20:3409-3411.
    • (2006) Rapid Commun Mass Spectrom , vol.20 , pp. 3409-3411
    • Bereman, M.S.1    Nyadong, L.2    Fernandez, F.M.3    Muddiman, D.C.4
  • 10
    • 0025670535 scopus 로고
    • Sequencing of peptides by tandem mass spectrometry and high-energy collision-induced dissociation
    • Biemann K. 1990. Sequencing of peptides by tandem mass spectrometry and high-energy collision-induced dissociation. Method Enzymol 193:455-479.
    • (1990) Method Enzymol , vol.193 , pp. 455-479
    • Biemann, K.1
  • 11
    • 0023399896 scopus 로고
    • Characterization by tandem mass spectrometry of structural modifications in proteins
    • Biemann K, Scoble HA. 1987. Characterization by tandem mass spectrometry of structural modifications in proteins. Science 237:992-998.
    • (1987) Science , vol.237 , pp. 992-998
    • Biemann, K.1    Scoble, H.A.2
  • 14
    • 14744304574 scopus 로고    scopus 로고
    • Proteomics by FTICR mass spectrometry: Top down and bottom up
    • Bogdanov B, Smith RD. 2005. Proteomics by FTICR mass spectrometry: Top down and bottom up. Mass Spectrom. Rev 24:168-200.
    • (2005) Mass Spectrom. Rev , vol.24 , pp. 168-200
    • Bogdanov, B.1    Smith, R.D.2
  • 15
    • 39749149024 scopus 로고    scopus 로고
    • Quantification of human insulinlike growth factor-1 and qualitative detection of its analogues in plasma using liquid chromatography/electrospray ionization tandem, mass spectrometry
    • Bredehöft M, Schänzer W, Thevis M. 2008. Quantification of human insulinlike growth factor-1 and qualitative detection of its analogues in plasma using liquid chromatography/electrospray ionization tandem, mass spectrometry. Rapid Commun Mass Spectrom. 22:477-485.
    • (2008) Rapid Commun Mass Spectrom , vol.22 , pp. 477-485
    • Bredehöft, M.1    Schänzer, W.2    Thevis, M.3
  • 17
    • 33644839473 scopus 로고    scopus 로고
    • Accurate mass measurements for the determination of elemental formula - A. tutorial
    • Bristow AWT. 2006. Accurate mass measurements for the determination of elemental formula - A. tutorial. Mass Spectrom Rev 25:99-111.
    • (2006) Mass Spectrom Rev , vol.25 , pp. 99-111
    • Bristow, A.W.T.1
  • 18
    • 0002110673 scopus 로고
    • Mass-spectrometry with ion sources operating at atmospheric-pressure
    • Bruins AP. 1991, Mass-spectrometry with ion sources operating at atmospheric-pressure. Mass Spectrom Rev 10:53-77.
    • (1991) Mass Spectrom Rev , vol.10 , pp. 53-77
    • Bruins, A.P.1
  • 19
    • 57249106130 scopus 로고    scopus 로고
    • Busch KL, Glish GL, McLuckey SA. 1.988. Mass spectrometry/mass spectrometry: Techniques and applications of tandem mass spectrometry. New York: VCH.
    • Busch KL, Glish GL, McLuckey SA. 1.988. Mass spectrometry/mass spectrometry: Techniques and applications of tandem mass spectrometry. New York: VCH.
  • 22
    • 0000581317 scopus 로고
    • Radiative lifetimes of several metastable states of doubly and triply ionized Ar, Kr and Xe
    • Calamai AG, Johnson CE. 1992. Radiative lifetimes of several metastable states of doubly and triply ionized Ar, Kr and Xe. Phys Rev A: At Mol Opt Phys 45:7792-7799.
    • (1992) Phys Rev A: At Mol Opt Phys , vol.45 , pp. 7792-7799
    • Calamai, A.G.1    Johnson, C.E.2
  • 23
    • 0001192654 scopus 로고
    • Subprogram detection system for gas phase analysis based upon atmospheric pressure ionization (API) mass spectrometry
    • Carroll DI, Dzidic I, Still well RN, Horning MG, Horning EC. 1974. Subprogram detection system for gas phase analysis based upon atmospheric pressure ionization (API) mass spectrometry. Anal Chem 46:706-710.
    • (1974) Anal Chem , vol.46 , pp. 706-710
    • Carroll, D.I.1    Dzidic, I.2    Still well, R.N.3    Horning, M.G.4    Horning, E.C.5
  • 24
    • 0016596497 scopus 로고
    • Atmospheric pressure ionization mass spectrometry: Corona discharge ion source for use in liquid chromatograph-mass spectrometer-computer analytical system
    • Carroll DI, Dzidic I, Stillwell RN, Haegele KD, Horning EC. 1975. Atmospheric pressure ionization mass spectrometry: Corona discharge ion source for use in liquid chromatograph-mass spectrometer-computer analytical system. Anal Chem 47:2369-2373.
    • (1975) Anal Chem , vol.47 , pp. 2369-2373
    • Carroll, D.I.1    Dzidic, I.2    Stillwell, R.N.3    Haegele, K.D.4    Horning, E.C.5
  • 26
    • 34447313907 scopus 로고    scopus 로고
    • Structural identification of trace level enol tautomer impurity by on-line hydrogen/deuterium exchange HR-LC/MS in a LTQ-Orbitrap hybrid mass spectrometer
    • Chen GD, Khusid A, Daaro I, Irish P, Pramanik BN. 2007a. Structural identification of trace level enol tautomer impurity by on-line hydrogen/deuterium exchange HR-LC/MS in a LTQ-Orbitrap hybrid mass spectrometer. J Mass Spectrom 42:967-970.
    • (2007) J Mass Spectrom , vol.42 , pp. 967-970
    • Chen, G.D.1    Khusid, A.2    Daaro, I.3    Irish, P.4    Pramanik, B.N.5
  • 27
    • 33947249054 scopus 로고    scopus 로고
    • Applications of LC/MS in structure identifications of small molecules and proteins in drug discovery
    • Chen, GD, Pramanik, BN, Liu Y-H, Mirza UA. 2007b. Applications of LC/MS in structure identifications of small molecules and proteins in drug discovery. J Mass Spectrom 42:279-287.
    • (2007) J Mass Spectrom , vol.42 , pp. 279-287
    • Chen, G.D.1    Pramanik, B.N.2    Liu, Y.-H.3    Mirza, U.A.4
  • 28
    • 0001261026 scopus 로고
    • Stored waveform simultaneous mass-selective ejection/excitation for Fourier transform ion cyclotron resonance mass spectrometry
    • Chen L, Marshall AG. 1987. Stored waveform simultaneous mass-selective ejection/excitation for Fourier transform ion cyclotron resonance mass spectrometry. Int J Mass Spectrom Ion Processes 79:115-125.
    • (1987) Int J Mass Spectrom Ion Processes , vol.79 , pp. 115-125
    • Chen, L.1    Marshall, A.G.2
  • 29
    • 0000484001 scopus 로고    scopus 로고
    • Duty cycle improvement for a quadrupole-time-of- flight mass spectrometer and its use for precursor ion scans
    • Chernushevich IV. 2000. Duty cycle improvement for a quadrupole-time-of- flight mass spectrometer and its use for precursor ion scans. Eur J Mass Spectrom 6:471-479.
    • (2000) Eur J Mass Spectrom , vol.6 , pp. 471-479
    • Chernushevich, I.V.1
  • 30
    • 0034852208 scopus 로고    scopus 로고
    • An Introduction to quadrupole-time-of-flight mass spectrometry
    • Chernushevich IV, Loboda AV, Thomson BA. 2001. An Introduction to quadrupole-time-of-flight mass spectrometry. J Mass Spectrom 36:849-865.
    • (2001) J Mass Spectrom , vol.36 , pp. 849-865
    • Chernushevich, I.V.1    Loboda, A.V.2    Thomson, B.A.3
  • 31
    • 0000559280 scopus 로고
    • Collision measurements and excited-level lifetime measurements on ions stored in Paul, Penning and Kingdon ion traps
    • Church DA. 1993. Collision measurements and excited-level lifetime measurements on ions stored in Paul, Penning and Kingdon ion traps. Phys Rep 228:253-358.
    • (1993) Phys Rep , vol.228 , pp. 253-358
    • Church, D.A.1
  • 32
    • 4243366367 scopus 로고
    • Quenching collisions of low-energy metastable multiply charged argon ions
    • Church DA, Yang L, Tu S. 1994. Quenching collisions of low-energy metastable multiply charged argon ions. Phys Rev A: At Mol Opt Phys 50:3151-3156.
    • (1994) Phys Rev A: At Mol Opt Phys , vol.50 , pp. 3151-3156
    • Church, D.A.1    Yang, L.2    Tu, S.3
  • 33
    • 0008487740 scopus 로고    scopus 로고
    • Precision and accuracy of lifetimes of metastable levels using the Ringdon trap technique
    • Church DA, Moehs DP, Bhatti MI. 1999a. Precision and accuracy of lifetimes of metastable levels using the Ringdon trap technique. Int J Mass Spectrom, 192:149-155.
    • (1999) Int J Mass Spectrom , vol.192 , pp. 149-155
    • Church, D.A.1    Moehs, D.P.2    Bhatti, M.I.3
  • 35
    • 84990671383 scopus 로고
    • Mass shifts due to ion/ion interactions in a quadrupole ion-trap mass spectrometer
    • Cleven CD, Cox KA, Cooks RG, Bier ME. 1994. Mass shifts due to ion/ion interactions in a quadrupole ion-trap mass spectrometer. Rapid Commun Mass Spectrom 8:451-454.
    • (1994) Rapid Commun Mass Spectrom , vol.8 , pp. 451-454
    • Cleven, C.D.1    Cox, K.A.2    Cooks, R.G.3    Bier, M.E.4
  • 36
    • 0030568148 scopus 로고    scopus 로고
    • Radial distributions and ejection times of molecular ions in an ion trap mass spectrometer: A laser tomography study of effects of ion density and molecular type
    • Cleven CD, Cooks RG, Garrett AW, Nogar NS, Hemberger PH. 1996a. Radial distributions and ejection times of molecular ions in an ion trap mass spectrometer: A laser tomography study of effects of ion density and molecular type. J Phys Chem 100:40-46.
    • (1996) J Phys Chem , vol.100 , pp. 40-46
    • Cleven, C.D.1    Cooks, R.G.2    Garrett, A.W.3    Nogar, N.S.4    Hemberger, P.H.5
  • 37
    • 0001537098 scopus 로고    scopus 로고
    • Selective photodissociation of trapped ions after ion cloud manipulation with an impulsive quadrupolar electric field
    • Cleven CD, Nappi M, Cooks RG, Garrett AW, Nogar NS, Hemberger PH. 1996b. Selective photodissociation of trapped ions after ion cloud manipulation with an impulsive quadrupolar electric field. J Phys Chem 100:5205-5209.
    • (1996) J Phys Chem , vol.100 , pp. 5205-5209
    • Cleven, C.D.1    Nappi, M.2    Cooks, R.G.3    Garrett, A.W.4    Nogar, N.S.5    Hemberger, P.H.6
  • 38
    • 17644408113 scopus 로고    scopus 로고
    • Versatile new ion source for the analysis of materials in open air under ambient conditions
    • Cody RB, Laramee JA, Durst HD. 2005. Versatile new ion source for the analysis of materials in open air under ambient conditions. Anal Chem 77:2297-2302.
    • (2005) Anal Chem , vol.77 , pp. 2297-2302
    • Cody, R.B.1    Laramee, J.A.2    Durst, H.D.3
  • 39
    • 0001268221 scopus 로고
    • Fourier transform ion cyclotron resonance spectroscopy
    • Comisarow MB, Marshall AG. 1974. Fourier transform ion cyclotron resonance spectroscopy. Chem Phys Lett 25:282-283.
    • (1974) Chem Phys Lett , vol.25 , pp. 282-283
    • Comisarow, M.B.1    Marshall, A.G.2
  • 42
    • 57249104167 scopus 로고    scopus 로고
    • Cooks RG, Cleven CD, Horn LA, Nappi M, Weil C, Soni MH, Julian RKJ. 1995. Non-destructive detection of ions in a quadrupole ion trap using a d.c. pulse to force coherent ion motion: A simulation study. Int J Mass Spectrom, Ion, Processes 146/147:147-163. Coon JJ, Syka JEP, Schwartz JC, Shabanowitz J, Hunt DF. 2004. Anion dependence in the partitioning between proton and electron transfer in ion/ion reactions. Int J Mass Spectrom 236:33-42.
    • Cooks RG, Cleven CD, Horn LA, Nappi M, Weil C, Soni MH, Julian RKJ. 1995. Non-destructive detection of ions in a quadrupole ion trap using a d.c. pulse to force coherent ion motion: A simulation study. Int J Mass Spectrom, Ion, Processes 146/147:147-163. Coon JJ, Syka JEP, Schwartz JC, Shabanowitz J, Hunt DF. 2004. Anion dependence in the partitioning between proton and electron transfer in ion/ion reactions. Int J Mass Spectrom 236:33-42.
  • 44
    • 0001917118 scopus 로고
    • Mass shifts and local space charge effects observed in the quadrupole ion trap at higher resolution
    • Cox KA, Cleven CD, Cooks RG. 1995. Mass shifts and local space charge effects observed in the quadrupole ion trap at higher resolution. Int J Mass Spectrom Ion Processes 144:47-65.
    • (1995) Int J Mass Spectrom Ion Processes , vol.144 , pp. 47-65
    • Cox, K.A.1    Cleven, C.D.2    Cooks, R.G.3
  • 46
    • 35748945154 scopus 로고    scopus 로고
    • Identification of N.N ε-dimethyl-lysine in the murine dioxin receptor using MALDI-TOF/TOF-and ESI-LTQ-Orbitrap-FT-MS
    • Dave KA, Hamilton BR, Wallis TP, Fumess SGB, Whitelaw ML, Gorman JJ. 2007. Identification of N.N ε-dimethyl-lysine in the murine dioxin receptor using MALDI-TOF/TOF-and ESI-LTQ-Orbitrap-FT-MS. Int J Mass Spectrom 268:168-180.
    • (2007) Int J Mass Spectrom , vol.268 , pp. 168-180
    • Dave, K.A.1    Hamilton, B.R.2    Wallis, T.P.3    Fumess, S.G.B.4    Whitelaw, M.L.5    Gorman, J.J.6
  • 48
    • 0030022989 scopus 로고    scopus 로고
    • Tandem mass spectrometry: A primer
    • de Hoffmann E. 1996. Tandem mass spectrometry: A primer. J Mass Spectrom 31:129-137.
    • (1996) J Mass Spectrom , vol.31 , pp. 129-137
    • de Hoffmann, E.1
  • 50
    • 33748754288 scopus 로고    scopus 로고
    • Identification of 491 proteins in the tear fluid proteome reveals a large number of proteases and protease inhibitors
    • de Souza GA, Godoy LMF, Mann M. 2006. Identification of 491 proteins in the tear fluid proteome reveals a large number of proteases and protease inhibitors. Genome Biol 7:R72.
    • (2006) Genome Biol , vol.7
    • de Souza, G.A.1    Godoy, L.M.F.2    Mann, M.3
  • 51
    • 45549100467 scopus 로고    scopus 로고
    • A hybrid method for peptide identification using integer linear optimization, local database search, and quadrupole time-of-flight or orbitrap tandem mass spectrometry
    • DiMaggio PA, Floudas CA, Lu B, Yates JR. 2008. A hybrid method for peptide identification using integer linear optimization, local database search, and quadrupole time-of-flight or orbitrap tandem mass spectrometry. J Proteome Res 7:1584-1593.
    • (2008) J Proteome Res , vol.7 , pp. 1584-1593
    • DiMaggio, P.A.1    Floudas, C.A.2    Lu, B.3    Yates, J.R.4
  • 53
    • 26844503278 scopus 로고
    • Molecular beams of macroions
    • Dole M, Mack LL, Hines RL. 1968. Molecular beams of macroions. J Chem Phys 49:2240-2249.
    • (1968) J Chem Phys , vol.49 , pp. 2240-2249
    • Dole, M.1    Mack, L.L.2    Hines, R.L.3
  • 55
    • 1542365366 scopus 로고    scopus 로고
    • BIRD (Blackbody Infrared Radiative Dissociation): Evolution, principles, and applications
    • Dunbar RC. 2004. BIRD (Blackbody Infrared Radiative Dissociation): Evolution, principles, and applications. Mass Spectrom Rev 23:127158.
    • (2004) Mass Spectrom Rev , vol.23 , pp. 127158
    • Dunbar, R.C.1
  • 56
    • 0033473716 scopus 로고    scopus 로고
    • Isotope beating effects in the analysis of polymer distributions by Fourier transform mass spectrometry
    • Easterling ML, Amster IJ, van Rooij GJ, Heeren RMA. 1999. Isotope beating effects in the analysis of polymer distributions by Fourier transform mass spectrometry. J Am Soc Mass Spectrom 10:1074-1082.
    • (1999) J Am Soc Mass Spectrom , vol.10 , pp. 1074-1082
    • Easterling, M.L.1    Amster, I.J.2    van Rooij, G.J.3    Heeren, R.M.A.4
  • 57
    • 33645513074 scopus 로고    scopus 로고
    • Collision-induced dissociation pathways of yeast sphingolipids and their molecular profiling in total, lipid extracts: A study by quadrupole TOF and linear ion trap-orbitrap mass spectrometry
    • Ejsing CS, Moehring T, Bahr U, Duchoslav E, Karas M, Simons K, Shevchenko A. 2006. Collision-induced dissociation pathways of yeast sphingolipids and their molecular profiling in total, lipid extracts: A study by quadrupole TOF and linear ion trap-orbitrap mass spectrometry. J Mass Spectrom 41:372-389.
    • (2006) J Mass Spectrom , vol.41 , pp. 372-389
    • Ejsing, C.S.1    Moehring, T.2    Bahr, U.3    Duchoslav, E.4    Karas, M.5    Simons, K.6    Shevchenko, A.7
  • 58
    • 0024438708 scopus 로고
    • Electrospray ionization for mass spectrometry of large biomolecules
    • Fenn JB, Mann M, Meng CK, Wong SF, Whitehouse CM. 1989. Electrospray ionization for mass spectrometry of large biomolecules. Science 246:64-71.
    • (1989) Science , vol.246 , pp. 64-71
    • Fenn, J.B.1    Mann, M.2    Meng, C.K.3    Wong, S.F.4    Whitehouse, C.M.5
  • 59
    • 0035866680 scopus 로고    scopus 로고
    • High-mass accuracy of product ions produced by SORI-CID using a dual electrospray ionization source coupled with FTICR mass spectrometry
    • Flora JW, Hannis JC, Muddiman DC. 2001, High-mass accuracy of product ions produced by SORI-CID using a dual electrospray ionization source coupled with FTICR mass spectrometry. Anal Chem 73:1247-1251.
    • (2001) Anal Chem , vol.73 , pp. 1247-1251
    • Flora, J.W.1    Hannis, J.C.2    Muddiman, D.C.3
  • 60
    • 38749146267 scopus 로고    scopus 로고
    • Qualitative and quantitative characterization of the amyloid β peptide (Aß) population in biological matrices using an immunoprecipitation-LC/MS assay
    • Ford MJ, Cantone JL, Poison C, Toyn JH, Meredith JE, Drexler DM. 2008. Qualitative and quantitative characterization of the amyloid β peptide (Aß) population in biological matrices using an immunoprecipitation-LC/MS assay. J Neurosci Methods 168:465-474.
    • (2008) J Neurosci Methods , vol.168 , pp. 465-474
    • Ford, M.J.1    Cantone, J.L.2    Poison, C.3    Toyn, J.H.4    Meredith, J.E.5    Drexler, D.M.6
  • 61
    • 33845417140 scopus 로고    scopus 로고
    • Mild protease treatment as a small-scale biochemical method for mitochondria purification and proteomic mapping of cytoplasm-exposed mitochondrial proteins
    • Forner F, Arriaga EA, Mann M. 2006. Mild protease treatment as a small-scale biochemical method for mitochondria purification and proteomic mapping of cytoplasm-exposed mitochondrial proteins. J Proteome Res 5:3277-3287.
    • (2006) J Proteome Res , vol.5 , pp. 3277-3287
    • Forner, F.1    Arriaga, E.A.2    Mann, M.3
  • 63
    • 0019033927 scopus 로고
    • Radio-frequency mass selective excitation and resonant ejection of ions in a three-dimensional quadrupole ion trap
    • Fulford JE, Hoa D-N, Hughes RJ, March RE, Bonner RF, Wong GJ. 1980. Radio-frequency mass selective excitation and resonant ejection of ions in a three-dimensional quadrupole ion trap. J Vac Sci Technol 17:829-835.
    • (1980) J Vac Sci Technol , vol.17 , pp. 829-835
    • Fulford, J.E.1    Hoa, D.-N.2    Hughes, R.J.3    March, R.E.4    Bonner, R.F.5    Wong, G.J.6
  • 66
    • 0001984250 scopus 로고
    • Neutralized ion beam spectroscopy
    • Gellene GI, Porter RF. 1983. Neutralized ion beam spectroscopy. Acc Chem Res 16:200-207.
    • (1983) Acc Chem Res , vol.16 , pp. 200-207
    • Gellene, G.I.1    Porter, R.F.2
  • 67
    • 0013310813 scopus 로고    scopus 로고
    • Ion motion in a Fourier transform ion cyclotron resonance wire ion guide cell
    • Gillig KJ, Bluhm BK, Russell DH. 1996. Ion motion in a Fourier transform ion cyclotron resonance wire ion guide cell. Int J Mass Spectrom 157/158:129-147.
    • (1996) Int J Mass Spectrom , vol.157-158 , pp. 129-147
    • Gillig, K.J.1    Bluhm, B.K.2    Russell, D.H.3
  • 68
    • 0029402802 scopus 로고
    • Ion remeasurement in the radio frequency quadrupole ion trap
    • Goeringer DE, Crutcher RI, McLuckey SA. 1995. Ion remeasurement in the radio frequency quadrupole ion trap. Anal Chem. 67:4164-4169.
    • (1995) Anal Chem , vol.67 , pp. 4164-4169
    • Goeringer, D.E.1    Crutcher, R.I.2    McLuckey, S.A.3
  • 69
    • 42649132889 scopus 로고    scopus 로고
    • Stable isotope labeling by amino acids in cell culture (SILAC) and proteome quantitation of mouse embryonic stem cells to a depth of 5,111 proteins
    • Graumann J, Hubner NC, Kim JB, Ko K, Moser M, Kumar C, Cox J, Scḧler H, Mann M. 2008. Stable isotope labeling by amino acids in cell culture (SILAC) and proteome quantitation of mouse embryonic stem cells to a depth of 5,111 proteins. Mol Cell Proteomics 7:672-683.
    • (2008) Mol Cell Proteomics , vol.7 , pp. 672-683
    • Graumann, J.1    Hubner, N.C.2    Kim, J.B.3    Ko, K.4    Moser, M.5    Kumar, C.6    Cox, J.7    Scḧler, H.8    Mann, M.9
  • 70
    • 0027600624 scopus 로고
    • Stored waveform inverse Fourier transform axial excitation/ejection for quadrupole ion trap mass spectrometry
    • Guan S, Marshall AG. 1993. Stored waveform inverse Fourier transform axial excitation/ejection for quadrupole ion trap mass spectrometry. Anal Chem 65:1288-1294.
    • (1993) Anal Chem , vol.65 , pp. 1288-1294
    • Guan, S.1    Marshall, A.G.2
  • 71
    • 33744901953 scopus 로고    scopus 로고
    • Phosphopeptide anion characterization via sequential charge inversion and electron-transfer dissociation
    • Gunawardena HP, Emory JF, McLuckey SA. 2006. Phosphopeptide anion characterization via sequential charge inversion and electron-transfer dissociation. Anal Chem 78:3788-3793.
    • (2006) Anal Chem , vol.78 , pp. 3788-3793
    • Gunawardena, H.P.1    Emory, J.F.2    McLuckey, S.A.3
  • 72
    • 0036199431 scopus 로고    scopus 로고
    • A new linear ion trap mass spectrometer
    • Hager JW. 2002. A new linear ion trap mass spectrometer. Rapid Commun Mass Spectrom 16:512-526.
    • (2002) Rapid Commun Mass Spectrom , vol.16 , pp. 512-526
    • Hager, J.W.1
  • 73
    • 44449162195 scopus 로고    scopus 로고
    • Hanke S, Besir H, Oesterhelt D, Mann M. 2008. Absolute SILAC for accurate quantitation of proteins in complex mixtures down to the attomole level. J Proteome Res 7:1.118-1130.
    • Hanke S, Besir H, Oesterhelt D, Mann M. 2008. Absolute SILAC for accurate quantitation of proteins in complex mixtures down to the attomole level. J Proteome Res 7:1.118-1130.
  • 74
    • 0034475555 scopus 로고    scopus 로고
    • A dual electrospray ionization source combined widi hexapole accumulation to achieve high mass accuracy of biopolymers in Fourier transform ion cyclotron resonance mass spectrometry
    • Hannis JC, Muddiman DC. 2000. A dual electrospray ionization source combined widi hexapole accumulation to achieve high mass accuracy of biopolymers in Fourier transform ion cyclotron resonance mass spectrometry. J Am Soc Mass Spectrom 11:876-883.
    • (2000) J Am Soc Mass Spectrom , vol.11 , pp. 876-883
    • Hannis, J.C.1    Muddiman, D.C.2
  • 75
    • 0037398266 scopus 로고    scopus 로고
    • Interfacing the orbitrap mass analyzer to an electrospray ion source
    • Hardman M, Makarov AA. 2003. Interfacing the orbitrap mass analyzer to an electrospray ion source. Anal Chem 75:1699-1705.
    • (2003) Anal Chem , vol.75 , pp. 1699-1705
    • Hardman, M.1    Makarov, A.A.2
  • 76
    • 1242284991 scopus 로고    scopus 로고
    • Theoretical and experimental prospects for protein identification based solely on accurate mass measurement
    • He F, Emmett MR, Hakansson K, Hendrickson CL, Marshall AG. 2004. Theoretical and experimental prospects for protein identification based solely on accurate mass measurement. J Proteome Res 3:61-67.
    • (2004) J Proteome Res , vol.3 , pp. 61-67
    • He, F.1    Emmett, M.R.2    Hakansson, K.3    Hendrickson, C.L.4    Marshall, A.G.5
  • 77
    • 0000571944 scopus 로고
    • Laser photodissociation probe for ion tomography studies in a quadrupole ion-trap mass spectrometer
    • Hemberger PH, Nogar NS, Williams JD, Cooks RG, Syka JEP. 1992. Laser photodissociation probe for ion tomography studies in a quadrupole ion-trap mass spectrometer. Chem. Phys Lett 191:405-410.
    • (1992) Chem. Phys Lett , vol.191 , pp. 405-410
    • Hemberger, P.H.1    Nogar, N.S.2    Williams, J.D.3    Cooks, R.G.4    Syka, J.E.P.5
  • 78
    • 17444375706 scopus 로고    scopus 로고
    • Complementary structural information from a tryptic N-linked glycopeptide via electron transfer ion/ion reactions and collision-induced dissociation
    • Hogan JM, Pitteri SJ, Chrisman PA, McLuckey SA. 2005. Complementary structural information from a tryptic N-linked glycopeptide via electron transfer ion/ion reactions and collision-induced dissociation. J Proteome Res 4:628-632.
    • (2005) J Proteome Res , vol.4 , pp. 628-632
    • Hogan, J.M.1    Pitteri, S.J.2    Chrisman, P.A.3    McLuckey, S.A.4
  • 79
    • 34547727671 scopus 로고    scopus 로고
    • High-speed data reduction, feature detection and MS/MS spectrum quality assessment of shotgun proteomics data sets using high-resolution mass spectrometry
    • Hoopmann MR, Finney GL, MacCoss MJ. 2007. High-speed data reduction, feature detection and MS/MS spectrum quality assessment of shotgun proteomics data sets using high-resolution mass spectrometry. Anal Chem 79:5620-5632.
    • (2007) Anal Chem , vol.79 , pp. 5620-5632
    • Hoopmann, M.R.1    Finney, G.L.2    MacCoss, M.J.3
  • 80
    • 33947086174 scopus 로고
    • New picogram detection system based on a mass spectrometer with an external ionization source at atmospheric pressure
    • Horning EC, Horning MG, Carroll DI, Dzidic I, Stillwell RN. 1973. New picogram detection system based on a mass spectrometer with an external ionization source at atmospheric pressure. Anal Chem 45:936-943.
    • (1973) Anal Chem , vol.45 , pp. 936-943
    • Horning, E.C.1    Horning, M.G.2    Carroll, D.I.3    Dzidic, I.4    Stillwell, R.N.5
  • 81
    • 0016125497 scopus 로고
    • Atmospheric-pressure ionization mass-spectrometry - Solvent-mediated ionization of samples introduced in solution and in a liquid chromatograph effluent stream
    • Horning EC, Carroll DI, Dzidic I, Haegele KD, Homing MG, Stillwell RN. 1974a. Atmospheric-pressure ionization mass-spectrometry - Solvent-mediated ionization of samples introduced in solution and in a liquid chromatograph effluent stream. J Chromatogr Sci 12:725-729.
    • (1974) J Chromatogr Sci , vol.12 , pp. 725-729
    • Horning, E.C.1    Carroll, D.I.2    Dzidic, I.3    Haegele, K.D.4    Homing, M.G.5    Stillwell, R.N.6
  • 82
    • 0002168795 scopus 로고
    • Liquid chromatograph-mass spectrometer-computer analytical systems. A continuous-flow system based on atmospheric pressure ionization mass spectrometry
    • Horning EC, Carroll DI, Dzidic I, Haegele KD, Horning MG, Stillwell RN. 1974b. Liquid chromatograph-mass spectrometer-computer analytical systems. A continuous-flow system based on atmospheric pressure ionization mass spectrometry. J Chromatogr 99:13-21.
    • (1974) J Chromatogr , vol.99 , pp. 13-21
    • Horning, E.C.1    Carroll, D.I.2    Dzidic, I.3    Haegele, K.D.4    Horning, M.G.5    Stillwell, R.N.6
  • 84
    • 33644930009 scopus 로고    scopus 로고
    • Resonant ac dipolar excitation for ion motion control in the orbitrap mass analyzer
    • Hu Q, Makarov AA, Cooks RG, Noll RJ. 2006a. Resonant ac dipolar excitation for ion motion control in the orbitrap mass analyzer. J Phys Chem A 110:2682-2689.
    • (2006) J Phys Chem A , vol.110 , pp. 2682-2689
    • Hu, Q.1    Makarov, A.A.2    Cooks, R.G.3    Noll, R.J.4
  • 85
    • 33751074675 scopus 로고    scopus 로고
    • Desorption electrospray ionization using an orbitrap mass spectrometer: Exact mass measurements on drugs and peptides
    • Hu Q, Talaty N, Noll RJ, Cooks RG. 2006b. Desorption electrospray ionization using an orbitrap mass spectrometer: Exact mass measurements on drugs and peptides. Rapid Commun Mass Spectrom 20:3403 - 3408.
    • (2006) Rapid Commun Mass Spectrom , vol.20 , pp. 3403-3408
    • Hu, Q.1    Talaty, N.2    Noll, R.J.3    Cooks, R.G.4
  • 86
    • 34248562183 scopus 로고    scopus 로고
    • Phase-enhanced selective ion ejection in an orbitrap mass spectrometer
    • Hu Q, Cooks RG, Noll RJ. 2007. Phase-enhanced selective ion ejection in an orbitrap mass spectrometer. J Am Soc Mass Spectrom 18:980-983.
    • (2007) J Am Soc Mass Spectrom , vol.18 , pp. 980-983
    • Hu, Q.1    Cooks, R.G.2    Noll, R.J.3
  • 87
    • 33750691680 scopus 로고    scopus 로고
    • Electron-transfer reagent anion formation via electrospray ionization and collisioninduced dissociation
    • Huang TY, Emory JF, O'Hair RA, McLuckey SA, 2006. Electron-transfer reagent anion formation via electrospray ionization and collisioninduced dissociation. Anal. Chem 78:7387-7391.
    • (2006) Anal. Chem , vol.78 , pp. 7387-7391
    • Huang, T.Y.1    Emory, J.F.2    O'Hair, R.A.3    McLuckey, S.A.4
  • 88
    • 0002749254 scopus 로고    scopus 로고
    • 1.92.1. The effect of a uniform, magnetic field on the motion of electrons between coaxial, cylinders
    • Hull AW. 1.92.1. The effect of a uniform, magnetic field on the motion of electrons between coaxial, cylinders. Phys Rev 18:31-57.
    • Phys Rev , vol.18 , pp. 31-57
    • Hull, A.W.1
  • 90
    • 36349025164 scopus 로고    scopus 로고
    • New insights in the formation of deoxynucleoside adducts with the heterocyclic aromatic amines PhIP and IQ by means of ion trap MSn and accurate mass measurement of fragment ions
    • Jamin EL, Arquier D, Canlet C, Rathahao E, Tulliez J, Debrauwer L. 2007. New insights in the formation of deoxynucleoside adducts with the heterocyclic aromatic amines PhIP and IQ by means of ion trap MSn and accurate mass measurement of fragment ions. J Am Soc Mass Spectrom 18:2107-2118.
    • (2007) J Am Soc Mass Spectrom , vol.18 , pp. 2107-2118
    • Jamin, E.L.1    Arquier, D.2    Canlet, C.3    Rathahao, E.4    Tulliez, J.5    Debrauwer, L.6
  • 91
    • 0000192319 scopus 로고
    • Broad-band excitation in the quadrupole ion trap mass spectrometer using shaped pulses created with the inverse Fourier transform
    • Julian RK, Cooks RG. 1993. Broad-band excitation in the quadrupole ion trap mass spectrometer using shaped pulses created with the inverse Fourier transform. Anal Chem 65:1827-1833.
    • (1993) Anal Chem , vol.65 , pp. 1827-1833
    • Julian, R.K.1    Cooks, R.G.2
  • 92
    • 0001912777 scopus 로고
    • Multiparticle simulation of ion motion in the ion trap mass spectrometer: Resonant and direct current pulse excitation
    • Julian RK, Nappi M, Weil C, Cooks RG. 1995. Multiparticle simulation of ion motion in the ion trap mass spectrometer: Resonant and direct current pulse excitation. J Am Soc Mass Spectrom 6:57-70.
    • (1995) J Am Soc Mass Spectrom , vol.6 , pp. 57-70
    • Julian, R.K.1    Nappi, M.2    Weil, C.3    Cooks, R.G.4
  • 97
    • 0000849532 scopus 로고
    • A method for the neutralization of electron space charge by positive ionization at very low gas pressures
    • Kingdon KH, 1923. A method for the neutralization of electron space charge by positive ionization at very low gas pressures. Phys Rev 21: 408-418.
    • (1923) Phys Rev , vol.21 , pp. 408-418
    • Kingdon, K.H.1
  • 98
    • 0039038005 scopus 로고
    • Storage of ions from laser-produced plasmas
    • Knight RD. 1981, Storage of ions from laser-produced plasmas. Appl Phys Lett 38:221-222.
    • (1981) Appl Phys Lett , vol.38 , pp. 221-222
    • Knight, R.D.1
  • 99
    • 18344384838 scopus 로고
    • A study of the ion-optical properties of a sector-shaped electrostatic field of the difference type
    • Korsunskii MI, Bazsakutsa VA. 1958. A study of the ion-optical properties of a sector-shaped electrostatic field of the difference type. Sov Phys Tech Phys 3:1396-1409.
    • (1958) Sov Phys Tech Phys , vol.3 , pp. 1396-1409
    • Korsunskii, M.I.1    Bazsakutsa, V.A.2
  • 100
    • 38849173797 scopus 로고    scopus 로고
    • Analysis of nitrosamines in wastewater: Exploring the trace level quantification capabilities of a hybrid linear ion trap/orbitrap mass spectrometer
    • Krauss M, Hollender J. 2008. Analysis of nitrosamines in wastewater: Exploring the trace level quantification capabilities of a hybrid linear ion trap/orbitrap mass spectrometer. Anal Chem 80:834-842.
    • (2008) Anal Chem , vol.80 , pp. 834-842
    • Krauss, M.1    Hollender, J.2
  • 101
    • 0000598484 scopus 로고
    • Surface-induced dissociation of molecular ions in a quadrupole ion trap mass spectrometer
    • Lammert SA, Cooks RG. 1991, Surface-induced dissociation of molecular ions in a quadrupole ion trap mass spectrometer. J Am Soc Mass Spectrom 2:487-491.
    • (1991) J Am Soc Mass Spectrom , vol.2 , pp. 487-491
    • Lammert, S.A.1    Cooks, R.G.2
  • 102
    • 84990658544 scopus 로고
    • Pulsed axial activation in the ion trap - A new method for performing tandem mass spectroscopy (MS/MS)
    • Lammert SA, Cooks RG. 1992. Pulsed axial activation in the ion trap - A new method for performing tandem mass spectroscopy (MS/MS). Rapid Commun Mass Spectrom. 6:528-530.
    • (1992) Rapid Commun Mass Spectrom , vol.6 , pp. 528-530
    • Lammert, S.A.1    Cooks, R.G.2
  • 103
    • 0001779356 scopus 로고
    • Determination of ion frequencies in a quadrupole ion trap by using a fast DC pulse as pump and a laser probe
    • Lammert SA, Cleven CD, Cooks RG. 1994. Determination of ion frequencies in a quadrupole ion trap by using a fast DC pulse as pump and a laser probe. J Am Soc Mass Spectrom 5:29-36.
    • (1994) J Am Soc Mass Spectrom , vol.5 , pp. 29-36
    • Lammert, S.A.1    Cleven, C.D.2    Cooks, R.G.3
  • 104
    • 57249114150 scopus 로고
    • Sykes JB, Bell JS
    • Landau LD, Lifshitz EM. Translated from Russian by, Oxford; NY: Pergamon Press
    • Landau LD, Lifshitz EM. Translated from Russian by Sykes JB, Bell JS. 1976. Mechanics. Oxford; NY: Pergamon Press.
    • (1976) Mechanics
  • 106
    • 0020139126 scopus 로고
    • Motion of ions in the Kingdon trap
    • Lewis RR. 1982. Motion of ions in the Kingdon trap. J Appl Phys 53:3975-3980.
    • (1982) J Appl Phys , vol.53 , pp. 3975-3980
    • Lewis, R.R.1
  • 107
    • 37649024925 scopus 로고    scopus 로고
    • Complete profiling and characterization of in vitro nefazodone metabolites using two different tandem mass spectrometric platforms
    • Li AC, Shou WZ, Mai TT, Jiang X-Y. 2007a. Complete profiling and characterization of in vitro nefazodone metabolites using two different tandem mass spectrometric platforms. Rapid Commun Mass Spectrom 21:4001-4008.
    • (2007) Rapid Commun Mass Spectrom , vol.21 , pp. 4001-4008
    • Li, A.C.1    Shou, W.Z.2    Mai, T.T.3    Jiang, X.-Y.4
  • 109
    • 33646586062 scopus 로고    scopus 로고
    • Alternately pulsed nanoelectrospray ionization/atmospheric pressure chemical ionization for ion/ion reactions in an electrodynamic ion trap
    • Liang X, Xia Y, McLuckey SA. 2006. Alternately pulsed nanoelectrospray ionization/atmospheric pressure chemical ionization for ion/ion reactions in an electrodynamic ion trap. Anal Chem. 78:3208-3212.
    • (2006) Anal Chem , vol.78 , pp. 3208-3212
    • Liang, X.1    Xia, Y.2    McLuckey, S.A.3
  • 110
    • 34250707998 scopus 로고    scopus 로고
    • Metabolite identification by data-dependent accurate mass spectrometric analysis at resolving power of 60,000 in external, calibration mode using an LTQ/Orbitrap
    • Lim H-K, Chen J, Sensenhauser C, Cook K, Subrahmanyam V. 2007. Metabolite identification by data-dependent accurate mass spectrometric analysis at resolving power of 60,000 in external, calibration mode using an LTQ/Orbitrap. Rapid Commun Mass Spectrom 21:1821-1832.
    • (2007) Rapid Commun Mass Spectrom , vol.21 , pp. 1821-1832
    • Lim, H.-K.1    Chen, J.2    Sensenhauser, C.3    Cook, K.4    Subrahmanyam, V.5
  • 111
    • 42649118458 scopus 로고    scopus 로고
    • A generic method to detect electrophilic intermediates using isotopic pattern triggered data-dependent high-resolution accurate mass spectrometry
    • Lim H-K, Chen J, Cook K, Sensenhauser C, Silva J, Evans DC. 2008. A generic method to detect electrophilic intermediates using isotopic pattern triggered data-dependent high-resolution accurate mass spectrometry. Rapid Commun Mass Spectrom 22:1295-1311.
    • (2008) Rapid Commun Mass Spectrom , vol.22 , pp. 1295-1311
    • Lim, H.-K.1    Chen, J.2    Cook, K.3    Sensenhauser, C.4    Silva, J.5    Evans, D.C.6
  • 112
    • 0027997748 scopus 로고
    • Infrared multiphoton dissociation of larger multiply charged ions for biomolecule sequencing
    • Little DP, Speir JP, Senko MW, O'Connor PB, McLafferty FW. 1994. Infrared multiphoton dissociation of larger multiply charged ions for biomolecule sequencing. Anal. Chem. 66:2809-2815.
    • (1994) Anal. Chem , vol.66 , pp. 2809-2815
    • Little, D.P.1    Speir, J.P.2    Senko, M.W.3    O'Connor, P.B.4    McLafferty, F.W.5
  • 113
    • 35748939071 scopus 로고    scopus 로고
    • Nanoelectrospray peptide mapping revisited: Composite survey spectra allow high dynamic range protein characterization without LCMS on an orbitrap mass spectrometer
    • Lu A, Waanders LF, Almeida R, Li G, Allen M, Cox J, Olsen JV, Bonaldi T, Mann M. 2007. Nanoelectrospray peptide mapping revisited: Composite survey spectra allow high dynamic range protein characterization without LCMS on an orbitrap mass spectrometer. Int J Mass Spectrom 268:158-167.
    • (2007) Int J Mass Spectrom , vol.268 , pp. 158-167
    • Lu, A.1    Waanders, L.F.2    Almeida, R.3    Li, G.4    Allen, M.5    Cox, J.6    Olsen, J.V.7    Bonaldi, T.8    Mann, M.9
  • 114
    • 41449095461 scopus 로고    scopus 로고
    • Improving protein identification sensitivity by combining MS and MS/MS information for shotgun proteomics using LTQ-Orbitrap high mass accuracy data
    • Lu B, Motoyama A, Ruse C, Venable JD, Yates JR. 2008. Improving protein identification sensitivity by combining MS and MS/MS information for shotgun proteomics using LTQ-Orbitrap high mass accuracy data. Anal Chem 80:2018-2025.
    • (2008) Anal Chem , vol.80 , pp. 2018-2025
    • Lu, B.1    Motoyama, A.2    Ruse, C.3    Venable, J.D.4    Yates, J.R.5
  • 116
    • 42949111593 scopus 로고    scopus 로고
    • Direct introduction of biological samples into a LTQ-Orbitrap hybrid mass spectrometer as a tool for fast metabolome analysis
    • Madalinski G, Godat E, Alves S, Lesage D, Genin E, Levi P, Labarre J, Tabet J-C, Ezan E, Junot C. 2008. Direct introduction of biological samples into a LTQ-Orbitrap hybrid mass spectrometer as a tool for fast metabolome analysis. Anal Chem 80:3291-3303.
    • (2008) Anal Chem , vol.80 , pp. 3291-3303
    • Madalinski, G.1    Godat, E.2    Alves, S.3    Lesage, D.4    Genin, E.5    Levi, P.6    Labarre, J.7    Tabet, J.-C.8    Ezan, E.9    Junot, C.10
  • 117
    • 36049055027 scopus 로고
    • Exchange-collision technique for RF spectroscopy of stored ions
    • Major FG, Dehmelt HG. 1968. Exchange-collision technique for RF spectroscopy of stored ions. Phys Rev 170:91 -107.
    • (1968) Phys Rev , vol.170 , pp. 91-107
    • Major, F.G.1    Dehmelt, H.G.2
  • 118
    • 38649131141 scopus 로고    scopus 로고
    • Mass spectrometer
    • US Patent 5,886,346
    • Makarov A. 1999. Mass spectrometer. US Patent 5,886,346.
    • (1999)
    • Makarov, A.1
  • 119
    • 0041408938 scopus 로고    scopus 로고
    • Electrostatic axially harmonic orbital trapping: A. high-performance technique of mass analysis
    • Makarov A, 2000. Electrostatic axially harmonic orbital trapping: A. high-performance technique of mass analysis. Anal. Chem. 72:1156-1162.
    • (2000) Anal. Chem , vol.72 , pp. 1156-1162
    • Makarov, A.1
  • 120
    • 57249114152 scopus 로고    scopus 로고
    • Mass spectrometry method and apparatus
    • US Patent 6,872,938
    • Makarov A, Hardman M, Schwartz J, Senko M. 2002. Mass spectrometry method and apparatus. US Patent 6,872,938.
    • (2002)
    • Makarov, A.1    Hardman, M.2    Schwartz, J.3    Senko, M.4
  • 122
    • 33745264884 scopus 로고    scopus 로고
    • Dynamic range of mass accuracy in LTQ orbitrap hybrid mass spectrometer
    • Makarov AA, Denisov E, Lange O, Horning S. 2006b. Dynamic range of mass accuracy in LTQ orbitrap hybrid mass spectrometer. J Am Soc Mass Spectrom. 17:977-982.
    • (2006) J Am Soc Mass Spectrom , vol.17 , pp. 977-982
    • Makarov, A.A.1    Denisov, E.2    Lange, O.3    Horning, S.4
  • 124
  • 125
    • 0031623267 scopus 로고    scopus 로고
    • 1.998. Fourier transform ion cyclotron resonance mass spectrometry: A primer
    • Marshall AG, Hendrickson CL, Jackson GS. 1.998. Fourier transform ion cyclotron resonance mass spectrometry: A primer. Mass Spec Rev 17:1-35.
    • Mass Spec Rev , vol.17 , pp. 1-35
    • Marshall, A.G.1    Hendrickson, C.L.2    Jackson, G.S.3
  • 127
    • 34249022000 scopus 로고    scopus 로고
    • Implementation of electron-transfer dissociation on a hybrid linear ion trap-orbitrap mass spectrometer
    • McAlister GC, Phanstiel D, Good DM, Berggren WT, Coon JJ. 2007. Implementation of electron-transfer dissociation on a hybrid linear ion trap-orbitrap mass spectrometer. Anal Chem 79:3525-3534.
    • (2007) Anal Chem , vol.79 , pp. 3525-3534
    • McAlister, G.C.1    Phanstiel, D.2    Good, D.M.3    Berggren, W.T.4    Coon, J.J.5
  • 128
    • 28544448597 scopus 로고    scopus 로고
    • Analysis of solids, liquids, and biological tissues using solids probe introduction at atmospheric pressure on commercial LC/MS instruments
    • McEwen CN, McKay RG, Larsen BS. 2005. Analysis of solids, liquids, and biological tissues using solids probe introduction at atmospheric pressure on commercial LC/MS instruments. Anal Chem 77:7826-7831.
    • (2005) Anal Chem , vol.77 , pp. 7826-7831
    • McEwen, C.N.1    McKay, R.G.2    Larsen, B.S.3
  • 129
    • 34250715913 scopus 로고    scopus 로고
    • Analysis of the inhibition of the ergosterol pathway in fungi using the atmospheric solids analysis probe (ASAP) method
    • McEwen CN, Gutteridge S. 2007. Analysis of the inhibition of the ergosterol pathway in fungi using the atmospheric solids analysis probe (ASAP) method. J Am Soc Mass Spectrom 18:1274-1278.
    • (2007) J Am Soc Mass Spectrom , vol.18 , pp. 1274-1278
    • McEwen, C.N.1    Gutteridge, S.2
  • 130
    • 33747352146 scopus 로고
    • A charged particle oscillator
    • McIlraith AH. 1966. A charged particle oscillator. Nature 212:1422-1424.
    • (1966) Nature , vol.212 , pp. 1422-1424
    • McIlraith, A.H.1
  • 131
    • 0002172992 scopus 로고
    • Tandem, mass spectrometry (MS/MS): A promising new analytical technique for specific component determination in complex mixtures
    • McLafferty FW. 1980. Tandem, mass spectrometry (MS/MS): A promising new analytical technique for specific component determination in complex mixtures. Ace Chem Res 13:33-39.
    • (1980) Ace Chem Res , vol.13 , pp. 33-39
    • McLafferty, F.W.1
  • 132
    • 0019882891 scopus 로고
    • Tandem, mass spectrometry
    • McLafferty FW. 1981, Tandem, mass spectrometry. Science 214:280-287.
    • (1981) Science , vol.214 , pp. 280-287
    • McLafferty, F.W.1
  • 134
    • 0000936323 scopus 로고
    • Neutralization-reionization mass spectrometry
    • McLafferty FW. 1992. Neutralization-reionization mass spectrometry. Int J Mass Spectrom Ion Processes 118/119:221-235.
    • (1992) Int J Mass Spectrom Ion Processes , vol.118-119 , pp. 221-235
    • McLafferty, F.W.1
  • 135
    • 0023385467 scopus 로고
    • Collision-activated dissociation of negative-ions in an ion trap mass-spectrometer
    • McLuckey SA, Glish GL, Kelley PE. 1987. Collision-activated dissociation of negative-ions in an ion trap mass-spectrometer. Anal Chem 59:1670-1674.
    • (1987) Anal Chem , vol.59 , pp. 1670-1674
    • McLuckey, S.A.1    Glish, G.L.2    Kelley, P.E.3
  • 136
    • 0002076981 scopus 로고
    • Selective ion isolation/rejection over a broad mass range in the quadrupole ion trap
    • McLuckey SA, Goeringer DE, Glish GL. 1991, Selective ion isolation/rejection over a broad mass range in the quadrupole ion trap. J Am Soc Mass Spectrom 2:11-21.
    • (1991) J Am Soc Mass Spectrom , vol.2 , pp. 11-21
    • McLuckey, S.A.1    Goeringer, D.E.2    Glish, G.L.3
  • 137
    • 0035246248 scopus 로고    scopus 로고
    • Mass analysis at the advent of the 21st century
    • McLuckey SA, Wells JM. 2001. Mass analysis at the advent of the 21st century. Chem Rev 101:571-606.
    • (2001) Chem Rev , vol.101 , pp. 571-606
    • McLuckey, S.A.1    Wells, J.M.2
  • 138
    • 0000816094 scopus 로고    scopus 로고
    • Magnetic dipole transition rates from measured lifetimes of levels of Be-like and Be-like argon ions
    • Moehs DP, Church DA. 1998. Magnetic dipole transition rates from measured lifetimes of levels of Be-like and Be-like argon ions. Phys Rev A: At Mol. Opt Phys 58:1111-1114.
    • (1998) Phys Rev A: At Mol. Opt Phys , vol.58 , pp. 1111-1114
    • Moehs, D.P.1    Church, D.A.2
  • 139
    • 0001043034 scopus 로고    scopus 로고
    • Kingdon trap apparatus and technique for precise measurement of the lifetimes of metastable levels of ions
    • Moehs DP, Church DA, Phaneuf RA. 1998. Kingdon trap apparatus and technique for precise measurement of the lifetimes of metastable levels of ions. Rev Sci Instrum 69:1991-1995.
    • (1998) Rev Sci Instrum , vol.69 , pp. 1991-1995
    • Moehs, D.P.1    Church, D.A.2    Phaneuf, R.A.3
  • 140
    • 0001100965 scopus 로고    scopus 로고
    • Moehs DP, Church DA. 1999. Measured lifetimes of metastable levels of Mn X, Mn XI, Mn XII and Mn XIII ions. Phys Rev A: At Mol Opt Phys 59:1.884-1889.
    • Moehs DP, Church DA. 1999. Measured lifetimes of metastable levels of Mn X, Mn XI, Mn XII and Mn XIII ions. Phys Rev A: At Mol Opt Phys 59:1.884-1889.
  • 141
    • 0034229108 scopus 로고    scopus 로고
    • Excited-configuration metastable level lifetimes of Cl-like Mn IX and Fe X
    • Moehs DP, Church DA, Bhatti MI, Perger WF. 2000. Excited-configuration metastable level lifetimes of Cl-like Mn IX and Fe X, Phys Rev Lett 85:38-41.
    • (2000) Phys Rev Lett , vol.85 , pp. 38-41
    • Moehs, D.P.1    Church, D.A.2    Bhatti, M.I.3    Perger, W.F.4
  • 142
    • 0035279740 scopus 로고    scopus 로고
    • Measurements and calculations of metastable level lifetimes in Fe X, Fe XI, Fe XII, Fe XIII and Fe IV
    • Moehs DP, Bhatti MI, Church DA. 2001, Measurements and calculations of metastable level lifetimes in Fe X, Fe XI, Fe XII, Fe XIII and Fe IV. Phys Rev A: At Mol Opt Phys 63:032515.
    • (2001) Phys Rev A: At Mol Opt Phys , vol.63 , pp. 032515
    • Moehs, D.P.1    Bhatti, M.I.2    Church, D.A.3
  • 143
    • 0029717657 scopus 로고    scopus 로고
    • High sensitivity collisionaily-activated decomposition tandem mass spectrometry on a novel quadrupole/orthogonal-acceleration time-of-flight mass spectrometer
    • Morris HR, Paxton T, Dell A, Langhorne J, Matthias B, Bordoli RS, Hoyes J, Bateman RH. 1996. High sensitivity collisionaily-activated decomposition tandem mass spectrometry on a novel quadrupole/orthogonal-acceleration time-of-flight mass spectrometer. Rapid Commun Mass Spectrom. 10:889-896.
    • (1996) Rapid Commun Mass Spectrom , vol.10 , pp. 889-896
    • Morris, H.R.1    Paxton, T.2    Dell, A.3    Langhorne, J.4    Matthias, B.5    Bordoli, R.S.6    Hoyes, J.7    Bateman, R.H.8
  • 145
    • 0001982081 scopus 로고    scopus 로고
    • Characteristics of a broadband Fourier transform ion trap mass spectrometer
    • Nappi M, Frankevich V, Soni M, Cooks RG. 1998. Characteristics of a broadband Fourier transform ion trap mass spectrometer. Int J Mass Spectrom 177:91-104.
    • (1998) Int J Mass Spectrom , vol.177 , pp. 91-104
    • Nappi, M.1    Frankevich, V.2    Soni, M.3    Cooks, R.G.4
  • 146
    • 0242418236 scopus 로고    scopus 로고
    • Dual electrospray ionization source for confident generation of accurate mass tags using liquid chromatography Fourier transform ion cyclotron resonance mass spectrometry
    • Nepomuceno AI, Muddiman DC, Bergen HR, Craighead JR, Burke MJ, Caskey PE, Allan JA. 2003. Dual electrospray ionization source for confident generation of accurate mass tags using liquid chromatography Fourier transform ion cyclotron resonance mass spectrometry. Anal Chem 75:3411-3418.
    • (2003) Anal Chem , vol.75 , pp. 3411-3418
    • Nepomuceno, A.I.1    Muddiman, D.C.2    Bergen, H.R.3    Craighead, J.R.4    Burke, M.J.5    Caskey, P.E.6    Allan, J.A.7
  • 147
    • 33846895151 scopus 로고    scopus 로고
    • Screening and confirmation criteria for hormone residue analysis using liquid chromatography accurate mass time-of-flight, Fourier transform ion cyclotron resonance and orbitrap mass spectrometry techniques
    • Nielen MWF, van Engelen MC, Zuiderent R, Ramaker R. 2007. Screening and confirmation criteria for hormone residue analysis using liquid chromatography accurate mass time-of-flight, Fourier transform ion cyclotron resonance and orbitrap mass spectrometry techniques. Anal Chim Acta 586:122-129.
    • (2007) Anal Chim Acta , vol.586 , pp. 122-129
    • Nielen, M.W.F.1    van Engelen, M.C.2    Zuiderent, R.3    Ramaker, R.4
  • 148
    • 23244443897 scopus 로고    scopus 로고
    • Characterization of synthetic nucleic acids by electrospray ionization quadrupole time-of-flight mass spectrometry
    • Oberacher H, Niederstatter H, Parson W. 2005. Characterization of synthetic nucleic acids by electrospray ionization quadrupole time-of-flight mass spectrometry. J Mass Spectrom 40:932-945.
    • (2005) J Mass Spectrom , vol.40 , pp. 932-945
    • Oberacher, H.1    Niederstatter, H.2    Parson, W.3
  • 149
    • 0042616115 scopus 로고    scopus 로고
    • Oksman P. 1995. A. Fourier transform time-of-flight mass spectrometer. A, SIMION calculation approach. Int J Mass Spectrom 141:67-76.
    • Oksman P. 1995. A. Fourier transform time-of-flight mass spectrometer. A, SIMION calculation approach. Int J Mass Spectrom 141:67-76.
  • 152
    • 41549117597 scopus 로고    scopus 로고
    • A quantitative analysis software tool for mass spectrometry-based proteomics
    • Park SK, Venable JD, Xu T, Yates JR. 2008. A quantitative analysis software tool for mass spectrometry-based proteomics. Nat Methods 5:319-322.
    • (2008) Nat Methods , vol.5 , pp. 319-322
    • Park, S.K.1    Venable, J.D.2    Xu, T.3    Yates, J.R.4
  • 153
    • 0000751135 scopus 로고
    • Cluster experiments in radio frequency Paul traps: Collisional relaxation and dissociation
    • Parks JH. Pollack. S, Hill. W. 1994. Cluster experiments in radio frequency Paul traps: Collisional relaxation and dissociation. J Chem Phys 101: 6666-6685.
    • (1994) J Chem Phys , vol.101 , pp. 6666-6685
    • Parks, J.H.1    Pollack, S.2    Hill, W.3
  • 154
    • 84885653762 scopus 로고
    • Ein neues massenspektrometer ohne magnetfeld.
    • Paul W, Steinwedel HS, 1953. Ein neues massenspektrometer ohne magnetfeld. Z Naturf A 8:448-450.
    • (1953) Z Naturf A , vol.8 , pp. 448-450
    • Paul, W.1    Steinwedel, H.S.2
  • 155
    • 33344464424 scopus 로고    scopus 로고
    • Application of a linear ion trap/orbitrap mass spectrometer in metabolite characterization studies: Examination of the human liver microsomal metabolism of the non-trieyclie anti-depressant nefazodone using data-dependent accurate mass measurements
    • Peterman SM, Duczak N Jr, Kalgutkar AS, Lame ME, Soglia JR. 2006. Application of a linear ion trap/orbitrap mass spectrometer in metabolite characterization studies: Examination of the human liver microsomal metabolism of the non-trieyclie anti-depressant nefazodone using data-dependent accurate mass measurements. J Am Soc Mass Spectrom 17:363-375.
    • (2006) J Am Soc Mass Spectrom , vol.17 , pp. 363-375
    • Peterman, S.M.1    Duczak Jr, N.2    Kalgutkar, A.S.3    Lame, M.E.4    Soglia, J.R.5
  • 156
    • 0029988666 scopus 로고    scopus 로고
    • Tandem, mass spectrometry of large biomolecule ions by blackbody infrared radiative dissociation
    • Price WD, Schnier PD, Williams ER. 1996. Tandem, mass spectrometry of large biomolecule ions by blackbody infrared radiative dissociation. Anal Chem 68:859-866.
    • (1996) Anal Chem , vol.68 , pp. 859-866
    • Price, W.D.1    Schnier, P.D.2    Williams, E.R.3
  • 159
    • 0000029151 scopus 로고
    • Radiative decay rates of metastable Ar III and Cu II ions
    • Prior MH. 1984. Radiative decay rates of metastable Ar III and Cu II ions. Phys Rev A: At Mol Opt Phys 30:3051-3056.
    • (1984) Phys Rev A: At Mol Opt Phys , vol.30 , pp. 3051-3056
    • Prior, M.H.1
  • 160
    • 0036315870 scopus 로고    scopus 로고
    • Top down' protein characterization via tandem, mass spectrometry
    • Reid GE, McLuckey SA. 2002. 'Top down' protein characterization via tandem, mass spectrometry. J Mass Spectrom 37:663-675.
    • (2002) J Mass Spectrom , vol.37 , pp. 663-675
    • Reid, G.E.1    McLuckey, S.A.2
  • 161
    • 0006137735 scopus 로고
    • Experimental studies of charged dust particles
    • Robertson S. 1995. Experimental studies of charged dust particles. Phys Plasmas 2:2200-2206.
    • (1995) Phys Plasmas , vol.2 , pp. 2200-2206
    • Robertson, S.1
  • 162
    • 24344444935 scopus 로고
    • Collective behavior of non-neutral plasma in a Ringdon trap
    • Robertson S, Alexander D. 1995. Collective behavior of non-neutral plasma in a Ringdon trap. Phys Plasmas 2:3-5.
    • (1995) Phys Plasmas , vol.2 , pp. 3-5
    • Robertson, S.1    Alexander, D.2
  • 164
    • 39749201504 scopus 로고    scopus 로고
    • An integrated method for metabolite detection and identification using a linear ion trap/orbitrap mass spectrometer and multiple data processing techniques: Application to indinavir metabolite detection
    • Ruan Q, Peterman S, Szewc MA, Ma L, Cui D, Humphreys WG, Zhu M. 2008. An integrated method for metabolite detection and identification using a linear ion trap/orbitrap mass spectrometer and multiple data processing techniques: Application to indinavir metabolite detection. J Mass Spectrom 43:251-261.
    • (2008) J Mass Spectrom , vol.43 , pp. 251-261
    • Ruan, Q.1    Peterman, S.2    Szewc, M.A.3    Ma, L.4    Cui, D.5    Humphreys, W.G.6    Zhu, M.7
  • 165
    • 33751334373 scopus 로고    scopus 로고
    • Generation and detection of multiply-charged peptides and proteins by matrix-assisted laser desorption electrospray ionization (MALDESI) Fourier transform ion cyclotron resonance mass spectrometry
    • Sampson JS, Hawkridge AM, Muddiman DC. 2006. Generation and detection of multiply-charged peptides and proteins by matrix-assisted laser desorption electrospray ionization (MALDESI) Fourier transform ion cyclotron resonance mass spectrometry. J Am Soc Mass Spectrom 17:1712-1716.
    • (2006) J Am Soc Mass Spectrom , vol.17 , pp. 1712-1716
    • Sampson, J.S.1    Hawkridge, A.M.2    Muddiman, D.C.3
  • 166
    • 39449111536 scopus 로고    scopus 로고
    • Genome-specific gas-phase fractionation strategy for improved shotgun proteomic profiling of proteotypic peptides
    • Scherl A, Shaffer SA, Taylor GK, Kulasekara HD, Miller SI, Goodlett DR. 2008. Genome-specific gas-phase fractionation strategy for improved shotgun proteomic profiling of proteotypic peptides. Anal. Chem 80:1182-1191.
    • (2008) Anal. Chem , vol.80 , pp. 1182-1191
    • Scherl, A.1    Shaffer, S.A.2    Taylor, G.K.3    Kulasekara, H.D.4    Miller, S.I.5    Goodlett, D.R.6
  • 167
    • 0029768104 scopus 로고    scopus 로고
    • Blackbody infrared radiative dissociation of bradykinin and its analogues: Energetics, dynamics, and evidence for salt-bridge structures in the gas phase
    • Schnier PD, Price WD, Jockusch RA, Williams ER. 1996. Blackbody infrared radiative dissociation of bradykinin and its analogues: Energetics, dynamics, and evidence for salt-bridge structures in the gas phase. J Am Chem Soc 118:7178-7189.
    • (1996) J Am Chem Soc , vol.118 , pp. 7178-7189
    • Schnier, P.D.1    Price, W.D.2    Jockusch, R.A.3    Williams, E.R.4
  • 168
    • 0025482937 scopus 로고
    • Systematic delineation of scan modes in multidimensional mass spectrometry
    • Schwartz JC, Wade AP, Enke CG, Cooks RG. 1990. Systematic delineation of scan modes in multidimensional mass spectrometry. Anal Chem. 62:1809-1818.
    • (1990) Anal Chem , vol.62 , pp. 1809-1818
    • Schwartz, J.C.1    Wade, A.P.2    Enke, C.G.3    Cooks, R.G.4
  • 169
    • 4444366208 scopus 로고
    • Method and apparatus of increasing dynamic range and sensitivity of a mass spectrometer
    • US Patent 5,572,022
    • Schwartz JC, Zhou XG, Bier ME. 1995. Method and apparatus of increasing dynamic range and sensitivity of a mass spectrometer. US Patent 5,572,022.
    • (1995)
    • Schwartz, J.C.1    Zhou, X.G.2    Bier, M.E.3
  • 171
    • 4243343110 scopus 로고
    • Fourier transform mass spectrometry without ion cyclotron resonance: Direct observation of the trapping frequency of trapped ions
    • Schweikhard L, Blundschling M, Jertz R, Kluge H-J. 1989. Fourier transform mass spectrometry without ion cyclotron resonance: Direct observation of the trapping frequency of trapped ions. Int J Mass Spectrom Ion Processes 89:R7-R12.
    • (1989) Int J Mass Spectrom Ion Processes , vol.89
    • Schweikhard, L.1    Blundschling, M.2    Jertz, R.3    Kluge, H.-J.4
  • 173
    • 33750319346 scopus 로고    scopus 로고
    • Orbitrap mass analyzer - Overview and applications in proteomics
    • Scigelova M, Makarov A. 2006. Orbitrap mass analyzer - Overview and applications in proteomics. Proteomics 6:16-21.
    • (2006) Proteomics , vol.6 , pp. 16-21
    • Scigelova, M.1    Makarov, A.2
  • 175
    • 0030481735 scopus 로고    scopus 로고
    • A high-performance modular data system for Fourier transform ion cyclotron resonance mass spectrometry
    • Senko MW, Canterbury JD, Guan S, Marshall AG. 1996. A high-performance modular data system for Fourier transform ion cyclotron resonance mass spectrometry. Rapid Commun Mass Spectrom 10:1839-1844.
    • (1996) Rapid Commun Mass Spectrom , vol.10 , pp. 1839-1844
    • Senko, M.W.1    Canterbury, J.D.2    Guan, S.3    Marshall, A.G.4
  • 176
    • 0031239787 scopus 로고    scopus 로고
    • External accumulation of ions for enhanced electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    • Senko MW, Hendrickson CL, Emmett MR, Shi SD-H, Marshall AG. 1997. External accumulation of ions for enhanced electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. J Am Soc Mass Spectrom 8:970-976.
    • (1997) J Am Soc Mass Spectrom , vol.8 , pp. 970-976
    • Senko, M.W.1    Hendrickson, C.L.2    Emmett, M.R.3    Shi, S.D.-H.4    Marshall, A.G.5
  • 178
    • 85159251640 scopus 로고    scopus 로고
    • Shevchenko A, Chernushevich I, Ens W, Standing KG, Thomson B, Wilm M, Mann M. 1997. Rapid 'de Novo' peptide sequencing by a combination of nanoelectrospray, isotopic labeling and a quadrupole/time-of-flight mass spectrometer. Rapid Commun Mass Spectrom 11:101.5-1024.
    • Shevchenko A, Chernushevich I, Ens W, Standing KG, Thomson B, Wilm M, Mann M. 1997. Rapid 'de Novo' peptide sequencing by a combination of nanoelectrospray, isotopic labeling and a quadrupole/time-of-flight mass spectrometer. Rapid Commun Mass Spectrom 11:101.5-1024.
  • 180
    • 29144501611 scopus 로고    scopus 로고
    • Electrospray-assisted laser desorption/ionization mass spectrometry for direct ambient analysis of solids
    • Shiea J, Huang MZ, Hsu HJ, Lee CY, Yuan CH, Beech I, Sunner J. 2005. Electrospray-assisted laser desorption/ionization mass spectrometry for direct ambient analysis of solids. Rapid Commun Mass Spectrom 19:3701-3704.
    • (2005) Rapid Commun Mass Spectrom , vol.19 , pp. 3701-3704
    • Shiea, J.1    Huang, M.Z.2    Hsu, H.J.3    Lee, C.Y.4    Yuan, C.H.5    Beech, I.6    Sunner, J.7
  • 185
    • 0028438486 scopus 로고
    • Detection of high-mass biomolecules in Fourier transform ion cyclotron resonance mass spectrometry: Theoretical and experimental investigations
    • Solouki T, Gillig KJ, Russell DH. 1994. Detection of high-mass biomolecules in Fourier transform ion cyclotron resonance mass spectrometry: Theoretical and experimental investigations. Anal Chem. 66:1583-1587.
    • (1994) Anal Chem , vol.66 , pp. 1583-1587
    • Solouki, T.1    Gillig, K.J.2    Russell, D.H.3
  • 186
    • 0028485837 scopus 로고
    • Selective injection and isolation of ions in quadrupole ion trap mass spectrometry using notched waveforms created using the inverse Fourier transform
    • Soni M, Cooks RG. 1994. Selective injection and isolation of ions in quadrupole ion trap mass spectrometry using notched waveforms created using the inverse Fourier transform. Anal. Chem 66:2488-2496.
    • (1994) Anal. Chem , vol.66 , pp. 2488-2496
    • Soni, M.1    Cooks, R.G.2
  • 189
    • 0035298820 scopus 로고    scopus 로고
    • Detection of tyrosine phosphorylated peptides by precursor ion scanning quadrupole TOF mass spectrometry in positive ion mode
    • Steen H, Küster B, Fernandez M, Pandey A, Mann M. 2001, Detection of tyrosine phosphorylated peptides by precursor ion scanning quadrupole TOF mass spectrometry in positive ion mode. Anal Chem 73:1440-1448.
    • (2001) Anal Chem , vol.73 , pp. 1440-1448
    • Steen, H.1    Küster, B.2    Fernandez, M.3    Pandey, A.4    Mann, M.5
  • 192
    • 0037543845 scopus 로고
    • Fourier transform quadrupole mass spectrometer and method
    • US Patent 4,755,670
    • Syka JEP, Fies WJ. 1988. Fourier transform quadrupole mass spectrometer and method. US Patent 4,755,670.
    • (1988)
    • Syka, J.E.P.1    Fies, W.J.2
  • 195
    • 0037133237 scopus 로고    scopus 로고
    • Top-down mass spectrometry of a 29-kDa protein for characterization of any posttranslational modification to within one residue
    • Sze SK, Ge Y, Oh H, McLafferty FW. 2002. Top-down mass spectrometry of a 29-kDa protein for characterization of any posttranslational modification to within one residue. Proc Natl Acad Sci. USA 99:1774-1779.
    • (2002) Proc Natl Acad Sci. USA , vol.99 , pp. 1774-1779
    • Sze, S.K.1    Ge, Y.2    Oh, H.3    McLafferty, F.W.4
  • 196
    • 5644249240 scopus 로고    scopus 로고
    • Mass spectrometry sampling under ambient conditions with desorption electrospray ionization
    • Takats Z, Wiseman JM, Gologan B, Cooks RG. 2004. Mass spectrometry sampling under ambient conditions with desorption electrospray ionization. Science 306:471-473.
    • (2004) Science , vol.306 , pp. 471-473
    • Takats, Z.1    Wiseman, J.M.2    Gologan, B.3    Cooks, R.G.4
  • 197
    • 18044393045 scopus 로고    scopus 로고
    • Direct, trace level detection of explosives on ambient surfaces by desorption electrospray ionization mass spectrometry
    • Takats Z, Cotte-Rodriguez I, Talaty N, Chen HW, Cooks RG. 2005. Direct, trace level detection of explosives on ambient surfaces by desorption electrospray ionization mass spectrometry. Chem Commun (15): 1950-1952.
    • (2005) Chem Commun , vol.15 , pp. 1950-1952
    • Takats, Z.1    Cotte-Rodriguez, I.2    Talaty, N.3    Chen, H.W.4    Cooks, R.G.5
  • 198
    • 27944477716 scopus 로고    scopus 로고
    • Mass spectrometry of stanozolol and its analogues using electrospray ionization and collision-induced dissociation with quadrupole-linear ion trap and linear ion trap-orbitrap mass analyzers
    • Thevis M, Makarov AA, Horning S, Sehänzer W. 2005. Mass spectrometry of stanozolol and its analogues using electrospray ionization and collision-induced dissociation with quadrupole-linear ion trap and linear ion trap-orbitrap mass analyzers. Rapid Commun Mass Spectrom. 19:3369-3378.
    • (2005) Rapid Commun Mass Spectrom , vol.19 , pp. 3369-3378
    • Thevis, M.1    Makarov, A.A.2    Horning, S.3    Sehänzer, W.4
  • 199
    • 33845330271 scopus 로고    scopus 로고
    • Determination of Synacthen in human plasma using immunoaffinity purification and liquid chromatography/tandem mass spectrometry
    • Thevis M, Bredehöft M, Geyer H, Kamber M, Delahaut P, Sehänzer W 2006a. Determination of Synacthen in human plasma using immunoaffinity purification and liquid chromatography/tandem mass spectrometry. Rapid Commun Mass Spectrom 20:3551-3556.
    • (2006) Rapid Commun Mass Spectrom , vol.20 , pp. 3551-3556
    • Thevis, M.1    Bredehöft, M.2    Geyer, H.3    Kamber, M.4    Delahaut, P.5    Sehänzer, W.6
  • 200
    • 33644643993 scopus 로고    scopus 로고
    • Screening for metabolically stable aryl-propionamide-derived selective androgen receptor modulators for doping control purposes
    • Thevis M, Kamber M, Sehänzer W 2006b. Screening for metabolically stable aryl-propionamide-derived selective androgen receptor modulators for doping control purposes. Rapid Commun Mass Spectrom 20:870-876.
    • (2006) Rapid Commun Mass Spectrom , vol.20 , pp. 870-876
    • Thevis, M.1    Kamber, M.2    Sehänzer, W.3
  • 201
    • 33645516229 scopus 로고    scopus 로고
    • Mass spectrometric characterization of efaproxiral (RSR13) and its implementation into doping controls using liquid chromatography-atmospheric pressure ionization-tandem mass spectrometry
    • Thevis M, Krug O, Sehänzer W. 2006c. Mass spectrometric characterization of efaproxiral (RSR13) and its implementation into doping controls using liquid chromatography-atmospheric pressure ionization-tandem mass spectrometry. J Mass Spectrom 41:332-338.
    • (2006) J Mass Spectrom , vol.41 , pp. 332-338
    • Thevis, M.1    Krug, O.2    Sehänzer, W.3
  • 202
    • 33745590849 scopus 로고    scopus 로고
    • Determination of N-desmethyl- and N-bisdesmethyl metabolites of Sibutramine in doping control analysis using liquid chromatography-tandem mass spectrometry
    • Thevis M, Sigmund G, Schiffer A-K, Sehänzer W. 2006d. Determination of N-desmethyl- and N-bisdesmethyl metabolites of Sibutramine in doping control analysis using liquid chromatography-tandem mass spectrometry. Eur J Mass Spectrom 12:129-136.
    • (2006) Eur J Mass Spectrom , vol.12 , pp. 129-136
    • Thevis, M.1    Sigmund, G.2    Schiffer, A.-K.3    Sehänzer, W.4
  • 203
    • 33751077291 scopus 로고    scopus 로고
    • Determination of merapeutics with growth-hormone secretagogue activity in human urine for doping control purposes
    • Thevis M, Wilkens F, Geyer H, Sehänzer W. 2006e. Determination of merapeutics with growth-hormone secretagogue activity in human urine for doping control purposes. Rapid Commun Mass Spectrom 20:3393-3402.
    • (2006) Rapid Commun Mass Spectrom , vol.20 , pp. 3393-3402
    • Thevis, M.1    Wilkens, F.2    Geyer, H.3    Sehänzer, W.4
  • 204
  • 206
    • 42449084465 scopus 로고    scopus 로고
    • Determination of benzimidazole- and bicyclic hydantoin-derived selective androgen receptor antagonists and agonists in human urine using LC-MS/MS
    • Thevis M, Kohler M, Thomas A, Maurer J, Schlörer N, Kamber M, Sehänzer W. 2008a. Determination of benzimidazole- and bicyclic hydantoin-derived selective androgen receptor antagonists and agonists in human urine using LC-MS/MS. Anal Bioanal Chem 391:251-261.
    • (2008) Anal Bioanal Chem , vol.391 , pp. 251-261
    • Thevis, M.1    Kohler, M.2    Thomas, A.3    Maurer, J.4    Schlörer, N.5    Kamber, M.6    Sehänzer, W.7
  • 207
    • 37249011308 scopus 로고    scopus 로고
    • Mass spectrometric determination of insulins and their degradation products in sports drug testing
    • Thevis M, Thomas A, Sehänzer W. 2008b. Mass spectrometric determination of insulins and their degradation products in sports drug testing. Mass Spectrom. Rev 27:35-50.
    • (2008) Mass Spectrom. Rev , vol.27 , pp. 35-50
    • Thevis, M.1    Thomas, A.2    Sehänzer, W.3
  • 208
    • 38649098761 scopus 로고    scopus 로고
    • Characterization of global yeast quantitative proteome data generated from the wild-type and glucose repression Saccharomyces cerevisiae strains: The comparison of two quantitative methods
    • Usarte R, Wohlschlegel J, Venable JD, Park SK, Nielsen J, Olsson L, Yates JR. 2008. Characterization of global yeast quantitative proteome data generated from the wild-type and glucose repression Saccharomyces cerevisiae strains: The comparison of two quantitative methods. J Proteome Res 7:266-275.
    • (2008) J Proteome Res , vol.7 , pp. 266-275
    • Usarte, R.1    Wohlschlegel, J.2    Venable, J.D.3    Park, S.K.4    Nielsen, J.5    Olsson, L.6    Yates, J.R.7
  • 209
    • 0029841145 scopus 로고    scopus 로고
    • Attomole protein characterization by capillary electrophoresis-mass spectrometry
    • Valaskovic GA, Kelleher NL, McLafferty FW. 1996. Attomole protein characterization by capillary electrophoresis-mass spectrometry. Science 273:1199-1202.
    • (1996) Science , vol.273 , pp. 1199-1202
    • Valaskovic, G.A.1    Kelleher, N.L.2    McLafferty, F.W.3
  • 211
    • 34247365096 scopus 로고    scopus 로고
    • Relative quantification of stable isotope labeled peptides using a linear ion trap-orbitrap hybrid mass spectrometer
    • Venable JD, Wohlschlegel J, McClatchy DB, Park SK, Yates JR. 2007. Relative quantification of stable isotope labeled peptides using a linear ion trap-orbitrap hybrid mass spectrometer. Anal Chem. 79:3056-3064.
    • (2007) Anal Chem , vol.79 , pp. 3056-3064
    • Venable, J.D.1    Wohlschlegel, J.2    McClatchy, D.B.3    Park, S.K.4    Yates, J.R.5
  • 212
    • 35448967750 scopus 로고    scopus 로고
    • Top-down quantitation and characterization of SILAC-labeled proteins
    • Waanders LF, Hanke S, Mann M. 2007. Top-down quantitation and characterization of SILAC-labeled proteins. J Am. Soc Mass Spectrom. 18:2058-2064.
    • (2007) J Am. Soc Mass Spectrom , vol.18 , pp. 2058-2064
    • Waanders, L.F.1    Hanke, S.2    Mann, M.3
  • 213
    • 0034614304 scopus 로고    scopus 로고
    • Axial ion motion within the quadrupole ion trap elucidated by dc pulse tomography
    • Weil C, Wells JM, Wollnik H, Cooks RG. 2000. Axial ion motion within the quadrupole ion trap elucidated by dc pulse tomography. Int J Mass Spectrom 194:225-234.
    • (2000) Int J Mass Spectrom , vol.194 , pp. 225-234
    • Weil, C.1    Wells, J.M.2    Wollnik, H.3    Cooks, R.G.4
  • 214
    • 28544441463 scopus 로고    scopus 로고
    • Direct analysis of pharmaceutical drug formulations using ion mobility spectrometry/quadrupole-time-of-flight mass spectrometry combined with desorption electrospray ionization
    • Weston DJ, Bateman R, Wilson ID, Wood TR, Greaser CS. 2005. Direct analysis of pharmaceutical drug formulations using ion mobility spectrometry/quadrupole-time-of-flight mass spectrometry combined with desorption electrospray ionization. Anal Chem. 77:7572-7580.
    • (2005) Anal Chem , vol.77 , pp. 7572-7580
    • Weston, D.J.1    Bateman, R.2    Wilson, I.D.3    Wood, T.R.4    Greaser, C.S.5
  • 215
    • 0022029557 scopus 로고
    • Electrospray interface for liquid chromatographs and mass spectrometers
    • Whitehouse CM, Dreyer RN, Yamashita M, Fenn JB. 1985. Electrospray interface for liquid chromatographs and mass spectrometers. Anal Chem 57:675-679.
    • (1985) Anal Chem , vol.57 , pp. 675-679
    • Whitehouse, C.M.1    Dreyer, R.N.2    Yamashita, M.3    Fenn, J.B.4
  • 216
    • 33845926390 scopus 로고    scopus 로고
    • Sub parts-per-million mass measurement accuracy of intact proteins and product ions achieved using a dual electrospray ionization quadrupole Fourier transform ion cyclotron resonance mass spectrometer
    • Williams DK, Hawkridge AM, Muddiman DC. 2007a. Sub parts-per-million mass measurement accuracy of intact proteins and product ions achieved using a dual electrospray ionization quadrupole Fourier transform ion cyclotron resonance mass spectrometer. J Am. Soc Mass Spectrom 18:1-7.
    • (2007) J Am. Soc Mass Spectrom , vol.18 , pp. 1-7
    • Williams, D.K.1    Hawkridge, A.M.2    Muddiman, D.C.3
  • 217
    • 35448946118 scopus 로고    scopus 로고
    • Dual electrospray ion source for electron-transfer dissociation on a hybrid linear ion trap-orbitrap mass spectrometer
    • Williams DK, McAlister GC, Good DM, Coon JJ, Muddiman DC. 2007b. Dual electrospray ion source for electron-transfer dissociation on a hybrid linear ion trap-orbitrap mass spectrometer. Anal Chem. 79:7916-7919.
    • (2007) Anal Chem , vol.79 , pp. 7916-7919
    • Williams, D.K.1    McAlister, G.C.2    Good, D.M.3    Coon, J.J.4    Muddiman, D.C.5
  • 218
    • 84990651369 scopus 로고
    • Reduction of space-charging in the quadrupole ion trap by sequential injection and simultaneous storage of positively and negatively charged ions
    • Williams JD, Cooks RG. 1993. Reduction of space-charging in the quadrupole ion trap by sequential injection and simultaneous storage of positively and negatively charged ions. Rapid Commun Mass Spectrom. 7:380-382.
    • (1993) Rapid Commun Mass Spectrom , vol.7 , pp. 380-382
    • Williams, J.D.1    Cooks, R.G.2
  • 219
    • 0000040394 scopus 로고
    • Determination of positions, velocities and kinetic energies of resonantly excited ions in the quadrupole ion trap mass spectrometer by laser photodissociation
    • Williams JD, Cooks RG, Syka JEP, Hemberger PH, Nogar NS. 1993. Determination of positions, velocities and kinetic energies of resonantly excited ions in the quadrupole ion trap mass spectrometer by laser photodissociation. J Am Soc Mass Spectrom. 4:792-797.
    • (1993) J Am Soc Mass Spectrom , vol.4 , pp. 792-797
    • Williams, J.D.1    Cooks, R.G.2    Syka, J.E.P.3    Hemberger, P.H.4    Nogar, N.S.5
  • 220
    • 1642346048 scopus 로고    scopus 로고
    • Using accurate mass electrospray ionization-time-of-flight mass spectrometry with in-source collision-induced dissociation to sequence peptide mixtures
    • Williams JD, Flanagan M, Lopez L, Fischer S, Miller LAD. 2003. Using accurate mass electrospray ionization-time-of-flight mass spectrometry with in-source collision-induced dissociation to sequence peptide mixtures. J Chromatogr A 1020:11-26.
    • (2003) J Chromatogr A , vol.1020 , pp. 11-26
    • Williams, J.D.1    Flanagan, M.2    Lopez, L.3    Fischer, S.4    Miller, L.A.D.5
  • 221
    • 29144470654 scopus 로고    scopus 로고
    • Rapid accurate mass desorption electrospray ionization tandem mass spectrometry of pharmaceutical samples
    • Williams JP, Scrivens JH. 2005. Rapid accurate mass desorption electrospray ionization tandem mass spectrometry of pharmaceutical samples. Rapid Commun Mass Spectrom 19:3643-3650.
    • (2005) Rapid Commun Mass Spectrom , vol.19 , pp. 3643-3650
    • Williams, J.P.1    Scrivens, J.H.2
  • 223
    • 33846488609 scopus 로고    scopus 로고
    • Mass spectrometric mapping of linker histone H1 variants reveals multiple acetylations, methylations, and phosphorylation as well as differences between cell culture and tissue
    • Wisniewski JR, Zougman A, Kruger S, Mann M. 2007. Mass spectrometric mapping of linker histone H1 variants reveals multiple acetylations, methylations, and phosphorylation as well as differences between cell culture and tissue. Mol. Cell Proteomics 6:72-87.
    • (2007) Mol. Cell Proteomics , vol.6 , pp. 72-87
    • Wisniewski, J.R.1    Zougman, A.2    Kruger, S.3    Mann, M.4
  • 225
    • 27144458820 scopus 로고    scopus 로고
    • Pulsed dual electrospray ionization for ion/ion reactions
    • Xia Y, Liang X, McLuckey SA. 2005. Pulsed dual electrospray ionization for ion/ion reactions. J Am. Soc Mass Spectrom. 16:1750-1756.
    • (2005) J Am. Soc Mass Spectrom , vol.16 , pp. 1750-1756
    • Xia, Y.1    Liang, X.2    McLuckey, S.A.3
  • 227
    • 33144464594 scopus 로고    scopus 로고
    • Ion trap versus low-energy beam-type collision-induced dissociation of protonated ubiquitin ions
    • Xia Y, Liang X, McLuckey SA. 2006b. Ion trap versus low-energy beam-type collision-induced dissociation of protonated ubiquitin ions. Anal Chem 78:1218-1227.
    • (2006) Anal Chem , vol.78 , pp. 1218-1227
    • Xia, Y.1    Liang, X.2    McLuckey, S.A.3
  • 228
    • 33845471401 scopus 로고
    • Negative ion production with the electrospray ion source
    • Yamashita M, Fenn JB. 1984a. Negative ion production with the electrospray ion source. J Phys Chem 88:4671-4675.
    • (1984) J Phys Chem , vol.88 , pp. 4671-4675
    • Yamashita, M.1    Fenn, J.B.2
  • 229
    • 33748168091 scopus 로고
    • Electrospray ion source. Another variation on the free-jet theme
    • Yamashita M, Fenn JB. 1984b. Electrospray ion source. Another variation on the free-jet theme. J Phys Chem. 88:4451-4459.
    • (1984) J Phys Chem , vol.88 , pp. 4451-4459
    • Yamashita, M.1    Fenn, J.B.2
  • 231
    • 0001589187 scopus 로고
    • Lifetime measurements on long-lived levels of confined highly charged ions
    • Yang L, Church DA. 1993. Lifetime measurements on long-lived levels of confined highly charged ions. Phys Rev Lett 70:3860-3863.
    • (1993) Phys Rev Lett , vol.70 , pp. 3860-3863
    • Yang, L.1    Church, D.A.2
  • 234
    • 30744476222 scopus 로고    scopus 로고
    • Performance of a linear ion trap-orbitrap hybrid for peptide analysis
    • Yates JR, Cociorva D, Liao L, Zabrouskov V. 2006. Performance of a linear ion trap-orbitrap hybrid for peptide analysis. Anal Chem. 78:493-500.
    • (2006) Anal Chem , vol.78 , pp. 493-500
    • Yates, J.R.1    Cociorva, D.2    Liao, L.3    Zabrouskov, V.4
  • 235
    • 34547751263 scopus 로고    scopus 로고
    • Characterization of variable regions of monoclonal antibodies by top-down mass spectrometry
    • Zhang Z, Shah. B. 2007. Characterization of variable regions of monoclonal antibodies by top-down mass spectrometry. Anal Chem 79:5723-5729.
    • (2007) Anal Chem , vol.79 , pp. 5723-5729
    • Zhang, Z.1    Shah, B.2
  • 236
    • 35848937158 scopus 로고    scopus 로고
    • Detection and structural characterization of glutathione-trapped reactive metabolites using liquid chromatography-high-resolution mass spectrometry and mass defect filtering
    • Zhu M, Ma L, Zhang H, Humphreys WG. 2007. Detection and structural characterization of glutathione-trapped reactive metabolites using liquid chromatography-high-resolution mass spectrometry and mass defect filtering. Anal Chem 79:8333-8341.
    • (2007) Anal Chem , vol.79 , pp. 8333-8341
    • Zhu, M.1    Ma, L.2    Zhang, H.3    Humphreys, W.G.4
  • 238
    • 2742576125 scopus 로고    scopus 로고
    • Accuracy requirements for peptide characterization by monoisotopic molecular mass measurements
    • Zubarev RA, Hakansson P, Sundqvist B. 1996. Accuracy requirements for peptide characterization by monoisotopic molecular mass measurements. Anal Chem. 68:4060-4063.
    • (1996) Anal Chem , vol.68 , pp. 4060-4063
    • Zubarev, R.A.1    Hakansson, P.2    Sundqvist, B.3
  • 239
    • 0000944563 scopus 로고    scopus 로고
    • Electron capture dissociation of multiply charged protein cations. A nonergodic process
    • Zubarev RA, Kelleher NL, McLafferty FW. 1998. Electron capture dissociation of multiply charged protein cations. A nonergodic process. J Am Chem Soc 120:3265-3266.
    • (1998) J Am Chem Soc , vol.120 , pp. 3265-3266
    • Zubarev, R.A.1    Kelleher, N.L.2    McLafferty, F.W.3
  • 240
    • 0038610834 scopus 로고    scopus 로고
    • Reactions of polypeptide ions with electrons in the gas phase
    • Zubarev RA. 2003. Reactions of polypeptide ions with electrons in the gas phase. Mass Spectrom Rev 22:57-77.
    • (2003) Mass Spectrom Rev , vol.22 , pp. 57-77
    • Zubarev, R.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.