-
1
-
-
0017564248
-
Osseointegrated implants in the treatment of the edentulous jaw Experience from a 10-year period
-
Brånemark PI, Hansson BO, Adell R, Breine U, Lindström J, Hallén O, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl 1977; 16: 1-132.
-
(1977)
Scand J Plast Reconstr Surg Suppl
, vol.16
, pp. 1-132
-
-
Brånemark, P.I.1
Hansson, B.O.2
Adell, R.3
Breine, U.4
Lindström, J.5
Hallén, O.6
-
2
-
-
0348048837
-
Long-term evaluation of submerged and nonsubmerged ITI solid-screw titanium implants: A 10-year life table analysis of 468 implants
-
Lambrecht JT, Filippi A, Künzel AR, Schiel HJ. Long-term evaluation of submerged and nonsubmerged ITI solid-screw titanium implants: a 10-year life table analysis of 468 implants. Int J Oral Maxillofac Implants 2003; 18: 826-34.
-
(2003)
J Oral Maxillofac Implants
, vol.18
, pp. 826-834
-
-
Lambrecht, J.T.1
Filippi, A.2
Künzel, A.R.3
Schiel, H.J.4
-
3
-
-
77957880821
-
Modern dental imaging: A review of the current technology and clinical applications in dental practice
-
Vandenberghe B, Jacobs R, Bosmans H. Modern dental imaging: a review of the current technology and clinical applications in dental practice. Eur Radiol 2010; 20: 2637-55. doi: https:// doi. org/ 10. 1007/ s00330-010-1836-1
-
(2010)
Eur Radiol
, vol.20
, pp. 2637-2655
-
-
Vandenberghe, B.1
Jacobs, R.2
Bosmans, H.3
-
4
-
-
84899994950
-
Planning of dental implant size with digital panoramic radiographs, CBCT-generated panoramic images, and CBCT cross-sectional images
-
Correa LR, Spin-Neto R, Stavropoulos A, Schropp L, da Silveira HE, Wenzel A. Planning of dental implant size with digital panoramic radiographs, CBCT-generated panoramic images, and CBCT cross-sectional images. Clin Oral Implants Res 2014; 25: 690-5. doi: https:// doi. org/ 10. 1111/ clr. 12126
-
(2014)
Clin Oral Implants Res
, vol.25
, pp. 690-695
-
-
Correa, L.R.1
Spin-Neto, R.2
Stavropoulos, A.3
Schropp, L.4
Da Silveira, H.E.5
Wenzel, A.6
-
5
-
-
77955434105
-
Dental imaging in implant treatment planning
-
Chan HL, Misch K, Wang HL. Dental imaging in implant treatment planning. Implant Dent 2010; 19: 288-98. doi: https:// doi. org/ 10. 1097/ ID. 0b013e3181e59ebd
-
(2010)
Implant Dent
, vol.19
, pp. 288-298
-
-
Chan, H.L.1
Misch, K.2
Wang, H.L.3
-
6
-
-
84862561981
-
Position statement of the American Academy of Oral and Maxillofacial Radiology on selection criteria for the use of radiology in dental implantology with emphasis on cone beam computed tomography
-
Tyndall DA, Price JB, Tetradis S, Ganz SD, Hildebolt C, Scarfe WC, et al. Position statement of the American Academy of Oral and Maxillofacial Radiology on selection criteria for the use of radiology in dental implantology with emphasis on cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol 2012; 113: 817-26. doi: https:// doi. org/ 10. 1016/ j. oooo. 2012. 03. 005
-
(2012)
Oral Surg Oral Med Oral Pathol Oral Radiol
, vol.113
, pp. 817-826
-
-
Tyndall, D.A.1
Price, J.B.2
Tetradis, S.3
Ganz, S.D.4
Hildebolt, C.5
Scarfe, W.C.6
-
8
-
-
85018193592
-
Is cone-beam computed tomography always necessary for dental implant placement?
-
Deeb G, Antonos L, Tack S, Carrico C, Laskin D, Deeb JG. Is cone-beam computed tomography always necessary for dental implant placement? J Oral Maxillofac Surg 2017; 75: 285-9. doi: https:// doi. org/ 10. 1016/ j. joms. 2016. 11. 005
-
(2017)
J Oral Maxillofac Surg
, vol.75
, pp. 285-289
-
-
Deeb, G.1
Antonos, L.2
Tack, S.3
Carrico, C.4
Laskin, D.5
Deeb, J.G.6
-
9
-
-
85030852448
-
The use of cone-beam computed tomography in management of patients requiring dental implants: An American Academy of Periodontology best evidence review
-
Rios HF, Borgnakke WS, Benavides E. The use of cone-beam computed tomography in management of patients requiring dental implants: an American Academy of Periodontology best evidence review. J Periodontol 2017; 88: 946-59. doi: https:// doi. org/ 10. 1902/ jop. 2017. 160548
-
(2017)
J Periodontol
, vol.88
, pp. 946-959
-
-
Rios, H.F.1
Borgnakke, W.S.2
Benavides, E.3
-
10
-
-
84906722487
-
Digital vs conventional implant prosthetic workflows: A cost/time analysis
-
Joda T, Brägger U, vs D. Digital vs. conventional implant prosthetic workflows: a cost/time analysis. Clin Oral Implants Res 2015; 26: 1430-5. doi: https:// doi. org/ 10. 1111/ clr. 12476
-
(2015)
Clin Oral Implants Res
, vol.26
, pp. 1430-1435
-
-
Joda, T.1
Brägger, U.2
Vs, D.3
-
11
-
-
84862829660
-
Use of cone beam computed tomography in implant dentistry: The International Congress of Oral Implantologists consensus report
-
Benavides E, Rios HF, Ganz SD, An CH, Resnik R, Reardon GT, et al. Use of cone beam computed tomography in implant dentistry: the International Congress of Oral Implantologists consensus report. Implant Dent 2012; 21: 78-86. doi: https:// doi. org/ 10. 1097/ ID. 0b013e31824885b5
-
(2012)
Implant Dent
, vol.21
, pp. 78-86
-
-
Benavides, E.1
Rios, H.F.2
Ganz, S.D.3
An, C.H.4
Resnik, R.5
Reardon, G.T.6
-
12
-
-
85030855133
-
American Academy of Periodontology best evidence consensus statement on selected oral applications for cone-beam computed tomography
-
Mandelaris GA, Scheyer ET, Evans M, Kim D, McAllister B, Nevins ML, et al. American Academy of Periodontology best evidence consensus statement on selected oral applications for cone-beam computed tomography. J Periodontol 2017; 88: 939-45 doi: https:// doi. org/ 10. 1902/ jop. 2017. 170234
-
(2017)
J Periodontol
, vol.88
, pp. 939-945
-
-
Mandelaris, G.A.1
Scheyer, E.T.2
Evans, M.3
Kim, D.4
McAllister, B.5
Nevins, M.L.6
-
13
-
-
85011960876
-
Non-invasive evaluation of facial crestal bone with ultrasonography
-
Chan HL, Sinjab K, Chung MP, Chiang YC, Wang HL, Giannobile WV, et al. Non-invasive evaluation of facial crestal bone with ultrasonography. PLoS One 2017; 12: e0171237. doi: https:// doi. org/ 10. 1371/ journal. pone. 0171237
-
(2017)
PLoS One
, vol.12
, pp. e0171237
-
-
Chan, H.L.1
Sinjab, K.2
Chung, M.P.3
Chiang, Y.C.4
Wang, H.L.5
Giannobile, W.V.6
-
14
-
-
84961226979
-
Non-ionizing real-time ultrasonography in implant and oral surgery: A feasibility study
-
Chan HL, Wang HL, Fowlkes JB, Giannobile WV, Kripfgans OD. Non-ionizing real-time ultrasonography in implant and oral surgery: A feasibility study. Clin Oral Implants Res 2017; 28: 341-7 doi: https:// doi. org/ 10. 1111/ clr. 12805
-
(2017)
Clin Oral Implants Res
, vol.28
, pp. 341-347
-
-
Chan, H.L.1
Wang, H.L.2
Fowlkes, J.B.3
Giannobile, W.V.4
Kripfgans, O.D.5
-
15
-
-
84878281934
-
Recent advances of ultrasound imaging in dentistry-A review of the literature
-
Marotti J, Heger S, Tinschert J, Tortamano P, Chuembou F, Radermacher K, et al. Recent advances of ultrasound imaging in dentistry-A review of the literature. Oral Surg Oral Med Oral Pathol Oral Radiol 2013; 1115: 819-32. doi: https:// doi. org/ 10. 1016/ j. oooo. 2013. 03. 012
-
(2013)
Oral Surg Oral Med Oral Pathol Oral Radiol
, vol.1115
, pp. 819-832
-
-
Marotti, J.1
Heger, S.2
Tinschert, J.3
Tortamano, P.4
Chuembou, F.5
Radermacher, K.6
-
16
-
-
84988527205
-
Imaging the cemento-enamel junction using a 20-MHz ultrasoni transducer
-
Nguyen KC, Le LH, Kaipatur NR, Major PW. Imaging the cemento-enamel junction using a 20-MHz ultrasoni transducer. Ultrasound Med Biol 2016; 42: 333-8. doi: https:// doi. org/ 10. 1016/ j. ultrasmedbio. 2015. 09. 012
-
(2016)
Ultrasound Med Biol
, vol.42
, pp. 333-338
-
-
Nguyen, K.C.1
Le, L.H.2
Kaipatur, N.R.3
Major, P.W.4
-
17
-
-
84966600857
-
High-resolution ultrasonic imaging of dento-periodontal tissues using a multi-element phased array system
-
Nguyen KT, Le LH, Kaipatur NR, Zheng R, Lou EH, Major PW. High-resolution ultrasonic imaging of dento-periodontal tissues using a multi-element phased array system. Ann Biomed Eng 2016; 44: 2874-86. doi: https:// doi. org/ 10. 1007/ s10439-016-1634-2
-
(2016)
Ann Biomed Eng
, vol.44
, pp. 2874-2886
-
-
Nguyen, K.T.1
Le, L.H.2
Kaipatur, N.R.3
Zheng, R.4
Lou, E.H.5
Major, P.W.6
-
18
-
-
84905506994
-
Surgical management of peri-implantitis: A systematic review and meta-analysis of treatment outcomes
-
Chan HL, Lin GH, Suarez F, MacEachern M, Wang HL. Surgical management of peri-implantitis: a systematic review and meta-analysis of treatment outcomes. J Periodontol 2014; 85: 1027-41. doi: https:// doi. org/ 10. 1902/ jop. 2013. 130563
-
(2014)
J Periodontol
, vol.85
, pp. 1027-1041
-
-
Chan, H.L.1
Lin, G.H.2
Suarez, F.3
MacEachern, M.4
Wang, H.L.5
-
19
-
-
84887442708
-
Reconstructive procedures for treating peri-implantitis: A systematic review
-
Khoshkam V, Chan HL, Lin GH, MacEachern MP, Monje A, Suarez F, et al. Reconstructive procedures for treating peri-implantitis: a systematic review. J Dent Res 2013; 92(12 Suppl): 131S-8. doi: https:// doi. org/ 10. 1177/ 0022034513509279
-
(2013)
J Dent Res
, vol.92
, Issue.12
, pp. 8-131S
-
-
Khoshkam, V.1
Chan, H.L.2
Lin, G.H.3
MacEachern, M.P.4
Monje, A.5
Suarez, F.6
-
20
-
-
84925987335
-
Peri-implant health and disease A systematic review of current epidemiology
-
Derks J, Tomasi C. Peri-implant health and disease. A systematic review of current epidemiology. J Clin Periodontol 2015; 42(Suppl 16): S158-S171. doi: https:// doi. org/ 10. 1111/ jcpe. 12334
-
(2015)
J Clin Periodontol
, vol.42
, pp. S158-S171
-
-
Derks, J.1
Tomasi, C.2
-
22
-
-
84880214656
-
Evaluation of ultrasound transmission velocity and 3-dimensional radiology in different bone types for dental implantology: A comparative ex vivo study
-
Kämmerer PW, Kumar VV, Brüllmann D, Götz H, Kann PH, Al-Nawas B, et al. Evaluation of ultrasound transmission velocity and 3-dimensional radiology in different bone types for dental implantology: a comparative ex vivo study. Oral Surg Oral Med Oral Pathol Oral Radiol 2013; 116: e77-e84. doi: https:// doi. org/ 10. 1016/ j. oooo. 2011. 11. 028
-
(2013)
Oral Surg Oral Med Oral Pathol Oral Radiol
, vol.116
, pp. e77-e84
-
-
Kämmerer, P.W.1
Kumar, V.V.2
Brüllmann, D.3
Götz, H.4
Kann, P.H.5
Al-Nawas, B.6
-
23
-
-
56549096022
-
Ultrasound transmission velocity for noninvasive evaluation of jaw bone quality in vivo before dental implantation
-
Klein MO, Grötz KA, Manefeld B, Kann PH, Al-Nawas B. Ultrasound transmission velocity for noninvasive evaluation of jaw bone quality in vivo before dental implantation. Ultrasound Med Biol 2008; 34: 1966-71. doi: https:// doi. org/ 10. 1016/ j. ultrasmedbio. 2008. 04. 016
-
(2008)
Ultrasound Med Biol
, vol.34
, pp. 1966-1971
-
-
Klein, M.O.1
Grötz, K.A.2
Manefeld, B.3
Kann, P.H.4
Al-Nawas, B.5
-
24
-
-
79959456575
-
Numerical simulation of ultrasonic wave propagation for the evaluation of dental implant biomechanical stability
-
Mathieu V, Anagnostou F, Soffer E, Haiat G. Numerical simulation of ultrasonic wave propagation for the evaluation of dental implant biomechanical stability. J Acoust Soc Am 2011; 129: 4062-72. doi: https:// doi. org/ 10. 1121/ 1. 3586788
-
(2011)
J Acoust Soc Am
, vol.129
, pp. 4062-4072
-
-
Mathieu, V.1
Anagnostou, F.2
Soffer, E.3
Haiat, G.4
-
25
-
-
78751607977
-
Ultrasonic evaluation of dental implant biomechanical stability: An in vitro study
-
Mathieu V, Anagnostou F, Soffer E, Haïat G. Ultrasonic evaluation of dental implant biomechanical stability: an in vitro study. Ultrasound Med Biol 2011; 37: 262-70. doi: https:// doi. org/ 10. 1016/ j. ultrasmedbio. 2010. 10. 008
-
(2011)
Ultrasound Med Biol
, vol.37
, pp. 262-270
-
-
Mathieu, V.1
Anagnostou, F.2
Soffer, E.3
Haïat, G.4
-
26
-
-
84875375725
-
Variation of the ultrasonic response of a dental implant embedded in tricalcium silicate-based cement under cyclic loading
-
Vayron R, Karasinski P, Mathieu V, Michel A, Loriot D, Richard G, et al. Variation of the ultrasonic response of a dental implant embedded in tricalcium silicate-based cement under cyclic loading. J Biomech 2013; 46: 1162-8. doi: https:// doi. org/ 10. 1016/ j. jbiomech. 2013. 01. 003
-
(2013)
J Biomech
, vol.46
, pp. 1162-1168
-
-
Vayron, R.1
Karasinski, P.2
Mathieu, V.3
Michel, A.4
Loriot, D.5
Richard, G.6
-
27
-
-
37249012547
-
Sonography of periimplant buccal bone defects in periodontitis patients: A pilot study
-
Bertram S, Emshoff R. Sonography of periimplant buccal bone defects in periodontitis patients: A pilot study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 105: 99-103. doi: https:// doi. org/ 10. 1016/ j. tripleo. 2007. 01. 014
-
(2008)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.105
, pp. 99-103
-
-
Bertram, S.1
Emshoff, R.2
-
28
-
-
39749175698
-
Ultrasound detection of submerged dental implants through soft tissue in a porcine model
-
Culjat MO, Choi M, Singh RS, Grundfest WS, Brown ER, White SN. Ultrasound detection of submerged dental implants through soft tissue in a porcine model. J Prosthet Dent 2008; 99: 218-24. doi: https:// doi. org/ 10. 1016/ S0022-3913(08)60046-3
-
(2008)
J Prosthet Dent
, vol.99
, pp. 218-224
-
-
Culjat, M.O.1
Choi, M.2
Singh, R.S.3
Grundfest, W.S.4
Brown, E.R.5
White, S.N.6
-
30
-
-
84943360345
-
Horizontal stability of connective tissue grafts at the buccal aspect of single implants: A 1-year prospective case series
-
De Bruyckere T, Eghbali A, Younes F, De Bruyn H, Cosyn J. Horizontal stability of connective tissue grafts at the buccal aspect of single implants: a 1-year prospective case series. J Clin Periodontol 2015; 42: 876-82. doi: https:// doi. org/ 10. 1111/ jcpe. 12448
-
(2015)
J Clin Periodontol
, vol.42
, pp. 876-882
-
-
De Bruyckere, T.1
Eghbali, A.2
Younes, F.3
De Bruyn, H.4
Cosyn, J.5
-
31
-
-
84961732889
-
Assessment of cortical bone thickness using ultrasound
-
Degen K, Habor D, Radermacher K, Heger S, Kern JS, Wolfart S, et al. Assessment of cortical bone thickness using ultrasound. Clin Oral Implants Res 2017; 28: 520-8. doi: https:// doi. org/ 10. 1111/ clr. 12829
-
(2017)
Clin Oral Implants Res
, vol.28
, pp. 520-528
-
-
Degen, K.1
Habor, D.2
Radermacher, K.3
Heger, S.4
Kern, J.S.5
Wolfart, S.6
-
32
-
-
84955597516
-
Ultrasonic assessment of mucosal thickness around implants: Validity, reproducibility, and stability of connective tissue grafts at the buccal aspect
-
Eghbali A, De Bruyn H, Cosyn J, Kerckaert I, Van Hoof T. Ultrasonic assessment of mucosal thickness around implants: validity, reproducibility, and stability of connective tissue grafts at the buccal aspect. Clin Implant Dent Relat Res 2016; 18: 51-61. doi: https:// doi. org/ 10. 1111/ cid. 12245
-
(2016)
Clin Implant Dent Relat Res
, vol.18
, pp. 51-61
-
-
Eghbali, A.1
De Bruyn, H.2
Cosyn, J.3
Kerckaert, I.4
Van Hoof, T.5
-
33
-
-
84863868151
-
Relation between bone quality values from ultrasound transmission velocity and implant stability parameters-an ex vivo study
-
Kumar VV, Sagheb K, Klein MO, Al-Nawas B, Kann PH, Kämmerer PW. Relation between bone quality values from ultrasound transmission velocity and implant stability parameters-an ex vivo study. Clin Oral Implants Res 2012; 23: 975-80. doi: https:// doi. org/ 10. 1111/ j. 1600-0501. 2011. 02250.x
-
(2012)
Clin Oral Implants Res
, vol.23
, pp. 975-980
-
-
Kumar, V.V.1
Sagheb, K.2
Klein, M.O.3
Al-Nawas, B.4
Kann, P.H.5
Kämmerer, P.W.6
-
34
-
-
0242691645
-
Ultrasound identification and quantitative measurement of blood supply to the anterior part of the mandible
-
Lustig JP, London D, Dor BL, Yanko R. Ultrasound identification and quantitative measurement of blood supply to the anterior part of the mandible. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2003; 96: 625-9. doi: https:// doi. org/ 10. 1016/ j. tripleo. 2003. 08. 015
-
(2003)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.96
, pp. 625-629
-
-
Lustig, J.P.1
London, D.2
Dor, B.L.3
Yanko, R.4
-
35
-
-
77954477109
-
Novel ultrasonic device to measure the distance from the bottom of the osteotome to various anatomic landmarks
-
Machtei EE, Zigdon H, Levin L, Peled M. Novel ultrasonic device to measure the distance from the bottom of the osteotome to various anatomic landmarks. J Periodontol 2010; 81: 1051-5. doi: https:// doi. org/ 10. 1902/ jop. 2010. 090621
-
(2010)
J Periodontol
, vol.81
, pp. 1051-1055
-
-
Machtei, E.E.1
Zigdon, H.2
Levin, L.3
Peled, M.4
-
36
-
-
84858255001
-
In vitro assessment of bone-implant interface using an acoustic emission transmission test
-
Ossi Z, Abdou W, Reuben RL, Ibbetson RJ. In vitro assessment of bone-implant interface using an acoustic emission transmission test. Proc Inst Mech Eng H 2012; 226: 63-9. doi: https:// doi. org/ 10. 1177/ 0954411911428696
-
(2012)
Proc Inst Mech Eng H
, vol.226
, pp. 63-69
-
-
Ossi, Z.1
Abdou, W.2
Reuben, R.L.3
Ibbetson, R.J.4
-
37
-
-
84890536037
-
Transmission of acoustic emission in bones, implants and dental materials
-
Ossi Z, Abdou W, Reuben RL, Ibbetson RJ. Transmission of acoustic emission in bones, implants and dental materials. Proc Inst Mech Eng H 2013; 227: 1237-45. doi: https:// doi. org/ 10. 1177/ 0954411913500204
-
(2013)
Proc Inst Mech Eng H
, vol.227
, pp. 1237-1245
-
-
Ossi, Z.1
Abdou, W.2
Reuben, R.L.3
Ibbetson, R.J.4
-
38
-
-
84888866667
-
Intraosseous monitoring and guiding by ultrasound: A feasibility study
-
Rosenberg N, Craft A, Halevy-Politch J. Intraosseous monitoring and guiding by ultrasound: a feasibility study. Ultrasonics 2014; 54: 710-9. doi: https:// doi. org/ 10. 1016/ j. ultras. 2013. 09. 008
-
(2014)
Ultrasonics
, vol.54
, pp. 710-719
-
-
Rosenberg, N.1
Craft, A.2
Halevy-Politch, J.3
-
39
-
-
84858706896
-
Intraoral ultrasonography: Development of a specific high-frequency probe and clinical pilot study
-
Salmon B, Le Denmat D. Intraoral ultrasonography: development of a specific high-frequency probe and clinical pilot study. Clin Oral Investig 2012; 16: 643-9. doi: https:// doi. org/ 10. 1007/ s00784-011-0533-z
-
(2012)
Clin Oral Investig
, vol.16
, pp. 643-649
-
-
Salmon, B.1
Le Denmat, D.2
-
40
-
-
84964129432
-
Ultrasonographic measurement of the soft-tissue of the upper jaw
-
Traxler M, Solar P, Ulm C, Gritzmann N. Ultrasonographic measurement of the soft-tissue of the upper jaw. Acta Radiol 1991; 32: 3-5. doi: https:// doi. org/ 10. 1177/ 028418519103200102
-
(1991)
Acta Radiol
, vol.32
, pp. 3-5
-
-
Traxler, M.1
Solar, P.2
Ulm, C.3
Gritzmann, N.4
-
41
-
-
0026828242
-
Sonographic measurement versus mapping for determination of residual ridge width
-
Traxler M, Ulm C, Solar P, Lill W. Sonographic measurement versus mapping for determination of residual ridge width. J Prosthet Dent 1992; 67: 358-61. doi: https:// doi. org/ 10. 1016/ 0022-3913(92)90246-7
-
(1992)
J Prosthet Dent
, vol.67
, pp. 358-361
-
-
Traxler, M.1
Ulm, C.2
Solar, P.3
Lill, W.4
-
42
-
-
84896753999
-
Assessment of in vitro dental implant primary stability using an ultrasonic method
-
Vayron R, Mathieu V, Michel A, Haïat G. Assessment of in vitro dental implant primary stability using an ultrasonic method. Ultrasound Med Biol 2014; 40: 2885-94. doi: https:// doi. org/ 10. 1016/ j. ultrasmedbio. 2014. 03. 035
-
(2014)
Ultrasound Med Biol
, vol.40
, pp. 2885-2894
-
-
Vayron, R.1
Mathieu, V.2
Michel, A.3
Haïat, G.4
-
43
-
-
84941317964
-
Finite element simulation of ultrasonic wave propagation in a dental implant for biomechanical stability assessment
-
Vayron R, Nguyen VH, Bosc R, Naili S, Haïat G. Finite element simulation of ultrasonic wave propagation in a dental implant for biomechanical stability assessment. Biomech Model Mechanobiol 2015; 14: 1021-32. doi: https:// doi. org/ 10. 1007/ s10237-015-0651-7
-
(2015)
Biomech Model Mechanobiol
, vol.14
, pp. 1021-1032
-
-
Vayron, R.1
Nguyen, V.H.2
Bosc, R.3
Naili, S.4
Haïat, G.5
-
44
-
-
84958555106
-
Assessment of the biomechanical stability of a dental implant with quantitative ultrasound: A three-dimensional finite element study
-
Vayron R, Nguyen VH, Bosc R, Naili S, Haïat G. Assessment of the biomechanical stability of a dental implant with quantitative ultrasound: a three-dimensional finite element study. J Acoust Soc Am 2016; 139: 773-80. doi: https:// doi. org/ 10. 1121/ 1. 4941452
-
(2016)
J Acoust Soc Am
, vol.139
, pp. 773-780
-
-
Vayron, R.1
Nguyen, V.H.2
Bosc, R.3
Naili, S.4
Haïat, G.5
-
45
-
-
84920280926
-
Ultrasonic evaluation of dental implant osseointegration
-
Vayron R, Soffer E, Anagnostou F, Haïat G. Ultrasonic evaluation of dental implant osseointegration. J Biomech 2014; 47: 3562-8. doi: https:// doi. org/ 10. 1016/ j. jbiomech. 2014. 07. 011
-
(2014)
J Biomech
, vol.47
, pp. 3562-3568
-
-
Vayron, R.1
Soffer, E.2
Anagnostou, F.3
Haïat, G.4
-
46
-
-
77954567514
-
The speed of sound correlates with implant insertion torque in rabbit bone: An in vitro experiment
-
Veltri M, Valenti R, Ceccarelli E, Balleri P, Nuti R, Ferrari M. The speed of sound correlates with implant insertion torque in rabbit bone: an in vitro experiment. Clin Oral Implants Res 2010; 21: 751-5. doi: https:// doi. org/ 10. 1111/ j. 1600-0501. 2009. 01873.x
-
(2010)
Clin Oral Implants Res
, vol.21
, pp. 751-755
-
-
Veltri, M.1
Valenti, R.2
Ceccarelli, E.3
Balleri, P.4
Nuti, R.5
Ferrari, M.6
-
47
-
-
84989220919
-
Intraoperative measurement of the distance from the bottom of osteotomy to the mandibular canal using a novel ultrasonic device
-
Zigdon-Giladi H, Saminsky M, Elimelech R, Machtei EE. Intraoperative measurement of the distance from the bottom of osteotomy to the mandibular canal using a novel ultrasonic device. Clin Implant Dent Relat Res 2016; 18: 1034-41. doi: https:// doi. org/ 10. 1111/ cid. 12362
-
(2016)
Clin Implant Dent Relat Res
, vol.18
, pp. 1034-1041
-
-
Zigdon-Giladi, H.1
Saminsky, M.2
Elimelech, R.3
Machtei, E.E.4
-
48
-
-
77950688388
-
Tissue biotype and its relation to the underlying bone morphology
-
Fu JH, Yeh CY, Chan HL, Tatarakis N, Leong DJ, Wang HL. Tissue biotype and its relation to the underlying bone morphology. J Periodontol 2010; 81: 569-74. doi: https:// doi. org/ 10. 1902/ jop. 2009. 090591
-
(2010)
J Periodontol
, vol.81
, pp. 569-574
-
-
Fu, J.H.1
Yeh, C.Y.2
Chan, H.L.3
Tatarakis, N.4
Leong, D.J.5
Wang, H.L.6
-
49
-
-
65649152915
-
Instant provisionalization of immediate single-tooth implants is essential to optimize esthetic treatment outcome
-
De Rouck T, Collys K, Wyn I, Cosyn J. Instant provisionalization of immediate single-tooth implants is essential to optimize esthetic treatment outcome. Clin Oral Implants Res 2009; 20: 566-570. doi: https:// doi. org/ 10. 1111/ j. 1600-0501. 2008. 01674.x
-
(2009)
Clin Oral Implants Res
, vol.20
, pp. 566-570
-
-
De Rouck, T.1
Collys, K.2
Wyn, I.3
Cosyn, J.4
-
50
-
-
77956027869
-
Gingival biotype assessment in the esthetic zone: Visual versus direct measurement
-
Kan JY, Morimoto T, Rungcharassaeng K, Roe P, Smith DH. Gingival biotype assessment in the esthetic zone: visual versus direct measurement. Int J Periodontics Restorative Dent 2010; 30: 237-43.
-
(2010)
J Periodontics Restorative Dent
, vol.30
, pp. 237-243
-
-
Kan, J.Y.1
Morimoto, T.2
Rungcharassaeng, K.3
Roe, P.4
Smith, D.H.5
-
51
-
-
84883865983
-
Effect of flapless surgery on single-tooth implants in the esthetic zone: A randomized clinical trial
-
Bashutski JD, Wang HL, Rudek I, Moreno I, Koticha T, Oh TJ,. Effect of flapless surgery on single-tooth implants in the esthetic zone: a randomized clinical trial. J Periodontol 2013; 84: 1747-54. doi: https:// doi. org/ 10. 1902/ jop. 2013. 120575
-
(2013)
J Periodontol
, vol.84
, pp. 1747-1754
-
-
Bashutski, J.D.1
Wang, H.L.2
Rudek, I.3
Moreno, I.4
Koticha, T.5
Oh, T.J.6
-
52
-
-
84984996882
-
Comparison of clinical and radiographic outcomes of platform-switched implants with a rough collar and platform-matched implants with a smooth collar: A 1-year randomized clinical trial
-
Hsu YT, Chan HL, Rudek I, Bashutski J, Oh WS, Wang HL, et al. Comparison of clinical and radiographic outcomes of platform-switched implants with a rough collar and platform-matched implants with a smooth collar: a 1-year randomized clinical trial. Int J Oral Maxillofac Implants 2016; 31: 382-90. doi: https:// doi. org/ 10. 11607/ jomi. 4189
-
(2016)
J Oral Maxillofac Implants
, vol.31
, pp. 382-390
-
-
Hsu, Y.T.1
Chan, H.L.2
Rudek, I.3
Bashutski, J.4
Oh, W.S.5
Wang, H.L.6
-
53
-
-
33847745491
-
Flapless implant surgery in the esthetic region: Advantages and precautions
-
Oh TJ, Shotwell J, Billy E, Byun HY, Wang HL. Flapless implant surgery in the esthetic region: advantages and precautions. Int J Periodontics Restorative Dent 2007; 27: 27-33.
-
(2007)
J Periodontics Restorative Dent
, vol.27
, pp. 27-33
-
-
Oh, T.J.1
Shotwell, J.2
Billy, E.3
Byun, H.Y.4
Wang, H.L.5
-
54
-
-
78650530132
-
Implant primary stability determined by resonance frequency analysis in surgically created defects: A pilot cadaver study
-
Chan HL, El-Kholy K, Fu JH, Galindo-Moreno P, Wang HL. Implant primary stability determined by resonance frequency analysis in surgically created defects: a pilot cadaver study. Implant Dent 2010; 19: 509-19. doi: https:// doi. org/ 10. 1097/ ID. 0b013e3181fa7f6a
-
(2010)
Implant Dent
, vol.19
, pp. 509-519
-
-
Chan, H.L.1
El-Kholy, K.2
Fu, J.H.3
Galindo-Moreno, P.4
Wang, H.L.5
|