-
1
-
-
33748309280
-
Validity and clinical significance of biomechanical testing of implant/bone interface
-
Aparicio C, Lang NR, Rangert B (2006) Validity and clinical significance of biomechanical testing of implant/bone interface. Clin Oral Implant Res 17:2–7
-
(2006)
Clin Oral Implant Res
, vol.17
, pp. 2-7
-
-
Aparicio, C.1
Lang, N.R.2
Rangert, B.3
-
2
-
-
84859915140
-
Experimental evidence of impingement induced strains at the interface and the periphery of an embedded acetabular cup implant
-
Arndt C, Voigt C, Steinke H, von Salis-Soglio G, Scholz R (2012) Experimental evidence of impingement induced strains at the interface and the periphery of an embedded acetabular cup implant. J Biomech Eng T ASME 134
-
(2012)
J Biomech Eng T ASME
, pp. 134
-
-
Arndt, C.1
Voigt, C.2
Steinke, H.3
von Salis-Soglio, G.4
Scholz, R.5
-
3
-
-
25444498330
-
A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants
-
Balshi SF, Allen FD, Wolfinger GJ, Balshi TJ (2005) A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants. Int J Oral Maxillofac Implants 20:584–594
-
(2005)
Int J Oral Maxillofac Implants
, vol.20
, pp. 584-594
-
-
Balshi, S.F.1
Allen, F.D.2
Wolfinger, G.J.3
Balshi, T.J.4
-
4
-
-
77949905454
-
Quantifying the influence of bone density and thickness on resonance frequency analysis: an in vitro study of biomechanical test materials
-
Bardyn T, Gedet P, Hallermann W, Buchler P (2009) Quantifying the influence of bone density and thickness on resonance frequency analysis: an in vitro study of biomechanical test materials. Int J Oral Maxillofac Implants 24:1006–1014
-
(2009)
Int J Oral Maxillofac Implants
, vol.24
, pp. 1006-1014
-
-
Bardyn, T.1
Gedet, P.2
Hallermann, W.3
Buchler, P.4
-
5
-
-
78650203348
-
Influence on early osseointegration of dental implants installed with two different drilling protocols: a histomorphometric study in rabbit
-
Blanco J, Alvarez E, Munoz F, Linares A, Cantalapiedra A (2011) Influence on early osseointegration of dental implants installed with two different drilling protocols: a histomorphometric study in rabbit. Clin Oral Implants Res 22:92–99
-
(2011)
Clin Oral Implants Res
, vol.22
, pp. 92-99
-
-
Blanco, J.1
Alvarez, E.2
Munoz, F.3
Linares, A.4
Cantalapiedra, A.5
-
6
-
-
35948976118
-
A 10-year prospective study of ITI dental implants placed in the posterior region. I: clinical and radiographic results
-
Blanes RJ, Bernard JP, Blanes ZM, Belser UC (2007) A 10-year prospective study of ITI dental implants placed in the posterior region. I: clinical and radiographic results. Clin Oral Implants Res 18:699–706
-
(2007)
Clin Oral Implants Res
, vol.18
, pp. 699-706
-
-
Blanes, R.J.1
Bernard, J.P.2
Blanes, Z.M.3
Belser, U.C.4
-
7
-
-
68349122619
-
Influence of the orientation of the Osstell transducer during measurement of dental implant stability using resonance frequency analysis: a numerical approach
-
Capek L, Simunek A, Slezak R, Dzan L (2009) Influence of the orientation of the Osstell transducer during measurement of dental implant stability using resonance frequency analysis: a numerical approach. Med Eng Phys 31:764–769. doi:10.1016/j.medengphy.2009.02.003
-
(2009)
Med Eng Phys
, vol.31
, pp. 764-769
-
-
Capek, L.1
Simunek, A.2
Slezak, R.3
Dzan, L.4
-
8
-
-
0038386256
-
Elasticity of alveolar bone near dental implant–bone interfaces after one month’s healing
-
Chang MC et al (2003) Elasticity of alveolar bone near dental implant–bone interfaces after one month’s healing. J Biomech 36:1209–1214. doi:10.1016/s0021-9290(03)001133-1
-
(2003)
J Biomech
, vol.36
, pp. 1209-1214
-
-
Chang, M.C.1
-
9
-
-
77953344351
-
Biomechanical evaluation of endosseous implants at early implantation times: a study in dogs
-
Coelho PG et al (2010) Biomechanical evaluation of endosseous implants at early implantation times: a study in dogs. J Oral Maxillofac Surg 68:1667–1675
-
(2010)
J Oral Maxillofac Surg
, vol.68
, pp. 1667-1675
-
-
Coelho, P.G.1
-
10
-
-
34547635232
-
Proposal for an ultrasonic tool to monitor the osseointegration of dental implants
-
de Almeida MS, Maciel CD, Pereira JC (2007) Proposal for an ultrasonic tool to monitor the osseointegration of dental implants. Sensors 7:1224–1237
-
(2007)
Sensors
, vol.7
, pp. 1224-1237
-
-
de Almeida, M.S.1
Maciel, C.D.2
Pereira, J.C.3
-
11
-
-
34249774606
-
Influence of different implant surfaces on peri-implant osteogenesis: histomorphometric analysis in sheep
-
Franchi M et al (2007) Influence of different implant surfaces on peri-implant osteogenesis: histomorphometric analysis in sheep. J Periodontol 78:879–888
-
(2007)
J Periodontol
, vol.78
, pp. 879-888
-
-
Franchi, M.1
-
13
-
-
84860544504
-
Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips
-
Gill A, Shellock FG (2012) Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips. J Cardiov Magn Reson 14
-
(2012)
J Cardiov Magn Reson
, pp. 14
-
-
Gill, A.1
Shellock, F.G.2
-
14
-
-
4644230057
-
Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading: successful vs. failing implants
-
Glauser R, Sennerby L, Meredith N, Ree A, Lundgren A, Gottlow J, Hammerle CHF (2004) Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading: successful vs. failing implants. Clin Oral Implant Res 15:428–434
-
(2004)
Clin Oral Implant Res
, vol.15
, pp. 428-434
-
-
Glauser, R.1
Sennerby, L.2
Meredith, N.3
Ree, A.4
Lundgren, A.5
Gottlow, J.6
Hammerle, C.H.F.7
-
15
-
-
79954504228
-
Equivalent contributing depth investigated by a lateral wave with axial transmission in viscoelastic cortical bone
-
Haïat G, Naili S, Vu MB, Desceliers C, Soize C (2011) Equivalent contributing depth investigated by a lateral wave with axial transmission in viscoelastic cortical bone. J Acoust Soc Am 129:114–120
-
(2011)
J Acoust Soc Am
, vol.129
, pp. 114-120
-
-
Haïat, G.1
Naili, S.2
Vu, M.B.3
Desceliers, C.4
Soize, C.5
-
16
-
-
67649090655
-
Influence of a gradient of material properties on ultrasonic wave propagation in cortical bone: application to axial transmission
-
Haïat G, Naili S, Grimal Q, Talmant M, Desceliers C, Soize C (2009) Influence of a gradient of material properties on ultrasonic wave propagation in cortical bone: application to axial transmission. J Acoust Soc Am 125:4043–4052
-
(2009)
J Acoust Soc Am
, vol.125
, pp. 4043-4052
-
-
Haïat, G.1
Naili, S.2
Grimal, Q.3
Talmant, M.4
Desceliers, C.5
Soize, C.6
-
17
-
-
79954504228
-
Equivalent contributing depth investigated by a lateral wave with axial transmission in heterogeneous viscoelastic cortical bone
-
Haïat G, Naili S, Vu M-B, Desceliers C, Soize C (2011) Equivalent contributing depth investigated by a lateral wave with axial transmission in heterogeneous viscoelastic cortical bone. J Acoust Soc Am 129:EL114–EL120
-
(2011)
J Acoust Soc Am
, vol.129
, pp. 114-120
-
-
Haïat, G.1
Naili, S.2
Vu, M.-B.3
Desceliers, C.4
Soize, C.5
-
18
-
-
40749098888
-
Fast wave propagation in trabecular bone: numerical study of the influence of porosity and structural anisotropy
-
Haïat G, Padilla F, Laugier P (2008) Fast wave propagation in trabecular bone: numerical study of the influence of porosity and structural anisotropy. J Acoust Soc Am 123:194–705
-
(2008)
J Acoust Soc Am
, vol.123
, pp. 194-705
-
-
Haïat, G.1
Padilla, F.2
Laugier, P.3
-
19
-
-
34447529339
-
Variation of ultrasonic parameters with microstructure and material properties of trabecular bone: a 3D model simulation
-
Haïat G, Padilla F, Peyrin F, Laugier P (2007) Variation of ultrasonic parameters with microstructure and material properties of trabecular bone: a 3D model simulation. J Bone Miner Res 22:665–674
-
(2007)
J Bone Miner Res
, vol.22
, pp. 665-674
-
-
Haïat, G.1
Padilla, F.2
Peyrin, F.3
Laugier, P.4
-
20
-
-
84896778286
-
Effects of biomechanical properties of the bone-implant interface on dental implant stability: from in silico approaches to the patient’s mouth
-
Haïat G, Wang HL, Brunski JB (2014) Effects of biomechanical properties of the bone-implant interface on dental implant stability: from in silico approaches to the patient’s mouth. Annu Rev Biomed Eng 16:187–213
-
(2014)
Annu Rev Biomed Eng
, vol.16
, pp. 187-213
-
-
Haïat, G.1
Wang, H.L.2
Brunski, J.B.3
-
21
-
-
77957591997
-
The finite element method: linear static and dynamic finite element analysis. Dover civil and mechanical engineering
-
Mineola, New York
-
Hughes TJR (2000) The finite element method: linear static and dynamic finite element analysis. Dover civil and mechanical engineering. Dover Publications, Mineola, New York
-
(2000)
Dover Publications
-
-
Hughes, T.J.R.1
-
22
-
-
0033053640
-
Microdamage adjacent to endosseous implants
-
Huja SS, Katona TR, Burr DB, Garetto LP, Roberts WE (1999) Microdamage adjacent to endosseous implants. Bone 25:217–222
-
(1999)
Bone
, vol.25
, pp. 217-222
-
-
Huja, S.S.1
Katona, T.R.2
Burr, D.B.3
Garetto, L.P.4
Roberts, W.E.5
-
24
-
-
0033104477
-
The effect of surface roughness on the stress adaptation of trabecular architecture around a cylindrical implant
-
Luo GM, Sadegh AM, Alexander H, Jaffe W, Scott D, Cowin SC (1999) The effect of surface roughness on the stress adaptation of trabecular architecture around a cylindrical implant. J Biomech 32:275–284
-
(1999)
J Biomech
, vol.32
, pp. 275-284
-
-
Luo, G.M.1
Sadegh, A.M.2
Alexander, H.3
Jaffe, W.4
Scott, D.5
Cowin, S.C.6
-
25
-
-
79959456575
-
Numerical simulation of ultrasonic wave propagation for the evaluation of dental implant biomechanical stability
-
Mathieu V, Anagnostou F, Soffer E, Haiat G (2011a) Numerical simulation of ultrasonic wave propagation for the evaluation of dental implant biomechanical stability. J Acoust Soc Am 129:4062–4072
-
(2011)
J Acoust Soc Am
, vol.129
, pp. 4062-4072
-
-
Mathieu, V.1
Anagnostou, F.2
Soffer, E.3
Haiat, G.4
-
26
-
-
78751607977
-
Ultrasonic evaluation of dental implant biomechanical stability: an in vitro study
-
Mathieu V, Anagnostou F, Soffer E, Haiat G (2011b) Ultrasonic evaluation of dental implant biomechanical stability: an in vitro study. Ultrasound Med Biol 37:262–270
-
(2011)
Ultrasound Med Biol
, vol.37
, pp. 262-270
-
-
Mathieu, V.1
Anagnostou, F.2
Soffer, E.3
Haiat, G.4
-
27
-
-
78751692204
-
Micro-Brillouin scattering measurements in mature and newly formed bone tissue surrounding an implant
-
Mathieu V et al (2011c) Micro-Brillouin scattering measurements in mature and newly formed bone tissue surrounding an implant. J Biomech Eng T ASME 133:021006–021006
-
(2011)
J Biomech Eng T ASME
, vol.133
, pp. 021006
-
-
Mathieu, V.1
-
28
-
-
84890855537
-
Biomechanical determinants of the stability of dental implants: influence of the bone–implant interface properties
-
Mathieu V, Vayron R, Richard G, Lambert G, Naili S, Meningaud JP, Haiat G (2014) Biomechanical determinants of the stability of dental implants: influence of the bone–implant interface properties. J Biomech 47:3–13
-
(2014)
J Biomech
, vol.47
, pp. 3-13
-
-
Mathieu, V.1
Vayron, R.2
Richard, G.3
Lambert, G.4
Naili, S.5
Meningaud, J.P.6
Haiat, G.7
-
29
-
-
84857795156
-
Influence of healing time on the ultrasonic response of the bone–implant interface
-
Mathieu V, Vayron R, Soffer E, Anagnostou F, Haiat G (2012) Influence of healing time on the ultrasonic response of the bone–implant interface. Ultrasound Med Biol 38:611–618
-
(2012)
Ultrasound Med Biol
, vol.38
, pp. 611-618
-
-
Mathieu, V.1
Vayron, R.2
Soffer, E.3
Anagnostou, F.4
Haiat, G.5
-
30
-
-
0030224153
-
Quantitative determination of the stability of the implant–tissue interface using resonance frequency analysis
-
Meredith N, Alleyne D, Cawley P (1996) Quantitative determination of the stability of the implant–tissue interface using resonance frequency analysis. Clin Oral Implant Res 7:261–267
-
(1996)
Clin Oral Implant Res
, vol.7
, pp. 261-267
-
-
Meredith, N.1
Alleyne, D.2
Cawley, P.3
-
31
-
-
0032059195
-
Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability
-
Meredith N, Friberg B, Sennerby L, Aparicio C (1998) Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability. Int J Prosthodont 11:269–275
-
(1998)
Int J Prosthodont
, vol.11
, pp. 269-275
-
-
Meredith, N.1
Friberg, B.2
Sennerby, L.3
Aparicio, C.4
-
32
-
-
0031152189
-
The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia
-
Meredith N, Shagaldi F, Alleyne D, Sennerby L, Cawley P (1997) The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Implant Res 8:234–243
-
(1997)
Clin Oral Implant Res
, vol.8
, pp. 234-243
-
-
Meredith, N.1
Shagaldi, F.2
Alleyne, D.3
Sennerby, L.4
Cawley, P.5
-
33
-
-
77954001731
-
Relationship between cortical bone thickness or computerized tomography-derived bone density values and implant stability
-
Merheb J, Van Assche N, Coucke W, Jacobs R, Naert I, Quirynen M (2010) Relationship between cortical bone thickness or computerized tomography-derived bone density values and implant stability. Clin Oral Implants Res 21:612–617
-
(2010)
Clin Oral Implants Res
, vol.21
, pp. 612-617
-
-
Merheb, J.1
Van Assche, N.2
Coucke, W.3
Jacobs, R.4
Naert, I.5
Quirynen, M.6
-
34
-
-
77954067429
-
Influence of viscoelastic and viscous absorption on ultrasonic wave propagation in cortical bone: application to axial transmission
-
Naili S, Vu MB, Grimal Q, Talmant M, Desceliers C, Soize C, Haiat G (2010) Influence of viscoelastic and viscous absorption on ultrasonic wave propagation in cortical bone: application to axial transmission. J Acoust Soc Am 127:2622–2628
-
(2010)
J Acoust Soc Am
, vol.127
, pp. 2622-2628
-
-
Naili, S.1
Vu, M.B.2
Grimal, Q.3
Talmant, M.4
Desceliers, C.5
Soize, C.6
Haiat, G.7
-
35
-
-
0033382521
-
An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen
-
Njeh CF, Hans D, Wu C, Kantorovich E, Sister M, Fuerst T, Genant HK (1999) An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen. Med Eng Phys 21:651–659
-
(1999)
Med Eng Phys
, vol.21
, pp. 651-659
-
-
Njeh, C.F.1
Hans, D.2
Wu, C.3
Kantorovich, E.4
Sister, M.5
Fuerst, T.6
Genant, H.K.7
-
36
-
-
0345304947
-
Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants
-
Nkenke E, Hahn M, Weinzierl K, Radespiel-Troger M, Neukam FW, Engelke K (2003) Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants. Clin Oral Implants Res 14:601–609
-
(2003)
Clin Oral Implants Res
, vol.14
, pp. 601-609
-
-
Nkenke, E.1
Hahn, M.2
Weinzierl, K.3
Radespiel-Troger, M.4
Neukam, F.W.5
Engelke, K.6
-
37
-
-
34250158575
-
Resonance frequency analysis of implants in the guinea pig model: influence of boundary conditions and orientation of the transducer
-
Pattijn V et al (2007) Resonance frequency analysis of implants in the guinea pig model: influence of boundary conditions and orientation of the transducer. Med Eng Phys 29:182–190
-
(2007)
Med Eng Phys
, vol.29
, pp. 182-190
-
-
Pattijn, V.1
-
38
-
-
32644436644
-
The resonance frequencies and mode shapes of dental implants: rigid body behaviour versus bending behaviour—a numerical approach
-
Pattijn V, Van Lierde C, Van der Perre G, Naert I, Sloten JV (2006) The resonance frequencies and mode shapes of dental implants: rigid body behaviour versus bending behaviour—a numerical approach. J Biomech 39:939–947
-
(2006)
J Biomech
, vol.39
, pp. 939-947
-
-
Pattijn, V.1
Van Lierde, C.2
Van der Perre, G.3
Naert, I.4
Sloten, J.V.5
-
39
-
-
34547700240
-
Clinical study on the primary stability of two dental implant systems with resonance frequency analysis
-
Rabel A, Kohler SG, Schmidt-Westhausen AM (2007) Clinical study on the primary stability of two dental implant systems with resonance frequency analysis. Clin Oral Invest 11:257–265
-
(2007)
Clin Oral Invest
, vol.11
, pp. 257-265
-
-
Rabel, A.1
Kohler, S.G.2
Schmidt-Westhausen, A.M.3
-
41
-
-
84858073092
-
Anatomical distribution of the degree of mineralization of bone tissue in human femoral neck: impact on biomechanical properties
-
Sansalone V, Bousson V, Naili S, Bergot C, Peyrin F, Laredo JD, Haiat G (2012) Anatomical distribution of the degree of mineralization of bone tissue in human femoral neck: impact on biomechanical properties. Bone 50:876–884
-
(2012)
Bone
, vol.50
, pp. 876-884
-
-
Sansalone, V.1
Bousson, V.2
Naili, S.3
Bergot, C.4
Peyrin, F.5
Laredo, J.D.6
Haiat, G.7
-
42
-
-
77954141832
-
Determination of the heterogeneous anisotropic elastic properties of human femoral bone: from nanoscopic to organ scale
-
Sansalone V et al (2010) Determination of the heterogeneous anisotropic elastic properties of human femoral bone: from nanoscopic to organ scale. J Biomech 43:1857–1863. doi:10.1016/j.jbiomech.2010.03.034
-
(2010)
J Biomech
, vol.43
, pp. 1857-1863
-
-
Sansalone, V.1
-
43
-
-
44949160979
-
Singular value decomposition-based wave extraction in axial transmission: application to cortical bone ultrasonic characterization
-
Sasso M, Haiat G, Talmant M, Laugier P, Naili S (2008a) Singular value decomposition-based wave extraction in axial transmission: application to cortical bone ultrasonic characterization. IEEE Trans Ultrason Ferroelectr Freq Control 55:1328–1332
-
(2008)
IEEE Trans Ultrason Ferroelectr Freq Control
, vol.55
, pp. 1328-1332
-
-
Sasso, M.1
Haiat, G.2
Talmant, M.3
Laugier, P.4
Naili, S.5
-
44
-
-
36849065176
-
Frequency dependence of ultrasonic attenuation in bovine cortical bone: an in vitro study
-
Sasso M, Haiat G, Yamato Y, Naili S, Matsukawa M (2007) Frequency dependence of ultrasonic attenuation in bovine cortical bone: an in vitro study. Ultrasound Med Biol 33:1933–1942
-
(2007)
Ultrasound Med Biol
, vol.33
, pp. 1933-1942
-
-
Sasso, M.1
Haiat, G.2
Yamato, Y.3
Naili, S.4
Matsukawa, M.5
-
45
-
-
38149065193
-
Dependence of ultrasonic attenuation to bone mass and microstructure in bovine cortical bone
-
Sasso M, Haiat G, Yamato Y, Naili S, Matsukawa M (2008b) Dependence of ultrasonic attenuation to bone mass and microstructure in bovine cortical bone. J Biomech 41:347–355
-
(2008)
J Biomech
, vol.41
, pp. 347-355
-
-
Sasso, M.1
Haiat, G.2
Yamato, Y.3
Naili, S.4
Matsukawa, M.5
-
46
-
-
0020768715
-
Periotest: a new measurement process for periodontal function
-
Schulte W et al (1983) Periotest: a new measurement process for periodontal function. Zahnarztl Mitt 73:1229–1230
-
(1983)
Zahnarztl Mitt
, vol.73
, pp. 1229-1230
-
-
Schulte, W.1
-
47
-
-
65349153816
-
Correlations between physical properties of jawbone and dental implant initial stability
-
Seong WJ, Kim UK, Swift JQ, Hodges JS, Ko CC (2009) Correlations between physical properties of jawbone and dental implant initial stability. J Prosthet Dent 101:306–318
-
(2009)
J Prosthet Dent
, vol.101
, pp. 306-318
-
-
Seong, W.J.1
Kim, U.K.2
Swift, J.Q.3
Hodges, J.S.4
Ko, C.C.5
-
48
-
-
46249123758
-
Sequential bone healing of immediately loaded mini-implants
-
Serra G, Morais LS, Elias CN, Meyers MA, Andrade L, Muller C, Muller M (2008) Sequential bone healing of immediately loaded mini-implants. Am J Orthod Dentofacial Orthop 134:44–52
-
(2008)
Am J Orthod Dentofacial Orthop
, vol.134
, pp. 44-52
-
-
Serra, G.1
Morais, L.S.2
Elias, C.N.3
Meyers, M.A.4
Andrade, L.5
Muller, C.6
Muller, M.7
-
49
-
-
34548681456
-
Evaluation of bone response to titanium-coated polymethyl methacrylate resin (PMMA) implants by X-ray tomography
-
Shalabi MM, Wolke JGC, Cuijpers V, Jansen JA (2007) Evaluation of bone response to titanium-coated polymethyl methacrylate resin (PMMA) implants by X-ray tomography. J Mater Sci Mater Med 18:2033–2039
-
(2007)
J Mater Sci Mater Med
, vol.18
, pp. 2033-2039
-
-
Shalabi, M.M.1
Wolke, J.G.C.2
Cuijpers, V.3
Jansen, J.A.4
-
50
-
-
84864684481
-
Advanced material modelling in numerical simulation of primary acetabular press-fit cup stability
-
Souffrant R, Zietz C, Fritsche A, Kluess D, Mittelmeier W, Bader R (2012) Advanced material modelling in numerical simulation of primary acetabular press-fit cup stability. Comput Methods Biomech Biomed Eng 15:787–793
-
(2012)
Comput Methods Biomech Biomed Eng
, vol.15
, pp. 787-793
-
-
Souffrant, R.1
Zietz, C.2
Fritsche, A.3
Kluess, D.4
Mittelmeier, W.5
Bader, R.6
-
51
-
-
55149116779
-
Two alternative surgical techniques for enhancing primary implant stability in the posterior Maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data
-
Turkyilmaz I, Aksoy U, McGlumphy EA (2008) Two alternative surgical techniques for enhancing primary implant stability in the posterior Maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data. Clin Implant Dent Rel Res 10:231–237
-
(2008)
Clin Implant Dent Rel Res
, vol.10
, pp. 231-237
-
-
Turkyilmaz, I.1
Aksoy, U.2
McGlumphy, E.A.3
-
52
-
-
33751351701
-
Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement
-
Turkyilmaz I, Tozum TF, Tumer C, Ozbek EN (2006) Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement. J Oral Rehabil 33:881–888
-
(2006)
J Oral Rehabil
, vol.33
, pp. 881-888
-
-
Turkyilmaz, I.1
Tozum, T.F.2
Tumer, C.3
Ozbek, E.N.4
-
53
-
-
34547174147
-
Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants
-
Turkyilmaz I, Tumer C, Ozbek EN, Tozum TF (2007) Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants. J Clin Periodontol 34:716–722
-
(2007)
J Clin Periodontol
, vol.34
, pp. 716-722
-
-
Turkyilmaz, I.1
Tumer, C.2
Ozbek, E.N.3
Tozum, T.F.4
-
54
-
-
33847790159
-
Evaluation of two different resonance frequency devices to detect implant stability: a clinical trial
-
Valderrama P, Oates TW, Jones AA, Simpson J, Schoolfield JD, Cochran D (2007) Evaluation of two different resonance frequency devices to detect implant stability: a clinical trial. J Periodont 78:262–272
-
(2007)
J Periodont
, vol.78
, pp. 262-272
-
-
Valderrama, P.1
Oates, T.W.2
Jones, A.A.3
Simpson, J.4
Schoolfield, J.D.5
Cochran, D.6
-
55
-
-
0026301746
-
The Periotest method for determining implant success
-
Van Scotter DE, Wilson CJ (1991) The Periotest method for determining implant success. J Oral Implantol 17:410–413
-
(1991)
J Oral Implantol
, vol.17
, pp. 410-413
-
-
Van Scotter, D.E.1
Wilson, C.J.2
-
56
-
-
84872922650
-
Variation of biomechanical properties of newly formed bone tissue determined by nanoindentation as a function of healing time
-
Vayron R, Barthel E, Mathieu V, Soffer E, Anagnostou F, Haiat G (2011) Variation of biomechanical properties of newly formed bone tissue determined by nanoindentation as a function of healing time. Comput Methods Biomech Biomed Eng 14:139–140
-
(2011)
Comput Methods Biomech Biomed Eng
, vol.14
, pp. 139-140
-
-
Vayron, R.1
Barthel, E.2
Mathieu, V.3
Soffer, E.4
Anagnostou, F.5
Haiat, G.6
-
57
-
-
84859911623
-
Nanoindentation measurements of biomechanical properties in mature and newly formed bone tissue surrounding an implant
-
Vayron R, Barthel E, Mathieu V, Soffer E, Anagnostou F, Haiat G (2012) Nanoindentation measurements of biomechanical properties in mature and newly formed bone tissue surrounding an implant. J Biomech Eng 134:021007
-
(2012)
J Biomech Eng
, vol.134
, pp. 021007
-
-
Vayron, R.1
Barthel, E.2
Mathieu, V.3
Soffer, E.4
Anagnostou, F.5
Haiat, G.6
-
58
-
-
84875375725
-
Variation of the ultrasonic response of a dental implant embedded in tricalcium silicate-based cement under cyclic loading
-
Vayron R et al (2013) Variation of the ultrasonic response of a dental implant embedded in tricalcium silicate-based cement under cyclic loading. J Biomech 46:1162–1168
-
(2013)
J Biomech
, vol.46
, pp. 1162-1168
-
-
Vayron, R.1
-
59
-
-
84896753999
-
Assessment of in vitro dental implant primary stability using an ultrasonic method
-
Vayron R, Mathieu V, Michel A, Haïat G (2014a) Assessment of in vitro dental implant primary stability using an ultrasonic method. Ultrasound Med Biol 40(12):2885–2894
-
(2014)
Ultrasound Med Biol
, vol.40
, Issue.12
, pp. 2885-2894
-
-
Vayron, R.1
Mathieu, V.2
Michel, A.3
Haïat, G.4
-
61
-
-
84896797044
-
Evolution of bone biomechanical properties at the micrometer scale around titanium implant as a function of healing time
-
Vayron R, Matsukawa M, Mathieu V, Barthel E, Soffer E, Anagnostou F, Haiat G (2014c) Evolution of bone biomechanical properties at the micrometer scale around titanium implant as a function of healing time. Phys Med Biol 59:1389–1406
-
(2014)
Phys Med Biol
, vol.59
, pp. 1389-1406
-
-
Vayron, R.1
Matsukawa, M.2
Mathieu, V.3
Barthel, E.4
Soffer, E.5
Anagnostou, F.6
Haiat, G.7
-
62
-
-
33748263834
-
Primary stability of an anatomical cementless hip stem: a statistical analysis
-
Viceconti M, Brusi G, Pancanti A, Cristofolini L (2006) Primary stability of an anatomical cementless hip stem: a statistical analysis. J Biomech 39:1169–1179. doi:10.1016/j.jbiomech.2005.03.024
-
(2006)
J Biomech
, vol.39
, pp. 1169-1179
-
-
Viceconti, M.1
Brusi, G.2
Pancanti, A.3
Cristofolini, L.4
-
63
-
-
0034761815
-
Even a thin layer of soft tissue may compromise the primary stability of cementless hip stems
-
Viceconti M, Monti L, Muccini R, Bernakiewicz M, Toni A (2001) Even a thin layer of soft tissue may compromise the primary stability of cementless hip stems. Clin Biomech 16:765–775
-
(2001)
Clin Biomech
, vol.16
, pp. 765-775
-
-
Viceconti, M.1
Monti, L.2
Muccini, R.3
Bernakiewicz, M.4
Toni, A.5
-
64
-
-
77954973261
-
Bone–cement interfacial behaviour under mixed mode loading conditions
-
Wang JY, Tozzi G, Chen J, Contal F, Lupton C, Tong J (2010a) Bone–cement interfacial behaviour under mixed mode loading conditions. J Mech Behav Biomed Mater 3:392–398
-
(2010)
J Mech Behav Biomed Mater
, vol.3
, pp. 392-398
-
-
Wang, J.Y.1
Tozzi, G.2
Chen, J.3
Contal, F.4
Lupton, C.5
Tong, J.6
-
65
-
-
73049090096
-
Pullout strength of miniscrews placed in anterior mandibles of adult and adolescent dogs: a microcomputed tomographic analysis
-
Wang ZQ, Zhao ZH, Xue J, Song JL, Deng F, Yang P (2010b) Pullout strength of miniscrews placed in anterior mandibles of adult and adolescent dogs: a microcomputed tomographic analysis. Am J Orthod Dentofac Orthop 137:100–107
-
(2010)
Am J Orthod Dentofac Orthop
, vol.137
, pp. 100-107
-
-
Wang, Z.Q.1
Zhao, Z.H.2
Xue, J.3
Song, J.L.4
Deng, F.5
Yang, P.6
-
66
-
-
77955909209
-
Parameters of implant stability measurements based on resonance frequency and damping capacity: a comparative finite element analysis
-
Winter W, Mohrle S, Holst S, Karl M (2010) Parameters of implant stability measurements based on resonance frequency and damping capacity: a comparative finite element analysis. Int J Oral Maxillofac Implants 25:532–539
-
(2010)
Int J Oral Maxillofac Implants
, vol.25
, pp. 532-539
-
-
Winter, W.1
Mohrle, S.2
Holst, S.3
Karl, M.4
-
67
-
-
67650168952
-
Orthodontic mini-implant stability in different healing times before loading: a microscopic computerized tomographic and biomechanical analysis
-
Zhao LX, Xu ZR, Yang Z, Wei X, Tang T, Zhao ZH (2009) Orthodontic mini-implant stability in different healing times before loading: a microscopic computerized tomographic and biomechanical analysis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 108:196–202
-
(2009)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.108
, pp. 196-202
-
-
Zhao, L.X.1
Xu, Z.R.2
Yang, Z.3
Wei, X.4
Tang, T.5
Zhao, Z.H.6
|