메뉴 건너뛰기




Volumn 12, Issue 6, 2016, Pages 348-359

Radiologic imaging of the renal parenchyma structure and function

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC RADIATION FORCE IMPULSE IMAGING; ANISOTROPY; BOLD SIGNAL; CARBON NUCLEAR MAGNETIC RESONANCE; CELL THERAPY; COMPUTER ASSISTED TOMOGRAPHY; CONTRAST INDUCED NEPHROPATHY; DIABETIC NEPHROPATHY; DIFFUSION TENSOR IMAGING; DIFFUSION WEIGHTED IMAGING; DOPPLER ULTRASONOGRAPHY; ECHOGRAPHY; ELASTOGRAPHY; FLUORINE NUCLEAR MAGNETIC RESONANCE; GLOMERULUS FILTRATION; GLOMERULUS FILTRATION RATE; HUMAN; KIDNEY BLOOD FLOW; KIDNEY CIRCULATION; KIDNEY CYST; KIDNEY FUNCTION; KIDNEY METABOLISM; KIDNEY PARENCHYMA; KIDNEY POLYCYSTIC DISEASE; KIDNEY STRUCTURE; KIDNEY TUBULE ABSORPTION; NEPHRITIS; NITROGEN NUCLEAR MAGNETIC RESONANCE; NONHUMAN; OXYGENATION; PH; PHAGOCYTOSIS; PHOSPHORUS NUCLEAR MAGNETIC RESONANCE; PRIORITY JOURNAL; PROTON NUCLEAR MAGNETIC RESONANCE; RENOGRAPHY; REVIEW; TISSUE PERFUSION; VASCULAR RESISTANCE; X IRRADIATION; ANATOMY AND HISTOLOGY; ANIMAL; DIAGNOSTIC IMAGING; KIDNEY; KIDNEY DISEASE; METABOLISM; NUCLEAR MAGNETIC RESONANCE IMAGING; PARENCHYMA; PATHOLOGY; PATHOPHYSIOLOGY; X-RAY COMPUTED TOMOGRAPHY;

EID: 84963615026     PISSN: 17595061     EISSN: 1759507X     Source Type: Journal    
DOI: 10.1038/nrneph.2016.44     Document Type: Review
Times cited : (72)

References (121)
  • 2
    • 79953013835 scopus 로고    scopus 로고
    • Diffusion-weighted MR imaging of native and transplanted kidneys
    • Thoeny H. C., & De Keyzer F. Diffusion-weighted MR imaging of native and transplanted kidneys. Radiology 259, 25-38 (2011
    • (2011) Radiology , vol.259 , pp. 25-38
    • Thoeny, H.C.1    De Keyzer, F.2
  • 3
    • 84941952143 scopus 로고    scopus 로고
    • Revisiting the risks of MRI with gadolinium based contrast agents - Review of literature and guidelines
    • Khawaja A. Z., et al. Revisiting the risks of MRI with Gadolinium based contrast agents - review of literature and guidelines. Insights Imaging 6, 553-558 (2015
    • (2015) Insights Imaging , vol.6 , pp. 553-558
    • Khawaja, A.Z.1
  • 4
    • 84896947165 scopus 로고    scopus 로고
    • Risk of intravenous contrast material-mediated acute kidney injury: A propensity score-matched study stratified by baseline-estimated glomerular filtration rate
    • McDonald J. S., et al. Risk of intravenous contrast material-mediated acute kidney injury: a propensity score-matched study stratified by baseline-estimated glomerular filtration rate. Radiology 271, 65-73 (2014
    • (2014) Radiology , vol.271 , pp. 65-73
    • McDonald, J.S.1
  • 5
    • 6344229756 scopus 로고    scopus 로고
    • Ultrasound measured renal length versus low dose CT volume in predicting single kidney glomerular filtration rate
    • Widjaja E., et al. Ultrasound measured renal length versus low dose CT volume in predicting single kidney glomerular filtration rate. Br. J. Radiol. 77, 759-764 (2004
    • (2004) Br. J. Radiol , vol.77 , pp. 759-764
    • Widjaja, E.1
  • 6
    • 20744442718 scopus 로고    scopus 로고
    • Functional renal volume: Quantitative analysis at gadolinium-enhanced MR angiography - Feasibility study in healthy potential kidney donors
    • van Den Dool S. W., Wasser M. N., de Fijter J. W., Hoekstra J., & van Der Geest R. J. Functional renal volume: quantitative analysis at gadolinium-enhanced MR angiography - feasibility study in healthy potential kidney donors. Radiology 236, 189-195 (2005
    • (2005) Radiology , vol.236 , pp. 189-195
    • Van Den Dool, S.W.1    Wasser, M.N.2    De Fijter, J.W.3    Hoekstra, J.4    Van Der Geest, R.J.5
  • 7
    • 0036154129 scopus 로고    scopus 로고
    • Measurement of renal volumes with contrast-enhanced MRI
    • Coulam C. H., Bouley D. M., & Sommer F. G. Measurement of renal volumes with contrast-enhanced MRI. J. Magn. Reson. Imaging 15, 174-179 (2002
    • (2002) J. Magn. Reson. Imaging , vol.15 , pp. 174-179
    • Coulam, C.H.1    Bouley, D.M.2    Sommer, F.G.3
  • 8
    • 77949535509 scopus 로고    scopus 로고
    • Large kidneys predict poor renal outcome in subjects with diabetes and chronic kidney disease
    • Rigalleau V., et al. Large kidneys predict poor renal outcome in subjects with diabetes and chronic kidney disease. BMC Nephrol. 11, 3 (2010
    • (2010) BMC Nephrol , vol.11 , pp. 3
    • Rigalleau, V.1
  • 9
    • 51349164454 scopus 로고    scopus 로고
    • In vitro assessment of a 3D segmentation algorithm based on the belief functions theory in calculating renal volumes by MRI
    • Vivier P. H., et al. In vitro assessment of a 3D segmentation algorithm based on the belief functions theory in calculating renal volumes by MRI. AJR Am. J. Roentgenol. 191, W127-W134 (2008
    • (2008) AJR Am. J. Roentgenol , vol.191 , pp. W127-W134
    • Vivier, P.H.1
  • 10
    • 32544435479 scopus 로고    scopus 로고
    • MR derived renal morphology and renal function in patients with atherosclerotic renovascular disease
    • Cheung C. M., et al. MR derived renal morphology and renal function in patients with atherosclerotic renovascular disease. Kidney Int. 69, 715-722 (2006
    • (2006) Kidney Int , vol.69 , pp. 715-722
    • Cheung, C.M.1
  • 11
    • 0028047649 scopus 로고
    • Renal corticomedullary differentiation: Observation in patients with differing serum creatinine levels
    • Semelka R. C., et al. Renal corticomedullary differentiation: observation in patients with differing serum creatinine levels. Radiology 190, 149-152 (1994
    • (1994) Radiology , vol.190 , pp. 149-152
    • Semelka, R.C.1
  • 12
    • 0034848049 scopus 로고    scopus 로고
    • Acute renal failure: Common occurrence of preservation of corticomedullary differentiation on MR images
    • Chung J. J., Semelka R. C., & Martin D. R. Acute renal failure: common occurrence of preservation of corticomedullary differentiation on MR images. Magn. Reson. Imaging 19, 789-793 (2001
    • (2001) Magn. Reson. Imaging , vol.19 , pp. 789-793
    • Chung, J.J.1    Semelka, R.C.2    Martin, D.R.3
  • 14
    • 0036654024 scopus 로고    scopus 로고
    • Atypical low-signal-intensity renal parenchyma: Causes and patterns
    • Jeong J. Y., Kim S. H., Lee H. J., & Sim J. S. Atypical low-signal-intensity renal parenchyma: causes and patterns. Radiographics 22, 833-846 (2002
    • (2002) Radiographics , vol.22 , pp. 833-846
    • Jeong, J.Y.1    Kim, S.H.2    Lee, H.J.3    Sim, J.S.4
  • 15
    • 12444274302 scopus 로고    scopus 로고
    • Renal structure in early autosomal-dominant polycystic kidney disease (adpkd): The consortium for radiologic imaging studies of polycystic kidney disease (crisp) cohort
    • Chapman A. B., et al. Renal structure in early autosomal-dominant polycystic kidney disease (ADPKD): the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease (CRISP) cohort. Kidney Int. 64, 1035-1045 (2003
    • (2003) Kidney Int , vol.64 , pp. 1035-1045
    • Chapman, A.B.1
  • 16
    • 66449117932 scopus 로고    scopus 로고
    • MRI-based kidney volume measurements in ADPKD: Reliability and effect of gadolinium enhancement
    • Bae K. T., et al. MRI-based kidney volume measurements in ADPKD: reliability and effect of gadolinium enhancement. Clin. J. Am. Soc. Nephrol. 4, 719-725 (2009
    • (2009) Clin. J. Am. Soc. Nephrol , vol.4 , pp. 719-725
    • Bae, K.T.1
  • 17
    • 33646678189 scopus 로고    scopus 로고
    • Volume progression in polycystic kidney disease
    • Grantham J. J., et al. Volume progression in polycystic kidney disease. N. Engl. J. Med. 354, 2122-2130 (2006
    • (2006) N. Engl. J. Med , vol.354 , pp. 2122-2130
    • Grantham, J.J.1
  • 18
    • 84871303897 scopus 로고    scopus 로고
    • Tolvaptan in patients with autosomal dominant polycystic kidney disease
    • Torres V. E., et al. Tolvaptan in patients with autosomal dominant polycystic kidney disease. N. Engl. J. Med. 367, 2407-2418 (2012
    • (2012) N. Engl. J. Med , vol.367 , pp. 2407-2418
    • Torres, V.E.1
  • 19
    • 84911960390 scopus 로고    scopus 로고
    • An approach to cystic kidney diseases: The clinician's view
    • Kurschat C. E., et al. An approach to cystic kidney diseases: the clinician's view. Nat. Rev. Nephrol. 10, 687-699 (2014
    • (2014) Nat. Rev. Nephrol , vol.10 , pp. 687-699
    • Kurschat, C.E.1
  • 20
    • 33751410697 scopus 로고    scopus 로고
    • Recent advances in iron oxide nanocrystal technology for medical imaging
    • Corot C., Robert P., Idée J. M., & Port M. Recent advances in iron oxide nanocrystal technology for medical imaging. Adv. Drug Deliv. Rev. 1, 1471-1504 (2006
    • (2006) Adv. Drug Deliv. Rev , vol.1 , pp. 1471-1504
    • Corot, C.1    Robert, P.2    Idée, J.M.3    Port, M.4
  • 21
    • 0033708671 scopus 로고    scopus 로고
    • Nephrotoxic nephritis and obstructive nephropathy: Evaluation with MR imaging enhanced with ultrasmall superparamagnetic iron oxide-preliminary findings in a rat model
    • Hauger O., et al. Nephrotoxic nephritis and obstructive nephropathy: evaluation with MR imaging enhanced with ultrasmall superparamagnetic iron oxide-preliminary findings in a rat model. Radiology 217, 819-826 (2000
    • (2000) Radiology , vol.217 , pp. 819-826
    • Hauger, O.1
  • 22
    • 0036183760 scopus 로고    scopus 로고
    • In vivo detection of acute rat renal allograft rejection by mri with uspio particles
    • Ye Q., et al. In vivo detection of acute rat renal allograft rejection by MRI with USPIO particles. Kidney Int. 61, 1124-1135 (2002
    • (2002) Kidney Int , vol.61 , pp. 1124-1135
    • Ye, Q.1
  • 23
    • 0038130713 scopus 로고    scopus 로고
    • Detection of inflammation following renal ischemia by magnetic resonance imaging
    • Jo S. K., et al. Detection of inflammation following renal ischemia by magnetic resonance imaging. Kidney Int. 64, 43-51 (2003
    • (2003) Kidney Int , vol.64 , pp. 43-51
    • Jo, S.K.1
  • 24
    • 33747606751 scopus 로고    scopus 로고
    • Macrophage infiltration detected at MR imaging in rat kidney allografts: Early marker of chronic rejection?
    • Beckmann N., et al. Macrophage infiltration detected at MR imaging in rat kidney allografts: early marker of chronic rejection?. Radiology 240, 717-724 (2006
    • (2006) Radiology , vol.240 , pp. 717-724
    • Beckmann, N.1
  • 25
    • 35349021658 scopus 로고    scopus 로고
    • USPIO-enhanced MR imaging of macrophage infiltration in native and transplanted kidneys: Initial results in humans
    • Hauger O., et al. USPIO-enhanced MR imaging of macrophage infiltration in native and transplanted kidneys: initial results in humans. Eur. Radiol. 17, 2898-2907 (2007
    • (2007) Eur. Radiol , vol.17 , pp. 2898-2907
    • Hauger, O.1
  • 26
    • 84899766564 scopus 로고    scopus 로고
    • Evaluation of renal quantitative T2∗ changes on MRI following administration of ferumoxytol as a T2∗ contrast agent
    • Hedgire S. S., et al. Evaluation of renal quantitative T2∗ changes on MRI following administration of ferumoxytol as a T2∗ contrast agent. Int. J. Nanomedicine 9, 2101-2107 (2014
    • (2014) Int. J. Nanomedicine , vol.9 , pp. 2101-2107
    • Hedgire, S.S.1
  • 27
    • 77956116300 scopus 로고    scopus 로고
    • Allogeneic renal graft rejection in a rat model: In vivo MR imaging of the homing trait of macrophages
    • Chae E. Y., et al. Allogeneic renal graft rejection in a rat model: in vivo MR imaging of the homing trait of macrophages. Radiology 256, 847-854 (2010
    • (2010) Radiology , vol.256 , pp. 847-854
    • Chae, E.Y.1
  • 28
    • 84855171565 scopus 로고    scopus 로고
    • Detection of glomerular complement C3 fragments by magnetic resonance imaging in murine lupus nephritis
    • Sargsyan S. A., et al. Detection of glomerular complement C3 fragments by magnetic resonance imaging in murine lupus nephritis. Kidney Int. 81, 152-159 (2012
    • (2012) Kidney Int , vol.81 , pp. 152-159
    • Sargsyan, S.A.1
  • 29
    • 77951489842 scopus 로고    scopus 로고
    • Renal inflammation: Targeted iron oxide nanoparticles for molecular MR imaging in mice
    • Serkova N. J., et al. Renal inflammation: targeted iron oxide nanoparticles for molecular MR imaging in mice. Radiology 255, 517-526 (2010
    • (2010) Radiology , vol.255 , pp. 517-526
    • Serkova, N.J.1
  • 30
    • 84958102067 scopus 로고    scopus 로고
    • Noninvasive imaging of acute renal allograft rejection by ultrasound detection of microbubbles targeted to T lymphocytes in rats
    • Grabner A., et al. Noninvasive imaging of acute renal allograft rejection by ultrasound detection of microbubbles targeted to T lymphocytes in rats. Ultraschall Med. 37, 82-91 (2016
    • (2016) Ultraschall Med , vol.37 , pp. 82-91
    • Grabner, A.1
  • 31
    • 16244375854 scopus 로고    scopus 로고
    • Correlation of renal histopathology with sonographic findings
    • Moghazi S., et al. Correlation of renal histopathology with sonographic findings. Kidney Int. 67, 1515-1520 (2005
    • (2005) Kidney Int , vol.67 , pp. 1515-1520
    • Moghazi, S.1
  • 32
    • 84942279339 scopus 로고    scopus 로고
    • Is increased echogenicity related to a decrease in glomerular filtration rate?. Objective measurements in pediatric solitary kidney patients - A retrospective analysis
    • Lee V. S., et al. Is increased echogenicity related to a decrease in glomerular filtration rate?. Objective measurements in pediatric solitary kidney patients - a retrospective analysis. PLoS ONE 10, e0133577 (2015
    • (2015) Plos One , vol.10 , pp. e0133577
    • Lee, V.S.1
  • 33
    • 0037219787 scopus 로고    scopus 로고
    • Renal diffusion and bold mri in experimental diabetic nephropathy
    • Ries M., et al. Renal diffusion and BOLD MRI in experimental diabetic nephropathy. J. Magn. Reson. Imaging 17, 104-113 (2003
    • (2003) J. Magn. Reson. Imaging , vol.17 , pp. 104-113
    • Ries, M.1
  • 34
    • 18844398665 scopus 로고    scopus 로고
    • Diffusion-weighted MR imaging of kidneys in healthy volunteers and patients with parenchymal diseases: Initial experience
    • Thoeny H. C., De Keyzer F., Oyen R. H., & Peeters R. R. Diffusion-weighted MR imaging of kidneys in healthy volunteers and patients with parenchymal diseases: initial experience. Radiology 235, 911-917 (2005
    • (2005) Radiology , vol.235 , pp. 911-917
    • Thoeny, H.C.1    De Keyzer, F.2    Oyen, R.H.3    Peeters, R.R.4
  • 35
    • 35248826477 scopus 로고    scopus 로고
    • Relationship between the renal apparent diffusion coefficient and glomerular filtration rate: Preliminary experience
    • Xu Y., Wang X., & Jiang X. Relationship between the renal apparent diffusion coefficient and glomerular filtration rate: preliminary experience. J. Magn. Reson. Imaging 26, 678-681 (2007
    • (2007) J. Magn. Reson. Imaging , vol.26 , pp. 678-681
    • Xu, Y.1    Wang, X.2    Jiang, X.3
  • 36
    • 77952677186 scopus 로고    scopus 로고
    • Assessment of renal fibrosis with diffusion-weighted MR imaging: Study with murine model of unilateral ureteral obstruction
    • Togao O., et al. Assessment of renal fibrosis with diffusion-weighted MR imaging: study with murine model of unilateral ureteral obstruction. Radiology 255, 772-780 (2010
    • (2010) Radiology , vol.255 , pp. 772-780
    • Togao, O.1
  • 39
    • 84905580667 scopus 로고    scopus 로고
    • Real-time elastography in the assessment of liver fibrosis: A review of qualitative and semi-quantitative methods for elastogram analysis
    • Paparo F., et al. Real-time elastography in the assessment of liver fibrosis: a review of qualitative and semi-quantitative methods for elastogram analysis. Ultrasound Med. Biol. 40, 1923-1933 (2014
    • (2014) Ultrasound Med. Biol , vol.40 , pp. 1923-1933
    • Paparo, F.1
  • 40
    • 84881660344 scopus 로고    scopus 로고
    • Renal transplant elasticity ultrasound imaging: Correlation between normalized strain and renal cortical fibrosis
    • Gao J., et al. Renal transplant elasticity ultrasound imaging: correlation between normalized strain and renal cortical fibrosis. Ultrasound Med. Biol. 39, 1536-1542 (2013
    • (2013) Ultrasound Med. Biol , vol.39 , pp. 1536-1542
    • Gao, J.1
  • 41
    • 84907984022 scopus 로고    scopus 로고
    • Kidney transplant: Usefulness of real-time elastography (RTE) in the diagnosis of graft interstitial fibrosis
    • Orlacchio A., et al. Kidney transplant: usefulness of real-time elastography (RTE) in the diagnosis of graft interstitial fibrosis. Ultrasound Med. Biol. 40, 2564-2572 (2014
    • (2014) Ultrasound Med. Biol , vol.40 , pp. 2564-2572
    • Orlacchio, A.1
  • 42
    • 84864601180 scopus 로고    scopus 로고
    • Supersonic shear wave elastography of in vivo pig kidney: Influence of blood pressure, urinary pressure and tissue anisotropy
    • Gennisson J. L., Grenier N., Combe C., & Tanter M. Supersonic shear wave elastography of in vivo pig kidney: influence of blood pressure, urinary pressure and tissue anisotropy. Ultrasound Med. Biol. 38, 1559-1567 (2012
    • (2012) Ultrasound Med. Biol , vol.38 , pp. 1559-1567
    • Gennisson, J.L.1    Grenier, N.2    Combe, C.3    Tanter, M.4
  • 44
    • 84867241145 scopus 로고    scopus 로고
    • Tissue elasticity estimated by acoustic radiation force impulse quantification depends on the applied transducer force: An experimental study in kidney transplant patients
    • Syversveen T., et al. Tissue elasticity estimated by acoustic radiation force impulse quantification depends on the applied transducer force: an experimental study in kidney transplant patients. Eur. Radiol. 22, 2130-2137 (2012
    • (2012) Eur. Radiol , vol.22 , pp. 2130-2137
    • Syversveen, T.1
  • 45
    • 84899488445 scopus 로고    scopus 로고
    • Acoustic radiation force impulse elastography of the kidneys: Is shear wave velocity affected by tissue fibrosis or renal blood flow?
    • Asano K., et al. Acoustic radiation force impulse elastography of the kidneys: is shear wave velocity affected by tissue fibrosis or renal blood flow?. J. Ultrasound Med. 33, 793-801 (2014
    • (2014) J. Ultrasound Med , vol.33 , pp. 793-801
    • Asano, K.1
  • 46
    • 84880056525 scopus 로고    scopus 로고
    • Acoustic radiation force impulse imaging for noninvasive evaluation of renal parenchyma elasticity: Preliminary findings
    • Guo L. H., et al. Acoustic radiation force impulse imaging for noninvasive evaluation of renal parenchyma elasticity: preliminary findings. PLoS ONE 8, e68925-e68928 (2013
    • (2013) Plos One , vol.8 , pp. e68925-e68928
    • Guo, L.H.1
  • 47
    • 84899488198 scopus 로고    scopus 로고
    • Value of virtual touch tissue quantification in stages of diabetic kidney disease
    • Yu N., Zhang Y., & Xu Y. Value of virtual touch tissue quantification in stages of diabetic kidney disease. J. Ultrasound Med. 33, 787-792 (2014
    • (2014) J. Ultrasound Med , vol.33 , pp. 787-792
    • Yu, N.1    Zhang, Y.2    Xu, Y.3
  • 48
    • 84928530475 scopus 로고    scopus 로고
    • Acoustic radiation force impulse imaging for evaluation of renal parenchyma elasticity in diabetic nephropathy
    • Goya C., et al. Acoustic radiation force impulse imaging for evaluation of renal parenchyma elasticity in diabetic nephropathy. AJR Am. J. Roentgenol. 204, 324-329 (2015
    • (2015) AJR Am. J. Roentgenol , vol.204 , pp. 324-329
    • Goya, C.1
  • 49
    • 84867247718 scopus 로고    scopus 로고
    • Quantitative elastography of renal transplants using supersonic shear imaging: A pilot study
    • Grenier N., et al. Quantitative elastography of renal transplants using supersonic shear imaging: a pilot study. Eur. Radiol. 22, 2138-2146 (2012
    • (2012) Eur. Radiol , vol.22 , pp. 2138-2146
    • Grenier, N.1
  • 50
    • 84862493994 scopus 로고    scopus 로고
    • MR elastography in renal transplant patients and correlation with renal allograft biopsy: A feasibility study
    • Lee C. U., et al. MR elastography in renal transplant patients and correlation with renal allograft biopsy: a feasibility study. Acad. Radiol. 19, 834-841 (2012
    • (2012) Acad. Radiol , vol.19 , pp. 834-841
    • Lee, C.U.1
  • 51
    • 53249109330 scopus 로고    scopus 로고
    • Predicting differential renal function using computerized tomography measurements of renal parenchymal area
    • Feder M. T., Blitstein J., Mason B., & Hoenig D. M. Predicting differential renal function using computerized tomography measurements of renal parenchymal area. J. Urol. 180, 2110-2115 (2008
    • (2008) J. Urol , vol.180 , pp. 2110-2115
    • Feder, M.T.1    Blitstein, J.2    Mason, B.3    Hoenig, D.M.4
  • 52
    • 84929431568 scopus 로고    scopus 로고
    • Utilizing magnetization transfer imaging to investigate tissue remodeling in a murine model of autosomal dominant polycystic kidney disease
    • Kline T. L., et al. Utilizing magnetization transfer imaging to investigate tissue remodeling in a murine model of autosomal dominant polycystic kidney disease. Magn. Reson. Med. 75, 1466-1473 (2015
    • (2015) Magn. Reson. Med , vol.75 , pp. 1466-1473
    • Kline, T.L.1
  • 53
    • 36049001771 scopus 로고    scopus 로고
    • Collagen-targeted MRI contrast agent for molecular imaging of fibrosis
    • Caravan P., et al. Collagen-targeted MRI contrast agent for molecular imaging of fibrosis. Angew. Chem. Int. Ed. Engl. 46, 8171-8173 (2007
    • (2007) Angew. Chem. Int. Ed. Engl , vol.46 , pp. 8171-8173
    • Caravan, P.1
  • 54
    • 84878776496 scopus 로고    scopus 로고
    • Human non-contrast T1 values and correlation with histology in diffuse fibrosis
    • Bull S., et al. Human non-contrast T1 values and correlation with histology in diffuse fibrosis. Heart 99, 932-937 (2013
    • (2013) Heart , vol.99 , pp. 932-937
    • Bull, S.1
  • 55
    • 84906101274 scopus 로고    scopus 로고
    • T1 mapping for assessment of ischemia-induced acute kidney injury and prediction of chronic kidney disease in mice
    • Hueper K., et al. T1 mapping for assessment of ischemia-induced acute kidney injury and prediction of chronic kidney disease in mice. Eur. Radiol. 24, 2252-2260 (2014
    • (2014) Eur. Radiol , vol.24 , pp. 2252-2260
    • Hueper, K.1
  • 56
    • 84921843936 scopus 로고    scopus 로고
    • Longitudinal assessment of mouse renal injury using high-resolution anatomic and magnetization transfer MR imaging
    • Wang F., et al. Longitudinal assessment of mouse renal injury using high-resolution anatomic and magnetization transfer MR imaging. Magn. Reson. Imaging 32, 1125-1132 (2014
    • (2014) Magn. Reson. Imaging , vol.32 , pp. 1125-1132
    • Wang, F.1
  • 57
    • 84880325455 scopus 로고    scopus 로고
    • Magnetisation transfer MR imaging of the kidney: Evaluation at 3.0 T in association with renal function
    • Ito K., et al. Magnetisation transfer MR imaging of the kidney: evaluation at 3.0 T in association with renal function. Eur. Radiol. 23, 2315-2319 (2013
    • (2013) Eur. Radiol , vol.23 , pp. 2315-2319
    • Ito, K.1
  • 58
    • 84890039561 scopus 로고    scopus 로고
    • Renal lipids and oxygenation in diabetic mice: Noninvasive quantification with MR imaging
    • Peng X. G., et al. Renal lipids and oxygenation in diabetic mice: noninvasive quantification with MR imaging. Radiology 269, 748-757 (2013
    • (2013) Radiology , vol.269 , pp. 748-757
    • Peng, X.G.1
  • 59
    • 84868706871 scopus 로고    scopus 로고
    • Kidney protection and regeneration following acute injury: Progress through stem cell therapy
    • Tögel F. E., & Westenfelder C. Kidney protection and regeneration following acute injury: progress through stem cell therapy. Am. J. Kidney Dis. 60, 1012-1022 (2012
    • (2012) Am. J. Kidney Dis , vol.60 , pp. 1012-1022
    • Tögel, F.E.1    Westenfelder, C.2
  • 60
    • 84948086347 scopus 로고    scopus 로고
    • Therapeutic use of human renal progenitor cells for kidney regeneration
    • Bussolati B., & Camussi G. Therapeutic use of human renal progenitor cells for kidney regeneration. Nat. Rev. Nephrol. 11, 695-706 (2015
    • (2015) Nat. Rev. Nephrol , vol.11 , pp. 695-706
    • Bussolati, B.1    Camussi, G.2
  • 61
    • 16544365679 scopus 로고    scopus 로고
    • In vivo MR imaging of intravascularly injected magnetically labeled mesenchymal stem cells in rat kidney and liver
    • Bos C., et al. In vivo MR imaging of intravascularly injected magnetically labeled mesenchymal stem cells in rat kidney and liver. Radiology 233, 781-789 (2004
    • (2004) Radiology , vol.233 , pp. 781-789
    • Bos, C.1
  • 62
    • 34249869807 scopus 로고    scopus 로고
    • In vivo magnetic resonance imaging of iron oxide-labeled, arterially-injected mesenchymal stem cells in kidneys of rats with acute ischemic kidney injury: Detection and monitoring at 3T
    • Ittrich H., et al. In vivo magnetic resonance imaging of iron oxide-labeled, arterially-injected mesenchymal stem cells in kidneys of rats with acute ischemic kidney injury: detection and monitoring at 3T. J. Magn. Reson. Imaging 25, 1179-1191 (2007
    • (2007) J. Magn. Reson. Imaging , vol.25 , pp. 1179-1191
    • Ittrich, H.1
  • 63
    • 29444442414 scopus 로고    scopus 로고
    • MR evaluation of the glomerular homing of magnetically labeled mesenchymal stem cells in a rat model of nephropathy
    • Hauger O., et al. MR evaluation of the glomerular homing of magnetically labeled mesenchymal stem cells in a rat model of nephropathy. Radiology 238, 200-210 (2006
    • (2006) Radiology , vol.238 , pp. 200-210
    • Hauger, O.1
  • 64
    • 34047273663 scopus 로고    scopus 로고
    • Magnetic resonance measurements of renal blood flow and disease progression in autosomal dominant polycystic kidney disease
    • Torres V. E., et al. Magnetic resonance measurements of renal blood flow and disease progression in autosomal dominant polycystic kidney disease. Clin. J. Am. Soc. Nephrol. 2, 112-120 (2007
    • (2007) Clin. J. Am. Soc. Nephrol , vol.2 , pp. 112-120
    • Torres, V.E.1
  • 65
    • 0036137599 scopus 로고    scopus 로고
    • Morphologic and functional magnetic resonance imaging of renal artery stenosis: A multireader tricenter study
    • Schoenberg S. O., et al. Morphologic and functional magnetic resonance imaging of renal artery stenosis: a multireader tricenter study. J. Am. Soc. Nephrol. 13, 158-169 (2002
    • (2002) J. Am. Soc. Nephrol , vol.13 , pp. 158-169
    • Schoenberg, S.O.1
  • 66
    • 84893171318 scopus 로고    scopus 로고
    • Inter-study reproducibility of arterial spin labelling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla
    • Gillis K. A., et al. Inter-study reproducibility of arterial spin labelling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla. BMC Nephrol. 15, 23 (2014
    • (2014) BMC Nephrol , vol.15 , pp. 23
    • Gillis, K.A.1
  • 67
    • 84944243041 scopus 로고    scopus 로고
    • Diagnostic value of quantitative contrast-enhanced ultrasound (ceus) for early detection of renal hyperperfusion in diabetic kidney disease
    • Wang L., et al. Diagnostic value of quantitative contrast-enhanced ultrasound (CEUS) for early detection of renal hyperperfusion in diabetic kidney disease. J. Nephrol. 28, 669-678 (2015
    • (2015) J. Nephrol , vol.28 , pp. 669-678
    • Wang, L.1
  • 68
    • 84857062533 scopus 로고    scopus 로고
    • The efsumb guidelines and recommendations on the clinical practice of contrast enhanced ultrasound (ceus): Update 2011 on non-hepatic applications
    • Piscaglia F., et al. The EFSUMB guidelines and recommendations on the clinical practice of contrast enhanced ultrasound (CEUS): update 2011 on non-hepatic applications. Ultraschall Med. 33, 33-59 (2012
    • (2012) Ultraschall Med , vol.33 , pp. 33-59
    • Piscaglia, F.1
  • 69
    • 79960680418 scopus 로고    scopus 로고
    • Renal perfusion: Noninvasive measurement with multidetector CT versus fluorescent microspheres in a pig model
    • Lemoine S., et al. Renal perfusion: noninvasive measurement with multidetector CT versus fluorescent microspheres in a pig model. Radiology 260, 414-420 (2011
    • (2011) Radiology , vol.260 , pp. 414-420
    • Lemoine, S.1
  • 72
    • 77953618442 scopus 로고    scopus 로고
    • Compartmental modelling for magnetic resonance renography
    • Sourbron S. Compartmental modelling for magnetic resonance renography. Z. Med. Phys. 20, 101-114 (2010
    • (2010) Z. Med. Phys , vol.20 , pp. 101-114
    • Sourbron, S.1
  • 73
    • 60549094053 scopus 로고    scopus 로고
    • Estimates of glomerular filtration rate from MR renography and tracer kinetic models
    • Bokacheva L., Rusinek H., Zhang J. L., Chen Q., & Lee V. S. Estimates of glomerular filtration rate from MR renography and tracer kinetic models. J. Magn. Reson. Imaging 29, 371-382 (2009
    • (2009) J. Magn. Reson. Imaging , vol.29 , pp. 371-382
    • Bokacheva, L.1    Rusinek, H.2    Zhang, J.L.3    Chen, Q.4    Lee, V.S.5
  • 74
    • 84875696482 scopus 로고    scopus 로고
    • Mechanisms of hypoxia responses in renal tissue
    • Haase V. H. Mechanisms of hypoxia responses in renal tissue. J. Am. Soc. Nephrol. 24, 537-541 (2013
    • (2013) J. Am. Soc. Nephrol , vol.24 , pp. 537-541
    • Haase, V.H.1
  • 75
    • 76349122683 scopus 로고    scopus 로고
    • Diabetic nephropathy: A disorder of oxygen metabolism?
    • Miyata T., & van Ypersele de Strihou C. Diabetic nephropathy: a disorder of oxygen metabolism?. Nat. Rev. Nephrol. 6, 83-95 (2009
    • (2009) Nat. Rev. Nephrol , vol.6 , pp. 83-95
    • Miyata, T.1    Van Ypersele, D.2    Strihou, C.3
  • 76
    • 84904123392 scopus 로고    scopus 로고
    • Hypoxia in diabetic kidneys
    • Takiyama Y., & Haneda M. Hypoxia in diabetic kidneys. Biomed. Res. Int. 2014, 837421 (2014
    • (2014) Biomed. Res. Int , vol.2014 , pp. 837421
    • Takiyama, Y.1    Haneda, M.2
  • 77
    • 0029640011 scopus 로고
    • Hypoxia of the renal medulla - Its implications for disease
    • Brezis M., & Rosen S. Hypoxia of the renal medulla - its implications for disease. N. Engl. J. Med. 9, 647-655 (1995
    • (1995) N. Engl. J. Med , vol.9 , pp. 647-655
    • Brezis, M.1    Rosen, S.2
  • 78
    • 23044461489 scopus 로고    scopus 로고
    • Validation of quantitative bold mri measurements in kidney: Application to unilateral ureteral obstruction
    • Pedersen M., et al. Validation of quantitative BOLD MRI measurements in kidney: application to unilateral ureteral obstruction. Kidney Int. 67, 2305-2312 (2005
    • (2005) Kidney Int , vol.67 , pp. 2305-2312
    • Pedersen, M.1
  • 79
    • 0035035078 scopus 로고    scopus 로고
    • Changes in intrarenal oxygenation as evaluated by bold mri in a rat kidney model for radiocontrast nephropathy
    • Prasad P. V., Priatna A., Spokes K., & Epstein F. H. Changes in intrarenal oxygenation as evaluated by BOLD MRI in a rat kidney model for radiocontrast nephropathy. J. Magn. Reson. Imaging 13, 744-747 (2001
    • (2001) J. Magn. Reson. Imaging , vol.13 , pp. 744-747
    • Prasad, P.V.1    Priatna, A.2    Spokes, K.3    Epstein, F.H.4
  • 80
    • 0036511165 scopus 로고    scopus 로고
    • Effect of diabetes on renal medullary oxygenation during water diuresis
    • Epstein F. H., Veves A., & Prasad P. V. Effect of diabetes on renal medullary oxygenation during water diuresis. Diabetes Care 25, 575-578 (2002
    • (2002) Diabetes Care , vol.25 , pp. 575-578
    • Epstein, F.H.1    Veves, A.2    Prasad, P.V.3
  • 81
    • 0842349494 scopus 로고    scopus 로고
    • Kidney oxygenation during water diuresis and endothelial function in patients with type 2 diabetes and subjects at risk to develop diabetes
    • Economides P. A., et al. Kidney oxygenation during water diuresis and endothelial function in patients with type 2 diabetes and subjects at risk to develop diabetes. Metabolism 53, 222-227 (2004
    • (2004) Metabolism , vol.53 , pp. 222-227
    • Economides, P.A.1
  • 82
    • 79960957297 scopus 로고    scopus 로고
    • Noninvasive evaluation of kidney hypoxia and fibrosis using magnetic resonance imaging
    • Inoue T., et al. Noninvasive evaluation of kidney hypoxia and fibrosis using magnetic resonance imaging. J. Am. Soc. Nephrol. 22, 1429-1434 (2011
    • (2011) J. Am. Soc. Nephrol , vol.22 , pp. 1429-1434
    • Inoue, T.1
  • 83
    • 84858331247 scopus 로고    scopus 로고
    • Renal bold-mri does not reflect renal function in chronic kidney disease
    • Michaely H. J., et al. Renal BOLD-MRI does not reflect renal function in chronic kidney disease. Kidney Int. 81, 684-689 (2012
    • (2012) Kidney Int , vol.81 , pp. 684-689
    • Michaely, H.J.1
  • 84
    • 44349159590 scopus 로고    scopus 로고
    • The use of magnetic resonance to evaluate tissue oxygenation in renal artery stenosis
    • Textor S. C., et al. The use of magnetic resonance to evaluate tissue oxygenation in renal artery stenosis. J. Am. Soc. Nephrol. 19, 780-788 (2008
    • (2008) J. Am. Soc. Nephrol , vol.19 , pp. 780-788
    • Textor, S.C.1
  • 85
    • 0037213490 scopus 로고    scopus 로고
    • Renal oxygenation defects in the spontaneously hypertensive rat: Role of AT1 receptors
    • Welch W. J., Baumgärtl H., Lübbers D., & Wilcox C. S. Renal oxygenation defects in the spontaneously hypertensive rat: role of AT1 receptors. Kidney Int. 63, 202-208 (2003
    • (2003) Kidney Int , vol.63 , pp. 202-208
    • Welch, W.J.1    Baumgärtl, H.2    Lübbers, D.3    Wilcox, C.S.4
  • 86
    • 84895925499 scopus 로고    scopus 로고
    • Inhibition of the renin-angiotensin system affects kidney tissue oxygenation evaluated by magnetic resonance imaging in patients with chronic kidney disease
    • Siddiqi L., et al. Inhibition of the renin-angiotensin system affects kidney tissue oxygenation evaluated by magnetic resonance imaging in patients with chronic kidney disease. J. Clin. Hypertens. (Greenwich) 16, 214-218 (2014
    • (2014) J. Clin. Hypertens. (Greenwich , vol.16 , pp. 214-218
    • Siddiqi, L.1
  • 87
    • 77950465247 scopus 로고    scopus 로고
    • Preserved oxygenation despite reduced blood flow in poststenotic kidneys in human atherosclerotic renal artery stenosis
    • Gloviczki M. L., et al. Preserved oxygenation despite reduced blood flow in poststenotic kidneys in human atherosclerotic renal artery stenosis. Hypertension 55, 961-966 (2010
    • (2010) Hypertension , vol.55 , pp. 961-966
    • Gloviczki, M.L.1
  • 88
    • 84859856686 scopus 로고    scopus 로고
    • Angiotensin II receptor blocker partially ameliorated intrarenal hypoxia in chronic kidney disease patients: A pre-/post-study
    • Manotham K., et al. Angiotensin II receptor blocker partially ameliorated intrarenal hypoxia in chronic kidney disease patients: a pre-/post-study. Int. Med. J. 42, e33-e37 (2012
    • (2012) Int. Med. J. , vol.42 , pp. e33-e37
    • Manotham, K.1
  • 89
    • 33846708818 scopus 로고    scopus 로고
    • Functional evaluation of transplanted kidneys with diffusion-weighted and bold mr imaging: Initial experience
    • Thoeny H. C., et al. Functional evaluation of transplanted kidneys with diffusion-weighted and BOLD MR imaging: initial experience. Radiology 241, 812-821 (2006
    • (2006) Radiology , vol.241 , pp. 812-821
    • Thoeny, H.C.1
  • 90
    • 71049166862 scopus 로고    scopus 로고
    • Blood oxygen level-dependent and perfusion magnetic resonance imaging: Detecting differences in oxygen bioavailability and blood flow in transplanted kidneys
    • Sadowski E. A., et al. Blood oxygen level-dependent and perfusion magnetic resonance imaging: detecting differences in oxygen bioavailability and blood flow in transplanted kidneys. Magn. Reson. Imaging 28, 56-64 (2010
    • (2010) Magn. Reson. Imaging , vol.28 , pp. 56-64
    • Sadowski, E.A.1
  • 91
    • 48749124275 scopus 로고    scopus 로고
    • The significance of bold mri in differentiation between renal transplant rejection and acute tubular necrosis
    • Han F., et al. The significance of BOLD MRI in differentiation between renal transplant rejection and acute tubular necrosis. Nephrol. Dial. Transplant. 23, 2666-2672 (2008
    • (2008) Nephrol. Dial. Transplant , vol.23 , pp. 2666-2672
    • Han, F.1
  • 92
    • 84912096364 scopus 로고    scopus 로고
    • Blood oxygenation level-dependent MRI for assessment of renal oxygenation
    • Neugarten J., & Golestaneh L. Blood oxygenation level-dependent MRI for assessment of renal oxygenation. Int. J. Nephrol. Renovasc. Dis. 7, 421-435 (2014
    • (2014) Int. J. Nephrol. Renovasc. Dis , vol.7 , pp. 421-435
    • Neugarten, J.1    Golestaneh, L.2
  • 93
    • 84883186313 scopus 로고    scopus 로고
    • Human renovascular disease: Estimating fractional tissue hypoxia to analyze blood oxygen level-dependent MR
    • Saad A., et al. Human renovascular disease: estimating fractional tissue hypoxia to analyze blood oxygen level-dependent MR. Radiology 268, 770-778 (2013
    • (2013) Radiology , vol.268 , pp. 770-778
    • Saad, A.1
  • 94
    • 84904046130 scopus 로고    scopus 로고
    • Detailing the relation between renal T2∗ and renal tissue pO2 using an integrated approach of parametric magnetic resonance imaging and invasive physiological measurements
    • Pohlmann A., et al. Detailing the relation between renal T2∗ and renal tissue pO2 using an integrated approach of parametric magnetic resonance imaging and invasive physiological measurements. Invest. Radiol. 49, 547-560 (2014
    • (2014) Invest. Radiol , vol.49 , pp. 547-560
    • Pohlmann, A.1
  • 95
    • 0032823222 scopus 로고    scopus 로고
    • Effect of downstream cross-sectional area of an arterial bed on the resistive index and the early systolic acceleration
    • Bude R. O., & Rubin J. M. Effect of downstream cross-sectional area of an arterial bed on the resistive index and the early systolic acceleration. Radiology 212, 732-738 (1999
    • (1999) Radiology , vol.212 , pp. 732-738
    • Bude, R.O.1    Rubin, J.M.2
  • 96
    • 84928582639 scopus 로고    scopus 로고
    • Doppler-based renal resistive index for prediction of renal dysfunction reversibility: A systematic review and meta-analysis
    • Ninet S., et al. Doppler-based renal resistive index for prediction of renal dysfunction reversibility: a systematic review and meta-analysis. J. Crit. Care 30, 629-635 (2015
    • (2015) J. Crit. Care , vol.30 , pp. 629-635
    • Ninet, S.1
  • 97
    • 84866011208 scopus 로고    scopus 로고
    • Doppler resistive index to reflect regulation of renal vascular tone during sepsis and acute kidney injury
    • Dewitte A., et al. Doppler resistive index to reflect regulation of renal vascular tone during sepsis and acute kidney injury. Crit. Care 16, R165 (2012
    • (2012) Crit. Care , vol.16 , pp. R165
    • Dewitte, A.1
  • 98
    • 0036178291 scopus 로고    scopus 로고
    • Renal resistance index and progression of renal disease
    • Radermacher J., Ellis S., & Haller H. Renal resistance index and progression of renal disease. Hypertension 39, 699-703 (2002
    • (2002) Hypertension , vol.39 , pp. 699-703
    • Radermacher, J.1    Ellis, S.2    Haller, H.3
  • 99
    • 84896695971 scopus 로고    scopus 로고
    • Predictive role of renal resistive index for clinical outcome after revascularization in hypertensive patients with atherosclerotic renal artery stenosis: A monocentric observational study
    • Bruno R. M., et al. Predictive role of renal resistive index for clinical outcome after revascularization in hypertensive patients with atherosclerotic renal artery stenosis: a monocentric observational study. Cardiovasc. Ultrasound 12, 9 (2014
    • (2014) Cardiovasc. Ultrasound , vol.12 , pp. 9
    • Bruno, R.M.1
  • 100
    • 84865472336 scopus 로고    scopus 로고
    • Renal resistive index and cardiovascular and renal outcomes in essential hypertension
    • Doi Y., et al. Renal resistive index and cardiovascular and renal outcomes in essential hypertension. Hypertension 60, 770-777 (2012
    • (2012) Hypertension , vol.60 , pp. 770-777
    • Doi, Y.1
  • 101
    • 79953013155 scopus 로고    scopus 로고
    • Early measurement of pulsatility and resistive indexes: Correlation with long-term renal transplant function
    • McArthur C., Geddes C. C., & Baxter G. M. Early measurement of pulsatility and resistive indexes: correlation with long-term renal transplant function. Radiology 259, 278-285 (2011
    • (2011) Radiology , vol.259 , pp. 278-285
    • McArthur, C.1    Geddes, C.C.2    Baxter, G.M.3
  • 102
    • 84887028802 scopus 로고    scopus 로고
    • Intrarenal resistive index after renal transplantation
    • Naesens M., et al. Intrarenal resistive index after renal transplantation. N. Engl. J. Med. 369, 1797-1806 (2013
    • (2013) N. Engl. J. Med , vol.369 , pp. 1797-1806
    • Naesens, M.1
  • 103
    • 67650088834 scopus 로고    scopus 로고
    • Estimating glomerular filtration rate in kidney donors: A model constructed with renal volume measurements from donor CT scans
    • Herts B. R., et al. Estimating glomerular filtration rate in kidney donors: a model constructed with renal volume measurements from donor CT scans. Radiology 252, 109-116 (2009
    • (2009) Radiology , vol.252 , pp. 109-116
    • Herts, B.R.1
  • 104
    • 55549104022 scopus 로고    scopus 로고
    • Determination of split renal function by 3D reconstruction of CT angiograms: A comparison with gamma camera renography
    • Summerlin A. L., et al. Determination of split renal function by 3D reconstruction of CT angiograms: a comparison with gamma camera renography. AJR Am. J. Roentgenol. 191, 1552-1558 (2008
    • (2008) AJR Am. J. Roentgenol , vol.191 , pp. 1552-1558
    • Summerlin, A.L.1
  • 105
    • 84916613143 scopus 로고    scopus 로고
    • Chronic urinary obstruction: Evaluation of dynamic contrast-enhanced MR urography for measurement of split renal function
    • Claudon M., et al. Chronic urinary obstruction: evaluation of dynamic contrast-enhanced MR urography for measurement of split renal function. Radiology 273, 801-812 (2014
    • (2014) Radiology , vol.273 , pp. 801-812
    • Claudon, M.1
  • 106
    • 84934902347 scopus 로고    scopus 로고
    • Determination of single-kidney glomerular filtration rate in human subjects by using CT
    • Kwon S. H., Saad A., Herrmann S. M., Textor S. C., & Lerman L. O. Determination of single-kidney glomerular filtration rate in human subjects by using CT. Radiology 276, 490-498 (2015
    • (2015) Radiology , vol.276 , pp. 490-498
    • Kwon, S.H.1    Saad, A.2    Herrmann, S.M.3    Textor, S.C.4    Lerman, L.O.5
  • 107
    • 84883379282 scopus 로고    scopus 로고
    • Prediction and assessment of responses to renal artery revascularization with dynamic contrast-enhanced magnetic resonance imaging: A pilot study
    • Lim S. W., Chrysochou C., Buckley D. L., Kalra P. A., & Sourbron S. P. Prediction and assessment of responses to renal artery revascularization with dynamic contrast-enhanced magnetic resonance imaging: a pilot study. Am. J. Physiol. Renal Physiol. 305, F672-F678 (2013
    • (2013) Am. J. Physiol. Renal Physiol , vol.305 , pp. F672-F678
    • Lim, S.W.1    Chrysochou, C.2    Buckley, D.L.3    Kalra, P.A.4    Sourbron, S.P.5
  • 108
    • 79955028242 scopus 로고    scopus 로고
    • Kidney function: Glomerular filtration rate measurement with MR renography in patients with cirrhosis
    • Vivier P. H., et al. Kidney function: glomerular filtration rate measurement with MR renography in patients with cirrhosis. Radiology 259, 462-470 (2011
    • (2011) Radiology , vol.259 , pp. 462-470
    • Vivier, P.H.1
  • 109
    • 24744450987 scopus 로고    scopus 로고
    • Glomerular filtration rate measured using the Patlak plot technique and contrast-enhanced dynamic MRI with different amounts of gadolinium-DTPA
    • Hackstein N., Kooijman H., Tomaselli S., & Rau W. S. Glomerular filtration rate measured using the Patlak plot technique and contrast-enhanced dynamic MRI with different amounts of gadolinium-DTPA. J. Magn. Reson. Imaging 22, 406-414 (2005
    • (2005) J. Magn. Reson. Imaging , vol.22 , pp. 406-414
    • Hackstein, N.1    Kooijman, H.2    Tomaselli, S.3    Rau, W.S.4
  • 110
    • 34247862083 scopus 로고    scopus 로고
    • Renal function measurements from MR renography and a simplified multicompartmental model
    • Lee V. S., et al. Renal function measurements from MR renography and a simplified multicompartmental model. Am. J. Physiol. Renal Physiol. 292, F1548-F1559 (2007
    • (2007) Am. J. Physiol. Renal Physiol , vol.292 , pp. F1548-F1559
    • Lee, V.S.1
  • 111
    • 84860408944 scopus 로고    scopus 로고
    • Quantitative evaluation of acute renal transplant dysfunction with low-dose three-dimensional MR renography
    • Yamamoto A., et al. Quantitative evaluation of acute renal transplant dysfunction with low-dose three-dimensional MR renography. Radiology 260, 781-789 (2011
    • (2011) Radiology , vol.260 , pp. 781-789
    • Yamamoto, A.1
  • 112
    • 37149023849 scopus 로고    scopus 로고
    • Measurement of glomerular filtration rate with magnetic resonance imaging: Principles, limitations, and expectations
    • Grenier N., et al. Measurement of glomerular filtration rate with magnetic resonance imaging: principles, limitations, and expectations. Semin. Nucl. Med. 38, 47-55 (2008
    • (2008) Semin. Nucl. Med , vol.38 , pp. 47-55
    • Grenier, N.1
  • 113
    • 1542782091 scopus 로고    scopus 로고
    • Biochemical characterization of human brain and kidney tissues by magnetic resonance spectroscopy
    • Tugnoli V., & Tosi M. R. Biochemical characterization of human brain and kidney tissues by magnetic resonance spectroscopy. Ital. J. Biochem. 52, 80-86 (2003
    • (2003) Ital. J. Biochem , vol.52 , pp. 80-86
    • Tugnoli, V.1    Tosi, M.R.2
  • 114
    • 73949133557 scopus 로고    scopus 로고
    • Production of hyperpolarized [1 4 13C2]malate from [1,4 13C2]fumarate is a marker of cell necrosis and treatment response in tumors
    • Gallagher F. A., et al. Production of hyperpolarized [1,4 13C2]malate from [1,4 13C2]fumarate is a marker of cell necrosis and treatment response in tumors. Proc Natl Acad. Sci. USA 106, 19801-19806 (2009
    • (2009) Proc Natl Acad. Sci. USA , vol.106 , pp. 19801-19806
    • Gallagher, F.A.1
  • 115
    • 84865191464 scopus 로고    scopus 로고
    • Magnetic resonance imaging with hyperpolarized [1,4-13C2]fumarate allows detection of early renal acute tubular necrosis
    • Clatworthy M. R., et al. Magnetic resonance imaging with hyperpolarized [1,4-13C2]fumarate allows detection of early renal acute tubular necrosis. Proc. Natl Acad. Sci. USA 109, 13374-13379 (2012
    • (2012) Proc. Natl Acad. Sci. USA , vol.109 , pp. 13374-13379
    • Clatworthy, M.R.1
  • 116
    • 33845261387 scopus 로고    scopus 로고
    • Sodium MRI of the human kidney at 3 Tesla
    • Maril N., et al. Sodium MRI of the human kidney at 3 Tesla. Magn. Reson. Med. 56, 1229-1234 (2006
    • (2006) Magn. Reson. Med , vol.56 , pp. 1229-1234
    • Maril, N.1
  • 117
    • 1342343892 scopus 로고    scopus 로고
    • Functional sodium magnetic resonance imaging of the intact rat kidney
    • Maril N., Margalit R., Mispelter J., & Degani H. Functional sodium magnetic resonance imaging of the intact rat kidney. Kidney Int. 65, 927-935 (2004
    • (2004) Kidney Int , vol.65 , pp. 927-935
    • Maril, N.1    Margalit, R.2    Mispelter, J.3    Degani, H.4
  • 118
    • 84860390518 scopus 로고    scopus 로고
    • Quantitative and qualitative 23Na MR imaging of the human kidneys at 3 T: Before and after a water load
    • Haneder S., et al. Quantitative and qualitative 23Na MR imaging of the human kidneys at 3 T: before and after a water load. Radiology 260, 857-865 (2011
    • (2011) Radiology , vol.260 , pp. 857-865
    • Haneder, S.1
  • 119
    • 32544437043 scopus 로고    scopus 로고
    • Detection of evolving acute tubular necrosis with renal 23Na MRI: Studies in rats
    • Maril N., Margalit R., Rosen S., Heyman S. N., & Degani H. Detection of evolving acute tubular necrosis with renal 23Na MRI: studies in rats. Kidney Int. 69, 765-768 (2006
    • (2006) Kidney Int , vol.69 , pp. 765-768
    • Maril, N.1    Margalit, R.2    Rosen, S.3    Heyman, S.N.4    Degani, H.5
  • 121
    • 84883242235 scopus 로고    scopus 로고
    • Imaging the pH evolution of an acute kidney injury model by means of iopamidol, a MRI-CEST pH responsive contrast agent
    • Longo D. L., Busato A., Lanzardo S., Antico F., & Aime S. Imaging the pH evolution of an acute kidney injury model by means of iopamidol, a MRI-CEST pH responsive contrast agent. Magn. Reson. Med. 70, 859-864 (2012
    • (2012) Magn. Reson. Med , vol.70 , pp. 859-864
    • Longo, D.L.1    Busato, A.2    Lanzardo, S.3    Antico, F.4    Aime, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.