메뉴 건너뛰기




Volumn 15, Issue 1, 2014, Pages

Inter-study reproducibility of arterial spin labeling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla

Author keywords

Arterial spin labelling; Magnetic resonance imaging; Renal blood flow; Renal perfusion; Renal physiology

Indexed keywords

ADULT; ARTERIAL SPIN LABELING; ARTICLE; BLOOD PRESSURE; COMPARATIVE STUDY; CORRELATIONAL STUDY; ESTIMATED GLOMERULAR FILTRATION RATE; FEMALE; HUMAN; KIDNEY PERFUSION; KIDNEY SIZE; MALE; NORMAL HUMAN; REPRODUCIBILITY;

EID: 84893171318     PISSN: None     EISSN: 14712369     Source Type: Journal    
DOI: 10.1186/1471-2369-15-23     Document Type: Article
Times cited : (50)

References (32)
  • 1
    • 34447619345 scopus 로고    scopus 로고
    • Evidence that renal arterial-venous oxygen shunting contributes to dynamic regulation of renal oxygenation
    • Leong CL, Anderson WP, O'Connor PM, Evans RG: Evidence that renal arterial-venous oxygen shunting contributes to dynamic regulation of renal oxygenation. Am J Physiol Renal Physiol 2007, 292(6):F1726-F1733.
    • (2007) Am J Physiol Renal Physiol , vol.292 , Issue.6 , pp. F1726-F1733
    • Leong, C.L.1    Anderson, W.P.2    O'Connor, P.M.3    Evans, R.G.4
  • 2
    • 0026773056 scopus 로고
    • Determinants of intrarenal oxygenation: Factors in acute renal failure
    • Rosen S, Epstein FH, Brezis M: Determinants of intrarenal oxygenation: factors in acute renal failure. Ren Fail 1992, 14(3):321-325.
    • (1992) Ren Fail , vol.14 , Issue.3 , pp. 321-325
    • Rosen, S.1    Epstein, F.H.2    Brezis, M.3
  • 4
    • 0015530123 scopus 로고
    • Measurement of renal function without urine collection. A critical evaluation of the constant-infusion technic for determination of inulin and para-Aminohippurate
    • Cole BR, Giangiacomo J, Ingelfinger JR, Robson AM: Measurement of renal function without urine collection. A critical evaluation of the constant-infusion technic for determination of inulin and para-Aminohippurate. N Engl J Med 1972, 287(22):1109-1114.
    • (1972) N Engl J Med , vol.287 , Issue.22 , pp. 1109-1114
    • Cole, B.R.1    Giangiacomo, J.2    Ingelfinger, J.R.3    Robson, A.M.4
  • 6
    • 34548671875 scopus 로고    scopus 로고
    • Gadolinium-enhanced MR imaging and nephrogenic systemic fibrosis: Retrospective study of a renal replacement therapy cohort1
    • Collidge TA, Thomson PC, Mark PB, Traynor JP, Jardine AG, Morris STW, Simpson K, Roditi GH: Gadolinium-enhanced MR imaging and nephrogenic systemic fibrosis: retrospective study of a renal replacement therapy cohort1. Radiology 2007, 245(1):168-175.
    • (2007) Radiology , vol.245 , Issue.1 , pp. 168-175
    • Collidge, T.A.1    Thomson, P.C.2    Mark, P.B.3    Traynor, J.P.4    Jardine, A.G.5    Stw, M.6    Simpson, K.7    Roditi, G.H.8
  • 7
    • 33747590330 scopus 로고    scopus 로고
    • Non-invasive measurement of perfusion: A critical review of arterial spin labelling techniques
    • Petersen ET, Zimine I, Ho YC, Golay X: Non-invasive measurement of perfusion: A critical review of arterial spin labelling techniques. Br J Radiol 2006, 79(944):688-701.
    • (2006) Br J Radiol , vol.79 , Issue.944 , pp. 688-701
    • Petersen, E.T.1    Zimine, I.2    Ho, Y.C.3    Golay, X.4
  • 8
    • 84863393460 scopus 로고    scopus 로고
    • Repeatability of renal arterial spin labelling MRI in healthy subjects
    • Cutajar M, Thomas DL, Banks T, Clark CA, Golay X, Gordon I: Repeatability of renal arterial spin labelling MRI in healthy subjects. MAGMA 2012, 25(2):145-153.
    • (2012) MAGMA , vol.25 , Issue.2 , pp. 145-153
    • Cutajar, M.1    Thomas, D.L.2    Banks, T.3    Clark, C.A.4    Golay, X.5    Gordon, I.6
  • 11
    • 77950190399 scopus 로고    scopus 로고
    • Measurement of kidney perfusion by magnetic resonance imaging: Comparison of MRI with arterial spin labeling to para-Aminohippuric acid plasma clearance in male subjects with metabolic syndrome
    • Ritt M, Janka R, Schneider MP, Martirosian P, Hornegger J, Bautz W, Uder M, Schmieder RE: Measurement of kidney perfusion by magnetic resonance imaging: comparison of MRI with arterial spin labeling to para-Aminohippuric acid plasma clearance in male subjects with metabolic syndrome. Nephrol Dial Transplant 2010, 25(4):1126-1133.
    • (2010) Nephrol Dial Transplant , vol.25 , Issue.4 , pp. 1126-1133
    • Ritt, M.1    Janka, R.2    Schneider, M.P.3    Martirosian, P.4    Hornegger, J.5    Bautz, W.6    Uder, M.7    Schmieder, R.E.8
  • 12
    • 0033011327 scopus 로고    scopus 로고
    • Renal volume measurements: Accuracy and repeatability of US compared with that of MR imaging
    • Bakker J, Olree M, Kaatee R, de Lange EE, Moons KG, Beutler JJ, Beek FJ: Renal volume measurements: Accuracy and repeatability of US compared with that of MR imaging. Radiology 1999, 211(3):623-628.
    • (1999) Radiology , vol.211 , Issue.3 , pp. 623-628
    • Bakker, J.1    Olree, M.2    Kaatee, R.3    De Lange, E.E.4    Moons, K.G.5    Beutler, J.J.6    Beek, F.J.7
  • 14
    • 50249122257 scopus 로고    scopus 로고
    • Parametric image alignment using enhanced correlation coefficient maximization
    • Evangelidis GD, Psarakis EZ: Parametric image alignment using enhanced correlation coefficient maximization. IEEE Trans Pattern Anal Mach Intell 2008, 30(10):1858-1865.
    • (2008) IEEE Trans Pattern Anal Mach Intell , vol.30 , Issue.10 , pp. 1858-1865
    • Evangelidis, G.D.1    Psarakis, E.Z.2
  • 15
    • 0842285725 scopus 로고    scopus 로고
    • FAIR true-FISP perfusion imaging of the kidneys
    • Martirosian P, Klose U, Mader I, Schick F: FAIR true-FISP perfusion imaging of the kidneys. Magn Reson Med 2004, 51(2):353-361.
    • (2004) Magn Reson Med , vol.51 , Issue.2 , pp. 353-361
    • Martirosian, P.1    Klose, U.2    Mader, I.3    Schick, F.4
  • 16
    • 1342330052 scopus 로고    scopus 로고
    • MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results
    • de Bazelaire CM, Duhamel GD, Rofsky NM, Alsop DC: MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results. Radiology 2004, 230(3):652-659.
    • (2004) Radiology , vol.230 , Issue.3 , pp. 652-659
    • De Bazelaire, C.M.1    Duhamel, G.D.2    Rofsky, N.M.3    Alsop, D.C.4
  • 17
    • 84880888018 scopus 로고    scopus 로고
    • Modified look-locker inversion recovery T1 mapping indices: Assessment of accuracy and reproducibility between magnetic resonance scanners
    • Raman FS, Kawel-Boehm N, Gai N, Freed M, Han J, Liu CY, Lima JA, Bluemke DA, Liu S: Modified look-locker inversion recovery T1 mapping indices: Assessment of accuracy and reproducibility between magnetic resonance scanners. J Cardiovasc Magn Reson 2013, 15:64.
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 64
    • Raman, F.S.1    Kawel-Boehm, N.2    Gai, N.3    Freed, M.4    Han, J.5    Liu, C.Y.6    Lima, J.A.7    Bluemke, D.A.8    Liu, S.9
  • 19
    • 81555212314 scopus 로고    scopus 로고
    • Renal perfusion 3-T MR imaging: A comparative study of arterial spin labeling and dynamic contrast-enhanced techniques
    • Wu WC, Su MY, Chang CC, Tseng WY, Liu KL: Renal perfusion 3-T MR imaging: A comparative study of arterial spin labeling and dynamic contrast-enhanced techniques. Radiology 2011, 261(3):845-853.
    • (2011) Radiology , vol.261 , Issue.3 , pp. 845-853
    • Wu, W.C.1    Su, M.Y.2    Chang, C.C.3    Tseng, W.Y.4    Liu, K.L.5
  • 21
    • 29144434140 scopus 로고    scopus 로고
    • High resolution MR perfusion imaging of the kidneys at 3 Tesla without administration of contrast media
    • Boss A, Martirosian P, Graf H, Claussen CD, Schlemmer HP, Schick F: High resolution MR perfusion imaging of the kidneys at 3 Tesla without administration of contrast media. Rofo 2005, 177(12):1625-1630.
    • (2005) Rofo , vol.177 , Issue.12 , pp. 1625-1630
    • Boss, A.1    Martirosian, P.2    Graf, H.3    Claussen, C.D.4    Schlemmer, H.P.5    Schick, F.6
  • 22
    • 79958266556 scopus 로고    scopus 로고
    • Reproducibility of renal perfusion MR imaging in native and transplanted kidneys using non-contrast arterial spin labeling
    • Artz NS, Sadowski EA, Wentland AL, Djamali A, Grist TM, Seo S, Fain SB: Reproducibility of renal perfusion MR imaging in native and transplanted kidneys using non-contrast arterial spin labeling. J Magn Reson Imaging 2011, 33(6):1414-1421.
    • (2011) J Magn Reson Imaging , vol.33 , Issue.6 , pp. 1414-1421
    • Artz, N.S.1    Sadowski, E.A.2    Wentland, A.L.3    Djamali, A.4    Grist, T.M.5    Seo, S.6    Fain, S.B.7
  • 23
    • 78751637427 scopus 로고    scopus 로고
    • Comparing kidney perfusion using noncontrast arterial spin labeling MRI and microsphere methods in an interventional swine model
    • Artz NS, Wentland AL, Sadowski EA, Djamali A, Grist TM, Seo S, Fain SB: Comparing kidney perfusion using noncontrast arterial spin labeling MRI and microsphere methods in an interventional swine model. Invest Radiol 2011, 46(2):124-131.
    • (2011) Invest Radiol , vol.46 , Issue.2 , pp. 124-131
    • Artz, N.S.1    Wentland, A.L.2    Sadowski, E.A.3    Djamali, A.4    Grist, T.M.5    Seo, S.6    Fain, S.B.7
  • 24
    • 77952709881 scopus 로고    scopus 로고
    • Multislice perfusion of the kidneys using parallel imaging: Image acquisition and analysis strategies
    • Gardener AG, Francis ST: Multislice perfusion of the kidneys using parallel imaging: image acquisition and analysis strategies. Magn Reson Med 2010, 63(6):1627-1636.
    • (2010) Magn Reson Med , vol.63 , Issue.6 , pp. 1627-1636
    • Gardener, A.G.1    Francis, S.T.2
  • 25
    • 0031022848 scopus 로고    scopus 로고
    • Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques
    • Ye FQ, Mattay VS, Jezzard P, Frank JA, Weinberger DR, McLaughlin AC: Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques. Magn Reson Med 1997, 37(2):226-235.
    • (1997) Magn Reson Med , vol.37 , Issue.2 , pp. 226-235
    • Ye, F.Q.1    Mattay, V.S.2    Jezzard, P.3    Frank, J.A.4    Weinberger, D.R.5    McLaughlin, A.C.6
  • 26
    • 0018832394 scopus 로고
    • Measurement of renal clearance of inulin and PAH in the steady state without urine collection
    • Schnurr E, Lahme W, Kuppers H: Measurement of renal clearance of inulin and PAH in the steady state without urine collection. Clin Nephrol 1980, 13(1):26-29.
    • (1980) Clin Nephrol , vol.13 , Issue.1 , pp. 26-29
    • Schnurr, E.1    Lahme, W.2    Kuppers, H.3
  • 29
    • 84870250946 scopus 로고    scopus 로고
    • Renal blood flow fractional excretion of sodium and acute kidney injury: Time for a new paradigm?
    • Prowle J, Bagshaw SM, Bellomo R: Renal blood flow, fractional excretion of sodium and acute kidney injury: Time for a new paradigm? Curr Opin Crit Care 2012, 18(6):585-592.
    • (2012) Curr Opin Crit Care , vol.18 , Issue.6 , pp. 585-592
    • Prowle, J.1    Bagshaw, S.M.2    Bellomo, R.3
  • 31
    • 77958101209 scopus 로고    scopus 로고
    • Renovascular hypertension and ischemic nephropathy
    • Textor SC, Lerman L: Renovascular hypertension and ischemic nephropathy. Am J Hypertens 2010, 23(11):1159-1169.
    • (2010) Am J Hypertens , vol.23 , Issue.11 , pp. 1159-1169
    • Textor, S.C.1    Lerman, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.