-
1
-
-
0026922793
-
Rates of osseointegration of dental implants with regard to anatomical location
-
Drago C.J. Rates of osseointegration of dental implants with regard to anatomical location. J Prosthodont 1 (1992) 29-31
-
(1992)
J Prosthodont
, vol.1
, pp. 29-31
-
-
Drago, C.J.1
-
2
-
-
0033172716
-
Long-term evaluation of 282 implants in maxillary and mandibular molar positions: a prospective study
-
Becker W., Becker B.E., Alsuwyed A., and Al-Mubarak S. Long-term evaluation of 282 implants in maxillary and mandibular molar positions: a prospective study. J Periodontol 70 (1999) 896-901
-
(1999)
J Periodontol
, vol.70
, pp. 896-901
-
-
Becker, W.1
Becker, B.E.2
Alsuwyed, A.3
Al-Mubarak, S.4
-
3
-
-
35848971210
-
Implant zones of the jaws: implant location and related success rate
-
Tolstunov L. Implant zones of the jaws: implant location and related success rate. J Oral Implantol 33 (2007) 211-220
-
(2007)
J Oral Implantol
, vol.33
, pp. 211-220
-
-
Tolstunov, L.1
-
4
-
-
0002172340
-
Patient selection and preparation
-
Branemark P.I., Zarb G.A., and Albrektsson T. (Eds), Quintessence, Chicago
-
Lekholm U., and Zarb G.A. Patient selection and preparation. In: Branemark P.I., Zarb G.A., and Albrektsson T. (Eds). Tissue-integrated prostheses: osseointegration in clinical dentistry (1985), Quintessence, Chicago 199-210
-
(1985)
Tissue-integrated prostheses: osseointegration in clinical dentistry
, pp. 199-210
-
-
Lekholm, U.1
Zarb, G.A.2
-
6
-
-
0033067941
-
Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement
-
discussion 706-8.
-
Misch C.E., Qu Z., and Bidez M.W. Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement. J Oral Maxillofac Surg 57 (1999) 700-706 discussion 706-8.
-
(1999)
J Oral Maxillofac Surg
, vol.57
, pp. 700-706
-
-
Misch, C.E.1
Qu, Z.2
Bidez, M.W.3
-
7
-
-
0034303223
-
Anisotropic elastic properties of cancellous bone from a human edentulous mandible
-
O'Mahony A.M., Williams J.L., Katz J.O., and Spencer P. Anisotropic elastic properties of cancellous bone from a human edentulous mandible. Clin Oral Implants Res 11 (2000) 415-421
-
(2000)
Clin Oral Implants Res
, vol.11
, pp. 415-421
-
-
O'Mahony, A.M.1
Williams, J.L.2
Katz, J.O.3
Spencer, P.4
-
8
-
-
0037417008
-
Variations in cortical material properties throughout the human dentate mandible
-
Schwartz-Dabney C.L., and Dechow P.C. Variations in cortical material properties throughout the human dentate mandible. Am J Phys Anthropol 120 (2003) 252-277
-
(2003)
Am J Phys Anthropol
, vol.120
, pp. 252-277
-
-
Schwartz-Dabney, C.L.1
Dechow, P.C.2
-
9
-
-
0032018553
-
A comparison of maxillary and mandibular bone mineral densities
-
Devlin H., Horner K., and Ledgerton D. A comparison of maxillary and mandibular bone mineral densities. J Prosthet Dent 79 (1988) 323-327
-
(1988)
J Prosthet Dent
, vol.79
, pp. 323-327
-
-
Devlin, H.1
Horner, K.2
Ledgerton, D.3
-
10
-
-
0035261160
-
Bone classification: an objective scale of bone density using the computerized tomography scan
-
Norton M.R., and Gamble C. Bone classification: an objective scale of bone density using the computerized tomography scan. Clin Oral Implants Res 12 (2001) 79-84
-
(2001)
Clin Oral Implants Res
, vol.12
, pp. 79-84
-
-
Norton, M.R.1
Gamble, C.2
-
11
-
-
0018564497
-
The influence of functional use of endosseous dental implants on the tissue-implant interface. I. Histological aspects
-
Brunski J.B., Moccia Jr. A.F., Pollack S.R., Korostoff E., and Trachtenberg D.I. The influence of functional use of endosseous dental implants on the tissue-implant interface. I. Histological aspects. J Dent Res 58 (1979) 1953-1969
-
(1979)
J Dent Res
, vol.58
, pp. 1953-1969
-
-
Brunski, J.B.1
Moccia Jr., A.F.2
Pollack, S.R.3
Korostoff, E.4
Trachtenberg, D.I.5
-
12
-
-
0026740505
-
Biomechanical factors affecting the bone-dental implant interface
-
Brunski J.B. Biomechanical factors affecting the bone-dental implant interface. Clin Mater 10 (1992) 153-201
-
(1992)
Clin Mater
, vol.10
, pp. 153-201
-
-
Brunski, J.B.1
-
13
-
-
44349141722
-
Initial stability measurement of dental implants placed in different anatomical regions of fresh human cadaver jawbone
-
Seong W.J., Holte J.E., Holtan J.R., Olin P.S., Hodges J.S., and Ko C.C. Initial stability measurement of dental implants placed in different anatomical regions of fresh human cadaver jawbone. J Prosthet Dent 99 (2008) 425-434
-
(2008)
J Prosthet Dent
, vol.99
, pp. 425-434
-
-
Seong, W.J.1
Holte, J.E.2
Holtan, J.R.3
Olin, P.S.4
Hodges, J.S.5
Ko, C.C.6
-
14
-
-
0345304947
-
Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants
-
Nkenke E., Hahn M., Weinzierl K., Radespiel-Tröger M., Neukam F.W., and Engelke K. Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants. Clin Oral Implants Res 14 (2003) 601-609
-
(2003)
Clin Oral Implants Res
, vol.14
, pp. 601-609
-
-
Nkenke, E.1
Hahn, M.2
Weinzierl, K.3
Radespiel-Tröger, M.4
Neukam, F.W.5
Engelke, K.6
-
15
-
-
28844480575
-
Influence of cortical bone thickness and implant length on implant stability at the time of surgery-clinical, prospective, biomechanical, and imaging study
-
Miyamoto I., Tsuboi Y., Wada E., Suwa H., and Iizuka T. Influence of cortical bone thickness and implant length on implant stability at the time of surgery-clinical, prospective, biomechanical, and imaging study. Bone 37 (2005) 776-780
-
(2005)
Bone
, vol.37
, pp. 776-780
-
-
Miyamoto, I.1
Tsuboi, Y.2
Wada, E.3
Suwa, H.4
Iizuka, T.5
-
16
-
-
0031260276
-
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
-
Rho J.Y., Tsui T.Y., and Pharr G.M. Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation. Biomaterials 18 (1997) 1325-1330
-
(1997)
Biomaterials
, vol.18
, pp. 1325-1330
-
-
Rho, J.Y.1
Tsui, T.Y.2
Pharr, G.M.3
-
17
-
-
0002740317
-
Biomechanics of cortical and trabecular bone; Implications for assessment of fracture risk
-
Mow V.C., and Hayes W. (Eds), Lippincott-Raven, Philadelphia
-
Hayes W., and Bouxsein M. Biomechanics of cortical and trabecular bone; Implications for assessment of fracture risk. In: Mow V.C., and Hayes W. (Eds). Basic orthopaedic biomechanics. 2nd ed. (1997), Lippincott-Raven, Philadelphia 86-88
-
(1997)
Basic orthopaedic biomechanics. 2nd ed.
, pp. 86-88
-
-
Hayes, W.1
Bouxsein, M.2
-
18
-
-
0030224153
-
Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
-
Meredith N., Alleyne D., and Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 7 (1996) 261-267
-
(1996)
Clin Oral Implants Res
, vol.7
, pp. 261-267
-
-
Meredith, N.1
Alleyne, D.2
Cawley, P.3
-
19
-
-
7944234226
-
Predicting osseointegration by means of implant primary stability
-
Nedir R., Bischof M., Szmukler-Moncler S., Bernard J.P., and Samson J. Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res 15 (2004) 520-528
-
(2004)
Clin Oral Implants Res
, vol.15
, pp. 520-528
-
-
Nedir, R.1
Bischof, M.2
Szmukler-Moncler, S.3
Bernard, J.P.4
Samson, J.5
-
20
-
-
7944232457
-
Implant stability measurement of delayed and immediately loaded implants during healing
-
Bischof M., Nedir R., Szmukler-Moncler S., Berbard J.P., and Samson J. Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res 15 (2004) 529-539
-
(2004)
Clin Oral Implants Res
, vol.15
, pp. 529-539
-
-
Bischof, M.1
Nedir, R.2
Szmukler-Moncler, S.3
Berbard, J.P.4
Samson, J.5
-
21
-
-
25444498330
-
A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants
-
Balshi S.F., Allen F.D., Wolfinger G.J., and Balshi T.J. A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants. Int J Oral Maxillofac Implants 20 (2005) 584-594
-
(2005)
Int J Oral Maxillofac Implants
, vol.20
, pp. 584-594
-
-
Balshi, S.F.1
Allen, F.D.2
Wolfinger, G.J.3
Balshi, T.J.4
-
22
-
-
34548563340
-
Identification of stability changes for immediately placed dental implants
-
West J.D., and Oates T.W. Identification of stability changes for immediately placed dental implants. Int J Oral Maxillofac Implants 22 (2007) 623-630
-
(2007)
Int J Oral Maxillofac Implants
, vol.22
, pp. 623-630
-
-
West, J.D.1
Oates, T.W.2
-
23
-
-
0031108095
-
The use of the Periotest value as the initial success criteria of an implant: 8-year report
-
Aparicio C. The use of the Periotest value as the initial success criteria of an implant: 8-year report. Int J Periodontics Restorative Dent 17 (1997) 150-161
-
(1997)
Int J Periodontics Restorative Dent
, vol.17
, pp. 150-161
-
-
Aparicio, C.1
-
24
-
-
0033169706
-
Immediate loading of modular transitional implants: a histologic and histomorphometric study in dogs
-
Zubery Y., Bichacho N., Moses O., and Tal H. Immediate loading of modular transitional implants: a histologic and histomorphometric study in dogs. Int J Periodontics Restorative Dent 19 (1999) 343-353
-
(1999)
Int J Periodontics Restorative Dent
, vol.19
, pp. 343-353
-
-
Zubery, Y.1
Bichacho, N.2
Moses, O.3
Tal, H.4
-
25
-
-
0024764157
-
Comparison of the trabecular and cortical tissue moduli from human iliac crests
-
Kuhn J.L., Goldstein S.A., Choi K., London M., Feldkamp L.A., and Matthews L.S. Comparison of the trabecular and cortical tissue moduli from human iliac crests. J Orthop Res 7 (1989) 876-884
-
(1989)
J Orthop Res
, vol.7
, pp. 876-884
-
-
Kuhn, J.L.1
Goldstein, S.A.2
Choi, K.3
London, M.4
Feldkamp, L.A.5
Matthews, L.S.6
-
26
-
-
0019947037
-
A method for the study of undecalcified bones and teeth with attached soft tissues. The Säge-Schliff (sawing and grinding) technique
-
Donath K., and Breuner G. A method for the study of undecalcified bones and teeth with attached soft tissues. The Säge-Schliff (sawing and grinding) technique. J Oral Pathol 11 (1982) 318-326
-
(1982)
J Oral Pathol
, vol.11
, pp. 318-326
-
-
Donath, K.1
Breuner, G.2
-
27
-
-
0033119284
-
Elastic properties of microstructural components of human bone tissue as measured by nanoindentation
-
Rho J.Y., Roy II M.E., Tsui T.Y., and Pharr G.M. Elastic properties of microstructural components of human bone tissue as measured by nanoindentation. J Biomed Mater Res 45 (1999) 48-54
-
(1999)
J Biomed Mater Res
, vol.45
, pp. 48-54
-
-
Rho, J.Y.1
Roy II, M.E.2
Tsui, T.Y.3
Pharr, G.M.4
-
28
-
-
0026875935
-
An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments
-
Oliver W.C., and Pharr G.M. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments. J Mater Res 7 (1992) 1564-1583
-
(1992)
J Mater Res
, vol.7
, pp. 1564-1583
-
-
Oliver, W.C.1
Pharr, G.M.2
-
29
-
-
0030693338
-
Comparison of bone density measurement techniques: DXA and Archimedes' principle
-
Keenan M.J., Hegsted M., Jones K.L., Delany J.P., Kime J.C., Melancon L.E., et al. Comparison of bone density measurement techniques: DXA and Archimedes' principle. J Bone Miner Res 12 (1997) 1903-1907
-
(1997)
J Bone Miner Res
, vol.12
, pp. 1903-1907
-
-
Keenan, M.J.1
Hegsted, M.2
Jones, K.L.3
Delany, J.P.4
Kime, J.C.5
Melancon, L.E.6
-
30
-
-
0032059195
-
Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability
-
Meredith N., Friberg B., Sennerby L., and Aparicio C. Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability. Int J Prosthodont 11 (1998) 269-275
-
(1998)
Int J Prosthodont
, vol.11
, pp. 269-275
-
-
Meredith, N.1
Friberg, B.2
Sennerby, L.3
Aparicio, C.4
-
31
-
-
0014373686
-
Changes in human mandibular structure with age
-
Atkinson P.J., and Woodhead C. Changes in human mandibular structure with age. Arch Oral Biol 13 (1968) 1453-1464
-
(1968)
Arch Oral Biol
, vol.13
, pp. 1453-1464
-
-
Atkinson, P.J.1
Woodhead, C.2
-
32
-
-
0036715298
-
Edentulation alters material properties of cortical bone in the human mandible
-
Schwartz-Dabney C.L., and Dechow P.C. Edentulation alters material properties of cortical bone in the human mandible. J Dent Res 81 (2002) 613-617
-
(2002)
J Dent Res
, vol.81
, pp. 613-617
-
-
Schwartz-Dabney, C.L.1
Dechow, P.C.2
-
33
-
-
0017377404
-
Fracture mechanics parameters for compact bone-effects of density and specimen thickness
-
Wright T.M., and Hayes W.C. Fracture mechanics parameters for compact bone-effects of density and specimen thickness. J Biomech 10 (1977) 419-430
-
(1977)
J Biomech
, vol.10
, pp. 419-430
-
-
Wright, T.M.1
Hayes, W.C.2
-
34
-
-
0021361396
-
Fracture mechanics of bone-the effects of density, specimen thickness and crack velocity on longitudinal fracture
-
Behiri J.C., and Bonfield W. Fracture mechanics of bone-the effects of density, specimen thickness and crack velocity on longitudinal fracture. J Biomech 17 (1984) 25-34
-
(1984)
J Biomech
, vol.17
, pp. 25-34
-
-
Behiri, J.C.1
Bonfield, W.2
-
35
-
-
0031817691
-
Changes in the fracture toughness of bone may not be reflected in its mineral density, porosity, and tensile properties
-
Wang X.D., Masilamani N.S., Mabrey J.D., Alder M.E., and Agrawal C.M. Changes in the fracture toughness of bone may not be reflected in its mineral density, porosity, and tensile properties. Bone 23 (1998) 67-72
-
(1998)
Bone
, vol.23
, pp. 67-72
-
-
Wang, X.D.1
Masilamani, N.S.2
Mabrey, J.D.3
Alder, M.E.4
Agrawal, C.M.5
-
36
-
-
33744458766
-
Parameters affecting primary stability of orthodontic mini-implants
-
Wilmes B., Rademacher C., Olthoff G., and Drescher D. Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop 67 (2006) 162-174
-
(2006)
J Orofac Orthop
, vol.67
, pp. 162-174
-
-
Wilmes, B.1
Rademacher, C.2
Olthoff, G.3
Drescher, D.4
|