1
-
-
0032151752
-
Assessment of implant stability as a prognostic determinant
-
Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998;11: 491-501.
-
(1998)
Int J Prosthodont
, vol.11
, pp. 491-501
-
-
Meredith, N.1
-
2
-
-
44349141722
-
Initial stability measurement of dental implants placed in different anatomical regions of fresh human cadaver jawbone
-
Seong WJ, Holte JE, Holtan JR, Olin PS, Hodges JS, Ko CC. Initial stability measurement of dental implants placed in different anatomical regions of fresh human cadaver jawbone. J Prosthet Dent 2008;99: 425-434.
-
(2008)
J Prosthet Dent
, vol.99
, pp. 425-434
-
-
Seong, W.J.1
Holte, J.E.2
Holtan, J.R.3
Olin, P.S.4
Hodges, J.S.5
Ko, C.C.6
-
3
-
-
0032458301
-
A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants
-
Meredith N. A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants. Crit Rev Biomed Eng 1998;26: 275-291.
-
(1998)
Crit Rev Biomed Eng
, vol.26
, pp. 275-291
-
-
Meredith, N.1
-
4
-
-
33747064355
-
A numerical approach to resonance frequency analysis for the investigation of oral implant osseointegration
-
Natali AN, Pavan PG, Schileo E, Williams KR. A numerical approach to resonance frequency analysis for the investigation of oral implant osseointegration. J Oral Rehabil 2006;33: 674-681.
-
(2006)
J Oral Rehabil
, vol.33
, pp. 674-681
-
-
Natali, A.N.1
Pavan, P.G.2
Schileo, E.3
Williams, K.R.4
-
5
-
-
56349138585
-
A dynamic analytical model for impact evaluation of percutaneous implants
-
Swain R, Faulkner G, Raboud D, Wolfaardt J. A dynamic analytical model for impact evaluation of percutaneous implants. J Biomech Eng 2008;130: 051013.
-
(2008)
J Biomech Eng
, vol.130
, pp. 51013
-
-
Swain, R.1
Faulkner, G.2
Raboud, D.3
Wolfaardt, J.4
-
6
-
-
33748309280
-
Validity and clinical significance of biomechanical testing of implant/bone interface
-
Aparicio C, Lang NP, Rangert B. Validity and clinical significance of biomechanical testing of implant/bone interface. Clin Oral Implants Res 2006;17(suppl 2): 2-7.
-
(2006)
Clin Oral Implants Res
, vol.17
, pp. 2-7
-
-
Aparicio, C.1
Lang, N.P.2
Rangert, B.3
-
7
-
-
47249142397
-
Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: Comparison of both techniques in a clinical trial
-
Zix J, Hug S, Kessler-Liechti G, Mericske-Stern R. Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: Comparison of both techniques in a clinical trial. Int J Oral Maxillofac Implants 2008;23: 525-530.
-
(2008)
Int J Oral Maxillofac Implants
, vol.23
, pp. 525-530
-
-
Zix, J.1
Hug, S.2
Kessler-Liechti, G.3
Mericske-Stern, R.4
-
9
-
-
0026862876
-
Periotest for measuring periodontal characteristics-Correlation with periodontal bone loss
-
Schulte W, d’Hoedt B, Lukas D, Maunz M, Steppeler M. Periotest for measuring periodontal characteristics-Correlation with periodontal bone loss. J Periodontal Res 1992;27: 184-190.
-
(1992)
J Periodontal Res
, vol.27
, pp. 184-190
-
-
Schulte, W.1
d’Hoedt, B.2
Lukas, D.3
Maunz, M.4
Steppeler, M.5
-
10
-
-
0029265012
-
A method for assessing the damping characteristics of periodontal tissues: Goals and limitations
-
Rosenberg D, Quirynen M, van Steenberghe D, Naert IE, Tricio J, Nys M. A method for assessing the damping characteristics of periodontal tissues: Goals and limitations. Quintessence Int 1995;26: 191-197.
-
(1995)
Quintessence Int
, vol.26
, pp. 191-197
-
-
Rosenberg, D.1
Quirynen, M.2
van Steenberghe, D.3
Naert, I.E.4
Tricio, J.5
Nys, M.6
-
11
-
-
42149147336
-
Implant stability measurements using resonance frequency analysis: Biological and biomechanical aspects and clinical implications
-
Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: Biological and biomechanical aspects and clinical implications. Periodontol 2000 2008;47: 51-66.
-
(2008)
Periodontol 2000
, vol.47
, pp. 51-66
-
-
Sennerby, L.1
Meredith, N.2
-
12
-
-
37849013565
-
Parameters of resonance frequency measurement values: A retrospective study of 385 ITI dental implants
-
Karl M, Graef F, Heckmann S, Krafft T. Parameters of resonance frequency measurement values: A retrospective study of 385 ITI dental implants. Clin Oral Implants Res 2008;19: 214-218.
-
(2008)
Clin Oral Implants Res
, vol.19
, pp. 214-218
-
-
Karl, M.1
Graef, F.2
Heckmann, S.3
Krafft, T.4
-
13
-
-
66149084859
-
Influence of osseointegration degree and pattern on resonance frequency in the assessment of dental implant stability using finite element analysis
-
Deng B, Tan KB, Liu GR, Lu Y. Influence of osseointegration degree and pattern on resonance frequency in the assessment of dental implant stability using finite element analysis. Int J Oral Maxillofac Implants 2008;23: 1082-1088.
-
(2008)
Int J Oral Maxillofac Implants
, vol.23
, pp. 1082-1088
-
-
Deng, B.1
Tan, K.B.2
Liu, G.R.3
Lu, Y.4
-
14
-
-
32644436644
-
The resonance frequencies and mode shapes of dental implants: Rigid body behaviour versus bending behaviour. A numerical approach
-
Pattijn V, Van Lierde C, Van der Perre G, Naert I, Vander Sloten J. The resonance frequencies and mode shapes of dental implants: Rigid body behaviour versus bending behaviour. A numerical approach. J Biomech 2006;39: 939-947.
-
(2006)
J Biomech
, vol.39
, pp. 939-947
-
-
Pattijn, V.1
Van Lierde, C.2
Van der Perre, G.3
Naert, I.4
Vander Sloten, J.5
-
15
-
-
51149100968
-
Relationship between dental implant stability determined by resonance frequency analysis measurements and peri-implant vertical defects: An in vitro study
-
Tözüm TF, Turkyilmaz I, McGlumphy EA. Relationship between dental implant stability determined by resonance frequency analysis measurements and peri-implant vertical defects: An in vitro study. J Oral Rehabil 2008;35: 739-744.
-
(2008)
J Oral Rehabil
, vol.35
, pp. 739-744
-
-
Tözüm, T.F.1
Turkyilmaz, I.2
McGlumphy, E.A.3
-
16
-
-
7944232457
-
Implant stability measurement of delayed and immediately loaded implants during healing
-
Bischof M, Nedir R, Szmukler-Moncler S, Bernard JP, Samson J. Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res 2004;15: 529-539.
-
(2004)
Clin Oral Implants Res
, vol.15
, pp. 529-539
-
-
Bischof, M.1
Nedir, R.2
Szmukler-Moncler, S.3
Bernard, J.P.4
Samson, J.5
-
17
-
-
0036987398
-
Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: A pilot study
-
Balleri P, Cozzolino A, Ghelli L, Momicchioli G, Varriale A. Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: A pilot study. Clin Implant Dent Relat Res 2002;4: 128-132.
-
(2002)
Clin Implant Dent Relat Res
, vol.4
, pp. 128-132
-
-
Balleri, P.1
Cozzolino, A.2
Ghelli, L.3
Momicchioli, G.4
Varriale, A.5
-
18
-
-
32644446492
-
Resonance frequency analysis measurements of implants at placement surgery
-
Ostman PO, Hellman M, Wendelhag I, Sennerby L. Resonance frequency analysis measurements of implants at placement surgery. Int J Prosthodont 2006;19: 77-83.
-
(2006)
Int J Prosthodont
, vol.19
, pp. 77-83
-
-
Ostman, P.O.1
Hellman, M.2
Wendelhag, I.3
Sennerby, L.4
-
19
-
-
0029174071
-
Mechanical state assessment of the implant-bone continuum: A better understanding of the Periotest method
-
Tricio J, Laohapand P, van Steenberghe D, Quirynen M, Naert I. Mechanical state assessment of the implant-bone continuum: A better understanding of the Periotest method. Int J Oral Maxillofac Implants 1995;10: 43-49.
-
(1995)
Int J Oral Maxillofac Implants
, vol.10
, pp. 43-49
-
-
Tricio, J.1
Laohapand, P.2
van Steenberghe, D.3
Quirynen, M.4
Naert, I.5
-
20
-
-
0029264675
-
Damping characteristics of bone-to-implant interfaces. A clinical study with the Periotest device
-
Van Steenberghe D, Tricio J, Naert I, Nys M. Damping characteristics of bone-to-implant interfaces. A clinical study with the Periotest device. Clin Oral Implants Res 1995;6: 31-39.
-
(1995)
Clin Oral Implants Res
, vol.6
, pp. 31-39
-
-
Van Steenberghe, D.1
Tricio, J.2
Naert, I.3
Nys, M.4
-
21
-
-
0345304947
-
Implant stability and histomorphometry: A correlation study in human cadavers using stepped cylinder implants
-
Nkenke E, Hahn M, Weinzierl K, Radespiel-Tröger M, Neukam FW, Engelke K. Implant stability and histomorphometry: A correlation study in human cadavers using stepped cylinder implants. Clin Oral Implants Res 2003;14: 601-609.
-
(2003)
Clin Oral Implants Res
, vol.14
, pp. 601-609
-
-
Nkenke, E.1
Hahn, M.2
Weinzierl, K.3
Radespiel-Tröger, M.4
Neukam, F.W.5
Engelke, K.6
-
22
-
-
62849086385
-
A comparative study of two noninvasive techniques to evaluate implant stability: Periotest and Osstell Mentor
-
Oh JS, Kim SG, Lim SC, Ong JL. A comparative study of two noninvasive techniques to evaluate implant stability: Periotest and Osstell Mentor. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009;107: 513-518.
-
(2009)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.107
, pp. 513-518
-
-
Oh, J.S.1
Kim, S.G.2
Lim, S.C.3
Ong, J.L.4
-
23
-
-
33645084797
-
Resonance frequency analysis and damping capacity assessment. Part I: An in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability
-
Lachmann S, Jager B, Axmann D, Gomez-Roman G, Groten M, Weber H. Resonance frequency analysis and damping capacity assessment. Part I: An in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability. Clin Oral Implants Res 2006;17: 75-79.
-
(2006)
Clin Oral Implants Res
, vol.17
, pp. 75-79
-
-
Lachmann, S.1
Jager, B.2
Axmann, D.3
Gomez-Roman, G.4
Groten, M.5
Weber, H.6
-
24
-
-
33645051957
-
Resonance frequency analysis and damping capacity assessmen. Part 2: Peri-implant bone loss follow-up. An in vitro study with the Periotest and Osstell instruments
-
Lachmann S, Laval JY, Jager B, et al. Resonance frequency analysis and damping capacity assessmen. Part 2: Peri-implant bone loss follow-up. An in vitro study with the Periotest and Osstell instruments. Clin Oral Implants Res 2006;17: 80-84.
-
(2006)
Clin Oral Implants Res
, vol.17
, pp. 80-84
-
-
Lachmann, S.1
Laval, J.Y.2
Jager, B.3
-
25
-
-
70349264121
-
Biomechanical methods applied in dentistry: A comparative overview of photoelastic examinations, strain gauge measurements, finite element analysis and three-dimensional deformation analysis
-
Karl M, Dickinson A, Holst S, Holst A. Biomechanical methods applied in dentistry: A comparative overview of photoelastic examinations, strain gauge measurements, finite element analysis and three-dimensional deformation analysis. Eur J Prosthodont Restorative Dent 2009;17: 50-57.
-
(2009)
Eur J Prosthodont Restorative Dent
, vol.17
, pp. 50-57
-
-
Karl, M.1
Dickinson, A.2
Holst, S.3
Holst, A.4
-
26
-
-
0031240099
-
Investigation of the integration process of dental implants by means of a numerical analysis of dynamic response
-
Natali AN, Meroi EA, Williams KR, Calabrese L. Investigation of the integration process of dental implants by means of a numerical analysis of dynamic response. Dent Mater 1997;13: 325-332.
-
(1997)
Dent Mater
, vol.13
, pp. 325-332
-
-
Natali, A.N.1
Meroi, E.A.2
Williams, K.R.3
Calabrese, L.4
-
27
-
-
34447506068
-
A three-dimensional finite element study on the biomechanical behavior of an FGBM dental implant in surrounding bone
-
Yang J, Xiang HJ. A three-dimensional finite element study on the biomechanical behavior of an FGBM dental implant in surrounding bone. J Biomech 2007;40: 2377-2385.
-
(2007)
J Biomech
, vol.40
, pp. 2377-2385
-
-
Yang, J.1
Xiang, H.J.2
-
28
-
-
7444222504
-
A time depending healing function for immediate loaded implants
-
Winter W, Heckmann SM, Weber HP. A time depending healing function for immediate loaded implants. J Biomech 2004;37: 1861-1867.
-
(2004)
J Biomech
, vol.37
, pp. 1861-1867
-
-
Winter, W.1
Heckmann, S.M.2
Weber, H.P.3
-
29
-
-
85009195610
-
Mechanical properties of cortical bone and cancellous bone tissue
-
Cowin SC (ed), Boca Raton, FL: CRC
-
Guo XE. Mechanical properties of cortical bone and cancellous bone tissue. In: Cowin SC (ed). Bone Mechanics Handbook. Boca Raton, FL: CRC, 2001: 1001-1023.
-
(2001)
Bone Mechanics Handbook
, pp. 1001-1023
-
-
Guo, X.E.1
-
33
-
-
70249105029
-
Correlating implant stability to bone structure
-
Rozé J, Babu S, Saffarzadeh A, Gayet-Delacroix M, Hoornaert A, Layrolle P. Correlating implant stability to bone structure. Clin Oral Implants Res 2009;20: 1140-1145.
-
(2009)
Clin Oral Implants Res
, vol.20
, pp. 1140-1145
-
-
Rozé, J.1
Babu, S.2
Saffarzadeh, A.3
Gayet-Delacroix, M.4
Hoornaert, A.5
Layrolle, P.6
-
34
-
-
67649173038
-
Correlation between bone quality evaluated by cone-beam computerized tomography and implant primary stability
-
Song YD, Jun SH, Kwon JJ. Correlation between bone quality evaluated by cone-beam computerized tomography and implant primary stability. Int J Oral Maxillofac Implants 2009;24: 59-64.
-
(2009)
Int J Oral Maxillofac Implants
, vol.24
, pp. 59-64
-
-
Song, Y.D.1
Jun, S.H.2
Kwon, J.J.3
-
35
-
-
7944234226
-
Predicting osseointegration by means of implant primary stability
-
Nedir R, Bischof M, Szmukler-Moncler S, Bernard JP, Samson J. Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res 2004;15: 520-528.
-
(2004)
Clin Oral Implants Res
, vol.15
, pp. 520-528
-
-
Nedir, R.1
Bischof, M.2
Szmukler-Moncler, S.3
Bernard, J.P.4
Samson, J.5
-
36
-
-
34247471672
-
Different bone loading patterns due to fixation of three-unit and five-unit implant prostheses
-
Karl M, Winter W, Dickinson AJ, Wichmann MG, Heckmann SM. Different bone loading patterns due to fixation of three-unit and five-unit implant prostheses. Aust Dent J 2007;52: 47-54.
-
(2007)
Aust Dent J
, vol.52
, pp. 47-54
-
-
Karl, M.1
Winter, W.2
Dickinson, A.J.3
Wichmann, M.G.4
Heckmann, S.M.5
-
37
-
-
0034218915
-
Mechanics of the implantabutment connection: An 8-degree taper compared to a butt joint connection
-
Merz BR, Hunenbart S, Belser UC. Mechanics of the implantabutment connection: An 8-degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants 2000;15: 519-526.
-
(2000)
Int J Oral Maxillofac Implants
, vol.15
, pp. 519-526
-
-
Merz, B.R.1
Hunenbart, S.2
Belser, U.C.3
|