Volumn 31, Issue 7, 2009, Pages 764-769

Influence of the orientation of the Osstell® transducer during measurement of dental implant stability using resonance frequency analysis: A numerical approach

Author keywords

Dental implants; Eigenfrequency; Finite element analysis; Resonance frequency; Resonance frequency analysis; Stability

Indexed keywords

DENTAL IMPLANTS; EIGENFREQUENCY; FINITE ELEMENT ANALYSIS; RESONANCE FREQUENCY; RESONANCE FREQUENCY ANALYSIS;

EID: 68349122619     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2009.02.003     Document Type: Article
Times cited : (22)

References (28)
  • 1
    • 0031152150 scopus 로고    scopus 로고
    • Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla
    • Meredith N., Book K., Friberg B., Jemt T., and Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Impl Res 8 (1997) 226-233
    • (1997) Clin Oral Impl Res , vol.8 , pp. 226-233
    • Meredith, N.1    Book, K.2    Friberg, B.3    Jemt, T.4    Sennerby, L.5
  • 2
    • 33847790159 scopus 로고    scopus 로고
    • Evaluation of two different resonance frequency devices to detect implant stability: a clinical trial
    • Valderrama P., Oates T.W., Jones A.A., Simpson J., Schoolfield J.D., and Cochran D.L. Evaluation of two different resonance frequency devices to detect implant stability: a clinical trial. J Periodontol 78 (2007) 262-272
    • (2007) J Periodontol , vol.78 , pp. 262-272
    • Valderrama, P.1    Oates, T.W.2    Jones, A.A.3    Simpson, J.4    Schoolfield, J.D.5    Cochran, D.L.6
  • 3
    • 34547217298 scopus 로고    scopus 로고
    • Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation
    • Huwiler M.A., Pjetursson B.E., Bosshardt D.D., Salvi G.E., and Lang N.P. Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation. Clin Oral Impl Res 18 (2007) 275-280
    • (2007) Clin Oral Impl Res , vol.18 , pp. 275-280
    • Huwiler, M.A.1    Pjetursson, B.E.2    Bosshardt, D.D.3    Salvi, G.E.4    Lang, N.P.5
  • 4
    • 34748907222 scopus 로고    scopus 로고
    • Analysis of the potential association of implant stability, laboratory, and image-based measures used to assess osteotomy sites: early versus delayed loading
    • Tozum T.F., Turkyilmaz I., Yamalik N., Karabulut E., and Eratalay K. Analysis of the potential association of implant stability, laboratory, and image-based measures used to assess osteotomy sites: early versus delayed loading. J Periodontol 78 (2007) 1675-1682
    • (2007) J Periodontol , vol.78 , pp. 1675-1682
    • Tozum, T.F.1    Turkyilmaz, I.2    Yamalik, N.3    Karabulut, E.4    Eratalay, K.5
  • 5
    • 0030068851 scopus 로고    scopus 로고
    • In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysis
    • Perre G., and Lowet G. In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysis. Bone 18 (1996) 29S-35S
    • (1996) Bone , vol.18
    • Perre, G.1    Lowet, G.2
  • 6
    • 0030221980 scopus 로고    scopus 로고
    • The relation between resonant frequencies and torsional stiffness of long bones in vitro
    • Lowet G. The relation between resonant frequencies and torsional stiffness of long bones in vitro. J Biomech 29 (1996) 1003-1010
    • (1996) J Biomech , vol.29 , pp. 1003-1010
    • Lowet, G.1
  • 8
    • 32644436644 scopus 로고    scopus 로고
    • The resonance frequencies and mode shapes of dental implants: rigid body behaviour versus bending behaviour. A numerical approach
    • Pattijn V., Lierde C., Perre G., Naert I., and Sloten J. The resonance frequencies and mode shapes of dental implants: rigid body behaviour versus bending behaviour. A numerical approach. J Biomech 39 (2006) 939-947
    • (2006) J Biomech , vol.39 , pp. 939-947
    • Pattijn, V.1    Lierde, C.2    Perre, G.3    Naert, I.4    Sloten, J.5
  • 9
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
    • Meredith N., Allene D., and Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Impl Res 7 (1996) 261-267
    • (1996) Clin Oral Impl Res , vol.7 , pp. 261-267
    • Meredith, N.1    Allene, D.2    Cawley, P.3
  • 10
    • 68349100692 scopus 로고    scopus 로고
    • Osstell™ user's manual. Integration Diagnostics AB, Göteborg.
    • Osstell™ user's manual. Integration Diagnostics AB, Göteborg.
  • 11
    • 68349095690 scopus 로고    scopus 로고
    • Osstell™ Mentor user's manuals. Integration Diagnostics AB, Göteborg.
    • Osstell™ Mentor user's manuals. Integration Diagnostics AB, Göteborg.
  • 13
  • 14
    • 11844280921 scopus 로고    scopus 로고
    • Monitoring of implant stability in grafted bone using resonance frequency analysis. A clinical study from placement to 6 months of loading
    • Sjo{combining double acute accent}stro{combining double acute accent}m M., Lundgren S., Nilson H., and Sennerby L. Monitoring of implant stability in grafted bone using resonance frequency analysis. A clinical study from placement to 6 months of loading. Oral Maxillofac Surg 34 (2004) 45-51
    • (2004) Oral Maxillofac Surg , vol.34 , pp. 45-51
    • Sjostrom, M.1    Lundgren, S.2    Nilson, H.3    Sennerby, L.4
  • 15
    • 33645084797 scopus 로고    scopus 로고
    • Resonance frequency analysis and damping capacity assessment. Part I: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability
    • Lachmann S., Jäger B., Axmann D., Gomez-Roman G., Groten M., and Weber H. Resonance frequency analysis and damping capacity assessment. Part I: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability. Clin Oral Impl Res 17 (2006) 75-79
    • (2006) Clin Oral Impl Res , vol.17 , pp. 75-79
    • Lachmann, S.1    Jäger, B.2    Axmann, D.3    Gomez-Roman, G.4    Groten, M.5    Weber, H.6
  • 16
    • 33645051957 scopus 로고    scopus 로고
    • Resonance frequency analysis and damping capacity assessment. Part II: peri-implant bone loss follow-up. An in vitro study with Periotest and Osstell instruments
    • Lachmann S., Laval J.Y., Jäger B., Axmann D., Gomez-Roman G., Groten M., and Weber H. Resonance frequency analysis and damping capacity assessment. Part II: peri-implant bone loss follow-up. An in vitro study with Periotest and Osstell instruments. Clin Oral Impl Res 17 (2006) 80-84
    • (2006) Clin Oral Impl Res , vol.17 , pp. 80-84
    • Lachmann, S.1    Laval, J.Y.2    Jäger, B.3    Axmann, D.4    Gomez-Roman, G.5    Groten, M.6    Weber, H.7
  • 18
    • 37249059880 scopus 로고    scopus 로고
    • Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model
    • Al-Nawas B., Groetz K.A., Goetz H., Duschner H., and Wagner W. Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model. Clin Oral Impl Res 19 (2008) 1-8
    • (2008) Clin Oral Impl Res , vol.19 , pp. 1-8
    • Al-Nawas, B.1    Groetz, K.A.2    Goetz, H.3    Duschner, H.4    Wagner, W.5
  • 19
    • 34548094603 scopus 로고    scopus 로고
    • Evaluation of factors influencing resonance frequency analysis values, at insertion surgery, of implants placed in sinus-augmented and nongrafted sites
    • Degidi M., Daprile G., Piattelli A., and Carinci F. Evaluation of factors influencing resonance frequency analysis values, at insertion surgery, of implants placed in sinus-augmented and nongrafted sites. Clin Impl Dent Relat Res 9 (2007) 144-149
    • (2007) Clin Impl Dent Relat Res , vol.9 , pp. 144-149
    • Degidi, M.1    Daprile, G.2    Piattelli, A.3    Carinci, F.4
  • 20
    • 36049049424 scopus 로고    scopus 로고
    • Roles of bone scintigraphy and resonance frequency analysis in evaluating osseointegration of endosseous implant
    • Zhou Y., Jiang T., and Qian M. Roles of bone scintigraphy and resonance frequency analysis in evaluating osseointegration of endosseous implant. Biomaterials 29 (2008) 461-474
    • (2008) Biomaterials , vol.29 , pp. 461-474
    • Zhou, Y.1    Jiang, T.2    Qian, M.3
  • 21
    • 42149147336 scopus 로고    scopus 로고
    • Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications
    • Sennerby L., and Meredith N. Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontology 2008 47 (2000) 51-66
    • (2000) Periodontology , vol.2008 , Issue.47 , pp. 51-66
    • Sennerby, L.1    Meredith, N.2
  • 22
    • 33748309280 scopus 로고    scopus 로고
    • Validity and clinical significance of biomechanical testing of implant/bone interface
    • Aparicio C., Lang N.P., and Rangert B. Validity and clinical significance of biomechanical testing of implant/bone interface. Clin Oral Impl Res 17 Suppl 2 (2006) 2-7
    • (2006) Clin Oral Impl Res , vol.17 , Issue.SUPPL. 2 , pp. 2-7
    • Aparicio, C.1    Lang, N.P.2    Rangert, B.3
  • 23
    • 33947110495 scopus 로고    scopus 로고
    • Influence of transducer orientation on Osstell™ stability measurements of osseointegrated implants
    • Veltri M., Balleri P., and Ferrari M. Influence of transducer orientation on Osstell™ stability measurements of osseointegrated implants. Clin Impl Dent Rel Res 9 (2007) 60-63
    • (2007) Clin Impl Dent Rel Res , vol.9 , pp. 60-63
    • Veltri, M.1    Balleri, P.2    Ferrari, M.3
  • 25
    • 37249055018 scopus 로고    scopus 로고
    • Relevance of resonance frequency analysis to evaluate dental implant stability: simulation and histomorphometrical animal experiments
    • Ito Y., Sato D., Yoneda S., Ito D., Kondo H., and Kasugai S. Relevance of resonance frequency analysis to evaluate dental implant stability: simulation and histomorphometrical animal experiments. Clin Oral Impl Res 19 (2008) 9-14
    • (2008) Clin Oral Impl Res , vol.19 , pp. 9-14
    • Ito, Y.1    Sato, D.2    Yoneda, S.3    Ito, D.4    Kondo, H.5    Kasugai, S.6
  • 26
    • 34547700240 scopus 로고    scopus 로고
    • Clinical study on the primary stability of two dental implant systems with resonance frequency analysis
    • Rabel A., Köhler S.G., and Schmidt-Westhausen A.M. Clinical study on the primary stability of two dental implant systems with resonance frequency analysis. Clin Oral Investig 11 (2007) 257-265
    • (2007) Clin Oral Investig , vol.11 , pp. 257-265
    • Rabel, A.1    Köhler, S.G.2    Schmidt-Westhausen, A.M.3
  • 27
    • 28844480575 scopus 로고    scopus 로고
    • Influence of cortical bone thickness and implant length on implant stability at the time of surgery-clinical, prospective, biomechanical, and imaging study
    • Miyamoto I., Tsuboi Y., Wada E., Suwa H., and Iizuka T. Influence of cortical bone thickness and implant length on implant stability at the time of surgery-clinical, prospective, biomechanical, and imaging study. Bone 37 (2005) 776-780
    • (2005) Bone , vol.37 , pp. 776-780
    • Miyamoto, I.1    Tsuboi, Y.2    Wada, E.3    Suwa, H.4    Iizuka, T.5
  • 28
    • 0031152189 scopus 로고    scopus 로고
    • The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia
    • Meredith N., Shagaldi F., Alleyne D., Sennerby L., and Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Impl Res 8 (1997) 234-243
    • (1997) Clin Oral Impl Res , vol.8 , pp. 234-243
    • Meredith, N.1    Shagaldi, F.2    Alleyne, D.3    Sennerby, L.4    Cawley, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.