메뉴 건너뛰기




Volumn 28, Issue 6, 2015, Pages 665-676

Hypothermic machine perfusion of kidneys retrieved from standard and high-risk donors

Author keywords

delayed graft function; donation after brain death; donation after circulatory death; expanded criteria donors; extended criteria donors; graft quality; history of machine perfusion; hypothermic machine perfusion; kidney transplantation; organ preservation; perfusate biomarkers; renal resistance; viability assessment

Indexed keywords

BIOLOGICAL MARKER; OXYGEN; PRESERVATION SOLUTION;

EID: 84929511432     PISSN: 09340874     EISSN: 14322277     Source Type: Journal    
DOI: 10.1111/tri.12530     Document Type: Review
Times cited : (67)

References (117)
  • 1
    • 84990540147 scopus 로고
    • An apparatus for the culture of whole organs
    • Lindbergh CA,. An apparatus for the culture of whole organs. J Exp Med 1935; 62: 409.
    • (1935) J Exp Med , vol.62 , pp. 409
    • Lindbergh, C.A.1
  • 2
    • 0345416450 scopus 로고
    • Factors influencing renal blood flow during isolated perfusion
    • Belzer FO, Park HY, Vetto RM,. Factors influencing renal blood flow during isolated perfusion. Surg Forum 1964; 15: 222.
    • (1964) Surg Forum , vol.15 , pp. 222
    • Belzer, F.O.1    Park, H.Y.2    Vetto, R.M.3
  • 3
    • 0014197055 scopus 로고
    • 24-hour and 72-hour preservation of canine kidneys
    • Belzer FO, Ashby BS, Dunphy JE,. 24-hour and 72-hour preservation of canine kidneys. Lancet 1967; 2: 536.
    • (1967) Lancet , vol.2 , pp. 536
    • Belzer, F.O.1    Ashby, B.S.2    Dunphy, J.E.3
  • 4
    • 0014333296 scopus 로고
    • Etiology of rising perfusion pressure in isolated organ perfusion
    • Belzer FO, Ashby BS, Huang JS, Dunphy JE,. Etiology of rising perfusion pressure in isolated organ perfusion. Ann Surg 1968; 168: 382.
    • (1968) Ann Surg , vol.168 , pp. 382
    • Belzer, F.O.1    Ashby, B.S.2    Huang, J.S.3    Dunphy, J.E.4
  • 5
    • 0014413440 scopus 로고
    • Successful seventeen-hour preservation and transplantation of human-cadaver kidney
    • Belzer FO, Ashby BS, Gulyassy PF, Powell M,. Successful seventeen-hour preservation and transplantation of human-cadaver kidney. N Engl J Med 1968; 278: 608.
    • (1968) N Engl J Med , vol.278 , pp. 608
    • Belzer, F.O.1    Ashby, B.S.2    Gulyassy, P.F.3    Powell, M.4
  • 6
    • 84902892415 scopus 로고
    • Organ Preservation: A personal perspective
    • Terasaki P.I. ed. Los Angeles, CA: UCLA Tissue Typing Laboratory
    • Belzer FO,. Organ Preservation: a personal perspective. In:, Terasaki PI, ed. History of Transplantation: Thirty-Five Recollection. Los Angeles, CA: UCLA Tissue Typing Laboratory, 1991: 597-613.
    • (1991) History of Transplantation: Thirty-Five Recollection , pp. 597-613
    • Belzer, F.O.1
  • 7
    • 0014666307 scopus 로고
    • Kidney preservation for transportation. Initial perfusion and 30 hours' ice storage
    • Collins GM, Bravo-Shugarman M, Terasaki PI,. Kidney preservation for transportation. Initial perfusion and 30 hours' ice storage. Lancet 1969; 2: 1219.
    • (1969) Lancet , vol.2 , pp. 1219
    • Collins, G.M.1    Bravo-Shugarman, M.2    Terasaki, P.I.3
  • 8
    • 0015032863 scopus 로고
    • Successful 24-hour kidney preservation with simplified hyperosmolar hyperkalemic perfusate
    • Watkins GM, Prentiss NA, Couch NP,. Successful 24-hour kidney preservation with simplified hyperosmolar hyperkalemic perfusate. Transplant Proc 1971; 3: 612.
    • (1971) Transplant Proc , vol.3 , pp. 612
    • Watkins, G.M.1    Prentiss, N.A.2    Couch, N.P.3
  • 9
    • 0014403727 scopus 로고
    • A definition of irreversible coma. Report of the Ad Hoc Committee of the Harvard Medical School to examine the definition of brain death
    • Beecher H,. A definition of irreversible coma. Report of the Ad Hoc Committee of the Harvard Medical School to examine the definition of brain death. JAMA 1968; 205: 337.
    • (1968) JAMA , vol.205 , pp. 337
    • Beecher, H.1
  • 10
    • 0018526730 scopus 로고
    • Status of the legal definition of death
    • Selby R, Selby MT,. Status of the legal definition of death. Neurosurgery 1979; 5: 535.
    • (1979) Neurosurgery , vol.5 , pp. 535
    • Selby, R.1    Selby, M.T.2
  • 11
    • 0020594242 scopus 로고
    • Synthetic perfusate for kidney preservation. Its use in 72-hour preservation of dog kidneys
    • Hoffmann RM, Southard JH, Lutz M, Mackety A, Belzer FO,. Synthetic perfusate for kidney preservation. Its use in 72-hour preservation of dog kidneys. Arch Surg 1983; 118: 919.
    • (1983) Arch Surg , vol.118 , pp. 919
    • Hoffmann, R.M.1    Southard, J.H.2    Lutz, M.3    Mackety, A.4    Belzer, F.O.5
  • 14
    • 0035077657 scopus 로고    scopus 로고
    • Preservation of non-heart-beating donor kidneys: A clinical prospective randomised case-control study of machine perfusion versus cold storage
    • van der Vliet JA, Kievit JK, Hene RJ, Hilbrands LB, Kootstra G,. Preservation of non-heart-beating donor kidneys: a clinical prospective randomised case-control study of machine perfusion versus cold storage. Transplant Proc 2001; 33: 847.
    • (2001) Transplant Proc , vol.33 , pp. 847
    • Van Der Vliet, J.A.1    Kievit, J.K.2    Hene, R.J.3    Hilbrands, L.B.4    Kootstra, G.5
  • 15
    • 0033033122 scopus 로고    scopus 로고
    • Rejection rate and incidence of acute tubular necrosis after pulsatile perfusion preservation
    • Kosieradzki M, Danielewicz R, Kwiatkowski A, et al,. Rejection rate and incidence of acute tubular necrosis after pulsatile perfusion preservation. Transplant Proc 1999; 31: 278.
    • (1999) Transplant Proc , vol.31 , pp. 278
    • Kosieradzki, M.1    Danielewicz, R.2    Kwiatkowski, A.3
  • 16
    • 0031472879 scopus 로고    scopus 로고
    • Comparison of static versus pulsatile preservation of matched-paired kidneys
    • Gage F, Ali M, Alijani MR, et al,. Comparison of static versus pulsatile preservation of matched-paired kidneys. Transplant Proc 1997; 29: 3644.
    • (1997) Transplant Proc , vol.29 , pp. 3644
    • Gage, F.1    Ali, M.2    Alijani, M.R.3
  • 17
    • 0028353295 scopus 로고
    • Renal allograft preservation: A comparison of University of Wisconsin solution and of hypothermic continuous pulsatile perfusion
    • Veller MG, Botha JR, Britz RS, et al,. Renal allograft preservation: a comparison of University of Wisconsin solution and of hypothermic continuous pulsatile perfusion. Clin Transplant 1994; 8: 97.
    • (1994) Clin Transplant , vol.8 , pp. 97
    • Veller, M.G.1    Botha, J.R.2    Britz, R.S.3
  • 18
    • 0028118910 scopus 로고
    • The effect of machine perfusion preservation versus cold storage on the function of kidneys from non-heart-beating donors
    • Matsuno N, Sakurai E, Tamaki I, Uchiyama M, Kozaki K, Kozaki M,. The effect of machine perfusion preservation versus cold storage on the function of kidneys from non-heart-beating donors. Transplantation 1994; 57: 293.
    • (1994) Transplantation , vol.57 , pp. 293
    • Matsuno, N.1    Sakurai, E.2    Tamaki, I.3    Uchiyama, M.4    Kozaki, K.5    Kozaki, M.6
  • 19
    • 0027411883 scopus 로고
    • Effect of combination in situ cooling and machine perfusion preservation on non-heart-beating donor kidney procurement
    • Matsuno N, Kozaki M, Sakurai E, et al,. Effect of combination in situ cooling and machine perfusion preservation on non-heart-beating donor kidney procurement. Transplant Proc 1993; 25: 1516.
    • (1993) Transplant Proc , vol.25 , pp. 1516
    • Matsuno, N.1    Kozaki, M.2    Sakurai, E.3
  • 20
  • 21
    • 0025108145 scopus 로고
    • A prospective controlled trial of cold-storage versus machine-perfusion preservation in cadaveric renal transplantation
    • Merion RM, Oh HK, Port FK, Toledo-Pereyra LH, Turcotte JG,. A prospective controlled trial of cold-storage versus machine-perfusion preservation in cadaveric renal transplantation. Transplantation 1990; 50: 230.
    • (1990) Transplantation , vol.50 , pp. 230
    • Merion, R.M.1    Oh, H.K.2    Port, F.K.3    Toledo-Pereyra, L.H.4    Turcotte, J.G.5
  • 22
    • 0024506850 scopus 로고
    • The absence of a deleterious effect of mechanical kidney preservation in the era of cyclosporine
    • Jaffers GJ, Banowsky LH,. The absence of a deleterious effect of mechanical kidney preservation in the era of cyclosporine. Transplantation 1989; 47: 734.
    • (1989) Transplantation , vol.47 , pp. 734
    • Jaffers, G.J.1    Banowsky, L.H.2
  • 23
    • 0023294572 scopus 로고
    • Preservation effect on oligo-anuria in the cyclosporine era: A prospective trial with 26 paired cadaveric renal allografts
    • Mendez R, Mendez RG, Koussa N, Cats S, Bogaard TP, Khetan U,. Preservation effect on oligo-anuria in the cyclosporine era: a prospective trial with 26 paired cadaveric renal allografts. Transplant Proc 1987; 19: 2047.
    • (1987) Transplant Proc , vol.19 , pp. 2047
    • Mendez, R.1    Mendez, R.G.2    Koussa, N.3    Cats, S.4    Bogaard, T.P.5    Khetan, U.6
  • 24
    • 0023221532 scopus 로고
    • A randomized prospective trial of cold storage versus pulsatile perfusion for cadaver kidney preservation
    • Halloran P, Aprile M,. A randomized prospective trial of cold storage versus pulsatile perfusion for cadaver kidney preservation. Transplantation 1987; 43: 827.
    • (1987) Transplantation , vol.43 , pp. 827
    • Halloran, P.1    Aprile, M.2
  • 26
    • 0022412309 scopus 로고
    • Single-donor cold storage versus machine perfusion in cadaver kidney preservation
    • Alijani MR, Cutler JA, DelValle CJ, et al,. Single-donor cold storage versus machine perfusion in cadaver kidney preservation. Transplantation 1985; 40: 659.
    • (1985) Transplantation , vol.40 , pp. 659
    • Alijani, M.R.1    Cutler, J.A.2    Delvalle, C.J.3
  • 27
    • 0018967087 scopus 로고
    • Renal preservation prior to transplantation
    • Marshall VC,. Renal preservation prior to transplantation. Transplantation 1980; 30: 165.
    • (1980) Transplantation , vol.30 , pp. 165
    • Marshall, V.C.1
  • 28
    • 0020800733 scopus 로고
    • Renal hypothermic storage with a new hyperosmolar colloid solution
    • Toledo-Pereyra LH,. Renal hypothermic storage with a new hyperosmolar colloid solution. Bol Asoc Med P R 1983; 75: 347.
    • (1983) Bol Asoc Med P R , vol.75 , pp. 347
    • Toledo-Pereyra, L.H.1
  • 29
    • 0018426811 scopus 로고
    • Machine versus cold storage preservation and TAN versus the energy charge as a predictor of graft function posttransplantation
    • Beck TA,. Machine versus cold storage preservation and TAN versus the energy charge as a predictor of graft function posttransplantation. Transplant Proc 1979; 11: 459.
    • (1979) Transplant Proc , vol.11 , pp. 459
    • Beck, T.A.1
  • 31
    • 0017763431 scopus 로고
    • Problems in clinical organ preservation
    • Marshall VC,. Problems in clinical organ preservation. Med J Aust 1977; 2: 361.
    • (1977) Med J Aust , vol.2 , pp. 361
    • Marshall, V.C.1
  • 32
    • 0015161925 scopus 로고
    • A comparison of hypothermic preservation with hypothermic pulsatile perfusion in paired human kidneys
    • Sterling WA, Pierce JC, Hutcher NE, Lee HM, Hume DM,. A comparison of hypothermic preservation with hypothermic pulsatile perfusion in paired human kidneys. Surg Forum 1971; 22: 229.
    • (1971) Surg Forum , vol.22 , pp. 229
    • Sterling, W.A.1    Pierce, J.C.2    Hutcher, N.E.3    Lee, H.M.4    Hume, D.M.5
  • 33
    • 85045797781 scopus 로고    scopus 로고
    • The clinical and cost-effectiveness of pulsatile machine perfusion versus cold storage of kidneys for transplantation retrieved from heart-beating and non-heart-beating donors
    • Wight J, Chilcott J, Holmes M, Brewer N,. The clinical and cost-effectiveness of pulsatile machine perfusion versus cold storage of kidneys for transplantation retrieved from heart-beating and non-heart-beating donors. Health Technol Assess 2003; 7: 1.
    • (2003) Health Technol Assess , vol.7 , pp. 1
    • Wight, J.1    Chilcott, J.2    Holmes, M.3    Brewer, N.4
  • 34
    • 0042121432 scopus 로고    scopus 로고
    • Pulsatile machine perfusion vs. Cold storage of kidneys for transplantation: A rapid and systematic review
    • Wight JP, Chilcott JB, Holmes MW, Brewer N,. Pulsatile machine perfusion vs. cold storage of kidneys for transplantation: a rapid and systematic review. Clin Transplant 2003; 17: 293.
    • (2003) Clin Transplant , vol.17 , pp. 293
    • Wight, J.P.1    Chilcott, J.B.2    Holmes, M.W.3    Brewer, N.4
  • 35
    • 58249089430 scopus 로고    scopus 로고
    • Machine perfusion or cold storage in deceased-donor kidney transplantation
    • Moers C, Smits JM, Maathuis MH, et al,. Machine perfusion or cold storage in deceased-donor kidney transplantation. N Engl J Med 2009; 360: 7.
    • (2009) N Engl J Med , vol.360 , pp. 7
    • Moers, C.1    Smits, J.M.2    Maathuis, M.H.3
  • 37
    • 84857424125 scopus 로고    scopus 로고
    • Machine perfusion or cold storage in deceased-donor kidney transplantation
    • Moers C, Pirenne J, Paul A, Ploeg RJ,. Machine perfusion or cold storage in deceased-donor kidney transplantation. N Engl J Med 2012; 366: 770.
    • (2012) N Engl J Med , vol.366 , pp. 770
    • Moers, C.1    Pirenne, J.2    Paul, A.3    Ploeg, R.J.4
  • 39
    • 0034719486 scopus 로고    scopus 로고
    • The influence of pulsatile preservation on renal transplantation in the 1990s
    • Polyak MM, Arrington BO, Stubenbord WT, et al,. The influence of pulsatile preservation on renal transplantation in the 1990s. Transplantation 2000; 69: 249.
    • (2000) Transplantation , vol.69 , pp. 249
    • Polyak, M.M.1    Arrington, B.O.2    Stubenbord, W.T.3
  • 40
    • 79955569761 scopus 로고    scopus 로고
    • Machine perfusion versus cold storage for preservation of kidneys from expanded criteria donors after brain death
    • Treckmann J, Moers C, Smits JM, et al,. Machine perfusion versus cold storage for preservation of kidneys from expanded criteria donors after brain death. Transpl Int 2011; 24: 548.
    • (2011) Transpl Int , vol.24 , pp. 548
    • Treckmann, J.1    Moers, C.2    Smits, J.M.3
  • 41
    • 49649101853 scopus 로고    scopus 로고
    • Impact of pulsatile perfusion on postoperative outcome of kidneys from controlled donors after cardiac death
    • Plata-Munoz JJ, Muthusamy A, Quiroga I, et al,. Impact of pulsatile perfusion on postoperative outcome of kidneys from controlled donors after cardiac death. Transpl Int 2008; 21: 899.
    • (2008) Transpl Int , vol.21 , pp. 899
    • Plata-Munoz, J.J.1    Muthusamy, A.2    Quiroga, I.3
  • 42
    • 34250187708 scopus 로고    scopus 로고
    • The influence of pulsatile preservation in kidney transplantation from non-heart-beating donors
    • Moustafellos P, Hadjianastassiou V, Roy D, et al,. The influence of pulsatile preservation in kidney transplantation from non-heart-beating donors. Transplant Proc 2007; 39: 1323.
    • (2007) Transplant Proc , vol.39 , pp. 1323
    • Moustafellos, P.1    Hadjianastassiou, V.2    Roy, D.3
  • 43
    • 0037116827 scopus 로고    scopus 로고
    • Liver and kidney preservation by perfusion
    • St Peter SD, Imber CJ, Friend PJ,. Liver and kidney preservation by perfusion. Lancet 2002; 359: 604.
    • (2002) Lancet , vol.359 , pp. 604
    • St Peter, S.D.1    Imber, C.J.2    Friend, P.J.3
  • 44
    • 0020034364 scopus 로고
    • Advantage of cold storage over machine perfusion for preservation of cadaver kidneys
    • Opelz G, Terasaki PI,. Advantage of cold storage over machine perfusion for preservation of cadaver kidneys. Transplantation 1982; 33: 64.
    • (1982) Transplantation , vol.33 , pp. 64
    • Opelz, G.1    Terasaki, P.I.2
  • 45
    • 78349293444 scopus 로고    scopus 로고
    • Machine perfusion versus cold storage for the preservation of kidneys donated after cardiac death: A multicenter randomized controlled trial
    • Jochmans I, Moers C, Smits JM, et al,. Machine perfusion versus cold storage for the preservation of kidneys donated after cardiac death: a multicenter randomized controlled trial. Ann Surg 2010; 252: 756.
    • (2010) Ann Surg , vol.252 , pp. 756
    • Jochmans, I.1    Moers, C.2    Smits, J.M.3
  • 46
  • 47
    • 0037378524 scopus 로고    scopus 로고
    • Nonheart-beating kidney donation: Current practice and future developments
    • Brook NR, Waller JR, Nicholson ML,. Nonheart-beating kidney donation: current practice and future developments. Kidney Int 2003; 63: 1516.
    • (2003) Kidney Int , vol.63 , pp. 1516
    • Brook, N.R.1    Waller, J.R.2    Nicholson, M.L.3
  • 48
    • 33847292784 scopus 로고    scopus 로고
    • Non-heartbeating donation of kidneys for transplantation
    • Kootstra G, van Heurn E,. Non-heartbeating donation of kidneys for transplantation. Nat Clin Pract Nephrol 2007; 3: 154.
    • (2007) Nat Clin Pract Nephrol , vol.3 , pp. 154
    • Kootstra, G.1    Van Heurn, E.2
  • 49
    • 77956165611 scopus 로고    scopus 로고
    • Cold machine perfusion versus static cold storage of kidneys donated after cardiac death: A UK multicenter randomized controlled trial
    • Watson CJE, Wells AC, Roberts RJ, et al,. Cold machine perfusion versus static cold storage of kidneys donated after cardiac death: a UK multicenter randomized controlled trial. Am J Transplant 2010; 10: 1991.
    • (2010) Am J Transplant , vol.10 , pp. 1991
    • Watson, C.J.E.1    Wells, A.C.2    Roberts, R.J.3
  • 50
    • 84873719300 scopus 로고    scopus 로고
    • Hypothermic machine perfusion in deceased donor kidney transplantation: A systematic review
    • Lam VW, Laurence JM, Richardson AJ, Pleass HC, Allen RD,. Hypothermic machine perfusion in deceased donor kidney transplantation: a systematic review. J Surg Res 2013; 180: 176.
    • (2013) J Surg Res , vol.180 , pp. 176
    • Lam, V.W.1    Laurence, J.M.2    Richardson, A.J.3    Pleass, H.C.4    Allen, R.D.5
  • 51
    • 84878845737 scopus 로고    scopus 로고
    • Systematic review and meta-analysis of hypothermic machine perfusion versus static cold storage of kidney allografts on transplant outcomes
    • O'Callaghan JM, Morgan RD, Knight SR, Morris PJ,. Systematic review and meta-analysis of hypothermic machine perfusion versus static cold storage of kidney allografts on transplant outcomes. Br J Surg 2013; 100: 991.
    • (2013) Br J Surg , vol.100 , pp. 991
    • O'Callaghan, J.M.1    Morgan, R.D.2    Knight, S.R.3    Morris, P.J.4
  • 52
    • 84874923556 scopus 로고    scopus 로고
    • Machine perfusion versus cold storage of kidneys derived from donation after cardiac death: A meta-analysis
    • Deng R, Gu G, Wang D, et al,. Machine perfusion versus cold storage of kidneys derived from donation after cardiac death: a meta-analysis. PLoS ONE 2013; 8: e56368.
    • (2013) PLoS ONE , vol.8 , pp. e56368
    • Deng, R.1    Gu, G.2    Wang, D.3
  • 53
    • 84877595232 scopus 로고    scopus 로고
    • Renal perfusion pump versus cold storage for donation after cardiac death kidneys: A systematic review
    • Bathini V, McGregor T, McAlister VC, Luke PP, Sener A,. Renal perfusion pump versus cold storage for donation after cardiac death kidneys: a systematic review. J Urol 2013; 189: 2214.
    • (2013) J Urol , vol.189 , pp. 2214
    • Bathini, V.1    McGregor, T.2    McAlister, V.C.3    Luke, P.P.4    Sener, A.5
  • 54
    • 84892427387 scopus 로고    scopus 로고
    • Hypothermic machine perfusion reduces delayed graft function and improves one-year graft survival of kidneys from expanded criteria donors: A meta-analysis
    • Jiao B, Liu S, Liu H, Cheng D, Cheng Y, Liu Y,. Hypothermic machine perfusion reduces delayed graft function and improves one-year graft survival of kidneys from expanded criteria donors: a meta-analysis. PLoS ONE 2013; 8: e81826.
    • (2013) PLoS ONE , vol.8 , pp. e81826
    • Jiao, B.1    Liu, S.2    Liu, H.3    Cheng, D.4    Cheng, Y.5    Liu, Y.6
  • 55
    • 70449561560 scopus 로고    scopus 로고
    • The effectiveness and cost-effectiveness of methods of storing donated kidneys from deceased donors: A systematic review and economic model
    • iii-iv, xi-xiv
    • Bond M, Pitt M, Akoh J, Moxham T, Hoyle M, Anderson R,. The effectiveness and cost-effectiveness of methods of storing donated kidneys from deceased donors: a systematic review and economic model. Health Technol Assess 2009; 13: iii-iv, xi-xiv, 1.
    • (2009) Health Technol Assess , vol.13 , pp. 1
    • Bond, M.1    Pitt, M.2    Akoh, J.3    Moxham, T.4    Hoyle, M.5    Anderson, R.6
  • 56
    • 84863221471 scopus 로고    scopus 로고
    • Cost-effectiveness of hypothermic machine preservation versus static cold storage in renal transplantation
    • Groen H, Moers C, Smits JM, et al,. Cost-effectiveness of hypothermic machine preservation versus static cold storage in renal transplantation. Am J Transplant 2012; 12: 1824.
    • (2012) Am J Transplant , vol.12 , pp. 1824
    • Groen, H.1    Moers, C.2    Smits, J.M.3
  • 58
    • 80053327103 scopus 로고    scopus 로고
    • The prognostic value of renal resistance during hypothermic machine perfusion of deceased donor kidneys
    • Jochmans I, Moers C, Smits JM, et al,. The prognostic value of renal resistance during hypothermic machine perfusion of deceased donor kidneys. Am J Transplant 2011; 11: 2214.
    • (2011) Am J Transplant , vol.11 , pp. 2214
    • Jochmans, I.1    Moers, C.2    Smits, J.M.3
  • 59
    • 84859632544 scopus 로고    scopus 로고
    • Hypothermic reconditioning of porcine kidney grafts by short-term preimplantation machine perfusion
    • Gallinat A, Paul A, Efferz P, et al,. Hypothermic reconditioning of porcine kidney grafts by short-term preimplantation machine perfusion. Transplantation 2012; 93: 787.
    • (2012) Transplantation , vol.93 , pp. 787
    • Gallinat, A.1    Paul, A.2    Efferz, P.3
  • 60
    • 85027937578 scopus 로고    scopus 로고
    • One or 4 h of "in-house" reconditioning by machine perfusion after cold storage improve reperfusion parameters in porcine kidneys
    • Gallinat A, Efferz P, Paul A, Minor T,. One or 4 h of "in-house" reconditioning by machine perfusion after cold storage improve reperfusion parameters in porcine kidneys. Transpl Int 2014; 27: 1214.
    • (2014) Transpl Int , vol.27 , pp. 1214
    • Gallinat, A.1    Efferz, P.2    Paul, A.3    Minor, T.4
  • 61
    • 79957673683 scopus 로고    scopus 로고
    • Hypothermic machine perfusion after static cold storage does not improve the preservation condition in an experimental porcine kidney model
    • Hosgood SA, Mohamed IH, Bagul A, Nicholson ML,. Hypothermic machine perfusion after static cold storage does not improve the preservation condition in an experimental porcine kidney model. Br J Surg 2011; 98: 943.
    • (2011) Br J Surg , vol.98 , pp. 943
    • Hosgood, S.A.1    Mohamed, I.H.2    Bagul, A.3    Nicholson, M.L.4
  • 62
    • 84871186245 scopus 로고    scopus 로고
    • Machine perfusion versus cold storage for the preservation of kidneys from donors ≥ 65 years allocated in the Eurotransplant Senior Programme
    • Gallinat A, Moers C, Treckmann J, et al,. Machine perfusion versus cold storage for the preservation of kidneys from donors ≥ 65 years allocated in the Eurotransplant Senior Programme. Nephrol Dial Transplant 2012; 27: 4458.
    • (2012) Nephrol Dial Transplant , vol.27 , pp. 4458
    • Gallinat, A.1    Moers, C.2    Treckmann, J.3
  • 63
    • 84896657886 scopus 로고    scopus 로고
    • Pulsatile perfusion reduces the risk of delayed graft function in deceased donor kidney transplants, irrespective of donor type and cold ischemic time
    • Gill J, Dong J, Eng M, Landsberg D, Gill JS,. Pulsatile perfusion reduces the risk of delayed graft function in deceased donor kidney transplants, irrespective of donor type and cold ischemic time. Transplantation 2014; 97: 668.
    • (2014) Transplantation , vol.97 , pp. 668
    • Gill, J.1    Dong, J.2    Eng, M.3    Landsberg, D.4    Gill, J.S.5
  • 64
    • 33846941158 scopus 로고    scopus 로고
    • Multicenter analysis of kidney preservation
    • Opelz G, Dohler B,. Multicenter analysis of kidney preservation. Transplantation 2007; 83: 247.
    • (2007) Transplantation , vol.83 , pp. 247
    • Opelz, G.1    Dohler, B.2
  • 65
    • 40449114234 scopus 로고    scopus 로고
    • Determinants of discard of expanded criteria donor kidneys: Impact of biopsy and machine perfusion
    • Sung RS, Christensen LL, Leichtman AB, et al,. Determinants of discard of expanded criteria donor kidneys: impact of biopsy and machine perfusion. Am J Transplant 2008; 8: 783.
    • (2008) Am J Transplant , vol.8 , pp. 783
    • Sung, R.S.1    Christensen, L.L.2    Leichtman, A.B.3
  • 66
    • 84864614153 scopus 로고    scopus 로고
    • Deceased-donor kidney perfusate and urine biomarkers for kidney allograft outcomes: A systematic review
    • Bhangoo RS, Hall IE, Reese PP, Parikh CR,. Deceased-donor kidney perfusate and urine biomarkers for kidney allograft outcomes: a systematic review. Nephrol Dial Transplant 2012; 27: 3305.
    • (2012) Nephrol Dial Transplant , vol.27 , pp. 3305
    • Bhangoo, R.S.1    Hall, I.E.2    Reese, P.P.3    Parikh, C.R.4
  • 67
    • 0037230517 scopus 로고    scopus 로고
    • Use of two biomarkers of renal ischemia to assess machine-perfused non-heart-beating donor kidneys
    • Gok MA, Pelsers M, Glatz JF, et al,. Use of two biomarkers of renal ischemia to assess machine-perfused non-heart-beating donor kidneys. Clin Chem 2003; 49: 172.
    • (2003) Clin Chem , vol.49 , pp. 172
    • Gok, M.A.1    Pelsers, M.2    Glatz, J.F.3
  • 68
    • 10744227650 scopus 로고    scopus 로고
    • Do tissue damage biomarkers used to assess machine-perfused NHBD kidneys predict long-term renal function post-transplant?
    • Gok MA, Pelzers M, Glatz JF, et al,. Do tissue damage biomarkers used to assess machine-perfused NHBD kidneys predict long-term renal function post-transplant? Clin Chim Acta 2003; 338: 33.
    • (2003) Clin Chim Acta , vol.338 , pp. 33
    • Gok, M.A.1    Pelzers, M.2    Glatz, J.F.3
  • 69
    • 0031034012 scopus 로고    scopus 로고
    • Glutathione-S-transferase as predictor of functional outcome in transplantation of machine-preserved non-heart-beating donor kidneys
    • Daemen JW, Oomen AP, Janssen MA, et al,. Glutathione-S-transferase as predictor of functional outcome in transplantation of machine-preserved non-heart-beating donor kidneys. Transplantation 1997; 63: 89.
    • (1997) Transplantation , vol.63 , pp. 89
    • Daemen, J.W.1    Oomen, A.P.2    Janssen, M.A.3
  • 70
    • 78650256684 scopus 로고    scopus 로고
    • The value of machine perfusion perfusate biomarkers for predicting kidney transplant outcome
    • Moers C, Varnav OC, van Heurn E, et al,. The value of machine perfusion perfusate biomarkers for predicting kidney transplant outcome. Transplantation 2010; 90: 966.
    • (2010) Transplantation , vol.90 , pp. 966
    • Moers, C.1    Varnav, O.C.2    Van Heurn, E.3
  • 71
    • 77957205277 scopus 로고    scopus 로고
    • A risk prediction model for delayed graft function in the current era of deceased donor renal transplantation
    • Irish WD, Ilsley JN, Schnitzler MA, Feng S, Brennan DC,. A risk prediction model for delayed graft function in the current era of deceased donor renal transplantation. Am J Transplant 2010; 10: 2279.
    • (2010) Am J Transplant , vol.10 , pp. 2279
    • Irish, W.D.1    Ilsley, J.N.2    Schnitzler, M.A.3    Feng, S.4    Brennan, D.C.5
  • 72
    • 0142244840 scopus 로고    scopus 로고
    • Nomogram for predicting the likelihood of delayed graft function in adult cadaveric renal transplant recipients
    • Irish WD, McCollum DA, Tesi RJ, et al,. Nomogram for predicting the likelihood of delayed graft function in adult cadaveric renal transplant recipients. J Am Soc Nephrol 2003; 14: 2967.
    • (2003) J Am Soc Nephrol , vol.14 , pp. 2967
    • Irish, W.D.1    McCollum, D.A.2    Tesi, R.J.3
  • 73
    • 68249094407 scopus 로고    scopus 로고
    • A comprehensive risk quantification score for deceased donor kidneys: The kidney donor risk index
    • Rao PS, Schaubel DE, Guidinger MK, et al,. A comprehensive risk quantification score for deceased donor kidneys: the kidney donor risk index. Transplantation 2009; 88: 231.
    • (2009) Transplantation , vol.88 , pp. 231
    • Rao, P.S.1    Schaubel, D.E.2    Guidinger, M.K.3
  • 74
    • 77950940967 scopus 로고    scopus 로고
    • A comparison of hypothermic machine perfusion versus static cold storage in an experimental model of renal ischemia reperfusion injury
    • Hosgood SA, Yang B, Bagul A, Mohamed IH, Nicholson ML,. A comparison of hypothermic machine perfusion versus static cold storage in an experimental model of renal ischemia reperfusion injury. Transplantation 2010; 89: 830.
    • (2010) Transplantation , vol.89 , pp. 830
    • Hosgood, S.A.1    Yang, B.2    Bagul, A.3    Mohamed, I.H.4    Nicholson, M.L.5
  • 75
    • 78951471285 scopus 로고    scopus 로고
    • Analysis of machine perfusion benefits in kidney grafts: A preclinical study
    • Vaziri N, Thuillier R, Favreau FD, et al,. Analysis of machine perfusion benefits in kidney grafts: a preclinical study. J Transl Med 2011; 9: 15.
    • (2011) J Transl Med , vol.9 , pp. 15
    • Vaziri, N.1    Thuillier, R.2    Favreau, F.D.3
  • 76
    • 83555173251 scopus 로고    scopus 로고
    • Renoprotective effect of pulsatile perfusion machine RM3: Pathophysiological and kidney injury biomarker characterization in a preclinical model of autotransplanted pig
    • Codas R, Thuillier R, Hauet T, Badet L,. Renoprotective effect of pulsatile perfusion machine RM3: pathophysiological and kidney injury biomarker characterization in a preclinical model of autotransplanted pig. BJU Int 2012; 109: 141.
    • (2012) BJU Int , vol.109 , pp. 141
    • Codas, R.1    Thuillier, R.2    Hauet, T.3    Badet, L.4
  • 77
    • 67650799641 scopus 로고    scopus 로고
    • An in vivo autotransplant model of renal preservation: Cold storage versus machine perfusion in the prevention of ischemia/reperfusion injury
    • La Manna G, Conte D, Cappuccilli ML, et al,. An in vivo autotransplant model of renal preservation: cold storage versus machine perfusion in the prevention of ischemia/reperfusion injury. Artif Organs 2009; 33: 565.
    • (2009) Artif Organs , vol.33 , pp. 565
    • La Manna, G.1    Conte, D.2    Cappuccilli, M.L.3
  • 78
    • 78751647606 scopus 로고    scopus 로고
    • Perfusion storage reduces apoptosis in a porcine kidney model of donation after cardiac death
    • Jani A, Zimmerman M, Martin J, et al,. Perfusion storage reduces apoptosis in a porcine kidney model of donation after cardiac death. Transplantation 2011; 91: 169.
    • (2011) Transplantation , vol.91 , pp. 169
    • Jani, A.1    Zimmerman, M.2    Martin, J.3
  • 79
    • 77954958153 scopus 로고    scopus 로고
    • Flow cessation triggers endothelial dysfunction during organ cold storage conditions: Strategies for pharmacologic intervention
    • Gracia-Sancho J, Villarreal G Jr, Zhang Y, et al,. Flow cessation triggers endothelial dysfunction during organ cold storage conditions: strategies for pharmacologic intervention. Transplantation 2010; 90: 142.
    • (2010) Transplantation , vol.90 , pp. 142
    • Gracia-Sancho, J.1    Villarreal, Jr.G.2    Zhang, Y.3
  • 80
    • 80054692433 scopus 로고    scopus 로고
    • Normothermic versus hypothermic ex vivo flush using a novel phosphate-free preservation solution (AQIX) in porcine kidneys
    • Kay MD, Hosgood SA, Harper SJ, Bagul A, Waller HL, Nicholson ML,. Normothermic versus hypothermic ex vivo flush using a novel phosphate-free preservation solution (AQIX) in porcine kidneys. J Surg Res 2011; 171: 275.
    • (2011) J Surg Res , vol.171 , pp. 275
    • Kay, M.D.1    Hosgood, S.A.2    Harper, S.J.3    Bagul, A.4    Waller, H.L.5    Nicholson, M.L.6
  • 81
    • 71749116861 scopus 로고    scopus 로고
    • Room temperature pulsatile perfusion of renal allografts with Lifor compared with hypothermic machine pump solution
    • Gage F, Leeser DB, Porterfield NK, et al,. Room temperature pulsatile perfusion of renal allografts with Lifor compared with hypothermic machine pump solution. Transplant Proc 2009; 41: 3571.
    • (2009) Transplant Proc , vol.41 , pp. 3571
    • Gage, F.1    Leeser, D.B.2    Porterfield, N.K.3
  • 82
    • 84908236842 scopus 로고    scopus 로고
    • Modifying the vessel walls in porcine kidneys during machine perfusion
    • Sedigh A, Larsson R, Brannstrom J, et al,. Modifying the vessel walls in porcine kidneys during machine perfusion. J Surg Res 2014; 191: 455.
    • (2014) J Surg Res , vol.191 , pp. 455
    • Sedigh, A.1    Larsson, R.2    Brannstrom, J.3
  • 83
    • 79961020837 scopus 로고    scopus 로고
    • Addition of a water-soluble propofol formulation to preservation solution in experimental kidney transplantation
    • Snoeijs MG, Vaahtera L, de Vries EE, et al,. Addition of a water-soluble propofol formulation to preservation solution in experimental kidney transplantation. Transplantation 2011; 92: 296.
    • (2011) Transplantation , vol.92 , pp. 296
    • Snoeijs, M.G.1    Vaahtera, L.2    De Vries, E.E.3
  • 84
    • 84877627082 scopus 로고    scopus 로고
    • Gaseous hydrogen sulfide protects against myocardial ischemia-reperfusion injury in mice partially independent from hypometabolism
    • Snijder PM, de Boer RA, Bos EM, et al,. Gaseous hydrogen sulfide protects against myocardial ischemia-reperfusion injury in mice partially independent from hypometabolism. PLoS ONE 2013; 8: e63291.
    • (2013) PLoS ONE , vol.8 , pp. e63291
    • Snijder, P.M.1    De Boer, R.A.2    Bos, E.M.3
  • 85
    • 84868659904 scopus 로고    scopus 로고
    • Effects of hydrogen sulphide in an experimental model of renal ischaemia-reperfusion injury
    • Hunter JP, Hosgood SA, Patel M, Rose R, Read K, Nicholson ML,. Effects of hydrogen sulphide in an experimental model of renal ischaemia-reperfusion injury. Br J Surg 2012; 99: 1665.
    • (2012) Br J Surg , vol.99 , pp. 1665
    • Hunter, J.P.1    Hosgood, S.A.2    Patel, M.3    Rose, R.4    Read, K.5    Nicholson, M.L.6
  • 86
    • 84873268960 scopus 로고    scopus 로고
    • Detrimental effects of prolonged warm renal ischaemia-reperfusion injury are abrogated by supplemental hydrogen sulphide: An analysis using real-time intravital microscopy and polymerase chain reaction
    • Zhu JX, Kalbfleisch M, Yang YX, et al,. Detrimental effects of prolonged warm renal ischaemia-reperfusion injury are abrogated by supplemental hydrogen sulphide: an analysis using real-time intravital microscopy and polymerase chain reaction. BJU Int 2012; 110: E1218.
    • (2012) BJU Int , vol.110 , pp. E1218
    • Zhu, J.X.1    Kalbfleisch, M.2    Yang, Y.X.3
  • 87
    • 74549211813 scopus 로고    scopus 로고
    • Hydrogen sulphide ameliorates ischaemia-reperfusion injury in an experimental model of non-heart-beating donor kidney transplantation
    • Hosgood SA, Nicholson ML,. Hydrogen sulphide ameliorates ischaemia-reperfusion injury in an experimental model of non-heart-beating donor kidney transplantation. Br J Surg 2010; 97: 202.
    • (2010) Br J Surg , vol.97 , pp. 202
    • Hosgood, S.A.1    Nicholson, M.L.2
  • 89
    • 79953726308 scopus 로고    scopus 로고
    • Synthetic small interfering RNA down-regulates caspase-3 and affects apoptosis, IL-1 beta, and viability of porcine proximal tubular cells
    • Yang B, Elias JE, Bloxham M, Nicholson ML,. Synthetic small interfering RNA down-regulates caspase-3 and affects apoptosis, IL-1 beta, and viability of porcine proximal tubular cells. J Cell Biochem 2011; 112: 1337.
    • (2011) J Cell Biochem , vol.112 , pp. 1337
    • Yang, B.1    Elias, J.E.2    Bloxham, M.3    Nicholson, M.L.4
  • 91
    • 84872897633 scopus 로고    scopus 로고
    • Machine perfusion in organ transplantation: A tool for ex-vivo graft conditioning with mesenchymal stem cells?
    • Van Raemdonck D, Neyrinck A, Rega F, Devos T, Pirenne J,. Machine perfusion in organ transplantation: a tool for ex-vivo graft conditioning with mesenchymal stem cells? Curr Opin Organ Transplant 2013; 18: 24.
    • (2013) Curr Opin Organ Transplant , vol.18 , pp. 24
    • Van Raemdonck, D.1    Neyrinck, A.2    Rega, F.3    Devos, T.4    Pirenne, J.5
  • 92
    • 31644450990 scopus 로고    scopus 로고
    • Administered mesenchymal stem cells enhance recovery from ischemia/reperfusion-induced acute renal failure in rats
    • Lange C, Togel F, Ittrich H, et al,. Administered mesenchymal stem cells enhance recovery from ischemia/reperfusion-induced acute renal failure in rats. Kidney Int 2005; 68: 1613.
    • (2005) Kidney Int , vol.68 , pp. 1613
    • Lange, C.1    Togel, F.2    Ittrich, H.3
  • 93
    • 84863338204 scopus 로고    scopus 로고
    • Induction therapy with autologous mesenchymal stem cells in living-related kidney transplants: A randomized controlled trial
    • Tan J, Wu W, Xu X, et al,. Induction therapy with autologous mesenchymal stem cells in living-related kidney transplants: a randomized controlled trial. JAMA 2012; 307: 1169.
    • (2012) JAMA , vol.307 , pp. 1169
    • Tan, J.1    Wu, W.2    Xu, X.3
  • 94
    • 84872090856 scopus 로고    scopus 로고
    • Donor-derived mesenchymal stem cells combined with low-dose Tacrolimus prevent acute rejection after renal transplantation: A clinical pilot study
    • Peng Y, Ke M, Xu L, et al,. Donor-derived mesenchymal stem cells combined with low-dose Tacrolimus prevent acute rejection after renal transplantation: a clinical pilot study. Transplantation 2013; 95: 161.
    • (2013) Transplantation , vol.95 , pp. 161
    • Peng, Y.1    Ke, M.2    Xu, L.3
  • 95
    • 84882450956 scopus 로고    scopus 로고
    • Mesenchymal stromal cells and kidney transplantation: Pretransplant infusion protects from graft dysfunction while fostering immunoregulation
    • Perico N, Casiraghi F, Gotti E, et al,. Mesenchymal stromal cells and kidney transplantation: pretransplant infusion protects from graft dysfunction while fostering immunoregulation. Transpl Int 2013; 26: 867.
    • (2013) Transpl Int , vol.26 , pp. 867
    • Perico, N.1    Casiraghi, F.2    Gotti, E.3
  • 96
    • 84925388140 scopus 로고    scopus 로고
    • Subnormothermic machine perfusion for preservation of porcine kidneys in a donation after circulatory death model
    • Hoyer DP, Gallinat A, Swoboda S, et al,. Subnormothermic machine perfusion for preservation of porcine kidneys in a donation after circulatory death model. Transpl Int 2014; 27: 1097.
    • (2014) Transpl Int , vol.27 , pp. 1097
    • Hoyer, D.P.1    Gallinat, A.2    Swoboda, S.3
  • 97
    • 33845641787 scopus 로고    scopus 로고
    • Static normothermic preservation of renal allografts using a novel nonphosphate buffered preservation solution
    • Kay MD, Hosgood SA, Harper SJF, et al,. Static normothermic preservation of renal allografts using a novel nonphosphate buffered preservation solution. Transpl Int 2007; 20: 88.
    • (2007) Transpl Int , vol.20 , pp. 88
    • Kay, M.D.1    Hosgood, S.A.2    Harper, S.J.F.3
  • 98
    • 84904732719 scopus 로고    scopus 로고
    • "Resuscitation" of marginal liver allografts for transplantation with machine perfusion technology
    • Graham JA, Guarrera JV,. "Resuscitation" of marginal liver allografts for transplantation with machine perfusion technology. J Hepatol 2014; 61: 418.
    • (2014) J Hepatol , vol.61 , pp. 418
    • Graham, J.A.1    Guarrera, J.V.2
  • 99
    • 84929332024 scopus 로고    scopus 로고
    • Normothermic machine perfusion of the kidney: Better conditioning and repair?
    • Hosgood SA, van Heurn E, Nicholson ML,. Normothermic machine perfusion of the kidney: better conditioning and repair? Transpl Int 2014. doi: 10.1111/tri.12319.
    • (2014) Transpl Int
    • Hosgood, S.A.1    Van Heurn, E.2    Nicholson, M.L.3
  • 100
    • 84908242705 scopus 로고    scopus 로고
    • The effects of arterial pressure during normothermic kidney perfusion
    • Patel M, Hosgood S, Nicholson ML,. The effects of arterial pressure during normothermic kidney perfusion. J Surg Res 2014; 191: 463.
    • (2014) J Surg Res , vol.191 , pp. 463
    • Patel, M.1    Hosgood, S.2    Nicholson, M.L.3
  • 101
    • 84895061724 scopus 로고    scopus 로고
    • Ex vivo normothermic perfusion of declined human kidneys after inadequate in situ perfusion
    • Hosgood SA, Nicholson ML,. Ex vivo normothermic perfusion of declined human kidneys after inadequate in situ perfusion. Am J Transplant 2013; 14: 490.
    • (2013) Am J Transplant , vol.14 , pp. 490
    • Hosgood, S.A.1    Nicholson, M.L.2
  • 102
    • 84876891728 scopus 로고    scopus 로고
    • Renal transplantation after ex vivo normothermic perfusion: The first clinical study
    • Nicholson ML, Hosgood SA,. Renal transplantation after ex vivo normothermic perfusion: the first clinical study. Am J Transplant 2013; 13: 1246.
    • (2013) Am J Transplant , vol.13 , pp. 1246
    • Nicholson, M.L.1    Hosgood, S.A.2
  • 104
    • 80053322953 scopus 로고    scopus 로고
    • First in man renal transplantation after ex vivo normothermic perfusion
    • Hosgood SA, Nicholson ML,. First in man renal transplantation after ex vivo normothermic perfusion. Transplantation 2011; 92: 735.
    • (2011) Transplantation , vol.92 , pp. 735
    • Hosgood, S.A.1    Nicholson, M.L.2
  • 105
    • 80053304605 scopus 로고    scopus 로고
    • A pilot study assessing the feasibility of a short period of normothermic preservation in an experimental model of non heart beating donor kidneys
    • Hosgood SA, Barlow AD, Yates PJ, Snoeijs MG, van Heurn EL, Nicholson ML,. A pilot study assessing the feasibility of a short period of normothermic preservation in an experimental model of non heart beating donor kidneys. J Surg Res 2011; 171: 283.
    • (2011) J Surg Res , vol.171 , pp. 283
    • Hosgood, S.A.1    Barlow, A.D.2    Yates, P.J.3    Snoeijs, M.G.4    Van Heurn, E.L.5    Nicholson, M.L.6
  • 106
    • 84881044026 scopus 로고    scopus 로고
    • Oxygen consumption during oxygenated hypothermic perfusion as a measure of donor organ viability
    • Bunegin L, Tolstykh GP, Gelineau JF, Cosimi AB, Anderson LM,. Oxygen consumption during oxygenated hypothermic perfusion as a measure of donor organ viability. ASAIO J 2013; 59: 427.
    • (2013) ASAIO J , vol.59 , pp. 427
    • Bunegin, L.1    Tolstykh, G.P.2    Gelineau, J.F.3    Cosimi, A.B.4    Anderson, L.M.5
  • 108
    • 34047103560 scopus 로고    scopus 로고
    • Hypothermic perfusion preservation: The future of organ preservation revisited?
    • Fuller BJ, Lee CY,. Hypothermic perfusion preservation: the future of organ preservation revisited? Cryobiology 2007; 54: 129.
    • (2007) Cryobiology , vol.54 , pp. 129
    • Fuller, B.J.1    Lee, C.Y.2
  • 110
    • 0037181436 scopus 로고    scopus 로고
    • Overcoming severe renal ischemia: The role of ex vivo warm perfusion
    • Brasile L, Stubenitsky BM, Booster MH, et al,. Overcoming severe renal ischemia: the role of ex vivo warm perfusion. Transplantation 2002; 73: 897.
    • (2002) Transplantation , vol.73 , pp. 897
    • Brasile, L.1    Stubenitsky, B.M.2    Booster, M.H.3
  • 112
    • 80052272787 scopus 로고    scopus 로고
    • Supplementation with a new therapeutic oxygen carrier reduces chronic fibrosis and organ dysfunction in kidney static preservation
    • Thuillier R, Dutheil D, Trieu MT, et al,. Supplementation with a new therapeutic oxygen carrier reduces chronic fibrosis and organ dysfunction in kidney static preservation. Am J Transplant 2011; 11: 1845.
    • (2011) Am J Transplant , vol.11 , pp. 1845
    • Thuillier, R.1    Dutheil, D.2    Trieu, M.T.3
  • 113
    • 84883858025 scopus 로고    scopus 로고
    • Benefits of active oxygenation during hypothermic machine perfusion of kidneys in a preclinical model of deceased after cardiac death donors
    • Thuillier R, Allain G, Celhay O, et al,. Benefits of active oxygenation during hypothermic machine perfusion of kidneys in a preclinical model of deceased after cardiac death donors. J Surg Res 2013; 184: 1174.
    • (2013) J Surg Res , vol.184 , pp. 1174
    • Thuillier, R.1    Allain, G.2    Celhay, O.3
  • 114
    • 84868203171 scopus 로고    scopus 로고
    • Role of oxygenation in hypothermic machine perfusion of kidneys from heart beating donors
    • Gallinat A, Paul A, Efferz P, et al,. Role of oxygenation in hypothermic machine perfusion of kidneys from heart beating donors. Transplantation 2012; 94: 809.
    • (2012) Transplantation , vol.94 , pp. 809
    • Gallinat, A.1    Paul, A.2    Efferz, P.3
  • 115
    • 36549079087 scopus 로고    scopus 로고
    • Improved kidney graft function after preservation using a novel hypothermic machine perfusion device
    • Maathuis M-HJ, Manekeller S, van der Plaats A, et al,. Improved kidney graft function after preservation using a novel hypothermic machine perfusion device. Ann Surg 2007; 246: 982.
    • (2007) Ann Surg , vol.246 , pp. 982
    • Maathuis, M.-H.1    Manekeller, S.2    Van Der Plaats, A.3
  • 116
    • 71449101644 scopus 로고    scopus 로고
    • Evaluation of a novel system for hypothermic oxygenated pulsatile perfusion preservation
    • Doorschodt BM, Schreinemachers MC, Florquin S, et al,. Evaluation of a novel system for hypothermic oxygenated pulsatile perfusion preservation. Int J Artif Organs 2009; 32: 728.
    • (2009) Int J Artif Organs , vol.32 , pp. 728
    • Doorschodt, B.M.1    Schreinemachers, M.C.2    Florquin, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.