메뉴 건너뛰기




Volumn 44, Issue 7, 2012, Pages 2207-2212

Prognostic utility of hypothermic machine perfusion in deceased donor renal transplantation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANOXIA; CAUSE OF DEATH; CEREBROVASCULAR ACCIDENT; CHRONIC ALLOGRAFT NEPHROPATHY; CONFERENCE PAPER; CREATININE CLEARANCE; DELAYED GRAFT FUNCTION; FEMALE; FLOW RATE; GRAFT SURVIVAL; HUMAN; INCIDENCE; KIDNEY PERFUSION; KIDNEY TRANSPLANTATION; MAJOR CLINICAL STUDY; MALE; MEDICAL DEVICE; PRIORITY JOURNAL; PROGNOSIS; RETROSPECTIVE STUDY; TEMPERATURE; THROMBOSIS;

EID: 84866343376     PISSN: 00411345     EISSN: 18732623     Source Type: Journal    
DOI: 10.1016/j.transproceed.2012.07.129     Document Type: Conference Paper
Times cited : (40)

References (13)
  • 1
    • 58249089430 scopus 로고    scopus 로고
    • Machine perfusion or cold storage in deceased-donor kidney transplantation
    • C. Moers, J.M. Smits, M.H. Maathuis Machine perfusion or cold storage in deceased-donor kidney transplantation N Engl J Med 360 2009 7
    • (2009) N Engl J Med , vol.360 , pp. 7
    • Moers, C.1    Smits, J.M.2    Maathuis, M.H.3
  • 2
    • 79955569761 scopus 로고    scopus 로고
    • Machine perfusion versus cold storage for preservation of kidneys from expanded criteria donors after brain death
    • J. Treckmann, C. Moers, J.M. Smits Machine perfusion versus cold storage for preservation of kidneys from expanded criteria donors after brain death Transplant Int 24 2011 548
    • (2011) Transplant Int , vol.24 , pp. 548
    • Treckmann, J.1    Moers, C.2    Smits, J.M.3
  • 3
    • 78349296703 scopus 로고    scopus 로고
    • Favorable outcomes with machine perfusion and longer pump times in kidney transplantation: A single-center, observational study
    • G. Ciancio, J.J. Gaynor, J. Sageshima Favorable outcomes with machine perfusion and longer pump times in kidney transplantation: a single-center, observational study Transplantation 90 2010 882
    • (2010) Transplantation , vol.90 , pp. 882
    • Ciancio, G.1    Gaynor, J.J.2    Sageshima, J.3
  • 4
    • 16244409835 scopus 로고    scopus 로고
    • Use of perfusion parameters in predicting out-comes of machine-preserved kidneys
    • M.F. Mozes, R.B. Skolek, B.C. Korf Use of perfusion parameters in predicting out-comes of machine-preserved kidneys Trans Proc 37 2005 350
    • (2005) Trans Proc , vol.37 , pp. 350
    • Mozes, M.F.1    Skolek, R.B.2    Korf, B.C.3
  • 5
    • 0017926051 scopus 로고
    • Flow and function in machine-preserved kidneys
    • D. Sampson, H.M. Jun, P. Walczak Flow and function in machine-preserved kidneys Brit J Surg 65 1978 37
    • (1978) Brit J Surg , vol.65 , pp. 37
    • Sampson, D.1    Jun, H.M.2    Walczak, P.3
  • 6
    • 80053327103 scopus 로고    scopus 로고
    • The prognostic value of renal resistance during hypothermic machine perfusion of deceased donor kidneys
    • I. Jochmans, C. Moers, J.M. Smits The prognostic value of renal resistance during hypothermic machine perfusion of deceased donor kidneys Am Journal Transplantation 11 2011 2214
    • (2011) Am Journal Transplantation , vol.11 , pp. 2214
    • Jochmans, I.1    Moers, C.2    Smits, J.M.3
  • 7
    • 0028197406 scopus 로고
    • Pulsatile kidney perfusion for evaluation of high-risk kidney donors safely expands the donor pool
    • R.J. Tesi, E.A. Elkhammas, E.A. Davies Pulsatile kidney perfusion for evaluation of high-risk kidney donors safely expands the donor pool Clin Transplant 8 2 Pt 1 1994 134
    • (1994) Clin Transplant , vol.8 , Issue.2 PART 1 , pp. 134
    • Tesi, R.J.1    Elkhammas, E.A.2    Davies, E.A.3
  • 8
    • 78349293444 scopus 로고    scopus 로고
    • Machine perfusion versus cold storage for the preservation of kidneys donated after cardiac death: A multicenter, randomized, controlled trial
    • I. Jochmans, C. Moers, J.M. Smits Machine perfusion versus cold storage for the preservation of kidneys donated after cardiac death: a multicenter, randomized, controlled trial Ann Surg 252 2010 756
    • (2010) Ann Surg , vol.252 , pp. 756
    • Jochmans, I.1    Moers, C.2    Smits, J.M.3
  • 9
    • 77950940967 scopus 로고    scopus 로고
    • A comparison of hypothermic machine perfusion versus static cold storage in an experimental model of renal ischemia reperfusion injury
    • S.A. Hosgood, B. Yang, A. Bagul A comparison of hypothermic machine perfusion versus static cold storage in an experimental model of renal ischemia reperfusion injury Transplantation 89 2010 830
    • (2010) Transplantation , vol.89 , pp. 830
    • Hosgood, S.A.1    Yang, B.2    Bagul, A.3
  • 10
    • 79954571326 scopus 로고    scopus 로고
    • Graft quality assessment in kidney transplantation: Not an exact science yet!
    • Jochmans I, Pirenne J: Graft quality assessment in kidney transplantation: not an exact science yet! Current opinion in organ transplantation. 16:174, 2011
    • (2011) Current Opinion in Organ Transplantation , vol.16 , pp. 174
    • Jochmans, I.1    Pirenne, J.2
  • 11
    • 83955161708 scopus 로고    scopus 로고
    • Machine perfusion following static cold storage preservation in kidney transplantation: Donor-matched pair analysis of the prognostic impact of longer pump time
    • G. Ciancio, J.J. Gaynor, J. Sageshima Machine perfusion following static cold storage preservation in kidney transplantation: donor-matched pair analysis of the prognostic impact of longer pump time Transplant Int 25 2012 34
    • (2012) Transplant Int , vol.25 , pp. 34
    • Ciancio, G.1    Gaynor, J.J.2    Sageshima, J.3
  • 12
    • 80051546220 scopus 로고    scopus 로고
    • Illinois statewide dual kidney transplantation experience-are we appropriately selecting kidneys?
    • C.M. Hugen, A.J. Polcari, R. Skolek Illinois statewide dual kidney transplantation experience-are we appropriately selecting kidneys? The J Urol 86 2011 996
    • (2011) The J Urol , vol.86 , pp. 996
    • Hugen, C.M.1    Polcari, A.J.2    Skolek, R.3
  • 13


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.