메뉴 건너뛰기




Volumn 92, Issue 7, 2011, Pages 735-738

First in man renal transplantation after ex vivo normothermic perfusion

Author keywords

Extended criteria donor; Kidney transplantation; Normothermic perfusion

Indexed keywords

BASILIXIMAB; CREATININE; METHYLPREDNISOLONE; MYCOPHENOLIC ACID 2 MORPHOLINOETHYL ESTER; PREDNISOLONE; TACROLIMUS; THYMOCYTE ANTIBODY;

EID: 80053322953     PISSN: 00411337     EISSN: None     Source Type: Journal    
DOI: 10.1097/TP.0b013e31822d4e04     Document Type: Article
Times cited : (156)

References (18)
  • 1
    • 0038751995 scopus 로고    scopus 로고
    • Expanded criteria donors for kidney transplantation
    • Metzger RA, Delmonico FL, Feng S, et al. Expanded criteria donors for kidney transplantation. Am J Transplant 2003; 3(suppl 4): 114.
    • (2003) Am J Transplant , vol.3 , Issue.SUPPL. 4 , pp. 114
    • Metzger, R.A.1    Delmonico, F.L.2    Feng, S.3
  • 2
    • 77957205277 scopus 로고    scopus 로고
    • A risk prediction model for delayed graft function in the current era of deceased donor renal transplantation
    • Irish WD, Ilsley JN, Schnitzler MA, et al. A risk prediction model for delayed graft function in the current era of deceased donor renal transplantation. Am J Transplant 2010; 10: 2279.
    • (2010) Am J Transplant , vol.10 , pp. 2279
    • Irish, W.D.1    Ilsley, J.N.2    Schnitzler, M.A.3
  • 3
    • 58249089430 scopus 로고    scopus 로고
    • Machine perfusion or cold storage in deceased-donor kidney transplantation
    • Moers C, Smits JM, Maathuis MH, et al. Machine perfusion or cold storage in deceased-donor kidney transplantation. N Engl J Med 2009; 360: 7.
    • (2009) N Engl J Med , vol.360 , pp. 7
    • Moers, C.1    Smits, J.M.2    Maathuis, M.H.3
  • 4
    • 77956165611 scopus 로고    scopus 로고
    • Cold machine perfusion versus static cold storage of kidneys donated after cardiac death: A UK Multicenter randomized controlled trial
    • Watson CJE, Wells AC, Roberts RJ, et al. Cold machine perfusion versus static cold storage of kidneys donated after cardiac death: A UK Multicenter randomized controlled trial. Am J Transplant 2010; 10: 1991.
    • (2010) Am J Transplant , vol.10 , pp. 1991
    • Watson, C.J.E.1    Wells, A.C.2    Roberts, R.J.3
  • 5
    • 54549126503 scopus 로고    scopus 로고
    • The 1-year follow-up of the PROTECT patient population using the Organ Care System
    • Tenderich G, Tsui S, El-Banayosy A, et al. The 1-year follow-up of the PROTECT patient population using the Organ Care System. J Heart Lung Transplant 2008; 27(S2): S166.
    • (2008) J Heart Lung Transplant , vol.27 , Issue.S2
    • Tenderich, G.1    Tsui, S.2    El-Banayosy, A.3
  • 6
    • 66149119108 scopus 로고    scopus 로고
    • Prospective multicenter safety and effectiveness evaluation of the Organ Care System device of cardiac use (PROCEED)
    • McCurry K, Jeevanandam V, Mihaljevic T, et al. Prospective multicenter safety and effectiveness evaluation of the Organ Care System device of cardiac use (PROCEED). J Heart Lung Transplant 2008; 27(S2): S166.
    • (2008) J Heart Lung Transplant , vol.27 , Issue.S2
    • McCurry, K.1    Jeevanandam, V.2    Mihaljevic, T.3
  • 7
    • 0035901275 scopus 로고    scopus 로고
    • Transplantation of lungs from a non-heart-beating donor
    • Steen S, Sjöberg T, Pierre L, et al. Transplantation of lungs from a non-heart-beating donor. Lancet 2001; 357: 825.
    • (2001) Lancet , vol.357 , pp. 825
    • Steen, S.1    Sjöberg, T.2    Pierre, L.3
  • 8
    • 38549138539 scopus 로고    scopus 로고
    • Experimental renal preservation by normothermic resuscitation perfusion with autologous blood
    • Bagul A, Hosgood SA, Kaushik M, et al. Experimental renal preservation by normothermic resuscitation perfusion with autologous blood. Br J Surg 2008; 95: 111.
    • (2008) Br J Surg , vol.95 , pp. 111
    • Bagul, A.1    Hosgood, S.A.2    Kaushik, M.3
  • 9
    • 80053304605 scopus 로고    scopus 로고
    • A pilot study assessing the feasibility of a short period of normothermic preservation in an experimental model of non heart beating donor kidneys
    • [Epub ahead of print. doi:10.1016/j.jss.2010.01.027]
    • Hosgood SA, Barlow AD, Yates PJ, et al. A pilot study assessing the feasibility of a short period of normothermic preservation in an experimental model of non heart beating donor kidneys. J Surg Res 2011 [Epub ahead of print. doi:10.1016/j.jss.2010.01.027].
    • (2011) J Surg Res
    • Hosgood, S.A.1    Barlow, A.D.2    Yates, P.J.3
  • 10
    • 33646469126 scopus 로고    scopus 로고
    • Leucocyte depletion improves renal function during reperfusion using an experimental isolated haemoperfused organ preservation system
    • Harper S, Hosgood S, Kay M, et al. Leucocyte depletion improves renal function during reperfusion using an experimental isolated haemoperfused organ preservation system. Br J Surg 2006; 93: 623.
    • (2006) Br J Surg , vol.93 , pp. 623
    • Harper, S.1    Hosgood, S.2    Kay, M.3
  • 11
    • 33745823481 scopus 로고    scopus 로고
    • Effects of arterial pressure in an experimental isolated haemoperfused porcine kidney preservation system
    • Hosgood S, Harper S, Kay M, et al. Effects of arterial pressure in an experimental isolated haemoperfused porcine kidney preservation system. Br J Surg 2006; 93: 879.
    • (2006) Br J Surg , vol.93 , pp. 879
    • Hosgood, S.1    Harper, S.2    Kay, M.3
  • 12
    • 0025275321 scopus 로고
    • Autoregulation and tubuloglomerular feedback in juxtamedullary glomerular arterioles
    • Casellas D, Moore LC. Autoregulation and tubuloglomerular feedback in juxtamedullary glomerular arterioles. Am J Physiol 1990; 258: F660.
    • (1990) Am J Physiol , vol.258
    • Casellas, D.1    Moore, L.C.2
  • 13
    • 67649845519 scopus 로고    scopus 로고
    • Functional, metabolic, and morphological aspects of continuous, normothermic heart preservation: Effects of different preparation and perfusion techniques
    • Garbade J, Krautz C, Aupperle H, et al. Functional, metabolic, and morphological aspects of continuous, normothermic heart preservation: Effects of different preparation and perfusion techniques. Tissue Eng Part C Methods 2009; 15: 275.
    • (2009) Tissue Eng Part C Methods , vol.15 , pp. 275
    • Garbade, J.1    Krautz, C.2    Aupperle, H.3
  • 15
    • 0035502386 scopus 로고    scopus 로고
    • Hypothermia-A limiting factor in using warm ischaemically damaged kidneys
    • Brasile L, Stubenitsky BM, Booster MH, et al. Hypothermia-A limiting factor in using warm ischaemically damaged kidneys. Am J Transplant 2001; 1: 316.
    • (2001) Am J Transplant , vol.1 , pp. 316
    • Brasile, L.1    Stubenitsky, B.M.2    Booster, M.H.3
  • 16
    • 34249036433 scopus 로고    scopus 로고
    • First human transplantation of a nonacceptable donor lung after reconditioning ex vivo
    • Steen S, Ingemansson R, Eriksson L, et al. First human transplantation of a nonacceptable donor lung after reconditioning ex vivo. Ann Thorac Surg 2007; 83: 2191.
    • (2007) Ann Thorac Surg , vol.83 , pp. 2191
    • Steen, S.1    Ingemansson, R.2    Eriksson, L.3
  • 17
    • 79954566390 scopus 로고    scopus 로고
    • Normothermic ex vivo lung perfusion in clinical lung transplantation
    • Cypel M, Yeung JC, Liu M, et al. Normothermic ex vivo lung perfusion in clinical lung transplantation. N Engl J Med 2011; 364: 1431.
    • (2011) N Engl J Med , vol.364 , pp. 1431
    • Cypel, M.1    Yeung, J.C.2    Liu, M.3
  • 18


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.