1
-
-
57949086585
-
The myth of clinical precision
-
e1
-
Brandt JD. The myth of clinical precision. Ophthalmology 2009; 116:1-2; e1.
-
(2009)
Ophthalmology
, vol.116
, pp. 1-2
-
-
Brandt, J.D.1
-
2
-
-
70449195078
-
Über applanationstonometrie
-
Goldmann H, Schmidt T. Über applanationstonometrie. Ophthalmologica 1957; 134:221-242.
-
(1957)
Ophthalmologica
, vol.134
, pp. 221-242
-
-
Goldmann, H.1
Schmidt, T.2
-
3
-
-
0027291601
-
Sources of error with use of goldmann-type tonometers
-
Whitacre MM, Stein R. Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol 1993; 38:1-30.
-
(1993)
Surv Ophthalmol
, vol.38
, pp. 1-30
-
-
Whitacre, M.M.1
Stein, R.2
-
5
-
-
33645846918
-
Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry
-
Kohlhaas M, Boehm AG, Spoerl E, et al. Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry. Arch Ophthalmol 2006; 124:471-476.
-
(2006)
Arch Ophthalmol
, vol.124
, pp. 471-476
-
-
Kohlhaas, M.1
Boehm, A.G.2
Spoerl, E.3
-
6
-
-
0035163029
-
Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings
-
Feltgen N, Leifert D, Funk J. Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings. Br J Ophthalmol 2001; 85:85-87.
-
(2001)
Br J Ophthalmol
, vol.85
, pp. 85-87
-
-
Feltgen, N.1
Leifert, D.2
Funk, J.3
-
7
-
-
0035144705
-
Central corneal thickness of Caucasians and African Americans in glaucomatous and nonglaucomatous populations
-
La Rosa FA, Gross RL, Orengo-Nania S. Central corneal thickness of Caucasians and African Americans in glaucomatous and nonglaucomatous populations. Arch Ophthalmol 2001; 119:23-27.
-
(2001)
Arch Ophthalmol
, vol.119
, pp. 23-27
-
-
La Rosa, F.A.1
Gross, R.L.2
Orengo-Nania, S.3
-
8
-
-
0034803965
-
Central corneal thickness in the ocular hypertension treatment study (OHTS)
-
Brandt JD, Beiser JA, Kass MA, Gordon MO. Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS). Ophthalmology 2001; 108:1779-1788.
-
(2001)
Ophthalmology
, vol.108
, pp. 1779-1788
-
-
Brandt, J.D.1
Beiser, J.A.2
Kass, M.A.3
Gordon, M.O.4
-
9
-
-
0031807443
-
Central corneal thickness and intraocular pressure in a Mongolian population
-
Foster PJ, Baasanhu J, Alsbirk PH, et al. Central corneal thickness and intraocular pressure in a Mongolian population. Ophthalmology 1998; 105:969-973.
-
(1998)
Ophthalmology
, vol.105
, pp. 969-973
-
-
Foster, P.J.1
Baasanhu, J.2
Alsbirk, P.H.3
-
10
-
-
0032936567
-
Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma
-
Copt RP, Thomas R, Mermoud A. Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma. Arch Ophthalmol 1999; 117:14-16.
-
(1999)
Arch Ophthalmol
, vol.117
, pp. 14-16
-
-
Copt, R.P.1
Thomas, R.2
Mermoud, A.3
-
11
-
-
0016261804
-
Central corneal thickness in low-tension glaucoma
-
Ehlers N, Hansen FK. Central corneal thickness in low-tension glaucoma. Acta Ophthalmol (Copenh) 1974; 52:740-746.
-
(1974)
Acta Ophthalmol (Copenh)
, vol.52
, pp. 740-746
-
-
Ehlers, N.1
Hansen, F.K.2
-
12
-
-
0034603359
-
Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
-
Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 2000; 44:367-408.
-
(2000)
Surv Ophthalmol
, vol.44
, pp. 367-408
-
-
Doughty, M.J.1
Zaman, M.L.2
-
13
-
-
0036272299
-
The ocular hypertension treatment study: Baseline factors that predict the onset of primary open-angle glaucoma
-
Gordon MO, Beiser JA, Brandt JD, et al. The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol 2002; 120:714-720.
-
(2002)
Arch Ophthalmol
, vol.120
, pp. 714-720
-
-
Gordon, M.O.1
Beiser, J.A.2
Brandt, J.D.3
-
14
-
-
20144370874
-
Change in intraocular pressure measurements after LASIK: The effect of the refractive correction and the lamellar flap
-
Chang DH, Stulting RD. Change in intraocular pressure measurements after LASIK: the effect of the refractive correction and the lamellar flap. Ophthalmology 2005; 112:1009-1016.
-
(2005)
Ophthalmology
, vol.112
, pp. 1009-1016
-
-
Chang, D.H.1
Stulting, R.D.2
-
15
-
-
57949111404
-
Measurement of goldmann applanation tonometer calibration error
-
Choudhari NS, George R, Baskaran M, et al. Measurement of Goldmann applanation tonometer calibration error. Ophthalmology 2009; 116:3-8.
-
(2009)
Ophthalmology
, vol.116
, pp. 3-8
-
-
Choudhari, N.S.1
George, R.2
Baskaran, M.3
-
16
-
-
80053635005
-
Variability in the calibration error of the goldmann applanation tonometer
-
Choudhari NS, Jadhav V, George R, Vijaya L. Variability in the calibration error of the goldmann applanation tonometer. J Glaucoma 2011; 20:492-496.
-
(2011)
J Glaucoma
, vol.20
, pp. 492-496
-
-
Choudhari, N.S.1
Jadhav, V.2
George, R.3
Vijaya, L.4
-
17
-
-
21344460937
-
The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, noncontact tonometry, the tono-pen XL, and goldmann applanation tonometry
-
Tonnu PA, Ho T, Newson T, et al. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, noncontact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol 2005; 89:851-854.
-
(2005)
Br J Ophthalmol
, vol.89
, pp. 851-854
-
-
Tonnu, P.A.1
Ho, T.2
Newson, T.3
-
18
-
-
84855457936
-
IOP measured by dynamic contour tonometry correlates with IOP measured by goldmann applanation tonometry and noncontact tonometry in Japanese individuals
-
Ito K, Tawara A, Kubota T, Harada Y. IOP measured by dynamic contour tonometry correlates with IOP measured by Goldmann applanation tonometry and noncontact tonometry in Japanese individuals. J Glaucoma 2012; 21:35-40.
-
(2012)
J Glaucoma
, vol.21
, pp. 35-40
-
-
Ito, K.1
Tawara, A.2
Kubota, T.3
Harada, Y.4
-
19
-
-
18744368475
-
Measurement of intraocular pressure using the NT-4000: A new noncontact tonometer equipped with pulse synchronous measurement function
-
Yaoeda K, Shirakashi M, Fukushima A, et al. Measurement of intraocular pressure using the NT-4000: a new noncontact tonometer equipped with pulse synchronous measurement function. J Glaucoma 2005; 14:201-205.
-
(2005)
J Glaucoma
, vol.14
, pp. 201-205
-
-
Yaoeda, K.1
Shirakashi, M.2
Fukushima, A.3
-
20
-
-
84862571055
-
Comparison of intraocular pressure measurement between rebound, noncontact and goldmann applanation tonometry in treated glaucoma patients
-
Vincent SJ, Vincent RA, Shields D, Lee GA. Comparison of intraocular pressure measurement between rebound, noncontact and Goldmann applanation tonometry in treated glaucoma patients. Clin Exp Ophthalmol 2012; 40:e163-170.
-
(2012)
Clin Exp Ophthalmol
, vol.40
, pp. e163-170
-
-
Vincent, S.J.1
Vincent, R.A.2
Shields, D.3
Lee, G.A.4
-
21
-
-
79955611374
-
Repeatability of intraocular pressure and central corneal thickness measurements provided by a noncontact method of tonometry and pachymetry
-
Schiano Lomoriello D, Lombardo M, Tranchina L, et al. Repeatability of intraocular pressure and central corneal thickness measurements provided by a noncontact method of tonometry and pachymetry. Graefes Arch Clin Exp Ophthalmol 2011; 249:429-434.
-
(2011)
Graefes Arch Clin Exp Ophthalmol
, vol.249
, pp. 429-434
-
-
Schiano Lomoriello, D.1
Lombardo, M.2
Tranchina, L.3
-
22
-
-
35848966791
-
What biomechanical properties of the cornea are relevant for the clinician?
-
Kotecha A. What biomechanical properties of the cornea are relevant for the clinician? Surv Ophthalmol 2007; 52 (Suppl 2):S109-S114.
-
(2007)
Surv Ophthalmol
, vol.52
, pp. S109-S114
-
-
Kotecha, A.1
-
23
-
-
84881667084
-
Factors influencing intermethod agreement between goldmann applanation, pascal dynamic contour, and ocular response analyzer tonometry
-
Sullivan-Mee M, Lewis SE, Pensyl D, et al. Factors influencing intermethod agreement between goldmann applanation, pascal dynamic contour, and ocular response analyzer tonometry. J Glaucoma 2013; 22:487-495.
-
(2013)
J Glaucoma
, vol.22
, pp. 487-495
-
-
Sullivan-Mee, M.1
Lewis, S.E.2
Pensyl, D.3
-
24
-
-
77949658771
-
Intraocular pressure measurement precision with the goldmann applanation, dynamic contour, and ocular response analyzer tonometers
-
Kotecha A, White E, Schlottmann PG, Garway-Heath DF. Intraocular pressure measurement precision with the Goldmann applanation, dynamic contour, and ocular response analyzer tonometers. Ophthalmology 2010; 117:730-737.
-
(2010)
Ophthalmology
, vol.117
, pp. 730-737
-
-
Kotecha, A.1
White, E.2
Schlottmann, P.G.3
Garway-Heath, D.F.4
-
25
-
-
74549215576
-
Repeatability and reproducibility for intraocular pressure measurement by dynamic contour, ocular response analyzer, and goldmann applanation tonometry
-
Sullivan-Mee M, Gerhardt G, Halverson KD, Qualls C. Repeatability and reproducibility for intraocular pressure measurement by dynamic contour, ocular response analyzer, and goldmann applanation tonometry. J Glaucoma 2009; 18:666-673.
-
(2009)
J Glaucoma
, vol.18
, pp. 666-673
-
-
Sullivan-Mee, M.1
Gerhardt, G.2
Halverson, K.D.3
Qualls, C.4
-
26
-
-
80051795602
-
Influence of ocular pulse amplitude on ocular response analyzer measurements
-
Xu G, Lam DS, Leung CK. Influence of ocular pulse amplitude on ocular response analyzer measurements. J Glaucoma 2011; 20:344-349.
-
(2011)
J Glaucoma
, vol.20
, pp. 344-349
-
-
Xu, G.1
Lam, D.S.2
Leung, C.K.3
-
27
-
-
84859425772
-
Lower corneal hysteresis is associated with more rapid glaucomatous visual field progression
-
De Moraes CV, Hill V, Tello C, et al. Lower corneal hysteresis is associated with more rapid glaucomatous visual field progression. J Glaucoma 2012; 21:209-213.
-
(2012)
J Glaucoma
, vol.21
, pp. 209-213
-
-
De Moraes, C.V.1
Hill, V.2
Tello, C.3
-
28
-
-
79955979469
-
Corneal hysteresis and visual field asymmetry in open angle glaucoma
-
Anand A, De Moraes CG, Teng CC, et al. Corneal hysteresis and visual field asymmetry in open angle glaucoma. Invest Ophthalmol Vis Sci 2010; 51:6514-6518.
-
(2010)
Invest Ophthalmol Vis Sci
, vol.51
, pp. 6514-6518
-
-
Anand, A.1
De Moraes, C.G.2
Teng, C.C.3
-
29
-
-
84873825674
-
The heritability of glaucoma-related traits corneal hysteresis, central corneal thickness, intraocular pressure, and choroidal blood flow pulsatility
-
Freeman EE, Roy-Gagnon MH, Descovich D, et al. The heritability of glaucoma-related traits corneal hysteresis, central corneal thickness, intraocular pressure, and choroidal blood flow pulsatility. PLoS One 2013; 8:e55573.
-
(2013)
PLoS One
, vol.8
-
-
Freeman, E.E.1
Roy-Gagnon, M.H.2
Descovich, D.3
-
30
-
-
46949110019
-
Corneal hysteresis and corneal resistance factor in keratoectasia: Findings using the reichert ocular response analyzer
-
Kirwan C, O'Malley D, O'Keefe M. Corneal hysteresis and corneal resistance factor in keratoectasia: findings using the Reichert ocular response analyzer. Ophthalmologica 2008; 222:334-337.
-
(2008)
Ophthalmologica
, vol.222
, pp. 334-337
-
-
Kirwan, C.1
O'Malley, D.2
O'Keefe, M.3
-
31
-
-
57149087528
-
Accuracy of goldmann, ocular response analyser, pascal and TonoPen XL tonometry in keratoconic and normal eyes
-
Mollan SP, Wolffsohn JS, Nessim M, et al. Accuracy of Goldmann, ocular response analyser, Pascal and TonoPen XL tonometry in keratoconic and normal eyes. Br J Ophthalmol 2008; 92:1661-1665.
-
(2008)
Br J Ophthalmol
, vol.92
, pp. 1661-1665
-
-
Mollan, S.P.1
Wolffsohn, J.S.2
Nessim, M.3
-
32
-
-
25644460363
-
Dynamic contour tonometry: Presentation of a new tonometer
-
Kanngiesser HE, Kniestedt C, Robert YC. Dynamic contour tonometry: presentation of a new tonometer. J Glaucoma 2005; 14:344-350.
-
(2005)
J Glaucoma
, vol.14
, pp. 344-350
-
-
Kanngiesser, H.E.1
Kniestedt, C.2
Robert, Y.C.3
-
33
-
-
3042667876
-
Dynamic contour tonometry for post-LASIK intraocular pressure measurements
-
Duba I, Wirthlin AC. Dynamic contour tonometry for post-LASIK intraocular pressure measurements. Klin Monatsbl Augenheilkd 2004; 221:347-350.
-
(2004)
Klin Monatsbl Augenheilkd
, vol.221
, pp. 347-350
-
-
Duba, I.1
Wirthlin, A.C.2
-
34
-
-
0041360373
-
Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis
-
Kaufmann C, Bachmann LM, Thiel MA. Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis. Invest Ophthalmol Vis Sci 2003; 44:3790-3794.
-
(2003)
Invest Ophthalmol Vis Sci
, vol.44
, pp. 3790-3794
-
-
Kaufmann, C.1
Bachmann, L.M.2
Thiel, M.A.3
-
35
-
-
38349084770
-
Comparison of dynamic contour tonometry and goldmann applanation tonometry in deep lamellar and penetrating keratoplasties
-
Ceruti P, Morbio R, Marraffa M, Marchini G. Comparison of dynamic contour tonometry and goldmann applanation tonometry in deep lamellar and penetrating keratoplasties. Am J Ophthalmol 2008; 145:215-221.
-
(2008)
Am J Ophthalmol
, vol.145
, pp. 215-221
-
-
Ceruti, P.1
Morbio, R.2
Marraffa, M.3
Marchini, G.4
-
36
-
-
84879438625
-
Repeatability and reproducibility of goldmann applanation, dynamic contour, and ocular response analyzer tonometry
-
Wang AS, Alencar LM, Weinreb RN, et al. Repeatability and Reproducibility of Goldmann Applanation, Dynamic Contour, and Ocular Response Analyzer Tonometry. J Glaucoma 2013; 22:127-132.
-
(2013)
J Glaucoma
, vol.22
, pp. 127-132
-
-
Wang, A.S.1
Alencar, L.M.2
Weinreb, R.N.3
-
37
-
-
84879180318
-
Comparison of the utility of pascal dynamic contour tonometry with goldmann applanation tonometry in routine clinical practice
-
Anderson MF, Agius-Fernandez A, Kaye SB. Comparison of the utility of Pascal dynamic contour tonometry with Goldmann applanation tonometry in routine clinical practice. J Glaucoma 2013; 22:422-426.
-
(2013)
J Glaucoma
, vol.22
, pp. 422-426
-
-
Anderson, M.F.1
Agius-Fernandez, A.2
Kaye, S.B.3
-
38
-
-
0008704458
-
Automatic tonometer with exact theory: Various biological applications
-
Mackay RS, Marg E, Oechsli R. Automatic tonometer with exact theory: various biological applications. Science 1960; 131:1668-1669.
-
(1960)
Science
, vol.131
, pp. 1668-1669
-
-
Mackay, R.S.1
Marg, E.2
Oechsli, R.3
-
39
-
-
79952744549
-
Comparison of goldmann applanation tonometer, noncontact tonometer, and TonoPen XL for intraocular pressure measurement in different types of glaucomatous, ocular hypertensive, and normal eyes
-
Kim NR, Kim CY, Kim H, et al. Comparison of goldmann applanation tonometer, noncontact tonometer, and TonoPen XL for intraocular pressure measurement in different types of glaucomatous, ocular hypertensive, and normal eyes. Curr Eye Res 2011; 36:295-300.
-
(2011)
Curr Eye Res
, vol.36
, pp. 295-300
-
-
Kim, N.R.1
Kim, C.Y.2
Kim, H.3
-
40
-
-
0035091093
-
New tonopen XL: Comparison with the goldmann tonometer
-
Iester M, Mermoud A, Achache F, Roy S. New Tonopen XL: comparison with the Goldmann tonometer. Eye (Lond) 2001; 15:52-58.
-
(2001)
Eye (Lond)
, vol.15
, pp. 52-58
-
-
Iester, M.1
Mermoud, A.2
Achache, F.3
Roy, S.4
-
41
-
-
33746350421
-
Central and peripheral corneal thickness: Influence on the iop measurement by tonopen
-
Amaral WO, Teixeira RM, Alencar LM, et al. Central and peripheral corneal thickness: influence on the iop measurement by Tonopen. Arq Bras Oftalmol 2006; 69:41-45.
-
(2006)
Arq Bras Oftalmol
, vol.69
, pp. 41-45
-
-
Amaral, W.O.1
Teixeira, R.M.2
Alencar, L.M.3
-
42
-
-
78549269739
-
Transpalpebral measurement of intraocular pressure using the diaton tonometer versus standard goldmann applanation tonometry
-
Li Y, Shi J, Duan X, Fan F. Transpalpebral measurement of intraocular pressure using the Diaton tonometer versus standard Goldmann applanation tonometry. Graefes Arch Clin Exp Ophthalmol 2010; 248:1765-1770.
-
(2010)
Graefes Arch Clin Exp Ophthalmol
, vol.248
, pp. 1765-1770
-
-
Li, Y.1
Shi, J.2
Duan, X.3
Fan, F.4
-
44
-
-
84862558129
-
Diaton tonometry: An assessment of validity and preference against goldmann tonometry
-
Doherty MD, Carrim ZI, O'Neill DP. Diaton tonometry: an assessment of validity and preference against Goldmann tonometry. Clin Exp Ophthalmol 2012; 40:e171-e175.
-
(2012)
Clin Exp Ophthalmol
, vol.40
, pp. e171-e175
-
-
Doherty, M.D.1
Carrim, Z.I.2
O'Neill, D.P.3
-
45
-
-
84863317154
-
Comparative evaluation of diaton and goldmann applanation tonometers
-
Bali SJ, Bhartiya S, Sobti A, et al. Comparative evaluation of Diaton and Goldmann applanation tonometers. Ophthalmologica 2012; 228:42-46.
-
(2012)
Ophthalmologica
, vol.228
, pp. 42-46
-
-
Bali, S.J.1
Bhartiya, S.2
Sobti, A.3
-
46
-
-
0034115306
-
A new induction-based impact method for measuring intraocular pressure
-
Kontiola AI. A new induction-based impact method for measuring intraocular pressure. Acta Ophthalmol Scand 2000; 78:142-145.
-
(2000)
Acta Ophthalmol Scand
, vol.78
, pp. 142-145
-
-
Kontiola, A.I.1
-
47
-
-
0030318702
-
A new electromechanical method for measuring intraocular pressure
-
Kontiola A. A new electromechanical method for measuring intraocular pressure. Doc Ophthalmol 1996; 93:265-276.
-
(1996)
Doc Ophthalmol
, vol.93
, pp. 265-276
-
-
Kontiola, A.1
-
48
-
-
34247633160
-
Reproducibility and tolerability of the ICare rebound tonometerinschool children
-
Sahin A, Basmak H, Niyaz L, Yildirim N. Reproducibility and tolerability of the ICare rebound tonometerinschool children. JGlaucoma 2007; 16:185-188.
-
(2007)
JGlaucoma
, vol.16
, pp. 185-188
-
-
Sahin, A.1
Basmak, H.2
Niyaz, L.3
Yildirim, N.4
-
49
-
-
28244452880
-
Comparison of the ICare rebound tonometer with the goldmann tonometer in a normal population
-
Fernandes P, Diaz-Rey JA, Queiros A, et al. Comparison of the ICare rebound tonometer with the Goldmann tonometer in a normal population. Ophthalmic Physiol Opt 2005; 25:436-440.
-
(2005)
Ophthalmic Physiol Opt
, vol.25
, pp. 436-440
-
-
Fernandes, P.1
Diaz-Rey, J.A.2
Queiros, A.3
-
50
-
-
34447631350
-
Comparison of the rebound tonometer with the goldmann applanation tonometer in glaucoma patients
-
Sahin A, Niyaz L, Yildirim N. Comparison of the rebound tonometer with the Goldmann applanation tonometer in glaucoma patients. Clin Exp Ophthalmol 2007; 35:335-339.
-
(2007)
Clin Exp Ophthalmol
, vol.35
, pp. 335-339
-
-
Sahin, A.1
Niyaz, L.2
Yildirim, N.3
-
51
-
-
84877749079
-
Comparison of handheld rebound tonometry with goldmann applanation tonometry in children with glaucoma: A cohort study
-
Dahlmann-Noor AH, Puertas R, Tabasa-Lim S, et al. Comparison of handheld rebound tonometry with Goldmann applanation tonometry in children with glaucoma: a cohort study. BMJ Open 2013; 3:e001788.
-
(2013)
BMJ Open
, vol.3
-
-
Dahlmann-Noor, A.H.1
Puertas, R.2
Tabasa-Lim, S.3
-
52
-
-
78651425786
-
Comparison of ICare rebound tonometer with noncontact tonometer in healthy children
-
Kageyama M, Hirooka K, Baba T, Shiraga F. Comparison of ICare rebound tonometer with noncontact tonometer in healthy children. J Glaucoma 2011; 20:63-66.
-
(2011)
J Glaucoma
, vol.20
, pp. 63-66
-
-
Kageyama, M.1
Hirooka, K.2
Baba, T.3
Shiraga, F.4
-
53
-
-
79956189255
-
Icare rebound tonometry in children with known and suspected glaucoma
-
Flemmons MS, Hsiao YC, Dzau J, et al. Icare rebound tonometry in children with known and suspected glaucoma. J AAPOS 2011; 15:153-157.
-
(2011)
J AAPOS
, vol.15
, pp. 153-157
-
-
Flemmons, M.S.1
Hsiao, Y.C.2
Dzau, J.3
-
54
-
-
84875734672
-
Rebound tonometry in children: A report by the American academy of ophthalmology
-
Lambert SR, Melia M, Buffenn AN, et al. Rebound tonometry in children: a report by the American Academy of Ophthalmology. Ophthalmology 2013; 120:e21-e27.
-
(2013)
Ophthalmology
, vol.120
, pp. e21-e27
-
-
Lambert, S.R.1
Melia, M.2
Buffenn, A.N.3
-
55
-
-
84899435700
-
Assessment of IcareONE rebound tonometer for self-measuring intraocular pressure
-
Sakamoto M, Kanamori A, Fujihara M, et al. Assessment of IcareONE rebound tonometer for self-measuring intraocular pressure. Acta Ophthalmol 2014; 92:243-248.
-
(2014)
Acta Ophthalmol
, vol.92
, pp. 243-248
-
-
Sakamoto, M.1
Kanamori, A.2
Fujihara, M.3
-
56
-
-
84942190768
-
Clinical evaluation of the new rebound tonometers icare PRO and icare ONE compared with the goldmann tonometer
-
[Epub on Journal website, no further details of publication]
-
Moreno-Montanes J, Martinez-de-la-Casa JM, Sabater AL, et al. Clinical Evaluation of the New Rebound Tonometers Icare PRO and Icare ONE Compared With the Goldmann Tonometer. J Glaucoma 2014. [Epub on Journal website, no further details of publication]
-
(2014)
J Glaucoma
-
-
Moreno-Montanes, J.1
Martinez-De-La-Casa, J.M.2
Sabater, A.L.3
-
57
-
-
84864151636
-
Icare ONE rebound versus goldmann applanation tonometry in children with known or suspected glaucoma
-
e1
-
Gandhi NG, Prakalapakorn SG, El-Dairi MA, et al. Icare ONE rebound versus Goldmann applanation tonometry in children with known or suspected glaucoma. Am J Ophthalmol 2012; 154:843-849; e1.
-
(2012)
Am J Ophthalmol
, vol.154
, pp. 843-849
-
-
Gandhi, N.G.1
Prakalapakorn, S.G.2
El-Dairi, M.A.3
-
58
-
-
66249135995
-
Wireless contact lens sensor for intraocular pressure monitoring: Assessment on enucleated pig eyes
-
Leonardi M, Pitchon EM, Bertsch A, et al. Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes. Acta Ophthalmol 2009; 87:433-437.
-
(2009)
Acta Ophthalmol
, vol.87
, pp. 433-437
-
-
Leonardi, M.1
Pitchon, E.M.2
Bertsch, A.3
-
59
-
-
79955031844
-
Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: Initial clinical experience in patients with open angle glaucoma
-
Mansouri K, Shaarawy T. Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma. Br J Ophthalmol 2011; 95:627-629.
-
(2011)
Br J Ophthalmol
, vol.95
, pp. 627-629
-
-
Mansouri, K.1
Shaarawy, T.2
-
60
-
-
84871203646
-
Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: Safety, tolerability, and reproducibility in patients with glaucoma
-
Mansouri K, Medeiros FA, Tafreshi A, Weinreb RN. Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma. Arch Ophthalmol 2012; 130:1534-1539.
-
(2012)
Arch Ophthalmol
, vol.130
, pp. 1534-1539
-
-
Mansouri, K.1
Medeiros, F.A.2
Tafreshi, A.3
Weinreb, R.N.4
-
61
-
-
84891868131
-
Evaluation of continuous 24-h intraocular pressure monitoring for assessment of prostaglandin-induced pressure reduction in glaucoma
-
Hollo G, Kothy P, Vargha P. Evaluation of continuous 24-h intraocular pressure monitoring for assessment of prostaglandin-induced pressure reduction in glaucoma. J Glaucoma 2014; 23:e6-e12.
-
(2014)
J Glaucoma
, vol.23
, pp. e6-e12
-
-
Hollo, G.1
Kothy, P.2
Vargha, P.3
-
62
-
-
84908112476
-
An implantable intraocular pressure transducer: Initial safety outcomes
-
Melki S, Todani A, Cherfan G. An implantable intraocular pressure transducer: initial safety outcomes. J Am Med Assoc Ophthalmol 2014; 132:1221-1225.
-
(2014)
J Am Med Assoc Ophthalmol
, vol.132
, pp. 1221-1225
-
-
Melki, S.1
Todani, A.2
Cherfan, G.3
|