Measuring intraocular pressure

Author keywords

Central corneal thickness; Corneal hysteresis; Glaucoma; Intraocular pressure; Tonometry

Indexed keywords

ANALYZER; APPLANATION TONOMETER; DYNAMIC CONTOUR TONOMETRY; DYNAMICS; GOLDMANN APPLANATION TONOMETRY; HAND HELD TONOMETRY DEVICE; HUMAN; INTRAOCULAR PRESSURE; MACKAY MARG APPLANATION TONOMETRY; MEDICAL TECHNOLOGY; NONHUMAN; OCULAR RESPONSE ANALYZER; PRESSURE TRANSDUCER; PRIORITY JOURNAL; REBOUND TONOMETRY; REVIEW; TONOMETRY; TRANSPALPEBRAL TONOMETRY; TWENTY FOUR HOUR CONTINUOUS TONOMETRY; WIRELESS INTRAOCULAR PRESSURE TRANSDUCER; CORNEA; DEVICES; ELASTICITY; GLAUCOMA; OCULOPLETHYSMOGRAPHY; PHYSIOLOGY;

EID: 84926213545     PISSN: 10408738     EISSN: 15317021     Source Type: Journal    
DOI: 10.1097/ICU.0000000000000129     Document Type: Review
Times cited : (59)

References (62)
  • 1
    • 57949086585 scopus 로고    scopus 로고
    • The myth of clinical precision
    • e1
    • Brandt JD. The myth of clinical precision. Ophthalmology 2009; 116:1-2; e1.
    • (2009) Ophthalmology , vol.116 , pp. 1-2
    • Brandt, J.D.1
  • 2
    • 70449195078 scopus 로고
    • Über applanationstonometrie
    • Goldmann H, Schmidt T. Über applanationstonometrie. Ophthalmologica 1957; 134:221-242.
    • (1957) Ophthalmologica , vol.134 , pp. 221-242
    • Goldmann, H.1    Schmidt, T.2
  • 3
    • 0027291601 scopus 로고
    • Sources of error with use of goldmann-type tonometers
    • Whitacre MM, Stein R. Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol 1993; 38:1-30.
    • (1993) Surv Ophthalmol , vol.38 , pp. 1-30
    • Whitacre, M.M.1    Stein, R.2
  • 5
    • 33645846918 scopus 로고    scopus 로고
    • Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry
    • Kohlhaas M, Boehm AG, Spoerl E, et al. Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry. Arch Ophthalmol 2006; 124:471-476.
    • (2006) Arch Ophthalmol , vol.124 , pp. 471-476
    • Kohlhaas, M.1    Boehm, A.G.2    Spoerl, E.3
  • 6
    • 0035163029 scopus 로고    scopus 로고
    • Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings
    • Feltgen N, Leifert D, Funk J. Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings. Br J Ophthalmol 2001; 85:85-87.
    • (2001) Br J Ophthalmol , vol.85 , pp. 85-87
    • Feltgen, N.1    Leifert, D.2    Funk, J.3
  • 7
    • 0035144705 scopus 로고    scopus 로고
    • Central corneal thickness of Caucasians and African Americans in glaucomatous and nonglaucomatous populations
    • La Rosa FA, Gross RL, Orengo-Nania S. Central corneal thickness of Caucasians and African Americans in glaucomatous and nonglaucomatous populations. Arch Ophthalmol 2001; 119:23-27.
    • (2001) Arch Ophthalmol , vol.119 , pp. 23-27
    • La Rosa, F.A.1    Gross, R.L.2    Orengo-Nania, S.3
  • 8
    • 0034803965 scopus 로고    scopus 로고
    • Central corneal thickness in the ocular hypertension treatment study (OHTS)
    • Brandt JD, Beiser JA, Kass MA, Gordon MO. Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS). Ophthalmology 2001; 108:1779-1788.
    • (2001) Ophthalmology , vol.108 , pp. 1779-1788
    • Brandt, J.D.1    Beiser, J.A.2    Kass, M.A.3    Gordon, M.O.4
  • 9
    • 0031807443 scopus 로고    scopus 로고
    • Central corneal thickness and intraocular pressure in a Mongolian population
    • Foster PJ, Baasanhu J, Alsbirk PH, et al. Central corneal thickness and intraocular pressure in a Mongolian population. Ophthalmology 1998; 105:969-973.
    • (1998) Ophthalmology , vol.105 , pp. 969-973
    • Foster, P.J.1    Baasanhu, J.2    Alsbirk, P.H.3
  • 10
    • 0032936567 scopus 로고    scopus 로고
    • Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma
    • Copt RP, Thomas R, Mermoud A. Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma. Arch Ophthalmol 1999; 117:14-16.
    • (1999) Arch Ophthalmol , vol.117 , pp. 14-16
    • Copt, R.P.1    Thomas, R.2    Mermoud, A.3
  • 11
    • 0016261804 scopus 로고
    • Central corneal thickness in low-tension glaucoma
    • Ehlers N, Hansen FK. Central corneal thickness in low-tension glaucoma. Acta Ophthalmol (Copenh) 1974; 52:740-746.
    • (1974) Acta Ophthalmol (Copenh) , vol.52 , pp. 740-746
    • Ehlers, N.1    Hansen, F.K.2
  • 12
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 2000; 44:367-408.
    • (2000) Surv Ophthalmol , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 13
    • 0036272299 scopus 로고    scopus 로고
    • The ocular hypertension treatment study: Baseline factors that predict the onset of primary open-angle glaucoma
    • Gordon MO, Beiser JA, Brandt JD, et al. The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol 2002; 120:714-720.
    • (2002) Arch Ophthalmol , vol.120 , pp. 714-720
    • Gordon, M.O.1    Beiser, J.A.2    Brandt, J.D.3
  • 14
    • 20144370874 scopus 로고    scopus 로고
    • Change in intraocular pressure measurements after LASIK: The effect of the refractive correction and the lamellar flap
    • Chang DH, Stulting RD. Change in intraocular pressure measurements after LASIK: the effect of the refractive correction and the lamellar flap. Ophthalmology 2005; 112:1009-1016.
    • (2005) Ophthalmology , vol.112 , pp. 1009-1016
    • Chang, D.H.1    Stulting, R.D.2
  • 15
    • 57949111404 scopus 로고    scopus 로고
    • Measurement of goldmann applanation tonometer calibration error
    • Choudhari NS, George R, Baskaran M, et al. Measurement of Goldmann applanation tonometer calibration error. Ophthalmology 2009; 116:3-8.
    • (2009) Ophthalmology , vol.116 , pp. 3-8
    • Choudhari, N.S.1    George, R.2    Baskaran, M.3
  • 16
    • 80053635005 scopus 로고    scopus 로고
    • Variability in the calibration error of the goldmann applanation tonometer
    • Choudhari NS, Jadhav V, George R, Vijaya L. Variability in the calibration error of the goldmann applanation tonometer. J Glaucoma 2011; 20:492-496.
    • (2011) J Glaucoma , vol.20 , pp. 492-496
    • Choudhari, N.S.1    Jadhav, V.2    George, R.3    Vijaya, L.4
  • 17
    • 21344460937 scopus 로고    scopus 로고
    • The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, noncontact tonometry, the tono-pen XL, and goldmann applanation tonometry
    • Tonnu PA, Ho T, Newson T, et al. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, noncontact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol 2005; 89:851-854.
    • (2005) Br J Ophthalmol , vol.89 , pp. 851-854
    • Tonnu, P.A.1    Ho, T.2    Newson, T.3
  • 18
    • 84855457936 scopus 로고    scopus 로고
    • IOP measured by dynamic contour tonometry correlates with IOP measured by goldmann applanation tonometry and noncontact tonometry in Japanese individuals
    • Ito K, Tawara A, Kubota T, Harada Y. IOP measured by dynamic contour tonometry correlates with IOP measured by Goldmann applanation tonometry and noncontact tonometry in Japanese individuals. J Glaucoma 2012; 21:35-40.
    • (2012) J Glaucoma , vol.21 , pp. 35-40
    • Ito, K.1    Tawara, A.2    Kubota, T.3    Harada, Y.4
  • 19
    • 18744368475 scopus 로고    scopus 로고
    • Measurement of intraocular pressure using the NT-4000: A new noncontact tonometer equipped with pulse synchronous measurement function
    • Yaoeda K, Shirakashi M, Fukushima A, et al. Measurement of intraocular pressure using the NT-4000: a new noncontact tonometer equipped with pulse synchronous measurement function. J Glaucoma 2005; 14:201-205.
    • (2005) J Glaucoma , vol.14 , pp. 201-205
    • Yaoeda, K.1    Shirakashi, M.2    Fukushima, A.3
  • 20
    • 84862571055 scopus 로고    scopus 로고
    • Comparison of intraocular pressure measurement between rebound, noncontact and goldmann applanation tonometry in treated glaucoma patients
    • Vincent SJ, Vincent RA, Shields D, Lee GA. Comparison of intraocular pressure measurement between rebound, noncontact and Goldmann applanation tonometry in treated glaucoma patients. Clin Exp Ophthalmol 2012; 40:e163-170.
    • (2012) Clin Exp Ophthalmol , vol.40 , pp. e163-170
    • Vincent, S.J.1    Vincent, R.A.2    Shields, D.3    Lee, G.A.4
  • 21
    • 79955611374 scopus 로고    scopus 로고
    • Repeatability of intraocular pressure and central corneal thickness measurements provided by a noncontact method of tonometry and pachymetry
    • Schiano Lomoriello D, Lombardo M, Tranchina L, et al. Repeatability of intraocular pressure and central corneal thickness measurements provided by a noncontact method of tonometry and pachymetry. Graefes Arch Clin Exp Ophthalmol 2011; 249:429-434.
    • (2011) Graefes Arch Clin Exp Ophthalmol , vol.249 , pp. 429-434
    • Schiano Lomoriello, D.1    Lombardo, M.2    Tranchina, L.3
  • 22
    • 35848966791 scopus 로고    scopus 로고
    • What biomechanical properties of the cornea are relevant for the clinician?
    • Kotecha A. What biomechanical properties of the cornea are relevant for the clinician? Surv Ophthalmol 2007; 52 (Suppl 2):S109-S114.
    • (2007) Surv Ophthalmol , vol.52 , pp. S109-S114
    • Kotecha, A.1
  • 23
    • 84881667084 scopus 로고    scopus 로고
    • Factors influencing intermethod agreement between goldmann applanation, pascal dynamic contour, and ocular response analyzer tonometry
    • Sullivan-Mee M, Lewis SE, Pensyl D, et al. Factors influencing intermethod agreement between goldmann applanation, pascal dynamic contour, and ocular response analyzer tonometry. J Glaucoma 2013; 22:487-495.
    • (2013) J Glaucoma , vol.22 , pp. 487-495
    • Sullivan-Mee, M.1    Lewis, S.E.2    Pensyl, D.3
  • 24
    • 77949658771 scopus 로고    scopus 로고
    • Intraocular pressure measurement precision with the goldmann applanation, dynamic contour, and ocular response analyzer tonometers
    • Kotecha A, White E, Schlottmann PG, Garway-Heath DF. Intraocular pressure measurement precision with the Goldmann applanation, dynamic contour, and ocular response analyzer tonometers. Ophthalmology 2010; 117:730-737.
    • (2010) Ophthalmology , vol.117 , pp. 730-737
    • Kotecha, A.1    White, E.2    Schlottmann, P.G.3    Garway-Heath, D.F.4
  • 25
    • 74549215576 scopus 로고    scopus 로고
    • Repeatability and reproducibility for intraocular pressure measurement by dynamic contour, ocular response analyzer, and goldmann applanation tonometry
    • Sullivan-Mee M, Gerhardt G, Halverson KD, Qualls C. Repeatability and reproducibility for intraocular pressure measurement by dynamic contour, ocular response analyzer, and goldmann applanation tonometry. J Glaucoma 2009; 18:666-673.
    • (2009) J Glaucoma , vol.18 , pp. 666-673
    • Sullivan-Mee, M.1    Gerhardt, G.2    Halverson, K.D.3    Qualls, C.4
  • 26
    • 80051795602 scopus 로고    scopus 로고
    • Influence of ocular pulse amplitude on ocular response analyzer measurements
    • Xu G, Lam DS, Leung CK. Influence of ocular pulse amplitude on ocular response analyzer measurements. J Glaucoma 2011; 20:344-349.
    • (2011) J Glaucoma , vol.20 , pp. 344-349
    • Xu, G.1    Lam, D.S.2    Leung, C.K.3
  • 27
    • 84859425772 scopus 로고    scopus 로고
    • Lower corneal hysteresis is associated with more rapid glaucomatous visual field progression
    • De Moraes CV, Hill V, Tello C, et al. Lower corneal hysteresis is associated with more rapid glaucomatous visual field progression. J Glaucoma 2012; 21:209-213.
    • (2012) J Glaucoma , vol.21 , pp. 209-213
    • De Moraes, C.V.1    Hill, V.2    Tello, C.3
  • 28
    • 79955979469 scopus 로고    scopus 로고
    • Corneal hysteresis and visual field asymmetry in open angle glaucoma
    • Anand A, De Moraes CG, Teng CC, et al. Corneal hysteresis and visual field asymmetry in open angle glaucoma. Invest Ophthalmol Vis Sci 2010; 51:6514-6518.
    • (2010) Invest Ophthalmol Vis Sci , vol.51 , pp. 6514-6518
    • Anand, A.1    De Moraes, C.G.2    Teng, C.C.3
  • 29
    • 84873825674 scopus 로고    scopus 로고
    • The heritability of glaucoma-related traits corneal hysteresis, central corneal thickness, intraocular pressure, and choroidal blood flow pulsatility
    • Freeman EE, Roy-Gagnon MH, Descovich D, et al. The heritability of glaucoma-related traits corneal hysteresis, central corneal thickness, intraocular pressure, and choroidal blood flow pulsatility. PLoS One 2013; 8:e55573.
    • (2013) PLoS One , vol.8
    • Freeman, E.E.1    Roy-Gagnon, M.H.2    Descovich, D.3
  • 30
    • 46949110019 scopus 로고    scopus 로고
    • Corneal hysteresis and corneal resistance factor in keratoectasia: Findings using the reichert ocular response analyzer
    • Kirwan C, O'Malley D, O'Keefe M. Corneal hysteresis and corneal resistance factor in keratoectasia: findings using the Reichert ocular response analyzer. Ophthalmologica 2008; 222:334-337.
    • (2008) Ophthalmologica , vol.222 , pp. 334-337
    • Kirwan, C.1    O'Malley, D.2    O'Keefe, M.3
  • 31
    • 57149087528 scopus 로고    scopus 로고
    • Accuracy of goldmann, ocular response analyser, pascal and TonoPen XL tonometry in keratoconic and normal eyes
    • Mollan SP, Wolffsohn JS, Nessim M, et al. Accuracy of Goldmann, ocular response analyser, Pascal and TonoPen XL tonometry in keratoconic and normal eyes. Br J Ophthalmol 2008; 92:1661-1665.
    • (2008) Br J Ophthalmol , vol.92 , pp. 1661-1665
    • Mollan, S.P.1    Wolffsohn, J.S.2    Nessim, M.3
  • 32
    • 25644460363 scopus 로고    scopus 로고
    • Dynamic contour tonometry: Presentation of a new tonometer
    • Kanngiesser HE, Kniestedt C, Robert YC. Dynamic contour tonometry: presentation of a new tonometer. J Glaucoma 2005; 14:344-350.
    • (2005) J Glaucoma , vol.14 , pp. 344-350
    • Kanngiesser, H.E.1    Kniestedt, C.2    Robert, Y.C.3
  • 33
    • 3042667876 scopus 로고    scopus 로고
    • Dynamic contour tonometry for post-LASIK intraocular pressure measurements
    • Duba I, Wirthlin AC. Dynamic contour tonometry for post-LASIK intraocular pressure measurements. Klin Monatsbl Augenheilkd 2004; 221:347-350.
    • (2004) Klin Monatsbl Augenheilkd , vol.221 , pp. 347-350
    • Duba, I.1    Wirthlin, A.C.2
  • 34
    • 0041360373 scopus 로고    scopus 로고
    • Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis
    • Kaufmann C, Bachmann LM, Thiel MA. Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis. Invest Ophthalmol Vis Sci 2003; 44:3790-3794.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 3790-3794
    • Kaufmann, C.1    Bachmann, L.M.2    Thiel, M.A.3
  • 35
    • 38349084770 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry and goldmann applanation tonometry in deep lamellar and penetrating keratoplasties
    • Ceruti P, Morbio R, Marraffa M, Marchini G. Comparison of dynamic contour tonometry and goldmann applanation tonometry in deep lamellar and penetrating keratoplasties. Am J Ophthalmol 2008; 145:215-221.
    • (2008) Am J Ophthalmol , vol.145 , pp. 215-221
    • Ceruti, P.1    Morbio, R.2    Marraffa, M.3    Marchini, G.4
  • 36
    • 84879438625 scopus 로고    scopus 로고
    • Repeatability and reproducibility of goldmann applanation, dynamic contour, and ocular response analyzer tonometry
    • Wang AS, Alencar LM, Weinreb RN, et al. Repeatability and Reproducibility of Goldmann Applanation, Dynamic Contour, and Ocular Response Analyzer Tonometry. J Glaucoma 2013; 22:127-132.
    • (2013) J Glaucoma , vol.22 , pp. 127-132
    • Wang, A.S.1    Alencar, L.M.2    Weinreb, R.N.3
  • 37
    • 84879180318 scopus 로고    scopus 로고
    • Comparison of the utility of pascal dynamic contour tonometry with goldmann applanation tonometry in routine clinical practice
    • Anderson MF, Agius-Fernandez A, Kaye SB. Comparison of the utility of Pascal dynamic contour tonometry with Goldmann applanation tonometry in routine clinical practice. J Glaucoma 2013; 22:422-426.
    • (2013) J Glaucoma , vol.22 , pp. 422-426
    • Anderson, M.F.1    Agius-Fernandez, A.2    Kaye, S.B.3
  • 38
    • 0008704458 scopus 로고
    • Automatic tonometer with exact theory: Various biological applications
    • Mackay RS, Marg E, Oechsli R. Automatic tonometer with exact theory: various biological applications. Science 1960; 131:1668-1669.
    • (1960) Science , vol.131 , pp. 1668-1669
    • Mackay, R.S.1    Marg, E.2    Oechsli, R.3
  • 39
    • 79952744549 scopus 로고    scopus 로고
    • Comparison of goldmann applanation tonometer, noncontact tonometer, and TonoPen XL for intraocular pressure measurement in different types of glaucomatous, ocular hypertensive, and normal eyes
    • Kim NR, Kim CY, Kim H, et al. Comparison of goldmann applanation tonometer, noncontact tonometer, and TonoPen XL for intraocular pressure measurement in different types of glaucomatous, ocular hypertensive, and normal eyes. Curr Eye Res 2011; 36:295-300.
    • (2011) Curr Eye Res , vol.36 , pp. 295-300
    • Kim, N.R.1    Kim, C.Y.2    Kim, H.3
  • 40
    • 0035091093 scopus 로고    scopus 로고
    • New tonopen XL: Comparison with the goldmann tonometer
    • Iester M, Mermoud A, Achache F, Roy S. New Tonopen XL: comparison with the Goldmann tonometer. Eye (Lond) 2001; 15:52-58.
    • (2001) Eye (Lond) , vol.15 , pp. 52-58
    • Iester, M.1    Mermoud, A.2    Achache, F.3    Roy, S.4
  • 41
    • 33746350421 scopus 로고    scopus 로고
    • Central and peripheral corneal thickness: Influence on the iop measurement by tonopen
    • Amaral WO, Teixeira RM, Alencar LM, et al. Central and peripheral corneal thickness: influence on the iop measurement by Tonopen. Arq Bras Oftalmol 2006; 69:41-45.
    • (2006) Arq Bras Oftalmol , vol.69 , pp. 41-45
    • Amaral, W.O.1    Teixeira, R.M.2    Alencar, L.M.3
  • 42
    • 78549269739 scopus 로고    scopus 로고
    • Transpalpebral measurement of intraocular pressure using the diaton tonometer versus standard goldmann applanation tonometry
    • Li Y, Shi J, Duan X, Fan F. Transpalpebral measurement of intraocular pressure using the Diaton tonometer versus standard Goldmann applanation tonometry. Graefes Arch Clin Exp Ophthalmol 2010; 248:1765-1770.
    • (2010) Graefes Arch Clin Exp Ophthalmol , vol.248 , pp. 1765-1770
    • Li, Y.1    Shi, J.2    Duan, X.3    Fan, F.4
  • 43
    • 43249105230 scopus 로고    scopus 로고
    • Central corneal thickness and diaton transpalpebral tonometry
    • Toker MI, Vural A, Erdogan H, et al. Central corneal thickness and Diaton transpalpebral tonometry. Graefes Arch Clin Exp Ophthalmol 2008; 246:881-889.
    • (2008) Graefes Arch Clin Exp Ophthalmol , vol.246 , pp. 881-889
    • Toker, M.I.1    Vural, A.2    Erdogan, H.3
  • 44
    • 84862558129 scopus 로고    scopus 로고
    • Diaton tonometry: An assessment of validity and preference against goldmann tonometry
    • Doherty MD, Carrim ZI, O'Neill DP. Diaton tonometry: an assessment of validity and preference against Goldmann tonometry. Clin Exp Ophthalmol 2012; 40:e171-e175.
    • (2012) Clin Exp Ophthalmol , vol.40 , pp. e171-e175
    • Doherty, M.D.1    Carrim, Z.I.2    O'Neill, D.P.3
  • 45
    • 84863317154 scopus 로고    scopus 로고
    • Comparative evaluation of diaton and goldmann applanation tonometers
    • Bali SJ, Bhartiya S, Sobti A, et al. Comparative evaluation of Diaton and Goldmann applanation tonometers. Ophthalmologica 2012; 228:42-46.
    • (2012) Ophthalmologica , vol.228 , pp. 42-46
    • Bali, S.J.1    Bhartiya, S.2    Sobti, A.3
  • 46
    • 0034115306 scopus 로고    scopus 로고
    • A new induction-based impact method for measuring intraocular pressure
    • Kontiola AI. A new induction-based impact method for measuring intraocular pressure. Acta Ophthalmol Scand 2000; 78:142-145.
    • (2000) Acta Ophthalmol Scand , vol.78 , pp. 142-145
    • Kontiola, A.I.1
  • 47
    • 0030318702 scopus 로고    scopus 로고
    • A new electromechanical method for measuring intraocular pressure
    • Kontiola A. A new electromechanical method for measuring intraocular pressure. Doc Ophthalmol 1996; 93:265-276.
    • (1996) Doc Ophthalmol , vol.93 , pp. 265-276
    • Kontiola, A.1
  • 48
    • 34247633160 scopus 로고    scopus 로고
    • Reproducibility and tolerability of the ICare rebound tonometerinschool children
    • Sahin A, Basmak H, Niyaz L, Yildirim N. Reproducibility and tolerability of the ICare rebound tonometerinschool children. JGlaucoma 2007; 16:185-188.
    • (2007) JGlaucoma , vol.16 , pp. 185-188
    • Sahin, A.1    Basmak, H.2    Niyaz, L.3    Yildirim, N.4
  • 49
    • 28244452880 scopus 로고    scopus 로고
    • Comparison of the ICare rebound tonometer with the goldmann tonometer in a normal population
    • Fernandes P, Diaz-Rey JA, Queiros A, et al. Comparison of the ICare rebound tonometer with the Goldmann tonometer in a normal population. Ophthalmic Physiol Opt 2005; 25:436-440.
    • (2005) Ophthalmic Physiol Opt , vol.25 , pp. 436-440
    • Fernandes, P.1    Diaz-Rey, J.A.2    Queiros, A.3
  • 50
    • 34447631350 scopus 로고    scopus 로고
    • Comparison of the rebound tonometer with the goldmann applanation tonometer in glaucoma patients
    • Sahin A, Niyaz L, Yildirim N. Comparison of the rebound tonometer with the Goldmann applanation tonometer in glaucoma patients. Clin Exp Ophthalmol 2007; 35:335-339.
    • (2007) Clin Exp Ophthalmol , vol.35 , pp. 335-339
    • Sahin, A.1    Niyaz, L.2    Yildirim, N.3
  • 51
    • 84877749079 scopus 로고    scopus 로고
    • Comparison of handheld rebound tonometry with goldmann applanation tonometry in children with glaucoma: A cohort study
    • Dahlmann-Noor AH, Puertas R, Tabasa-Lim S, et al. Comparison of handheld rebound tonometry with Goldmann applanation tonometry in children with glaucoma: a cohort study. BMJ Open 2013; 3:e001788.
    • (2013) BMJ Open , vol.3
    • Dahlmann-Noor, A.H.1    Puertas, R.2    Tabasa-Lim, S.3
  • 52
    • 78651425786 scopus 로고    scopus 로고
    • Comparison of ICare rebound tonometer with noncontact tonometer in healthy children
    • Kageyama M, Hirooka K, Baba T, Shiraga F. Comparison of ICare rebound tonometer with noncontact tonometer in healthy children. J Glaucoma 2011; 20:63-66.
    • (2011) J Glaucoma , vol.20 , pp. 63-66
    • Kageyama, M.1    Hirooka, K.2    Baba, T.3    Shiraga, F.4
  • 53
    • 79956189255 scopus 로고    scopus 로고
    • Icare rebound tonometry in children with known and suspected glaucoma
    • Flemmons MS, Hsiao YC, Dzau J, et al. Icare rebound tonometry in children with known and suspected glaucoma. J AAPOS 2011; 15:153-157.
    • (2011) J AAPOS , vol.15 , pp. 153-157
    • Flemmons, M.S.1    Hsiao, Y.C.2    Dzau, J.3
  • 54
    • 84875734672 scopus 로고    scopus 로고
    • Rebound tonometry in children: A report by the American academy of ophthalmology
    • Lambert SR, Melia M, Buffenn AN, et al. Rebound tonometry in children: a report by the American Academy of Ophthalmology. Ophthalmology 2013; 120:e21-e27.
    • (2013) Ophthalmology , vol.120 , pp. e21-e27
    • Lambert, S.R.1    Melia, M.2    Buffenn, A.N.3
  • 55
    • 84899435700 scopus 로고    scopus 로고
    • Assessment of IcareONE rebound tonometer for self-measuring intraocular pressure
    • Sakamoto M, Kanamori A, Fujihara M, et al. Assessment of IcareONE rebound tonometer for self-measuring intraocular pressure. Acta Ophthalmol 2014; 92:243-248.
    • (2014) Acta Ophthalmol , vol.92 , pp. 243-248
    • Sakamoto, M.1    Kanamori, A.2    Fujihara, M.3
  • 56
    • 84942190768 scopus 로고    scopus 로고
    • Clinical evaluation of the new rebound tonometers icare PRO and icare ONE compared with the goldmann tonometer
    • [Epub on Journal website, no further details of publication]
    • Moreno-Montanes J, Martinez-de-la-Casa JM, Sabater AL, et al. Clinical Evaluation of the New Rebound Tonometers Icare PRO and Icare ONE Compared With the Goldmann Tonometer. J Glaucoma 2014. [Epub on Journal website, no further details of publication]
    • (2014) J Glaucoma
    • Moreno-Montanes, J.1    Martinez-De-La-Casa, J.M.2    Sabater, A.L.3
  • 57
    • 84864151636 scopus 로고    scopus 로고
    • Icare ONE rebound versus goldmann applanation tonometry in children with known or suspected glaucoma
    • e1
    • Gandhi NG, Prakalapakorn SG, El-Dairi MA, et al. Icare ONE rebound versus Goldmann applanation tonometry in children with known or suspected glaucoma. Am J Ophthalmol 2012; 154:843-849; e1.
    • (2012) Am J Ophthalmol , vol.154 , pp. 843-849
    • Gandhi, N.G.1    Prakalapakorn, S.G.2    El-Dairi, M.A.3
  • 58
    • 66249135995 scopus 로고    scopus 로고
    • Wireless contact lens sensor for intraocular pressure monitoring: Assessment on enucleated pig eyes
    • Leonardi M, Pitchon EM, Bertsch A, et al. Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes. Acta Ophthalmol 2009; 87:433-437.
    • (2009) Acta Ophthalmol , vol.87 , pp. 433-437
    • Leonardi, M.1    Pitchon, E.M.2    Bertsch, A.3
  • 59
    • 79955031844 scopus 로고    scopus 로고
    • Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: Initial clinical experience in patients with open angle glaucoma
    • Mansouri K, Shaarawy T. Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma. Br J Ophthalmol 2011; 95:627-629.
    • (2011) Br J Ophthalmol , vol.95 , pp. 627-629
    • Mansouri, K.1    Shaarawy, T.2
  • 60
    • 84871203646 scopus 로고    scopus 로고
    • Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: Safety, tolerability, and reproducibility in patients with glaucoma
    • Mansouri K, Medeiros FA, Tafreshi A, Weinreb RN. Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma. Arch Ophthalmol 2012; 130:1534-1539.
    • (2012) Arch Ophthalmol , vol.130 , pp. 1534-1539
    • Mansouri, K.1    Medeiros, F.A.2    Tafreshi, A.3    Weinreb, R.N.4
  • 61
    • 84891868131 scopus 로고    scopus 로고
    • Evaluation of continuous 24-h intraocular pressure monitoring for assessment of prostaglandin-induced pressure reduction in glaucoma
    • Hollo G, Kothy P, Vargha P. Evaluation of continuous 24-h intraocular pressure monitoring for assessment of prostaglandin-induced pressure reduction in glaucoma. J Glaucoma 2014; 23:e6-e12.
    • (2014) J Glaucoma , vol.23 , pp. e6-e12
    • Hollo, G.1    Kothy, P.2    Vargha, P.3
  • 62
    • 84908112476 scopus 로고    scopus 로고
    • An implantable intraocular pressure transducer: Initial safety outcomes
    • Melki S, Todani A, Cherfan G. An implantable intraocular pressure transducer: initial safety outcomes. J Am Med Assoc Ophthalmol 2014; 132:1221-1225.
    • (2014) J Am Med Assoc Ophthalmol , vol.132 , pp. 1221-1225
    • Melki, S.1    Todani, A.2    Cherfan, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.