The Myth of Clinical Precision

(1)  Brandt, James D a  

a NONE

Author keywords

[No Author keywords available]

Indexed keywords

DIAGNOSTIC ERROR; EDITORIAL; GLAUCOMA; GLYCEMIC CONTROL; HUMAN; LENS IMPLANT; MEDICAL DECISION MAKING; MEDICAL EXPERT; OCULOPLETHYSMOGRAPHY; PATIENT CARE; PRIORITY JOURNAL; REFRACTION ERROR;

EID: 57949086585     PISSN: 01616420     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ophtha.2008.10.027     Document Type: Editorial
Times cited : (7)

References (6)
  • 1
    • 70449195078 scopus 로고
    • Über applanationstonometrie
    • Goldmann H., and Schmidt T. Über applanationstonometrie. Ophthalmologica 134 (1957) 221-242
    • (1957) Ophthalmologica , vol.134 , pp. 221-242
    • Goldmann, H.1    Schmidt, T.2
  • 2
    • 0025614886 scopus 로고
    • Tonometer utilization, accuracy, and calibration under field conditions
    • Wessels I.F., and Oh Y. Tonometer utilization, accuracy, and calibration under field conditions. Arch Ophthalmol 108 (1990) 1709-1712
    • (1990) Arch Ophthalmol , vol.108 , pp. 1709-1712
    • Wessels, I.F.1    Oh, Y.2
  • 3
    • 18744372146 scopus 로고    scopus 로고
    • Frequency of goldmann applanation tonometer calibration error checks
    • Sandhu S.S., Chattopadhyay S., Birch M.K., and Ray-Chaudhuri N. Frequency of goldmann applanation tonometer calibration error checks. J Glaucoma 14 (2005) 215-218
    • (2005) J Glaucoma , vol.14 , pp. 215-218
    • Sandhu, S.S.1    Chattopadhyay, S.2    Birch, M.K.3    Ray-Chaudhuri, N.4
  • 4
    • 34250331223 scopus 로고    scopus 로고
    • Goldmann applanation tonometer calibration error checks: current practice in the UK
    • Kumar N., and Jivan S. Goldmann applanation tonometer calibration error checks: current practice in the UK. Eye 21 (2007) 733-734
    • (2007) Eye , vol.21 , pp. 733-734
    • Kumar, N.1    Jivan, S.2
  • 5
    • 57949111404 scopus 로고    scopus 로고
    • Measurement of Goldmann applanation tonometer calibration error
    • Choudhari N.S., George R., Baskaran M., et al. Measurement of Goldmann applanation tonometer calibration error. Ophthalmology 116 (2009) 3-8
    • (2009) Ophthalmology , vol.116 , pp. 3-8
    • Choudhari, N.S.1    George, R.2    Baskaran, M.3
  • 6
    • 57949104086 scopus 로고    scopus 로고
    • The accuracy of continued clinical use of Goldmann applanation tonometers with known calibration errors
    • Sandhu S.S., Chattopadhyay S., Amariotakis G.A., et al. The accuracy of continued clinical use of Goldmann applanation tonometers with known calibration errors. Ophthalmology 116 (2009) 9-13
    • (2009) Ophthalmology , vol.116 , pp. 9-13
    • Sandhu, S.S.1    Chattopadhyay, S.2    Amariotakis, G.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.