메뉴 건너뛰기




Volumn 21, Issue 1, 2012, Pages 35-40

IOP measured by dynamic contour tonometry correlates with IOP measured by goldmann applanation tonometry and non-contact tonometry in Japanese individuals

Author keywords

dynamic contour tonometry; Goldmann applanation tonometry; noncontact tonometry; ocular pulse amplitude; pulse pressure

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CORNEA CURVATURE; CORNEA THICKNESS; DYNAMIC CONTOUR TONOMETRY; EYE AXIS LENGTH; FEMALE; GOLDMANN APPLANATION TONOMETRY; HUMAN; INTERMETHOD COMPARISON; INTRAOCULAR PRESSURE; JAPANESE; MAJOR CLINICAL STUDY; MALE; NON CONTACT TONOMETRY; OCULOPLETHYSMOGRAPHY; PRESSURE MEASUREMENT; PRIORITY JOURNAL; PULSE PRESSURE; TONOMETER;

EID: 84855457936     PISSN: 10570829     EISSN: 1536481X     Source Type: Journal    
DOI: 10.1097/IJG.0b013e31820275b4     Document Type: Article
Times cited : (30)

References (29)
  • 1
    • 0020955893 scopus 로고
    • The epidemiology of open-angle glaucoma: A review
    • Leske MC. The epidemiology of open angle glaucoma: a review. Am J Epidemiol. 1983;118:166-191. (Pubitemid 13029361)
    • (1983) American Journal of Epidemiology , vol.118 , Issue.2 , pp. 166-191
    • Leske, M.C.1
  • 2
    • 0027291601 scopus 로고
    • Sources of error with use of Goldmann-type tonometers
    • DOI 10.1016/0039-6257(93)90053-A
    • Whitacre MM, Stein R. Sources of error with use of Goldmann type tonometers. Surv Ophthalmol. 1993;38:1-30. (Pubitemid 23234285)
    • (1993) Survey of Ophthalmology , vol.38 , Issue.1 , pp. 1-30
    • Whitacre, M.M.1    Stein, R.2
  • 3
    • 4444321895 scopus 로고    scopus 로고
    • Dynamic contour tonometry: A comparative study on human cadaver eyes
    • DOI 10.1001/archopht.122.9.1287
    • Kniestedt C, Nee M, Stamper RL. Dynamic contour tonometry: a comparative study on human cadaver eyes. Arch Ophthalmol. 2004;122:1287-1293. (Pubitemid 39180848)
    • (2004) Archives of Ophthalmology , vol.122 , Issue.9 , pp. 1287-1293
    • Kniestedt, C.1    Nee, M.2    Stamper, R.L.3
  • 4
    • 25644460363 scopus 로고    scopus 로고
    • Dynamic contour tonometry: Presentation of a new tonometer
    • DOI 10.1097/01.ijg.0000176936.16015.4e
    • Kanngiesser HE, Kniestedt C, Robert YC. Dynamic contour tonometry: presentation of a new tonometer. J Glaucoma. 2005;14:344-350. (Pubitemid 41383326)
    • (2005) Journal of Glaucoma , vol.14 , Issue.5 , pp. 344-350
    • Kanngiesser, H.E.1    Kniestedt, C.2    Robert, Y.C.A.3
  • 5
    • 0017888407 scopus 로고
    • A clinical procedure for the measurements of the ocular pulse-pressure relationship and the ophthalmic arterial pressure
    • Langham ME, To'Mey KF. A clinical procedure for the measurements of ocular pulse-pressure relationship and the ophthalmic arterial pressure. Exp Eye Res. 1978;27:17-25. (Pubitemid 8360083)
    • (1978) Experimental Eye Research , vol.27 , Issue.1 , pp. 17-25
    • Langham, M.E.1    To'mey, K.F.2
  • 6
    • 33747203182 scopus 로고    scopus 로고
    • Ocular pulse amplitude in healthy subjects as measured by dynamic contour tonometry
    • DOI 10.1001/archopht.124.8.1104
    • Kaufmann C, Bachmann LM, Robert YC, et al. Ocular pulse amplitude in healthy subjects as measured by dynamic contour tonometry. Arch Ophthalmol. 2006;124:1104-1108. (Pubitemid 44232339)
    • (2006) Archives of Ophthalmology , vol.124 , Issue.8 , pp. 1104-1108
    • Kaufmann, C.1    Bachmann, L.M.2    Robert, Y.C.3    Thiel, M.A.4
  • 7
    • 58149140508 scopus 로고    scopus 로고
    • Ocular pulse amplitude in normal tension and primary open angle glaucoma
    • Stalmans I, Harris A, Vanbellinghen V, et al. Ocular pulse amplitude in normal tension and primary open angle glaucoma. J Glaucoma. 2008;17:403-407.
    • (2008) J Glaucoma , vol.17 , pp. 403-407
    • Stalmans, I.1    Harris, A.2    Vanbellinghen, V.3
  • 8
    • 0031794457 scopus 로고    scopus 로고
    • Positive correlation between tono-pen intraocular pressure and central corneal thickness
    • DOI 10.1016/S0161-6420(98)91029-6
    • Dohadwala AA, Munger R, Damji KF. Positive correlation between Tono-pen intraocular pressure and central corneal thickness. Ophthalmology. 1998;105:1849-1854. (Pubitemid 28509724)
    • (1998) Ophthalmology , vol.105 , Issue.10 , pp. 1849-1854
    • Dohadwala, A.A.1    Munger, R.2    Damji, K.F.3
  • 9
    • 0025838179 scopus 로고
    • Epidemiology of glaucoma in Japan: A nationwide glaucoma survey
    • Shiose Y, Kitazawa Y, Tsukahara S, et al. Epidemiology of glaucoma in Japan: a nationwide glaucoma survey. Jpn J Ophthalmol. 1991;35:133-155.
    • (1991) Jpn J Ophthalmol , vol.35 , pp. 133-155
    • Shiose, Y.1    Kitazawa, Y.2    Tsukahara, S.3
  • 10
    • 0033708908 scopus 로고    scopus 로고
    • Central corneal thickness of normal tension glaucoma patients in Japan
    • Wu LL, Suzuki Y, Ideta R, et al. Central corneal thickness of normal tension glaucoma patients in Japan. Jpn J Ophthalmol. 2000;44:643-647.
    • (2000) Jpn J Ophthalmol , vol.44 , pp. 643-647
    • Wu, L.L.1    Suzuki, Y.2    Ideta, R.3
  • 12
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 30344436327 scopus 로고    scopus 로고
    • Intraocular pressure measurement - Comparison of dynamic contour tonometry and Goldmann applanation tonometry
    • DOI 10.1097/01.ijg.0000196655.85460.d6, PII 0006119820060200000002
    • Schneider E, Grehn F. Intraocular pressure measurement-comparison of dynamic contour tonometry and goldmann applanation tonometry. J Glaucoma. 2006;15:2-6. (Pubitemid 43068411)
    • (2006) Journal of Glaucoma , vol.15 , Issue.1 , pp. 2-6
    • Schneider, E.1    Grehn, F.2
  • 14
    • 4344659799 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry with Goldmann applanation tonometry
    • DOI 10.1167/iovs.04-0018
    • Kaufmann C, Bachmann LM, Thiel MA. Comparison of dynamic contour tonometry with Goldmann applanation tonometry. Invest Ophthalmol Vis Sci. 2004;45:3118-3121. (Pubitemid 39121844)
    • (2004) Investigative Ophthalmology and Visual Science , vol.45 , Issue.9 , pp. 3118-3121
    • Kaufmann, C.1    Bachmann, L.M.2    Thiel, M.A.3
  • 16
    • 67651091459 scopus 로고    scopus 로고
    • Correlation of intraocular pressure measured with Goldmann and dynamic contour tonometry in normal and glaucomatous eyes
    • Realini T, Weinreb RN, Hobbs G, et al. Correlation of intraocular pressure measured with Goldmann and dynamic contour tonometry in normal and glaucomatous eyes. J Glaucoma. 2009;18:119-123.
    • (2009) J Glaucoma , vol.18 , pp. 119-123
    • Realini, T.1    Weinreb, R.N.2    Hobbs, G.3
  • 17
    • 23044486766 scopus 로고    scopus 로고
    • Corneal thickness in an ophthalmologically normal Japanese population
    • DOI 10.1016/j.ophtha.2005.03.022, PII S0161642005004835
    • Suzuki S, Suzuki Y, Iwase A, et al. Corneal thickness in an ophthalmologically normal Japanese population. Ophthalmol-ogy. 2005;112:1327-1336. (Pubitemid 41074619)
    • (2005) Ophthalmology , vol.112 , Issue.8 , pp. 1327-1336
    • Suzuki, S.1    Suzuki, Y.2    Iwase, A.3    Araie, M.4
  • 18
    • 27744519845 scopus 로고    scopus 로고
    • Clinical comparison of contour and applanation tonometry and their relationship to pachymetry
    • DOI 10.1001/archopht.123.11.1532
    • Kniestedt C, Lin S, Choe J, et al. Clinical comparison of contour and applanation tonometry and their relationship to pachymetry. Arch Ophthalmol. 2005;123:1532-1537. (Pubitemid 41626689)
    • (2005) Archives of Ophthalmology , vol.123 , Issue.11 , pp. 1532-1537
    • Kniestedt, C.1    Lin, S.2    Choe, J.3    Bostrom, A.4    Nee, M.5    Stamper, R.L.6
  • 19
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • DOI 10.1016/S0039-6257(00)00110-7, PII S0039625700001107
    • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000;44: 367-408. (Pubitemid 30151145)
    • (2000) Survey of Ophthalmology , vol.44 , Issue.5 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 20
    • 67650660340 scopus 로고    scopus 로고
    • Influence ofage, central corneal thickness, and quality score on dynamic contour tonometry
    • Jordao ML, Lupinacci AP, Ferreira EL, et al. Influence ofage, central corneal thickness, and quality score on dynamic contour tonometry. Eye. 2009;23:1364-1369.
    • (2009) Eye , vol.23 , pp. 1364-1369
    • Jordao, M.L.1    Lupinacci, A.P.2    Ferreira, E.L.3
  • 21
    • 33845807890 scopus 로고    scopus 로고
    • Effects of corneal thickness, corneal curvature, and intraocular pressure level on goldmann applanation tonometry and dynamic contour tonometry
    • DOI 10.1016/j.ophtha.2006.06.047, PII S0161642006010086
    • Francis BA, Hsieh A, Lai MY, et al. Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonometry. Ophthalmology. 2007;114:20-26. (Pubitemid 46014299)
    • (2007) Ophthalmology , vol.114 , Issue.1 , pp. 20-26
    • Francis, B.A.1    Hsieh, A.2    Lai, M.-Y.3    Chopra, V.4    Pena, F.5    Azen, S.6    Varma, R.7
  • 22
    • 13844318981 scopus 로고    scopus 로고
    • Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK
    • DOI 10.1016/j.jcrs.2003.12.033, PII S0886335004000100
    • Siganos DS, Papastergiou GI, Moedas C. Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK. J Cataract Refract Surg. 2004;30:746-751. (Pubitemid 38501466)
    • (2004) Journal of Cataract and Refractive Surgery , vol.30 , Issue.4 , pp. 746-751
    • Siganos, D.S.1    Papastergiou, G.I.2    Moedas, C.3
  • 23
    • 0034441936 scopus 로고    scopus 로고
    • Influence of keratometric readings on comparative intraocular pressure measurements with Goldmann, Tono-Pen, and noncontact tonometers
    • Paranhos A Jr, Paranhos FR, Prata JA Jr, et al. Influence of keratometric readings on comparative intraocular pressure measurements with Goldmann, Tono-Pen, and non-contact tonometers. J Glaucoma. 2000;9:219-223. (Pubitemid 32429362)
    • (2000) Journal of Glaucoma , vol.9 , Issue.3 , pp. 219-223
    • Paranhos Jr., A.1    Paranhos, F.R.L.2    Prata Jr., J.A.3    Omi, C.A.4    Mello, P.A.A.5    Bruce Shields, M.6
  • 26
    • 2942596237 scopus 로고    scopus 로고
    • Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry
    • Hoffmann EM, Grus FH, Pfeiffer N. Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry. BMC Ophthalmol. 2004;4:4.
    • (2004) BMC Ophthalmol , vol.4 , pp. 4
    • Hoffmann, E.M.1    Grus, F.H.2    Pfeiffer, N.3
  • 27
    • 65349090774 scopus 로고    scopus 로고
    • Relationship between ocular pulse amplitude and systemic blood pressure measurements
    • Grieshaber MC, Katamay R, Gugleta K, et al. Relationship between ocular pulse amplitude and systemic blood pressure measurements. Acta Ophthalmol. 2009;87:329-334.
    • (2009) Acta Ophthalmol , vol.87 , pp. 329-334
    • Grieshaber, M.C.1    Katamay, R.2    Gugleta, K.3
  • 29
    • 34147119213 scopus 로고    scopus 로고
    • Clinical evaluation of the Pascal dynamic contour tonometer
    • Detry-Morel M, Jamart J, Detry MB, et al. Clinical evaluation of the Pascal dynamic contour tonometer. J Fr Ophtalmol. 2007;30:260-270.
    • (2007) J Fr Ophtalmol , vol.30 , pp. 260-270
    • Detry-Morel, M.1    Jamart, J.2    Detry, M.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.