Volumn 18, Issue 9, 2009, Pages 666-673

Repeatability and reproducibility for intraocular pressure measurement by dynamic contour, ocular response analyzer, and goldmann applanation tonometry

Author keywords

Goldmann applanation tonometry; Intraocular pressure; Ocular response analyzer tonometry; Pascal dynamic contour tonometry; Repeatability; Reproducibility

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL EVALUATION; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; EYE; EYE EXAMINATION; FEMALE; GLAUCOMA; GOLDMANN APPLANATION TONOMETRY; HUMAN; INTERMETHOD COMPARISON; INTRAOCULAR HYPERTENSION; INTRAOCULAR PRESSURE; MAJOR CLINICAL STUDY; MALE; OCULOPLETHYSMOGRAPHY; OPEN ANGLE GLAUCOMA; OUTPATIENT DEPARTMENT; PASCAL DYNAMIC CONTOUR TONOMETRY; PRIORITY JOURNAL; PROSPECTIVE STUDY;

EID: 74549215576     PISSN: 10570829     EISSN: None     Source Type: Journal    
DOI: 10.1097/IJG.0b013e31819c487d     Document Type: Article
Times cited : (41)

References (37)
  • 1
    • 25644460363 scopus 로고    scopus 로고
    • Dynamic contour tonometry: Presentation of a new tonometer
    • Kanngiesser HE, Kniestedt C, Robert YC. Dynamic contour tonometry: presentation of a new tonometer. J Glaucoma. 2005;14:344-350
    • (2005) J Glaucoma , vol.14 , pp. 344-350
    • Kanngiesser, H.E.1    Kniestedt, C.2    Robert, Y.C.3
  • 3
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    • Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005;31:156-162
    • (2005) J Cataract Refract Surg , vol.31 , pp. 156-162
    • Luce, D.A.1
  • 4
    • 34248347895 scopus 로고    scopus 로고
    • Corneal thickness and age-related biomechanical properties of the cornea measured with the ocular response analyzer
    • Kotecha A, Elsheikh A, Roberts CR, et al. Corneal thickness and age-related biomechanical properties of the cornea measured with the ocular response analyzer. Invest Ophthalmol Vis Sci. 2006;47:5337-5347
    • (2006) Invest Ophthalmol Vis Sci , vol.47 , pp. 5337-5347
    • Kotecha, A.1    Elsheikh, A.2    Roberts, C.R.3
  • 5
    • 13844313434 scopus 로고    scopus 로고
    • Influence of corneal biomechanical properties on intraocular pressure measurement: Quantitative analysis
    • Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg. 2005;31:146-155
    • (2005) J Cataract Refract Surg , vol.31 , pp. 146-155
    • Liu, J.1    Roberts, C.J.2
  • 6
    • 33845499055 scopus 로고    scopus 로고
    • Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry
    • Pepose JS, Feigenbaum SK, Qazi MA, et al. Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry. Am J Ophthalmol. 2007;143:39-47
    • (2007) Am J Ophthalmol , vol.143 , pp. 39-47
    • Pepose, J.S.1    Feigenbaum, S.K.2    Qazi, M.A.3
  • 7
    • 33845807890 scopus 로고    scopus 로고
    • Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry, and dynamic contour tonometry
    • for Los Angeles Latino Eye Study Group.
    • Francis BA, Hsieh A, Lai M, et al, for Los Angeles Latino Eye Study Group. Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry, and dynamic contour tonometry. Ophthalmology. 2007;114:20-26
    • (2007) Ophthalmology , vol.114 , pp. 20-26
    • Francis, B.A.1    Hsieh, A.2    Lai, M.3
  • 8
    • 7544224832 scopus 로고    scopus 로고
    • Central corneal thickness and measured IOP response to topical ocular hypertensive medication in the ocular hypertension treatment study
    • Ocular Hypertension Treatment Study (OHTS) Group.
    • Brandt JD, Beiser JA, Gordon MO, et al, Ocular Hypertension Treatment Study (OHTS) Group. Central corneal thickness and measured IOP response to topical ocular hypertensive medication in the ocular hypertension treatment study. Am J Ophthalmol. 2004;138:717-722
    • (2004) Am J Ophthalmol , vol.138 , pp. 717-722
    • Brandt, J.D.1    Beiser, J.A.2    Gordon, M.O.3
  • 9
    • 20444489648 scopus 로고    scopus 로고
    • Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration states
    • Kniestedt C, Nee M, Stamper RL. Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration states. Graefes Arch Clin Exp Ophthalmol. 2005;243:359-366
    • (2005) Graefes Arch Clin Exp Ophthalmol , vol.243 , pp. 359-366
    • Kniestedt, C.1    Nee, M.2    Stamper, R.L.3
  • 10
    • 27744519845 scopus 로고    scopus 로고
    • Clinical comparison of contour and applanation tonometry and their relationship to pachymetry
    • Kniestedt C, Lin S, Choe J, et al. Clinical comparison of contour and applanation tonometry and their relationship to pachymetry. Arch Ophthalmol. 2005;123:1532-1537
    • (2005) Arch Ophthalmol , vol.123 , pp. 1532-1537
    • Kniestedt, C.1    Lin, S.2    Choe, J.3
  • 11
    • 22544486553 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry with Goldmann applanation tonometry over a wide range of central corneal thickness
    • Doyle A, Lachkar Y. Comparison of dynamic contour tonometry with Goldmann applanation tonometry over a wide range of central corneal thickness. J Glaucoma. 2005;14: 288-292
    • (2005) J Glaucoma , vol.14 , pp. 288-292
    • Doyle, A.1    Lachkar, Y.2
  • 12
    • 37349045954 scopus 로고    scopus 로고
    • Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of intraocular pressure
    • Broman AT, Congdon NG, Bandeen-Roche K, et al. Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of intraocular pressure. J Glaucoma. 2007;16:581-588
    • (2007) J Glaucoma , vol.16 , pp. 581-588
    • Broman, A.T.1    Congdon, N.G.2    Bandeen-Roche, K.3
  • 13
    • 34548695879 scopus 로고    scopus 로고
    • Comparison of IOP measurements between ORA and GAT in normal Chinese
    • Lam A, Chen D, Chiu R, et al. Comparison of IOP measurements between ORA and GAT in normal Chinese. Optom Vis Sci. 2007;84:909-914
    • (2007) Optom Vis Sci , vol.84 , pp. 909-914
    • Lam, A.1    Chen, D.2    Chiu, R.3
  • 14
    • 33748924156 scopus 로고    scopus 로고
    • Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer
    • Medeiros FA, Weinreb RN. Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer. J Glaucoma. 2006;15:364-370
    • (2006) J Glaucoma , vol.15 , pp. 364-370
    • Medeiros, F.A.1    Weinreb, R.N.2
  • 15
    • 23744463890 scopus 로고    scopus 로고
    • Dynamic contour tonometry for intraocular pressure measurement
    • Kamppeter BA, Jonas JB. Dynamic contour tonometry for intraocular pressure measurement. Am J Ophthalmol. 2005; 140:318-320
    • (2005) Am J Ophthalmol , vol.140 , pp. 318-320
    • Kamppeter, B.A.1    Jonas, J.B.2
  • 16
    • 30344436327 scopus 로고    scopus 로고
    • Intraocular pressure measurementcomparison of dynamic contour tonometry and Goldmann applanation tonometry
    • Schneider E, Grehn F. Intraocular pressure measurementcomparison of dynamic contour tonometry and Goldmann applanation tonometry. J Glaucoma. 2006;15:2-6
    • (2006) J Glaucoma , vol.15 , pp. 2-6
    • Schneider, E.1    Grehn, F.2
  • 17
    • 47249138174 scopus 로고    scopus 로고
    • Dynamic contour tonometry in comparison to intracameral IOP measurements
    • Boehm AG, Weber A, Spoerl E, et al. Dynamic contour tonometry in comparison to intracameral IOP measurements. Invest Ophthalmol Vis Sci. 2008;49:2472-2477
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 2472-2477
    • Boehm, A.G.1    Weber, A.2    Spoerl, E.3
  • 18
    • 48549094493 scopus 로고    scopus 로고
    • Ocular response analyzers in subjects with and without glaucoma
    • Sullivan-Mee M, Billingsley SC, Patel AD, et al. Ocular response analyzers in subjects with and without glaucoma. Optom Vis Sci. 2008;85:463-470
    • (2008) Optom Vis Sci , vol.85 , pp. 463-470
    • Sullivan-Mee, M.1    Billingsley, S.C.2    Patel, A.D.3
  • 19
    • 33845227093 scopus 로고    scopus 로고
    • Corneal hysteresis and intraocular pressure measurement in children using the Reichert ocular response analyzer
    • Kirwan C, O'Keefe M, Lanigan B. Corneal hysteresis and intraocular pressure measurement in children using the Reichert ocular response analyzer. Am J Ophthalmol. 2006;142: 990-992
    • (2006) Am J Ophthalmol , vol.142 , pp. 990-992
    • Kirwan, C.1    O'Keefe, M.2    Lanigan, B.3
  • 20
    • 33646761304 scopus 로고    scopus 로고
    • Correlation between intraocular pressure, central corneal thickness, stage of glaucoma, and demographic patient data
    • Kniestedt C, Lin S, Choe J, et al. Correlation between intraocular pressure, central corneal thickness, stage of glaucoma, and demographic patient data. J Glaucoma. 2006; 15:91-97
    • (2006) J Glaucoma , vol.15 , pp. 91-97
    • Kniestedt, C.1    Lin, S.2    Choe, J.3
  • 21
    • 49049107379 scopus 로고    scopus 로고
    • Corneal hysteresis but not corneal thickness correlates with optic nerve surface compliance in glaucoma patients
    • Wells AP, Garway-Heath DF, Poostchi A, et al. Corneal hysteresis but not corneal thickness correlates with optic nerve surface compliance in glaucoma patients. Invest Ophthalmol Vis Sci. 2008;49:3262-3268
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 3262-3268
    • Wells, A.P.1    Garway-Heath, D.F.2    Poostchi, A.3
  • 22
    • 37349013501 scopus 로고    scopus 로고
    • Clinical comparison of Pascals dynamic contour tonometry and Goldmann applanation tonometry in asymmetric open-angle glaucoma
    • Sullivan-Mee M, Halverson KD, Qualls C. Clinical comparison of Pascals dynamic contour tonometry and Goldmann applanation tonometry in asymmetric open-angle glaucoma. J Glaucoma. 2007;16:694-699
    • (2007) J Glaucoma , vol.16 , pp. 694-699
    • Sullivan-Mee, M.1    Halverson, K.D.2    Qualls, C.3
  • 23
    • 33646190149 scopus 로고    scopus 로고
    • Central corneal thickness and corneal hysteresis associated with glaucoma damage
    • Congdon NG, Broman AT, Bandeen-Roche K, et al. Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol. 2006;141:868-875
    • (2006) Am J Ophthalmol , vol.141 , pp. 868-875
    • Congdon, N.G.1    Broman, A.T.2    Bandeen-Roche, K.3
  • 24
    • 42049095265 scopus 로고    scopus 로고
    • Lower corneal hysteresis in glaucoma patients with acquired pit of the optic nerve (APON)
    • Bochmann F, Ang GS, Azuara-Blanco A. Lower corneal hysteresis in glaucoma patients with acquired pit of the optic nerve (APON). Graefes Arch Clin Exp Ophthalmol. 2008;246: 735-738
    • (2008) Graefes Arch Clin Exp Ophthalmol , vol.246 , pp. 735-738
    • Bochmann, F.1    Ang, G.S.2    Azuara-Blanco, A.3
  • 25
    • 41949128428 scopus 로고    scopus 로고
    • Reproducibility and clinical relevance of the ocular response analyzer in nonoperated eyes: Corneal biomechanical and tonometric implications
    • Moreno-Montanes J, Maldonado MJ, Garcia N, et al. Reproducibility and clinical relevance of the ocular response analyzer in nonoperated eyes: corneal biomechanical and tonometric implications. Invest Ophthalmol Vis Sci. 2008;49: 968-974
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 968-974
    • Moreno-Montanes, J.1    Maldonado, M.J.2    Garcia, N.3
  • 26
    • 28444475214 scopus 로고    scopus 로고
    • The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry
    • Kotecha A, White ET, Shewry JM, et al. The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry. Br J Ophthalmol. 2005; 89:1572-1575
    • (2005) Br J Ophthalmol , vol.89 , pp. 1572-1575
    • Kotecha, A.1    White, E.T.2    Shewry, J.M.3
  • 27
    • 41149083154 scopus 로고    scopus 로고
    • Is the Pascal-Tonometer suitable for measuring intraocular pressure in clinical routine? Long and short-term reproducibility of dynamic contour tonometry
    • Herdener S, Hafizovic D, Pache M, et al. Is the Pascal- Tonometer suitable for measuring intraocular pressure in clinical routine? Long and short-term reproducibility of dynamic contour tonometry. Eur J Ophthalmol. 2008;18:39-43
    • (2008) Eur J Ophthalmol , vol.18 , pp. 39-43
    • Herdener, S.1    Hafizovic, D.2    Pache, M.3
  • 28
    • 4344659799 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry with Goldmann applanation tonometry
    • Kaufmann C, Bachmann LM, Thiel MA. Comparison of dynamic contour tonometry with Goldmann applanation tonometry. Invest Ophthalmol Vis Sci. 2004;45:3118-3121
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , pp. 3118-3121
    • Kaufmann, C.1    Bachmann, L.M.2    Thiel, M.A.3
  • 29
    • 21344456718 scopus 로고    scopus 로고
    • A comparison of four methods of tonometry: Method agreement and interobserver variability
    • Tonnu PA, Ho T, Sharma K, et al. A comparison of four methods of tonometry: method agreement and interobserver variability. Br J Ophthalmol. 2005;89:847-850
    • (2005) Br J Ophthalmol , vol.89 , pp. 847-850
    • Tonnu, P.A.1    Ho, T.2    Sharma, K.3
  • 31
    • 0030596840 scopus 로고    scopus 로고
    • Measurement error
    • Bland JM, Altman DG.Measurement error. BMJ. 1996;313:744
    • (1996) BMJ , vol.313 , pp. 744
    • Bland, J.M.1    Altman, D.G.2
  • 32
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 33
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989;45:255-268
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.1
  • 34
    • 84975207356 scopus 로고    scopus 로고
    • A note on the concordance correlation coefficient
    • Lin LI. A note on the concordance correlation coefficient. Biometrics. 2000;56:324-325
    • (2000) Biometrics , vol.56 , pp. 324-325
    • Lin, L.I.1
  • 35
    • 74549172577 scopus 로고    scopus 로고
    • A SAS macro to compute Lin's concordance correlation with confidence intervals
    • Accessed on 4/9/2008
    • Cheng NF, Gansky SA. A SAS macro to compute Lin's concordance correlation with confidence intervals. UCSF CAN-DO website. Accessed on 4/9/2008. [http://www.ucsf. edu/cando/resources/software/linscon.sas]
    • UCSF CAN-DO Website
    • Cheng, N.F.1    Gansky, S.A.2
  • 36
    • 0028273231 scopus 로고
    • Reliability of intraocular pressure measurement with the Goldmann applanation tonometer in epidemiologic studies
    • Dielemans I, Vingerling JR, Hofman A, et al. Reliability of intraocular pressure measurement with the Goldmann applanation tonometer in epidemiologic studies. Graefes Arch Clin Exp Ophthalmol. 1994;232:141-144
    • (1994) Graefes Arch Clin Exp Ophthalmol , vol.232 , pp. 141-144
    • Dielemans, I.1    Vingerling, J.R.2    Hofman, A.3
  • 37
    • 0018903467 scopus 로고
    • The non-contact tonometer: Its value and limitations
    • Shields MB. The non-contact tonometer: its value and limitations. Surv Ophthalmol. 1980;24:211-219
    • (1980) Surv Ophthalmol , vol.24 , pp. 211-219
    • Shields, M.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.