-
1
-
-
77957299548
-
A novel device for rapid cleaning of poorly prepared colons
-
Moshkowitz M, Hirsch Y, Carmel I, et al. A novel device for rapid cleaning of poorly prepared colons. Endoscopy 2010;42(10):834-6
-
(2010)
Endoscopy
, vol.42
, Issue.10
, pp. 834-836
-
-
Moshkowitz, M.1
Hirsch, Y.2
Carmel, I.3
-
2
-
-
84864404452
-
MedJet - A new CO2-based disposable cleaning device allows safe and effective bowel cleansing during colonoscopy: A pilot study
-
Kiesslich R, Schuster N, Hoffman A, et al. MedJet - a new CO2-based disposable cleaning device allows safe and effective bowel cleansing during colonoscopy: a pilot study. Endoscopy 2012;44(8):767-71
-
(2012)
Endoscopy
, vol.44
, Issue.8
, pp. 767-771
-
-
Kiesslich, R.1
Schuster, N.2
Hoffman, A.3
-
3
-
-
84855923025
-
Capsule endoscopy: From current achievements to open challenges
-
Ciuti G, Menciassi A, Dario P. Capsule endoscopy: from current achievements to open challenges. IEEE Rev Biomed Eng 2011;4:59-72
-
(2011)
IEEE Rev Biomed Eng
, vol.4
, pp. 59-72
-
-
Ciuti, G.1
Menciassi, A.2
Dario, P.3
-
5
-
-
79959551142
-
PillCam COLON capsule endoscopy: Recent advances and new insights
-
Adler SN, Metzger YC. PillCam COLON capsule endoscopy: recent advances and new insights. Therap Adv Gastroenterol 2011; 4(4):265-8
-
(2011)
Therap Adv Gastroenterol
, vol.4
, Issue.4
, pp. 265-268
-
-
Adler, S.N.1
Metzger, Y.C.2
-
6
-
-
84910145487
-
First Pillcam Colon 2 capsule images of Whipple's disease: Case report and review of the literature
-
Mateescu BR, Bengus A, Marinescu M, et al. First Pillcam Colon 2 capsule images of Whipple's disease: case report and review of the literature. World J Gastrointest Endosc 2012;4(12):575-8
-
(2012)
World J Gastrointest Endosc
, vol.4
, Issue.12
, pp. 575-578
-
-
Mateescu, B.R.1
Bengus, A.2
Marinescu, M.3
-
7
-
-
70349312782
-
Imaging of the small bowel by capsule endoscopy in Whipple's disease
-
Keane M, Shariff M, Stocks J, et al. Imaging of the small bowel by capsule endoscopy in Whipple's disease. Endoscopy 2009;41(S 02):E139-9
-
(2009)
Endoscopy
, vol.41
, Issue.S 02
, pp. E139-E149
-
-
Keane, M.1
Shariff, M.2
Stocks, J.3
-
8
-
-
84897584516
-
First clinical trial of a newly developed capsule endoscope with panoramic side view for small bowel: A pilot study
-
Friedrich K, Gehrke S, Stremmel W, Sieg A. First clinical trial of a newly developed capsule endoscope with panoramic side view for small bowel: a pilot study. J Gastroenterol Hepatol 2013;28(9):1496-501
-
(2013)
J Gastroenterol Hepatol
, vol.28
, Issue.9
, pp. 1496-1501
-
-
Friedrich, K.1
Gehrke, S.2
Stremmel, W.3
Sieg, A.4
-
9
-
-
58649097129
-
First clinical trial of the 'MiRo' capsule endoscope by using a novel transmission technology: Electric-field propagation
-
Bang S, Park JY, Jeong S, et al. First clinical trial of the 'MiRo' capsule endoscope by using a novel transmission technology: electric-field propagation. Gastrointest Endosc 2009;69(2):253-9
-
(2009)
Gastrointest Endosc
, vol.69
, Issue.2
, pp. 253-259
-
-
Bang, S.1
Park, J.Y.2
Jeong, S.3
-
10
-
-
0036275852
-
Patient pain during colonoscopy: An analysis using real-time magnetic endoscope imaging
-
Shah SG, Brooker JC, Thapar C, et al. Patient pain during colonoscopy: an analysis using real-time magnetic endoscope imaging. Endoscopy 2002;34(6):435-40
-
(2002)
Endoscopy
, vol.34
, Issue.6
, pp. 435-440
-
-
Shah, S.G.1
Brooker, J.C.2
Thapar, C.3
-
12
-
-
58049211854
-
Pinch force and forearm-muscle load during routine colonoscopy: A pilot study
-
Shergill AK, Asundi KR, Barr A, et al. Pinch force and forearm-muscle load during routine colonoscopy: a pilot study. Gastrointest Endosc 2009;69(1):142-6
-
(2009)
Gastrointest Endosc
, vol.69
, Issue.1
, pp. 142-146
-
-
Shergill, A.K.1
Asundi, K.R.2
Barr, A.3
-
14
-
-
79958012679
-
High cecal intubation rates with a new computer-assisted colonoscope: A feasibility study
-
Groth S, Rex DK, Rosch T, Hoepffner N. High cecal intubation rates with a new computer-assisted colonoscope: a feasibility study. Am J Gastroenterol 2011;106(6): 1075-80
-
(2011)
Am J Gastroenterol
, vol.106
, Issue.6
, pp. 1075-1080
-
-
Groth, S.1
Rex, D.K.2
Rosch, T.3
Hoepffner, N.4
-
15
-
-
79954708068
-
Determining scope position during colonoscopy without use of ionizing radiation or magnetic imaging: The enhanced mapping ability of the NeoGuide endoscopy system
-
Striegel J, Jakobs R, Dam JV, et al. Determining scope position during colonoscopy without use of ionizing radiation or magnetic imaging: the enhanced mapping ability of the NeoGuide endoscopy system. Surg Endosc 2011;25(2): 636-40
-
(2011)
Surg Endosc
, vol.25
, Issue.2
, pp. 636-640
-
-
Striegel, J.1
Jakobs, R.2
Dam, J.V.3
-
17
-
-
84871616320
-
Surgical evaluation of a novel tethered robotic capsule endoscope using micro-patterned treads
-
Sliker L, Kern M, Schoen J, Rentschler M. Surgical evaluation of a novel tethered robotic capsule endoscope using micro-patterned treads. Surg Endosc 2012; 26(10):2862-9
-
(2012)
Surg Endosc
, vol.26
, Issue.10
, pp. 2862-2869
-
-
Sliker, L.1
Kern, M.2
Schoen, J.3
Rentschler, M.4
-
18
-
-
70350231536
-
A new mechanism for mesoscale legged locomotion in compliant tubular environments
-
Valdastri P, Webster RJ, Quaglia C, et al. A new mechanism for mesoscale legged locomotion in compliant tubular environments. IEEE Trans Robot 2009; 25(5):1047-57
-
(2009)
IEEE Trans Robot
, vol.25
, Issue.5
, pp. 1047-1057
-
-
Valdastri, P.1
Webster, R.J.2
Quaglia, C.3
-
19
-
-
79955816859
-
An approach to the capsule endoscopic robot with active drive motion
-
Gu D, Zhou Y. An approach to the capsule endoscopic robot with active drive motion. J Zhejiang Univ Sci A 2011;12(3):223-31
-
(2011)
J Zhejiang Univ Sci A
, vol.12
, Issue.3
, pp. 223-231
-
-
Gu, D.1
Zhou, Y.2
-
20
-
-
84911901080
-
A study on anchoring ability of three-leg micro intestinal robot
-
Lin W, Yan G. A study on anchoring ability of three-leg micro intestinal robot. Eng 2012;4(8):477-83
-
(2012)
Eng
, vol.4
, Issue.8
, pp. 477-483
-
-
Lin, W.1
Yan, G.2
-
21
-
-
77955699733
-
Active locomotion of a paddling-based capsule endoscope in an in vitro and in vivo experiment (with videos)
-
Kim HM, Yang S, Kim J, et al. Active locomotion of a paddling-based capsule endoscope in an in vitro and in vivo experiment (with videos). Gastrointest Endosc 2010;72(2):381-7
-
(2010)
Gastrointest Endosc
, vol.72
, Issue.2
, pp. 381-387
-
-
Kim, H.M.1
Yang, S.2
Kim, J.3
-
22
-
-
84896879219
-
An integrated system for wireless capsule endoscopy in a liquid-distended stomach
-
De Falco I, Tortora G, Dario P, Menciassi A. An integrated system for wireless capsule endoscopy in a liquid-distended stomach. IEEE Trans Biomed Eng 2014;61(3):794-804
-
(2014)
IEEE Trans Biomed Eng
, vol.61
, Issue.3
, pp. 794-804
-
-
De Falco, I.1
Tortora, G.2
Dario, P.3
Menciassi, A.4
-
23
-
-
83455203408
-
Small intestinal model for electrically propelled capsule endoscopy
-
Woo SH, Kim TW, Mohy-Ud-Din Z, et al. Small intestinal model for electrically propelled capsule endoscopy. Biomed Eng OnLine 2011;10(1):108
-
(2011)
Biomed Eng OnLine
, vol.10
, Issue.1
, pp. 108
-
-
Woo, S.H.1
Kim, T.W.2
Mohy-Ud-Din, Z.3
-
24
-
-
70350546013
-
Functional evaluation of the Endotics system, a new disposable self-propelled robotic colonoscope: In vitro tests and clinical trial
-
Cosentino F, Tumino E, Rubis Passoni G, et al. Functional evaluation of the Endotics system, a new disposable self-propelled robotic colonoscope: in vitro tests and clinical trial. Int J Artif Organs 2009;32(8): 517-27
-
(2009)
Int J Artif Organs
, vol.32
, Issue.8
, pp. 517-527
-
-
Cosentino, F.1
Tumino, E.2
Rubis Passoni, G.3
-
25
-
-
78649702903
-
Endotics system vs colonoscopy for the detection of polyps
-
Tumino E, Sacco R, Bertini M, et al. Endotics system vs colonoscopy for the detection of polyps. World J Gastroenterol 2010;16(43):5452-6
-
(2010)
World J Gastroenterol
, vol.16
, Issue.43
, pp. 5452-5456
-
-
Tumino, E.1
Sacco, R.2
Bertini, M.3
-
26
-
-
84873656680
-
Advanced endoscopic technologies for colorectal cancer screening
-
Obstein KL, Valdastri P. Advanced endoscopic technologies for colorectal cancer screening. World J Gastroenterol 2013; 19(4):431-9
-
(2013)
World J Gastroenterol
, vol.19
, Issue.4
, pp. 431-439
-
-
Obstein, K.L.1
Valdastri, P.2
-
29
-
-
84863530054
-
Magnetic air capsule robotic system: Proof of concept of a novel approach for painless colonoscopy
-
Valdastri P, Ciuti G, Verbeni A, et al. Magnetic air capsule robotic system: proof of concept of a novel approach for painless colonoscopy. Surg Endosc 2012;26(5): 1238-46
-
(2012)
Surg Endosc
, vol.26
, Issue.5
, pp. 1238-1246
-
-
Valdastri, P.1
Ciuti, G.2
Verbeni, A.3
-
31
-
-
84855855944
-
Blinded nonrandomized comparative study of gastric examination with a magnetically guided capsule endoscope and standard videoendoscope
-
Rey JF, Ogata H, Hosoe N, et al. Blinded nonrandomized comparative study of gastric examination with a magnetically guided capsule endoscope and standard videoendoscope. Gastrointest Endosc 2012; 75(2):373-81
-
(2012)
Gastrointest Endosc
, vol.75
, Issue.2
, pp. 373-381
-
-
Rey, J.F.1
Ogata, H.2
Hosoe, N.3
-
32
-
-
78650534654
-
Inspection of the human stomach using remote-controlled capsule endoscopy: A feasibility study in healthy volunteers (with videos)
-
Keller J, Fibbe C, Volke F, et al. Inspection of the human stomach using remote-controlled capsule endoscopy: a feasibility study in healthy volunteers (with videos). Gastrointest Endosc 2011; 73(1):22-8
-
(2011)
Gastrointest Endosc
, vol.73
, Issue.1
, pp. 22-28
-
-
Keller, J.1
Fibbe, C.2
Volke, F.3
-
33
-
-
79551570334
-
Magnetically controllable gastrointestinal steering of video capsules
-
Carpi F, Kastelein N, Talcott M, Pappone C. Magnetically controllable gastrointestinal steering of video capsules. IEEE Trans Biomed Eng 2011;58(2):231-4
-
(2011)
IEEE Trans Biomed Eng
, vol.58
, Issue.2
, pp. 231-234
-
-
Carpi, F.1
Kastelein, N.2
Talcott, M.3
Pappone, C.4
-
34
-
-
67649224735
-
Magnetic maneuvering of endoscopic capsules by means of a robotic navigation system
-
Carpi F, Pappone C. Magnetic maneuvering of endoscopic capsules by means of a robotic navigation system. IEEE Trans Biomed Eng 2009;56(5):1482-90
-
(2009)
IEEE Trans Biomed Eng
, vol.56
, Issue.5
, pp. 1482-1490
-
-
Carpi, F.1
Pappone, C.2
-
35
-
-
76349086056
-
Robotic versus manual control in magnetic steering of an endoscopic capsule
-
Ciuti G, Donlin R, Valdastri P, et al. Robotic versus manual control in magnetic steering of an endoscopic capsule. Endoscopy 2010;42(2):148-52
-
(2010)
Endoscopy
, vol.42
, Issue.2
, pp. 148-152
-
-
Ciuti, G.1
Donlin, R.2
Valdastri, P.3
-
36
-
-
77949422045
-
Robotic magnetic steering and locomotion of capsule endoscope for diagnostic and surgical endoluminal procedures
-
Ciuti G, Valdastri P, Menciassi A, Dario P. Robotic magnetic steering and locomotion of capsule endoscope for diagnostic and surgical endoluminal procedures. Robotica 2009;28(2):199-207
-
(2009)
Robotica
, vol.28
, Issue.2
, pp. 199-207
-
-
Ciuti, G.1
Valdastri, P.2
Menciassi, A.3
Dario, P.4
-
37
-
-
84911912764
-
-
Available from
-
VECTOR. Available from: www.vectorproject.com
-
-
-
-
38
-
-
84911902388
-
-
Available from
-
SUPCAM. Available from: www.supcam.eu
-
-
-
-
40
-
-
77957602132
-
In vivo trial of a driving system for a self-propelling capsule endoscope using a magnetic field (with video)
-
Morita E, Ohtsuka N, Shindo Y, et al. In vivo trial of a driving system for a self-propelling capsule endoscope using a magnetic field (with video). Gastrointest Endosc 2010;72(4):836-40
-
(2010)
Gastrointest Endosc
, vol.72
, Issue.4
, pp. 836-840
-
-
Morita, E.1
Ohtsuka, N.2
Shindo, Y.3
-
41
-
-
84857184922
-
A wireless module for vibratory motor control and inertial sensing in capsule endoscopy
-
Ciuti G, Pateromichelakis N, Sfakiotakis M, et al. A wireless module for vibratory motor control and inertial sensing in capsule endoscopy. Procedia Eng 2011;25:92-5
-
(2011)
Procedia Eng
, vol.25
, pp. 92-95
-
-
Ciuti, G.1
Pateromichelakis, N.2
Sfakiotakis, M.3
-
42
-
-
77950593244
-
Design, fabrication, and testing of a capsule with hybrid locomotion for gastrointestinal tract exploration
-
Simi M, Valdastri P, Quaglia C, et al. Design, fabrication, and testing of a capsule with hybrid locomotion for gastrointestinal tract exploration. IEEEASME Trans Mechatron 2010;15(2):170-80
-
(2010)
IEEEASME Trans Mechatron
, vol.15
, Issue.2
, pp. 170-180
-
-
Simi, M.1
Valdastri, P.2
Quaglia, C.3
-
44
-
-
84887030111
-
Wireless powered capsule endoscopy for colon diagnosis and treatment
-
Chen W, Yan G, He S, et al. Wireless powered capsule endoscopy for colon diagnosis and treatment. Physiol Meas 2013;34(11):1545
-
(2013)
Physiol Meas
, vol.34
, Issue.11
, pp. 1545
-
-
Chen, W.1
Yan, G.2
He, S.3
-
46
-
-
79960936192
-
Benefit of a clipping device in use in intestinal bleeding and intestinal leakage
-
Albert JG, Friedrich-Rust M, Woeste G, et al. Benefit of a clipping device in use in intestinal bleeding and intestinal leakage. Gastrointest Endosc 2011;74(2):389-97
-
(2011)
Gastrointest Endosc
, vol.74
, Issue.2
, pp. 389-397
-
-
Albert, J.G.1
Friedrich-Rust, M.2
Woeste, G.3
-
47
-
-
73249116248
-
Endoscopic closure of duodenal perforations by using an over-the-scope clip: A randomized, controlled porcine study
-
von Renteln D, Rudolph HU, Schmidt A, et al. Endoscopic closure of duodenal perforations by using an over-the-scope clip: a randomized, controlled porcine study. Gastrointest Endosc 2010;71(1):131-8
-
(2010)
Gastrointest Endosc
, vol.71
, Issue.1
, pp. 131-138
-
-
Von Renteln, D.1
Rudolph, H.U.2
Schmidt, A.3
-
48
-
-
80054010032
-
OVESCO: A promising system for endoscopic closure of gastrointestinal tract perforations
-
Junquera F, Martínez-Bauer E, Miquel M, et al. [OVESCO: a promising system for endoscopic closure of gastrointestinal tract perforations]. Gastroenterol Hepatol 2011; 34(8):568-72
-
(2011)
Gastroenterol Hepatol
, vol.34
, Issue.8
, pp. 568-572
-
-
Junquera, F.1
Martínez-Bauer, E.2
Miquel, M.3
-
49
-
-
84863915276
-
Retrograde-viewing device improves adenoma detection rate in colonoscopies for surveillance and diagnostic workup
-
Siersema PD, Rastogi A, Leufkens AM, et al. Retrograde-viewing device improves adenoma detection rate in colonoscopies for surveillance and diagnostic workup. World J Gastroenterol 2012;18(26):3400-8
-
(2012)
World J Gastroenterol
, vol.18
, Issue.26
, pp. 3400-3408
-
-
Siersema, P.D.1
Rastogi, A.2
Leufkens, A.M.3
-
50
-
-
84896736760
-
Standard forward-viewing colonoscopy versus full-spectrum endoscopy: An international, multicentre, randomised, tandem colonoscopy trial
-
Gralnek IM, Siersema PD, Halpern Z, et al. Standard forward-viewing colonoscopy versus full-spectrum endoscopy: an international, multicentre, randomised, tandem colonoscopy trial. Lancet Oncol 2014;15(3):353-60
-
(2014)
Lancet Oncol
, vol.15
, Issue.3
, pp. 353-360
-
-
Gralnek, I.M.1
Siersema, P.D.2
Halpern, Z.3
-
51
-
-
84873731726
-
A novel extra-wide-angle-view colonoscope: A simulated pilot study using anatomic colorectal models
-
Uraoka T, Tanaka S, Matsumoto T, et al. A novel extra-wide-angle-view colonoscope: a simulated pilot study using anatomic colorectal models. Gastrointest Endosc 2013;77(3):480-3
-
(2013)
Gastrointest Endosc
, vol.77
, Issue.3
, pp. 480-483
-
-
Uraoka, T.1
Tanaka, S.2
Matsumoto, T.3
-
52
-
-
71649106363
-
An integrated vision system with autofocus for wireless capsular endoscopy
-
Cavallotti C, Piccigallo M, Susilo E, et al. An integrated vision system with autofocus for wireless capsular endoscopy. Sens Actuators Phys 2009;156(1):72-8
-
(2009)
Sens Actuators Phys
, vol.156
, Issue.1
, pp. 72-78
-
-
Cavallotti, C.1
Piccigallo, M.2
Susilo, E.3
-
53
-
-
68349120452
-
Microelectromechanical-system-based variable-focus liquid lens for capsule endoscopes
-
Seo SW, Han S, Seo JH, et al. Microelectromechanical-system-based variable-focus liquid lens for capsule endoscopes. Jpn J Appl Phys 2009;48(5): 052404
-
(2009)
Jpn J Appl Phys
, vol.48
, Issue.5
, pp. 052404
-
-
Seo, S.W.1
Han, S.2
Seo, J.H.3
-
54
-
-
84911897610
-
Novel imaging techniques in gastrointestinal endoscopy in the upper gastrointestinal tract
-
Erondu OF, Editors InTech; Croatia
-
Haidry R, Lovat L. Novel imaging techniques in gastrointestinal endoscopy in the upper gastrointestinal tract. In: Erondu OF, Editors Medical imaging in clinical practice. InTech; Croatia: 2013
-
(2013)
Medical Imaging in Clinical Practice
-
-
Haidry, R.1
Lovat, L.2
-
55
-
-
84874355028
-
Is narrow band imaging superior to high-definition white light endoscopy in the assessment of diminutive colorectal polyps?
-
Singh R, Bhat YM, Thurairajah PH, et al. Is narrow band imaging superior to high-definition white light endoscopy in the assessment of diminutive colorectal polyps? J Gastroenterol Hepatol 2013;28(3):472-8
-
(2013)
J Gastroenterol Hepatol
, vol.28
, Issue.3
, pp. 472-478
-
-
Singh, R.1
Bhat, Y.M.2
Thurairajah, P.H.3
-
56
-
-
84871163943
-
Standard endoscopy with random biopsies versus narrow band imaging targeted biopsies in Barrett's oesophagus: A prospective, international, randomised controlled trial
-
Sharma P, Hawes RH, Bansal A, et al. Standard endoscopy with random biopsies versus narrow band imaging targeted biopsies in Barrett's oesophagus: a prospective, international, randomised controlled trial. Gut 2013;62(1):15-21
-
(2013)
Gut
, vol.62
, Issue.1
, pp. 15-21
-
-
Sharma, P.1
Hawes, R.H.2
Bansal, A.3
-
57
-
-
78649515205
-
A wireless narrowband imaging chip for capsule endoscope
-
Dung LR, Wu YY. A wireless narrowband imaging chip for capsule endoscope. IEEE Trans Biomed Circuits Syst 2010;4(6): 462-8
-
(2010)
IEEE Trans Biomed Circuits Syst
, vol.4
, Issue.6
, pp. 462-468
-
-
Dung, L.R.1
Wu, Y.Y.2
-
58
-
-
84871803577
-
Design and implementation of a wireless capsule suitable for autofluorescence intensity detection in biological tissues
-
Al-Rawhani MA, Chitnis D, Beeley J, et al. Design and implementation of a wireless capsule suitable for autofluorescence intensity detection in biological tissues. IEEE Trans Biomed Eng 2013;60(1):55-62
-
(2013)
IEEE Trans Biomed Eng
, vol.60
, Issue.1
, pp. 55-62
-
-
Al-Rawhani, M.A.1
Chitnis, D.2
Beeley, J.3
-
59
-
-
67349247655
-
Computer-aided detection of bleeding regions for capsule endoscopy images
-
Li B, Meng QH. Computer-aided detection of bleeding regions for capsule endoscopy images. IEEE Trans Biomed Eng 2009; 56(4):1032-9
-
(2009)
IEEE Trans Biomed Eng
, vol.56
, Issue.4
, pp. 1032-1039
-
-
Li, B.1
Meng, Q.H.2
-
60
-
-
84856228161
-
Bleeding detection in wireless capsule endoscopy based on probabilistic neural network
-
Pan G, Yan G, Qiu X, Cui J. Bleeding detection in wireless capsule endoscopy based on probabilistic neural network. J Med Syst 2011;35(6):1477-84
-
(2011)
J Med Syst
, vol.35
, Issue.6
, pp. 1477-1484
-
-
Pan, G.1
Yan, G.2
Qiu, X.3
Cui, J.4
-
62
-
-
84867285668
-
Virtual chromoendoscopy as an adjuvant to capsule endoscopy: A step ahead?
-
Crespo-Pérez L, Vázquez-Sequeiros E. Virtual chromoendoscopy as an adjuvant to capsule endoscopy: a step ahead? Rev Esp Enferm Dig 2012;104(5):227-30
-
(2012)
Rev Esp Enferm Dig
, vol.104
, Issue.5
, pp. 227-230
-
-
Crespo-Pérez, L.1
Vázquez-Sequeiros, E.2
-
63
-
-
58149097640
-
Wireless therapeutic endoscopic capsule: In vivo experiment
-
Valdastri P, Quaglia C, Susilo E, et al. Wireless therapeutic endoscopic capsule: in vivo experiment. Endoscopy 2008;40(12): 979-82
-
(2008)
Endoscopy
, vol.40
, Issue.12
, pp. 979-982
-
-
Valdastri, P.1
Quaglia, C.2
Susilo, E.3
-
64
-
-
79957988670
-
A rotational micro biopsy device for the capsule endoscope
-
Kong K, Cha J, Jeon D, Cho D. A rotational micro biopsy device for the capsule endoscope. In: 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems, 2005. (IROS 2005). 2005. pp 1839-43
-
2005 IEEE/RSJ International Conference on Intelligent Robots and Systems, 2005. (IROS 2005). 2005
, pp. 1839-1843
-
-
Kong, K.1
Cha, J.2
Jeon, D.3
Cho, D.4
-
65
-
-
84864504456
-
A robotic biopsy device for capsule endoscopy
-
Kong K, Jeon D, Yim S, Choi S. A robotic biopsy device for capsule endoscopy. J Med Device 2012;6(3):031004-4
-
(2012)
J Med Device
, vol.6
, Issue.3
, pp. 031004-031014
-
-
Kong, K.1
Jeon, D.2
Yim, S.3
Choi, S.4
-
66
-
-
84885063710
-
Magnetic torsion spring mechanism for a wireless biopsy capsule
-
Simi M, Gerboni G, Menciassi A, Valdastri P. Magnetic torsion spring mechanism for a wireless biopsy capsule. J Med Device 2013;7(4):041009-9
-
(2013)
J Med Device
, vol.7
, Issue.4
, pp. 041009-041019
-
-
Simi, M.1
Gerboni, G.2
Menciassi, A.3
Valdastri, P.4
-
67
-
-
84893262129
-
Biopsy using a magnetic capsule endoscope carrying, releasing and retrieving untethered micro-grippers
-
Yim S, Gultepe E, Gracias DH, Sitti M. Biopsy using a magnetic capsule endoscope carrying, releasing and retrieving untethered micro-grippers. IEEE Trans Biomed Eng 2014;61(2):513-21
-
(2014)
IEEE Trans Biomed Eng
, vol.61
, Issue.2
, pp. 513-521
-
-
Yim, S.1
Gultepe, E.2
Gracias, D.H.3
Sitti, M.4
-
68
-
-
84911902207
-
Wireless robotic capsule for releasing bioadhesive patches in the gastrointestinal tract
-
Quaglia C, Tognarelli S, Sinibaldi E, et al. Wireless robotic capsule for releasing bioadhesive patches in the gastrointestinal tract. J Med Device 2013;8(1):014503-3
-
(2013)
J Med Device
, vol.8
, Issue.1
, pp. 014503-014513
-
-
Quaglia, C.1
Tognarelli, S.2
Sinibaldi, E.3
-
69
-
-
84875517481
-
Wireless capsule endoscope for targeted drug delivery: Mechanics and design considerations
-
Woods SP, Constandinou TG. Wireless capsule endoscope for targeted drug delivery: mechanics and design considerations. IEEE Trans Biomed Eng 2013;60(4):945-53
-
(2013)
IEEE Trans Biomed Eng
, vol.60
, Issue.4
, pp. 945-953
-
-
Woods, S.P.1
Constandinou, T.G.2
-
70
-
-
84880569905
-
Magnetically actuated soft capsule with the multimodal drug release function
-
Yim S, Goyal K, Sitti M. Magnetically actuated soft capsule with the multimodal drug release function. IEEE ASME Trans Mechatron 2013;18(4):1413-18
-
(2013)
IEEE ASME Trans Mechatron
, vol.18
, Issue.4
, pp. 1413-1418
-
-
Yim, S.1
Goyal, K.2
Sitti, M.3
-
71
-
-
84857050980
-
24 versus 48-hour bravo pH monitoring
-
Chander B, Hanley-Williams N, Deng Y, Sheth A. 24 versus 48-hour bravo pH monitoring. J Clin Gastroenterol 2012; 46(3):197-200
-
(2012)
J Clin Gastroenterol
, vol.46
, Issue.3
, pp. 197-200
-
-
Chander, B.1
Hanley-Williams, N.2
Deng, Y.3
Sheth, A.4
-
72
-
-
77954382375
-
Technical problems produced by the Bravo pH test in nonerosive reflux disease patients
-
de Hoyos A, Esparza EA. Technical problems produced by the Bravo pH test in nonerosive reflux disease patients. World J Gastroenterol 2010;16(25):3183-6
-
(2010)
World J Gastroenterol
, vol.16
, Issue.25
, pp. 3183-3186
-
-
De Hoyos, A.1
Esparza, E.A.2
-
73
-
-
76349104841
-
To Bravo or not? A comparison of wireless esophageal pH monitoring and conventional pH catheter to evaluate non-erosive gastroesophageal reflux disease in a multiracial Asian cohort
-
Ang D, Teo EK, Ang TL, et al. To Bravo or not? A comparison of wireless esophageal pH monitoring and conventional pH catheter to evaluate non-erosive gastroesophageal reflux disease in a multiracial Asian cohort. J Dig Dis 2010; 11(1):19-27
-
(2010)
J Dig Dis
, vol.11
, Issue.1
, pp. 19-27
-
-
Ang, D.1
Teo, E.K.2
Ang, T.L.3
-
74
-
-
78650154193
-
Evaluation of gastrointestinal transit in clinical practice: Position paper of the American and European neurogastroenterology and motility societies
-
Rao SSC, Camilleri M, Hasler WL, et al. Evaluation of gastrointestinal transit in clinical practice: position paper of the American and European neurogastroenterology and motility societies. Neurogastroenterol Motil 2011;23(1):8-23
-
(2011)
Neurogastroenterol Motil
, vol.23
, Issue.1
, pp. 8-23
-
-
Rao, S.S.C.1
Camilleri, M.2
Hasler, W.L.3
-
75
-
-
84898045959
-
Reliability of intestinal temperature using an ingestible telemetry pill system during exercise in a hot environment
-
Ruddock AD, Tew GA, Purvis AJ. Reliability of intestinal temperature using an ingestible telemetry pill system during exercise in a hot environment. J Strength Cond Res 2014;28(3):861-9
-
(2014)
J Strength Cond Res
, vol.28
, Issue.3
, pp. 861-869
-
-
Ruddock, A.D.1
Tew, G.A.2
Purvis, A.J.3
-
76
-
-
84892438920
-
Prediction of human core body temperature using non-invasive measurement methods
-
Niedermann R, Wyss E, Annaheim S, et al. Prediction of human core body temperature using non-invasive measurement methods. Int J Biometeorol 2014;58(1):7-15
-
(2014)
Int J Biometeorol
, vol.58
, Issue.1
, pp. 7-15
-
-
Niedermann, R.1
Wyss, E.2
Annaheim, S.3
-
77
-
-
84894493329
-
Influence of thermophysiology on thermal behavior: The essentials of categorization
-
Jacquot CMC, Schellen L, Kingma BR, et al. Influence of thermophysiology on thermal behavior: the essentials of categorization. Physiol Behav 2014;128: 180-7
-
(2014)
Physiol Behav
, vol.128
, pp. 180-187
-
-
Jacquot, C.M.C.1
Schellen, L.2
Kingma, B.R.3
-
78
-
-
84898602371
-
Heat strain and hydration status of surface mine blast crew workers
-
Hunt AP, Parker AW, Stewart IB. Heat strain and hydration status of surface mine blast crew workers. J Occup Environ Med 2014;56(4):409-14
-
(2014)
J Occup Environ Med
, vol.56
, Issue.4
, pp. 409-414
-
-
Hunt, A.P.1
Parker, A.W.2
Stewart, I.B.3
-
79
-
-
84896750678
-
Physiological tolerance times while wearing explosive ordnance disposal protective clothing in simulated environmental extremes
-
Stewart IB, Stewart KL, Worringham CJ, Costello JT. Physiological tolerance times while wearing explosive ordnance disposal protective clothing in simulated environmental extremes. PLoS One 2014; 9(2):e83740
-
(2014)
PLoS One
, vol.9
, Issue.2
, pp. e83740
-
-
Stewart, I.B.1
Stewart, K.L.2
Worringham, C.J.3
Costello, J.T.4
-
80
-
-
84891557780
-
Potential screening benefit of a colorectal imaging capsule that does not require bowel preparation
-
Chatrath H, Rex DK. Potential screening benefit of a colorectal imaging capsule that does not require bowel preparation. J Clin Gastroenterol 2014;48(1):52-4
-
(2014)
J Clin Gastroenterol
, vol.48
, Issue.1
, pp. 52-54
-
-
Chatrath, H.1
Rex, D.K.2
-
81
-
-
84873566611
-
Tethered capsule endomicroscopy enables less invasive imaging of gastrointestinal tract microstructure
-
Gora MJ, Sauk JS, Carruth RW, et al. Tethered capsule endomicroscopy enables less invasive imaging of gastrointestinal tract microstructure. Nat Med 2013;19(2):238-40
-
(2013)
Nat Med
, vol.19
, Issue.2
, pp. 238-240
-
-
Gora, M.J.1
Sauk, J.S.2
Carruth, R.W.3
-
82
-
-
84911916309
-
Magnetic maneuvering of capsule endoscopy: Preliminary phantom tests in an experimental colonic model
-
Pák P, Balogh G, Dubravcsik Z, et al. Magnetic maneuvering of capsule endoscopy: preliminary phantom tests in an experimental colonic model. Z Für Gastroenterol 2013;51-A49
-
(2013)
Z für Gastroenterol
, pp. 51-A49
-
-
Pák, P.1
Balogh, G.2
Dubravcsik, Z.3
-
83
-
-
84877762699
-
High-power lithium ion microbatteries from interdigitated three-dimensional bicontinuous nanoporous electrodes
-
Pikul JH, Gang Zhang H, Cho J, et al. High-power lithium ion microbatteries from interdigitated three-dimensional bicontinuous nanoporous electrodes. Nat Commun 2013;4:1732
-
(2013)
Nat Commun
, vol.4
, pp. 1732
-
-
Pikul, J.H.1
Gang Zhang, H.2
Cho, J.3
|