1
-
-
77954839159
-
Swallowable medical devices for diagnosis and surgery: The state of the art
-
J. L. Toennies, G. Tortora, M. Simi, P. Valdastri, and R. J. Webster, III, "Swallowable medical devices for diagnosis and surgery: The state of the art," J.Mech. Eng. Sci., vol. 224, no. 7, pp. 1397-1414, 2010.
-
(2010)
J.Mech. Eng. Sci.
, vol.224
, Issue.7
, pp. 1397-1414
-
-
Toennies, J.L.1
Tortora, G.2
Simi, M.3
Valdastri, P.4
Iii. Webster, R.J.5
-
2
-
-
33750351699
-
Evaluation of the PillCam Colon capsule in the detection of colonic pathology: Results of the first multicenter, prospective, comparative study
-
DOI 10.1055/s-2006-944832
-
R. Eliakim, Z. Fireman, I. M. Gralnek, K. Yassin, M. Waterman, Y. Kopelman, J. Lachter, B. Koslowsky, and S. N. Adler, "Evaluation of the pillCam colon capsule in the detection of colonic pathology: Results of the first multicenter, prospective, comparative study," Endoscopy, vol. 38, pp. 963-970, 2006. (Pubitemid 44641499)
-
(2006)
Endoscopy
, vol.38
, Issue.10
, pp. 963-970
-
-
Eliakim, R.1
Fireman, Z.2
Gralnek, I.M.3
Yassin, K.4
Waterman, M.5
Kopelman, Y.6
Lachter, J.7
Koslowsky, B.8
Adler, S.N.9
-
3
-
-
33749323222
-
Diagnostic colonoscopy: The end is coming
-
DOI 10.1053/j.gastro.2006.08.070, PII S0016508506019858
-
S. Bar-Meir and M. B. Wallace, "Diagnostic colonoscopy: The end is coming," Gastroenterology, vol. 131, pp. 992-994, 2006. (Pubitemid 44498723)
-
(2006)
Gastroenterology
, vol.131
, Issue.4
, pp. 992-994
-
-
Bar-Meir, S.1
Wallace, M.B.2
-
4
-
-
84855923025
-
Capsule endoscopy: From current achievements to open challenges
-
G. Ciuti, A. Menciassi, and P. Dario, "Capsule endoscopy: From current achievements to open challenges," IEEE Rev. Biomed. Eng., vol. 4, pp. 59-72, 2011.
-
(2011)
IEEE Rev. Biomed. Eng.
, vol.4
, pp. 59-72
-
-
Ciuti, G.1
Menciassi, A.2
Dario, P.3
-
5
-
-
77949872845
-
A reconfigurable modular robotic endoluminal surgical system: Vision and preliminary results
-
K. Harada, D. Oetomo, E. Susilo, A. Menciassi, D. Daney, J. P. Merlet, and P. Dario, "A reconfigurable modular robotic endoluminal surgical system: Vision and preliminary results," Robotica, vol. 28, pp. 171-183, 2009.
-
(2009)
Robotica
, vol.28
, pp. 171-183
-
-
Harada, K.1
Oetomo, D.2
Susilo, E.3
Menciassi, A.4
Daney, D.5
Merlet, J.P.6
Dario, P.7
-
6
-
-
84864204614
-
Advanced technologies for gastrointestinal endoscopy
-
P. Valdastri, M. Simi, and R. J. Webster, III, "Advanced technologies for gastrointestinal endoscopy," Annu. Rev. Biomed. Eng., vol. 14, pp. 397-429, 2012.
-
(2012)
Annu. Rev. Biomed. Eng.
, vol.14
, pp. 397-429
-
-
Valdastri, P.1
Simi, M.2
Iii. Webster, R.J.3
-
7
-
-
84855855944
-
Blinded nonrandomized comparative study of gastric examination with a magnetically guided capsule endoscope and standard videoendoscope
-
J. Rey, H. Ogata, N. Hosoe, K. Ohtsuka, N. Ogata, K. Ikeda, H. Aihara, I. Pangtay, T. Hibi, S. Kudo, and H. Tajiri, "Blinded nonrandomized comparative study of gastric examination with a magnetically guided capsule endoscope and standard videoendoscope," Gastrointestinal Endoscopy, vol. 75, no. 2, pp. 373-381, 2012.
-
(2012)
Gastrointestinal Endoscopy
, vol.75
, Issue.2
, pp. 373-381
-
-
Rey, J.1
Ogata, H.2
Hosoe, N.3
Ohtsuka, K.4
Ogata, N.5
Ikeda, K.6
Aihara, H.7
Pangtay, I.8
Hibi, T.9
Kudo, S.10
Tajiri, H.11
-
8
-
-
84867428327
-
Method for navigation and control of a magnetically guided capsule endoscope in the human stomach
-
Roma, Italy
-
H. Keller, A. Juloski, H. Kawano, M. Bechtold, A. Kimura, H. Takizawa, and R. Kuth, "Method for navigation and control of a magnetically guided capsule endoscope in the human stomach," in Proc. IEEE RAS/EMBS Int. Conf. Biomed. Robot. Biomechatronics, Roma, Italy, 2012, pp. 859-865.
-
(2012)
Proc. IEEE RAS/EMBS Int. Conf. Biomed. Robot. Biomechatronics
, pp. 859-865
-
-
Keller, H.1
Juloski, A.2
Kawano, H.3
Bechtold, M.4
Kimura, A.5
Takizawa, H.6
Kuth, R.7
-
9
-
-
78650534654
-
Inspection of the human stomach using remote-controlled capsule endoscopy: A feasibility study in healthy volunteers (with videos)
-
J. Keller, C. Fibbe, F. Volke, J. Gerber, A. C. Mosse, M. Reimann-Zawadzki, E. Rabinovitz, P. Layer, D. Schmitt, V. Andresen, U. Rosien, and P. Swain, "Inspection of the human stomach using remote-controlled capsule endoscopy: A feasibility study in healthy volunteers (with videos)," Gastrointestinal Endoscpoy, vol. 73, no. 1, pp. 22-28, 2011.
-
(2011)
Gastrointestinal Endoscpoy
, vol.73
, Issue.1
, pp. 22-28
-
-
Keller, J.1
Fibbe, C.2
Volke, F.3
Gerber, J.4
Mosse, A.C.5
Reimann-Zawadzki, M.6
Rabinovitz, E.7
Layer, P.8
Schmitt, D.9
Andresen, V.10
Rosien, U.11
Swain, P.12
-
10
-
-
84857030080
-
Design and rolling locomotion of a magnetically actuated soft capsule endoscope
-
Feb.
-
S. Yim and M. Sitti, "Design and rolling locomotion of a magnetically actuated soft capsule endoscope," IEEE Trans. Robot., vol. 28, no. 1, pp. 183-194, Feb. 2012.
-
(2012)
IEEE Trans. Robot.
, vol.28
, Issue.1
, pp. 183-194
-
-
Yim, S.1
Sitti, M.2
-
11
-
-
70350367416
-
Propeller-based wireless device for active capsular endoscopy in the gastric district
-
G. Tortora, P. Valdastri, E. Susilo, A. Menciassi, P. Dario, F. Rieber, and M. O. Schurr, "Propeller-based wireless device for active capsular endoscopy in the gastric district," Minimally Invasive Therapy, vol. 18, pp. 280-290, 2009.
-
(2009)
Minimally Invasive Therapy
, vol.18
, pp. 280-290
-
-
Tortora, G.1
Valdastri, P.2
Susilo, E.3
Menciassi, A.4
Dario, P.5
Rieber, F.6
Schurr, M.O.7
-
12
-
-
70350231536
-
A new mechanism for mesoscale legged locomotion in compliant tubular environments
-
Oct.
-
P. Valdastri, R. J. Webster, III, C. Quaglia, M. Quirini, A. Menciassi, and P. Dario, "A new mechanism for mesoscale legged locomotion in compliant tubular environments," IEEE Trans. Robot., vol. 25, no. 5, pp. 1047-1057, Oct. 2009.
-
(2009)
IEEE Trans. Robot.
, vol.25
, Issue.5
, pp. 1047-1057
-
-
Valdastri, P.1
Webster, R.J.2
Iii. Quaglia, C.3
Quirini, M.4
Menciassi, A.5
Dario, P.6
-
13
-
-
34250782760
-
Evaluation of the critical stroke of an earthworm-like robot for capsule endoscopes
-
DOI 10.1243/09544119JEIM134
-
J. Kwon, S. Park, J. Park, and B. Kim, "Evaluation of the critical stroke of an earthworm-like robot for capsule endoscopes," Proc. Inst. Mech E, Part H: J. Eng. Med., vol. 221, pp. 397-405, 2007. (Pubitemid 46958916)
-
(2007)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.221
, Issue.4
, pp. 397-405
-
-
Kwon, J.1
Park, S.2
Park, J.3
Kim, B.4
-
14
-
-
33748325658
-
A paddling based locomotive mechanism for capsule endoscopes
-
DOI 10.1007/BF02916000
-
S. Park,H. Park, S. Park, and B. Kim, "A paddling based locomotive mechanism for capsule endoscopes," J. Mech. Sci. Technol., vol. 20, pp. 1012-1018, 2006. (Pubitemid 44326640)
-
(2006)
Journal of Mechanical Science and Technology
, vol.20
, Issue.7
, pp. 1012-1018
-
-
Park, S.1
Park, H.2
Park, S.3
Kim, B.4
-
15
-
-
33750045931
-
Miniature endoscopie capsule robot using biomimetic micro-patterned adhesives
-
DOI 10.1109/BIOROB.2006.1639068, 1639068, Proceedings of the First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006, BioRob 2006
-
M. Karagozler, E. Cheung, J. Kwon, and M. Sitti, "Miniature endoscopic capsule robot using biomimetic micro-patterned adhesives," in Proc. IEEE/RAS-EMBS Int. Conf. Biomed. Robot. Biomech., Pisa, Italy, 2006, pp. 105-111. (Pubitemid 44931105)
-
(2006)
Proceedings of the First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006, BioRob 2006
, vol.2006
, pp. 105-111
-
-
Karagozler, M.E.1
Cheung, E.2
Kwon, J.3
Sitti, M.4
-
16
-
-
58149271167
-
A legged anchoringmechanism for capsule endoscopes using micropatterned adhesives
-
Dec.
-
P. Glass, E. Cheung, andM. Sitti, "A legged anchoringmechanism for capsule endoscopes using micropatterned adhesives," IEEE Trans. Biomed. Eng., vol. 55, no. 12, pp. 2759-2767, Dec. 2008.
-
(2008)
IEEE Trans. Biomed. Eng.
, vol.55
, Issue.12
, pp. 2759-2767
-
-
Glass, P.1
Cheung, E.2
Sitti, M.3
-
17
-
-
73349113576
-
Bowel preparation for colonoscopy with sodium phosphate solution versus polyethylene glycol-based lavage: A multicenter trial
-
S. Schanz, W. Kruis, O. Mickisch, B. Kuppers, P. Berg, B. Frick, G. Heiland, D. Huppe, B. Schenck, H. Horstkotte, and A. Winkler, "Bowel preparation for colonoscopy with sodium phosphate solution versus polyethylene glycol-based lavage: A multicenter trial," Diagnostic Therapeutic Endoscopy, vol. 2008, 713521, 2008.
-
(2008)
Diagnostic Therapeutic Endoscopy
, pp. 713521
-
-
Schanz, S.1
Kruis, W.2
Mickisch, O.3
Kuppers, B.4
Berg, P.5
Frick, B.6
Heiland, G.7
Huppe, D.8
Schenck, B.9
Horstkotte, H.10
Winkler, A.11
-
18
-
-
63049094603
-
Single and multiple robotic capsules for endoluminal diagnosis and surgery
-
Scottsdale, AZ, USA
-
A. Menciassi, P. Valdastri, K. Harada, and P. Dario, "Single and multiple robotic capsules for endoluminal diagnosis and surgery," in Proc. IEEE RAS-EMBS Int. Conf. Biomed. Robotics Biomech., Scottsdale, AZ, USA, 2008, pp. 238-243.
-
(2008)
Proc. IEEE RAS-EMBS Int. Conf. Biomed. Robotics Biomech.
, pp. 238-243
-
-
Menciassi, A.1
Valdastri, P.2
Harada, K.3
Dario, P.4
-
19
-
-
80051684454
-
A novel magnetic actuation system for miniature swimming robots
-
Aug.
-
P. Valdastri, E. Sinibaldi, S. Caccavaro, G. Tortora, A. Menciassi, and P. Dario, "A novel magnetic actuation system for miniature swimming robots," IEEE Trans. Robot., vol. 27, no. 4, pp. 769-779, Aug. 2011.
-
(2011)
IEEE Trans. Robot.
, vol.27
, Issue.4
, pp. 769-779
-
-
Valdastri, P.1
Sinibaldi, E.2
Caccavaro, S.3
Tortora, G.4
Menciassi, A.5
Dario, P.6
-
20
-
-
77952803144
-
Methodology of dynamic actuation for flexible magnetic actuator and biomimetic robotics application
-
Jun.
-
S. H. Kim, S. Hashi, andK. Ishiyama, "Methodology of dynamic actuation for flexible magnetic actuator and biomimetic robotics application," IEEE Trans. Magn., vol. 46, no. 6, pp. 1366-1369, Jun. 2010.
-
(2010)
IEEE Trans. Magn.
, vol.46
, Issue.6
, pp. 1366-1369
-
-
Kim, S.H.1
Hashi, S.2
Ishiyama, K.3
-
21
-
-
40949130554
-
Electrostatically actuated robotic fish: Design and control for high-mobility open-loop swimming
-
DOI 10.1109/TRO.2007.913989
-
Z. G. Zhang, N. Yamashita, M. Gondo, A. Yamamoto, and T. Higuchi, "Electrostatically actuated robotic fish: Design and control for highmobility open-loop swimming," IEEE Trans. Robot., vol. 24, no. 1, pp. 118-129, Feb. 2008. (Pubitemid 351411202)
-
(2008)
IEEE Transactions on Robotics
, vol.24
, Issue.1
, pp. 118-129
-
-
Zhang, Z.G.1
Yamashita, N.2
Gondo, M.3
Yamamoto, A.4
Higuchi, T.5
-
22
-
-
36349005362
-
Mechanism and control of a novel type microrobot for biomedical application
-
DOI 10.1109/ROBOT.2007.363785, 4209090, 2007 IEEE International Conference on Robotics and Automation, ICRA'07
-
S. Guo and Q. Pan, "Mechanism and control of a novel type microrobot for biomedical applications," in Proc. IEEE Int. Conf. Robot. Autom., 2007, pp. 187-192. (Pubitemid 350140185)
-
(2007)
Proceedings - IEEE International Conference on Robotics and Automation
, pp. 187-192
-
-
Guo, S.1
Pan, Q.2
-
23
-
-
72849128807
-
Characterizing the swimming properties of artificial bacterial flagella
-
L. Zhang, J. J. Abbott, L. Dong, K. E. Peyer, B. E. Kratochvil, H. Zhang, C. Bergeles, and B. J. Nelson, "Characterizing the swimming properties of artificial bacterial flagella," Nano Lett., vol. 9, pp. 3663-3667, 2009.
-
(2009)
Nano Lett.
, vol.9
, pp. 3663-3667
-
-
Zhang, L.1
Abbott, J.J.2
Dong, L.3
Peyer, K.E.4
Kratochvil, B.E.5
Zhang, H.6
Bergeles, C.7
Nelson, B.J.8
-
24
-
-
19644395781
-
E. Coli inspired propulsion for swimming microrobots
-
B. Behkam and M. Sitti, "E. Coli inspired propulsion for swimming microrobots," in Proc. IMECE Int. Mech. Eng. Conf., 2004, pp. 1037-1042.
-
(2004)
Proc. IMECE Int. Mech. Eng. Conf.
, pp. 1037-1042
-
-
Behkam, B.1
Sitti, M.2
-
25
-
-
84555194900
-
Micro-swimming without flagella: Propulsion by internal structures
-
K. M. Ehlers and J. Koiller, "Micro-swimming without flagella: Propulsion by internal structures," Reg. Chaotic Dyn., vol. 16, no. 6, pp. 623-652, 2011.
-
(2011)
Reg. Chaotic Dyn.
, vol.16
, Issue.6
, pp. 623-652
-
-
Ehlers, K.M.1
Koiller, J.2
-
26
-
-
84857786411
-
MRI driven magnetic microswimmers
-
G. Ḱosa, P. Jakab, G. Sźekely, and N. Hata, "MRI driven magnetic microswimmers," Biomed. Microdevices, vol. 14, pp. 165-178, 2012.
-
(2012)
Biomed. Microdevices
, vol.14
, pp. 165-178
-
-
Ḱosa, G.1
Jakab, P.2
Sźekely, G.3
Hata, N.4
-
27
-
-
77957220791
-
At a watershed? Technical developments in wireless capsule endoscopy
-
P. Swain, "At a watershed? Technical developments in wireless capsule endoscopy," J. Digestive Diseases, vol. 11, pp. 259-265, 2010.
-
(2010)
J. Digestive Diseases
, vol.11
, pp. 259-265
-
-
Swain, P.1
-
28
-
-
84896857334
-
-
PillCam ESO 2 G. I. Co., Yoqneam, Israel
-
PillCam ESO 2, G. I. Co., Yoqneam, Israel, 2007.
-
(2007)
-
-
-
30
-
-
84856904759
-
Vision system for high frame rate wireless capsule endoscope
-
M. Vatteroni, C. Cavallotti, M. Silvestri, P. Valdastri, A. Menciassi, P. Dario, P. Merlino, and A. Abramo, "Vision system for high frame rate wireless capsule endoscope," in Proc. IEEE Sensors, 2011, pp. 809-812.
-
(2011)
Proc. IEEE Sensors
, pp. 809-812
-
-
Vatteroni, M.1
Cavallotti, C.2
Silvestri, M.3
Valdastri, P.4
Menciassi, A.5
Dario, P.6
Merlino, P.7
Abramo, A.8
-
31
-
-
0343375204
-
Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)
-
ICNIRP Guidelines
-
ICNIRP Guidelines, "Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)," Health Phys., vol. 74, pp. 494-522, 1998.
-
(1998)
Health Phys.
, vol.74
, pp. 494-522
-
-
-
32
-
-
84862969409
-
Swallowable wireless capsule endoscopy: Progress and technical challenges
-
G. Pan and L.Wang, "Swallowable wireless capsule endoscopy: Progress and technical challenges," Hindawi Publ. Corp. Gastroenterol. Res. Practice, vol. 2012, 841691, 2012.
-
(2012)
Hindawi Publ. Corp. Gastroenterol. Res. Practice
, pp. 841691
-
-
Pan, G.1
Wang, L.2
-
33
-
-
0010392354
-
-
New York NY USA: McGraw-Hill
-
B. M. Plavsic, A. E. Robinson, and R. B. Jeffrey, Gastrointestinal Radiology: A Concise Text. New York, NY, USA: McGraw-Hill, 1991, pp. 175-242.
-
(1991)
Gastrointestinal Radiology: A Concise Text
, pp. 175-242
-
-
Plavsic, B.M.1
Robinson, A.E.2
Jeffrey, R.B.3
-
34
-
-
44349105367
-
Transmission power requirements for novel ZigBee implants in the gastrointestinal tract
-
DOI 10.1109/TBME.2008.919117, 10
-
P. Valdastri, A. Menciassi, and P. Dario, "Transmission power Requirements for Novel ZigBee Implants in the Gastrointestinal Tract," IEEE Trans. Biomed. Eng., vol. 55, no. 6, pp. 1705-1710, Jun. 2008. (Pubitemid 351728021)
-
(2008)
IEEE Transactions on Biomedical Engineering
, vol.55
, Issue.6
, pp. 1705-1710
-
-
Valdastri, P.1
Menciassi, A.2
Dario, P.3
-
35
-
-
84896879210
-
Protezione dai campi elettromagnetici non ionizzanti Consiglio Nazionale delle Ricerche, Istituto di Ricerca sulle Onde Elettromagnetiche
-
Book Edited by Centro Stampa 2P, Firenze
-
D. Andreuccetti, M. Bini, A. Checcucci, A. Ignesti, L. Millanta, R. Olmi, and N. Rubino, "Protezione dai campi elettromagnetici non ionizzanti," Consiglio Nazionale delle Ricerche, Istituto di Ricerca sulle Onde Elettromagnetiche "Nello Carrara", Book Edited by Centro Stampa 2P, Firenze, 2001.
-
(2001)
Nello Carrara
-
-
Andreuccetti, D.1
Bini, M.2
Checcucci, A.3
Ignesti, A.4
Millanta, L.5
Olmi, R.6
Rubino, N.7
-
37
-
-
35548945344
-
In situ characterization of two wireless transmission schemes for ingestible capsules
-
DOI 10.1109/TBME.2007.895105
-
L. Wang, T. D. Drysdale, and D. R. S. Cumming, "In-situ characterization of two wireless transmission schemes for ingestible capsules," IEEE Trans. Biomed. Eng., vol. 54, no. 11, pp. 2020-2027, Nov. 2007. (Pubitemid 350006071)
-
(2007)
IEEE Transactions on Biomedical Engineering
, vol.54
, Issue.11
, pp. 2020-2027
-
-
Wang, L.1
Drysdale, T.D.2
Cumming, D.R.S.3
|