메뉴 건너뛰기




Volumn 4, Issue 6 PART 2, 2010, Pages 462-468

A wireless narrowband imaging chip for capsule endoscope

Author keywords

Capsule endoscope; complementary metaloxide semiconductor (CMOS) sensor; gastrointestinal image; narrowband image (NBI)

Indexed keywords

AVERAGE CURRENTS; CAPSULE ENDOSCOPES; CMOS SENSORS; COMMERCIAL OF THE SHELVES; COMPLEMENTARY METAL OXIDE SEMICONDUCTORS; DIAGNOSTIC TOOLS; DUAL MODES; FRAME RATE; GASTROINTESTINAL IMAGE; GASTROINTESTINAL TRACT; HUMAN TONGUE; NARROW BANDS; NARROWBAND IMAGING; POWER DISSIPATION REDUCTION; POWER SUPPLY; RF TRANSMITTER; SMALL INTESTINE; WHITE LIGHT; WIRELESS CAPSULE ENDOSCOPE;

EID: 78649515205     PISSN: 19324545     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBCAS.2010.2079932     Document Type: Conference Paper
Times cited : (33)

References (16)
  • 1
    • 39449129517 scopus 로고    scopus 로고
    • Multifunctional endoscopic imaging system for support of early cancer diagnosis
    • Jan./Feb
    • K. Gono, "Multifunctional endoscopic imaging system for support of early cancer diagnosis", IEEE J. Sel. Topics Quant. Electron, vol. 14, no. 1, pp. 62-69, Jan./Feb. 2008.
    • (2008) IEEE J. Sel. Topics Quant. Electron , vol.14 , Issue.1 , pp. 62-69
    • Gono, K.1
  • 4
    • 22144459018 scopus 로고    scopus 로고
    • Narrow band imaging: A new diagnostic approach to visualize angiogenesis insuperficial neoplasia
    • M. Muto, C. Katada, Y. Sano, and S. Yoshida, "Narrow band imaging: A new diagnostic approach to visualize angiogenesis insuperficial neoplasia", Clin. Gastroent. Hepatol., vol. 3, no. 7, pp. 3:S16-3:S20, 2005.
    • (2005) Clin. Gastroent. Hepatol. , vol.3 , Issue.7
    • Muto, M.1    Katada, C.2    Sano, Y.3    Yoshida, S.4
  • 5
    • 22144437324 scopus 로고    scopus 로고
    • Narrow band imaging in barrett's esophagus
    • P. Sharma, "Narrow band imaging in barrett's esophagus", Clin. Gastroent. Hepatol., vol. 3, no. 7, pp. 3:S21-3:S22, 2005.
    • (2005) Clin. Gastroent. Hepatol. , vol.3 , Issue.7
    • Sharma, P.1
  • 6
    • 0034713363 scopus 로고    scopus 로고
    • Wireless capsule endoscopy
    • May 25
    • G. Iddan, G. Meron, A. Glukhovsky, and P. Swain, "Wireless capsule endoscopy", Nature, vol. 405, pp. 417-418, May 25, 2000.
    • (2000) Nature , vol.405 , pp. 417-418
    • Iddan, G.1    Meron, G.2    Glukhovsky, A.3    Swain, P.4
  • 7
    • 60149085744 scopus 로고    scopus 로고
    • A wireless capsule endoscope system with low-power controlling and processing asic
    • Feb
    • X. Chen, X. Zhang, L. Zhang, X. Li, N. Qi, H. Jiang, and Z. Wang, "A wireless capsule endoscope system with low-power controlling and processing asic", IEEE Trans. Biomed. Syst., vol. 3, no. 1, pp. 11-22, Feb. 2009.
    • (2009) IEEE Trans. Biomed. Syst. , vol.3 , Issue.1 , pp. 11-22
    • Chen, X.1    Zhang, X.2    Zhang, L.3    Li, X.4    Qi, N.5    Jiang, H.6    Wang, Z.7
  • 8
    • 33750831225 scopus 로고    scopus 로고
    • A low-power digital ic design inside the wireless endoscopic capsule
    • Nov
    • X. Xie, G. Li, X. Chen, X. Li, and Z. Wang, "A low-power digital ic design inside the wireless endoscopic capsule", IEEE J. Solid-State Circuits, vol. 41, no. 11, pp. 2390-2400, Nov. 2006.
    • (2006) IEEE J. Solid-State Circuits , vol.41 , Issue.11 , pp. 2390-2400
    • Xie, X.1    Li, G.2    Chen, X.3    Li, X.4    Wang, Z.5
  • 11
    • 56349107000 scopus 로고    scopus 로고
    • Negative capsule endoscopy in patients with obscure gi bleeding predicts low rebleeding rates
    • J. Macdonald, V. Porter, and D. McNamara, "Negative capsule endoscopy in patients with obscure gi bleeding predicts low rebleeding rates", Gastrointest. Endoscopy, vol. 68, no. 6, pp. 1122-1127, 2008.
    • (2008) Gastrointest. Endoscopy , vol.68 , Issue.6 , pp. 1122-1127
    • Macdonald, J.1    Porter, V.2    McNamara, D.3
  • 12
    • 56349148363 scopus 로고    scopus 로고
    • Obscure gi bleeding: Is capsule endoscopy sufficient?
    • L. H. Lai, "Obscure gi bleeding: Is capsule endoscopy sufficient?", Gastrointest. Endoscopy, vol. 68, no. 6, pp. 1128-1130, 2008.
    • (2008) Gastrointest. Endoscopy , vol.68 , Issue.6 , pp. 1128-1130
    • Lai, L.H.1
  • 14
    • 78649517455 scopus 로고    scopus 로고
    • Olympus launches EVIS Lucera Spectrum Video Imaging System for NBI support for normal light imaging and narrow band imaging NBI. Olympus. Online. Available
    • Olympus launches EVIS Lucera Spectrum Video Imaging System for NBI support for normal light imaging and narrow band imaging (NBI). Olympus. [Online]. Available: http://www.olympus-europa.com
  • 15
    • 33744551794 scopus 로고    scopus 로고
    • Color filter arrays: Design and performance analysis
    • Nov
    • R. Lukac and K. N. Plataniotis, "Color filter arrays: Design and performance analysis", IEEE Trans. Consum. Electron., vol. 51, no. 4, pp. 1260-1267, Nov. 2005.
    • (2005) IEEE Trans. Consum. Electron. , vol.51 , Issue.4 , pp. 1260-1267
    • Lukac, R.1    Plataniotis, K.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.