Volumn 55, Issue 2, 2014, Pages 666-673

Comparison of three intraocular pressure measurement methods including biomechanical properties of the cornea

Author keywords

Corneal biomechanics; Intraocular pressure; Tonometry

Indexed keywords

ADULT; ARTICLE; BIOMECHANICS; CENTRAL CORNEAL THICKNESS; COMPARATIVE STUDY; CORNEA; CORNEA EDEMA; CORNEAL PACHYMETRY; CORRELATION COEFFICIENT; FEMALE; GOLDMANN APPLANATION TONOMETER; HUMAN; INTRAOCULAR PRESSURE; INTRAOCULAR PRESSURE MEASURING DEVICE; KERATOCONUS; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; PROSPECTIVE STUDY; SCHEIMPFLUG CAMERA; SLIT LAMP; TONOMETRY; ULTRASOUND PACHYMETER;

EID: 84893304314     PISSN: 01460404     EISSN: 15525783     Source Type: Journal    
DOI: 10.1167/iovs.13-13172     Document Type: Article
Times cited : (79)

References (33)
  • 2
    • 80051897270 scopus 로고    scopus 로고
    • Intraocular pressure control and longterm visual field loss in the Collaborative Initial Glaucoma Treatment Study
    • CIGTS Study Group
    • Musch DC, Gillespie BW, Niziol LM, Lichter PR, Varma R; CIGTS Study Group. Intraocular pressure control and longterm visual field loss in the Collaborative Initial Glaucoma Treatment Study. Ophthalmology. 2011;118:1766-1773.
    • (2011) Ophthalmology. , vol.118 , pp. 1766-1773
    • Musch, D.C.1    Gillespie, B.W.2    Niziol, L.M.3    Lichter, P.R.4    Varma, R.5
  • 3
    • 43749092192 scopus 로고    scopus 로고
    • Effect of cornea material stiffness on measured intraocular pressure
    • Kwon TH, Ghaboussi J, Pecknold DA, Hashash YM. Effect of cornea material stiffness on measured intraocular pressure. J Biomech. 2008;4:1707-1713.
    • (2008) J Biomech. , vol.4 , pp. 1707-1713
    • Kwon, T.H.1    Ghaboussi, J.2    Pecknold, D.A.3    Hashash, Y.M.4
  • 4
    • 48549092622 scopus 로고    scopus 로고
    • Young's modulus in normal corneas and the effect on applanation tonometry
    • Hamilton KE, Pye DC. Young's modulus in normal corneas and the effect on applanation tonometry. Optom Vis Sci. 2008;8:445-450.
    • (2008) Optom Vis Sci. , vol.8 , pp. 445-450
    • Hamilton, K.E.1    Pye, D.C.2
  • 5
    • 13844313434 scopus 로고    scopus 로고
    • Influence of corneal biomechanical properties on intraocular pressure measurement: Quantitative analysis
    • Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg. 2005;31:146-155.
    • (2005) J Cataract Refract Surg. , vol.31 , pp. 146-155
    • Liu, J.1    Roberts, C.J.2
  • 6
    • 84863783517 scopus 로고    scopus 로고
    • Graft biomechanical properties after penetrating keratoplasty in keratoconus
    • Feizi S, Einollahi B, Yazdani S, Hashemloo A. Graft biomechanical properties after penetrating keratoplasty in keratoconus. Cornea. 2012;31:855-858.
    • (2012) Cornea. , vol.31 , pp. 855-858
    • Feizi, S.1    Einollahi, B.2    Yazdani, S.3    Hashemloo, A.4
  • 7
    • 43649095145 scopus 로고    scopus 로고
    • Assessment of true intraocular pressure: The gap between theory and practical data
    • Chihara E. Assessment of true intraocular pressure: the gap between theory and practical data. Surv Ophthalmol. 2008; 53:203-218.
    • (2008) Surv Ophthalmol. , vol.53 , pp. 203-218
    • Chihara, E.1
  • 8
    • 84891659509 scopus 로고    scopus 로고
    • Assessment of intraocular pressure measured by Reichert ocular response analyzer, Goldmann applanation tonometry, and dynamic contour tonometry in healthy individuals
    • Ouyang PB, Li CY, Zhu XH, Duan XC. Assessment of intraocular pressure measured by Reichert ocular response analyzer, Goldmann applanation tonometry, and dynamic contour tonometry in healthy individuals. Int J Ophthalmol. 2012;5:102-107.
    • (2012) Int J Ophthalmol. , vol.5 , pp. 102-107
    • Ouyang, P.B.1    Li, C.Y.2    Zhu, X.H.3    Duan, X.C.4
  • 9
    • 70449195078 scopus 로고
    • Über Applanationstonometrie
    • Goldmann H, Schmidt T. Über Applanationstonometrie. Ophthalmologica. 1957;134:221-242.
    • (1957) Ophthalmologica. , vol.134 , pp. 221-242
    • Goldmann, H.1    Schmidt, T.2
  • 10
    • 62849087073 scopus 로고    scopus 로고
    • Comparison of Goldmann applanation tonometry and dynamic contour tonometry in the measurement of intraocular pressure in eyes with different corneal thicknesses
    • Roszkowska AM, De Grazia L, Cirone M, Ferreri G. Comparison of Goldmann applanation tonometry and dynamic contour tonometry in the measurement of intraocular pressure in eyes with different corneal thicknesses. Ophthalmologica. 2009;223:244-249.
    • (2009) Ophthalmologica. , vol.223 , pp. 244-249
    • Roszkowska, A.M.1    De Grazia, L.2    Cirone, M.3    Ferreri, G.4
  • 11
    • 0032945114 scopus 로고    scopus 로고
    • Tonometry and corneal thickness
    • Brubaker RF. Tonometry and corneal thickness. Arch Ophthalmol. 1999;117:104-105.
    • (1999) Arch Ophthalmol. , vol.117 , pp. 104-105
    • Brubaker, R.F.1
  • 13
    • 0030318702 scopus 로고    scopus 로고
    • A new electromechanical method for measuring intraocular pressure
    • Kontiola AI. A new electromechanical method for measuring intraocular pressure. Doc Ophthalmol. 1997;93:265-276.
    • (1997) Doc Ophthalmol. , vol.93 , pp. 265-276
    • Kontiola, A.I.1
  • 15
  • 17
    • 84872175054 scopus 로고    scopus 로고
    • Corneal deformation measurement using Scheimpflug noncontact tonometry
    • Hon Y, Lam AK. Corneal deformation measurement using Scheimpflug noncontact tonometry. Optom Vis Sci. 2013; 90:e1-e8.
    • (2013) Optom Vis Sci. , vol.90
    • Hon, Y.1    Lam, A.K.2
  • 18
    • 84863419381 scopus 로고    scopus 로고
    • Relationship between corneal biomechanical properties, central corneal thickness, and intraocular pressure across the spectrum of glaucoma
    • Kaushik S, Pandav SS, Banger A, Aggarwal K, Gupta A. Relationship between corneal biomechanical properties, central corneal thickness, and intraocular pressure across the spectrum of glaucoma. Am J Ophthalmol. 2012;153: 840-849.
    • (2012) Am J Ophthalmol. , vol.153 , pp. 840-849
    • Kaushik, S.1    Pandav, S.S.2    Banger, A.3    Aggarwal, K.4    Gupta, A.5
  • 19
    • 84862811896 scopus 로고    scopus 로고
    • Correlation between corneal biomechanical properties, applanation tonometry and direct intracameral tonometry
    • Yu AY, Duan SF, Zhao YE, et al. Correlation between corneal biomechanical properties, applanation tonometry and direct intracameral tonometry. Br J Ophthalmol. 2012;96: 640-644.
    • (2012) Br J Ophthalmol. , vol.96 , pp. 640-644
    • Yu, A.Y.1    Duan, S.F.2    Zhao, Y.E.3
  • 20
    • 34548695879 scopus 로고    scopus 로고
    • Comparison of IOP measurements between ORA and GAT in normal Chinese
    • Lam A, Chen D, Chiu R, Chui WS. Comparison of IOP measurements between ORA and GAT in normal Chinese. Optom Vis Sci. 2007;84:909-914.
    • (2007) Optom Vis Sci. , vol.84 , pp. 909-914
    • Lam, A.1    Chen, D.2    Chiu, R.3    Chui, W.S.4
  • 21
    • 77954743809 scopus 로고    scopus 로고
    • Comparison of three methods of intraocular pressure measurement and their relation to central corneal thickness
    • Carbonaro F, Andrew T, Mackey DA, Spector TD, Hammond CJ. Comparison of three methods of intraocular pressure measurement and their relation to central corneal thickness. Eye (Lond). 2010;24:1165-1170.
    • (2010) Eye (Lond). , vol.24 , pp. 1165-1170
    • Carbonaro, F.1    Andrew, T.2    McKey, D.A.3    Spector, T.D.4    Hammond, C.J.5
  • 22
    • 84880318522 scopus 로고    scopus 로고
    • Comparison of the new rebound tonometer with Goldmann applanation tonometer in a clinical setting
    • Kim KN, Jeoung JW, Park KH, Yang MK, Kim DM. Comparison of the new rebound tonometer with Goldmann applanation tonometer in a clinical setting. Acta Ophthalmol. 2013;91:e392-e396.
    • (2013) Acta Ophthalmol. , vol.91
    • Kim, K.N.1    Jeoung, J.W.2    Park, K.H.3    Yang, M.K.4    Kim, D.M.5
  • 23
    • 79955611374 scopus 로고    scopus 로고
    • Repeatability of intra-ocular pressure and central corneal thickness measurements provided by a non-contact method of tonometry and pachymetry
    • Lomoriello DS, Lombardo M, Tranchina L, et al. Repeatability of intra-ocular pressure and central corneal thickness measurements provided by a non-contact method of tonometry and pachymetry. Graefes Arch Clin Exp Ophthalmol. 2011;249:429-434.
    • (2011) Graefes Arch Clin Exp Ophthalmol. , vol.249 , pp. 429-434
    • Lomoriello, D.S.1    Lombardo, M.2    Tranchina, L.3
  • 25
    • 77949658771 scopus 로고    scopus 로고
    • Intraocular pressure measurement precision with the Goldmann applanation, dynamic contour, and ocular response analyzer tonometers
    • Kotecha A, White E, Schlottmann PG, Garway-Heath DF. Intraocular pressure measurement precision with the Goldmann applanation, dynamic contour, and ocular response analyzer tonometers. Ophthalmology. 2010;117:730-737.
    • (2010) Ophthalmology. , vol.117 , pp. 730-737
    • Kotecha, A.1    White, E.2    Schlottmann, P.G.3    Garway-Heath, D.F.4
  • 26
    • 84874744915 scopus 로고    scopus 로고
    • A new tonometer-the Corvis ST tonometer: Clinical comparison with noncontact and Goldmann applanation tonometers
    • Hong J, Xu J, Wei A, et al. A new tonometer-the Corvis ST tonometer: clinical comparison with noncontact and Goldmann applanation tonometers. Invest Ophthalmol Vis Sci. 2013;54:659-665.
    • (2013) Invest Ophthalmol Vis Sci. , vol.54 , pp. 659-665
    • Hong, J.1    Xu, J.2    Wei, A.3
  • 27
    • 79955677661 scopus 로고    scopus 로고
    • Assessment of central corneal thickness using OCT, ultrasound, optical low coherence reflectometry and Scheimpflug pachymetry
    • Beutelspacher SC, Serbecic N, Scheuerle AF. Assessment of central corneal thickness using OCT, ultrasound, optical low coherence reflectometry and Scheimpflug pachymetry. Eur J Ophthalmol. 2011;21:132-137.
    • (2011) Eur J Ophthalmol. , vol.21 , pp. 132-137
    • Beutelspacher, S.C.1    Serbecic, N.2    Scheuerle, A.F.3
  • 31
    • 84857837205 scopus 로고    scopus 로고
    • Adjusting intraocular pressure for central corneal thickness does not improve prediction models for primary open-angle glaucoma
    • Ocular Hypertension Treatment Study Group
    • Brandt JD, Gordon MO, Gao F, Beiser JA, Miller JP, Kass MA; Ocular Hypertension Treatment Study Group. Adjusting intraocular pressure for central corneal thickness does not improve prediction models for primary open-angle glaucoma. Ophthalmology. 2012;119:437-442.
    • (2012) Ophthalmology. , vol.119 , pp. 437-442
    • Brandt, J.D.1    Gordon, M.O.2    Gao, F.3    Beiser, J.A.4    Miller, J.P.5    Kass, M.A.6
  • 32
    • 84882332493 scopus 로고    scopus 로고
    • Repeatability of ocular biomechanical data measurements with a Scheimpflug-based noncontact device on normal corneas
    • Nemeth G, Hassan Z, Csutak A, Szalai E, Berta A, Modis L Jr. Repeatability of ocular biomechanical data measurements with a Scheimpflug-based noncontact device on normal corneas. J Refract Surg. 2013;29:558-563.
    • (2013) J Refract Surg. , vol.29 , pp. 558-563
    • Nemeth, G.1    Hassan, Z.2    Csutak, A.3    Szalai, E.4    Berta, A.5    Modis Jr., L.6
  • 33
    • 84873059709 scopus 로고    scopus 로고
    • Biomechanical profile of the cornea in primary congenital glaucoma
    • Gatzioufas Z, Labiris G, Stachs O, et al. Biomechanical profile of the cornea in primary congenital glaucoma. Acta Ophthalmol. 2013;91:e29-e34.
    • (2013) Acta Ophthalmol. , vol.91
    • Gatzioufas, Z.1    Labiris, G.2    Stachs, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.