메뉴 건너뛰기




Volumn 31, Issue 8, 2012, Pages 855-858

Graft biomechanical properties after penetrating keratoplasty in keratoconus

Author keywords

corneal graft biomechanical properties; intraocular pressure; keratoconus; ocular response analyzer; penetrating keratoplasty

Indexed keywords

ADULT; ANALYZER; ARTICLE; BIOMECHANICS; CLINICAL ARTICLE; CORNEA; CORNEA TRANSPLANTATION; CROSS-SECTIONAL STUDY; EYE; FEMALE; FOLLOW UP; GOLDMANN APPLANATION TONOMETRY; HUMAN; INTRAOCULAR PRESSURE; KERATOCONUS; KERATOMETRY; MALE; MEDICAL TECHNOLOGY; MULTIVARIATE ANALYSIS; OCULAR RESPONSE ANALYZER; PENETRATING KERATOPLASTY; PRIORITY JOURNAL; REGRESSION ANALYSIS; TONOMETER; TONOMETRY; ULTRASOUND;

EID: 84863783517     PISSN: 02773740     EISSN: 15364798     Source Type: Journal    
DOI: 10.1097/ICO.0b013e31823f8ce4     Document Type: Article
Times cited : (18)

References (18)
  • 1
    • 0034752947 scopus 로고    scopus 로고
    • Clinical comparison of ocular blood flow tonometer Tonopen and Goldmann applanation tonometer for measuring intraocular pressure in postkeratoplasty eyes
    • Rao VJ, Gnanaraj L, Mitchell KW, et al. Clinical comparison of ocular blood flow tonometer, Tonopen, and Goldmann applanation tonometer for measuring intraocular pressure in postkeratoplasty eyes. Cornea. 2001;20:834-838.
    • (2001) Cornea , vol.20 , pp. 834-838
    • Rao, V.J.1    Gnanaraj, L.2    Mitchell, K.W.3
  • 2
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    • Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005;31: 156-162.
    • (2005) J. Cataract. Refract. Surg. , vol.31 , pp. 156-162
    • Luce, D.A.1
  • 3
    • 34547105084 scopus 로고    scopus 로고
    • Corneal biomechanical properties in normal, post-Laser in situ keratomileusis, and keratoconic eyes
    • Ortiz D, Piñero D, Shabayek MH, et al. Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes. J Cataract Refract Surg. 2007;33:1371-1375.
    • (2007) J. Cataract. Refract. Surg. , vol.33 , pp. 1371-1375
    • Ortiz, D.1    Piñero, D.2    Shabayek, M.H.3
  • 4
    • 33750995542 scopus 로고    scopus 로고
    • The use of the Reichert ocular response analyser to establish the relationship between ocular hysteresis, corneal resistance factor and central corneal thickness in normal eyes
    • Shah S, Laiquzzaman M, Cunliffe I, et al. The use of the Reichert ocular response analyser to establish the relationship between ocular hysteresis, corneal resistance factor and central corneal thickness in normal eyes. Cont Lens Anterior Eye. 2006;29:257-262.
    • (2006) Cont. Lens Anterior Eye , vol.29 , pp. 257-262
    • Shah, S.1    Laiquzzaman, M.2    Cunliffe, I.3
  • 5
    • 46949110019 scopus 로고    scopus 로고
    • Corneal hysteresis and cornealresistance factor in keratoectasia: findings using the Reichert ocular response analyzer
    • Kirwan C, O'Malley D, O'Keefe M. Corneal hysteresis and cornealresistance factor in keratoectasia: findings using the Reichert ocular response analyzer. Ophthalmologica. 2008;222:334-337.
    • (2008) Ophthalmologica , vol.222 , pp. 334-337
    • Kirwan, C.1    O'Malley, D.2    O'Keefe, M.3
  • 6
    • 34548022426 scopus 로고    scopus 로고
    • Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes
    • Shah S, Laiquzzaman M, Bhojwani R, et al. Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes. Invest Ophthalmol Vis Sci. 2007;48: 3026-3031.
    • (2007) Invest. Ophthalmol. Vis. Sci. , vol.48 , pp. 3026-3031
    • Shah, S.1    Laiquzzaman, M.2    Bhojwani, R.3
  • 8
    • 51649083685 scopus 로고    scopus 로고
    • Biomechanical properties of the cornea in high myopia
    • Shen M, Fan F, Xue A, et al. Biomechanical properties of the cornea in high myopia. Vision Res. 2008;48:2167-2171.
    • (2008) Vision Res. , vol.48 , pp. 2167-2171
    • Shen, M.1    Fan, F.2    Xue, A.3
  • 9
    • 28044466002 scopus 로고    scopus 로고
    • Outcomes of penetrating keratoplasty in keratoconus
    • Javadi MA, Motlagh BF, Jafarinasab MR, et al. Outcomes of penetrating keratoplasty in keratoconus. Cornea. 2005;24:941-946.
    • (2005) Cornea , vol.24 , pp. 941-946
    • Javadi, M.A.1    Motlagh, B.F.2    Jafarinasab, M.R.3
  • 10
    • 78149283908 scopus 로고    scopus 로고
    • Changes in corneal biomechanics in patients with keratoconus after penetrating keratoplasty
    • Yenerel NM, Kucumen RB, Gorgun E. Changes in corneal biomechanics in patients with keratoconus after penetrating keratoplasty. Cornea. 2010; 29:1247-1251.
    • (2010) Cornea , vol.29 , pp. 1247-1251
    • Yenerel, N.M.1    Kucumen, R.B.2    Gorgun, E.3
  • 11
    • 77957299750 scopus 로고    scopus 로고
    • Evaluation of corneal biomechanical properties following penetrating keratoplasty using the ocular response analyzer
    • Shin JY, Choi JS, Oh JY, et al. Evaluation of corneal biomechanical properties following penetrating keratoplasty using the ocular response analyzer. Korean J Ophthalmol. 2010;24:139-142.
    • (2010) Korean J. Ophthalmol. , vol.24 , pp. 139-142
    • Shin, J.Y.1    Choi, J.S.2    Oh, J.Y.3
  • 12
    • 0042563088 scopus 로고    scopus 로고
    • Risk factors for various causes of failure in initial corneal grafts
    • Price MO, Thompson RW Jr, Price FW Jr. Risk factors for various causes of failure in initial corneal grafts. Arch Ophthalmol. 2003;121: 1087-1092.
    • (2003) Arch. Ophthalmol. , vol.121 , pp. 1087-1092
    • Price, M.O.1    Thompson Jr., R.W.2    Price Jr., F.W.3
  • 13
    • 77649098245 scopus 로고    scopus 로고
    • Large-diameter penetrating keratoplasty: Indications and outcomes
    • Skeens HM, Holland EJ. Large-diameter penetrating keratoplasty: Indications and outcomes. Cornea. 2010;29:296-301.
    • (2010) Cornea , vol.29 , pp. 296-301
    • Skeens, H.M.1    Holland, E.J.2
  • 14
    • 1542407177 scopus 로고    scopus 로고
    • Late onset post-keratoplasty astigmatism in patients with keratoconus
    • Lim L, Pesudovs K, Goggin M, et al. Late onset post-keratoplasty astigmatism in patients with keratoconus. Br J Ophthalmol. 2004;88: 371-376.
    • (2004) Br. J. Ophthalmol. , vol.88 , pp. 371-376
    • Lim, L.1    Pesudovs, K.2    Goggin, M.3
  • 15
    • 2142647887 scopus 로고    scopus 로고
    • Same-size donor corneas for myopic keratoconus
    • Shimmura S, Ando M, Ishioka M, et al. Same-size donor corneas for myopic keratoconus. Cornea. 2004;23:345-349.
    • (2004) Cornea , vol.23 , pp. 345-349
    • Shimmura, S.1    Ando, M.2    Ishioka, M.3
  • 16
    • 0032994224 scopus 로고    scopus 로고
    • Tono-Pen tonometer and corneal thickness
    • (pt 1)
    • Mok KH, Wong CS, Lee VW. Tono-Pen tonometer and corneal thickness. Eye (Lond). 1999;13(pt 1):35-37.
    • (1999) Eye (Lond.) , vol.13 , pp. 35-37
    • Mok, K.H.1    Wong, C.S.2    Lee, V.W.3
  • 17
    • 38349084770 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry and Goldmann applanation tonometry in deep lamellar and penetrating keratoplasties
    • Ceruti P, Morbio R, Marraffa M, et al. Comparison of dynamic contour tonometry and Goldmann applanation tonometry in deep lamellar and penetrating keratoplasties. Am J Ophthalmol. 2008;145:215-221.
    • (2008) Am. J. Ophthalmol. , vol.145 , pp. 215-221
    • Ceruti, P.1    Morbio, R.2    Marraffa, M.3
  • 18
    • 33748790161 scopus 로고    scopus 로고
    • Evaluation of dynamic contour tonometry in penetrating keratoplasties [in German]
    • Viestenz A, Langenbucher A, Seitz B, et al. Evaluation of dynamic contour tonometry in penetrating keratoplasties [in German]. Ophthalmologe. 2006;103:773-776.
    • (2006) Ophthalmologe , vol.103 , pp. 773-776
    • Viestenz, A.1    Langenbucher, A.2    Seitz, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.