-
1
-
-
0027291601
-
Sources of error with use of Goldmann-type tonometers
-
Whitacre MM, Stein R. Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol. 1993;38:1-30.
-
(1993)
Surv Ophthalmol
, vol.38
, pp. 1-30
-
-
Whitacre, M.M.1
Stein, R.2
-
2
-
-
0035989307
-
Changes in intraocular pressure after laser in situ keratomileusis for myopia, hyperopia, and astigmatism
-
Agudelo LM, Molina CA, Alvarez DL. Changes in intraocular pressure after laser in situ keratomileusis for myopia, hyperopia, and astigmatism. J Refract Surg. 2002;18:472-474.
-
(2002)
J Refract Surg
, vol.18
, pp. 472-474
-
-
Agudelo, L.M.1
Molina, C.A.2
Alvarez, D.L.3
-
3
-
-
0033642305
-
The correlation between IOP measurement, central corneal thickness and corneal curvature
-
Burvenich H, Sallet G, De Clercq J. The correlation between IOP measurement, central corneal thickness and corneal curvature. Bull Soc Belge Ophtalmol. 2000;276:23-26.
-
(2000)
Bull Soc Belge Ophtalmol
, vol.276
, pp. 23-26
-
-
Burvenich, H.1
Sallet, G.2
De Clercq, J.3
-
4
-
-
0030897864
-
Reduction in intraocular pressure after excimer laser photorefractive keratectomy. Correlation with pretreatment myopia
-
Chatterjee A, Shah S, Bessant DA, et al. Reduction in intraocular pressure after excimer laser photorefractive keratectomy. Correlation with pretreatment myopia. Ophthalmology. 1997;104:355-359.
-
(1997)
Ophthalmology
, vol.104
, pp. 355-359
-
-
Chatterjee, A.1
Shah, S.2
Bessant, D.A.3
-
5
-
-
0034874717
-
Tonometry after laser in situ keratomileusis treatment
-
Duch S, Serra A, Castanera J, et al. Tonometry after laser in situ keratomileusis treatment. J Glaucoma. 2001;10:261-265.
-
(2001)
J Glaucoma
, vol.10
, pp. 261-265
-
-
Duch, S.1
Serra, A.2
Castanera, J.3
-
6
-
-
0035078293
-
Change in intraocular pressure in myopic eyes measured with contact and non-contact tonometers after laser in situ keratomileusis
-
El Danasoury MA, El Maghraby A, Coorpender SJ. Change in intraocular pressure in myopic eyes measured with contact and non-contact tonometers after laser in situ keratomileusis. J Refract Surg. 2001;17:97-104.
-
(2001)
J Refract Surg
, vol.17
, pp. 97-104
-
-
El Danasoury, M.A.1
El Maghraby, A.2
Coorpender, S.J.3
-
7
-
-
0031668042
-
Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis
-
Emara B, Probst LE, Tingey DP, et al. Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis. J Cataract Refract Surg. 1998;24:1320-1325.
-
(1998)
J Cataract Refract Surg
, vol.24
, pp. 1320-1325
-
-
Emara, B.1
Probst, L.E.2
Tingey, D.P.3
-
9
-
-
0031812629
-
Intraocular pressure change measured by Goldmann tonometry after laser in situ keratomileusis
-
Fournier AV, Podtetenev M, Lemire J, et al. Intraocular pressure change measured by Goldmann tonometry after laser in situ keratomileusis. J Cataract Refract Surg. 1998;24:905-910.
-
(1998)
J Cataract Refract Surg
, vol.24
, pp. 905-910
-
-
Fournier, A.V.1
Podtetenev, M.2
Lemire, J.3
-
10
-
-
0035163532
-
Intraocular pressure and photorefractive keratectomy: A comparison of three different tonometers
-
Garzozi HJ, Chung HS, Lang Y, et al. Intraocular pressure and photorefractive keratectomy: a comparison of three different tonometers. Cornea. 2001;20:33-36.
-
(2001)
Cornea
, vol.20
, pp. 33-36
-
-
Garzozi, H.J.1
Chung, H.S.2
Lang, Y.3
-
11
-
-
0035070611
-
Intraocular pressure after excimer laser myopic refractive surgery
-
Montes-Mico R, Charman WN. Intraocular pressure after excimer laser myopic refractive surgery. Ophthalmic Physiol Opt. 2001;21:228-235.
-
(2001)
Ophthalmic Physiol Opt
, vol.21
, pp. 228-235
-
-
Montes-Mico, R.1
Charman, W.N.2
-
12
-
-
0034886296
-
Changes in measured intraocular pressure after hyperopic photorefractive keratectomy
-
Munger R, Dohadwala AA, Hodge WG, et al. Changes in measured intraocular pressure after hyperopic photorefractive keratectomy. J Cataract Refract Surg. 2001;27:1254-1262.
-
(2001)
J Cataract Refract Surg
, vol.27
, pp. 1254-1262
-
-
Munger, R.1
Dohadwala, A.A.2
Hodge, W.G.3
-
13
-
-
0034893227
-
Grossly false applanation tonometry associated with interface fluid in susceptible LASIK patients
-
Parekh JG, Raviv T, Speaker MG. Grossly false applanation tonometry associated with interface fluid in susceptible LASIK patients [letter]. J Cataract Refract Surg. 2001;27:1143-1144.
-
(2001)
J Cataract Refract Surg
, vol.27
, pp. 1143-1144
-
-
Parekh, J.G.1
Raviv, T.2
Speaker, M.G.3
-
14
-
-
0035120736
-
Reduction in intraocular pressure after laser in situ keratomileusis
-
Park HJ, Uhm KB, Hong C. Reduction in intraocular pressure after laser in situ keratomileusis. J Cataract Refract Surg. 2001;27:303-309.
-
(2001)
J Cataract Refract Surg
, vol.27
, pp. 303-309
-
-
Park, H.J.1
Uhm, K.B.2
Hong, C.3
-
15
-
-
0032974923
-
Effects of central corneal thickness on measurement of intra-ocular pressure in keratoconus and post-keratoplasty
-
Patel S, McLaughlin JM. Effects of central corneal thickness on measurement of intra-ocular pressure in keratoconus and post-keratoplasty. Ophthalmic Physiol Opt. 1999;19:236-241.
-
(1999)
Ophthalmic Physiol Opt
, vol.19
, pp. 236-241
-
-
Patel, S.1
McLaughlin, J.M.2
-
16
-
-
0034953996
-
Changes in intraocular pressure after laser in situ keratomileusis
-
Rashad KM, Bahnassy AA. Changes in intraocular pressure after laser in situ keratomileusis. J Refract Surg. 2001;17:420-427.
-
(2001)
J Refract Surg
, vol.17
, pp. 420-427
-
-
Rashad, K.M.1
Bahnassy, A.A.2
-
17
-
-
0033780230
-
Correlation between intraocular pressure and corneal stromal thickness after laser in situ keratomileusis
-
Recep OF, Cagil N, Hasiripi H. Correlation between intraocular pressure and corneal stromal thickness after laser in situ keratomileusis. J Cataract Refract Surg. 2000;26:1480-1483.
-
(2000)
J Cataract Refract Surg
, vol.26
, pp. 1480-1483
-
-
Recep, O.F.1
Cagil, N.2
Hasiripi, H.3
-
18
-
-
0034536610
-
Paradoxical hypotony after laser in situ keratomileusis
-
Rehany U, Bersudsky V, Rumelt S. Paradoxical hypotony after laser in situ keratomileusis. J Catract Refract Surg. 2000;26:1823-1826.
-
(2000)
J Catract Refract Surg
, vol.26
, pp. 1823-1826
-
-
Rehany, U.1
Bersudsky, V.2
Rumelt, S.3
-
19
-
-
0028864226
-
Intraocular pressure after excimer laser photorefractive keratectomy for myopia
-
Schipper I, Senn P, Thomann U, et al. Intraocular pressure after excimer laser photorefractive keratectomy for myopia. J Refract Surg. 1995;11:366-370.
-
(1995)
J Refract Surg
, vol.11
, pp. 366-370
-
-
Schipper, I.1
Senn, P.2
Thomann, U.3
-
20
-
-
0032836524
-
Pneumotonometry versus Goldmann tonometry after laser in situ keratomileusis for myopia
-
Zadok D, Tran DB, Twa M, et al. Pneumotonometry versus Goldmann tonometry after laser in situ keratomileusis for myopia. J Cataract Refract Surg. 1999;25:1344-1348.
-
(1999)
J Cataract Refract Surg
, vol.25
, pp. 1344-1348
-
-
Zadok, D.1
Tran, D.B.2
Twa, M.3
-
22
-
-
0033021344
-
Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo
-
Orssengo GJ, Pye DC. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull Mathematical Biol. 1999;61:551-572.
-
(1999)
Bull Mathematical Biol
, vol.61
, pp. 551-572
-
-
Orssengo, G.J.1
Pye, D.C.2
-
23
-
-
0029609715
-
Ocular hypertension and central corneal thickness
-
Argus WA. Ocular hypertension and central corneal thickness. Ophthalmology. 1995;102:1810-1812.
-
(1995)
Ophthalmology
, vol.102
, pp. 1810-1812
-
-
Argus, W.A.1
-
24
-
-
0032936567
-
Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma
-
Copt RP, Thomas R, Mermoud A. Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma. Arch Ophthalmol. 1999;117:14-16.
-
(1999)
Arch Ophthalmol
, vol.117
, pp. 14-16
-
-
Copt, R.P.1
Thomas, R.2
Mermoud, A.3
-
25
-
-
0030885993
-
Central corneal thickness in normal, glaucomatous, and ocular hypertensive eyes
-
Herndon LW, Choudhri SA, Cox T, et al. Central corneal thickness in normal, glaucomatous, and ocular hypertensive eyes. Arch Ophthalmol. 1997;115:1137-1141.
-
(1997)
Arch Ophthalmol
, vol.115
, pp. 1137-1141
-
-
Herndon, L.W.1
Choudhri, S.A.2
Cox, T.3
-
26
-
-
0031848594
-
Applanation tonometry and correction according to corneal thickness
-
Stodtmeister R. Applanation tonometry and correction according to corneal thickness. Acta Ophthalmol Scand. 1998;76:319-324.
-
(1998)
Acta Ophthalmol Scand
, vol.76
, pp. 319-324
-
-
Stodtmeister, R.1
-
27
-
-
0242288026
-
Repeatability and reproducibility of the BV1 ultrasonic pachymeter
-
Gunvant P, Broadway DC, Watkins RJ. Repeatability and reproducibility of the BV1 ultrasonic pachymeter. Eye. 2003;17:825-828.
-
(2003)
Eye
, vol.17
, pp. 825-828
-
-
Gunvant, P.1
Broadway, D.C.2
Watkins, R.J.3
-
28
-
-
0036235038
-
Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen
-
Bhan A, Browning AC, Shah S, et al. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen. Invest Ophthalmol Vis Sci. 2002;43:1389-1392.
-
(2002)
Invest Ophthalmol Vis Sci
, vol.43
, pp. 1389-1392
-
-
Bhan, A.1
Browning, A.C.2
Shah, S.3
-
29
-
-
0034971648
-
Central corneal thickness, tonometry, and ocular dimensions in glaucoma and ocular hypertension
-
Singh RP, Goldberg I, Graham SL, et al. Central corneal thickness, tonometry, and ocular dimensions in glaucoma and ocular hypertension. J Glaucoma. 2001;10:206-210.
-
(2001)
J Glaucoma
, vol.10
, pp. 206-210
-
-
Singh, R.P.1
Goldberg, I.2
Graham, S.L.3
-
30
-
-
0030963090
-
Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study
-
Wolfs RC, Klaver CC, Vingerling JR, et al. Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study. Am J Ophthalmol. 1997;123:767-772.
-
(1997)
Am J Ophthalmol
, vol.123
, pp. 767-772
-
-
Wolfs, R.C.1
Klaver, C.C.2
Vingerling, J.R.3
-
32
-
-
1842452811
-
Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer
-
Gunvant P, Baskaran M, Vijaya L, et al. Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer. Br J Ophthalmol. 2004;88:518-522.
-
(2004)
Br J Ophthalmol
, vol.88
, pp. 518-522
-
-
Gunvant, P.1
Baskaran, M.2
Vijaya, L.3
-
33
-
-
0031807443
-
Central corneal thickness and intraocular pressure in a Mongolian population
-
Foster PJ, Baasanhu J, Alsbirk PH, et al. Central corneal thickness and intraocular pressure in a Mongolian population. Ophthalmology. 1998;105:969-973.
-
(1998)
Ophthalmology
, vol.105
, pp. 969-973
-
-
Foster, P.J.1
Baasanhu, J.2
Alsbirk, P.H.3
-
34
-
-
0033498048
-
Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic
-
Shah S, Chatterjee A, Mathai M, et al. Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic. Ophthalmology. 1999;106:2154-2160.
-
(1999)
Ophthalmology
, vol.106
, pp. 2154-2160
-
-
Shah, S.1
Chatterjee, A.2
Mathai, M.3
-
35
-
-
0034203035
-
The role of central corneal thickness in the diagnosis of glaucoma
-
Thomas R, Korah S, Muliyil J. The role of central corneal thickness in the diagnosis of glaucoma. Indian J Ophthalmol. 2000;48:107-111.
-
(2000)
Indian J Ophthalmol
, vol.48
, pp. 107-111
-
-
Thomas, R.1
Korah, S.2
Muliyil, J.3
-
36
-
-
0035163029
-
Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings
-
Feltgen N, Leifert D, Funk J. Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings. Br J Ophthalmol. 2001;85:85-87.
-
(2001)
Br J Ophthalmol
, vol.85
, pp. 85-87
-
-
Feltgen, N.1
Leifert, D.2
Funk, J.3
-
37
-
-
0016261804
-
Central corneal thickness in low-tension glaucoma
-
Ehlers N, Hansen FK. Central corneal thickness in low-tension glaucoma. Acta Ophthalmol. 1974;52:740-746.
-
(1974)
Acta Ophthalmol
, vol.52
, pp. 740-746
-
-
Ehlers, N.1
Hansen, F.K.2
-
38
-
-
0031703801
-
Tonometry in adults and children. A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo
-
Eisenberg DL, Sherman BG, McKeown CA, et al. Tonometry in adults and children. A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo. Ophthalmology. 1998;105:1173-1181.
-
(1998)
Ophthalmology
, vol.105
, pp. 1173-1181
-
-
Eisenberg, D.L.1
Sherman, B.G.2
McKeown, C.A.3
-
39
-
-
0017840770
-
Increased corneal thickness simulating elevated intraocular pressure
-
Johnson M, Kass MA, Moses RA, et al. Increased corneal thickness simulating elevated intraocular pressure. Arch Ophthalmol. 1978;96:664-665.
-
(1978)
Arch Ophthalmol
, vol.96
, pp. 664-665
-
-
Johnson, M.1
Kass, M.A.2
Moses, R.A.3
-
40
-
-
0027269723
-
The effect of corneal thickness on applanation tonometry
-
Whitacre MM, Stein RA, Hassanein K. The effect of corneal thickness on applanation tonometry. Am J Ophthalmol. 1993;115:592-596.
-
(1993)
Am J Ophthalmol
, vol.115
, pp. 592-596
-
-
Whitacre, M.M.1
Stein, R.A.2
Hassanein, K.3
-
41
-
-
0036149032
-
IOP measurement and central corneal thickness
-
Stodtmeister R, Kron M, Gaus W. IOP measurement and central corneal thickness. Br J Ophthalmol. 2002;86:120-121.
-
(2002)
Br J Ophthalmol
, vol.86
, pp. 120-121
-
-
Stodtmeister, R.1
Kron, M.2
Gaus, W.3
-
42
-
-
85069115398
-
IOP measurements and central corneal thickness
-
Feltgen N, Funk J. IOP measurements and central corneal thickness [authors reply]. Br J Ophthalmol. 2002;86:121.
-
(2002)
Br J Ophthalmol
, vol.86
, pp. 121
-
-
Feltgen, N.1
Funk, J.2
-
43
-
-
0015878930
-
Corneal curvature in applanation tonometry
-
Mark HH. Corneal curvature in applanation tonometry. Am J Ophthalmol. 1973;76:223-224.
-
(1973)
Am J Ophthalmol
, vol.76
, pp. 223-224
-
-
Mark, H.H.1
|