메뉴 건너뛰기




Volumn 31, Issue 1, 2005, Pages 146-155

Influence of corneal biomechanical properties on intraocular pressure measurement: Quantitative analysis

Author keywords

[No Author keywords available]

Indexed keywords

ANALYTICAL ERROR; ARTICLE; BIOMECHANICS; CORNEA; CORNEA CURVATURE; CORNEA THICKNESS; INTRAOCULAR PRESSURE; MATHEMATICAL ANALYSIS; PREDICTION; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; SURFACE TENSION; TEAR FILM; TONOMETRY; YOUNG MODULUS;

EID: 13844313434     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2004.09.031     Document Type: Article
Times cited : (670)

References (48)
  • 1
  • 2
    • 0030897864 scopus 로고    scopus 로고
    • Reduction in intraocular pressure after excimer laser photorefractive keratectomy; Correlation with pretreatment myopia
    • A. Chatterjee, S. Shah, and D.A. Bessant Reduction in intraocular pressure after excimer laser photorefractive keratectomy; correlation with pretreatment myopia Ophthalmology 104 1997 355 359
    • (1997) Ophthalmology , vol.104 , pp. 355-359
    • Chatterjee, A.1    Shah, S.2    Bessant, D.A.3
  • 3
    • 0031812629 scopus 로고    scopus 로고
    • Intraocular pressure change measured by Goldmann tonometry after laser in situ keratomileusis
    • A.V. Fournier, M. Podtetenev, and J. Lemire Intraocular pressure change measured by Goldmann tonometry after laser in situ keratomileusis J Cataract Refract Surg 24 1998 905 910
    • (1998) J Cataract Refract Surg , vol.24 , pp. 905-910
    • Fournier, A.V.1    Podtetenev, M.2    Lemire, J.3
  • 5
    • 0033780230 scopus 로고    scopus 로고
    • Correlation between intraocular pressure and corneal stromal thickness after laser in situ keratomileusis
    • Ö.F. Recep, N. Çagil, and H. Hasiripi Correlation between intraocular pressure and corneal stromal thickness after laser in situ keratomileusis J Cataract Refract Surg 26 2000 1480 1483
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1480-1483
    • Recep, Ö.F.1    Çagil, N.2    Hasiripi, H.3
  • 6
    • 0035070611 scopus 로고    scopus 로고
    • Intraocular pressure after excimer laser myopic refractive surgery
    • R. Montés-Micó, and W.N. Charman Intraocular pressure after excimer laser myopic refractive surgery Ophthalmic Physiol Opt 21 2001 228 235
    • (2001) Ophthalmic Physiol Opt , vol.21 , pp. 228-235
    • Montés-Micó, R.1    Charman, W.N.2
  • 7
    • 0034886296 scopus 로고    scopus 로고
    • Changes in measured intraocular pressure after hyperopic photorefractive keratectomy
    • R. Munger, A.A. Dohadwala, and W.G. Hodge Changes in measured intraocular pressure after hyperopic photorefractive keratectomy J Cataract Refract Surg 27 2001 1254 1262
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1254-1262
    • Munger, R.1    Dohadwala, A.A.2    Hodge, W.G.3
  • 8
    • 0034874717 scopus 로고    scopus 로고
    • Tonometry after laser in situ keratomileusis treatment
    • S. Duch, A. Serra, and J. Castanera Tonometry after laser in situ keratomileusis treatment J Glaucoma 10 2001 261 265
    • (2001) J Glaucoma , vol.10 , pp. 261-265
    • Duch, S.1    Serra, A.2    Castanera, J.3
  • 9
    • 0034953996 scopus 로고    scopus 로고
    • Changes in intraocular pressure after laser in situ keratomileusis
    • K.M. Rashad, and A.A. Bahnassy Changes in intraocular pressure after laser in situ keratomileusis J Refract Surg 17 2001 420 427
    • (2001) J Refract Surg , vol.17 , pp. 420-427
    • Rashad, K.M.1    Bahnassy, A.A.2
  • 10
    • 0036183936 scopus 로고    scopus 로고
    • Assessment of applanation tonometry after hyperopic laser in situ keratomileusis
    • L. Alonso-Muñoz, A. Lleó-Pérez, M.S. Rahhal, and J.A. Sanchis-Gimeno Assessment of applanation tonometry after hyperopic laser in situ keratomileusis Cornea 21 2002 156 160
    • (2002) Cornea , vol.21 , pp. 156-160
    • Alonso-Muñoz, L.1    Lleó-Pérez, A.2    Rahhal, M.S.3    Sanchis-Gimeno, J.A.4
  • 11
    • 0037328758 scopus 로고    scopus 로고
    • Influence of corneal variables on accuracy of intraocular pressure measurement
    • K.F. Damji, R.H. Muni, and R.M. Munger Influence of corneal variables on accuracy of intraocular pressure measurement J Glaucoma 12 2003 69 80
    • (2003) J Glaucoma , vol.12 , pp. 69-80
    • Damji, K.F.1    Muni, R.H.2    Munger, R.M.3
  • 12
    • 13844318981 scopus 로고    scopus 로고
    • Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK
    • D.S. Siganos, G.I. Papastergiou, and C. Moedas Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK J Cataract Refract Surg 30 2004 746 751
    • (2004) J Cataract Refract Surg , vol.30 , pp. 746-751
    • Siganos, D.S.1    Papastergiou, G.I.2    Moedas, C.3
  • 13
    • 0016663381 scopus 로고
    • Applanation tonometry and central corneal thickness
    • N. Ehlers, T. Bramsen, and S. Sperling Applanation tonometry and central corneal thickness Acta Ophthalmol 53 1975 34 43
    • (1975) Acta Ophthalmol , vol.53 , pp. 34-43
    • Ehlers, N.1    Bramsen, T.2    Sperling, S.3
  • 14
    • 0027269723 scopus 로고
    • The effect of corneal thickness on applanation tonometry
    • M.M. Whitacre, R.A. Stein, and K. Hassanein The effect of corneal thickness on applanation tonometry Am J Ophthalmol 115 1993 592 596
    • (1993) Am J Ophthalmol , vol.115 , pp. 592-596
    • Whitacre, M.M.1    Stein, R.A.2    Hassanein, K.3
  • 15
    • 0029609715 scopus 로고
    • Ocular hypertension and central corneal thickness
    • W.A. Argus Ocular hypertension and central corneal thickness Ophthalmology 102 1995 1810 1812
    • (1995) Ophthalmology , vol.102 , pp. 1810-1812
    • Argus, W.A.1
  • 16
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • M.J. Doughty, and M.L. Zaman Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach Surv Ophthalmol 44 2000 367 408
    • (2000) Surv Ophthalmol , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 17
    • 0027291601 scopus 로고
    • Sources of error with use of Goldmann-type tonometers
    • M.M. Whitacre, and R. Stein Sources of error with use of Goldmann-type tonometers Surv Ophthalmol 38 1993 1 30
    • (1993) Surv Ophthalmol , vol.38 , pp. 1-30
    • Whitacre, M.M.1    Stein, R.2
  • 18
    • 0023923482 scopus 로고
    • Corneal elasticity and ocular rigidity in normal and keratoconic eyes
    • C. Edmund Corneal elasticity and ocular rigidity in normal and keratoconic eyes Acta Ophthalmol 66 1988 134 140
    • (1988) Acta Ophthalmol , vol.66 , pp. 134-140
    • Edmund, C.1
  • 19
    • 0028200939 scopus 로고
    • Holographic interferometry of intact and radially incised human eye-bank corneas
    • M.K. Smolek Holographic interferometry of intact and radially incised human eye-bank corneas J Cataract Refract Surg 20 1994 277 286
    • (1994) J Cataract Refract Surg , vol.20 , pp. 277-286
    • Smolek, M.K.1
  • 20
    • 0030199985 scopus 로고    scopus 로고
    • Regional elastic performance of the human cornea
    • J.Ø. Hjortdal Regional elastic performance of the human cornea J Biomech 29 1996 931 942
    • (1996) J Biomech , vol.29 , pp. 931-942
    • Hjortdal J.Ø1
  • 21
    • 0025737488 scopus 로고
    • Quantitative study of collagen and elastin of the optic nerve head and sclera in human and experimental monkey glaucoma
    • H.A. Quigley, M.E. Dorman-Pease, and A.E. Brown Quantitative study of collagen and elastin of the optic nerve head and sclera in human and experimental monkey glaucoma Curr Eye Res 10 1991 877 888
    • (1991) Curr Eye Res , vol.10 , pp. 877-888
    • Quigley, H.A.1    Dorman-Pease, M.E.2    Brown, A.E.3
  • 23
    • 0344121541 scopus 로고
    • Little, Brown and Company Boston, MA
    • J. Gloster Tonometry and Tonography 1965 Little, Brown and Company Boston, MA (Int Ophthalmol Clin 1965; vol 5, no 4)
    • (1965) Tonometry and Tonography
    • Gloster, J.1
  • 24
    • 0035144705 scopus 로고    scopus 로고
    • Central corneal thickness of Caucasians and African Americans in glaucomatous and nonglaucomatous populations
    • F.A. La Rosa, R.L. Gross, and S. Orengo-Nania Central corneal thickness of Caucasians and African Americans in glaucomatous and nonglaucomatous populations Arch Ophthalmol 119 2001 23 27
    • (2001) Arch Ophthalmol , vol.119 , pp. 23-27
    • La Rosa, F.A.1    Gross, R.L.2    Orengo-Nania, S.3
  • 25
    • 51249188445 scopus 로고
    • A theoretical and experimental study of the mechanical behavior of the cornea with application to the measurement of the intraocular pressure
    • N.J. Shawartz, R.S. Mackay, and J.L. Sackman A theoretical and experimental study of the mechanical behavior of the cornea with application to the measurement of the intraocular pressure Bull Math Biophys 28 1966 585 643
    • (1966) Bull Math Biophys , vol.28 , pp. 585-643
    • Shawartz, N.J.1    MacKay, R.S.2    Sackman, J.L.3
  • 26
    • 0022929770 scopus 로고
    • The mechanical properties of rabbit and human cornea
    • B. Jue, and D.M. Maurice The mechanical properties of rabbit and human cornea J Biomech 19 1986 847 853
    • (1986) J Biomech , vol.19 , pp. 847-853
    • Jue, B.1    Maurice, D.M.2
  • 27
    • 0026748686 scopus 로고
    • Strip extensiometry for comparison of the mechanical response of bovine, rabbit, and human corneas
    • D.A. Hoeltzel, P. Altman, K. Buzard, and K. Choe Strip extensiometry for comparison of the mechanical response of bovine, rabbit, and human corneas J Biomech Eng 114 1992 202 215
    • (1992) J Biomech Eng , vol.114 , pp. 202-215
    • Hoeltzel, D.A.1    Altman, P.2    Buzard, K.3    Choe, K.4
  • 28
    • 0030972723 scopus 로고    scopus 로고
    • The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonometer
    • P.G. Mardelli, L.W. Piebenga, M.M. Whitacre, and K.D. Sigmund The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonometer Ophthalmology 104 1997 945 948 discussion by WA Argus, 949
    • (1997) Ophthalmology , vol.104 , pp. 945-948
    • Mardelli, P.G.1    Piebenga, L.W.2    Whitacre, M.M.3    Sigmund, K.D.4
  • 29
    • 0030226992 scopus 로고    scopus 로고
    • Main causes of reduced intraocular pressure after excimer laser photorefractive keratectomy
    • S. Patel, and I.M. Aslanides Main causes of reduced intraocular pressure after excimer laser photorefractive keratectomy [letter] J Refract Surg 12 1996 673
    • (1996) J Refract Surg , vol.12 , pp. 673
    • Patel, S.1    Aslanides, I.M.2
  • 30
    • 0036744718 scopus 로고    scopus 로고
    • Biomechanics of the cornea and wavefront-guided laser refractive surgery
    • C. Roberts Biomechanics of the cornea and wavefront-guided laser refractive surgery J Refract Surg 18 2002 S589 S592
    • (2002) J Refract Surg , vol.18
    • Roberts, C.1
  • 31
    • 0014331704 scopus 로고
    • A theoretical model of the cornea for use in studies of tonometry
    • C.C. Mow A theoretical model of the cornea for use in studies of tonometry Bull Math Biophys 30 1968 437 453
    • (1968) Bull Math Biophys , vol.30 , pp. 437-453
    • Mow, C.C.1
  • 33
    • 0014447794 scopus 로고
    • Position and curvature of the corneal apex
    • R.B. Mandell, and R. St Helen Position and curvature of the corneal apex Am J Optom 46 1969 25 29
    • (1969) Am J Optom , vol.46 , pp. 25-29
    • Mandell, R.B.1    St Helen, R.2
  • 34
    • 84950609221 scopus 로고
    • The mean shape of the human cornea
    • P.M. Kiely, G. Smith, and L.G. Carney The mean shape of the human cornea Optica Acta 29 1982 1027 1040
    • (1982) Optica Acta , vol.29 , pp. 1027-1040
    • Kiely, P.M.1    Smith, G.2    Carney, L.G.3
  • 35
    • 0033021344 scopus 로고    scopus 로고
    • Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo
    • G.J. Orssengo, and D.C. Pye Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo Bull Math Biol 61 1999 551 572
    • (1999) Bull Math Biol , vol.61 , pp. 551-572
    • Orssengo, G.J.1    Pye, D.C.2
  • 36
    • 0036272299 scopus 로고    scopus 로고
    • The Ocular Hypertension Treatment Study; Baseline factors that predict the onset of primary open-angle glaucoma; The Ocular Hypertension Treatment Study Group
    • M.O. Gordon, J.A. Beiser, and J.D. Brandt The Ocular Hypertension Treatment Study; Baseline factors that predict the onset of primary open-angle glaucoma; the Ocular Hypertension Treatment Study Group Arch Ophthalmol 120 2002 714 720
    • (2002) Arch Ophthalmol , vol.120 , pp. 714-720
    • Gordon, M.O.1    Beiser, J.A.2    Brandt, J.D.3
  • 37
    • 0003108832 scopus 로고    scopus 로고
    • Corneal biomechanics and their role in corneal ablative procedures
    • S.M. MacRae R.R. Krueger R.A. Applegate Slack Thorofare, NJ
    • C. Roberts, and W.J. Dupps Corneal biomechanics and their role in corneal ablative procedures S.M. MacRae R.R. Krueger R.A. Applegate Customized Corneal Ablation; the Quest for SuperVision 2001 Slack Thorofare, NJ 109 131
    • (2001) Customized Corneal Ablation; the Quest for SuperVision , pp. 109-131
    • Roberts, C.1    Dupps, W.J.2
  • 39
    • 0032619353 scopus 로고    scopus 로고
    • Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
    • J. Ophir, S.K. Alam, and B. Garra Elastography: ultrasonic estimation and imaging of the elastic properties of tissues Proc Inst Mech Eng [H] 213 1999 203 233
    • (1999) Proc Inst Mech Eng [H] , vol.213 , pp. 203-233
    • Ophir, J.1    Alam, S.K.2    Garra, B.3
  • 40
    • 0032411652 scopus 로고    scopus 로고
    • Elastic moduli of breast and prostate tissues under compression
    • T.A. Krouskop, T.M. Wheeler, and F. Kallel Elastic moduli of breast and prostate tissues under compression Ultrason Imaging 20 1998 260 274
    • (1998) Ultrason Imaging , vol.20 , pp. 260-274
    • Krouskop, T.A.1    Wheeler, T.M.2    Kallel, F.3
  • 42
    • 0034434740 scopus 로고    scopus 로고
    • A new constitutive framework for arterial wall mechanics and a comparative study of material models
    • G.A. Holzapfel, T.C. Gasser, and R.W. Ogden A new constitutive framework for arterial wall mechanics and a comparative study of material models J Elasticity 61 2000 1 48
    • (2000) J Elasticity , vol.61 , pp. 1-48
    • Holzapfel, G.A.1    Gasser, T.C.2    Ogden, R.W.3
  • 43
    • 0029098770 scopus 로고
    • Dynamic viscoelastic nonlinearity of lung parenchymal tissue
    • D. Navajas, G.N. Maksym, and J.H.T. Bates Dynamic viscoelastic nonlinearity of lung parenchymal tissue J Appl Physiol 79 1995 348 356
    • (1995) J Appl Physiol , vol.79 , pp. 348-356
    • Navajas, D.1    Maksym, G.N.2    Bates, J.H.T.3
  • 44
    • 0029056163 scopus 로고
    • A method for the evaluation of tensile properties of skin equivalents
    • H. Lafrance, M. Guillot, L. Germain, and F.A. Auger A method for the evaluation of tensile properties of skin equivalents Med Eng Phys 17 1995 537 543
    • (1995) Med Eng Phys , vol.17 , pp. 537-543
    • Lafrance, H.1    Guillot, M.2    Germain, L.3    Auger, F.A.4
  • 45
    • 0037269293 scopus 로고    scopus 로고
    • Holographic interferometry of excimer-laser-ablated bovine eyes: First results
    • W. Förster, T. Stupp, and H. Kasprzak Holographic interferometry of excimer-laser-ablated bovine eyes: first results Ophthalmologica 217 2003 62 67
    • (2003) Ophthalmologica , vol.217 , pp. 62-67
    • Förster, W.1    Stupp, T.2    Kasprzak, H.3
  • 46
    • 0028200939 scopus 로고
    • Holographic interferometry of intact and radially incised human eye-bank corneas
    • M.K. Smolek Holographic interferometry of intact and radially incised human eye-bank corneas J Cataract Refract Surg 20 1994 277 286
    • (1994) J Cataract Refract Surg , vol.20 , pp. 277-286
    • Smolek, M.K.1
  • 47
    • 0030561003 scopus 로고    scopus 로고
    • An ultrasonic technique for the measurement of the elastic moduli of human cornea
    • H. Wang, P.L. Prendiville, P.J. McDonnell, and W.V. Chang An ultrasonic technique for the measurement of the elastic moduli of human cornea J Biomech 29 1996 1633 1636
    • (1996) J Biomech , vol.29 , pp. 1633-1636
    • Wang, H.1    Prendiville, P.L.2    McDonnell, P.J.3    Chang, W.V.4
  • 48
    • 0036132931 scopus 로고    scopus 로고
    • Strain imaging of corneal tissue with an ultrasound elasticity microscope
    • K.W. Hollman, S.Y. Emelianov, and J.H. Neiss Strain imaging of corneal tissue with an ultrasound elasticity microscope Cornea 21 2002 68 73
    • (2002) Cornea , vol.21 , pp. 68-73
    • Hollman, K.W.1    Emelianov, S.Y.2    Neiss, J.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.