메뉴 건너뛰기




Volumn 4, Issue 1, 2010, Pages 611-616

Measuring accurate IOPs: Does correction factor help or hurt?

Author keywords

Central corneal thickness; Dynamic contour tonometer; Goldmann applanation tonometer; Intraocular pressure; Tonometric correction factors

Indexed keywords


EID: 77956130873     PISSN: 11775467     EISSN: 11775483     Source Type: Book Series    
DOI: 10.2147/opth.s11105     Document Type: Article
Times cited : (10)

References (33)
  • 1
    • 0016663381 scopus 로고
    • Applanation tonometry and central corneal thickness
    • Ehlers N, Bramsen T, Sperling S. Applanation tonometry and central corneal thickness. Acta Ophthalmol (Copenh). 1975;53(1):34-43.
    • (1975) Acta Ophthalmol (Copenh) , vol.53 , Issue.1 , pp. 34-43
    • Ehlers, N.1    Bramsen, T.2    Sperling, S.3
  • 2
    • 34250803928 scopus 로고    scopus 로고
    • Dynamic contour tonometry (DCT) versus Goldmann applanation tonometry (GAT) - a comparison of agreement and reproducibility
    • Herdener S, Pache M, Lautebach S, Funk J. Dynamic contour tonometry (DCT) versus Goldmann applanation tonometry (GAT) - a comparison of agreement and reproducibility. Graefes Arch Clin Exp Ophthalmol. 2007;245(7):1027-1030.
    • (2007) Graefes Arch Clin Exp Ophthalmol , vol.245 , Issue.7 , pp. 1027-1030
    • Herdener, S.1    Pache, M.2    Lautebach, S.3    Funk, J.4
  • 3
    • 4344659799 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry with Goldmann applanation tonometry
    • Kaufmann C, Bachmann LM, Thiel MA. Comparison of dynamic contour tonometry with Goldmann applanation tonometry. Invest Ophthalmol Vis Sci. 2004;45(9):3118-3121.
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , Issue.9 , pp. 3118-3121
    • Kaufmann, C.1    Bachmann, L.M.2    Thiel, M.A.3
  • 4
    • 74549215576 scopus 로고    scopus 로고
    • Repeatability and reproducibility for intraocular pressure measurement by dynamic contour, ocular response analyzer, and Goldmann applanation tonometry
    • Sullivan-Mee M, Gerhardt G, Halverson KD, Qualls C. Repeatability and reproducibility for intraocular pressure measurement by dynamic contour, ocular response analyzer, and Goldmann applanation tonometry. J Glaucoma. 2009;18(9):666-673.
    • (2009) J Glaucoma , vol.18 , Issue.9 , pp. 666-673
    • Sullivan-Mee, M.1    Gerhardt, G.2    Halverson, K.D.3    Qualls, C.4
  • 5
    • 21344456718 scopus 로고    scopus 로고
    • A comparison of four methods of tonometry: Method agreement and interobserver variability
    • Tonnu PA, Ho T, Sharma K, White E, Bunce C, Garway-Heath D. A comparison of four methods of tonometry: method agreement and interobserver variability. Br J Ophthalmol. 2005;89(7):847-850.
    • (2005) Br J Ophthalmol , vol.89 , Issue.7 , pp. 847-850
    • Tonnu, P.A.1    Ho, T.2    Sharma, K.3    White, E.4    Bunce, C.5    Garway-Heath, D.6
  • 6
    • 33748983782 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry and Goldmann applanation tonometry in glaucoma patients and healthy subjects
    • Barleon L, Hoffmann EM, Berres M, Pfeiffer N, Grus FH. Comparison of dynamic contour tonometry and Goldmann applanation tonometry in glaucoma patients and healthy subjects. Am J Ophthalmol. 2006; 142(4):583-590.
    • (2006) Am J Ophthalmol , vol.142 , Issue.4 , pp. 583-590
    • Barleon, L.1    Hoffmann, E.M.2    Berres, M.3    Pfeiffer, N.4    Grus, F.H.5
  • 7
    • 33646120836 scopus 로고    scopus 로고
    • Dynamic contour tonometry (DCT) versus non-contact tonometry (NCT): A comparison study
    • Burvenich H, Burvenich E, Vincent C. Dynamic contour tonometry (DCT) versus non-contact tonometry (NCT): a comparison study. Bull Soc Belge Ophtalmol. 2005; (298):63-69.
    • (2005) Bull Soc Belge Ophtalmol , Issue.298 , pp. 63-69
    • Burvenich, H.1    Burvenich, E.2    Vincent, C.3
  • 8
    • 60149105326 scopus 로고    scopus 로고
    • Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes
    • Ceruti P, Morbio R, Marraffa M, Marchini G. Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes. Eye (Lond). 2009;23(2):262-269.
    • (2009) Eye (Lond) , vol.23 , Issue.2 , pp. 262-269
    • Ceruti, P.1    Morbio, R.2    Marraffa, M.3    Marchini, G.4
  • 9
    • 62549084669 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry and noncontact tonometry in ocular hypertension and glaucoma
    • Erdurmus M, Totan Y, Hepsen IF, Yagci R. Comparison of dynamic contour tonometry and noncontact tonometry in ocular hypertension and glaucoma. Eye (Lond). 2009;23(3):663-668.
    • (2009) Eye (Lond) , vol.23 , Issue.3 , pp. 663-668
    • Erdurmus, M.1    Totan, Y.2    Hepsen, I.F.3    Yagci, R.4
  • 10
    • 33845807890 scopus 로고    scopus 로고
    • Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonometry
    • Francis BA, Hsieh A, Lai MY, et al. Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonometry. Ophthalmology. 2007; 114(1):20-26.
    • (2007) Ophthalmology , vol.114 , Issue.1 , pp. 20-26
    • Francis, B.A.1    Hsieh, A.2    Lai, M.Y.3
  • 11
    • 67650660340 scopus 로고    scopus 로고
    • Influence of age, central corneal thickness, and quality score on dynamic contour tonometry
    • Jordao ML, Lupinacci AP, Ferreira EL, Enomoto IJ, Costa VP. Influence of age, central corneal thickness, and quality score on dynamic contour tonometry. Eye (Lond). 2009;23(6):1364-1369.
    • (2009) Eye (Lond) , vol.23 , Issue.6 , pp. 1364-1369
    • Jordao, M.L.1    Lupinacci, A.P.2    Ferreira, E.L.3    Enomoto, I.J.4    Costa, V.P.5
  • 12
    • 27744519845 scopus 로고    scopus 로고
    • Clinical comparison of contour and applanation tonometry and their relationship to pachymetry
    • Kniestedt C, Lin S, Choe J, Bostrom A, Nee M, Stamper RL. Clinical comparison of contour and applanation tonometry and their relationship to pachymetry. Arch Ophthalmol. 2005;123(11):1532-1537.
    • (2005) Arch Ophthalmol , vol.123 , Issue.11 , pp. 1532-1537
    • Kniestedt, C.1    Lin, S.2    Choe, J.3    Bostrom, A.4    Nee, M.5    Stamper, R.L.6
  • 13
    • 21344460937 scopus 로고    scopus 로고
    • The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry
    • Tonnu PA, Ho T, Newson T, et al. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol. 2005;89(7):851-854.
    • (2005) Br J Ophthalmol , vol.89 , Issue.7 , pp. 851-854
    • Tonnu, P.A.1    Ho, T.2    Newson, T.3
  • 15
    • 4444321895 scopus 로고    scopus 로고
    • Dynamic contour tonometry: A comparative study on human cadaver eyes
    • Kniestedt C, Nee M, Stamper RL. Dynamic contour tonometry: a comparative study on human cadaver eyes. Arch Ophthalmol. 2004;122(9): 1287-1293.
    • (2004) Arch Ophthalmol , vol.122 , Issue.9 , pp. 1287-1293
    • Kniestedt, C.1    Nee, M.2    Stamper, R.L.3
  • 16
    • 0034803965 scopus 로고    scopus 로고
    • Central corneal thickness in the Ocular hypertension treatment study (OHTS)
    • Brandt JD, Beiser JA, Kass MA, Gordon MO. Central corneal thickness in the Ocular hypertension treatment study (OHTS). Ophthalmology. 2001;108(10):1779-1788.
    • (2001) Ophthalmology , vol.108 , Issue.10 , pp. 1779-1788
    • Brandt, J.D.1    Beiser, J.A.2    Kass, M.A.3    Gordon, M.O.4
  • 17
    • 0035144705 scopus 로고    scopus 로고
    • Central corneal thickness of Caucasians and African Americans in glaucomatous and nonglaucomatous populations
    • La Rosa FA, Gross RL, Orengo-Nania S. Central corneal thickness of Caucasians and African Americans in glaucomatous and nonglaucomatous populations. Arch Ophthalmol. 2001;119(1):23-27.
    • (2001) Arch Ophthalmol , vol.119 , Issue.1 , pp. 23-27
    • la Rosa, F.A.1    Gross, R.L.2    Orengo-Nania, S.3
  • 18
    • 0141682012 scopus 로고    scopus 로고
    • Ross AJ, Moy A, Mostafavi R. Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics, and African Americans
    • Shimmyo M
    • Shimmyo M, Ross AJ, Moy A, Mostafavi R. Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics, and African Americans. Am J Ophthalmol. 2003;136(4):603-613.
    • (2003) Am J Ophthalmol , vol.136 , Issue.4 , pp. 603-613
  • 19
    • 0242288026 scopus 로고    scopus 로고
    • Repeatability and reproducibility of the BVI ultrasonic pachymeter
    • Gunvant P, Broadway DC, Watkins RJ. Repeatability and reproducibility of the BVI ultrasonic pachymeter. Eye (Lond). 2003;17(7):825-828.
    • (2003) Eye (Lond) , vol.17 , Issue.7 , pp. 825-828
    • Gunvant, P.1    Broadway, D.C.2    Watkins, R.J.3
  • 20
    • 0029609715 scopus 로고
    • Ocular hypertension and central corneal thickness
    • Argus WA. Ocular hypertension and central corneal thickness. Ophthalmology. 1995;102(12):1810-1812.
    • (1995) Ophthalmology , vol.102 , Issue.12 , pp. 1810-1812
    • Argus, W.A.1
  • 21
    • 0036235038 scopus 로고    scopus 로고
    • Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen
    • Bhan A, Browning AC, Shah S, Hamilton R, Dave D, Dua HS. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen. Invest Ophthalmol Vis Sci. 2002;43(5):1389-1392.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , Issue.5 , pp. 1389-1392
    • Bhan, A.1    Browning, A.C.2    Shah, S.3    Hamilton, R.4    Dave, D.5    Dua, H.S.6
  • 22
    • 0032936567 scopus 로고    scopus 로고
    • Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma
    • Copt RP, Thomas R, Mermoud A. Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma. Arch Ophthalmol. 1999;117(1):14-16.
    • (1999) Arch Ophthalmol , vol.117 , Issue.1 , pp. 14-16
    • Copt, R.P.1    Thomas, R.2    Mermoud, A.3
  • 23
    • 1842452811 scopus 로고    scopus 로고
    • Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer
    • Gunvant P, Baskaran M, Vijaya L, et al. Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer. Br J Ophthalmol. 2004;88(4): 518-522.
    • (2004) Br J Ophthalmol , vol.88 , Issue.4 , pp. 518-522
    • Gunvant, P.1    Baskaran, M.2    Vijaya, L.3
  • 25
    • 0031848594 scopus 로고    scopus 로고
    • Applanation tonometry and correction according to corneal thickness
    • Stodtmeister R. Applanation tonometry and correction according to corneal thickness. Acta Ophthalmol Scand. 1998;76(3):319-324.
    • (1998) Acta Ophthalmol Scand , vol.76 , Issue.3 , pp. 319-324
    • Stodtmeister, R.1
  • 26
    • 0030963090 scopus 로고    scopus 로고
    • Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam study
    • Wolfs RC, Klaver CC, Vingerling JR, Grobbee DE, Hofman A, de Jong PT. Distribution of central corneal thickness and its association with intraocular pressure: the Rotterdam study. Am J Ophthalmol. 1997;123(6):767-772.
    • (1997) Am J Ophthalmol , vol.123 , Issue.6 , pp. 767-772
    • Wolfs, R.C.1    Klaver, C.C.2    Vingerling, J.R.3    Grobbee, D.E.4    Hofman, A.5    de Jong, P.T.6
  • 28
    • 0036149032 scopus 로고    scopus 로고
    • IOP measurement and central corneal thickness
    • Stodtmeister R, Kron M, Gaus W. IOP measurement and central corneal thickness. Br J Ophthalmol. 2002;86(1):120-121.
    • (2002) Br J Ophthalmol , vol.86 , Issue.1 , pp. 120-121
    • Stodtmeister, R.1    Kron, M.2    Gaus, W.3
  • 29
    • 70349462977 scopus 로고    scopus 로고
    • Intraocular pressure adjusted for central corneal thickness as a screening tool for open-angle glaucoma in an at-risk population
    • de Saint Sardos A, Kamdeu Fansi A, Chagnon M, Harasymowycz PJ. Intraocular pressure adjusted for central corneal thickness as a screening tool for open-angle glaucoma in an at-risk population. Can J Ophthalmol. 2009;44(5):571-575.
    • (2009) Can J Ophthalmol , vol.44 , Issue.5 , pp. 571-575
    • de Saint Sardos, A.1    Kamdeu, F.A.2    Chagnon, M.3    Harasymowycz, P.J.4
  • 30
    • 18744369898 scopus 로고    scopus 로고
    • The relationship between central corneal thickness-adjusted intraocular pressure and glaucomatous visual-field loss
    • Sullivan-Mee M, Halverson KD, Saxon GB, et al. The relationship between central corneal thickness-adjusted intraocular pressure and glaucomatous visual-field loss. Optometry. 2005;76(4):228-238.
    • (2005) Optometry , vol.76 , Issue.4 , pp. 228-238
    • Sullivan-Mee, M.1    Halverson, K.D.2    Saxon, G.B.3
  • 31
    • 0033021344 scopus 로고    scopus 로고
    • Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo
    • Orssengo GJ, Pye DC. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull Math Biol. 1999;61(3):551-572.
    • (1999) Bull Math Biol , vol.61 , Issue.3 , pp. 551-572
    • Orssengo, G.J.1    Pye, D.C.2
  • 32
    • 28444475214 scopus 로고    scopus 로고
    • The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry
    • Kotecha A, White ET, Shewry JM, Garway-Heath DF. The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry. Br J Ophthalmol. 2005;89(12): 1572-1575.
    • (2005) Br J Ophthalmol , vol.89 , Issue.12 , pp. 1572-1575
    • Kotecha, A.1    White, E.T.2    Shewry, J.M.3    Garway-Heath, D.F.4
  • 33
    • 33947600358 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry and Goldmann applanation tonometry in African American subjects
    • Medeiros FA, Sample PA, Weinreb RN. Comparison of dynamic contour tonometry and Goldmann applanation tonometry in African American subjects. Ophthalmology. 2007;114(4):658-665.
    • (2007) Ophthalmology , vol.114 , Issue.4 , pp. 658-665
    • Medeiros, F.A.1    Sample, P.A.2    Weinreb, R.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.