Volumn 10, Issue 6, 2013, Pages 765-779

Non-invasive assessment of gestational hemodynamics: Benefits and limitations of impedance cardiography versus other techniques

Author keywords

bioimpedance; hemodynamics; impedance cardiography; non invasive; obstetrics; pregnancy

Indexed keywords

BIO-IMPEDANCE; CARDIAC OUTPUT; IMPEDANCE CARDIOGRAPHY; ITS APPLICATIONS; NON-INVASIVE; NON-INVASIVE ASSESSMENTS; PREGNANCY; STROKE VOLUMES;

EID: 84887789657     PISSN: 17434440     EISSN: 17452422     Source Type: Journal    
DOI: 10.1586/17434440.2013.853466     Document Type: Review
Times cited : (27)

References (105)
  • 1
    • 0014964972 scopus 로고
    • Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter
    • Swan HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N. Engl. J. Med. 283(9), 447-451 (1970
    • (1970) N. Engl. J. Med , vol.283 , Issue.9 , pp. 447-451
    • Swan, H.J.1    Ganz, W.2    Forrester, J.3    Marcus, H.4    Diamond, G.5    Chonette, D.6
  • 2
    • 0242575195 scopus 로고    scopus 로고
    • Increased risk associated with pulmonary artery catheterization in the medical intensive care unit
    • Peters SG, Afessa B, Decker PA, Schroeder DR, Offord KP, Scott JP. Increased risk associated with pulmonary artery catheterization in the medical intensive care unit. J. Crit. Care 18(3), 166-171 (2003
    • (2003) J. Crit. Care , vol.18 , Issue.3 , pp. 166-171
    • Peters, S.G.1    Afessa, B.2    Decker, P.A.3    Schroeder, D.R.4    Offord, K.P.5    Scott, J.P.6
  • 3
    • 23444461703 scopus 로고    scopus 로고
    • Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): A randomised controlled trial
    • Harvey S, Harrison DA, Singer M et al. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): A randomised controlled trial. Lancet 366(9484), 472-477 (2005
    • (2005) Lancet , vol.366 , Issue.9484 , pp. 472-477
    • Harvey, S.1    Harrison, D.A.2    Singer, M.3
  • 4
    • 14744284575 scopus 로고    scopus 로고
    • Hypertension as a hemodynamic disease: The role of impedance cardiography in diagnostic, prognostic, and therapeutic decision making
    • Ventura HO, Taler SJ, Strobeck JE. Hypertension as a hemodynamic disease: The role of impedance cardiography in diagnostic, prognostic, and therapeutic decision making. Am. J. Hypertens. 18(2 Pt 2), 26S-43S (2005
    • (2005) Am. J. Hypertens , vol.18 , Issue.2 PART 2
    • Ventura, H.O.1    Taler, S.J.2    Strobeck, J.E.3
  • 6
    • 0018672505 scopus 로고
    • Measurements of cardiac stroke volume in various body positions in pregnancy and during Caesarean section: A comparison between thermodilution and impedance cardiography
    • Secher NJ, Arnsbo P, Andersen LH, Thomsen A. Measurements of cardiac stroke volume in various body positions in pregnancy and during Caesarean section: A comparison between thermodilution and impedance cardiography. Scand. J. Clin. Lab Invest. 39(6), 569-576 (1979
    • (1979) Scand. J. Clin. Lab Invest , vol.39 , Issue.6 , pp. 569-576
    • Secher, N.J.1    Arnsbo, P.2    Andersen, L.H.3    Thomsen, A.4
  • 7
    • 0024468279 scopus 로고
    • Measurement of cardiac output in pregnancy by thoracic electrical bioimpedance and thermodilution a preliminary report
    • Masaki DI, Greenspoon JS, Ouzounian JG. Measurement of cardiac output in pregnancy by thoracic electrical bioimpedance and thermodilution. A preliminary report. Am. J. Obstet. Gynecol. 161(3), 680-684 (1989
    • (1989) Am. J. Obstet. Gynecol , vol.161 , Issue.3 , pp. 680-684
    • Masaki, D.I.1    Greenspoon, J.S.2    Ouzounian, J.G.3
  • 8
    • 84866174627 scopus 로고    scopus 로고
    • Impedance cardiography in uncomplicated pregnancy and pre-eclampsia: A reliability study
    • Tomsin K, Mesens T, Molenberghs G, Gyselaers W. Impedance cardiography in uncomplicated pregnancy and pre-eclampsia: A reliability study. J. Obstet. Gynaecol. 32(7), 630-634 (2012
    • (2012) J. Obstet. Gynaecol , vol.32 , Issue.7 , pp. 630-634
    • Tomsin, K.1    Mesens, T.2    Molenberghs, G.3    Gyselaers, W.4
  • 9
    • 84859921319 scopus 로고    scopus 로고
    • Venous pulse transit time in normal pregnancy and preeclampsia
    • Tomsin K, Mesens T, Molenberghs G, Gyselaers W. Venous pulse transit time in normal pregnancy and preeclampsia. Reprod. Sci. 19(4), 431-436 (2012
    • (2012) Reprod. Sci , vol.19 , Issue.4 , pp. 431-436
    • Tomsin, K.1    Mesens, T.2    Molenberghs, G.3    Gyselaers, W.4
  • 10
    • 84861170028 scopus 로고    scopus 로고
    • Hemodynamic evaluation in pregnancy: Limitations of impedance cardiography
    • Moertl MG, Schlembach D, Papousek I et al. Hemodynamic evaluation in pregnancy: Limitations of impedance cardiography. Physiol. Meas. 33(6), 1015-1026 (2012
    • (2012) Physiol. Meas , vol.33 , Issue.6 , pp. 1015-1026
    • Moertl, M.G.1    Schlembach, D.2    Papousek, I.3
  • 11
    • 45149136659 scopus 로고
    • The basic shape of the arterial pulse first treatise: Mathematical analysis 1899
    • Frank O. The basic shape of the arterial pulse. First treatise: Mathematical analysis. 1899. J. Mol. Cell Cardiol. 22(3), 255-277( 1990
    • (1990) J. Mol. Cell Cardiol , vol.22 , Issue.3 , pp. 255-277
    • Frank, O.1
  • 12
    • 0027219058 scopus 로고
    • A new method of measuring cardiac output in man using lithium dilution
    • Linton RA, Band DM, Haire KM. A new method of measuring cardiac output in man using lithium dilution. Br. J. Anaesth. 71(2), 262-266 (1993
    • (1993) Br. J. Anaesth , vol.71 , Issue.2 , pp. 262-266
    • Linton, R.A.1    Band, D.M.2    Haire, K.M.3
  • 14
    • 67849110105 scopus 로고    scopus 로고
    • Perioperative hemodynamic monitoring with transesophageal doppler technology
    • Schober P, Loer SA, Schwarte LA. Perioperative hemodynamic monitoring with transesophageal Doppler technology. Anesth. Analg. 109(2), 340-353( 2009
    • (2009) Anesth. Analg , vol.109 , Issue.2 , pp. 340-353
    • Schober, P.1    Loer, S.A.2    Schwarte, L.A.3
  • 15
    • 78049343101 scopus 로고    scopus 로고
    • Minimally invasive measurement of cardiac output during surgery and critical care: A meta-analysis of accuracy and precision
    • Peyton PJ, Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: A meta-analysis of accuracy and precision. Anesthesiology 113(5), 1220-1235 (2010
    • (2010) Anesthesiology , vol.113 , Issue.5 , pp. 1220-1235
    • Peyton, P.J.1    Chong, S.W.2
  • 16
    • 0036481560 scopus 로고    scopus 로고
    • Recommendations for quantification of doppler echocardiography: A report from the doppler quantification task force of the nomenclature and standards committee of the american society of echocardiography
    • Quinones MA, Otto CM, Stoddard M, Waggoner A, Zoghbi WA. Recommendations for quantification of Doppler echocardiography: A report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. J. Am. Soc. Echocardiogr. 15(2), 167-184 (2002
    • (2002) J. Am. Soc. Echocardiogr , vol.15 , Issue.2 , pp. 167-184
    • Quinones, M.A.1    Otto, C.M.2    Stoddard, M.3    Waggoner, A.4    Zoghbi, W.A.5
  • 17
    • 70449727097 scopus 로고    scopus 로고
    • European Association of Echocardiography recommendations for training, competence, and quality improvement in echocardiography
    • Popescu BA, Andrade MJ, Badano LP et al. European Association of Echocardiography recommendations for training, competence, and quality improvement in echocardiography. Eur. J. Echocardiogr. 10(8), 893-905 (2009
    • (2009) Eur. J. Echocardiogr , vol.10 , Issue.8 , pp. 893-905
    • Popescu, B.A.1    Andrade, M.J.2    Badano, L.P.3
  • 18
    • 0029194530 scopus 로고
    • Guidelines for training in adult cardiovascular medicine core cardiology training symposium (cocats) task force 4: Training in echocardiography
    • Stewart WJ, Aurigemma GP, Bierman FZ et al. Guidelines for training in adult cardiovascular medicine. Core Cardiology Training Symposium (COCATS). Task Force 4: Training in echocardiography. J. Am. Coll. Cardiol. 25(1), 16-19( 1995
    • (1995) J. Am. Coll. Cardiol , vol.25 , Issue.1 , pp. 16-19
    • Stewart, W.J.1    Aurigemma, G.P.2    Bierman, F.Z.3
  • 19
    • 84858342283 scopus 로고    scopus 로고
    • A comparison of the nexfin(r) and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery
    • Broch O, Renner J, Gruenewald M et al. A comparison of the Nexfin(R) and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery. Anaesthesia 67(4), 377-383( 2012
    • (2012) Anaesthesia , vol.67 , Issue.4 , pp. 377-383
    • Broch, O.1    Renner, J.2    Gruenewald, M.3
  • 20
    • 34547132055 scopus 로고    scopus 로고
    • Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance
    • Keren H, Burkhoff D, Squara P. Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am. J. Physiol. Heart Circ. Physiol. 293(1), H583-H589 (2007
    • (2007) Am. J. Physiol. Heart Circ. Physiol , vol.293 , Issue.1
    • Keren, H.1    Burkhoff, D.2    Squara, P.3
  • 21
    • 0022980897 scopus 로고
    • A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale
    • Bernstein DP. A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale. Crit. Care Med. 14(10), 904-909 (1986
    • (1986) Crit. Care Med , vol.14 , Issue.10 , pp. 904-909
    • Bernstein, D.P.1
  • 22
    • 0020117097 scopus 로고
    • Cardiac output by electrical impedance
    • Sramek BB. Cardiac output by electrical impedance. Med. Electron. 13(2), 93-97( 1982
    • (1982) Med. Electron , vol.13 , Issue.2 , pp. 93-97
    • Sramek, B.B.1
  • 23
    • 0022979027 scopus 로고
    • Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance
    • Bernstein DP. Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance. Crit. Care Med. 14(10), 898-901 (1986
    • (1986) Crit. Care Med , vol.14 , Issue.10 , pp. 898-901
    • Bernstein, D.P.1
  • 24
    • 78650148104 scopus 로고    scopus 로고
    • Measurement of cardiac output with non-invasive Aesculon impedance versus thermodilution
    • Petter H, Erik A, Bjorn E, Goran R. Measurement of cardiac output with non-invasive Aesculon impedance versus thermodilution. Clin. Physiol. Funct. Imaging. 31(1), 39-47 (2011
    • (2011) Clin. Physiol. Funct. Imaging , vol.31 , Issue.1 , pp. 39-47
    • Petter, H.1    Erik, A.2    Bjorn, E.3    Goran, R.4
  • 25
    • 84856954655 scopus 로고    scopus 로고
    • Thoracic impedance change equation deduced on the basis of parallel impedance model and ohm's law
    • Qiu-Jin X, ZhenW, Ming-Xing K, PingW, Pei L, Jian-Feng J. Thoracic impedance change equation deduced on the basis of parallel impedance model and Ohm's law. Med. Phys. 39(2), 1042-1045 (2012
    • (2012) Med. Phys , vol.39 , Issue.2 , pp. 1042-1045
    • Qiu-Jin, X.1    Zhenw Ming-Xing, K.2    Pingw Pei, L.3    Jian-Feng, J.4
  • 27
    • 79851504678 scopus 로고    scopus 로고
    • Diurnal and position-induced variability of impedance cardiography measurements in healthy subjects
    • Tomsin K, Mesens T, Molenberghs G, Gyselaers W. Diurnal and position-induced variability of impedance cardiography measurements in healthy subjects. Clin. Physiol. Funct. Imaging. 31(2), 145-150( 2011
    • (2011) Clin. Physiol. Funct. Imaging , vol.31 , Issue.2 , pp. 145-150
    • Tomsin, K.1    Mesens, T.2    Molenberghs, G.3    Gyselaers, W.4
  • 28
    • 77955938970 scopus 로고    scopus 로고
    • Transthoracic bioimpedance and brain natriuretic peptide levels accurately indicate additional diastolic dysfunction in patients with chronic advanced systolic heart failure
    • Malfatto G, Branzi G, Giglio A et al. Transthoracic bioimpedance and brain natriuretic peptide levels accurately indicate additional diastolic dysfunction in patients with chronic advanced systolic heart failure. Eur. J. Heart Fail. 12(9), 928-935 (2010
    • (2010) Eur. J. Heart Fail , vol.12 , Issue.9 , pp. 928-935
    • Malfatto, G.1    Branzi, G.2    Giglio, A.3
  • 30
    • 0028500275 scopus 로고
    • Reproducibility of estimated cardiovascular function by transthoracic bioimpedance cardiography in healthy volunteers
    • van Oppen AC, van Der Tweel I, Bruinse HW. Reproducibility of estimated cardiovascular function by transthoracic bioimpedance cardiography in healthy volunteers. Int. J. Biomed. Comput. 37(1), 15-18 (1994
    • (1994) Int. J. Biomed. Comput , vol.37 , Issue.1 , pp. 15-18
    • Van Oppen, A.C.1    Van Der Tweel, I.2    Bruinse, H.W.3
  • 31
    • 84860687989 scopus 로고    scopus 로고
    • Reproducibility of cardia output derived by impedance cardiography during postural changes and exercise
    • Schultz M, Climie R, Nikolic S, Ahuja K, Sharman J. Reproducibility of cardia output derived by impedance cardiography during postural changes and exercise. Artery Res. 6(2), 78-84 (2012
    • (2012) Artery Res , vol.6 , Issue.2 , pp. 78-84
    • Schultz, M.1    Climie, R.2    Nikolic, S.3    Ahuja, K.4    Sharman, J.5
  • 32
    • 3042785009 scopus 로고    scopus 로고
    • Evaluation of impedance cardiography as an alternative to pulmonary artery catheterization in critically ill patients
    • Silver MA, Cianci P, Brennan S, Longeran-Thomas H, Ahmad F. Evaluation of impedance cardiography as an alternative to pulmonary artery catheterization in critically ill patients. Congest. Heart Fail. 10( 2 Suppl. 2), 17-21 (2004
    • (2004) Congest. Heart Fail , vol.10 , Issue.2 SUPPL. 2 , pp. 17-21
    • Silver, M.A.1    Cianci, P.2    Brennan, S.3    Longeran-Thomas, H.4    Ahmad, F.5
  • 33
    • 23744481477 scopus 로고    scopus 로고
    • Comparison of impedance cardiography and thermodilution-derived measurements of stroke volume and cardiac output at rest and during exercise testing
    • Scherhag A, Kaden JJ, Kentschke E, Sueselbeck T, Borggrefe M. Comparison of impedance cardiography and thermodilution-derived measurements of stroke volume and cardiac output at rest and during exercise testing. Cardiovasc. Drugs Ther. 19(2), 141-147 (2005
    • (2005) Cardiovasc. Drugs Ther , vol.19 , Issue.2 , pp. 141-147
    • Scherhag, A.1    Kaden, J.J.2    Kentschke, E.3    Sueselbeck, T.4    Borggrefe, M.5
  • 34
    • 0029003059 scopus 로고
    • Evaluation of impedance cardiography: Comparison of NCCOM3-R7 with Fick and thermodilution methods
    • Yakimets J, Jensen L. Evaluation of impedance cardiography: Comparison of NCCOM3-R7 with Fick and thermodilution methods. Heart Lung 24(3), 194-206 (1995
    • (1995) Heart Lung , vol.24 , Issue.3 , pp. 194-206
    • Yakimets, J.1    Jensen, L.2
  • 35
  • 36
    • 70349314268 scopus 로고    scopus 로고
    • A multicenter study of noninvasive cardiac output by bioreactance during symptom-limited exercise
    • Maurer MM, Burkhoff D, Maybaum S et al. A multicenter study of noninvasive cardiac output by bioreactance during symptom-limited exercise. J. Card. Fail. 15(8), 689-699 (2009
    • (2009) J. Card. Fail , vol.15 , Issue.8 , pp. 689-699
    • Maurer, M.M.1    Burkhoff, D.2    Maybaum, S.3
  • 37
    • 34848909003 scopus 로고    scopus 로고
    • Cardiac output and cardiopulmonary responses to exercise in heart failure: Application of a new bio-reactance device
    • Myers J, Gujja P, Neelagaru S, Burkhoff D. Cardiac output and cardiopulmonary responses to exercise in heart failure: Application of a new bio-reactance device. J. Card. Fail. 13(8), 629-636 (2007
    • (2007) J. Card. Fail , vol.13 , Issue.8 , pp. 629-636
    • Myers, J.1    Gujja, P.2    Neelagaru, S.3    Burkhoff, D.4
  • 38
    • 0030585698 scopus 로고    scopus 로고
    • Comparison of impedance cardiography with thermodilution and direct Fick methods for noninvasive measurement of stroke volume and cardiac output during incremental exercise in patients with ischemic cardiomyopathy
    • Belardinelli R, Ciampani N, Costantini C, Blandini A, Purcaro A. Comparison of impedance cardiography with thermodilution and direct Fick methods for noninvasive measurement of stroke volume and cardiac output during incremental exercise in patients with ischemic cardiomyopathy. Am. J. Cardiol. 77(15), 1293-1301 (1996
    • (1996) Am. J. Cardiol , vol.77 , Issue.15 , pp. 1293-1301
    • Belardinelli, R.1    Ciampani, N.2    Costantini, C.3    Blandini, A.4    Purcaro, A.5
  • 39
    • 0037090669 scopus 로고    scopus 로고
    • Comparison of impedance cardiography with invasive hemodynamic measurements in patients with heart failure secondary to ischemic or nonischemic cardiomyopathy
    • Drazner MH, Thompson B, Rosenberg PB et al. Comparison of impedance cardiography with invasive hemodynamic measurements in patients with heart failure secondary to ischemic or nonischemic cardiomyopathy. Am. J. Cardiol. 89(8), 993-995 (2002
    • (2002) Am. J. Cardiol , vol.89 , Issue.8 , pp. 993-995
    • Drazner, M.H.1    Thompson, B.2    Rosenberg, P.B.3
  • 41
    • 3042738343 scopus 로고    scopus 로고
    • Comparison of impedance cardiography to direct Fick and thermodilution cardiac output determination in pulmonary arterial hypertension
    • Yung GL, Fedullo PF, Kinninger K, Johnson W, Channick RN. Comparison of impedance cardiography to direct Fick and thermodilution cardiac output determination in pulmonary arterial hypertension. Congest. Heart Fail. 10( 2 Suppl. 2), 7-10 (2004
    • (2004) Congest. Heart Fail , vol.10 , Issue.2 SUPPL. 2 , pp. 7-10
    • Yung, G.L.1    Fedullo, P.F.2    Kinninger, K.3    Johnson, W.4    Channick, R.N.5
  • 42
    • 33646435857 scopus 로고    scopus 로고
    • Impedance cardiography: More questions than answers
    • Wang DJ, Gottlieb SS. Impedance cardiography: More questions than answers. Curr. Cardiol. Rep. 8(3), 180-186 (2006
    • (2006) Curr. Cardiol. Rep , vol.8 , Issue.3 , pp. 180-186
    • Wang, D.J.1    Gottlieb, S.S.2
  • 43
    • 43349098041 scopus 로고    scopus 로고
    • Assessment of stroke volume index with three different bioimpedance algorithms: Lack of agreement compared to thermodilution
    • De Waal EE, Konings MK, Kalkman CJ, Buhre WF. Assessment of stroke volume index with three different bioimpedance algorithms: Lack of agreement compared to thermodilution. Intensive Care Med. 34(4), 735-739 (2008
    • (2008) Intensive Care Med , vol.34 , Issue.4 , pp. 735-739
    • De Waal, E.E.1    Konings, M.K.2    Kalkman, C.J.3    Buhre, W.F.4
  • 44
    • 2442673375 scopus 로고    scopus 로고
    • Accurate, noninvasive continuous monitoring of cardiac output by whole-body electrical bioimpedance
    • Cotter G, Moshkovitz Y, Kaluski E et al. Accurate, noninvasive continuous monitoring of cardiac output by whole-body electrical bioimpedance. Chest 125(4), 1431-1440 (2004
    • (2004) Chest , vol.125 , Issue.4 , pp. 1431-1440
    • Cotter, G.1    Moshkovitz, Y.2    Kaluski, E.3
  • 45
    • 0028149502 scopus 로고
    • Maternal cardiovascular hemodynamic adaptation to pregnancy
    • Duvekot JJ, Peeters LL. Maternal cardiovascular hemodynamic adaptation to pregnancy. Obstet. Gynecol. Surv. 49(Suppl. 12), S1-S14 (1994
    • (1994) Obstet. Gynecol. Surv , vol.49 , Issue.SUPPL. 12
    • Duvekot, J.J.1    Peeters, L.L.2
  • 47
    • 84867781689 scopus 로고    scopus 로고
    • Massive pulmonary embolism in a patient undergoing cesarean delivery
    • Ayad S, Tetzlaff JE. Massive pulmonary embolism in a patient undergoing Cesarean delivery. J. Clin. Anesth. 24(7), 582-585( 2012
    • (2012) J. Clin. Anesth , vol.24 , Issue.7 , pp. 582-585
    • Ayad, S.1    Tetzlaff, J.E.2
  • 48
    • 84866429456 scopus 로고    scopus 로고
    • Surgical repair of atrial septal defect with severe pulmonary hypertension during pregnancy: A case report with literature review
    • Manivannan S, Dadlani G, Parsons M et al. Surgical repair of atrial septal defect with severe pulmonary hypertension during pregnancy: A case report with literature review. Cardiol. Young. 22(5), 493-498( 2012
    • (2012) Cardiol. Young , vol.22 , Issue.5 , pp. 493-498
    • Manivannan, S.1    Dadlani, G.2    Parsons, M.3
  • 49
    • 48849090171 scopus 로고    scopus 로고
    • General anesthesia using remifentanil for cesarean delivery in a parturient with marfan's syndrome
    • Singh SI, Brooks C, Dobkowski W. General anesthesia using remifentanil for Cesarean delivery in a parturient with Marfan's syndrome. Can. J. Anaesth. 55(8), 526-531( 2008
    • (2008) Can. J. Anaesth , vol.55 , Issue.8 , pp. 526-531
    • Singh, S.I.1    Brooks, C.2    Dobkowski, W.3
  • 50
    • 62149096861 scopus 로고    scopus 로고
    • Fulminant peripartum cardiomyopathy rescue with extracorporeal membranous oxygenation
    • Smith IJ, Gillham MJ. Fulminant peripartum cardiomyopathy rescue with extracorporeal membranous oxygenation. Int. J. Obstet. Anesth. 18(2), 186-188( 2009
    • (2009) Int. J. Obstet. Anesth , vol.18 , Issue.2 , pp. 186-188
    • Smith, I.J.1    Gillham, M.J.2
  • 51
    • 78149487517 scopus 로고    scopus 로고
    • Successful surgical management of massive pulmonary embolism during the second trimester in a parturient with heparin-induced thrombocytopenia
    • Hajj-Chahine J, Jayle C, Tomasi J, Corbi P. Successful surgical management of massive pulmonary embolism during the second trimester in a parturient with heparin-induced thrombocytopenia. Interact. Cardiovasc. Thorac. Surg. 11(5), 679-681( 2010).
    • (2010) Interact. Cardiovasc. Thorac. Surg , vol.11 , Issue.5 , pp. 679-681
    • Hajj-Chahine, J.1    Jayle, C.2    Tomasi, J.3    Corbi, P.4
  • 52
    • 0023261004 scopus 로고
    • Measurement of cardiac output during pregnancy: Validation of Doppler technique and clinical observations in preeclampsia
    • Easterling TR, Watts DH, Schmucker BC, Benedetti TJ. Measurement of cardiac output during pregnancy: Validation of Doppler technique and clinical observations in preeclampsia. Obstet. Gynecol. 69(6), 845-850 (1987
    • (1987) Obstet. Gynecol , vol.69 , Issue.6 , pp. 845-850
    • Easterling, T.R.1    Watts, D.H.2    Schmucker, B.C.3    Benedetti, T.J.4
  • 53
    • 0023851265 scopus 로고
    • Noninvasive maternal stroke volume and cardiac output determinations by pulsed doppler echocardiography
    • Lee W, Rokey R, Cotton DB. Noninvasive maternal stroke volume and cardiac output determinations by pulsed Doppler echocardiography. Am. J. Obstet. Gynecol. 158(3 Pt 1), 505-510 (1988
    • (1988) Am. J. Obstet. Gynecol , vol.158 , Issue.3 PART 1 , pp. 505-510
    • Lee, W.1    Rokey, R.2    Cotton, D.B.3
  • 56
    • 0025992985 scopus 로고
    • Ventilatory drive and respiratory muscle function in pregnancy
    • Contreras G, Gutierrez M, Beroiza T et al. Ventilatory drive and respiratory muscle function in pregnancy. Am. Rev. Respir. Dis. 144(4), 837-841 (1991
    • (1991) Am. Rev. Respir. Dis , vol.144 , Issue.4 , pp. 837-841
    • Contreras, G.1    Gutierrez, M.2    Beroiza, T.3
  • 58
    • 80053997333 scopus 로고    scopus 로고
    • Hemodynamic changes during pregnancy and postpartum: A prospective study using thoracic electrical bioimpedance
    • San Frutos L, Engels V, Zapardiel I et al. Hemodynamic changes during pregnancy and postpartum: A prospective study using thoracic electrical bioimpedance. J. Matern. Fetal Neonatal Med. 24(11), 1333-1340( 2011
    • (2011) J. Matern. Fetal Neonatal Med , vol.24 , Issue.11 , pp. 1333-1340
    • San Frutos, L.1    Engels, V.2    Zapardiel, I.3
  • 59
    • 0020523910 scopus 로고
    • Measurement of cardiac stroke volume during cesarean section: A comparison between impedance cardiography and the dye dilution technique
    • Milsom I, Forssman L, Biber B, Dottori O, Sivertsson R. Measurement of cardiac stroke volume during cesarean section: A comparison between impedance cardiography and the dye dilution technique. Acta Anaesthesiol. Scand. 27(5), 421-426 (1983
    • (1983) Acta Anaesthesiol. Scand , vol.27 , Issue.5 , pp. 421-426
    • Milsom, I.1    Forssman, L.2    Biber, B.3    Dottori, O.4    Sivertsson, R.5
  • 60
    • 0021022289 scopus 로고
    • Measurement of cardiac stroke volume by impedance cardiography in the last trimester of pregnancy
    • Milsom I, Forssman L, Sivertsson R, Dottori O. Measurement of cardiac stroke volume by impedance cardiography in the last trimester of pregnancy. Acta Obstet. Gynecol. Scand. 62(5), 473-479 (1983
    • (1983) Acta Obstet. Gynecol. Scand , vol.62 , Issue.5 , pp. 473-479
    • Milsom, I.1    Forssman, L.2    Sivertsson, R.3    Dottori, O.4
  • 61
    • 0025010908 scopus 로고
    • Measurement of cardiac output by impedance technique
    • Easterling TR, Benedetti TJ. Measurement of cardiac output by impedance technique. Am. J. Obstet. Gynecol. 163(3), 1104-1106( 1990
    • (1990) Am. J. Obstet. Gynecol , vol.163 , Issue.3 , pp. 1104-1106
    • Easterling, T.R.1    Benedetti, T.J.2
  • 62
    • 0028318799 scopus 로고
    • A comparison of cardiac index in normal term pregnancy using thoracic electrical bio-impedance and oxygen extraction (fick) techniques
    • Clark SL, Southwick J, Pivarnik JM, Cotton DB, Hankins GD, Phelan JP. A comparison of cardiac index in normal term pregnancy using thoracic electrical bio-impedance and oxygen extraction (Fick) techniques. Obstet. Gynecol. 83(5 Pt 1), 669-672 (1994
    • (1994) Obstet. Gynecol , vol.83 , Issue.5 PART 1 , pp. 669-672
    • Clark, S.L.1    Southwick, J.2    Pivarnik, J.M.3    Cotton, D.B.4    Hankins, G.D.5    Phelan, J.P.6
  • 63
    • 0024567011 scopus 로고
    • Serial study of factors influencing changes in cardiac output during human pregnancy
    • Robson SC, Hunter S, Boys RJ, Dunlop W. Serial study of factors influencing changes in cardiac output during human pregnancy. Am. J. Physiol. 256(4 Pt 2), H1060-H1065( 1989
    • (1989) Am. J. Physiol , vol.256 , Issue.4 PART 2
    • Robson, S.C.1    Hunter, S.2    Boys, R.J.3    Dunlop, W.4
  • 64
    • 77952281721 scopus 로고    scopus 로고
    • A longitudinal study of the relationship between maternal cardiac output measured by impedance cardiography and uterine artery blood flow in the second half of pregnancy
    • Flo K, Wilsgaard T, Vartun A, Acharya G. A longitudinal study of the relationship between maternal cardiac output measured by impedance cardiography and uterine artery blood flow in the second half of pregnancy. BJOG 117(7), 837-844 (2010
    • (2010) BJOG , vol.117 , Issue.7 , pp. 837-844
    • Flo, K.1    Wilsgaard, T.2    Vartun, A.3    Acharya, G.4
  • 65
    • 34247094311 scopus 로고    scopus 로고
    • Haemodynamic changes in the second half of pregnancy: A longitudinal, noninvasive study with thoracic electrical bioimpedance
    • Volman MN, Rep A, Kadzinska I et al. Haemodynamic changes in the second half of pregnancy: A longitudinal, noninvasive study with thoracic electrical bioimpedance. BJOG 114(5), 576-581 (2007
    • (2007) BJOG , vol.114 , Issue.5 , pp. 576-581
    • Volman, M.N.1    Rep, A.2    Kadzinska, I.3
  • 68
    • 67650245058 scopus 로고    scopus 로고
    • Maternal hepatic vein Doppler velocimetry during uncomplicated pregnancy and pre-eclampsia
    • Gyselaers W, Molenberghs G, Mesens T, Peeters L. Maternal hepatic vein Doppler velocimetry during uncomplicated pregnancy and pre-eclampsia. Ultrasound Med. Biol. 35(8), 1278-1283( 2009
    • (2009) Ultrasound Med. Biol , vol.35 , Issue.8 , pp. 1278-1283
    • Gyselaers, W.1    Molenberghs, G.2    Mesens, T.3    Peeters, L.4
  • 69
    • 0347985644 scopus 로고    scopus 로고
    • Delivery before 32 weeks of gestation for maternal pre-eclampsia: Neonatal outcome and 2-year developmental outcome
    • Cheng SW, Chou HC, Tsou KI, Fang LJ, Tsao PN. Delivery before 32 weeks of gestation for maternal pre-eclampsia: Neonatal outcome and 2-year developmental outcome. Early Hum. Dev. 76(1), 39-46( 2004
    • (2004) Early Hum. Dev , vol.76 , Issue.1 , pp. 39-46
    • Cheng, S.W.1    Chou, H.C.2    Tsou, K.I.3    Fang, L.J.4    Tsao, P.N.5
  • 70
    • 65649096597 scopus 로고    scopus 로고
    • Predicting adverse outcomes in women with severe pre-eclampsia
    • von Dadelszen P, Menzies JM, Payne B, Magee LA. Predicting adverse outcomes in women with severe pre-eclampsia. Semin. Perinatol. 33(3), 152-157 (2009
    • (2009) Semin. Perinatol , vol.33 , Issue.3 , pp. 152-157
    • Von Dadelszen, P.1    Menzies, J.M.2    Payne, B.3    Magee, L.A.4
  • 71
    • 0024585784 scopus 로고
    • Measurement of cardiac output in pregnancy by thermodilution and impedance techniques
    • Easterling TR, Benedetti TJ, Carlson KL, Watts DH. Measurement of cardiac output in pregnancy by thermodilution and impedance techniques. Br. J. Obstet. Gynaecol. 96(1), 67-69 (1989
    • (1989) Br. J. Obstet. Gynaecol , vol.96 , Issue.1 , pp. 67-69
    • Easterling, T.R.1    Benedetti, T.J.2    Carlson, K.L.3    Watts, D.H.4
  • 73
    • 84862859077 scopus 로고    scopus 로고
    • Impedance cardiography facilitates differentiation of severe and superimposed preeclampsia from other hypertensive disorders
    • Parrish MR, Laye MR, Wood T et al. Impedance cardiography facilitates differentiation of severe and superimposed preeclampsia from other hypertensive disorders. Hypertens. Pregnancy 31(3), 327-340 (2012
    • (2012) Hypertens. Pregnancy , vol.31 , Issue.3 , pp. 327-340
    • Parrish, M.R.1    Laye, M.R.2    Wood, T.3
  • 74
    • 0033026943 scopus 로고    scopus 로고
    • Thoracic-fluid conductivity in peripartum women with pulmonary edema
    • Newman RB, Pierre H, Scardo J. Thoracic-fluid conductivity in peripartum women with pulmonary edema. Obstet. Gynecol. 94(1), 48-51 (1999
    • (1999) Obstet. Gynecol , vol.94 , Issue.1 , pp. 48-51
    • Newman, R.B.1    Pierre, H.2    Scardo, J.3
  • 75
    • 0033170927 scopus 로고    scopus 로고
    • Cost-effectiveness of noninvasive hemodynamic monitoring
    • Hendrickson K. Cost-effectiveness of noninvasive hemodynamic monitoring. AACN Clin. Issues. 10(3), 419-424( 1999
    • (1999) AACN Clin. Issues , vol.10 , Issue.3 , pp. 419-424
    • Hendrickson, K.1
  • 76
    • 34247465511 scopus 로고    scopus 로고
    • Impedance cardiography: A valuable method of evaluating haemodynamic parameters
    • Sodolski T, Kutarski A. Impedance cardiography: A valuable method of evaluating haemodynamic parameters. Cardiol. J. 14(2), 115-126 (2007
    • (2007) Cardiol. J. , vol.14 , Issue.2 , pp. 115-126
    • Sodolski, T.1    Kutarski, A.2
  • 77
    • 1842451793 scopus 로고    scopus 로고
    • Non-invasive cardiac output monitoring
    • Hett DA, Jonas MM. Non-invasive cardiac output monitoring. Intensive Crit. Care Nurs. 20(2), 103-108 (2004
    • (2004) Intensive Crit. Care Nurs , vol.20 , Issue.2 , pp. 103-108
    • Hett, D.A.1    Jonas, M.M.2
  • 79
    • 0033931336 scopus 로고    scopus 로고
    • Simultaneous comparison of thoracic bioimpedance and arterial pulse waveform-derived cardiac output with thermodilution measurement
    • Hirschl MM, Kittler H, Woisetschlager C et al. Simultaneous comparison of thoracic bioimpedance and arterial pulse waveform-derived cardiac output with thermodilution measurement. Crit. Care Med. 28(6), 1798-1802 (2000
    • (2000) Crit. Care Med , vol.28 , Issue.6 , pp. 1798-1802
    • Hirschl, M.M.1    Kittler, H.2    Woisetschlager, C.3
  • 80
    • 79953674181 scopus 로고    scopus 로고
    • Measurement of cardiac output in children by bioreactance
    • Ballestero Y, Lopez-Herce J, Urbano J et al. Measurement of cardiac output in children by bioreactance. Pediatr. Cardiol. 32(4), 469-472 (2011
    • (2011) Pediatr. Cardiol , vol.32 , Issue.4 , pp. 469-472
    • Ballestero, Y.1    Lopez-Herce, J.2    Urbano, J.3
  • 81
    • 80053570433 scopus 로고    scopus 로고
    • A comparison of cardiac output by thoracic impedance and direct fick in children with congenital heart disease undergoing diagnostic cardiac catheterization
    • Taylor K, La Rotta G, McCrindle BW, Manlhiot C, Redington A, Holtby H. A comparison of cardiac output by thoracic impedance and direct Fick in children with congenital heart disease undergoing diagnostic cardiac catheterization. J. Cardiothorac. Vasc. Anesth. 25(5), 776-779 (2011
    • (2011) J. Cardiothorac. Vasc. Anesth , vol.25 , Issue.5 , pp. 776-779
    • Taylor, K.1    La Rotta, G.2    McCrindle, B.W.3    Manlhiot, C.4    Redington, A.5    Holtby, H.6
  • 82
    • 34547134966 scopus 로고    scopus 로고
    • An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgery
    • De Wilde RB, Schreuder JJ, Van Den Berg PC, Jansen JR. An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgery. Anaesthesia 62(8), 760-768 (2007
    • (2007) Anaesthesia , vol.62 , Issue.8 , pp. 760-768
    • De Wilde, R.B.1    Schreuder, J.J.2    Van Den Berg, P.C.3    Jansen, J.R.4
  • 83
    • 38849093827 scopus 로고    scopus 로고
    • Continuous and intermittent cardiac output measurement in hyperdynamic conditions: Pulmonary artery catheter vs lithium dilution technique
    • Costa MG, Della Rocca G, Chiarandini P et al. Continuous and intermittent cardiac output measurement in hyperdynamic conditions: Pulmonary artery catheter vs lithium dilution technique. Intensive Care Med. 34(2), 257-263 (2008
    • (2008) Intensive Care Med , vol.34 , Issue.2 , pp. 257-263
    • Costa, M.G.1    Della Rocca, G.2    Chiarandini, P.3
  • 84
    • 0029090208 scopus 로고
    • Continuous measurement of cardiac output with pulse contour analysis
    • Irlbeck M, Forst H, Briegel J, Haller M, Peter K. Continuous measurement of cardiac output with pulse contour analysis. Anaesthesist. 44(7), 493-500 (1995
    • (1995) Anaesthesist , vol.44 , Issue.7 , pp. 493-500
    • Irlbeck, M.1    Forst, H.2    Briegel, J.3    Haller, M.4    Peter, K.5
  • 85
    • 0036198399 scopus 로고    scopus 로고
    • Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique
    • Della Rocca G, Costa MG, Pompei L, Coccia C, Pietropaoli P. Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique. Br. J. Anaesth. 88(3), 350-356 (2002
    • (2002) Br. J. Anaesth , vol.88 , Issue.3 , pp. 350-356
    • Della Rocca, G.1    Costa, M.G.2    Pompei, L.3    Coccia, C.4    Pietropaoli, P.5
  • 86
    • 0142149221 scopus 로고    scopus 로고
    • Cardiac output monitoring: Aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation
    • Della Rocca G, Costa MG, Coccia C et al. Cardiac output monitoring: Aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation. Can. J. Anaesth. 50(7), 707-711 (2003
    • (2003) Can. J. Anaesth , vol.50 , Issue.7 , pp. 707-711
    • Della Rocca, G.1    Costa, M.G.2    Coccia, C.3
  • 88
    • 0042482769 scopus 로고    scopus 로고
    • Continuous cardiac output measurement: Pulse contour analysis vs thermodilution technique in cardiac surgical patients
    • Rodig G, Prasser C, Keyl C, Liebold A, Hobbhahn J. Continuous cardiac output measurement: Pulse contour analysis vs thermodilution technique in cardiac surgical patients. Br. J. Anaesth. 82(4), 525-530( 1999
    • (1999) Br. J. Anaesth , vol.82 , Issue.4 , pp. 525-530
    • Rodig, G.1    Prasser, C.2    Keyl, C.3    Liebold, A.4    Hobbhahn, J.5
  • 89
    • 84887731414 scopus 로고    scopus 로고
    • Performance of a new pulse contour method for continuous cardiac output monitoring: Validation in critically ill patients
    • Bendjelid K, Marx G, Kiefer N et al. Performance of a new pulse contour method for continuous cardiac output monitoring: Validation in critically ill patients. Br. J. Anaesth. 111(4), 573-579( 2013
    • (2013) Br. J. Anaesth , vol.111 , Issue.4 , pp. 573-579
    • Bendjelid, K.1    Marx, G.2    Kiefer, N.3
  • 90
    • 0036152801 scopus 로고    scopus 로고
    • Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability
    • Godje O, Hoke K, Goetz AE et al. Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability. Crit. Care Med. 30(1), 52-58( 2002
    • (2002) Crit. Care Med , vol.30 , Issue.1 , pp. 52-58
    • Godje, O.1    Hoke, K.2    Goetz, A.E.3
  • 91
    • 84881370424 scopus 로고    scopus 로고
    • Noninvasive continuous cardiac output by the nexfin before and after preload-modifying maneuvers: A comparison with intermittent thermodilution cardiac output
    • Bubenek-Turconi SI, Craciun M, Miclea I, Perel A. Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: A comparison with intermittent thermodilution cardiac output. Anesth. Analg. 117(2), 366-372( 2013
    • (2013) Anesth. Analg , vol.117 , Issue.2 , pp. 366-372
    • Bubenek-Turconi, S.I.1    Craciun, M.2    Miclea, I.3    Perel, A.4
  • 92
    • 84861121516 scopus 로고    scopus 로고
    • Comparison of noninvasive continuous arterial waveform analysis (nexfin) with transthoracic doppler echocardiography for monitoring of cardiac output
    • van Der Spoel AG, Voogel AJ, Folkers A, Boer C, Bouwman RA. Comparison of noninvasive continuous arterial waveform analysis (Nexfin) with transthoracic Doppler echocardiography for monitoring of cardiac output. J. Clin. Anesth. 24(4), 304-309( 2012
    • (2012) J. Clin. Anesth , vol.24 , Issue.4 , pp. 304-309
    • Van Der Spoel, A.G.1    Voogel, A.J.2    Folkers, A.3    Boer, C.4    Bouwman, R.A.5
  • 94
    • 0034783835 scopus 로고    scopus 로고
    • Comparison of bioimpedance versus thermodilution cardiac output during cardiac surgery: Evaluation of a second-generation bioimpedance device
    • Spiess BD, Patel MA, Soltow LO, Wright IH. Comparison of bioimpedance versus thermodilution cardiac output during cardiac surgery: Evaluation of a second-generation bioimpedance device. J. Cardiothorac. Vasc. Anesth. 15(5), 567-573 (2001
    • (2001) J. Cardiothorac. Vasc. Anesth , vol.15 , Issue.5 , pp. 567-573
    • Spiess, B.D.1    Patel, M.A.2    Soltow, L.O.3    Wright, I.H.4
  • 95
    • 0030477530 scopus 로고    scopus 로고
    • Standardization of non-invasive impedance cardiography for assessment of stroke volume: Comparison with thermodilution
    • Woltjer HH, Bogaard HJ, Scheffer GJ, van Der Spoel HI, Huybregts MA, De Vries PM. Standardization of non-invasive impedance cardiography for assessment of stroke volume: Comparison with thermodilution. Br. J. Anaesth. 77(6), 748-752 (1996
    • (1996) Br. J. Anaesth , vol.77 , Issue.6 , pp. 748-752
    • Woltjer, H.H.1    Bogaard, H.J.2    Scheffer, G.J.3    Van Der Spoel, H.I.4    Huybregts, M.A.5    De Vries, P.M.6
  • 96
    • 0001575491 scopus 로고    scopus 로고
    • Comparison of cardiac output measurements by teb vs intermettent bolus thermodilution in mechanical ventilated patients american college of chest physicians
    • Ziegler D, Grotti L. Comparison of cardiac output measurements by TEB vs Intermettent bolus thermodilution in mechanical ventilated patients. American college of chest physicians. Chest 116(4) (Suppl. 2), 281S (1999
    • (1999) Chest , vol.116 , Issue.4 SUPPL. 2
    • Ziegler, D.1    Grotti, L.2
  • 97
    • 0036171177 scopus 로고    scopus 로고
    • Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery
    • Sageman WS, Riffenburgh RH, Spiess BD. Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery. J. Cardiothorac. Vasc. Anesth. 16(1), 8-14 (2002
    • (2002) J. Cardiothorac. Vasc. Anesth , vol.16 , Issue.1 , pp. 8-14
    • Sageman, W.S.1    Riffenburgh, R.H.2    Spiess, B.D.3
  • 98
    • 8644266685 scopus 로고    scopus 로고
    • Equivalence of the bioimpedance and thermodilution methods in measuring cardiac output in hospitalized patients with advanced, decompensated chronic heart failure
    • Albert NM, Hail MD, Li J, Young JB. Equivalence of the bioimpedance and thermodilution methods in measuring cardiac output in hospitalized patients with advanced, decompensated chronic heart failure. Am. J. Crit. Care. 13(6), 469-479( 2004
    • (2004) Am. J. Crit. Care , vol.13 , Issue.6 , pp. 469-479
    • Albert, N.M.1    Hail, M.D.2    Li, J.3    Young, J.B.4
  • 99
    • 67650388551 scopus 로고    scopus 로고
    • Correlation of impedance cardiography with invasive hemodynamic measurements in patients with advanced heart failure: The bioimpedance cardiography (big) substudy of the evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness (escape) trial
    • Kamath SA, Drazner MH, Tasissa G, Rogers JG, Stevenson LW, Yancy CW. Correlation of impedance cardiography with invasive hemodynamic measurements in patients with advanced heart failure: The BioImpedance CardioGraphy (BIG) substudy of the Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness (ESCAPE) Trial. Am. Heart J. 158(2), 217-223 (2009
    • (2009) Am. Heart J. , vol.158 , Issue.2 , pp. 217-223
    • Kamath, S.A.1    Drazner, M.H.2    Tasissa, G.3    Rogers, J.G.4    Stevenson, L.W.5    Yancy, C.W.6
  • 100
    • 80755140164 scopus 로고    scopus 로고
    • Value of impedance cardiography in patients studied for pulmonary hypertension
    • Tonelli AR, Alnuaimat H, Li N, Carrie R, Mubarak KK. Value of impedance cardiography in patients studied for pulmonary hypertension. Lung 189(5), 369-375 (2011
    • (2011) Lung , vol.189 , Issue.5 , pp. 369-375
    • Tonelli, A.R.1    Alnuaimat, H.2    Li, N.3    Carrie, R.4    Mubarak, K.K.5
  • 101
    • 77956059573 scopus 로고    scopus 로고
    • Impedance cardiography versus invasive measurements of stroke volume index in patients with chronic heart failure
    • Kieback AG, Borges AC, Schink T, Baumann G, Laule M. Impedance cardiography versus invasive measurements of stroke volume index in patients with chronic heart failure. Int. J. Cardiol. 143(2), 211-213 (2010
    • (2010) Int. J. Cardiol , vol.143 , Issue.2 , pp. 211-213
    • Kieback, A.G.1    Borges, A.C.2    Schink, T.3    Baumann, G.4    Laule, M.5
  • 102
    • 27744604582 scopus 로고    scopus 로고
    • Comparison of electrical velocimetry and transoesophageal doppler echocardiography for measuring stroke volume and cardiac output
    • Schmidt C, Theilmeier G, Van Aken H et al. Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output. Br. J. Anaesth. 95(5), 603-610 (2005
    • (2005) Br. J. Anaesth , vol.95 , Issue.5 , pp. 603-610
    • Schmidt, C.1    Theilmeier, G.2    Van Aken, H.3
  • 103
    • 0032978532 scopus 로고    scopus 로고
    • Noninvasive measurement of cardiac output: Two methods compared in patients with mitral regurgitation
    • van Der Meer NJ, Vonk Noordegraaf A, Kamp O, De Vries PM. Noninvasive measurement of cardiac output: Two methods compared in patients with mitral regurgitation. Angiology 50(2), 95-101( 1999
    • (1999) Angiology , vol.50 , Issue.2 , pp. 95-101
    • Van Der Meer, N.J.1    Vonk Noordegraaf, A.2    Kamp, O.3    De Vries, P.M.4
  • 104
    • 65349115982 scopus 로고    scopus 로고
    • Noninvasive assessment of cardiac index in healthy volunteers: A comparison between thoracic impedance cardiography and Doppler echocardiography
    • Fellahi JL, Caille V, Charron C, Deschamps-Berger PH, Vieillard-Baron A. Noninvasive assessment of cardiac index in healthy volunteers: A comparison between thoracic impedance cardiography and Doppler echocardiography. Anesth. Analg. 108(5), 1553-1559 (2009
    • (2009) Anesth. Analg , vol.108 , Issue.5 , pp. 1553-1559
    • Fellahi, J.L.1    Caille, V.2    Charron, C.3    Deschamps-Berger, P.H.4    Vieillard-Baron, A.5
  • 105
    • 84883462652 scopus 로고    scopus 로고
    • Noninvasive cardiac monitoring in pregnancy: Impedance cardiography versus echocardiography
    • Burlingame J, Ohana P, Aaronoff M, Seto T. Noninvasive cardiac monitoring in pregnancy: Impedance cardiography versus echocardiography. J. Perinatol. 33(9), 675-680 (2013
    • (2013) J. Perinatol , vol.33 , Issue.9 , pp. 675-680
    • Burlingame, J.1    Ohana, P.2    Aaronoff, M.3    Seto, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.