메뉴 건너뛰기




Volumn 41, Issue 6, 1997, Pages 708-712

Impedance cardiography in cardiac surgery patients: Abnormal body weight gives unreliable cardiac output measurements

Author keywords

Cardiac output; Impedance cardiography; Obesity; Post cardiac surgery; Thermodilution

Indexed keywords

ADULT; AGED; ARTICLE; BODY WEIGHT; CALCULATION; CLINICAL ARTICLE; DIAGNOSTIC ACCURACY; FEMALE; HEART DISEASE; HEART OUTPUT; HEART STROKE VOLUME; HEART SURGERY; HUMAN; IMPEDANCE CARDIOGRAPHY; MALE; OBESITY; PRIORITY JOURNAL; RELIABILITY; THERMODILUTION;

EID: 0030791347     PISSN: 00015172     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1399-6576.1997.tb04770.x     Document Type: Article
Times cited : (17)

References (23)
  • 1
    • 0013978742 scopus 로고
    • Development and evaluation of an impedance cardiac output system
    • Kubicek WG, Karnegis JN, Patterson RP, et al. Development and evaluation of an impedance cardiac output system. Aerospace Med 1966: 37: 1208-1212.
    • (1966) Aerospace Med , vol.37 , pp. 1208-1212
    • Kubicek, W.G.1    Karnegis, J.N.2    Patterson, R.P.3
  • 2
    • 0001952126 scopus 로고
    • Stroke volume equation with a linear base impedance model and its accuracy as compared to thermodilution and magnetic flowmeter techniques in humans and animals
    • Zadar, Yugoslavia
    • Sramek BB, Rose DM, Miyamoto A. Stroke volume equation with a linear base impedance model and its accuracy as compared to thermodilution and magnetic flowmeter techniques in humans and animals. Proc Sixth Int Conf Elect Bioimpedance, Zadar, Yugoslavia, 1983: 38.
    • (1983) Proc Sixth Int Conf Elect Bioimpedance , pp. 38
    • Sramek, B.B.1    Rose, D.M.2    Miyamoto, A.3
  • 3
    • 0022980897 scopus 로고
    • A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale
    • Bernstein DP. A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale. Crit Care Med 1986: 14: 904-909.
    • (1986) Crit Care Med , vol.14 , pp. 904-909
    • Bernstein, D.P.1
  • 4
    • 0026317931 scopus 로고
    • Non invasive assessment of cardiac output in patients with coronary ischemia
    • Schwade J, Allison RD. Non invasive assessment of cardiac output in patients with coronary ischemia. J Appl Cardiol 1986: 6: 455-471.
    • (1986) J Appl Cardiol , vol.6 , pp. 455-471
    • Schwade, J.1    Allison, R.D.2
  • 5
    • 0024161968 scopus 로고
    • Accuracy of electrical impedance cardiography for measuring cardiac output in children with congenital heart defects
    • Miles DS, Gotshall RW, Golden JC, Tuuri DT, Beekman III RH, Dillon T. Accuracy of electrical impedance cardiography for measuring cardiac output in children with congenital heart defects. Am J Cardiol 1988: 61: 612-616.
    • (1988) Am J Cardiol , vol.61 , pp. 612-616
    • Miles, D.S.1    Gotshall, R.W.2    Golden, J.C.3    Tuuri, D.T.4    Beekman III, R.H.5    Dillon, T.6
  • 6
    • 0025348706 scopus 로고
    • Determination of cardiac output during positive end-expiratory pressure: Non invasive electrical bioimpedance with standard thermodilution
    • Castor G, Molter G, Helms J, Niedermark I, Altmayer P. Determination of cardiac output during positive end-expiratory pressure: Non invasive electrical bioimpedance with standard thermodilution. Crit Care Med 1990: 18: 544-547.
    • (1990) Crit Care Med , vol.18 , pp. 544-547
    • Castor, G.1    Molter, G.2    Helms, J.3    Niedermark, I.4    Altmayer, P.5
  • 7
    • 0022975760 scopus 로고
    • Comparison of cardiac output by bioimpedance and thermodilution in severely ill surgical patients
    • Appel PL, Kram HB, Mackabee J, Flemming EW, Shoemaker WC. Comparison of cardiac output by bioimpedance and thermodilution in severely ill surgical patients. Crit Care Med 1986: 14: 933-935.
    • (1986) Crit Care Med , vol.14 , pp. 933-935
    • Appel, P.L.1    Kram, H.B.2    Mackabee, J.3    Flemming, E.W.4    Shoemaker, W.C.5
  • 8
    • 0023787022 scopus 로고
    • Comparison of cardiac output estimation by thoracic electrical bioimpedance, thermodilution, and Fick methods
    • Salandin V, Zussa C, Risica G, et al. Comparison of cardiac output estimation by thoracic electrical bioimpedance, thermodilution, and Fick methods. Crit Care Med 1988: 16: 1157-1158.
    • (1988) Crit Care Med , vol.16 , pp. 1157-1158
    • Salandin, V.1    Zussa, C.2    Risica, G.3
  • 9
    • 85047677424 scopus 로고
    • Reproducibility of hemodynamic measurements by impedance cardiography
    • Veigl VL, Judy W. Reproducibility of hemodynamic measurements by impedance cardiography. Cardiovasc Res 1983: 17: 728-734.
    • (1983) Cardiovasc Res , vol.17 , pp. 728-734
    • Veigl, V.L.1    Judy, W.2
  • 10
    • 0023736370 scopus 로고
    • Use of transthoracic bioimpedance to determine cardiac output in pediatric patients
    • Introna RPS, Pruet JK, Crumrine RC, Cuadrado AR. Use of transthoracic bioimpedance to determine cardiac output in pediatric patients. Crit Care Med 1988: 16: 1101-1105.
    • (1988) Crit Care Med , vol.16 , pp. 1101-1105
    • Introna, R.P.S.1    Pruet, J.K.2    Crumrine, R.C.3    Cuadrado, A.R.4
  • 11
    • 0027458319 scopus 로고
    • Comparison of thoracic electrical bioimpedance and thermodilution for the measurement of cardiac index in patients with severe sepsis
    • Young JD, McQuillan P. Comparison of thoracic electrical bioimpedance and thermodilution for the measurement of cardiac index in patients with severe sepsis. Br J Anaesth 1993: 70: 58-62.
    • (1993) Br J Anaesth , vol.70 , pp. 58-62
    • Young, J.D.1    McQuillan, P.2
  • 12
    • 0024364123 scopus 로고
    • Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation
    • Preiser JC, Daper A, Parquier JN, Contempré B, Vincent JL. Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation. Intensive Care Med 1989: 15: 221-223.
    • (1989) Intensive Care Med , vol.15 , pp. 221-223
    • Preiser, J.C.1    Daper, A.2    Parquier, J.N.3    Contempré, B.4    Vincent, J.L.5
  • 13
    • 0023864184 scopus 로고
    • Non invasive assessment of cardiac output by impedance cardiography: Disagreement between two equations to estimate stroke volume
    • DeMey C, Enterling D. Non invasive assessment of cardiac output by impedance cardiography: disagreement between two equations to estimate stroke volume. Aviat Space Environ Med 1988: 59: 57-62.
    • (1988) Aviat Space Environ Med , vol.59 , pp. 57-62
    • DeMey, C.1    Enterling, D.2
  • 14
    • 0026639782 scopus 로고
    • The validity of cardiac output measurement by thoracic impedance: A meta-analysis
    • Fuller HD. The validity of cardiac output measurement by thoracic impedance: a meta-analysis. Clin Invest Med 1982: 15: 103-112.
    • (1982) Clin Invest Med , vol.15 , pp. 103-112
    • Fuller, H.D.1
  • 15
    • 0017756202 scopus 로고
    • Evaluation of impedance cardiography during anesthesia in extremely obese patients
    • Rasmussen JP, Eriksen J, Andersen J. Evaluation of impedance cardiography during anesthesia in extremely obese patients. Acta Anaesthesiol Scand 1977: 21: 342-346.
    • (1977) Acta Anaesthesiol Scand , vol.21 , pp. 342-346
    • Rasmussen, J.P.1    Eriksen, J.2    Andersen, J.3
  • 16
    • 0019976011 scopus 로고
    • Borderline hypertension and obesity: Two prehypertensive states with elevated cardiac output
    • Messerli FH, Ventura HO, Reisin E, et al. Borderline hypertension and obesity: two prehypertensive states with elevated cardiac output. Circulation 1982: 66: 55-60.
    • (1982) Circulation , vol.66 , pp. 55-60
    • Messerli, F.H.1    Ventura, H.O.2    Reisin, E.3
  • 18
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986: 1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 0017700829 scopus 로고
    • Prediction of normal blood volume: Relation of blood volume to body habitus
    • Feldschuh J, Enson Y. Prediction of normal blood volume: relation of blood volume to body habitus. Circulation 1977: 56: 605-609.
    • (1977) Circulation , vol.56 , pp. 605-609
    • Feldschuh, J.1    Enson, Y.2
  • 20
    • 84948010813 scopus 로고
    • Obesity and essential hypertension: Hemodynamics, intravascular volume and plasma renin activity
    • Messerli FH, Christie B, DeCarvalho JGR, et al. Obesity and essential hypertension: hemodynamics, intravascular volume and plasma renin activity. Arch Intern Med 1981: 141: 81-85.
    • (1981) Arch Intern Med , vol.141 , pp. 81-85
    • Messerli, F.H.1    Christie, B.2    DeCarvalho, J.G.R.3
  • 21
    • 0025166460 scopus 로고
    • Non invasive versus invasive assessment of cardiac output after cardiac surgery: Clinical validation
    • Spahn DR, Schmid ER, Tornic M, et al. Non invasive versus invasive assessment of cardiac output after cardiac surgery: Clinical validation. J Cardiothoracic Anaesth 1990: 4: 46-59.
    • (1990) J Cardiothoracic Anaesth , vol.4 , pp. 46-59
    • Spahn, D.R.1    Schmid, E.R.2    Tornic, M.3
  • 22
    • 0025786660 scopus 로고
    • Bioimpedance versus thermodilution cardiac output measurement: The Bomed NCCOM3 after coronary bypass surgery
    • Thomas AN, Ryan J, Doran BRH, Pollard BJ. Bioimpedance versus thermodilution cardiac output measurement: the Bomed NCCOM3 after coronary bypass surgery. Intensive Care Med 1991: 17: 383-386.
    • (1991) Intensive Care Med , vol.17 , pp. 383-386
    • Thomas, A.N.1    Ryan, J.2    Doran, B.R.H.3    Pollard, B.J.4
  • 23
    • 0023894669 scopus 로고
    • Comparison of bioimpedance and thermodilution methods for determining cardiac output: Experimental and clinical studies
    • Spinale FG, Reines HD, Crawford FA. Comparison of bioimpedance and thermodilution methods for determining cardiac output: Experimental and clinical studies. Ann Thoracic Surg 1988: 45: 421-425.
    • (1988) Ann Thoracic Surg , vol.45 , pp. 421-425
    • Spinale, F.G.1    Reines, H.D.2    Crawford, F.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.