메뉴 건너뛰기




Volumn 12, Issue 11, 2010, Pages 921-928

Continuous glucose monitoring in subjects with type 1 diabetes: Improvement in accuracy by correcting for background current

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AMPEROMETRIC BIOSENSOR; AMPEROMETRY; ARTICLE; BLOOD GLUCOSE MONITORING; CALIBRATION; CLINICAL ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; HUMAN; HYPERGLYCEMIA; HYPOGLYCEMIA; INSULIN DEPENDENT DIABETES MELLITUS; INTERMETHOD COMPARISON; MATHEMATICAL ANALYSIS; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; VALIDATION STUDY;

EID: 78649344157     PISSN: 15209156     EISSN: None     Source Type: Journal    
DOI: 10.1089/dia.2010.0020     Document Type: Article
Times cited : (14)

References (28)
  • 1
    • 78649374766 scopus 로고    scopus 로고
    • U.S. Food and Drug Administration accessed July 16 2010
    • U.S. Food and Drug Administration: http://www.fda.gov/MedicalDevices/ ProductsandMedicalProcedures/Device ApprovalsandClearances/Recently- ApprovedDevices/ucm 074293.htm (accessed July 16, 2010).
  • 3
    • 0242363717 scopus 로고    scopus 로고
    • A continuous glucose sensor based on wired enzyme technology\results from a 3-day trial in patients with type 1 diabetes
    • Feldman B, Brazg R, Schwartz S, Weinstein R: A continuous glucose sensor based on wired enzyme technology\results from a 3-day trial in patients with type 1 diabetes. Diabetes Technol Ther 2003;5:769-779.
    • (2003) Diabetes Technol Ther , vol.5 , pp. 769-779
    • Feldman, B.1    Brazg, R.2    Schwartz, S.3    Weinstein, R.4
  • 4
    • 0036015960 scopus 로고    scopus 로고
    • Calibrationofasubcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 2. Superiority of the one-point calibration method
    • Choleau C, Klein JC, Reach G, Aussedat B, Demaria-Pesce V, Wilson GS, GiffordR,Ward WK: Calibrationofasubcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 2. Superiority of the one-point calibration method. Biosens Bioelectron 2002;17:647-654.
    • (2002) Biosens Bioelectron , vol.17 , pp. 647-654
    • Choleau, C.1    Klein, J.C.2    Reach, G.3    Aussedat, B.4    Demaria-Pesce, V.5    Wilson, G.S.6    Giffordrward, W.K.7
  • 5
    • 0036015959 scopus 로고    scopus 로고
    • Calibration of a subcutaneous amperometric glucose sensor. Part 1. Effect of measurement uncertainties on the determination of sensor sensitivity and background current
    • Choleau C, Klein JC, Reach G, Aussedat B, Demaria-Pesce V, Wilson GS, Gifford R, Ward WK: Calibration of a subcutaneous amperometric glucose sensor. Part 1. Effect of measurement uncertainties on the determination of sensor sensitivity and background current. Biosens Bioelectron 2002;17:641-646.
    • (2002) Biosens Bioelectron , vol.17 , pp. 641-646
    • Choleau, C.1    Klein, J.C.2    Reach, G.3    Aussedat, B.4    Demaria-Pesce, V.5    Wilson, G.S.6    Gifford, R.7    Ward, W.K.8
  • 7
    • 0026597462 scopus 로고
    • Arterial, arterialized venous, venous and capillary blood glucose measurements in normal man during hyperinsulinaemic euglycaemia and hypoglycaemia
    • Liu D, Moberg E, Kollind M, Lins PE, Adamson U, Mac-donald IA: Arterial, arterialized venous, venous and capillary blood glucose measurements in normal man during hyperinsulinaemic euglycaemia and hypoglycaemia. Dia-betologia 1992;35:287-290.
    • (1992) Dia-betologia , vol.35 , pp. 287-290
    • Liu, D.1    Moberg, E.2    Kollind, M.3    Lins, P.E.4    Adamson, U.5    Mac-Donald, I.A.6
  • 8
    • 62249151783 scopus 로고    scopus 로고
    • Graphical and numerical evaluation of continuous glucose sensing time lag
    • Kovatchev BP, Shields D, Breton M: Graphical and numerical evaluation of continuous glucose sensing time lag. Diabetes Technol Ther 2009;11:139-143.
    • (2009) Diabetes Technol Ther , vol.11 , pp. 139-143
    • Kovatchev, B.P.1    Shields, D.2    Breton, M.3
  • 9
    • 0030834435 scopus 로고    scopus 로고
    • Symmetrization of the blood glucose measurement scale and its applications
    • Kovatchev BP, Cox DJ, Gonder-Frederick LA, Clarke W: Symmetrization of the blood glucose measurement scale and its applications. Diabetes Care 1997;20:1655-1658.
    • (1997) Diabetes Care , vol.20 , pp. 1655-1658
    • Kovatchev, B.P.1    Cox, D.J.2    Gonder-Frederick, L.A.3    Clarke, W.4
  • 11
    • 26944476066 scopus 로고    scopus 로고
    • Coil-type implantable glucose biosensor with excess enzyme loading
    • Yu B, Moussy Y, Moussy F: Coil-type implantable glucose biosensor with excess enzyme loading. Front Biosci 2005;10: 512-520.
    • (2005) Front Biosci , vol.10 , pp. 512-520
    • Yu, B.1    Moussy, Y.2    Moussy, F.3
  • 12
    • 0028500479 scopus 로고
    • Use of charged membranes to control interference by body chemicals in a glucose biosensor
    • Vaidya R, Wilkins E: Use of charged membranes to control interference by body chemicals in a glucose biosensor. Med Eng Phys 1994;16:416-421.
    • (1994) Med Eng Phys , vol.16 , pp. 416-421
    • Vaidya, R.1    Wilkins, E.2
  • 13
    • 4344584088 scopus 로고    scopus 로고
    • Chemical polymerization of m-phenylenediamine, in the presence of glucose oxidase, produces an enzyme-retaining electrooxidisable polymer used to produce a biosensor for amperometric detection of glucose from brain dialysate
    • Osborne PG, Hashimoto M: Chemical polymerization of m-phenylenediamine, in the presence of glucose oxidase, produces an enzyme-retaining electrooxidisable polymer used to produce a biosensor for amperometric detection of glucose from brain dialysate. Analyst 2004;129:759-765.
    • (2004) Analyst , vol.129 , pp. 759-765
    • Osborne, P.G.1    Hashimoto, M.2
  • 14
    • 0343729903 scopus 로고    scopus 로고
    • Amperometric glucose sensor based on coimmobilization of glucose oxidase and poly (p-phenylenediamine) at a platinum microdisk electrode
    • Jing-Juan X, Hong-Yuan C: Amperometric glucose sensor based on coimmobilization of glucose oxidase and poly (p-phenylenediamine) at a platinum microdisk electrode. Anal Biochem 2000;280:221-226.
    • (2000) Anal Biochem , vol.280 , pp. 221-226
    • Jing-Juan, X.1    Hong-Yuan, C.2
  • 15
    • 0037462122 scopus 로고    scopus 로고
    • Long tethers binding redox centers to polymer backbones enhance electron transport in enzyme "wiring" hydrogels
    • Mao F, Mano N, Heller A: Long tethers binding redox centers to polymer backbones enhance electron transport in enzyme "Wiring" hydrogels. J Am Chem Soc 2003;125:4951-4957.
    • (2003) J Am Chem Soc , vol.125 , pp. 4951-4957
    • Mao, F.1    Mano, N.2    Heller, A.3
  • 18
    • 54749134550 scopus 로고    scopus 로고
    • Continuous glucose sensors: Continuing questions about clinical accuracy
    • Clarke WL, Kovatchev B: Continuous glucose sensors: continuing questions about clinical accuracy. J Diabetes Sci Technol 2007;1:669-675.
    • (2007) J Diabetes Sci Technol , vol.1 , pp. 669-675
    • Clarke, W.L.1    Kovatchev, B.2
  • 19
    • 34047167073 scopus 로고    scopus 로고
    • A dual-rate Kalman filter for continuous glucose monitoring. Conf Proc
    • Kuure-Kinsey M, Palerm CC, Bequette BW: A dual-rate Kalman filter for continuous glucose monitoring. Conf Proc IEEE Eng Med Biol Soc 2006;1:63-66.
    • (2006) IEEE Eng Med Biol Soc , vol.1 , pp. 63-66
    • Kuure-Kinsey, M.1    Palerm, C.C.2    Bequette, B.W.3
  • 21
    • 0035715516 scopus 로고    scopus 로고
    • Determination of time delay between blood and interstitial adipose tissue glucose concentration change by microdialysis in healthy volunteers
    • Wientjes KJ, Schoonen AJ: Determination of time delay between blood and interstitial adipose tissue glucose concentration change by microdialysis in healthy volunteers. Int J Artif Organs 2001;24:884-889.
    • (2001) Int J Artif Organs , vol.24 , pp. 884-889
    • Wientjes, K.J.1    Schoonen, A.J.2
  • 22
    • 70449688342 scopus 로고    scopus 로고
    • Analysis of time lags and other sources of error of the DexCom SEVEN continuous glucose monitor
    • Kamath A, Mahalingam A, Brauker J: Analysis of time lags and other sources of error of the DexCom SEVEN continuous glucose monitor. Diabetes Technol Ther 2009;11:689-695.
    • (2009) Diabetes Technol Ther , vol.11 , pp. 689-695
    • Kamath, A.1    Mahalingam, A.2    Brauker, J.3
  • 23
    • 77953066924 scopus 로고    scopus 로고
    • Delays in minimally invasive continuous glucose monitoring devices: A review of current technology
    • Keenan DB, Mastrototaro JJ, Voskanyan G, Steil GM: Delays in minimally invasive continuous glucose monitoring devices: a review of current technology. J Diabetes Sci Technol 2009;3:1207-1214.
    • (2009) J Diabetes Sci Technol , vol.3 , pp. 1207-1214
    • Keenan, D.B.1    Mastrototaro, J.J.2    Voskanyan, G.3    Steil, G.M.4
  • 24
    • 77955504672 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Real-time algorithms for calibration, filtering, and alarms
    • Bequette BW: Continuous glucose monitoring: real-time algorithms for calibration, filtering, and alarms. J Diabetes Sci Technol 2010;4:404-418.
    • (2010) J Diabetes Sci Technol , vol.4 , pp. 404-418
    • Bequette, B.W.1
  • 26
    • 0037278431 scopus 로고    scopus 로고
    • Determination of plasma glucose during rapid glucose excursions with a subcutaneous glucose sensor
    • Steil GM, Rebrin K, Mastrototaro J, Bernaba B, Saad MF: Determination of plasma glucose during rapid glucose excursions with a subcutaneous glucose sensor. Diabetes Technol Ther 2003;5:27-31.
    • (2003) Diabetes Technol Ther , vol.5 , pp. 27-31
    • Steil, G.M.1    Rebrin, K.2    Mastrototaro, J.3    Bernaba, B.4    Saad, M.F.5
  • 28
    • 0032836714 scopus 로고    scopus 로고
    • Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring
    • Rebrin K, Steil GM, van Antwerp WP, Mastrototaro JJ: Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. Am J Physiol 1999;277:E561-E571.
    • (1999) Am J Physiol , vol.277
    • Rebrin, K.1    Steil, G.M.2    Van Antwerp, W.P.3    Mastrototaro, J.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.