Enhanced accuracy of continuous glucose monitoring by online extended kalman filtering

Author keywords

[No Author keywords available]

Indexed keywords

GLUCOSE;

EID: 77951129243     PISSN: 15209156     EISSN: None     Source Type: Journal    
DOI: 10.1089/dia.2009.0158     Document Type: Article
Times cited : (62)

References (28)
  • 1
    • 34248138343 scopus 로고    scopus 로고
    • The need for performance standards for continuous glucose monitors
    • Nichols JH, Klonoff DC: The need for performance standards for continuous glucose monitors. J Diabetes Sci Technol 2007;1:92-95.
    • (2007) J Diabetes Sci Technol , vol.1 , pp. 92-95
    • Nichols, J.H.1    Klonoff, D.C.2
  • 2
    • 54749111511 scopus 로고    scopus 로고
    • Minimally-invasive and non-invasive continuous glucose monitoring systems: Indications, advantages, limitations and clinical aspects
    • De Block C, Vertommen J, Manuel-y-Keenoy B, Van Gaal L: Minimally-invasive and non-invasive continuous glucose monitoring systems: indications, advantages, limitations and clinical aspects. Curr Diabetes Rev 2008;4:159-168.
    • (2008) Curr Diabetes Rev , vol.4 , pp. 159-168
    • De Block, C.1    Vertommen, J.2    Manuel-Y-Keenoy, B.3    Van Gaal, L.4
  • 4
    • 18144421498 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Roadmap for 21st century diabetes therapy
    • Klonoff DC: Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care 2005;28:1231-1239.
    • (2005) Diabetes Care , vol.28 , pp. 1231-1239
    • Klonoff, D.C.1
  • 5
    • 54749108405 scopus 로고    scopus 로고
    • Clinical use of real-time continuous glucose monitoring
    • Battelino T, Bolinder J: Clinical use of real-time continuous glucose monitoring. Curr Diabetes Rev 2008;4:218-222.
    • (2008) Curr Diabetes Rev , vol.4 , pp. 218-222
    • Battelino, T.1    Bolinder, J.2
  • 6
    • 77649120539 scopus 로고    scopus 로고
    • inventors; Dex- Com Inc. assignee, Publication Number WO=2008=042918; April 10, 2008. International Application Number PCT=US2007= 080228; October 4
    • Simpson P, Brister M, Wightlin M, Pryor J, inventors; Dex- Com, Inc., assignee: Dual electrode system for a continuous analyte sensor. Publication Number WO=2008=042918; April 10, 2008. International Application Number PCT=US2007= 080228; October 4, 2007.
    • (2007) Dual Electrode System for A Continuous Analyte Sensor
    • Simpson, P.1    Brister, M.2    Wightlin, M.3    Pryor, J.4
  • 9
    • 3342981187 scopus 로고    scopus 로고
    • Evaluating the accuracy of continuous glucose-monitoring sensors: Continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data
    • Kovatchev BP, Gonder-Frederick LA, Cox DJ, Clarke WL: Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data. Diabetes Care 2004;27:1922-1928.
    • (2004) Diabetes Care , vol.27 , pp. 1922-1928
    • Kovatchev, B.P.1    Gonder-Frederick, L.A.2    Cox, D.J.3    Clarke, W.L.4
  • 10
    • 0032836714 scopus 로고    scopus 로고
    • Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring
    • Rebrin K, Steil GM, van Antwerp WP: Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. Am J Physiol 1999;277:E561-E571.
    • (1999) Am J Physiol , vol.277
    • Rebrin, K.1    Steil, G.M.2    Van Antwerp, W.P.3
  • 11
    • 14844348734 scopus 로고    scopus 로고
    • The extended Kalman filter for continuous glucose monitoring
    • Knobbe EJ, Buckingham B: The extended Kalman filter for continuous glucose monitoring. Diabetes Technol Ther 2005; 7:15-27.
    • (2005) Diabetes Technol Ther , vol.7 , pp. 15-27
    • Knobbe, E.J.1    Buckingham, B.2
  • 13
    • 69949146908 scopus 로고    scopus 로고
    • In silico preclinical trials: A proof of concept in closed-loop control of type 1 diabetes
    • Kovatchev BP, Breton M, Dalla Man C, Cobelli C: In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes. J Diabetes Sci Technol 2009;3:44-55.
    • (2009) J Diabetes Sci Technol , vol.3 , pp. 44-55
    • Kovatchev, B.P.1    Breton, M.2    Dalla Man, C.3    Cobelli, C.4
  • 15
    • 77649133392 scopus 로고    scopus 로고
    • Reconstruction of glucose in plasma from interstitial fluid continuous glucose monitoring data: Role of sensor calibration
    • Facchinetti A, Sparacino G, Cobelli C: Reconstruction of glucose in plasma from interstitial fluid continuous glucose monitoring data: role of sensor calibration. J Diabetes Sci Technol 2007;1:617-623.
    • (2007) J Diabetes Sci Technol , vol.1 , pp. 617-623
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3
  • 16
    • 73949126778 scopus 로고    scopus 로고
    • Analysis, modeling, and simulation of the accuracy of continuous glucose sensors
    • Breton M, Kovatchev BP: Analysis, modeling, and simulation of the accuracy of continuous glucose sensors. J Diabetes Sci Technol 2008;2:853-862.
    • (2008) J Diabetes Sci Technol , vol.2 , pp. 853-862
    • Breton, M.1    Kovatchev, B.P.2
  • 17
    • 59649089217 scopus 로고    scopus 로고
    • Modeling of calibration effectiveness and blood-tointerstitial glucose dynamics as potential confounders of the accuracy of continuous glucose sensors during hyperinsulinemic clamp
    • King C, Anderson SM, Breton M, Clarke WL, Kovatchev BP: Modeling of calibration effectiveness and blood-tointerstitial glucose dynamics as potential confounders of the accuracy of continuous glucose sensors during hyperinsulinemic clamp. J Diabetes Sci Technol 2007;1:317-322.
    • (2007) J Diabetes Sci Technol , vol.1 , pp. 317-322
    • King, C.1    Anderson, S.M.2    Breton, M.3    Clarke, W.L.4    Kovatchev, B.P.5
  • 18
    • 2142728611 scopus 로고    scopus 로고
    • Continuous glucose monitoring with glucose sensors: Calibration and assessment criteria
    • Glucose Monitoring Study Group
    • Lodwig V, Heinemann L; Glucose Monitoring Study Group: Continuous glucose monitoring with glucose sensors: calibration and assessment criteria. Diabetes Technol Ther 2003;5:572-586.
    • (2003) Diabetes Technol Ther , vol.5 , pp. 572-586
    • Lodwig, V.1    Heinemann, L.2
  • 21
    • 34548829642 scopus 로고    scopus 로고
    • Meal simulation model of the glucose-insulin system
    • Dalla Man C, Rizza RA, Cobelli C: Meal simulation model of the glucose-insulin system. IEEE Trans Biomed Eng 2007;54: 1740-1749.
    • (2007) IEEE Trans Biomed Eng , vol.54 , pp. 1740-1749
    • Dalla Man, C.1    Rizza, R.A.2    Cobelli, C.3
  • 22
    • 31144461926 scopus 로고    scopus 로고
    • Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: Mathematical methods and clinical application
    • Kovatchev BP, Clarke WL, Breton M, Brayman K, McCall A: Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: mathematical methods and clinical application. Diabetes Technol Ther 2005;7:849-862.
    • (2005) Diabetes Technol Ther , vol.7 , pp. 849-862
    • Kovatchev, B.P.1    Clarke, W.L.2    Breton, M.3    Brayman, K.4    McCall, A.5
  • 24
    • 0031130574 scopus 로고    scopus 로고
    • Nonparametric input estimation in physiological systems: Problems, methods and case study
    • De Nicolao G, Sparacino G, Cobelli C: Nonparametric input estimation in physiological systems: problems, methods and case study. Automatica 1997;33:851-870.
    • (1997) Automatica , vol.33 , pp. 851-870
    • De Nicolao, G.1    Sparacino, G.2    Cobelli, C.3
  • 26
    • 77951102569 scopus 로고    scopus 로고
    • accessed April 1, 2009
    • http:==glucosecontrol.ucsd.edu (accessed April 1, 2009).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.