메뉴 건너뛰기




Volumn 34, Issue 6, 2011, Pages

Increasing the low-glucose alarm of a continuous glucose monitoring system prevents exercise-induced hypoglycemia without triggering any false alarms

Author keywords

[No Author keywords available]

Indexed keywords

CARBOHYDRATE DERIVATIVE; HEMOGLOBIN A1C; INSULIN;

EID: 80052002951     PISSN: 01495992     EISSN: 19355548     Source Type: Journal    
DOI: 10.2337/dc10-2243     Document Type: Letter
Times cited : (14)

References (5)
  • 1
    • 79952995521 scopus 로고    scopus 로고
    • Effect of short-term use of a continuous glucose monitoring system with a real-time glucose display and a low glucose alarm on incidence and duration of hypoglycaemia in a home setting in type 1 diabetes mellitus
    • Davey R.J., Jones T.W., Fournier P.A. Effect of short-term use of a continuous glucose monitoring system with a real-time glucose display and a low glucose alarm on incidence and duration of hypoglycaemia in a home setting in type 1 diabetes mellitus. J Diabetes Sci Technol 2010;4:1457-1464
    • (2010) J Diabetes Sci Technol , vol.4 , pp. 1457-1464
    • Davey, R.J.1    Jones, T.W.2    Fournier, P.A.3
  • 3
    • 0242300559 scopus 로고    scopus 로고
    • Timing of Changes in Interstitial and Venous Blood Glucose Measured with a Continuous Subcutaneous Glucose Sensor
    • DOI 10.2337/diabetes.52.11.2790
    • Boyne M.S., Silver D.M., Kaplan J., Saudek C.D. Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. Diabetes 2003;52:2790-2794 (Pubitemid 37339709)
    • (2003) Diabetes , vol.52 , Issue.11 , pp. 2790-2794
    • Boyne, M.S.1    Silver, D.M.2    Kaplan, J.3    Saudek, C.D.4
  • 4
    • 79953009960 scopus 로고    scopus 로고
    • The contribution of an intrinsic lag of CGMS to differences in measured and actual glucose concentrations changing at variable rates in vitro
    • Davey R.J., Low C.Y., Fournier P.A. The contribution of an intrinsic lag of CGMS to differences in measured and actual glucose concentrations changing at variable rates in vitro. J Diabetes Sci Technol 2010;4:1393-1399
    • (2010) J Diabetes Sci Technol , vol.4 , pp. 1393-1399
    • Davey, R.J.1    Low, C.Y.2    Fournier, P.A.3
  • 5
    • 19944387338 scopus 로고    scopus 로고
    • The decline in blood glucose levels is less with intermittent high-intensity compared with moderate exercise in individuals with type 1 diabetes
    • DOI 10.2337/diacare.28.6.1289
    • Guelfi K.J., Jones T.W., Fournier P.A. The decline in blood glucose levels is less with intermittent high-intensity compared with moderate exercise in individuals with type 1 diabetes. Diabetes Care 2005;28:1289-1294 (Pubitemid 40756687)
    • (2005) Diabetes Care , vol.28 , Issue.6 , pp. 1289-1294
    • Guelfi, K.J.1    Jones, T.W.2    Fournier, P.A.3