메뉴 건너뛰기




Volumn 29, Issue 8, 2013, Pages 851-858

Effect of CNC-milling on the marginal and internal fit of dental ceramics: A pilot study

Author keywords

CAD CAM; Dental ceramics; Internal fit; Marginal fit; Three dimensional analysis

Indexed keywords

CAD/CAMS; DENTAL CERAMIC; INTERNAL FIT; MARGINAL FIT; THREE-DIMENSIONAL ANALYSIS;

EID: 84880736310     PISSN: 01095641     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.dental.2013.04.018     Document Type: Article
Times cited : (39)

References (32)
  • 1
    • 84355161961 scopus 로고    scopus 로고
    • The future of dental devices is digital
    • R. van Noort The future of dental devices is digital Dental Materials 28 2012 3 12
    • (2012) Dental Materials , vol.28 , pp. 3-12
    • Van Noort, R.1
  • 2
    • 63449088303 scopus 로고    scopus 로고
    • A review of dental CAD/CAM: Current status and future perspectives from 20 years of experience
    • T. Miyazaki, Y. Hotta, J. Kunii, S. Kuriyama, and Y. Tamaki A review of dental CAD/CAM: current status and future perspectives from 20 years of experience Dental Materials Journal 28 2009 44 56
    • (2009) Dental Materials Journal , vol.28 , pp. 44-56
    • Miyazaki, T.1    Hotta, Y.2    Kunii, J.3    Kuriyama, S.4    Tamaki, Y.5
  • 3
    • 9944229063 scopus 로고    scopus 로고
    • Contemporary materials and technologies for all-ceramic fixed partial dentures: A review of the literature
    • DOI 10.1016/j.prosdent.2004.09.015, PII S0022391304006158
    • A.J. Raigrodski Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature Journal of Prosthetic Dentistry 92 2004 557 562 (Pubitemid 39593586)
    • (2004) Journal of Prosthetic Dentistry , vol.92 , Issue.6 , pp. 557-562
    • Raigrodski, A.J.1
  • 4
    • 33744813282 scopus 로고    scopus 로고
    • Influence of cavity preparation design on fracture resistance of posterior Leucite-reinforced ceramic restorations
    • DOI 10.1016/j.prosdent.2006.03.022, PII S0022391306001880
    • C.J. Soares, L.R.M. Martins, R.B. Fonseca, L. Correr-Sobrinho, and A.J. Fernandes Neto Influence of cavity preparation design on fracture resistance of posterior leucite-reinforced ceramic restorations Journal of Prosthetic Dentistry 95 2006 421 429 (Pubitemid 43831081)
    • (2006) Journal of Prosthetic Dentistry , vol.95 , Issue.6 , pp. 421-429
    • Soares, C.J.1    Martins, L.R.M.2    Fonseca, R.B.3    Correr-Sobrinho, L.4    Fernandes Neto, A.J.5
  • 5
    • 0037828938 scopus 로고    scopus 로고
    • Biaxial flexural strength, elastic moduli, and x-ray diffraction characterization of three pressable all-ceramic materials
    • DOI 10.1067/mpr.2003.42
    • M. Albakry, M. Guazzato, and M.V. Swain Biaxial flexural strength, elastic moduli, and X-ray diffraction characterization of three pressable all-ceramic materials Journal of Prosthetic Dentistry 89 2003 374 380 (Pubitemid 37323893)
    • (2003) Journal of Prosthetic Dentistry , vol.89 , Issue.4 , pp. 374-380
    • Albakry, M.1    Guazzato, M.2    Swain, M.V.3
  • 6
    • 84863779101 scopus 로고    scopus 로고
    • Machining variability impacts on the strength of a "chair-side" CAD-CAM ceramic
    • O. Addison, X. Cao, P. Sunnar, and G.J.P. Fleming Machining variability impacts on the strength of a "chair-side" CAD-CAM ceramic Dental Materials 28 2012 880 887
    • (2012) Dental Materials , vol.28 , pp. 880-887
    • Addison, O.1    Cao, X.2    Sunnar, P.3    Fleming, G.J.P.4
  • 7
    • 80054709246 scopus 로고    scopus 로고
    • Marginal gap, internal fit, and fracture load of leucite-reinforced ceramic inlays fabricated by CEREC inLab and hot-pressed techniques
    • A. Keshvad, T. Hooshmand, F. Asefzadeh, F. Khalilinejad, M. Alihemmati, and R. van Noort Marginal gap, internal fit, and fracture load of leucite-reinforced ceramic inlays fabricated by CEREC inLab and hot-pressed techniques Journal of Prosthodontics 20 2011 535 540
    • (2011) Journal of Prosthodontics , vol.20 , pp. 535-540
    • Keshvad, A.1    Hooshmand, T.2    Asefzadeh, F.3    Khalilinejad, F.4    Alihemmati, M.5    Van Noort, R.6
  • 8
    • 0036133921 scopus 로고    scopus 로고
    • Interface gap size of manually and CAD/CAM-manufactured ceramic inlays/onlays in vitro
    • DOI 10.1016/S0300-5712(01)00059-8, PII S0300571201000598
    • S. Addi, A. Hedayati-Khams, A. Poya, and G. Sjögren Interface gap size of manually and CAD/CAM-manufactured ceramic inlays/onlays in vitro Journal of Dentistry 30 2002 53 58 (Pubitemid 40433461)
    • (2002) Journal of Dentistry , vol.30 , Issue.1 , pp. 53-58
    • Addi, S.1    Hedayati-Khams, A.2    Poya, A.3    Sjogren, G.4
  • 9
    • 77957292587 scopus 로고    scopus 로고
    • Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system
    • M.R. Baig, K.B.-C. Tan, and J.I. Nicholls Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system Journal of Prosthetic Dentistry 104 2010 216 227
    • (2010) Journal of Prosthetic Dentistry , vol.104 , pp. 216-227
    • Baig, M.R.1    Tan, K.B.-C.2    Nicholls, J.I.3
  • 10
    • 78049284330 scopus 로고    scopus 로고
    • Evaluation of the marginal integrity of ceramic copings with different marginal angles using two different CAD/CAM systems
    • S. Giannetopoulos, R. van Noort, and E. Tsitrou Evaluation of the marginal integrity of ceramic copings with different marginal angles using two different CAD/CAM systems Journal of Dentistry 38 2010 980 986
    • (2010) Journal of Dentistry , vol.38 , pp. 980-986
    • Giannetopoulos, S.1    Van Noort, R.2    Tsitrou, E.3
  • 11
    • 34047251477 scopus 로고    scopus 로고
    • A comparison of the accuracy of fit of 2 methods for fabricating implant-prosthodontic frameworks
    • S.A. Al-Fadda, G.A. Zarb, and Y. Finer A comparison of the accuracy of fit of 2 methods for fabricating implant-prosthodontic frameworks International Journal of Prosthodontics 20 2007 125 131
    • (2007) International Journal of Prosthodontics , vol.20 , pp. 125-131
    • Al-Fadda, S.A.1    Zarb, G.A.2    Finer, Y.3
  • 13
    • 84857065097 scopus 로고    scopus 로고
    • Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: A three-dimensional analysis of accuracy and reproducibility
    • O. Schäfer, D.C. Watts, B.W. Sigusch, H. Kuepper, and A. Guentsch Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: a three-dimensional analysis of accuracy and reproducibility Dental Materials 28 2012 320 326
    • (2012) Dental Materials , vol.28 , pp. 320-326
    • Schäfer, O.1    Watts, D.C.2    Sigusch, B.W.3    Kuepper, H.4    Guentsch, A.5
  • 14
    • 84880741448 scopus 로고    scopus 로고
    • American National Standards Institute/American Dental Association Chicago
    • American National Standards Institute/American Dental Association Dental elastomeric impression materials 2003 American National Standards Institute/American Dental Association Chicago
    • (2003) Dental Elastomeric Impression Materials
  • 15
    • 20444364152 scopus 로고    scopus 로고
    • Accuracy of newly formulated fast-setting elastomeric impression materials
    • DOI 10.1016/j.prosdent.2005.03.007, PII S0022391305001605
    • C.P.K. Wadhwani, G.H. Johnson, X. Lepe, and A.J. Raigrodski Accuracy of newly formulated fast-setting elastomeric impression materials Journal of Prosthetic Dentistry 93 2005 530 539 (Pubitemid 40798342)
    • (2005) Journal of Prosthetic Dentistry , vol.93 , Issue.6 , pp. 530-539
    • Wadhwani, C.P.K.1    Johnson, G.H.2    Lepe, X.3    Raigrodski, A.J.4
  • 16
    • 0021508448 scopus 로고
    • Dimensional stability of elastomeric impression materials in custom-made and stock trays
    • J. Valderhaug, and F. Fløystrand Dimensional stability of elastomeric impression materials in custom-made and stock trays Journal of Prosthetic Dentistry 52 1984 514 517
    • (1984) Journal of Prosthetic Dentistry , vol.52 , pp. 514-517
    • Valderhaug, J.1    Fløystrand, F.2
  • 17
  • 18
    • 84880719568 scopus 로고    scopus 로고
    • Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials
    • [Epub ahead]
    • H. Rudolph, S. Quaas, M. Haim, J. Preißler, M.H. Walter, and R. Koch Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials Clinical Oral Investigations 2012 [Epub ahead]
    • (2012) Clinical Oral Investigations
    • Rudolph, H.1    Quaas, S.2    Haim, M.3    Preißler, J.4    Walter, M.H.5    Koch, R.6
  • 19
    • 84865735500 scopus 로고    scopus 로고
    • Qualitative and quantitative three-dimensional accuracy of a single tooth captured by elastomeric impression materials: An in vitro study
    • O. Schäfer, M. Schmidt, R. Goebel, and H. Kuepper Qualitative and quantitative three-dimensional accuracy of a single tooth captured by elastomeric impression materials: an in vitro study Journal of Prosthetic Dentistry 108 2012 165 172
    • (2012) Journal of Prosthetic Dentistry , vol.108 , pp. 165-172
    • Schäfer, O.1    Schmidt, M.2    Goebel, R.3    Kuepper, H.4
  • 21
    • 10444286626 scopus 로고    scopus 로고
    • An innovative method for evaluation of the 3-D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing
    • R.G. Luthardt, G. Bornemann, S. Lemelson, M.H. Walter, and A. Hüls An innovative method for evaluation of the 3-D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing International Journal of Prosthodontics 17 2004 680 685 (Pubitemid 39643276)
    • (2004) International Journal of Prosthodontics , vol.17 , Issue.6 , pp. 680-685
    • Luthardt, R.G.1    Bornemann, G.2    Lemelson, S.3    Walter, M.H.4    Huls, A.5
  • 22
    • 46249120193 scopus 로고    scopus 로고
    • Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems
    • K.-B. Lee, C.-W. Park, K.-H. Kim, and T.-Y. Kwon Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems Dental Materials Journal 27 2008 422 426
    • (2008) Dental Materials Journal , vol.27 , pp. 422-426
    • Lee, K.-B.1    Park, C.-W.2    Kim, K.-H.3    Kwon, T.-Y.4
  • 23
    • 56849121618 scopus 로고    scopus 로고
    • Marginal fit of heat-pressed vs. CAD/CAM processed all-ceramic onlays using a milling unit prototype
    • S. Reich, S. Gozdowski, L. Trentzsch, R. Frankenberger, and U. Lohbauer Marginal fit of heat-pressed vs. CAD/CAM processed all-ceramic onlays using a milling unit prototype Operative Dentistry 33 2008 644 650
    • (2008) Operative Dentistry , vol.33 , pp. 644-650
    • Reich, S.1    Gozdowski, S.2    Trentzsch, L.3    Frankenberger, R.4    Lohbauer, U.5
  • 26
    • 84863848999 scopus 로고    scopus 로고
    • Internal and marginal adaptation of pressable and computer-aided design/computer-assisted manufacture onlay restorations
    • B.A. Vanlioglu, B. Evren, C. Yildiz, A. Uludamar, and Y.K. Ozkan Internal and marginal adaptation of pressable and computer-aided design/computer- assisted manufacture onlay restorations International Journal of Prosthodontics 25 2012 262 264
    • (2012) International Journal of Prosthodontics , vol.25 , pp. 262-264
    • Vanlioglu, B.A.1    Evren, B.2    Yildiz, C.3    Uludamar, A.4    Ozkan, Y.K.5
  • 27
    • 0033628733 scopus 로고    scopus 로고
    • Determination of the minimum number of marginal gap measurements required for practical in-vitro testing
    • M. Groten, D. Axmann, L. Pröbster, and H. Weber Determination of the minimum number of marginal gap measurements required for practical in-vitro testing Journal of Prosthetic Dentistry 83 2000 40 49
    • (2000) Journal of Prosthetic Dentistry , vol.83 , pp. 40-49
    • Groten, M.1    Axmann, D.2    Pröbster, L.3    Weber, H.4
  • 29
    • 38949176674 scopus 로고    scopus 로고
    • In vitro rapid intraoral adjustment of porcelain prostheses using a high-speed dental handpiece
    • DOI 10.1016/j.actbio.2007.08.006, PII S1742706107001274
    • X.-F. Song, L. Yin, Y.-G. Han, and H. Wang In vitro rapid intraoral adjustment of porcelain prostheses using a high-speed dental handpiece Acta Biomaterialia 4 2008 414 424 (Pubitemid 351218093)
    • (2008) Acta Biomaterialia , vol.4 , Issue.2 , pp. 414-424
    • Song, X.-F.1    Yin, L.2    Han, Y.-G.3    Wang, H.4
  • 30
    • 0032064142 scopus 로고    scopus 로고
    • Effect of mixing technique on surface characteristics of impression materials
    • X. Lepe, G.H. Johnson, J.C. Berg, and T.C. Aw Effect of mixing technique on surface characteristics of impression materials Journal of Prosthetic Dentistry 79 1998 495 502
    • (1998) Journal of Prosthetic Dentistry , vol.79 , pp. 495-502
    • Lepe, X.1    Johnson, G.H.2    Berg, J.C.3    Aw, T.C.4
  • 31
    • 84873578014 scopus 로고    scopus 로고
    • Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision
    • A. Ender, and A. Mehl Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision Journal of Prosthetic Dentistry 109 2013 121 128
    • (2013) Journal of Prosthetic Dentistry , vol.109 , pp. 121-128
    • Ender, A.1    Mehl, A.2
  • 32
    • 79954438032 scopus 로고    scopus 로고
    • Full arch scans: Conventional versus digital impressions - An in-vitro study
    • A. Ender, and A. Mehl Full arch scans: conventional versus digital impressions - an in-vitro study International Journal of Computerized Dentistry 14 2011 11 21
    • (2011) International Journal of Computerized Dentistry , vol.14 , pp. 11-21
    • Ender, A.1    Mehl, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.