메뉴 건너뛰기




Volumn 17, Issue 1, 2013, Pages

Bench-to-bedside review: Functional hemodynamics during surgery - should it be used for all high-risk cases?

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL SURGERY; AIRWAY PRESSURE; BLEEDING; BREATHING RATE; CARDIOVASCULAR RISK; CENTRAL VENOUS PRESSURE; CLINICAL PRACTICE; CRITICALLY ILL PATIENT; HEART HEMODYNAMICS; HEART OUTPUT; HEART RHYTHM; HEART RIGHT VENTRICLE FAILURE; HEART STROKE VOLUME; HUMAN; HYPERVOLEMIA; INTRAVENOUS ADMINISTRATION; PERIOPERATIVE PERIOD; PLETHYSMOGRAPHY; PREDICTION; PRIORITY JOURNAL; PULSE PRESSURE; REVIEW; SURGERY; SYSTOLIC BLOOD PRESSURE; TREATMENT RESPONSE; ARTIFICIAL VENTILATION; BLOOD PRESSURE; FLUID THERAPY; HEMODYNAMICS; PEROPERATIVE CARE; PHYSIOLOGIC MONITORING; SYSTOLE; TIDAL VOLUME;

EID: 84873283397     PISSN: 13648535     EISSN: 1466609X     Source Type: Journal    
DOI: 10.1186/cc11448     Document Type: Review
Times cited : (34)

References (81)
  • 1
    • 54749118597 scopus 로고    scopus 로고
    • A rational approach to perioperative fluid management
    • 10.1097/ALN.0b013e3181863117, 18813052
    • Chappell D, Jacob M, Hofmann-Kiefer K, Conzen P, Rehm M. A rational approach to perioperative fluid management. Anesthesiology 2008, 109:723-740. 10.1097/ALN.0b013e3181863117, 18813052.
    • (2008) Anesthesiology , vol.109 , pp. 723-740
    • Chappell, D.1    Jacob, M.2    Hofmann-Kiefer, K.3    Conzen, P.4    Rehm, M.5
  • 2
    • 79958110885 scopus 로고    scopus 로고
    • A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients
    • 10.1213/ANE.0b013e3181eeaae5, 20966436
    • Hamilton MA, Cecconi M, Rhodes A. A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients. Anesth Analg 2011, 112:1392-1402. 10.1213/ANE.0b013e3181eeaae5, 20966436.
    • (2011) Anesth Analg , vol.112 , pp. 1392-1402
    • Hamilton, M.A.1    Cecconi, M.2    Rhodes, A.3
  • 3
    • 79958113679 scopus 로고    scopus 로고
    • Maintaining tissue perfusion in high-risk surgical patients: a systematic review of randomized clinical trials
    • 10.1213/ANE.0b013e3182055384, 21156979
    • Gurgel ST, Do Nascimento P. Maintaining tissue perfusion in high-risk surgical patients: a systematic review of randomized clinical trials. Anesth Analg 2011, 112:1384-1391. 10.1213/ANE.0b013e3182055384, 21156979.
    • (2011) Anesth Analg , vol.112 , pp. 1384-1391
    • Gurgel, S.T.1    Do Nascimento, P.2
  • 4
    • 84873300613 scopus 로고    scopus 로고
    • CardioQ-ODM Quick Reference Guide for the OR
    • CardioQ-ODM Quick Reference Guide for the OR. , http://www. deltexmedical.com/downloads/clinicaleducationguides/CQ_OR_QRG9051_5309_3.pdf
  • 5
    • 80055085490 scopus 로고    scopus 로고
    • Pleth variability index to predict fluid responsiveness in colorectal surgery
    • 10.1213/ANE.0b013e31822c10cd, 21965349
    • Hood JA, Wilson RJT. Pleth variability index to predict fluid responsiveness in colorectal surgery. Anesth Analg 2011, 113:1058-1063. 10.1213/ANE.0b013e31822c10cd, 21965349.
    • (2011) Anesth Analg , vol.113 , pp. 1058-1063
    • Hood, J.A.1    Wilson, R.J.T.2
  • 6
    • 33845321475 scopus 로고    scopus 로고
    • Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial [ISRCTN38797445]
    • 10.1186/cc3887, 1414018, 16356219
    • Pearse R, Dawson D, Fawcett J, Rhodes A, Grounds RM, Bennett ED. Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial [ISRCTN38797445]. Crit Care 2005, 9:R687-R693. 10.1186/cc3887, 1414018, 16356219.
    • (2005) Crit Care , vol.9
    • Pearse, R.1    Dawson, D.2    Fawcett, J.3    Rhodes, A.4    Grounds, R.M.5    Bennett, E.D.6
  • 7
    • 79957547490 scopus 로고    scopus 로고
    • Goal-directed haemodynamic therapy during elective total hip arthroplasty under regional anaesthesia
    • 10.1186/cc10246, 3218998, 21624138
    • Cecconi M, Fasano N, Langiano N, Divella M, Costa MG, Rhodes A, Rocca Della G. Goal-directed haemodynamic therapy during elective total hip arthroplasty under regional anaesthesia. Crit Care 2011, 15:R132. 10.1186/cc10246, 3218998, 21624138.
    • (2011) Crit Care , vol.15
    • Cecconi, M.1    Fasano, N.2    Langiano, N.3    Divella, M.4    Costa, M.G.5    Rhodes, A.6    Rocca Della, G.7
  • 8
    • 33749045716 scopus 로고    scopus 로고
    • Intravascular fluid administration and hemodynamic performance during open abdominal surgery
    • 10.1213/01.ane.0000226092.48770.fe, 16931679
    • Svensén CH, Olsson J, Hahn RG. Intravascular fluid administration and hemodynamic performance during open abdominal surgery. Anesth Analg 2006, 103:671-676. 10.1213/01.ane.0000226092.48770.fe, 16931679.
    • (2006) Anesth Analg , vol.103 , pp. 671-676
    • Svensén, C.H.1    Olsson, J.2    Hahn, R.G.3
  • 9
    • 33847048638 scopus 로고    scopus 로고
    • Current practice of hemodynamic monitoring and vasopressor and inotropic therapy in post-operative cardiac surgery patients in Germany: results from a postal survey
    • 10.1111/j.1399-6576.2006.01190.x, 17096667
    • Kastrup M, Markewitz A, Spies C, Carl M, Erb J, Grosse J, Schirmer U. Current practice of hemodynamic monitoring and vasopressor and inotropic therapy in post-operative cardiac surgery patients in Germany: results from a postal survey. Acta Anaesthesiol Scand 2007, 51:347-358. 10.1111/j.1399-6576.2006.01190.x, 17096667.
    • (2007) Acta Anaesthesiol Scand , vol.51 , pp. 347-358
    • Kastrup, M.1    Markewitz, A.2    Spies, C.3    Carl, M.4    Erb, J.5    Grosse, J.6    Schirmer, U.7
  • 10
    • 80051578300 scopus 로고    scopus 로고
    • Hemodynamic monitoring and management in patients undergoing high risk surgery: a survey among North American and European anesthesiologists
    • 10.1186/cc10364, 3387639, 21843353
    • Cannesson M, Pestel G, Ricks C, Hoeft A, Perel A. Hemodynamic monitoring and management in patients undergoing high risk surgery: a survey among North American and European anesthesiologists. Crit Care 2011, 15:R197. 10.1186/cc10364, 3387639, 21843353.
    • (2011) Crit Care , vol.15
    • Cannesson, M.1    Pestel, G.2    Ricks, C.3    Hoeft, A.4    Perel, A.5
  • 11
    • 0036283553 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence
    • 10.1378/chest.121.6.2000, 12065368
    • Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 2002, 121:2000-2008. 10.1378/chest.121.6.2000, 12065368.
    • (2002) Chest , vol.121 , pp. 2000-2008
    • Michard, F.1    Teboul, J.L.2
  • 12
    • 47549096309 scopus 로고    scopus 로고
    • Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the Tale of Seven Mares
    • 10.1378/chest.07-2331, 18628220
    • Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the Tale of Seven Mares. Chest 2008, 134:172-178. 10.1378/chest.07-2331, 18628220.
    • (2008) Chest , vol.134 , pp. 172-178
    • Marik, P.E.1    Baram, M.2    Vahid, B.3
  • 13
    • 0028084525 scopus 로고
    • A comparison of systolic blood pressure variations and echocardiographic estimates of end-diastolic left ventricular size in patients after aortic surgery
    • Coriat P, Vrillon M, Perel A, Baron JF, Le Bret F, Saada M, Viars P. A comparison of systolic blood pressure variations and echocardiographic estimates of end-diastolic left ventricular size in patients after aortic surgery. Anesth Analg 1994, 78:46-53.
    • (1994) Anesth Analg , vol.78 , pp. 46-53
    • Coriat, P.1    Vrillon, M.2    Perel, A.3    Baron, J.F.4    Le Bret, F.5    Saada, M.6    Viars, P.7
  • 14
    • 0032437998 scopus 로고    scopus 로고
    • Systolic pressure variation as a guide to fluid therapy in patients with sepsisinduced hypotension
    • 10.1097/00000542-199812000-00007, 9856704
    • Tavernier B, Makhotine O, Lebuff e G, Dupont J, Scherpereel P. Systolic pressure variation as a guide to fluid therapy in patients with sepsisinduced hypotension. Anesthesiology 1998, 89:1313-1321. 10.1097/00000542-199812000-00007, 9856704.
    • (1998) Anesthesiology , vol.89 , pp. 1313-1321
    • Tavernier, B.1    Makhotine, O.2    Lebuffe, G.3    Dupont, J.4    Scherpereel, P.5
  • 15
    • 28844464011 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators
    • 10.1093/bja/aei262, 16286349
    • Preisman S, Kogan S, Berkenstadt H, Perel A. Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators. Br J Anaesth 2005, 95:746-755. 10.1093/bja/aei262, 16286349.
    • (2005) Br J Anaesth , vol.95 , pp. 746-755
    • Preisman, S.1    Kogan, S.2    Berkenstadt, H.3    Perel, A.4
  • 16
    • 69349089330 scopus 로고    scopus 로고
    • Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature
    • 10.1097/CCM.0b013e3181a590da, 19602972
    • Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 2009, 37:2642-2647. 10.1097/CCM.0b013e3181a590da, 19602972.
    • (2009) Crit Care Med , vol.37 , pp. 2642-2647
    • Marik, P.E.1    Cavallazzi, R.2    Vasu, T.3    Hirani, A.4
  • 17
    • 34548453111 scopus 로고    scopus 로고
    • Volume responsiveness
    • 10.1097/MCC.0b013e3282ec68b2, 17762234
    • Monnet X, Teboul J-L. Volume responsiveness. Curr Opin Crit Care 2007, 13:549-553. 10.1097/MCC.0b013e3282ec68b2, 17762234.
    • (2007) Curr Opin Crit Care , vol.13 , pp. 549-553
    • Monnet, X.1    Teboul, J.-L.2
  • 18
    • 0032420373 scopus 로고    scopus 로고
    • Assessing fluid responsiveness by the systolic pressure variation in mechanically ventilated patients
    • 10.1097/00000542-199812000-00005, 9856702
    • Perel A. Assessing fluid responsiveness by the systolic pressure variation in mechanically ventilated patients. Anesthesiology 1998, 89:1309-1310. 10.1097/00000542-199812000-00005, 9856702.
    • (1998) Anesthesiology , vol.89 , pp. 1309-1310
    • Perel, A.1
  • 19
    • 79957656409 scopus 로고    scopus 로고
    • Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine
    • 10.1097/CCM.0b013e31820edcf0, 21336124
    • Monnet X, Letierce A, Hamzaoui O, Chemla D, Anguel N, Osman D, Richard C, Teboul J-L. Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine. Crit Care Med 2011, 39:1394-1399. 10.1097/CCM.0b013e31820edcf0, 21336124.
    • (2011) Crit Care Med , vol.39 , pp. 1394-1399
    • Monnet, X.1    Letierce, A.2    Hamzaoui, O.3    Chemla, D.4    Anguel, N.5    Osman, D.6    Richard, C.7    Teboul, J.-L.8
  • 21
    • 79955628982 scopus 로고    scopus 로고
    • What is a fluid challenge?
    • 10.1097/MCC.0b013e32834699cd, 21508838
    • Cecconi M, Parsons AK, Rhodes A. What is a fluid challenge?. Curr Opin Crit Care 2011, 17:290-295. 10.1097/MCC.0b013e32834699cd, 21508838.
    • (2011) Curr Opin Crit Care , vol.17 , pp. 290-295
    • Cecconi, M.1    Parsons, A.K.2    Rhodes, A.3
  • 22
    • 17044389841 scopus 로고    scopus 로고
    • The physiological basis of arterial pressure variation during positive-pressure ventilation
    • Perel A. The physiological basis of arterial pressure variation during positive-pressure ventilation. Réanimation 2005, 14:162-171.
    • (2005) Réanimation , vol.14 , pp. 162-171
    • Perel, A.1
  • 23
    • 23044461875 scopus 로고    scopus 로고
    • Changes in arterial pressure during mechanical ventilation
    • 10.1097/00000542-200508000-00026, 16052125
    • Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology 2005, 103:419-428. 10.1097/00000542-200508000-00026, 16052125.
    • (2005) Anesthesiology , vol.103 , pp. 419-428
    • Michard, F.1
  • 26
    • 0141817973 scopus 로고    scopus 로고
    • Cyclic changes in arterial pulse during respiratory support revisited by Doppler echocardiography
    • 10.1164/rccm.200301-135OC, 12869360
    • Vieillard-Baron A, Chergui K, Augarde R, Prin S, Page B, Beauchet A, Jardin F. Cyclic changes in arterial pulse during respiratory support revisited by Doppler echocardiography. Am J Respir Crit Care Med 2003, 168:671-676. 10.1164/rccm.200301-135OC, 12869360.
    • (2003) Am J Respir Crit Care Med , vol.168 , pp. 671-676
    • Vieillard-Baron, A.1    Chergui, K.2    Augarde, R.3    Prin, S.4    Page, B.5    Beauchet, A.6    Jardin, F.7
  • 27
    • 78650537612 scopus 로고    scopus 로고
    • Further cautions for the use of ventilatory-induced changes in arterial pressures to predict volume responsiveness
    • 10.1186/cc9223, 3219239, 20920155
    • Magder S. Further cautions for the use of ventilatory-induced changes in arterial pressures to predict volume responsiveness. Crit Care 2010, 14:197. 10.1186/cc9223, 3219239, 20920155.
    • (2010) Crit Care , vol.14 , pp. 197
    • Magder, S.1
  • 28
    • 0023605206 scopus 로고
    • Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage
    • 10.1097/00000542-198710000-00009, 3310740
    • Perel A, Pizov R, Cotev S. Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology 1987, 67:498-502. 10.1097/00000542-198710000-00009, 3310740.
    • (1987) Anesthesiology , vol.67 , pp. 498-502
    • Perel, A.1    Pizov, R.2    Cotev, S.3
  • 29
    • 0942298849 scopus 로고    scopus 로고
    • Systolic pressure variation (Deltadown) can guide fluid therapy during pheochromocytoma surgery
    • 10.1007/BF03018362, 14656776
    • Mallat J, Pironkov A, Destandau M-S, Tavernier B. Systolic pressure variation (Deltadown) can guide fluid therapy during pheochromocytoma surgery. Can J Anaesth 2003, 50:998-1003. 10.1007/BF03018362, 14656776.
    • (2003) Can J Anaesth , vol.50 , pp. 998-1003
    • Mallat, J.1    Pironkov, A.2    Destandau, M.-S.3    Tavernier, B.4
  • 30
    • 38949217780 scopus 로고    scopus 로고
    • Delta down compared with delta pulse pressure as an indicator of volaemia during intracranial surgery
    • 10.1093/bja/aem361, 18083787
    • Deflandre E, Bonhomme V, Hans P. Delta down compared with delta pulse pressure as an indicator of volaemia during intracranial surgery. Br J Anaesth 2007, 100:245-250. 10.1093/bja/aem361, 18083787.
    • (2007) Br J Anaesth , vol.100 , pp. 245-250
    • Deflandre, E.1    Bonhomme, V.2    Hans, P.3
  • 31
    • 0032953278 scopus 로고    scopus 로고
    • Pulse oximetry plethysmographic waveform during changes in blood volume
    • 10.1093/bja/82.2.178, 10364990
    • Shamir M, Eidelman LA, Floman Y, Kaplan L, Pizov R. Pulse oximetry plethysmographic waveform during changes in blood volume. Br J Anaesth 1999, 82:178-181. 10.1093/bja/82.2.178, 10364990.
    • (1999) Br J Anaesth , vol.82 , pp. 178-181
    • Shamir, M.1    Eidelman, L.A.2    Floman, Y.3    Kaplan, L.4    Pizov, R.5
  • 32
    • 0025697098 scopus 로고
    • The use of systolic pressure variation in hemodynamic monitoring during deliberate hypotension in spine surgery
    • 10.1016/0952-8180(90)90061-7, 2346658
    • Pizov R, Segal E, Kaplan L, Floman Y, Perel A. The use of systolic pressure variation in hemodynamic monitoring during deliberate hypotension in spine surgery. J Clin Anesth 1990, 2:96-100. 10.1016/0952-8180(90)90061-7, 2346658.
    • (1990) J Clin Anesth , vol.2 , pp. 96-100
    • Pizov, R.1    Segal, E.2    Kaplan, L.3    Floman, Y.4    Perel, A.5
  • 34
    • 84863002680 scopus 로고    scopus 로고
    • The ability of anesthesia providers to visually estimate systolic pressure variability using the 'eyeball' technique
    • 10.1213/ANE.0b013e31824d5fa1, 22467895
    • Thiele RH, Colquhoun DA, Blum FE, Durieux ME. The ability of anesthesia providers to visually estimate systolic pressure variability using the 'eyeball' technique. Anesth Analg 2012, 115:176-181. 10.1213/ANE.0b013e31824d5fa1, 22467895.
    • (2012) Anesth Analg , vol.115 , pp. 176-181
    • Thiele, R.H.1    Colquhoun, D.A.2    Blum, F.E.3    Durieux, M.E.4
  • 35
    • 84865128498 scopus 로고    scopus 로고
    • Visual estimation of pulse pressure variation is not reliable: a randomized simulation study
    • 10.1007/s10877-012-9359-8, 22491961
    • Rinehart J, Islam T, Boud R, Nguyen A, Alexander B, Canales C, Cannesson M. Visual estimation of pulse pressure variation is not reliable: a randomized simulation study. J Clin Monit Comput 2012, 26:191-196. 10.1007/s10877-012-9359-8, 22491961.
    • (2012) J Clin Monit Comput , vol.26 , pp. 191-196
    • Rinehart, J.1    Islam, T.2    Boud, R.3    Nguyen, A.4    Alexander, B.5    Canales, C.6    Cannesson, M.7
  • 37
    • 19944404764 scopus 로고    scopus 로고
    • Pulse pressure and stroke volume variations during severe haemorrhage in ventilated dogs
    • 10.1093/bja/aei116, 15769736
    • Berkenstadt H, Friedman Z, Preisman S, Keidan I, Livingstone D, Perel A. Pulse pressure and stroke volume variations during severe haemorrhage in ventilated dogs. Br J Anaesth 2005, 94:721-726. 10.1093/bja/aei116, 15769736.
    • (2005) Br J Anaesth , vol.94 , pp. 721-726
    • Berkenstadt, H.1    Friedman, Z.2    Preisman, S.3    Keidan, I.4    Livingstone, D.5    Perel, A.6
  • 38
    • 34948905567 scopus 로고    scopus 로고
    • Pulse pressure variation: beyond the fluid management of patients with shock
    • 10.1186/cc5905, 2206397, 17521454
    • Michard F, Lopes MR, Auler JOC. Pulse pressure variation: beyond the fluid management of patients with shock. Crit Care 2007, 11:131. 10.1186/cc5905, 2206397, 17521454.
    • (2007) Crit Care , vol.11 , pp. 131
    • Michard, F.1    Lopes, M.R.2    Auler, J.O.C.3
  • 39
    • 34948909129 scopus 로고    scopus 로고
    • Goaldirected fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial
    • 10.1186/cc6117, 2556743, 17822565
    • Lopes MR, Oliveira MA, Pereira VOS, Lemos IPB, Auler JOC, Michard F. Goaldirected fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial. Crit Care 2007, 11:R100. 10.1186/cc6117, 2556743, 17822565.
    • (2007) Crit Care , vol.11
    • Lopes, M.R.1    Oliveira, M.A.2    Pereira, V.O.S.3    Lemos, I.P.B.4    Auler, J.O.C.5    Michard, F.6
  • 40
    • 68049133165 scopus 로고    scopus 로고
    • Evaluation of the pulse pressure variation index as a predictor of fluid responsiveness during orthotopic liver transplantation
    • 10.1093/bja/aep123, 19454548
    • Gouvea G, Diaz R, Auler L, Toledo R, Martinho JM. Evaluation of the pulse pressure variation index as a predictor of fluid responsiveness during orthotopic liver transplantation. Br J Anaesth 2009, 103:238-243. 10.1093/bja/aep123, 19454548.
    • (2009) Br J Anaesth , vol.103 , pp. 238-243
    • Gouvea, G.1    Diaz, R.2    Auler, L.3    Toledo, R.4    Martinho, J.M.5
  • 41
    • 8744275421 scopus 로고    scopus 로고
    • Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery
    • 10.1378/chest.126.5.1563, 15539728
    • Kramer A, Zygun D, Hawes H, Easton P, Ferland A. Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery. Chest 2004, 126:1563-1568. 10.1378/chest.126.5.1563, 15539728.
    • (2004) Chest , vol.126 , pp. 1563-1568
    • Kramer, A.1    Zygun, D.2    Hawes, H.3    Easton, P.4    Ferland, A.5
  • 42
    • 41049087999 scopus 로고    scopus 로고
    • Assessment of fluid-responsiveness parameters for off-pump coronary artery bypass surgery: a comparison among LiDCO, transesophageal echochardiography, and pulmonary artery catheter
    • 10.1053/j.jvca.2007.07.007, 18375327
    • Belloni L, Pisano A, Natale A, Piccirillo MR, Piazza L, Ismeno G, De Martino G. Assessment of fluid-responsiveness parameters for off-pump coronary artery bypass surgery: a comparison among LiDCO, transesophageal echochardiography, and pulmonary artery catheter. J Cardiothorac Vasc Anesth 2008, 22:243-248. 10.1053/j.jvca.2007.07.007, 18375327.
    • (2008) J Cardiothorac Vasc Anesth , vol.22 , pp. 243-248
    • Belloni, L.1    Pisano, A.2    Natale, A.3    Piccirillo, M.R.4    Piazza, L.5    Ismeno, G.6    De Martino, G.7
  • 43
    • 41349089777 scopus 로고    scopus 로고
    • Online monitoring of pulse pressure variation to guide fluid therapy after cardiac surgery
    • 10.1213/01.ane.0000287664.03547.c6, 18349193
    • Auler JO, Galas F, Hajjar L, Santos L, Carvalho T, Michard F. Online monitoring of pulse pressure variation to guide fluid therapy after cardiac surgery. Anesth Analg 2008, 106:1201-1206. 10.1213/01.ane.0000287664.03547.c6, 18349193.
    • (2008) Anesth Analg , vol.106 , pp. 1201-1206
    • Auler, J.O.1    Galas, F.2    Hajjar, L.3    Santos, L.4    Carvalho, T.5    Michard, F.6
  • 44
    • 77949403336 scopus 로고    scopus 로고
    • Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery
    • 10.1093/bja/aeq031, 20190260
    • Biais M, Bernard O, Ha JC, Degryse C, Sztark F. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Br J Anaesth 2010, 104:407-413. 10.1093/bja/aeq031, 20190260.
    • (2010) Br J Anaesth , vol.104 , pp. 407-413
    • Biais, M.1    Bernard, O.2    Ha, J.C.3    Degryse, C.4    Sztark, F.5
  • 45
    • 68249101553 scopus 로고    scopus 로고
    • Preload responsiveness is associated with increased interleukin-6 and lower organ yield from brain-dead donors
    • 10.1097/CCM.0b013e3181a960d6, 2864555, 19531941
    • Murugan R, Venkataraman R, Wahed AS, Elder M, Carter M, Madden NJ, Kellum JA. Preload responsiveness is associated with increased interleukin-6 and lower organ yield from brain-dead donors. Crit Care Med 2009, 37:2387-2393. 10.1097/CCM.0b013e3181a960d6, 2864555, 19531941.
    • (2009) Crit Care Med , vol.37 , pp. 2387-2393
    • Murugan, R.1    Venkataraman, R.2    Wahed, A.S.3    Elder, M.4    Carter, M.5    Madden, N.J.6    Kellum, J.A.7
  • 46
    • 80053322000 scopus 로고    scopus 로고
    • Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a 'gray zone' approach
    • 10.1097/ALN.0b013e318225b80a, 21705869
    • Cannesson M, Le Manach Y, Hofer CK, Goarin JP, Lehot J-J, Vallet B, Tavernier B. Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a 'gray zone' approach. Anesthesiology 2011, 115:231-241. 10.1097/ALN.0b013e318225b80a, 21705869.
    • (2011) Anesthesiology , vol.115 , pp. 231-241
    • Cannesson, M.1    Le Manach, Y.2    Hofer, C.K.3    Goarin, J.P.4    Lehot, J.-J.5    Vallet, B.6    Tavernier, B.7
  • 47
    • 0035080242 scopus 로고    scopus 로고
    • Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery
    • Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 2001, 92:984-989.
    • (2001) Anesth Analg , vol.92 , pp. 984-989
    • Berkenstadt, H.1    Margalit, N.2    Hadani, M.3    Friedman, Z.4    Segal, E.5    Villa, Y.6    Perel, A.7
  • 48
    • 0036219991 scopus 로고    scopus 로고
    • Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery
    • 10.1007/s00134-002-1211-z, 11967591
    • Reuter DA, Felbinger TW, Schmidt C, Kilger E, Goedje O, Lamm P, Goetz AE. Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med 2002, 28:392-398. 10.1007/s00134-002-1211-z, 11967591.
    • (2002) Intensive Care Med , vol.28 , pp. 392-398
    • Reuter, D.A.1    Felbinger, T.W.2    Schmidt, C.3    Kilger, E.4    Goedje, O.5    Lamm, P.6    Goetz, A.E.7
  • 49
    • 0037906107 scopus 로고    scopus 로고
    • Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function
    • 10.1097/01.CCM.0000059442.37548.E1, 12771609
    • Reuter DA, Kirchner A, Felbinger TW, Weis FC, Kilger E, Lamm P, Goetz AE. Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function. Crit Care Med 2003, 31:1399-1404. 10.1097/01.CCM.0000059442.37548.E1, 12771609.
    • (2003) Crit Care Med , vol.31 , pp. 1399-1404
    • Reuter, D.A.1    Kirchner, A.2    Felbinger, T.W.3    Weis, F.C.4    Kilger, E.5    Lamm, P.6    Goetz, A.E.7
  • 50
    • 47149111264 scopus 로고    scopus 로고
    • Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system
    • 10.1186/cc6933, 2481481, 18570641
    • Hofer CK, Senn A, Weibel L, Zollinger A. Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system. Crit Care 2008, 12:R82. 10.1186/cc6933, 2481481, 18570641.
    • (2008) Crit Care , vol.12
    • Hofer, C.K.1    Senn, A.2    Weibel, L.3    Zollinger, A.4
  • 51
    • 59649123027 scopus 로고    scopus 로고
    • The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients
    • 10.1213/ane.0b013e318192a36b, 19151280
    • Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Hénaine R, Lehot J-J. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg 2009, 108:513-517. 10.1213/ane.0b013e318192a36b, 19151280.
    • (2009) Anesth Analg , vol.108 , pp. 513-517
    • Cannesson, M.1    Musard, H.2    Desebbe, O.3    Boucau, C.4    Simon, R.5    Hénaine, R.6    Lehot, J.-J.7
  • 52
    • 77953960618 scopus 로고    scopus 로고
    • Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients: a randomized, controlled trial
    • 10.1186/cc8875, 2875533, 20156348
    • Mayer J, Boldt J, Mengistu AM, Röhm KD, Suttner S. Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients: a randomized, controlled trial. Crit Care 2010, 14:R18. 10.1186/cc8875, 2875533, 20156348.
    • (2010) Crit Care , vol.14
    • Mayer, J.1    Boldt, J.2    Mengistu, A.M.3    Röhm, K.D.4    Suttner, S.5
  • 53
    • 64249141041 scopus 로고    scopus 로고
    • Stroke volume variation as a predictor of intravascular volume depression and possible hypotension during the early postoperative period after esophagectomy
    • 10.1245/s10434-008-0139-0, 19219508
    • Kobayashi M, Koh M, Irinoda T, Meguro E, Hayakawa Y, Takagane A. Stroke volume variation as a predictor of intravascular volume depression and possible hypotension during the early postoperative period after esophagectomy. Ann Surg Oncol 2009, 16:1371-1377. 10.1245/s10434-008-0139-0, 19219508.
    • (2009) Ann Surg Oncol , vol.16 , pp. 1371-1377
    • Kobayashi, M.1    Koh, M.2    Irinoda, T.3    Meguro, E.4    Hayakawa, Y.5    Takagane, A.6
  • 54
    • 56449113016 scopus 로고    scopus 로고
    • Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation
    • 10.1093/bja/aen277, 18852114
    • Biais M, Nouette-Gaulain K, Cottenceau V, Revel P, Sztark F. Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth 2008, 101:761-768. 10.1093/bja/aen277, 18852114.
    • (2008) Br J Anaesth , vol.101 , pp. 761-768
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3    Revel, P.4    Sztark, F.5
  • 55
    • 41349123566 scopus 로고    scopus 로고
    • Automated assessment of fluid responsiveness in mechanically ventilated patients
    • 10.1213/ane.0b013e318167abe5, 18349170
    • Perel A. Automated assessment of fluid responsiveness in mechanically ventilated patients. Anesth Analg 2008, 106:1031-1033. 10.1213/ane.0b013e318167abe5, 18349170.
    • (2008) Anesth Analg , vol.106 , pp. 1031-1033
    • Perel, A.1
  • 56
    • 78650941161 scopus 로고    scopus 로고
    • Respiratory variation in pulse pressure and plethysmographic waveforms
    • 10.1213/ANE.0b013e318200366b, 20978246
    • Maguire S, Rinehart J, Vakharia S, Cannesson M. Respiratory variation in pulse pressure and plethysmographic waveforms. Anesth Analg 2011, 112:94-96. 10.1213/ANE.0b013e318200366b, 20978246.
    • (2011) Anesth Analg , vol.112 , pp. 94-96
    • Maguire, S.1    Rinehart, J.2    Vakharia, S.3    Cannesson, M.4
  • 57
    • 77954174190 scopus 로고    scopus 로고
    • Arterial and plethysmographic waveform analysis in anesthetized patients with hypovolemia
    • 10.1097/ALN.0b013e3181da839f, 20526193
    • Pizov R, Eden A, Bystritski D, Kalina E, Tamir A, Gelman S. Arterial and plethysmographic waveform analysis in anesthetized patients with hypovolemia. Anesthesiology 2010, 113:83-91. 10.1097/ALN.0b013e3181da839f, 20526193.
    • (2010) Anesthesiology , vol.113 , pp. 83-91
    • Pizov, R.1    Eden, A.2    Bystritski, D.3    Kalina, E.4    Tamir, A.5    Gelman, S.6
  • 58
    • 47249097004 scopus 로고    scopus 로고
    • Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre
    • 10.1093/bja/aen133, 18522935
    • Cannesson M, Desebbe O, Rosamel P, Delannoy B, Robin J, Bastien O, Lehot JJ. Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre. Br J Anaesth 2008, 101:200-206. 10.1093/bja/aen133, 18522935.
    • (2008) Br J Anaesth , vol.101 , pp. 200-206
    • Cannesson, M.1    Desebbe, O.2    Rosamel, P.3    Delannoy, B.4    Robin, J.5    Bastien, O.6    Lehot, J.J.7
  • 60
    • 34547586336 scopus 로고    scopus 로고
    • Ventilation-induced plethysmographic variations predict fluid responsiveness in ventilated postoperative cardiac surgery patients
    • 10.1213/01.ane.0000267520.16003.17, 17646504
    • Wyffels PAH, Durnez P-J, Helderweirt J, Stockman WMA, De Kegel D. Ventilation-induced plethysmographic variations predict fluid responsiveness in ventilated postoperative cardiac surgery patients. Anesth Analg 2007, 105:448-452. 10.1213/01.ane.0000267520.16003.17, 17646504.
    • (2007) Anesth Analg , vol.105 , pp. 448-452
    • Wyffels, P.A.H.1    Durnez, P.-J.2    Helderweirt, J.3    Stockman, W.M.A.4    De Kegel, D.5
  • 61
    • 77955925229 scopus 로고    scopus 로고
    • Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and metaanalysis of clinical studies
    • 10.1007/s00134-010-1929-y, 20502865
    • Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Maviglia R, Antonelli M. Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and metaanalysis of clinical studies. Intensive Care Med 2010, 36:1475-1483. 10.1007/s00134-010-1929-y, 20502865.
    • (2010) Intensive Care Med , vol.36 , pp. 1475-1483
    • Cavallaro, F.1    Sandroni, C.2    Marano, C.3    La Torre, G.4    Mannocci, A.5    De Waure, C.6    Bello, G.7    Maviglia, R.8    Antonelli, M.9
  • 62
    • 62849122288 scopus 로고    scopus 로고
    • Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients
    • 10.1097/CCM.0b013e3181968fe1, 19237902
    • Monnet X, Osman D, Ridel C, Lamia B, Richard C, Teboul J-L. Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients. Crit Care Med 2009, 37:951-956. 10.1097/CCM.0b013e3181968fe1, 19237902.
    • (2009) Crit Care Med , vol.37 , pp. 951-956
    • Monnet, X.1    Osman, D.2    Ridel, C.3    Lamia, B.4    Richard, C.5    Teboul, J.-L.6
  • 63
    • 84055160934 scopus 로고    scopus 로고
    • Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance
    • 10.1097/CCM.0b013e31822f08d7, 21926581
    • Monnet X, Bleibtreu A, Ferré A, Dres M, Gharbi R, Richard C, Teboul J-L. Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance. Crit Care Med 2012, 40:152-157. 10.1097/CCM.0b013e31822f08d7, 21926581.
    • (2012) Crit Care Med , vol.40 , pp. 152-157
    • Monnet, X.1    Bleibtreu, A.2    Ferré, A.3    Dres, M.4    Gharbi, R.5    Richard, C.6    Teboul, J.-L.7
  • 64
    • 0242637019 scopus 로고    scopus 로고
    • The value of functional hemodynamic parameters in hemodynamic monitoring of ventilated patients
    • Perel A. The value of functional hemodynamic parameters in hemodynamic monitoring of ventilated patients. Anaesthesist 2003, 52:1003-1004.
    • (2003) Anaesthesist , vol.52 , pp. 1003-1004
    • Perel, A.1
  • 65
    • 0024343884 scopus 로고
    • The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs
    • Szold A, Pizov R, Segal E, Perel A. The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs. Intensive Care Med 1989, 15:368-371.
    • (1989) Intensive Care Med , vol.15 , pp. 368-371
    • Szold, A.1    Pizov, R.2    Segal, E.3    Perel, A.4
  • 66
    • 0037352554 scopus 로고    scopus 로고
    • Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients
    • Reuter DA, Bayerlein J, Goepfert MSG, Weis FC, Kilger E, Lamm P, Goetz AE. Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med 2003, 29:476-480.
    • (2003) Intensive Care Med , vol.29 , pp. 476-480
    • Reuter, D.A.1    Bayerlein, J.2    Goepfert, M.S.G.3    Weis, F.C.4    Kilger, E.5    Lamm, P.6    Goetz, A.E.7
  • 67
    • 17444414557 scopus 로고    scopus 로고
    • Pulse pressure variations to predict fluid responsiveness: influence of tidal volume
    • 10.1007/s00134-005-2586-4, 15754196
    • Backer D, Heenen S, Piagnerelli M, Koch M, Vincent J-L. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 2005, 31:517-523. 10.1007/s00134-005-2586-4, 15754196.
    • (2005) Intensive Care Med , vol.31 , pp. 517-523
    • Backer, D.1    Heenen, S.2    Piagnerelli, M.3    Koch, M.4    Vincent, J.-L.5
  • 69
    • 65549167377 scopus 로고    scopus 로고
    • Influence of respiratory rate on stroke volume variation in mechanically ventilated patients
    • 10.1097/ALN.0b013e31819db2a1, 19352152
    • De Backer D, Taccone FS, Holsten R, Ibrahimi F, Vincent JL. Influence of respiratory rate on stroke volume variation in mechanically ventilated patients. Anesthesiology 2009, 110:1092-1097. 10.1097/ALN.0b013e31819db2a1, 19352152.
    • (2009) Anesthesiology , vol.110 , pp. 1092-1097
    • De Backer, D.1    Taccone, F.S.2    Holsten, R.3    Ibrahimi, F.4    Vincent, J.L.5
  • 70
    • 67650401063 scopus 로고    scopus 로고
    • Functional hemodynamics and increased intraabdominal pressure: same thresholds for diff erent conditions ...?
    • 10.1097/CCM.0b013e318194c397, 19325388
    • Malbrain ML, de Laet I. Functional hemodynamics and increased intraabdominal pressure: same thresholds for diff erent conditions ...?. Crit Care Med 2009, 37:781-783. 10.1097/CCM.0b013e318194c397, 19325388.
    • (2009) Crit Care Med , vol.37 , pp. 781-783
    • Malbrain, M.L.1    de Laet, I.2
  • 71
    • 77956230957 scopus 로고    scopus 로고
    • The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension
    • 10.1097/CCM.0b013e3181eb3c21, 20639753
    • Mahjoub Y, Touzeau J, Airapetian N, Lorne E, Hijazi M, Zogheib E, Tinturier F, Slama M, Dupont H. The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension. Crit Care Med 2010, 38:1824-1829. 10.1097/CCM.0b013e3181eb3c21, 20639753.
    • (2010) Crit Care Med , vol.38 , pp. 1824-1829
    • Mahjoub, Y.1    Touzeau, J.2    Airapetian, N.3    Lorne, E.4    Hijazi, M.5    Zogheib, E.6    Tinturier, F.7    Slama, M.8    Dupont, H.9
  • 72
    • 38049182769 scopus 로고    scopus 로고
    • Prediction of volume response under open-chest conditions during coronary artery bypass surgery
    • 10.1186/cc6181, 2246213, 18034888
    • Sander M, Spies CD, Berger K, Grubitzsch H, Foer A, Krämer M, Carl M, Heymann Von C. Prediction of volume response under open-chest conditions during coronary artery bypass surgery. Crit Care 2007, 11:R121. 10.1186/cc6181, 2246213, 18034888.
    • (2007) Crit Care , vol.11
    • Sander, M.1    Spies, C.D.2    Berger, K.3    Grubitzsch, H.4    Foer, A.5    Krämer, M.6    Carl, M.7    Heymann Von, C.8
  • 73
    • 67650346168 scopus 로고    scopus 로고
    • Meaning of pulse pressure variation during cardiac surgery: everything is open
    • 10.1097/CCM.0b013e318194d575, 19325373
    • Teboul J-L. Meaning of pulse pressure variation during cardiac surgery: everything is open. Crit Care Med 2009, 37:757-758. 10.1097/CCM.0b013e318194d575, 19325373.
    • (2009) Crit Care Med , vol.37 , pp. 757-758
    • Teboul, J.-L.1
  • 74
    • 77953589373 scopus 로고    scopus 로고
    • The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery
    • 10.1111/j.1365-2044.2010.06371.x, 20477782
    • Wyffels PAH, Sergeant P, Wouters PF. The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery. Anaesthesia 2010, 65:704-709. 10.1111/j.1365-2044.2010.06371.x, 20477782.
    • (2010) Anaesthesia , vol.65 , pp. 704-709
    • Wyffels, P.A.H.1    Sergeant, P.2    Wouters, P.F.3
  • 75
    • 64149105298 scopus 로고    scopus 로고
    • Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions
    • 10.1097/CCM.0b013e3181958bf7, 19114886
    • De Waal EE, Rex S, Kruitwagen CL, Kalkman CJ, Buhre WF. Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions. Crit Care Med 2009, 37:510-515. 10.1097/CCM.0b013e3181958bf7, 19114886.
    • (2009) Crit Care Med , vol.37 , pp. 510-515
    • De Waal, E.E.1    Rex, S.2    Kruitwagen, C.L.3    Kalkman, C.J.4    Buhre, W.F.5
  • 76
    • 84865117296 scopus 로고    scopus 로고
    • Using non invasive dynamic parameters of fluid responsiveness in children: there is still much to learn
    • 10.1007/s10877-012-9353-1, 22430745
    • Chung E, Cannesson M. Using non invasive dynamic parameters of fluid responsiveness in children: there is still much to learn. J Clin Monit Comput 2012, 26:153-155. 10.1007/s10877-012-9353-1, 22430745.
    • (2012) J Clin Monit Comput , vol.26 , pp. 153-155
    • Chung, E.1    Cannesson, M.2
  • 77
    • 0024600063 scopus 로고
    • The arterial pressure waveform during acute ventricular failure and synchronized external chest compression
    • 10.1213/00000539-198902000-00015, 2643888
    • Pizov R, Ya'ari Y, Perel A. The arterial pressure waveform during acute ventricular failure and synchronized external chest compression. Anesth Analg 1989, 68:150-156. 10.1213/00000539-198902000-00015, 2643888.
    • (1989) Anesth Analg , vol.68 , pp. 150-156
    • Pizov, R.1    Ya'ari, Y.2    Perel, A.3
  • 78
    • 77953533489 scopus 로고    scopus 로고
    • Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study
    • 10.1186/cc9070, 2911766, 20553586
    • Benes J, Chytra I, Altmann P, Hluchy M, Kasal E, Svitak R, Pradl R, Stepan M. Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study. Crit Care 2010, 14:R118. 10.1186/cc9070, 2911766, 20553586.
    • (2010) Crit Care , vol.14
    • Benes, J.1    Chytra, I.2    Altmann, P.3    Hluchy, M.4    Kasal, E.5    Svitak, R.6    Pradl, R.7    Stepan, M.8
  • 79
    • 47249132815 scopus 로고    scopus 로고
    • Influence of systolic-pressure-variation-guided intraoperative fluid management on organ function and oxygen transport
    • 10.1093/bja/aen126, 18511439
    • Buettner M, Schummer W, Huettemann E, Schenke S, van Hout N, Sakka SG. Influence of systolic-pressure-variation-guided intraoperative fluid management on organ function and oxygen transport. Br J Anaesth 2008, 101:194-199. 10.1093/bja/aen126, 18511439.
    • (2008) Br J Anaesth , vol.101 , pp. 194-199
    • Buettner, M.1    Schummer, W.2    Huettemann, E.3    Schenke, S.4    van Hout, N.5    Sakka, S.G.6
  • 80
    • 78149270620 scopus 로고    scopus 로고
    • Conservative vs restrictive individualized goaldirected fluid replacement strategy in major abdominal surgery: a prospective randomized trial
    • 10.1001/archsurg.2010.275, 21173294
    • Futier E, Constantin J-M, Petit A, Chanques G, Kwiatkowski F, Flamein R, Slim K, Sapin V, Jaber S, Bazin J-E. Conservative vs restrictive individualized goaldirected fluid replacement strategy in major abdominal surgery: a prospective randomized trial. Arch Surg 2010, 145:1193-1200. 10.1001/archsurg.2010.275, 21173294.
    • (2010) Arch Surg , vol.145 , pp. 1193-1200
    • Futier, E.1    Constantin, J.-M.2    Petit, A.3    Chanques, G.4    Kwiatkowski, F.5    Flamein, R.6    Slim, K.7    Sapin, V.8    Jaber, S.9    Bazin, J.-E.10
  • 81
    • 77957721641 scopus 로고    scopus 로고
    • Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management
    • Forget P, Lois F, de Kock M. Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management. Anesth Analg 2010, 111:910-914.
    • (2010) Anesth Analg , vol.111 , pp. 910-914
    • Forget, P.1    Lois, F.2    de Kock, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.