메뉴 건너뛰기




Volumn 36, Issue 9, 2010, Pages 1475-1483

Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: Systematic review and meta-analysis of clinical studies

Author keywords

Blood pressure; Blood volume; Cardiac output; Fluid therapy; Hemodynamics; Shock

Indexed keywords

AORTA FLOW; AREA UNDER THE CURVE; CARDIOVASCULAR PARAMETERS; CLINICAL TRIAL; COCHRANE LIBRARY; DIAGNOSTIC ACCURACY; EMBASE; HEART ARRHYTHMIA; HEART HEMODYNAMICS; HEART OUTPUT; HEART RHYTHM; HUMAN; MEDLINE; META ANALYSIS; PASSIVE LEG RAISING; PASSIVE MOVEMENT; PULSE PRESSURE; RECEIVER OPERATING CHARACTERISTIC; REVIEW; SENSITIVITY AND SPECIFICITY; SINUS RHYTHM; SYSTEMATIC REVIEW; VENTILATOR;

EID: 77955925229     PISSN: 03424642     EISSN: 14321238     Source Type: Journal    
DOI: 10.1007/s00134-010-1929-y     Document Type: Review
Times cited : (306)

References (28)
  • 1
    • 47549096309 scopus 로고    scopus 로고
    • Does central venous pressure predict fluid responsiveness?
    • DOI 10.1378/chest.07-2331
    • PE Marik M Baram B Vahid 2008 Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares Chest 134 172 178 10.1378/chest.07-2331 18628220 (Pubitemid 352008780)
    • (2008) Chest , vol.134 , Issue.1 , pp. 172-178
    • Marik, P.E.1    Baram, M.2    Vahid, B.3
  • 2
    • 42649125592 scopus 로고    scopus 로고
    • Functional hemodynamic monitoring and dynamic indices of fluid responsiveness
    • 18354368
    • F Cavallaro C Sandroni M Antonelli 2008 Functional hemodynamic monitoring and dynamic indices of fluid responsiveness Minerva Anestesiol 74 137 143 18354368
    • (2008) Minerva Anestesiol , vol.74 , pp. 137-143
    • Cavallaro, F.1    Sandroni, C.2    Antonelli, M.3
  • 3
    • 69349089330 scopus 로고    scopus 로고
    • Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature
    • 10.1097/CCM.0b013e3181a590da 19602972
    • PE Marik R Cavallazzi T Vasu A Hirani 2009 Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature Crit Care Med 37 2642 2647 10.1097/CCM.0b013e3181a590da 19602972
    • (2009) Crit Care Med , vol.37 , pp. 2642-2647
    • Marik, P.E.1    Cavallazzi, R.2    Vasu, T.3    Hirani, A.4
  • 4
    • 34247550826 scopus 로고    scopus 로고
    • How can the response to volume expansion in patients with spontaneous respiratory movements be predicted?
    • DOI 10.1186/cc4970
    • S Heenen D De Backer JL Vincent 2006 How can the response to volume expansion in patients with spontaneous respiratory movements be predicted? Crit Care 10 R102 10.1186/cc4970 16846530 (Pubitemid 47086899)
    • (2006) Critical Care , vol.10 , Issue.4
    • Heenen, S.1    De Backer, D.2    Vincent, J.-L.3
  • 5
    • 33748934573 scopus 로고    scopus 로고
    • Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation
    • DOI 10.1111/j.1399-6576.2006.01120.x
    • A Perner T Faber 2006 Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation Acta Anaesthesiol Scand 50 1068 1073 10.1111/j.1399-6576.2006.01120.x 1:STN:280:DC%2BD28rmtFCmtg%3D%3D 16939480 (Pubitemid 44434744)
    • (2006) Acta Anaesthesiologica Scandinavica , vol.50 , Issue.9 , pp. 1068-1073
    • Perner, A.1    Faber, T.2
  • 6
    • 25144499106 scopus 로고    scopus 로고
    • Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients
    • DOI 10.1007/s00134-005-2731-0
    • X Monnet M Rienzo D Osman N Anguel C Richard MR Pinsky JL Teboul 2005 Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients Intensive Care Med 31 1195 1201 10.1007/s00134-005-2731-0 16059723 (Pubitemid 41355795)
    • (2005) Intensive Care Medicine , vol.31 , Issue.9 , pp. 1195-1201
    • Monnet, X.1    Rienzo, M.2    Osman, D.3    Anguel, N.4    Richard, C.5    Pinsky, M.R.6    Teboul, J.-L.7
  • 7
    • 34447126479 scopus 로고    scopus 로고
    • Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients?
    • DOI 10.1007/s00134-007-0644-9
    • S Soubrier F Saulnier H Hubert P Delour H Lenci T Onimus S Nseir A Durocher 2007 Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients? Intensive Care Med 33 1117 1124 10.1007/s00134-007-0644-9 17508201 (Pubitemid 47036885)
    • (2007) Intensive Care Medicine , vol.33 , Issue.7 , pp. 1117-1124
    • Soubrier, S.1    Saulnier, F.2    Hubert, H.3    Delour, P.4    Lenci, H.5    Onimus, T.6    Nseir, S.7    Durocher, A.8
  • 8
    • 0019520514 scopus 로고
    • Radionuclide assessment of peripheral intravascular capacity: A technique to measure intravascular volume changes in the capacitance circulation in man
    • 1:STN:280:DyaL3M3htVGmsA%3D%3D 6786793
    • DL Rutlen FJ Wackers BL Zaret 1981 Radionuclide assessment of peripheral intravascular capacity: a technique to measure intravascular volume changes in the capacitance circulation in man Circulation 64 146 152 1:STN:280: DyaL3M3htVGmsA%3D%3D 6786793
    • (1981) Circulation , vol.64 , pp. 146-152
    • Rutlen, D.L.1    Wackers, F.J.2    Zaret, B.L.3
  • 9
    • 2942700307 scopus 로고    scopus 로고
    • The development of QUADAS: A tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews
    • 10.1186/1471-2288-3-25 14606960
    • P Whiting AW Rutjes JB Reitsma PM Bossuyt J Kleijnen 2003 The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews BMC Med Res Methodol 3 25 38 10.1186/1471-2288-3- 25 14606960
    • (2003) BMC Med Res Methodol , vol.3 , pp. 25-38
    • Whiting, P.1    Rutjes, A.W.2    Reitsma, J.B.3    Bossuyt, P.M.4    Kleijnen, J.5
  • 11
    • 0027290944 scopus 로고
    • Combining independent studies of a diagnostic test into a summary ROC curve: Data-analytic approaches and some additional considerations
    • 1:STN:280:DyaK2c%2FitlGkug%3D%3D 8210827
    • LE Moses D Shapiro B Littenberg 1993 Combining independent studies of a diagnostic test into a summary ROC curve: data-analytic approaches and some additional considerations Stat Med 12 1293 1316 1:STN:280:DyaK2c%2FitlGkug%3D%3D 8210827
    • (1993) Stat Med , vol.12 , pp. 1293-1316
    • Moses, L.E.1    Shapiro, D.2    Littenberg, B.3
  • 13
    • 67949121951 scopus 로고    scopus 로고
    • Non-invasive stroke volume measurement and passive leg raising predicts volume responsiveness in medical ICU patients: An observational cohort study
    • 10.1186/cc7955 19586543
    • SW Thiel MH Kollef W Isakow 2009 Non-invasive stroke volume measurement and passive leg raising predicts volume responsiveness in medical ICU patients: an observational cohort study Crit Care 13 R111 R120 10.1186/cc7955 19586543
    • (2009) Crit Care , vol.13
    • Thiel, S.W.1    Kollef, M.H.2    Isakow, W.3
  • 14
    • 0033610734 scopus 로고    scopus 로고
    • Improving the quality of reports of metaanalyses of randomised controlled trials: The QUOROM statement. Quality of reporting of meta-analyses
    • 10.1016/S0140-6736(99)04149-5 1:STN:280:DC%2BD3c%2FkvFCgtQ%3D%3D 10584742
    • D Moher DJ Cook S Eastwood I Olkin D Rennie DF Stroup 1999 Improving the quality of reports of metaanalyses of randomised controlled trials: the QUOROM statement. Quality of reporting of meta-analyses Lancet 354 1896 1900 10.1016/S0140-6736(99)04149-5 1:STN:280:DC%2BD3c%2FkvFCgtQ%3D%3D 10584742
    • (1999) Lancet , vol.354 , pp. 1896-1900
    • Moher, D.1    Cook, D.J.2    Eastwood, S.3    Olkin, I.4    Rennie, D.5    Stroup, D.F.6
  • 15
    • 84925548115 scopus 로고    scopus 로고
    • Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
    • the PRISMA group. 10.1016/j.jclinepi.2009.06.005 19631508
    • D Moher A Liberati J Tetzlaff DG Altman the PRISMA group 2009 Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement J Clin Epidemiol 62 1006 1012 10.1016/j.jclinepi.2009.06.005 19631508
    • (2009) J Clin Epidemiol , vol.62 , pp. 1006-1012
    • Moher, D.1    Liberati, A.2    Tetzlaff, J.3    Altman, D.G.4
  • 16
    • 58549089484 scopus 로고    scopus 로고
    • Passive leg raising for predicting fluid responsiveness: Importance of the postural change
    • 10.1007/s00134-008-1293-3 18795254
    • J Jabot JL Teboul C Richard X Monnet 2009 Passive leg raising for predicting fluid responsiveness: importance of the postural change Intensive Care Med 35 85 90 10.1007/s00134-008-1293-3 18795254
    • (2009) Intensive Care Med , vol.35 , pp. 85-90
    • Jabot, J.1    Teboul, J.L.2    Richard, C.3    Monnet, X.4
  • 17
    • 0036206081 scopus 로고    scopus 로고
    • Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients
    • DOI 10.1378/chest.121.4.1245
    • T Boulain JM Achard JL Teboul C Richard D Perrotin G Ginies 2002 Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients Chest 121 1245 1252 10.1378/chest.121.4.1245 11948060 (Pubitemid 34280450)
    • (2002) Chest , vol.121 , Issue.4 , pp. 1245-1252
    • Boulain, T.1    Achard, J.-M.2    Teboul, J.-L.3    Richard, C.4    Perrotin, D.5    Ginies, G.6
  • 18
  • 19
    • 33646577770 scopus 로고    scopus 로고
    • Passive leg raising predicts fluid responsiveness in the critically ill
    • 10.1097/01.CCM.0000215453.11735.06 16540963
    • X Monnet M Rienzo D Osman N Anguel C Richard MR Pinsky JL Teboul 2006 Passive leg raising predicts fluid responsiveness in the critically ill Crit Care Med 34 1402 1407 10.1097/01.CCM.0000215453.11735.06 16540963
    • (2006) Crit Care Med , vol.34 , pp. 1402-1407
    • Monnet, X.1    Rienzo, M.2    Osman, D.3    Anguel, N.4    Richard, C.5    Pinsky, M.R.6    Teboul, J.L.7
  • 20
    • 34447117107 scopus 로고    scopus 로고
    • Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity
    • DOI 10.1007/s00134-007-0646-7
    • B Lamia A Ochagavia X Monnet D Chemla C Richard JL Teboul 2007 Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity Intensive Care Med 33 1125 1132 10.1007/s00134-007-0646-7 17508199 (Pubitemid 47036887)
    • (2007) Intensive Care Medicine , vol.33 , Issue.7 , pp. 1125-1132
    • Lamia, B.1    Ochagavia, A.2    Monnet, X.3    Chemla, D.4    Richard, C.5    Teboul, J.-L.6
  • 21
    • 34447128304 scopus 로고    scopus 로고
    • Diagnosis of central hypovolemia by using passive leg raising
    • DOI 10.1007/s00134-007-0642-y
    • J Maizel N Airapetian E Lorne C Tribouilloy Z Massy M Slama 2007 Diagnosis of central hypovolemia by using passive leg raising Intensive Care Med 33 1133 1138 10.1007/s00134-007-0642-y 17508202 (Pubitemid 47036884)
    • (2007) Intensive Care Medicine , vol.33 , Issue.7 , pp. 1133-1138
    • Maizel, J.1    Airapetian, N.2    Lorne, E.3    Tribouilloy, C.4    Massy, Z.5    Slama, M.6
  • 22
    • 62849122288 scopus 로고    scopus 로고
    • Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients
    • 10.1097/CCM.0b013e3181968fe1 19237902
    • X Monnet D Osman C Ridel B Lamia C Richard JL Teboul 2009 Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients Crit Care Med 37 951 956 10.1097/CCM.0b013e3181968fe1 19237902
    • (2009) Crit Care Med , vol.37 , pp. 951-956
    • Monnet, X.1    Osman, D.2    Ridel, C.3    Lamia, B.4    Richard, C.5    Teboul, J.L.6
  • 23
    • 77951636130 scopus 로고    scopus 로고
    • Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: Comparison between echocardiography and Vigileo TM/FloTracTM device
    • 10.1186/cc8195 19968880
    • M Biais L Vidil P Sarrabay V Cottenceau P Revel F Sztark 2009 Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo TM/FloTracTM device Crit Care 13 R195 10.1186/cc8195 19968880
    • (2009) Crit Care , vol.13 , pp. 195
    • Biais, M.1    Vidil, L.2    Sarrabay, P.3    Cottenceau, V.4    Revel, P.5    Sztark, F.6
  • 24
    • 77249174785 scopus 로고    scopus 로고
    • Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis
    • 10.1097/CCM.0b013e3181c8fe7a 20016380
    • S Préau F Saulnier F Dewavrin A Durocher JL Chagnon 2010 Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis Crit Care Med 38 819 825 10.1097/CCM.0b013e3181c8fe7a 20016380
    • (2010) Crit Care Med , vol.38 , pp. 819-825
    • Préau, S.1    Saulnier, F.2    Dewavrin, F.3    Durocher, A.4    Chagnon, J.L.5
  • 25
    • 0033797681 scopus 로고    scopus 로고
    • Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation
    • 10.1186/cc710 1:STN:280:DC%2BD3M7jtlSlsg%3D%3D 11094507
    • F Michard JL Teboul 2000 Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation Critical Care 4 282 289 10.1186/cc710 1:STN:280:DC%2BD3M7jtlSlsg%3D%3D 11094507
    • (2000) Critical Care , vol.4 , pp. 282-289
    • Michard, F.1    Teboul, J.L.2
  • 26
    • 0034968042 scopus 로고    scopus 로고
    • Implications of arterial pressure variation in patients in the intensive care unit
    • DOI 10.1097/00075198-200106000-00012
    • SR Gunn MR Pinsky 2001 Implications of arterial pressure variation in patients in the intensive care unit Curr Opin Crit Care 7 212 217 10.1097/00075198-200106000-00012 1:STN:280:DC%2BD38%2FhslGntA%3D%3D 11436530 (Pubitemid 32552737)
    • (2001) Current Opinion in Critical Care , vol.7 , Issue.3 , pp. 212-217
    • Gunn, S.R.1    Pinsky, M.R.2
  • 27
    • 46149116113 scopus 로고    scopus 로고
    • Hemodynamic effects of passive leg raising: An echocardiographic study in patients with shock
    • DOI 10.1007/s00134-008-1067-y
    • V Caille J Jabot G Belliard C Charron F Jardin A Vieillard-Baron 2008 Hemodynamic effects of passive leg raising: an echocardiographic study in patients with shock Intensive Care Med 34 1239 1245 10.1007/s00134-008-1067-y 18351322 (Pubitemid 351904298)
    • (2008) Intensive Care Medicine , vol.34 , Issue.7 , pp. 1239-1245
    • Caille, V.1    Jabot, J.2    Belliard, G.3    Charron, C.4    Jardin, F.5    Vieillard-Baron, A.6
  • 28
    • 43349086860 scopus 로고    scopus 로고
    • Passive leg raising
    • 10.1007/s00134-008-0994-y 18214429
    • X Monnet JL Teboul 2008 Passive leg raising Intensive Care Med 34 659 663 10.1007/s00134-008-0994-y 18214429
    • (2008) Intensive Care Med , vol.34 , pp. 659-663
    • Monnet, X.1    Teboul, J.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.