1
-
-
0004086855
-
-
Marcel Dekker, Inc. New York p. 539
-
R. Rice Porosity of ceramics 1998 Marcel Dekker, Inc. New York p. 539
-
(1998)
Porosity of Ceramics
-
-
Rice, R.1
-
4
-
-
0030307204
-
Microcracks in dental porcelains and their behavior during multiple firing
-
J.R. Mackert Jr., and A.L. Williams Microcracks in dental porcelains and their behavior during multiple firing Journal of Dental Research 75 1996 1484 1490
-
(1996)
Journal of Dental Research
, vol.75
, pp. 1484-1490
-
-
MacKert, Jr.J.R.1
Williams, A.L.2
-
6
-
-
84859558876
-
Strength and fracture origins of a feldspathic porcelain
-
G.D. Quinn, K. Hoffman, and J.B. Quinn Strength and fracture origins of a feldspathic porcelain Dental Materials 28 2012 502 511
-
(2012)
Dental Materials
, vol.28
, pp. 502-511
-
-
Quinn, G.D.1
Hoffman, K.2
Quinn, J.B.3
-
7
-
-
10744222195
-
Current status of zirconia used in total hip implants
-
I.C. Clarke, M. Manaka, D.D. Green, P. Williams, G. Pezzotti, and Y.H. Kim Current status of zirconia used in total hip implants Journal of Bone and Joint Surgery 85A 2003 73 84
-
(2003)
Journal of Bone and Joint Surgery
, vol.85 A
, pp. 73-84
-
-
Clarke, I.C.1
Manaka, M.2
Green, D.D.3
Williams, P.4
Pezzotti, G.5
Kim, Y.H.6
-
8
-
-
80255135584
-
Mapping the tetragonal to monoclinic phase transformation in zirconia core dental crowns
-
M. Allahkarami, and J.C. Hanan Mapping the tetragonal to monoclinic phase transformation in zirconia core dental crowns Dental Materials 27 2011 1279 1284
-
(2011)
Dental Materials
, vol.27
, pp. 1279-1284
-
-
Allahkarami, M.1
Hanan, J.C.2
-
12
-
-
0029318343
-
Failure of all-ceramic fixed partial dentures in vitro and in vivo: Analysis and modeling
-
J.R. Kelly, J.A. Tesk, and J.A. Sorensen Failure of all-ceramic fixed partial dentures in vitro and in vivo: analysis and modeling Journal of Dental Research 74 1995 1253 1258
-
(1995)
Journal of Dental Research
, vol.74
, pp. 1253-1258
-
-
Kelly, J.R.1
Tesk, J.A.2
Sorensen, J.A.3
-
13
-
-
0033186574
-
Fracture toughness (KIc) of a dental porcelain determined by fractographic analysis
-
S.S. Scherrer, J.R. Kelly, G.D. Quinn, and K. Xu Fracture toughness (KIc) of a dental porcelain determined by fractographic analysis Dental Materials 15 1999 342 348
-
(1999)
Dental Materials
, vol.15
, pp. 342-348
-
-
Scherrer, S.S.1
Kelly, J.R.2
Quinn, G.D.3
Xu, K.4
-
14
-
-
45049087586
-
Fractographic failure analysis of a Procera (R) AllCeram crown using stereo and scanning electron microscopy
-
S.S. Scherrer, G.D. Quinn, and J.B. Quinn Fractographic failure analysis of a Procera (R) AllCeram crown using stereo and scanning electron microscopy Dental Materials 24 2008 1107 1113
-
(2008)
Dental Materials
, vol.24
, pp. 1107-1113
-
-
Scherrer, S.S.1
Quinn, G.D.2
Quinn, J.B.3
-
17
-
-
45049088335
-
Fractographic analyses of zirconia-based fixed partial dentures
-
B. Taskonak, J. Yan, J.J. Mecholsky, A. Sertgoz, and A. Kocak Fractographic analyses of zirconia-based fixed partial dentures Dental Materials 24 2008 1077 1082
-
(2008)
Dental Materials
, vol.24
, pp. 1077-1082
-
-
Taskonak, B.1
Yan, J.2
Mecholsky, J.J.3
Sertgoz, A.4
Kocak, A.5
-
18
-
-
0029258584
-
Fractography - Determining the sites of fracture initiation
-
J.J. Mecholsky Fractography - determining the sites of fracture initiation Dental Materials 11 1995 113 116
-
(1995)
Dental Materials
, vol.11
, pp. 113-116
-
-
Mecholsky, J.J.1
-
19
-
-
25144475575
-
Fractographic analyses of three ceramic whole crown restoration failures
-
J.B. Quinn, G.D. Quinn, J.R. Kelly, and S.S. Scherrer Fractographic analyses of three ceramic whole crown restoration failures Dental Materials 21 2005 920 929
-
(2005)
Dental Materials
, vol.21
, pp. 920-929
-
-
Quinn, J.B.1
Quinn, G.D.2
Kelly, J.R.3
Scherrer, S.S.4
-
20
-
-
84871016978
-
Ceramic fracture mode-Intergranular vs. transgranular fracture
-
J. Varner, V. Fréchette, G. Quinn, The American Ceramic Society Westerville, OH
-
R.W. Rice Ceramic fracture mode-Intergranular vs. transgranular fracture J. Varner, V. Fréchette, G. Quinn, Fractography of glass and ceramics III 1996 The American Ceramic Society Westerville, OH 1 53
-
(1996)
Fractography of Glass and Ceramics III
, pp. 1-53
-
-
Rice, R.W.1
-
21
-
-
80955143717
-
Influence of the fabrication process on the in vitro performance of fixed dental prostheses with zirconia substructures
-
M. Rosentritt, C. Kolbeck, G. Handel, S. Schneider-Feyrer, and M. Behr Influence of the fabrication process on the in vitro performance of fixed dental prostheses with zirconia substructures Clinical Oral Investigations 15 2011 1007 1012
-
(2011)
Clinical Oral Investigations
, vol.15
, pp. 1007-1012
-
-
Rosentritt, M.1
Kolbeck, C.2
Handel, G.3
Schneider-Feyrer, S.4
Behr, M.5
-
22
-
-
80053634985
-
Thermal gradients and residual stresses in veneered Y-TZP frameworks
-
M.J. Tholey, M.V. Swain, and N. Thiel Thermal gradients and residual stresses in veneered Y-TZP frameworks Dental Materials 27 2011 1102 1110
-
(2011)
Dental Materials
, vol.27
, pp. 1102-1110
-
-
Tholey, M.J.1
Swain, M.V.2
Thiel, N.3
-
24
-
-
36749015193
-
Residual stress and its role in failure
-
P.J. Withers Residual stress and its role in failure Reports on Progress in Physics 70 2007 2211 2264
-
(2007)
Reports on Progress in Physics
, vol.70
, pp. 2211-2264
-
-
Withers, P.J.1
-
25
-
-
67349133480
-
Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures
-
M.V. Swain Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures Acta Biomaterialia 5 2009 1668 1677
-
(2009)
Acta Biomaterialia
, vol.5
, pp. 1668-1677
-
-
Swain, M.V.1
-
26
-
-
71049124440
-
Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs)
-
F. Beuer, D. Edelhoff, W. Gernet, and J.A. Sorensen Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs) Clinical Oral Investigations 13 2009 445 451
-
(2009)
Clinical Oral Investigations
, vol.13
, pp. 445-451
-
-
Beuer, F.1
Edelhoff, D.2
Gernet, W.3
Sorensen, J.A.4
-
27
-
-
34250653055
-
Five-year clinical results of zirconia frameworks for posterior fixed partial dentures
-
I. Sailer, A. Feher, F. Filser, L.J. Gauckler, H. Luthy, and C.H.F. Hammerle Five-year clinical results of zirconia frameworks for posterior fixed partial dentures International Journal of Prosthodontics 20 2007 383 388
-
(2007)
International Journal of Prosthodontics
, vol.20
, pp. 383-388
-
-
Sailer, I.1
Feher, A.2
Filser, F.3
Gauckler, L.J.4
Luthy, H.5
Hammerle, C.H.F.6
-
28
-
-
0016071137
-
Slow crack growth in brittle materials under dynamic loading conditions
-
A. Evans Slow crack growth in brittle materials under dynamic loading conditions International Journal of Fatigue 10 1974 251 259
-
(1974)
International Journal of Fatigue
, vol.10
, pp. 251-259
-
-
Evans, A.1
-
32
-
-
37049008055
-
Correlation of in vitro fatigue data and in vivo clinical performance of a glassceramic material
-
U. Lohbauer, N. Kramer, A. Petschelt, and R. Frankenberger Correlation of in vitro fatigue data and in vivo clinical performance of a glassceramic material Dental Materials 24 2008 39 44
-
(2008)
Dental Materials
, vol.24
, pp. 39-44
-
-
Lohbauer, U.1
Kramer, N.2
Petschelt, A.3
Frankenberger, R.4
-
33
-
-
1842732685
-
Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part I. Pressable and alumina glass-infiltrated ceramics
-
M. Guazzato, M. Albakry, S.P. Ringer, and M.V. Swain Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part I. Pressable and alumina glass-infiltrated ceramics Dental Materials 20 2004 441 448
-
(2004)
Dental Materials
, vol.20
, pp. 441-448
-
-
Guazzato, M.1
Albakry, M.2
Ringer, S.P.3
Swain, M.V.4
-
34
-
-
4644251547
-
Influence of hot pressing on the microstructure and fracture toughness of two pressable dental glass-ceramics
-
M. Albakry, M. Guazzato, and M.V. Swain Influence of hot pressing on the microstructure and fracture toughness of two pressable dental glass-ceramics Journal of Biomedical Materials Research 71B 2004 99 107
-
(2004)
Journal of Biomedical Materials Research
, vol.71 B
, pp. 99-107
-
-
Albakry, M.1
Guazzato, M.2
Swain, M.V.3
-
35
-
-
1842783267
-
Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics
-
M. Guazzato, M. Albakry, S.P. Ringer, and M.V. Swain Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics Dental Materials 20 2004 449 456
-
(2004)
Dental Materials
, vol.20
, pp. 449-456
-
-
Guazzato, M.1
Albakry, M.2
Ringer, S.P.3
Swain, M.V.4
-
36
-
-
79953299288
-
Ceramics for dental applications: A review
-
I. Denry, and J. Holloway Ceramics for dental applications: a review Materials 3 2010 351 368
-
(2010)
Materials
, vol.3
, pp. 351-368
-
-
Denry, I.1
Holloway, J.2
-
37
-
-
38349192796
-
State of the art of zirconia for dental applications
-
I. Denry, and J.R. Kelly State of the art of zirconia for dental applications Dental Materials 24 2008 299 307
-
(2008)
Dental Materials
, vol.24
, pp. 299-307
-
-
Denry, I.1
Kelly, J.R.2
-
38
-
-
38349162274
-
Stabilized zirconia as a structural material
-
J.R. Kelly, and I. Denry Stabilized zirconia as a structural material Dental Materials 24 2008 289 298
-
(2008)
Dental Materials
, vol.24
, pp. 289-298
-
-
Kelly, J.R.1
Denry, I.2
-
41
-
-
42649115453
-
Possible triggers for phase transformation in zirconia hip balls
-
S.S. Brown, D.D. Green, G. Pezzotti, T.K. Donaldson, and I.C. Clarke Possible triggers for phase transformation in zirconia hip balls Journal of Biomedical Materials Research B-Applied Biomaterials 85B 2008 444 452
-
(2008)
Journal of Biomedical Materials Research B-Applied Biomaterials
, vol.85 B
, pp. 444-452
-
-
Brown, S.S.1
Green, D.D.2
Pezzotti, G.3
Donaldson, T.K.4
Clarke, I.C.5
-
42
-
-
0032201909
-
Microstructure evolution and grain growth in the sintering of 3Y-TZP ceramics
-
J. Luo, S. Adak, and R. Stevens Microstructure evolution and grain growth in the sintering of 3Y-TZP ceramics Journal of Materials Science 33 1998 5301 5309
-
(1998)
Journal of Materials Science
, vol.33
, pp. 5301-5309
-
-
Luo, J.1
Adak, S.2
Stevens, R.3
-
44
-
-
0016549634
-
Phase relationships in the zirconia-yttria system
-
H.G. Scott Phase relationships in the zirconia-yttria system Journal of Materials Science 10 1975 1527 1535
-
(1975)
Journal of Materials Science
, vol.10
, pp. 1527-1535
-
-
Scott, H.G.1
-
45
-
-
2342500842
-
Critical effect of cubic phase on aging in 3 mol.% yttria-stabilized zirconia ceramics for hip replacement prosthesis
-
J. Chevalier, S. Deville, E. Münch, R. Jullian, and F. Lair Critical effect of cubic phase on aging in 3 mol.% yttria-stabilized zirconia ceramics for hip replacement prosthesis Biomaterials 25 2004 5539 5545
-
(2004)
Biomaterials
, vol.25
, pp. 5539-5545
-
-
Chevalier, J.1
Deville, S.2
Münch, E.3
Jullian, R.4
Lair, F.5
-
46
-
-
0043011555
-
Cubic-formation and grain-growth mechanisms in tetragonal zirconia polycrystal
-
K. Matsui, H. Horikoshi, N. Ohmichi, M. Ohgai, H. Yoshida, and Y. Ikuhara Cubic-formation and grain-growth mechanisms in tetragonal zirconia polycrystal Journal of the American Ceramic Society 86 2003 1401 1408
-
(2003)
Journal of the American Ceramic Society
, vol.86
, pp. 1401-1408
-
-
Matsui, K.1
Horikoshi, H.2
Ohmichi, N.3
Ohgai, M.4
Yoshida, H.5
Ikuhara, Y.6
-
47
-
-
0021392111
-
Pores as fracture origins in ceramics
-
R.W. Rice Pores as fracture origins in ceramics Journal of Materials Science 19 1984 895 914
-
(1984)
Journal of Materials Science
, vol.19
, pp. 895-914
-
-
Rice, R.W.1
-
48
-
-
3843095302
-
Scaling of fracture strength in ZnO: Effects of pore/grain-size interaction and porosity
-
C.S. Lu, R. Danzer, and F.D. Fischer Scaling of fracture strength in ZnO: effects of pore/grain-size interaction and porosity Journal of the European Ceramic Society 24 2004 3643 3651
-
(2004)
Journal of the European Ceramic Society
, vol.24
, pp. 3643-3651
-
-
Lu, C.S.1
Danzer, R.2
Fischer, F.D.3
-
49
-
-
84987360747
-
Large localized surface stresses caused by thermal expansion anisotropy
-
J.B. Wachtman, and J. Dundurs Large localized surface stresses caused by thermal expansion anisotropy Journal of the American Ceramic Society 54 1971 525-526
-
(1971)
Journal of the American Ceramic Society
, vol.54
, pp. 525-526
-
-
Wachtman, J.B.1
Dundurs, J.2
-
51
-
-
79960448795
-
Performance of dental ceramics: Challenges for improvements
-
E.D. Rekow, N. Silva, P.G. Coelho, Y. Zhang, P. Guess, and V.P. Thompson Performance of dental ceramics: challenges for improvements Journal of Dental Research 90 2011 937 952
-
(2011)
Journal of Dental Research
, vol.90
, pp. 937-952
-
-
Rekow, E.D.1
Silva, N.2
Coelho, P.G.3
Zhang, Y.4
Guess, P.5
Thompson, V.P.6
-
52
-
-
33749339232
-
Computer-aided design and fabrication of dental restorations - Current systems and future possibilities
-
J.R. Strub, E.D. Rekow, and S. Witkowski Computer-aided design and fabrication of dental restorations - current systems and future possibilities Journal of the American Dental Association 137 2006 1289 1296
-
(2006)
Journal of the American Dental Association
, vol.137
, pp. 1289-1296
-
-
Strub, J.R.1
Rekow, E.D.2
Witkowski, S.3
-
53
-
-
0036722317
-
Monolithic and composite ceramic machining flaw-micro structure-strength effects: Model evaluation
-
R.W. Rice Monolithic and composite ceramic machining flaw-micro structure-strength effects: model evaluation Journal of the European Ceramic Society 22 2002 1411 1424
-
(2002)
Journal of the European Ceramic Society
, vol.22
, pp. 1411-1424
-
-
Rice, R.W.1
-
56
-
-
0033222358
-
The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic
-
T. Kosmac, C. Oblak, P. Jevnikar, N. Funduk, and L. Marion The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic Dental Materials 15 1999 426 433
-
(1999)
Dental Materials
, vol.15
, pp. 426-433
-
-
Kosmac, T.1
Oblak, C.2
Jevnikar, P.3
Funduk, N.4
Marion, L.5
-
57
-
-
0033858120
-
Strength and reliability of surface treated Y-TZP dental ceramics
-
T. Kosmac, C. Oblak, P. Jevnikar, N. Funduk, and L. Marion Strength and reliability of surface treated Y-TZP dental ceramics Journal of Biomedical Materials Research 53 2000 304 313
-
(2000)
Journal of Biomedical Materials Research
, vol.53
, pp. 304-313
-
-
Kosmac, T.1
Oblak, C.2
Jevnikar, P.3
Funduk, N.4
Marion, L.5
-
58
-
-
38149012120
-
The effects of dental grinding and sandblasting on ageing and fatigue behavior of dental zirconia (Y-TZP) ceramics
-
T. Kosmac, C. Oblak, and L. Marion The effects of dental grinding and sandblasting on ageing and fatigue behavior of dental zirconia (Y-TZP) ceramics Journal of the European Ceramic Society 28 2008 1085 1090
-
(2008)
Journal of the European Ceramic Society
, vol.28
, pp. 1085-1090
-
-
Kosmac, T.1
Oblak, C.2
Marion, L.3
-
59
-
-
11844264547
-
Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramic
-
M. Guazzato, L. Quach, M. Albakry, and M.V. Swain Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramic Journal of Dentistry 33 2005 9 18
-
(2005)
Journal of Dentistry
, vol.33
, pp. 9-18
-
-
Guazzato, M.1
Quach, L.2
Albakry, M.3
Swain, M.V.4
-
60
-
-
26844583254
-
What future for zirconia as a biomaterial?
-
J. Chevalier What future for zirconia as a biomaterial? Biomaterials 27 2006 535 543
-
(2006)
Biomaterials
, vol.27
, pp. 535-543
-
-
Chevalier, J.1
-
62
-
-
33749677224
-
The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: A prospective clinical pilot study
-
A.J. Raigrodski, G.J. Chiche, N. Potiket, J.L. Hochstedler, S.E. Mohamed, and S. Billiot The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study Journal of Prosthetic Dentistry 96 2006 237 244
-
(2006)
Journal of Prosthetic Dentistry
, vol.96
, pp. 237-244
-
-
Raigrodski, A.J.1
Chiche, G.J.2
Potiket, N.3
Hochstedler, J.L.4
Mohamed, S.E.5
Billiot, S.6
-
64
-
-
79952260010
-
Five-year follow-up of implant-supported Y-TZP and ZTA fixed dental prostheses. A randomized, prospective clinical trial comparing two different material systems
-
C. Larsson, and P.V. von Steyern Five-year follow-up of implant-supported Y-TZP and ZTA fixed dental prostheses. A randomized, prospective clinical trial comparing two different material systems International Journal of Prosthodontics 23 2010 555 561
-
(2010)
International Journal of Prosthodontics
, vol.23
, pp. 555-561
-
-
Larsson, C.1
Von Steyern, P.V.2
-
65
-
-
77957270939
-
A prospective study of implant-supported full-arch yttria-stabilized tetragonal zirconia polycrystal mandibular fixed dental prostheses: Three-year results
-
C. Larsson, P.V. von Steyern, and K. Nilner A prospective study of implant-supported full-arch yttria-stabilized tetragonal zirconia polycrystal mandibular fixed dental prostheses: three-year results International Journal of Prosthodontics 23 2010 364 369
-
(2010)
International Journal of Prosthodontics
, vol.23
, pp. 364-369
-
-
Larsson, C.1
Von Steyern, P.V.2
Nilner, K.3
-
66
-
-
77952296078
-
Prospective evaluation of zirconia posterior fixed partial dentures: Four-year clinical results
-
M. Roediger, N. Gersdorff, A. Huels, and S. Rinke Prospective evaluation of zirconia posterior fixed partial dentures: four-year clinical results International Journal of Prosthodontics 23 2010 141 148
-
(2010)
International Journal of Prosthodontics
, vol.23
, pp. 141-148
-
-
Roediger, M.1
Gersdorff, N.2
Huels, A.3
Rinke, S.4
-
67
-
-
77449113504
-
Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: A 3-year follow-up
-
I. Sailer, J. Gottner, S. Kanel, and C.H.F. Hammerle Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up International Journal of Prosthodontics 22 2009 553 560
-
(2009)
International Journal of Prosthodontics
, vol.22
, pp. 553-560
-
-
Sailer, I.1
Gottner, J.2
Kanel, S.3
Hammerle, C.H.F.4
-
69
-
-
73149124508
-
Four-year clinical results of fixed dental prostheses with zirconia substructures (Cercon): End abutments vs. cantilever design
-
S. Wolfart, S. Harder, S. Eschbach, F. Lehmann, and M. Kern Four-year clinical results of fixed dental prostheses with zirconia substructures (Cercon): end abutments vs. cantilever design European Journal of Oral Sciences 117 2009 741 749
-
(2009)
European Journal of Oral Sciences
, vol.117
, pp. 741-749
-
-
Wolfart, S.1
Harder, S.2
Eschbach, S.3
Lehmann, F.4
Kern, M.5
-
70
-
-
33745810915
-
All-ceramic two- and five-unit implant-supported reconstructions. A randomized, prospective clinical trial
-
C. Larsson, P.V. von Steyern, B. Sunzel, and K. Nilner All-ceramic two- and five-unit implant-supported reconstructions. A randomized, prospective clinical trial Swedish Dental Journal 30 2006 45 53
-
(2006)
Swedish Dental Journal
, vol.30
, pp. 45-53
-
-
Larsson, C.1
Von Steyern, P.V.2
Sunzel, B.3
Nilner, K.4
-
72
-
-
79952273419
-
Survival of zirconia- and metal-supported fixed dental prostheses: A systematic review
-
S.D. Heintze, and V. Rousson Survival of zirconia- and metal-supported fixed dental prostheses: a systematic review International Journal of Prosthodontics 23 2010 493 502
-
(2010)
International Journal of Prosthodontics
, vol.23
, pp. 493-502
-
-
Heintze, S.D.1
Rousson, V.2
-
73
-
-
77956529457
-
Survival probability of zirconia-based fixed dental prostheses up to 5 years: A systematic review of the literature
-
J.S. Schley, N. Heussen, S. Reich, J. Fischer, K. Haselhuhn, and S. Wolfart Survival probability of zirconia-based fixed dental prostheses up to 5 years: a systematic review of the literature European Journal of Oral Sciences 118 2010 443 450
-
(2010)
European Journal of Oral Sciences
, vol.118
, pp. 443-450
-
-
Schley, J.S.1
Heussen, N.2
Reich, S.3
Fischer, J.4
Haselhuhn, K.5
Wolfart, S.6
-
75
-
-
67349133480
-
Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures
-
M.V. Swain Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures Acta Biomaterials 2009
-
(2009)
Acta Biomaterials
-
-
Swain, M.V.1
-
76
-
-
80053642176
-
Pressed ceramics onto zirconia. Part 2: Indentation fracture and influence of cooling rate on residual stresses
-
J.E. Choi, J.N. Waddell, and M.V. Swain Pressed ceramics onto zirconia. Part 2: indentation fracture and influence of cooling rate on residual stresses Dental Materials 27 2011 1111 1118
-
(2011)
Dental Materials
, vol.27
, pp. 1111-1118
-
-
Choi, J.E.1
Waddell, J.N.2
Swain, M.V.3
-
77
-
-
84858081594
-
Influence of zirconia framework thickness on residual stress profile in veneering ceramic: Measurement by hole-drilling
-
A.K. Mainjot, G.S. Schajer, A.J. Vanheusden, and M.J. Sadoun Influence of zirconia framework thickness on residual stress profile in veneering ceramic: measurement by hole-drilling Dental Materials 28 2012 378 384
-
(2012)
Dental Materials
, vol.28
, pp. 378-384
-
-
Mainjot, A.K.1
Schajer, G.S.2
Vanheusden, A.J.3
Sadoun, M.J.4
-
78
-
-
84855776440
-
Influence of veneer thickness on residual stress profile in veneering ceramic: Measurement by hole-drilling
-
A.K. Mainjot, G.S. Schajer, A.J. Vanheusden, and M.J. Sadoun Influence of veneer thickness on residual stress profile in veneering ceramic: measurement by hole-drilling Dental Materials 28 2012 160 167
-
(2012)
Dental Materials
, vol.28
, pp. 160-167
-
-
Mainjot, A.K.1
Schajer, G.S.2
Vanheusden, A.J.3
Sadoun, M.J.4
-
80
-
-
67650918068
-
Clinical performance of extended zirconia frameworks for fixed dental prostheses: Two-year results
-
M. Schmitter, K. Mussotter, P. Rammelsberg, T. Stober, B. Ohlmann, and O. Gabbert Clinical performance of extended zirconia frameworks for fixed dental prostheses: two-year results Journal of Oral Rehabilitation 36 2009 610 615
-
(2009)
Journal of Oral Rehabilitation
, vol.36
, pp. 610-615
-
-
Schmitter, M.1
Mussotter, K.2
Rammelsberg, P.3
Stober, T.4
Ohlmann, B.5
Gabbert, O.6
-
81
-
-
59149106280
-
CAD/CAM zirconia vs. slip-cast glass-infiltrated alumina/zirconia all-ceramic crowns: 2-year results of a randomized controlled clinical trial
-
M.C. Cehreli, A.M. Kokat, and K. Akca CAD/CAM zirconia vs. slip-cast glass-infiltrated alumina/zirconia all-ceramic crowns: 2-year results of a randomized controlled clinical trial Journal of Applied Oral Science 17 2009 49 55
-
(2009)
Journal of Applied Oral Science
, vol.17
, pp. 49-55
-
-
Cehreli, M.C.1
Kokat, A.M.2
Akca, K.3
-
82
-
-
84977695915
-
Influence of water vapor on crack propagation in glass
-
S. Wiederhorn Influence of water vapor on crack propagation in glass Journal of the American Ceramic Society 50 1967 407 414
-
(1967)
Journal of the American Ceramic Society
, vol.50
, pp. 407-414
-
-
Wiederhorn, S.1
-
83
-
-
0019898001
-
A molecular interpretation of stress corrosion in silica
-
T. Michalske, and S. Freiman A molecular interpretation of stress corrosion in silica Nature 295 1982 511 512
-
(1982)
Nature
, vol.295
, pp. 511-512
-
-
Michalske, T.1
Freiman, S.2
-
84
-
-
84255197862
-
Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal-ceramic fixed dental prostheses
-
K.J. Anusavice Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal-ceramic fixed dental prostheses Dental Materials 28 2012 102 111
-
(2012)
Dental Materials
, vol.28
, pp. 102-111
-
-
Anusavice, K.J.1
-
85
-
-
77952312739
-
Fracture rates of IPS empress all-ceramic crowns - A systematic review
-
S.D. Heintze, and V. Rousson Fracture rates of IPS empress all-ceramic crowns-a systematic review International Journal of Prosthodontics 23 2010 129 133
-
(2010)
International Journal of Prosthodontics
, vol.23
, pp. 129-133
-
-
Heintze, S.D.1
Rousson, V.2
-
86
-
-
34250636079
-
Which mechanical and physical testing methods are relevant for predicting the clinical performance of ceramic-based dental prostheses?
-
K.F. Anusavice, K. Kakar, and N. Ferree Which mechanical and physical testing methods are relevant for predicting the clinical performance of ceramic-based dental prostheses? Clinical Oral Implants Research 18 2007 218 231
-
(2007)
Clinical Oral Implants Research
, vol.18
, pp. 218-231
-
-
Anusavice, K.F.1
Kakar, K.2
Ferree, N.3
-
89
-
-
43749099417
-
HIP zirconia fixed partial dentures - Clinical results after 3 years of clinical service
-
D. Edelhoff, F. Beuer, V. Weber, and C. Johnen HIP zirconia fixed partial dentures - clinical results after 3 years of clinical service Quintessence International 39 2008 459 471
-
(2008)
Quintessence International
, vol.39
, pp. 459-471
-
-
Edelhoff, D.1
Beuer, F.2
Weber, V.3
Johnen, C.4
-
90
-
-
48549103602
-
All-ceramic inlay-retained fixed partial dentures: Preliminary results from a clinical study
-
B. Ohlmann, P. Rammelsberg, M. Schmitter, S. Schwarz, and O. Gabbert All-ceramic inlay-retained fixed partial dentures: preliminary results from a clinical study Journal of Dentistry 36 2008 692 696
-
(2008)
Journal of Dentistry
, vol.36
, pp. 692-696
-
-
Ohlmann, B.1
Rammelsberg, P.2
Schmitter, M.3
Schwarz, S.4
Gabbert, O.5
-
91
-
-
44849111859
-
Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs
-
M.K. Molin, and S.L. Karlsson Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs International Journal of Prosthodontics 21 2008 223 227
-
(2008)
International Journal of Prosthodontics
, vol.21
, pp. 223-227
-
-
Molin, M.K.1
Karlsson, S.L.2
-
92
-
-
44849090314
-
Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results
-
J. Tinschert, K.A. Schulze, G. Natt, P. Latzke, N. Heussen, and H. Spiekermann Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results International Journal of Prosthodontics 21 2008 217 222
-
(2008)
International Journal of Prosthodontics
, vol.21
, pp. 217-222
-
-
Tinschert, J.1
Schulze, K.A.2
Natt, G.3
Latzke, P.4
Heussen, N.5
Spiekermann, H.6
-
93
-
-
67650467257
-
A 3-year retrospective and clinical follow-up study of zirconia single crowns performed in a private practice
-
A. Ortorp, M.L. Kihl, and G.E. Carlsson A 3-year retrospective and clinical follow-up study of zirconia single crowns performed in a private practice Journal of Dentistry 37 2009 731 736
-
(2009)
Journal of Dentistry
, vol.37
, pp. 731-736
-
-
Ortorp, A.1
Kihl, M.L.2
Carlsson, G.E.3
-
94
-
-
77449113101
-
Zirconia posterior fixed partial dentures: A prospective clinical 3-year follow-up
-
J. Schmitt, S. Holst, M. Wichmann, S. Reich, M. Gollner, and J. Hamel Zirconia posterior fixed partial dentures: a prospective clinical 3-year follow-up International Journal of Prosthodontics 22 2009 597 603
-
(2009)
International Journal of Prosthodontics
, vol.22
, pp. 597-603
-
-
Schmitt, J.1
Holst, S.2
Wichmann, M.3
Reich, S.4
Gollner, M.5
Hamel, J.6
-
95
-
-
84859393267
-
Prognosis of zirconia ceramic fixed partial dentures: A 7-year prospective study
-
D. Lops, D. Mosca, P. Casentini, M. Ghisolfi, and E. Romeo Prognosis of zirconia ceramic fixed partial dentures: a 7-year prospective study International Journal of Prosthodontics 25 2012 21 23
-
(2012)
International Journal of Prosthodontics
, vol.25
, pp. 21-23
-
-
Lops, D.1
Mosca, D.2
Casentini, P.3
Ghisolfi, M.4
Romeo, E.5
-
96
-
-
84860241570
-
A 5-year retrospective study of survival of zirconia single crowns fitted in a private clinical setting
-
A. Ortorp, M.L. Kihl, and G.E. Carlsson A 5-year retrospective study of survival of zirconia single crowns fitted in a private clinical setting Journal of Dentistry 40 2012 527 530
-
(2012)
Journal of Dentistry
, vol.40
, pp. 527-530
-
-
Ortorp, A.1
Kihl, M.L.2
Carlsson, G.E.3
-
99
-
-
0033093435
-
Clinical examination of leucite-reinforced glass-ceramic crowns (Empress) in general practice: A retrospective study
-
G. Sjogren, R. Lantto, A. Granberg, B.O. Sundstrom, and A. Tillberg Clinical examination of leucite-reinforced glass-ceramic crowns (Empress) in general practice: a retrospective study International Journal of Prosthodontics 12 1999 122 128
-
(1999)
International Journal of Prosthodontics
, vol.12
, pp. 122-128
-
-
Sjogren, G.1
Lantto, R.2
Granberg, A.3
Sundstrom, B.O.4
Tillberg, A.5
-
100
-
-
0036652611
-
An 11-year clinical evaluation of leucite-reinforced glass-ceramic crowns: A retrospective study
-
M. Fradeani, and M. Redemagni An 11-year clinical evaluation of leucite-reinforced glass-ceramic crowns: a retrospective study Quintessence International 33 2002 503 510
-
(2002)
Quintessence International
, vol.33
, pp. 503-510
-
-
Fradeani, M.1
Redemagni, M.2
-
102
-
-
33645309086
-
Survival rates of IPS Empress 2 all-ceramic crowns and fixed partial dentures: Results of a 5-year prospective clinical study
-
P. Marquardt, and J.R. Strub Survival rates of IPS Empress 2 all-ceramic crowns and fixed partial dentures: results of a 5-year prospective clinical study Quintessence International 37 2006 253 259
-
(2006)
Quintessence International
, vol.37
, pp. 253-259
-
-
Marquardt, P.1
Strub, J.R.2
-
103
-
-
33749065120
-
Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures
-
B. Taskonak, and A. Sertgoz Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures Dental Materials 22 2006 1008 1013
-
(2006)
Dental Materials
, vol.22
, pp. 1008-1013
-
-
Taskonak, B.1
Sertgoz, A.2
-
104
-
-
42449126674
-
Four-year clinical performance of a lithia disilicate-based core ceramic for posterior fixed partial dentures
-
J.F. Esquivel-Upshaw, H. Young, J. Jones, M. Yang, and K.J. Anusavice Four-year clinical performance of a lithia disilicate-based core ceramic for posterior fixed partial dentures International Journal of Prosthodontics 21 2008 155 160
-
(2008)
International Journal of Prosthodontics
, vol.21
, pp. 155-160
-
-
Esquivel-Upshaw, J.F.1
Young, H.2
Jones, J.3
Yang, M.4
Anusavice, K.J.5
-
105
-
-
75349085723
-
Retrospective survival analysis of 261 lithium disilicate crowns in a private general practice
-
M. Valenti, and A. Valenti Retrospective survival analysis of 261 lithium disilicate crowns in a private general practice Quintessence International 40 2009 573 579
-
(2009)
Quintessence International
, vol.40
, pp. 573-579
-
-
Valenti, M.1
Valenti, A.2
-
106
-
-
75149136074
-
Three-year clinical evaluation of two ceramic crown systems: A preliminary study
-
M.K. Etman, and M.J. Woolford Three-year clinical evaluation of two ceramic crown systems: a preliminary study Journal of Prosthetic Dentistry 103 2010 80 90
-
(2010)
Journal of Prosthetic Dentistry
, vol.103
, pp. 80-90
-
-
Etman, M.K.1
Woolford, M.J.2
-
107
-
-
84856366502
-
Ten-year survival of anterior all-ceramic resin-bonded fixed dental prostheses
-
M. Kern, and M. Sasse Ten-year survival of anterior all-ceramic resin-bonded fixed dental prostheses Journal of Adhesive Dentistry 13 2011 407 410
-
(2011)
Journal of Adhesive Dentistry
, vol.13
, pp. 407-410
-
-
Kern, M.1
Sasse, M.2
-
108
-
-
84871931937
-
Clinical results of lithium disilicate crowns after up to 9 years of service
-
Published online, Accessed June 8, 2012
-
M. Gehrt, S. Wolfart, N. Rafai, S. Reich, and D. Edelhoff Clinical results of lithium disilicate crowns after up to 9 years of service Clinical Oral Investigations 2012 Published online, Accessed June 8, 2012 http://www.springerlink.com/content/nx2n675355k2p63j/
-
(2012)
Clinical Oral Investigations
-
-
Gehrt, M.1
Wolfart, S.2
Rafai, N.3
Reich, S.4
Edelhoff, D.5
|