메뉴 건너뛰기




Volumn 14, Issue , 2012, Pages 397-429

Advanced technologies for gastrointestinal endoscopy

Author keywords

Capsule; Colonoscopy; Flexible endoscopy; Magnet; Robotic capsules; Robotic endoscopy; Technology; Video capsule endoscopy; Wireless; Wireless capsule endoscopy

Indexed keywords

CAPSULE; CAPSULE ENDOSCOPY; COLONOSCOPY; FLEXIBLE ENDOSCOPY; ROBOTIC CAPSULE; WIRELESS CAPSULE ENDOSCOPY;

EID: 84864204614     PISSN: 15239829     EISSN: 15454274     Source Type: Book Series    
DOI: 10.1146/annurev-bioeng-071811-150006     Document Type: Review
Times cited : (178)

References (136)
  • 2
    • 0002063410 scopus 로고
    • A flexible fiberscope, using static scanning
    • Hopkins HH, Kapany NS. 1954. A flexible fiberscope, using static scanning. Nature 173:39-41
    • (1954) Nature , vol.173 , pp. 39-41
    • Hopkins, H.H.1    Kapany, N.S.2
  • 3
    • 79952061753 scopus 로고    scopus 로고
    • The colorectal cancer control program: Partnering to increase population level screening
    • Joseph DA, DeGroff AS, HayesNS, Wong FL, Plescia M. 2011. The colorectal cancer control program: partnering to increase population level screening. Gastrointest. Endosc. 73(3):429-34
    • (2011) Gastrointest. Endosc. , vol.73 , Issue.3 , pp. 429-434
    • Joseph, D.A.1    Degroff, A.S.2    Hayesns Wong, F.L.3    Plescia, M.4
  • 6
    • 84875242319 scopus 로고    scopus 로고
    • Nat. Dig. Dis. Inf. Clgh., NIH Publ. No. 10-3873
    • Nat. Dig. Dis. Inf. Clgh. 2010. Digestive diseases statistics for the United States. NIH Publ. No. 10-3873. http://digestive.niddk.nih.gov/statistics/ statistics.aspx
    • (2010) Digestive Diseases Statistics for the United States
  • 10
    • 14544287404 scopus 로고    scopus 로고
    • Meckel diverticulum: The Mayo Clinic experience with 1476 patients (1950-2002)
    • DOI 10.1097/01.sla.0000154270.14308.5f
    • Park JJ, Wolff BG, Tollefson MK, Walsh EE, Larson DR. 2005. Meckel diverticulum: theMayo Clinic experience with 1476 patients (1950-2002). Ann. Surg. 241:529-33 (Pubitemid 40299732)
    • (2005) Annals of Surgery , vol.241 , Issue.3 , pp. 529-533
    • Park, J.J.1    Wolff, B.G.2    Tollefson, M.K.3    Walsh, E.E.4    Larson, D.R.5
  • 11
    • 0031650290 scopus 로고    scopus 로고
    • Preparation of patients for gastrointestinal endoscopy
    • Am. Soc. Gastrointest. Endos.
    • Am. Soc. Gastrointest. Endos. 1998. Preparation of patients for gastrointestinal endoscopy. Gastrointest. Endosc. 48:691-94
    • (1998) Gastrointest. Endosc. , vol.48 , pp. 691-694
  • 13
    • 67650169924 scopus 로고    scopus 로고
    • Barriers to colorectal cancer screening: A case-control study
    • Cai SR, Zhang SZ, Zhu HH, Zheng S. 2009. Barriers to colorectal cancer screening: a case-control study. World J. Gastroenterol. 15(20):2531-36
    • (2009) World J. Gastroenterol. , vol.15 , Issue.20 , pp. 2531-2536
    • Cai, S.R.1    Zhang, S.Z.2    Zhu, H.H.3    Zheng, S.4
  • 16
    • 78049338868 scopus 로고    scopus 로고
    • Randomized comparison of 3 different-sized biopsy forceps for quality of sampling in Barrett's esophagus
    • Gonzalez S, Yu WM, Smith MS, Slack KN, Rotterdam H, et al. 2010. Randomized comparison of 3 different-sized biopsy forceps for quality of sampling in Barrett's esophagus. Gastrointest. Endosc. 72:935-40
    • (2010) Gastrointest. Endosc. , vol.72 , pp. 935-940
    • Gonzalez, S.1    Yu, W.M.2    Smith, M.S.3    Slack, K.N.4    Rotterdam, H.5
  • 20
    • 0035458872 scopus 로고    scopus 로고
    • Complications of diagnostic and therapeutic colonoscopy within a defined population in Sweden
    • DOI 10.1067/mge.2001.117545
    • Dafnis G, Ekbom A, Pahlman L, Blomqvist P. 2001. Complication of diagnostic and therapeutic colonoscopy within a defined population in Sweden. Gastrointest. Endosc. 54:302-9 (Pubitemid 33665508)
    • (2001) Gastrointestinal Endoscopy , vol.54 , Issue.3 , pp. 302-309
    • Dafnis, G.1    Ekbom, A.2    Pahlman, L.3    Blomqvist, P.4
  • 21
    • 79952492150 scopus 로고    scopus 로고
    • Scopes too flexible. . . and Too Stiff
    • Loeve A, Breedveld P, Dankelman J. 2010. Scopes too flexible. . . and too stiff. IEEE Pulse 1(3):26-41
    • (2010) IEEE Pulse , vol.1 , Issue.3 , pp. 26-41
    • Loeve, A.1    Breedveld, P.2    Dankelman, J.3
  • 23
    • 41049105968 scopus 로고    scopus 로고
    • An adequate level of training for technical competence in screening and diagnostic colonoscopy: A prospectivemulticenter evaluation of the learning curve
    • Lee SH, Chung IK, Kim SJ, Kim JO, Ko BM, et al. 2008. An adequate level of training for technical competence in screening and diagnostic colonoscopy: a prospectivemulticenter evaluation of the learning curve. Gastrointest. Endosc. 67(4):683-89
    • (2008) Gastrointest. Endosc. , vol.67 , Issue.4 , pp. 683-689
    • Lee, S.H.1    Chung, I.K.2    Kim, S.J.3    Kim, J.O.4    Ko, B.M.5
  • 25
    • 32244449015 scopus 로고    scopus 로고
    • Virtual colonoscopy in the detection of colonic polyps and neoplasms
    • DOI 10.1016/j.bpg.2005.08.004, PII S1521691805001150, Advances in Imaging of the Gastrointestinal Trct
    • O'Hare A, Fenlon H. 2006. Virtual colonoscopy in the detection of colonic polyps and neoplasm. Best Pract. Res. Clin. Gastroenterol. 20:79-92 (Pubitemid 43210628)
    • (2006) Best Practice and Research: Clinical Gastroenterology , vol.20 , Issue.1 , pp. 79-92
    • O'Hare, A.1    Fenlon, H.2
  • 27
    • 78549239198 scopus 로고    scopus 로고
    • Computed tomographic colonography: Ready for prime time?
    • Rockey DC. 2010. Computed tomographic colonography: ready for prime time? Gastroenterol. Clin. N. Am. 39(4):901-9
    • (2010) Gastroenterol. Clin. N. Am. , vol.39 , Issue.4 , pp. 901-909
    • Rockey, D.C.1
  • 28
    • 0010723705 scopus 로고    scopus 로고
    • US Prev. Serv. Task Force.
    • US Prev. Serv. Task Force. 2008. Screening for colorectal cancer. http://www.uspreventiveservicestaskforce.org/uspstf/uspscolo.htm
    • (2008) Screening for Colorectal Cancer
  • 30
    • 33344477634 scopus 로고    scopus 로고
    • The Aer-O-Scope: Proof of concept of a pneumatic, skill-independent, self-propelling, self-navigating colonoscope
    • DOI 10.1053/j.gastro.2005.12.018, PII S001650850502528X
    • Vucelic B, Rex D, Pulanic R, Pfefer J, Hrstic I, et al. 2006. The Aer-O-Scope: proof of concept of a pneumatic, skill-independent, self-propelling, self-navigating colonoscope. Gastroenterology 130(3):672-77 (Pubitemid 43374517)
    • (2006) Gastroenterology , vol.130 , Issue.3 , pp. 672-677
    • Vucelic, B.1    Rex, D.2    Pulanic, R.3    Pfefer, J.4    Hrstic, I.5    Levin, B.6    Halpern, Z.7    Arber, N.8
  • 33
    • 44349191500 scopus 로고    scopus 로고
    • A motor-driven single-use colonoscope controlled with a hand-held device: As feasibility study in volunteers
    • DOI 10.1016/j.gie.2007.10.065, PII S0016510707030532
    • Rösch T, Adler A, PohlH, Wettschureck E, KochM, et al. 2008. Amotor-driven single-use colonoscope controlled with a hand-held device: a feasibility study in volunteers. Gastrointest. Endosc. 67(7):1139-46 (Pubitemid 351728110)
    • (2008) Gastrointestinal Endoscopy , vol.67 , Issue.7 , pp. 1139-1146
    • Rosch, T.1    Adler, A.2    Pohl, H.3    Wettschureck, E.4    Koch, M.5    Wiedenmann, B.6    Hoepffner, N.7
  • 34
    • 79958012679 scopus 로고    scopus 로고
    • High cecal intubation rateswith a new computer-assisted colonoscope: A feasibility study
    • Groth S, Rex DK, Rösch T, Hoepffner N. 2011. High cecal intubation rateswith a new computer-assisted colonoscope: a feasibility study. Am. J. Gastroenterol. 106:1075-80
    • (2011) Am. J. Gastroenterol. , vol.106 , pp. 1075-1080
    • Groth, S.1    Rex, D.K.2    Rösch, T.3    Hoepffner, N.4
  • 35
    • 53149122276 scopus 로고    scopus 로고
    • Sightline ColonoSight system for a disposable, power-assisted, non-fiber-optic colonoscopy (with video)
    • Shike M, Fireman Z, Eliakim R, Segol O, Sloyer A, et al. 2008. Sightline ColonoSight system for a disposable, power-assisted, non-fiber-optic colonoscopy (with video). Gastrointest. Endosc. 68(4):701-10
    • (2008) Gastrointest. Endosc. , vol.68 , Issue.4 , pp. 701-710
    • Shike, M.1    Fireman, Z.2    Eliakim, R.3    Segol, O.4    Sloyer, A.5
  • 36
    • 84863530054 scopus 로고    scopus 로고
    • Magnetic air capsule robotic system: Proof of concept of a novel approach for painless colonoscopy
    • Valdastri P, Ciuti G, Verbeni A, Menciassi A, Dario P, et al. 2012. Magnetic air capsule robotic system: proof of concept of a novel approach for painless colonoscopy. Surg. Endosc. 26(5):1238-46
    • (2012) Surg. Endosc. , vol.26 , Issue.5 , pp. 1238-1246
    • Valdastri, P.1    Ciuti, G.2    Verbeni, A.3    Menciassi, A.4    Dario, P.5
  • 38
    • 84857038067 scopus 로고    scopus 로고
    • Evaluation of magnetic scope navigation in screening endoscopic examination of colorectal cancer
    • Szura M, Bucki K, Matyja A, Kulig J. 2012. Evaluation of magnetic scope navigation in screening endoscopic examination of colorectal cancer. Surg. Endosc. 26:632-38
    • (2012) Surg. Endosc. , vol.26 , pp. 632-638
    • Szura, M.1    Bucki, K.2    Matyja, A.3    Kulig, J.4
  • 39
    • 77957299548 scopus 로고    scopus 로고
    • A novel device for rapid cleaning of poorly prepared colons
    • Moshkowitz M, Hirsch Y, Carmel I, Duvdevany T, Fabian I, et al. 2010. A novel device for rapid cleaning of poorly prepared colons. Endoscopy 42(10):834-36
    • (2010) Endoscopy , vol.42 , Issue.10 , pp. 834-836
    • Moshkowitz, M.1    Hirsch, Y.2    Carmel, I.3    Duvdevany, T.4    Fabian, I.5
  • 40
    • 29244452600 scopus 로고    scopus 로고
    • Colon cleaning during colonoscopy: A new mechanical cleaning device tested in a porcine model
    • DOI 10.1016/j.gie.2005.05.023, PII S001651070502105X
    • Fritscher-Ravens A, Mosse CA, Mills T, Ikeda K, Swain P. 2006. Colon cleaning during colonoscopy: a new mechanical cleaning device tested in a porcine model. Gastrointest. Endosc. 63:141-43 (Pubitemid 41827793)
    • (2006) Gastrointestinal Endoscopy , vol.63 , Issue.1 , pp. 141-143
    • Fritscher-Ravens, A.1    Mosse, C.A.2    Mills, T.3    Ikeda, K.4    Swain, P.5
  • 42
    • 0036895017 scopus 로고    scopus 로고
    • Colonoscopic miss rates determined by direct comparison of colonoscopy with colon resection specimens
    • Postic G, Lewin D, Bickerstaff C, Wallace MB. 2002. Colonoscopic miss rates determined by direct comparison of colonoscopy with colon resection specimens. Am. J. Gastroenterol. 97(12):3182-8543. Sauk J, Itzkowitz S.
    • (2002) Am. J. Gastroenterol. , vol.97 , Issue.12 , pp. 3182-8543
    • Postic, G.1    Lewin, D.2    Bickerstaff, C.3    Wallace, M.B.4
  • 43
    • 79952707882 scopus 로고    scopus 로고
    • Optical enhancements in diagnosis and surveillance of colorectal neoplasia
    • Sauk J, Itzkowitz S. 2011. Optical enhancements in diagnosis and surveillance of colorectal neoplasia. Curr. Colorectal Cancer Rep. 7:24-32
    • (2011) Curr. Colorectal Cancer Rep. , vol.7 , pp. 24-32
    • Sauk, J.1    Itzkowitz, S.2
  • 44
    • 84857918102 scopus 로고    scopus 로고
    • Comparison of the yield and miss rate of narrow band imaging and white light endoscopy in patients undergoing screening or surveillance colonoscopy: A meta-analysis
    • Pasha SF, Leighton JA, Das A, HarrisonME, Gurudu SR, et al. 2012. Comparison of the yield and miss rate of narrow band imaging and white light endoscopy in patients undergoing screening or surveillance colonoscopy: a meta-analysis. Am. J. Gastroenterol. 107:363-70
    • (2012) Am. J. Gastroenterol. , vol.107 , pp. 363-370
    • Pasha, S.F.1    Leighton, J.A.2    Das, A.3    Harrison, M.E.4    Gurudu, S.R.5
  • 45
    • 80053654631 scopus 로고    scopus 로고
    • High definition colonoscopy vs. standard video endoscopy for the detection of colonic polyps: A meta-analysis
    • Subramanian V, Mannath J, Hawkey CJ, Ragunath K. 2011. High definition colonoscopy vs. standard video endoscopy for the detection of colonic polyps: a meta-analysis. Endoscopy 43:499-505
    • (2011) Endoscopy , vol.43 , pp. 499-505
    • Subramanian, V.1    Mannath, J.2    Hawkey, C.J.3    Ragunath, K.4
  • 47
    • 77951644132 scopus 로고    scopus 로고
    • Advances in endoscopic imaging of colorectal neoplasia
    • Wallace MB, Kiesslich R. 2010. Advances in endoscopic imaging of colorectal neoplasia. Gastroenterology 138(6):2140-50
    • (2010) Gastroenterology , vol.138 , Issue.6 , pp. 2140-2150
    • Wallace, M.B.1    Kiesslich, R.2
  • 49
    • 77950594393 scopus 로고    scopus 로고
    • Comparison of a new PillCamTM SB2 video capsule versus the standard PillCamTM SB for detection of small bowel disease
    • Metzger YC, Adler SN, Bar-Gil Shitrit A, Koslowsky B, Bjarnason I. 2009. Comparison of a new PillCamTM SB2 video capsule versus the standard PillCamTM SB for detection of small bowel disease. Rep. Med. Imaging 2:7-11
    • (2009) Rep. Med. Imaging , vol.2 , pp. 7-11
    • Metzger, Y.C.1    Adler, S.N.2    Bar-Gil Shitrit, A.3    Koslowsky, B.4    Bjarnason, I.5
  • 51
    • 58649097129 scopus 로고    scopus 로고
    • First clinical trial of the "MiRo" capsule endoscope by using a novel transmission technology: Electric-field propagation
    • Bang S, Park J, Jeong S, Kim Y, ShimHB, et al. 2009. First clinical trial of the "MiRo" capsule endoscope by using a novel transmission technology: electric-field propagation. Gastrointest. Endosc. 69:253-59
    • (2009) Gastrointest. Endosc. , vol.69 , pp. 253-259
    • Bang, S.1    Park, J.2    Jeong, S.3    Shimhb, K.Y.4
  • 52
    • 77953482255 scopus 로고    scopus 로고
    • Fields of applications, diagnostic yields and findings of OMOM capsule endoscopy in 2400 Chinese patients
    • Liao Z, Gao R, Li F, Xu C, Zhou Y, et al. 2010. Fields of applications, diagnostic yields and findings of OMOM capsule endoscopy in 2400 Chinese patients. World J. Gastroenterol. 16(21):2669
    • (2010) World J. Gastroenterol. , vol.16 , Issue.21 , pp. 2669
    • Liao, Z.1    Gao, R.2    Li, F.3    Xu, C.4    Zhou, Y.5
  • 54
    • 50949104729 scopus 로고    scopus 로고
    • Safety, reliability and limitations of the given patency capsule in patients at risk of capsule retention: A 3-year technical review
    • Postgate AJ, Burling D, Gupta A, Fitzpatrick A, Fraser C. 2008. Safety, reliability and limitations of the given patency capsule in patients at risk of capsule retention: a 3-year technical review. Dig. Dis. Sci. 53(10):2732-38
    • (2008) Dig. Dis. Sci. , vol.53 , Issue.10 , pp. 2732-2738
    • Postgate, A.J.1    Burling, D.2    Gupta, A.3    Fitzpatrick, A.4    Fraser, C.5
  • 55
    • 76349101674 scopus 로고    scopus 로고
    • Diagnostic accuracy of esophageal capsule endoscopy versus conventional upper digestive endoscopy for suspected esophageal squamous cell carcinoma
    • Heresbach D, Leray E, d'Halluin PN, Cholet F, Lapalus MG, et al. 2010. Diagnostic accuracy of esophageal capsule endoscopy versus conventional upper digestive endoscopy for suspected esophageal squamous cell carcinoma. Endoscopy 42(2):93-97
    • (2010) Endoscopy , vol.42 , Issue.2 , pp. 93-97
    • Heresbach, D.1    Leray, E.2    D'halluin, P.N.3    Cholet, F.4    Lapalus, M.G.5
  • 56
    • 77749328946 scopus 로고    scopus 로고
    • European Society of Gastrointestinal Endoscopy (ESGE): Recommendations (2009) on clinical use of video capsule endoscopy to investigate small-bowel, esophageal and colonic diseases
    • Ladas SD, Triantafyllou K, Spada C, Riccioni ME, Rey JF, et al. 2010. European Society of Gastrointestinal Endoscopy (ESGE): recommendations (2009) on clinical use of video capsule endoscopy to investigate small-bowel, esophageal and colonic diseases. Endoscopy 42(3):220-27
    • (2010) Endoscopy , vol.42 , Issue.3 , pp. 220-227
    • Ladas, S.D.1    Triantafyllou, K.2    Spada, C.3    Riccioni, M.E.4    Rey, J.F.5
  • 58
  • 59
    • 71649104121 scopus 로고    scopus 로고
    • Design of a 2 Mbps FSK near-field transmitter for wireless capsule endoscopy
    • Thoné J, Radiom S, Turgis D, Carta R, Gielen G, Puers R. 2009. Design of a 2 Mbps FSK near-field transmitter for wireless capsule endoscopy. Sens. Actuators A 156(1):43-48
    • (2009) Sens. Actuators A , vol.156 , Issue.1 , pp. 43-48
    • Thoné, J.1    Radiom, S.2    Turgis, D.3    Carta, R.4    Gielen, G.5    Puers, R.6
  • 60
    • 33644936402 scopus 로고    scopus 로고
    • An ultra-low-power image compressor for capsule endoscope
    • Lin MC, Dung LR, Weng PK. 2006. An ultra-low-power image compressor for capsule endoscope. Biomed. Eng. Online 5:14
    • (2006) Biomed. Eng. Online , vol.5 , pp. 14
    • Lin, M.C.1    Dung, L.R.2    Weng, P.K.3
  • 61
    • 78649950985 scopus 로고    scopus 로고
    • A novel JPEG-based wireless capsule endoscope
    • Pan G, Yan G, Qiu X, Song X. 2010. A novel JPEG-based wireless capsule endoscope. Biomed. Instrum. Technol. 44(6):519-22
    • (2010) Biomed. Instrum. Technol. , vol.44 , Issue.6 , pp. 519-522
    • Pan, G.1    Yan, G.2    Qiu, X.3    Song, X.4
  • 62
    • 47849116075 scopus 로고    scopus 로고
    • Hardware implementation aspects of new low complexity image coding algorithm for wireless capsule endoscopy
    • Turcza P, Zieliński T, Duplaga M. 2008. Hardware implementation aspects of new low complexity image coding algorithm for wireless capsule endoscopy. Lect. Notes Comput. Sci. 5101:476-85
    • (2008) Lect. Notes Comput. Sci. , vol.5101 , pp. 476-485
    • Turcza, P.1    Zieliński, T.2    Duplaga, M.3
  • 63
    • 79956355269 scopus 로고    scopus 로고
    • A wideband spiral antenna for ingestible capsule endoscope systems: Experimental results in a human phantom and a pig
    • Lee S, Lee J, Yoon Y, Park S, Cheon C, et al. 2011. A wideband spiral antenna for ingestible capsule endoscope systems: experimental results in a human phantom and a pig. IEEE Trans. Biomed. Eng. 58:1734-41
    • (2011) IEEE Trans. Biomed. Eng. , vol.58 , pp. 1734-1741
    • Lee, S.1    Lee, J.2    Yoon, Y.3    Park, S.4    Cheon, C.5
  • 66
    • 82755189714 scopus 로고    scopus 로고
    • An FPGA-based versatile development system for endoscopic capsule design optimization
    • Cavallotti C, Merlino P, Vatteroni M, Valdastri P, Abramo A, et al. 2011. An FPGA-based versatile development system for endoscopic capsule design optimization. Sens. Actuators A 172(1):301-7
    • (2011) Sens. Actuators A , vol.172 , Issue.1 , pp. 301-307
    • Cavallotti, C.1    Merlino, P.2    Vatteroni, M.3    Valdastri, P.4    Abramo, A.5
  • 67
    • 78649515205 scopus 로고    scopus 로고
    • A wireless narrowband imaging chip for capsule endoscope
    • Dung LR, Wu YY. 2010. A wireless narrowband imaging chip for capsule endoscope. IEEE Trans. Biomed. Circuits Syst. 4(6):462-68
    • (2010) IEEE Trans. Biomed. Circuits Syst. , vol.4 , Issue.6 , pp. 462-468
    • Dung, L.R.1    Wu, Y.Y.2
  • 68
    • 85008018894 scopus 로고    scopus 로고
    • A multishutter time sensor for multispectral imaging in a 3-D reconstruction integrated sensor
    • Kolar A, Pinna A, Romain O, Viateur S, Ea T, et al. 2009. A multishutter time sensor for multispectral imaging in a 3-D reconstruction integrated sensor. IEEE Sens. J. 9(4):478-84
    • (2009) IEEE Sens. J. , vol.9 , Issue.4 , pp. 478-484
    • Kolar, A.1    Pinna, A.2    Romain, O.3    Viateur, S.4    Ea, T.5
  • 70
    • 77952994843 scopus 로고    scopus 로고
    • A magnetic internal mechanism for precise orientation of the camera in wireless endoluminal applications
    • Valdastri P, Quaglia C, Buselli E, Arezzo A, Di Lorenzo N, et al. 2010. A magnetic internal mechanism for precise orientation of the camera in wireless endoluminal applications. Endoscopy 42(6):481-86
    • (2010) Endoscopy , vol.42 , Issue.6 , pp. 481-486
    • Valdastri, P.1    Quaglia, C.2    Buselli, E.3    Arezzo, A.4    Di Lorenzo, N.5
  • 71
    • 84864190613 scopus 로고    scopus 로고
    • A strategy to abstract WCE video clips based on LDA
    • May 9-13, Shanghai. Piscataway, NJ: IEEE
    • Zhao Q, Meng MQH. 2011. A strategy to abstract WCE video clips based on LDA. Proc. IEEE Conf. Robot. Autom. (ICRA '11), May 9-13, Shanghai, pp. 4145-50. Piscataway, NJ: IEEE
    • (2011) Proc. IEEE Conf. Robot. Autom. (ICRA '11) , pp. 4145-4150
    • Zhao, Q.1    Meng, M.Q.H.2
  • 73
    • 62549152628 scopus 로고    scopus 로고
    • A model of deformable rings for interpretation of wireless capsule endoscopic videos
    • Szczypinski PM, Sriram RD, Sriram PVJ, Reddy DN. 2009. A model of deformable rings for interpretation of wireless capsule endoscopic videos. Med. Image Anal. 13(2):312-24
    • (2009) Med. Image Anal. , vol.13 , Issue.2 , pp. 312-324
    • Szczypinski, P.M.1    Sriram, R.D.2    Pvj, S.3    Reddy, D.N.4
  • 74
    • 78650823724 scopus 로고    scopus 로고
    • 3D reconstruction of wireless capsule endoscopy images
    • Aug. 31-Sept. 4, Buenos Aires, Piscataway, NJ: IEEE
    • Fan Y, Meng MQH, Li B. 2010. 3D reconstruction of wireless capsule endoscopy images. Proc. 32nd Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., Aug. 31-Sept. 4, Buenos Aires, pp. 5149-52. Piscataway, NJ: IEEE
    • (2010) Proc. 32nd Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. , pp. 5149-5152
    • Fan, Y.1    Meng, M.Q.H.2    Li, B.3
  • 77
    • 0013780795 scopus 로고
    • Heidelberg capsule: I. in vitro evaluation of a new instrument for measuring intragastric pH
    • SteinbergWH, Mina FA, Pick PG, Frey GH. 1965. Heidelberg capsule: I. In vitro evaluation of a new instrument for measuring intragastric pH. J. Pharm. Sci. 54(5):772-76
    • (1965) J. Pharm. Sci. , vol.54 , Issue.5 , pp. 772-776
    • Steinberg, W.H.1    Mina, F.A.2    Pick, P.G.3    Frey, G.H.4
  • 80
    • 79953005262 scopus 로고    scopus 로고
    • An intelligent electronic capsule system for automated detection of gastrointestinal bleeding
    • Liu H, Wang G, Wei K, Pi XT, Zhu L, et al. 2010. An intelligent electronic capsule system for automated detection of gastrointestinal bleeding. J. Zhejiang Univ. Sci. B 11(12):937-43
    • (2010) J. Zhejiang Univ. Sci. B , vol.11 , Issue.12 , pp. 937-943
    • Liu, H.1    Wang, G.2    Wei, K.3    Pi, X.T.4    Zhu, L.5
  • 82
    • 80052074152 scopus 로고    scopus 로고
    • Characterization of the electrochemical behavior of gastrointestinal fluids using a multielectrode sensor probe
    • Twomey K, Alvarez de Eulate E, Marchesi JR, Kolida S, Gibson G, et al. 2011. Characterization of the electrochemical behavior of gastrointestinal fluids using a multielectrode sensor probe. IEEE Trans. Biomed. Eng. 58(9):2521-27
    • (2011) IEEE Trans. Biomed. Eng. , vol.58 , Issue.9 , pp. 2521-2527
    • Twomey, K.1    Alvarez De Eulate, E.2    Marchesi, J.R.3    Kolida, S.4    Gibson, G.5
  • 84
    • 34047106904 scopus 로고    scopus 로고
    • A localization method using 3-axis magnetoresistive sensors for tracking of capsule endoscope
    • DOI 10.1109/IEMBS.2006.260711, 4029877, 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06
    • Wang X, Meng MQH, Hu C. 2006. A localization method using 3-axis magnetoresistive sensors for tracking of capsule endoscope. Proc. 28th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., Aug. 30-Sept. 3, New York, N.Y., pp. 2522-25. Piscataway, NJ: IEEE (Pubitemid 46520420)
    • (2006) Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings , pp. 2522-2525
    • Wang, X.1    Meng, M.Q.-H.2    Hu, C.3
  • 86
    • 38149025437 scopus 로고    scopus 로고
    • Wearable magnetic locating and tracking system for MEMS medical capsule
    • Wu X, HouW, Peng C, Zheng X, Fang X, He J. 2008. Wearable magnetic locating and tracking system for MEMS medical capsule. Sens. Actuators A 141(2):432-39
    • (2008) Sens. Actuators A , vol.141 , Issue.2 , pp. 432-439
    • Wu, X.1    Houw Peng, C.2    Zheng, X.3    Fang, X.4    He, J.5
  • 87
    • 33751059312 scopus 로고    scopus 로고
    • Capsule tracking in the GI tract: A novel microcontroller based solution
    • 1634269, Proceedings of the 2006 IEEE Sensors Applications Symposium
    • Arshak K, Adepoju F. 2006. Capsule tracking in the GI tract: a novel microcontroller based solution. Proc. 2006 IEEE Sens. Appl. Symp., Feb. 7-9, Houston, Tex., pp. 186-91. Piscataway, NJ: IEEE (Pubitemid 44754605)
    • (2006) Proceedings of the 2006 IEEE Sensors Applications Symposium , pp. 186-191
    • Arshak, K.1    Adepoju, F.2
  • 88
    • 77949422045 scopus 로고    scopus 로고
    • Robotic magnetic steering and locomotion of capsule endoscope for diagnostic and surgical endoluminal procedures
    • Ciuti G, Valdastri P, Menciassi A, Dario P. 2010. Robotic magnetic steering and locomotion of capsule endoscope for diagnostic and surgical endoluminal procedures. Robotica 28(2):199-207
    • (2010) Robotica , vol.28 , Issue.2 , pp. 199-207
    • Ciuti, G.1    Valdastri, P.2    Menciassi, A.3    Dario, P.4
  • 90
    • 35348881151 scopus 로고    scopus 로고
    • Automatic classification of digestive organs in wireless capsule endoscopy videos
    • DOI 10.1145/1244002.1244230, Proceedings of the 2007 ACM Symposium on Applied Computing
    • Lee J, Oh J, Shah SK, Yuan X, Tang SJ. 2007. Automatic classification of digestive organs in wireless endoscopy videos. Proc. ACMSymp. Appl. Comput., Mar. 11-15, Seoul, pp. 1041-45. New York: Assoc. Comput. Mach. (Pubitemid 47569941)
    • (2007) Proceedings of the ACM Symposium on Applied Computing , pp. 1041-1045
    • Lee, J.1    Oh, J.2    Shah, S.K.3    Yuan, X.4    Tang, S.J.5
  • 91
    • 84867334830 scopus 로고    scopus 로고
    • A wireless module for vibratory motor control and inertial sensing in capsule endoscopy
    • In press, doi: 10.1016/j.sna.2011.12.024
    • Ciuti G, Pateromichelakis N, Sfakiotakis M, Valdastri P, Menciassi A, et al. 2012. A wireless module for vibratory motor control and inertial sensing in capsule endoscopy. Sens. Actuators A In press, doi: 10.1016/j.sna.2011.12.024
    • (2012) Sens. Actuators A
    • Ciuti, G.1    Pateromichelakis, N.2    Sfakiotakis, M.3    Valdastri, P.4    Menciassi, A.5
  • 93
    • 49249105857 scopus 로고    scopus 로고
    • Structure optimization of the endoscopic robot ciliary leg based on dimensional analysis
    • Dec. 15-18, Sanya, China. Piscataway, NJ: IEEE
    • Feng Y, Li W, Li M, Sun L. 2007. Structure optimization of the endoscopic robot ciliary leg based on dimensional analysis. Proc. IEEE Int. Conf. Robot. Biomim., Dec. 15-18, Sanya, China, pp. 109-14. Piscataway, NJ: IEEE
    • (2007) Proc. IEEE Int. Conf. Robot. Biomim. , pp. 109-114
    • Feng, Y.1    Li, W.2    Li, M.3    Sun, L.4
  • 95
    • 34250678873 scopus 로고    scopus 로고
    • An inchworm-like locomotion mechanism based on magnetic actuator for active capsule endoscope
    • DOI 10.1109/IROS.2006.281887, 4058543, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems, IROS 2006
    • Wang X, Meng MQH. 2006. An inchworm-like locomotion mechanism based on magnetic actuator for active capsule endoscope. Proc. IEEE/RSJ Int. Conf. Intell. Robots Syst., Oct. 9-15, Beijing, pp. 1267-72. Piscataway, NJ: IEEE (Pubitemid 46928070)
    • (2006) IEEE International Conference on Intelligent Robots and Systems , pp. 1267-1272
    • Wang, X.1    Meng, M.Q.-H.2
  • 96
    • 84862704610 scopus 로고    scopus 로고
    • Capsular microrobot using directional friction spiral
    • May 12-17, Kobe, Jpn., Piscataway, NJ: IEEE
    • Yim S, Jeona D. 2009. Capsular microrobot using directional friction spiral. Proc. IEEE Conf. Robot. Autom. (ICRA '09), May 12-17, Kobe, Jpn., pp. 4444-49. Piscataway, NJ: IEEE
    • (2009) Proc. IEEE Conf. Robot. Autom. (ICRA '09) , pp. 4444-4449
    • Yim, S.1    Jeona, D.2
  • 97
    • 77955699733 scopus 로고    scopus 로고
    • Active locomotion of a paddling-based capsule endoscope in an in vitro and in vivo experiment (with videos)
    • Kim HM, Yang S, Kim J, Park S, Cho JH, et al. 2010. Active locomotion of a paddling-based capsule endoscope in an in vitro and in vivo experiment (with videos). Gastrointest. Endosc. 72(2):381-87
    • (2010) Gastrointest. Endosc. , vol.72 , Issue.2 , pp. 381-387
    • Kim, H.M.1    Yang, S.2    Kim, J.3    Park, S.4    Cho, J.H.5
  • 99
  • 101
    • 58149271167 scopus 로고    scopus 로고
    • A legged anchoring mechanism for capsule endoscopes using micropatterned adhesives
    • Glass P, Cheung E, Sitti M. 2008. A legged anchoring mechanism for capsule endoscopes using micropatterned adhesives. IEEE Trans. Biomed. Eng. 55(12):2759-67
    • (2008) IEEE Trans. Biomed. Eng. , vol.55 , Issue.12 , pp. 2759-2767
    • Glass, P.1    Cheung, E.2    Sitti, M.3
  • 104
    • 71649092073 scopus 로고    scopus 로고
    • A miniaturized wireless control platform for robotic capsular endoscopy using advanced pseudokernel approach
    • Susilo E, Valdastri P, Menciassi A, Dario P. 2009. A miniaturized wireless control platform for robotic capsular endoscopy using advanced pseudokernel approach. Sens. Actuators A 156(1):49-58
    • (2009) Sens. Actuators A , vol.156 , Issue.1 , pp. 49-58
    • Susilo, E.1    Valdastri, P.2    Menciassi, A.3    Dario, P.4
  • 107
    • 77950593244 scopus 로고    scopus 로고
    • Design, fabrication, and testing of a capsule with hybrid locomotion for gastrointestinal tract exploration
    • Simi M, Valdastri P, Quaglia C, Menciassi A, Dario P. 2010. Design, fabrication, and testing of a capsule with hybrid locomotion for gastrointestinal tract exploration. IEEE/ASME Trans. Mechatron. 15(2):170-80
    • (2010) IEEE/ASME Trans. Mechatron. , vol.15 , Issue.2 , pp. 170-180
    • Simi, M.1    Valdastri, P.2    Quaglia, C.3    Menciassi, A.4    Dario, P.5
  • 108
    • 78651506596 scopus 로고    scopus 로고
    • Control electronics integration toward endoscopic capsule robot performing legged locomotion and illumination
    • Oct. 18-22, Taipei, Piscataway, NJ: IEEE
    • Alonso O, Freixas L, Canals J, Susilo E, Diegeuez A. 2008. Control electronics integration toward endoscopic capsule robot performing legged locomotion and illumination. Proc. IEEE/RSJ Int. Conf. Intell. Robots Syst., Oct. 18-22, Taipei, pp. 2798-803. Piscataway, NJ: IEEE
    • (2008) Proc. IEEE/RSJ Int. Conf. Intell. Robots Syst. , pp. 2798-2803
    • Alonso, O.1    Freixas, L.2    Canals, J.3    Susilo, E.4    Diegeuez, A.5
  • 112
    • 79551570334 scopus 로고    scopus 로고
    • Magnetically controllable gastrointestinal steering of video capsules
    • Carpi F, Kastelein N, Talcott M, Pappone C. 2011. Magnetically controllable gastrointestinal steering of video capsules. IEEE Trans. Biomed. Eng. 58(2):231-34
    • (2011) IEEE Trans. Biomed. Eng. , vol.58 , Issue.2 , pp. 231-234
    • Carpi, F.1    Kastelein, N.2    Talcott, M.3    Pappone, C.4
  • 113
    • 78650534654 scopus 로고    scopus 로고
    • Inspection of the human stomach using remote-controlled capsule endoscopy: A feasibility study in healthy volunteers (with videos)
    • Keller J, Fibbe C, Volke F, Gerber J, Mosse AC, et al. 2011. Inspection of the human stomach using remote-controlled capsule endoscopy: a feasibility study in healthy volunteers (with videos). Gastrointest. Endosc. 73(1):22-28
    • (2011) Gastrointest. Endosc. , vol.73 , Issue.1 , pp. 22-28
    • Keller, J.1    Fibbe, C.2    Volke, F.3    Gerber, J.4    Mosse, A.C.5
  • 114
    • 84855855944 scopus 로고    scopus 로고
    • Blinded nonrandomized comparative study of gastric examination with a magnetically guided capsule endoscope and standard videoendoscope
    • Rey JF, Ogata H, Hosoe N, Ohtsuka K, Ogata N, et al. 2012. Blinded nonrandomized comparative study of gastric examination with a magnetically guided capsule endoscope and standard videoendoscope. Gastrointest. Endosc. 75(2):373-81
    • (2012) Gastrointest. Endosc. , vol.75 , Issue.2 , pp. 373-381
    • Rey, J.F.1    Ogata, H.2    Hosoe, N.3    Ohtsuka, K.4    Ogata, N.5
  • 115
    • 76349086056 scopus 로고    scopus 로고
    • Robotic versus manual control in magnetic steering of an endoscopic capsule
    • Ciuti G, Donlin R, Valdastri P, Arezzo A, Menciassi A, et al. 2010. Robotic versus manual control in magnetic steering of an endoscopic capsule. Endoscopy 42(2):148-52
    • (2010) Endoscopy , vol.42 , Issue.2 , pp. 148-152
    • Ciuti, G.1    Donlin, R.2    Valdastri, P.3    Arezzo, A.4    Menciassi, A.5
  • 116
    • 70349783406 scopus 로고    scopus 로고
    • Diamagnetically stabilized levitation control of an intraluminal magnetic capsule
    • Lam M, Mintchev M. 2009. Diamagnetically stabilized levitation control of an intraluminal magnetic capsule. Physiol. Meas. 30:763-77
    • (2009) Physiol. Meas. , vol.30 , pp. 763-777
    • Lam, M.1    Mintchev, M.2
  • 117
    • 77957602132 scopus 로고    scopus 로고
    • In vivo trial of a driving system for a self-propelling capsule endoscope using a magnetic field (with video)
    • Morita E, Ohtsuka N, Shindo Y, Nouda S, Kuramoto T, et al. 2010. In vivo trial of a driving system for a self-propelling capsule endoscope using a magnetic field (with video). Gastrointest. Endosc. 72(4):836-40
    • (2010) Gastrointest. Endosc. , vol.72 , Issue.4 , pp. 836-840
    • Morita, E.1    Ohtsuka, N.2    Shindo, Y.3    Nouda, S.4    Kuramoto, T.5
  • 118
    • 34250583541 scopus 로고
    • Intraluminal biopsy of the small intestine
    • Crosby WH, Kugler HW. 1957. Intraluminal biopsy of the small intestine. Dig. Dis. Sci. 2(5): 236-41
    • (1957) Dig. Dis. Sci. , vol.2 , Issue.5 , pp. 236-241
    • Crosby, W.H.1    Kugler, H.W.2
  • 119
    • 79957988670 scopus 로고    scopus 로고
    • A rotationalmicro biopsy device for the capsule endoscope
    • Aug. 2-6, Edmonton, Can., Piscataway, NJ: IEEE
    • Kong K, Cha J, JeonD, Cho DD. 2005. A rotationalmicro biopsy device for the capsule endoscope. Proc. IEEE/RSJ Int. Conf. Intell. Robots Syst., Aug. 2-6, Edmonton, Can., pp. 1839-43. Piscataway, NJ: IEEE
    • (2005) Proc. IEEE/RSJ Int. Conf. Intell. Robots Syst. , pp. 1839-1843
    • Kong, K.1    Cha, J.2    Jeond Cho, D.D.3
  • 124
    • 0034325383 scopus 로고    scopus 로고
    • Development of a new engineering-based capsule for human drug absorption studies
    • Wilding I, Hirst P, Connor A. 2000. Development of a new engineering-based capsule for human drug absorption studies. Pharm. Sci. Technol. Today 3:385-92
    • (2000) Pharm. Sci. Technol. Today , vol.3 , pp. 385-392
    • Wilding, I.1    Hirst, P.2    Connor, A.3
  • 126
    • 84857030080 scopus 로고    scopus 로고
    • Design and rolling locomotion of a magnetically actuated soft capsule endoscope
    • Yim S, Sitti M. 2012. Design and rolling locomotion of a magnetically actuated soft capsule endoscope. IEEE Trans. Robot. 28(1):183-94
    • (2012) IEEE Trans. Robot. , vol.28 , Issue.1 , pp. 183-194
    • Yim, S.1    Sitti, M.2
  • 127
    • 77954312067 scopus 로고    scopus 로고
    • A novel micro-fabricated thruster for drug release in remote controlled capsule
    • Pi X, Lin Y, Wei K, Liu H, Wang G, et al. 2010. A novel micro-fabricated thruster for drug release in remote controlled capsule. Sens. Actuators A 159(2):227-32
    • (2010) Sens. Actuators A , vol.159 , Issue.2 , pp. 227-232
    • Pi, X.1    Lin, Y.2    Wei, K.3    Liu, H.4    Wang, G.5
  • 128
    • 80055074935 scopus 로고    scopus 로고
    • Mucoadhesive film for anchoring assistive surgical instruments in endoscopic surgery: In vivo assessment of deployment and attachment
    • Pensabene V, Valdastri P, Tognarelli S, Menciassi A, Arezzo A, Dario P. 2011. Mucoadhesive film for anchoring assistive surgical instruments in endoscopic surgery: in vivo assessment of deployment and attachment. Surg. Endosc. 25(9):3071-79
    • (2011) Surg. Endosc. , vol.25 , Issue.9 , pp. 3071-3079
    • Pensabene, V.1    Valdastri, P.2    Tognarelli, S.3    Menciassi, A.4    Arezzo, A.5    Dario, P.6
  • 131
    • 34447309715 scopus 로고    scopus 로고
    • Wireless power transfer via strongly coupled magnetic resonances
    • DOI 10.1126/science.1143254
    • Kurs A, Karalis A, Moffatt R, Joannopoulos JD, Fisher P, Soljačić M. 2007. Wireless power transfer via strongly coupled magnetic resonances. Science 317(5834):83-86 (Pubitemid 47056459)
    • (2007) Science , vol.317 , Issue.5834 , pp. 83-86
    • Kurs, A.1    Karalis, A.2    Moffatt, R.3    Joannopoulos, J.D.4    Fisher, P.5    Soljacic, M.6
  • 132
    • 70350422333 scopus 로고    scopus 로고
    • Wireless powering for a self-propelled and steerable endoscopic capsule for stomach inspection
    • Carta R, Tortora G, Thon?e J, Lenaerts B, Valdastri P, et al. 2009. Wireless powering for a self-propelled and steerable endoscopic capsule for stomach inspection. Biosens. Bioelectron. 25:845-51
    • (2009) Biosens. Bioelectron. , vol.25 , pp. 845-851
    • Carta, R.1    Tortora, G.2    Thone, J.3    Lenaerts, B.4    Valdastri, P.5
  • 133
    • 77954841219 scopus 로고    scopus 로고
    • A method for improving the wireless power transmission efficiency of an endoscopic capsule based on electromagnetic localization and synthesis of magnetic field vector
    • Li H, Yan G, Gao P. 2010. A method for improving the wireless power transmission efficiency of an endoscopic capsule based on electromagnetic localization and synthesis of magnetic field vector. Proc. Inst. Mech. Eng. C 224(7):1463-71
    • (2010) Proc. Inst. Mech. Eng. C , vol.224 , Issue.7 , pp. 1463-1471
    • Li, H.1    Yan, G.2    Gao, P.3
  • 135
    • 37249063857 scopus 로고    scopus 로고
    • Culture of insect cells contracting spontaneously; research moving toward an environmentally robust hybrid robotic system
    • DOI 10.1016/j.jbiotec.2007.08.042, PII S0168165607015301, System Cell Engineering by Multi-Scale Manipulation
    • Akiyama Y, Iwabuchi K, Furukawa Y, Morishima K. 2008. Culture of insect cells contracting spontaneously; research moving toward an environmentally robust hybrid robotic system. J. Biotechnol. 133(2):261-66 (Pubitemid 350266908)
    • (2008) Journal of Biotechnology , vol.133 , Issue.2 , pp. 261-266
    • Akiyama, Y.1    Iwabuchi, K.2    Furukawa, Y.3    Morishima, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.