-
2
-
-
0002063410
-
A flexible fiberscope, using static scanning
-
Hopkins HH, Kapany NS. 1954. A flexible fiberscope, using static scanning. Nature 173:39-41
-
(1954)
Nature
, vol.173
, pp. 39-41
-
-
Hopkins, H.H.1
Kapany, N.S.2
-
3
-
-
79952061753
-
The colorectal cancer control program: Partnering to increase population level screening
-
Joseph DA, DeGroff AS, HayesNS, Wong FL, Plescia M. 2011. The colorectal cancer control program: partnering to increase population level screening. Gastrointest. Endosc. 73(3):429-34
-
(2011)
Gastrointest. Endosc.
, vol.73
, Issue.3
, pp. 429-434
-
-
Joseph, D.A.1
Degroff, A.S.2
Hayesns Wong, F.L.3
Plescia, M.4
-
6
-
-
84875242319
-
-
Nat. Dig. Dis. Inf. Clgh., NIH Publ. No. 10-3873
-
Nat. Dig. Dis. Inf. Clgh. 2010. Digestive diseases statistics for the United States. NIH Publ. No. 10-3873. http://digestive.niddk.nih.gov/statistics/ statistics.aspx
-
(2010)
Digestive Diseases Statistics for the United States
-
-
-
7
-
-
0030005551
-
The risk of stomach cancer in patients with gastric or duodenal ulcer disease
-
DOI 10.1056/NEJM199607253350404
-
Hansson LE, Nyrén O, Hsing AW, Bergström R, Josefsson S, et al. 1996. The risk of stomach cancer in patients with gastric or duodenal ulcer disease. N. Engl. J. Med. 335(4):242-49 (Pubitemid 26249572)
-
(1996)
New England Journal of Medicine
, vol.335
, Issue.4
, pp. 242-249
-
-
Hansson, L.-E.1
Nyren, O.2
Hsing, A.W.3
Bergstrom, R.4
Josefsson, S.5
Chow, W.-H.6
Fraumeni Jr., J.F.7
Adami, H.-O.8
-
10
-
-
14544287404
-
Meckel diverticulum: The Mayo Clinic experience with 1476 patients (1950-2002)
-
DOI 10.1097/01.sla.0000154270.14308.5f
-
Park JJ, Wolff BG, Tollefson MK, Walsh EE, Larson DR. 2005. Meckel diverticulum: theMayo Clinic experience with 1476 patients (1950-2002). Ann. Surg. 241:529-33 (Pubitemid 40299732)
-
(2005)
Annals of Surgery
, vol.241
, Issue.3
, pp. 529-533
-
-
Park, J.J.1
Wolff, B.G.2
Tollefson, M.K.3
Walsh, E.E.4
Larson, D.R.5
-
11
-
-
0031650290
-
Preparation of patients for gastrointestinal endoscopy
-
Am. Soc. Gastrointest. Endos.
-
Am. Soc. Gastrointest. Endos. 1998. Preparation of patients for gastrointestinal endoscopy. Gastrointest. Endosc. 48:691-94
-
(1998)
Gastrointest. Endosc.
, vol.48
, pp. 691-694
-
-
-
13
-
-
67650169924
-
Barriers to colorectal cancer screening: A case-control study
-
Cai SR, Zhang SZ, Zhu HH, Zheng S. 2009. Barriers to colorectal cancer screening: a case-control study. World J. Gastroenterol. 15(20):2531-36
-
(2009)
World J. Gastroenterol.
, vol.15
, Issue.20
, pp. 2531-2536
-
-
Cai, S.R.1
Zhang, S.Z.2
Zhu, H.H.3
Zheng, S.4
-
14
-
-
79959768719
-
GI endoscopes
-
Varadarajulu S, Banerjee S, Barth BA, Desilets DJ, Kaul V, et al. 2011. GI endoscopes. Gastrointest. Endosc. 74:1-6
-
(2011)
Gastrointest. Endosc.
, vol.74
, pp. 1-6
-
-
Varadarajulu, S.1
Banerjee, S.2
Barth, B.A.3
Desilets, D.J.4
Kaul, V.5
-
15
-
-
77951519387
-
Ultrathin endoscopes
-
Rodriguez S, Banerjee S, Desilets D, Diehl DL, Farraye FA, et al. 2010. Ultrathin endoscopes. Gastrointest. Endosc. 71:893-98
-
(2010)
Gastrointest. Endosc.
, vol.71
, pp. 893-898
-
-
Rodriguez, S.1
Banerjee, S.2
Desilets, D.3
Diehl, D.L.4
Farraye, F.A.5
-
16
-
-
78049338868
-
Randomized comparison of 3 different-sized biopsy forceps for quality of sampling in Barrett's esophagus
-
Gonzalez S, Yu WM, Smith MS, Slack KN, Rotterdam H, et al. 2010. Randomized comparison of 3 different-sized biopsy forceps for quality of sampling in Barrett's esophagus. Gastrointest. Endosc. 72:935-40
-
(2010)
Gastrointest. Endosc.
, vol.72
, pp. 935-940
-
-
Gonzalez, S.1
Yu, W.M.2
Smith, M.S.3
Slack, K.N.4
Rotterdam, H.5
-
17
-
-
66849091425
-
Brush cytology for the diagnosis of colorectal cancer
-
Brouwer R, MacDonald A, Matthews R, Gunn J, Monson JR, Hartley JE. 2009. Brush cytology for the diagnosis of colorectal cancer. Dis. Colon Rectum 52:598-601
-
(2009)
Dis. Colon Rectum
, vol.52
, pp. 598-601
-
-
Brouwer, R.1
MacDonald, A.2
Matthews, R.3
Gunn, J.4
Monson, J.R.5
Hartley, J.E.6
-
18
-
-
0036517087
-
Procedural success and complications of large-scale screening colonoscopy
-
DOI 10.1067/mge.2002.121883
-
Nelson DB, McQuaid KR, Bond JH, Lieberman DA, Weiss DG, JohnstonTK. 2002. Procedural success and complications of large-scale screening colonoscopy. Gastrointest. Endosc. 55(3):307-14 (Pubitemid 41115140)
-
(2002)
Gastrointestinal Endoscopy
, vol.55
, Issue.3
, pp. 307-314
-
-
Nelson, D.B.1
McQuaid, K.R.2
Bond, J.H.3
Lieberman, D.A.4
Weiss, D.G.5
Johnston, T.K.6
Harford, W.V.7
Ahnen, D.J.8
Provenzale, D.9
Sontag, S.J.10
Schnell, T.G.11
Campbell, D.R.12
Durbin, T.E.13
Lee, J.G.14
Triadafilopoulos, G.15
Ramirez, F.C.16
Collins, J.F.17
Fennerty, M.B.18
Garewal, H.19
Sampliner, R.E.20
Morales, T.G.21
Fass, R.22
Smith, R.E.23
Maheshwari, Y.24
more..
-
19
-
-
0033842460
-
The measures of forces exerted during colonoscopy
-
Appleyard MN, Mosse CA, Mills TN, Bell GD, Castillo FD, Swain CP. 2000. The measures of forces exerted during colonoscopy. Gastrointest. Endosc. 52:237-40
-
(2000)
Gastrointest. Endosc.
, vol.52
, pp. 237-240
-
-
Appleyard, M.N.1
Mosse, C.A.2
Mills, T.N.3
Bell, G.D.4
Castillo, F.D.5
Swain, C.P.6
-
20
-
-
0035458872
-
Complications of diagnostic and therapeutic colonoscopy within a defined population in Sweden
-
DOI 10.1067/mge.2001.117545
-
Dafnis G, Ekbom A, Pahlman L, Blomqvist P. 2001. Complication of diagnostic and therapeutic colonoscopy within a defined population in Sweden. Gastrointest. Endosc. 54:302-9 (Pubitemid 33665508)
-
(2001)
Gastrointestinal Endoscopy
, vol.54
, Issue.3
, pp. 302-309
-
-
Dafnis, G.1
Ekbom, A.2
Pahlman, L.3
Blomqvist, P.4
-
21
-
-
79952492150
-
Scopes too flexible. . . and Too Stiff
-
Loeve A, Breedveld P, Dankelman J. 2010. Scopes too flexible. . . and too stiff. IEEE Pulse 1(3):26-41
-
(2010)
IEEE Pulse
, vol.1
, Issue.3
, pp. 26-41
-
-
Loeve, A.1
Breedveld, P.2
Dankelman, J.3
-
22
-
-
33846500663
-
Computer-assisted colonoscopy (the NeoGuide Endoscopy System): Results of the first human clinical trial ("PACE Study")
-
DOI 10.1111/j.1572-0241.2006.01002.x
-
Eickhoff A, van Dam J, Jakobs R, Kudis V, Hartmann D, et al. 2007. Computer-assisted colonoscopy (the NeoGuide Endoscopy System): results of the first human clinical trial ("PACE study"). Am. J. Gastroenterol. 102(2):261-66 (Pubitemid 46160537)
-
(2007)
American Journal of Gastroenterology
, vol.102
, Issue.2
, pp. 261-266
-
-
Eickhoff, A.1
Van Dam, J.2
Jakobs, R.3
Kudis, V.4
Hartmann, D.5
Damian, U.6
Weickert, U.7
Schilling, D.8
Riemann, J.F.9
-
23
-
-
41049105968
-
An adequate level of training for technical competence in screening and diagnostic colonoscopy: A prospectivemulticenter evaluation of the learning curve
-
Lee SH, Chung IK, Kim SJ, Kim JO, Ko BM, et al. 2008. An adequate level of training for technical competence in screening and diagnostic colonoscopy: a prospectivemulticenter evaluation of the learning curve. Gastrointest. Endosc. 67(4):683-89
-
(2008)
Gastrointest. Endosc.
, vol.67
, Issue.4
, pp. 683-689
-
-
Lee, S.H.1
Chung, I.K.2
Kim, S.J.3
Kim, J.O.4
Ko, B.M.5
-
24
-
-
60149097010
-
Update on CT colonography
-
Farraye FA, Adler DG, Chand B, Conway JD, Diehl DL, et al. 2009. Update on CT colonography. Gastrointest. Endosc. 69(3, Pt. 1):393-98
-
(2009)
Gastrointest. Endosc.
, vol.69
, Issue.3 PART 1
, pp. 393-398
-
-
Farraye, F.A.1
Adler, D.G.2
Chand, B.3
Conway, J.D.4
Diehl, D.L.5
-
25
-
-
32244449015
-
Virtual colonoscopy in the detection of colonic polyps and neoplasms
-
DOI 10.1016/j.bpg.2005.08.004, PII S1521691805001150, Advances in Imaging of the Gastrointestinal Trct
-
O'Hare A, Fenlon H. 2006. Virtual colonoscopy in the detection of colonic polyps and neoplasm. Best Pract. Res. Clin. Gastroenterol. 20:79-92 (Pubitemid 43210628)
-
(2006)
Best Practice and Research: Clinical Gastroenterology
, vol.20
, Issue.1
, pp. 79-92
-
-
O'Hare, A.1
Fenlon, H.2
-
26
-
-
0345690179
-
Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults
-
DOI 10.1056/NEJMoa031618
-
Pickhardt PJ, Choi JR, Hwang I, Butler JA, Puckett ML, et al. 2003. Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults. N. Engl. J.Med. 349(23):2191-200 (Pubitemid 37485135)
-
(2003)
New England Journal of Medicine
, vol.349
, Issue.23
, pp. 2191-2200
-
-
Pickhardt, P.J.1
Choi, J.R.2
Hwang, I.3
Butler, J.A.4
Puckett, M.L.5
Hildebrandt, H.A.6
Wong, R.K.7
Nugent, P.A.8
Mysliwiec, P.A.9
Schindler, W.R.10
-
27
-
-
78549239198
-
Computed tomographic colonography: Ready for prime time?
-
Rockey DC. 2010. Computed tomographic colonography: ready for prime time? Gastroenterol. Clin. N. Am. 39(4):901-9
-
(2010)
Gastroenterol. Clin. N. Am.
, vol.39
, Issue.4
, pp. 901-909
-
-
Rockey, D.C.1
-
28
-
-
0010723705
-
-
US Prev. Serv. Task Force.
-
US Prev. Serv. Task Force. 2008. Screening for colorectal cancer. http://www.uspreventiveservicestaskforce.org/uspstf/uspscolo.htm
-
(2008)
Screening for Colorectal Cancer
-
-
-
29
-
-
33751399423
-
The Cath-Cam: A new concept in colonoscopy
-
DOI 10.1016/j.gie.2006.06.033, PII S0016510706022735
-
Long G, Fritscher-Ravens A, Mosse CA, Mills T, Swain P. 2006. The Cath-Cam: a new concept in colonoscopy. Gastrointest. Endosc. 64(6):997-1001 (Pubitemid 44820078)
-
(2006)
Gastrointestinal Endoscopy
, vol.64
, Issue.6
, pp. 997-1001
-
-
Long, G.1
Fritscher-Ravens, A.2
Mosse, C.A.3
Mills, T.4
Swain, P.5
-
30
-
-
33344477634
-
The Aer-O-Scope: Proof of concept of a pneumatic, skill-independent, self-propelling, self-navigating colonoscope
-
DOI 10.1053/j.gastro.2005.12.018, PII S001650850502528X
-
Vucelic B, Rex D, Pulanic R, Pfefer J, Hrstic I, et al. 2006. The Aer-O-Scope: proof of concept of a pneumatic, skill-independent, self-propelling, self-navigating colonoscope. Gastroenterology 130(3):672-77 (Pubitemid 43374517)
-
(2006)
Gastroenterology
, vol.130
, Issue.3
, pp. 672-677
-
-
Vucelic, B.1
Rex, D.2
Pulanic, R.3
Pfefer, J.4
Hrstic, I.5
Levin, B.6
Halpern, Z.7
Arber, N.8
-
31
-
-
0036096056
-
Analysis and development of locomotion devices for the gastrointestinal tract
-
DOI 10.1109/TBME.2002.1001976
-
Phee L, Accoto D, Menciassi A, Stefanini C, Carrozza MC, Dario P. 2002. Analysis and development of locomotion devices for the gastrointestinal tract. IEEE Trans. Biomed. Eng. 49(6):613-16 (Pubitemid 34525965)
-
(2002)
IEEE Transactions on Biomedical Engineering
, vol.49
, Issue.6
, pp. 613-616
-
-
Phee, L.1
Accoto, D.2
Menciassi, A.3
Stefanini, C.4
Carrozza, M.C.5
Dario, P.6
-
32
-
-
78649702903
-
Endotics system vs. colonoscopy for the detection of polyps
-
Tumino E, Sacco R, Bertini M, Bertoni M, Parisi G, Capria A. 2010. Endotics system vs. colonoscopy for the detection of polyps. World J. Gastroenterol. 16(43):5452-56
-
(2010)
World J. Gastroenterol.
, vol.16
, Issue.43
, pp. 5452-5456
-
-
Tumino, E.1
Sacco, R.2
Bertini, M.3
Bertoni, M.4
Parisi, G.5
Capria, A.6
-
33
-
-
44349191500
-
A motor-driven single-use colonoscope controlled with a hand-held device: As feasibility study in volunteers
-
DOI 10.1016/j.gie.2007.10.065, PII S0016510707030532
-
Rösch T, Adler A, PohlH, Wettschureck E, KochM, et al. 2008. Amotor-driven single-use colonoscope controlled with a hand-held device: a feasibility study in volunteers. Gastrointest. Endosc. 67(7):1139-46 (Pubitemid 351728110)
-
(2008)
Gastrointestinal Endoscopy
, vol.67
, Issue.7
, pp. 1139-1146
-
-
Rosch, T.1
Adler, A.2
Pohl, H.3
Wettschureck, E.4
Koch, M.5
Wiedenmann, B.6
Hoepffner, N.7
-
34
-
-
79958012679
-
High cecal intubation rateswith a new computer-assisted colonoscope: A feasibility study
-
Groth S, Rex DK, Rösch T, Hoepffner N. 2011. High cecal intubation rateswith a new computer-assisted colonoscope: a feasibility study. Am. J. Gastroenterol. 106:1075-80
-
(2011)
Am. J. Gastroenterol.
, vol.106
, pp. 1075-1080
-
-
Groth, S.1
Rex, D.K.2
Rösch, T.3
Hoepffner, N.4
-
35
-
-
53149122276
-
Sightline ColonoSight system for a disposable, power-assisted, non-fiber-optic colonoscopy (with video)
-
Shike M, Fireman Z, Eliakim R, Segol O, Sloyer A, et al. 2008. Sightline ColonoSight system for a disposable, power-assisted, non-fiber-optic colonoscopy (with video). Gastrointest. Endosc. 68(4):701-10
-
(2008)
Gastrointest. Endosc.
, vol.68
, Issue.4
, pp. 701-710
-
-
Shike, M.1
Fireman, Z.2
Eliakim, R.3
Segol, O.4
Sloyer, A.5
-
36
-
-
84863530054
-
Magnetic air capsule robotic system: Proof of concept of a novel approach for painless colonoscopy
-
Valdastri P, Ciuti G, Verbeni A, Menciassi A, Dario P, et al. 2012. Magnetic air capsule robotic system: proof of concept of a novel approach for painless colonoscopy. Surg. Endosc. 26(5):1238-46
-
(2012)
Surg. Endosc.
, vol.26
, Issue.5
, pp. 1238-1246
-
-
Valdastri, P.1
Ciuti, G.2
Verbeni, A.3
Menciassi, A.4
Dario, P.5
-
37
-
-
79952051004
-
Spiral overtubeassisted colonoscopy after incomplete colonoscopy in the redundant colon
-
Schembre DB, Ross AS, Gluck MN, Brandabur JJ, McCormick SE, Lin OS. 2011. Spiral overtubeassisted colonoscopy after incomplete colonoscopy in the redundant colon. Gastrointest. Endosc. 73(3):515-19
-
(2011)
Gastrointest. Endosc.
, vol.73
, Issue.3
, pp. 515-519
-
-
Schembre, D.B.1
Ross, A.S.2
Gluck, M.N.3
Brandabur, J.J.4
McCormick, S.E.5
Lin, O.S.6
-
38
-
-
84857038067
-
Evaluation of magnetic scope navigation in screening endoscopic examination of colorectal cancer
-
Szura M, Bucki K, Matyja A, Kulig J. 2012. Evaluation of magnetic scope navigation in screening endoscopic examination of colorectal cancer. Surg. Endosc. 26:632-38
-
(2012)
Surg. Endosc.
, vol.26
, pp. 632-638
-
-
Szura, M.1
Bucki, K.2
Matyja, A.3
Kulig, J.4
-
39
-
-
77957299548
-
A novel device for rapid cleaning of poorly prepared colons
-
Moshkowitz M, Hirsch Y, Carmel I, Duvdevany T, Fabian I, et al. 2010. A novel device for rapid cleaning of poorly prepared colons. Endoscopy 42(10):834-36
-
(2010)
Endoscopy
, vol.42
, Issue.10
, pp. 834-836
-
-
Moshkowitz, M.1
Hirsch, Y.2
Carmel, I.3
Duvdevany, T.4
Fabian, I.5
-
40
-
-
29244452600
-
Colon cleaning during colonoscopy: A new mechanical cleaning device tested in a porcine model
-
DOI 10.1016/j.gie.2005.05.023, PII S001651070502105X
-
Fritscher-Ravens A, Mosse CA, Mills T, Ikeda K, Swain P. 2006. Colon cleaning during colonoscopy: a new mechanical cleaning device tested in a porcine model. Gastrointest. Endosc. 63:141-43 (Pubitemid 41827793)
-
(2006)
Gastrointestinal Endoscopy
, vol.63
, Issue.1
, pp. 141-143
-
-
Fritscher-Ravens, A.1
Mosse, C.A.2
Mills, T.3
Ikeda, K.4
Swain, P.5
-
42
-
-
0036895017
-
Colonoscopic miss rates determined by direct comparison of colonoscopy with colon resection specimens
-
Postic G, Lewin D, Bickerstaff C, Wallace MB. 2002. Colonoscopic miss rates determined by direct comparison of colonoscopy with colon resection specimens. Am. J. Gastroenterol. 97(12):3182-8543. Sauk J, Itzkowitz S.
-
(2002)
Am. J. Gastroenterol.
, vol.97
, Issue.12
, pp. 3182-8543
-
-
Postic, G.1
Lewin, D.2
Bickerstaff, C.3
Wallace, M.B.4
-
43
-
-
79952707882
-
Optical enhancements in diagnosis and surveillance of colorectal neoplasia
-
Sauk J, Itzkowitz S. 2011. Optical enhancements in diagnosis and surveillance of colorectal neoplasia. Curr. Colorectal Cancer Rep. 7:24-32
-
(2011)
Curr. Colorectal Cancer Rep.
, vol.7
, pp. 24-32
-
-
Sauk, J.1
Itzkowitz, S.2
-
44
-
-
84857918102
-
Comparison of the yield and miss rate of narrow band imaging and white light endoscopy in patients undergoing screening or surveillance colonoscopy: A meta-analysis
-
Pasha SF, Leighton JA, Das A, HarrisonME, Gurudu SR, et al. 2012. Comparison of the yield and miss rate of narrow band imaging and white light endoscopy in patients undergoing screening or surveillance colonoscopy: a meta-analysis. Am. J. Gastroenterol. 107:363-70
-
(2012)
Am. J. Gastroenterol.
, vol.107
, pp. 363-370
-
-
Pasha, S.F.1
Leighton, J.A.2
Das, A.3
Harrison, M.E.4
Gurudu, S.R.5
-
45
-
-
80053654631
-
High definition colonoscopy vs. standard video endoscopy for the detection of colonic polyps: A meta-analysis
-
Subramanian V, Mannath J, Hawkey CJ, Ragunath K. 2011. High definition colonoscopy vs. standard video endoscopy for the detection of colonic polyps: a meta-analysis. Endoscopy 43:499-505
-
(2011)
Endoscopy
, vol.43
, pp. 499-505
-
-
Subramanian, V.1
Mannath, J.2
Hawkey, C.J.3
Ragunath, K.4
-
46
-
-
80052041026
-
Spectroscopic detection of gastrointestinal dysplasia using optical microsensors
-
Ferreira DDS, Pinto VVC, Correia JJH, Minas GG. 2011. Spectroscopic detection of gastrointestinal dysplasia using optical microsensors. IEEE Trans. Biomed. Eng. 58(9):2633-39
-
(2011)
IEEE Trans. Biomed. Eng.
, vol.58
, Issue.9
, pp. 2633-2639
-
-
Ferreira, D.D.S.1
Pinto, V.V.C.2
Correia, J.J.H.3
Minas, G.G.4
-
47
-
-
77951644132
-
Advances in endoscopic imaging of colorectal neoplasia
-
Wallace MB, Kiesslich R. 2010. Advances in endoscopic imaging of colorectal neoplasia. Gastroenterology 138(6):2140-50
-
(2010)
Gastroenterology
, vol.138
, Issue.6
, pp. 2140-2150
-
-
Wallace, M.B.1
Kiesslich, R.2
-
48
-
-
0034713363
-
Wireless capsule endoscopy
-
Iddan G, Meron G, Glukhovsky A, Swain P. 2000. Wireless capsule endoscopy. Nature 405(6785):417
-
(2000)
Nature
, vol.405
, Issue.6785
, pp. 417
-
-
Iddan, G.1
Meron, G.2
Glukhovsky, A.3
Swain, P.4
-
49
-
-
77950594393
-
Comparison of a new PillCamTM SB2 video capsule versus the standard PillCamTM SB for detection of small bowel disease
-
Metzger YC, Adler SN, Bar-Gil Shitrit A, Koslowsky B, Bjarnason I. 2009. Comparison of a new PillCamTM SB2 video capsule versus the standard PillCamTM SB for detection of small bowel disease. Rep. Med. Imaging 2:7-11
-
(2009)
Rep. Med. Imaging
, vol.2
, pp. 7-11
-
-
Metzger, Y.C.1
Adler, S.N.2
Bar-Gil Shitrit, A.3
Koslowsky, B.4
Bjarnason, I.5
-
51
-
-
58649097129
-
First clinical trial of the "MiRo" capsule endoscope by using a novel transmission technology: Electric-field propagation
-
Bang S, Park J, Jeong S, Kim Y, ShimHB, et al. 2009. First clinical trial of the "MiRo" capsule endoscope by using a novel transmission technology: electric-field propagation. Gastrointest. Endosc. 69:253-59
-
(2009)
Gastrointest. Endosc.
, vol.69
, pp. 253-259
-
-
Bang, S.1
Park, J.2
Jeong, S.3
Shimhb, K.Y.4
-
52
-
-
77953482255
-
Fields of applications, diagnostic yields and findings of OMOM capsule endoscopy in 2400 Chinese patients
-
Liao Z, Gao R, Li F, Xu C, Zhou Y, et al. 2010. Fields of applications, diagnostic yields and findings of OMOM capsule endoscopy in 2400 Chinese patients. World J. Gastroenterol. 16(21):2669
-
(2010)
World J. Gastroenterol.
, vol.16
, Issue.21
, pp. 2669
-
-
Liao, Z.1
Gao, R.2
Li, F.3
Xu, C.4
Zhou, Y.5
-
53
-
-
47349117975
-
A prospective, single-blind trial comparing wireless capsule endoscopy and double-balloon enteroscopy in patients with obscure gastrointestinal bleeding
-
DOI 10.1007/s00535-008-2182-9
-
Kameda N, Higuchi K, Shiba M, Machida H, Okazaki H, et al. 2008. A prospective, single-blind trial comparing wireless capsule endoscopy and double-balloon enteroscopy in patients with obscure gastrointestinal bleeding. J. Gastroenterol. 43(6):434-40 (Pubitemid 351997880)
-
(2008)
Journal of Gastroenterology
, vol.43
, Issue.6
, pp. 434-440
-
-
Kameda, N.1
Higuchi, K.2
Shiba, M.3
Machida, H.4
Okazaki, H.5
Yamagami, H.6
Tanigawa, T.7
Watanabe, K.8
Watanabe, T.9
Tominaga, K.10
Fujiwara, Y.11
Oshitani, N.12
Arakawa, T.13
-
54
-
-
50949104729
-
Safety, reliability and limitations of the given patency capsule in patients at risk of capsule retention: A 3-year technical review
-
Postgate AJ, Burling D, Gupta A, Fitzpatrick A, Fraser C. 2008. Safety, reliability and limitations of the given patency capsule in patients at risk of capsule retention: a 3-year technical review. Dig. Dis. Sci. 53(10):2732-38
-
(2008)
Dig. Dis. Sci.
, vol.53
, Issue.10
, pp. 2732-2738
-
-
Postgate, A.J.1
Burling, D.2
Gupta, A.3
Fitzpatrick, A.4
Fraser, C.5
-
55
-
-
76349101674
-
Diagnostic accuracy of esophageal capsule endoscopy versus conventional upper digestive endoscopy for suspected esophageal squamous cell carcinoma
-
Heresbach D, Leray E, d'Halluin PN, Cholet F, Lapalus MG, et al. 2010. Diagnostic accuracy of esophageal capsule endoscopy versus conventional upper digestive endoscopy for suspected esophageal squamous cell carcinoma. Endoscopy 42(2):93-97
-
(2010)
Endoscopy
, vol.42
, Issue.2
, pp. 93-97
-
-
Heresbach, D.1
Leray, E.2
D'halluin, P.N.3
Cholet, F.4
Lapalus, M.G.5
-
56
-
-
77749328946
-
European Society of Gastrointestinal Endoscopy (ESGE): Recommendations (2009) on clinical use of video capsule endoscopy to investigate small-bowel, esophageal and colonic diseases
-
Ladas SD, Triantafyllou K, Spada C, Riccioni ME, Rey JF, et al. 2010. European Society of Gastrointestinal Endoscopy (ESGE): recommendations (2009) on clinical use of video capsule endoscopy to investigate small-bowel, esophageal and colonic diseases. Endoscopy 42(3):220-27
-
(2010)
Endoscopy
, vol.42
, Issue.3
, pp. 220-227
-
-
Ladas, S.D.1
Triantafyllou, K.2
Spada, C.3
Riccioni, M.E.4
Rey, J.F.5
-
57
-
-
80052244323
-
Second-generation colon capsule endoscopy compared with colonoscopy
-
Spada C, Hassan C, Munoz-Navas M, Neuhaus H, Deviere J, et al. 2011. Second-generation colon capsule endoscopy compared with colonoscopy. Gastrointest. Endosc. 74(3):581-89.e1
-
(2011)
Gastrointest. Endosc.
, vol.74
, Issue.3
-
-
Spada, C.1
Hassan, C.2
Munoz-Navas, M.3
Neuhaus, H.4
Deviere, J.5
-
58
-
-
77957116048
-
Miniaturized digital camera system for disposable endoscopic applications
-
Covi D, Cavallotti C, Vatteroni M, Clementel L, Valdastri P, et al. 2010. Miniaturized digital camera system for disposable endoscopic applications. Sens. Actuators A 162(2):291-96
-
(2010)
Sens. Actuators A
, vol.162
, Issue.2
, pp. 291-296
-
-
Covi, D.1
Cavallotti, C.2
Vatteroni, M.3
Clementel, L.4
Valdastri, P.5
-
59
-
-
71649104121
-
Design of a 2 Mbps FSK near-field transmitter for wireless capsule endoscopy
-
Thoné J, Radiom S, Turgis D, Carta R, Gielen G, Puers R. 2009. Design of a 2 Mbps FSK near-field transmitter for wireless capsule endoscopy. Sens. Actuators A 156(1):43-48
-
(2009)
Sens. Actuators A
, vol.156
, Issue.1
, pp. 43-48
-
-
Thoné, J.1
Radiom, S.2
Turgis, D.3
Carta, R.4
Gielen, G.5
Puers, R.6
-
60
-
-
33644936402
-
An ultra-low-power image compressor for capsule endoscope
-
Lin MC, Dung LR, Weng PK. 2006. An ultra-low-power image compressor for capsule endoscope. Biomed. Eng. Online 5:14
-
(2006)
Biomed. Eng. Online
, vol.5
, pp. 14
-
-
Lin, M.C.1
Dung, L.R.2
Weng, P.K.3
-
61
-
-
78649950985
-
A novel JPEG-based wireless capsule endoscope
-
Pan G, Yan G, Qiu X, Song X. 2010. A novel JPEG-based wireless capsule endoscope. Biomed. Instrum. Technol. 44(6):519-22
-
(2010)
Biomed. Instrum. Technol.
, vol.44
, Issue.6
, pp. 519-522
-
-
Pan, G.1
Yan, G.2
Qiu, X.3
Song, X.4
-
62
-
-
47849116075
-
Hardware implementation aspects of new low complexity image coding algorithm for wireless capsule endoscopy
-
Turcza P, Zieliński T, Duplaga M. 2008. Hardware implementation aspects of new low complexity image coding algorithm for wireless capsule endoscopy. Lect. Notes Comput. Sci. 5101:476-85
-
(2008)
Lect. Notes Comput. Sci.
, vol.5101
, pp. 476-485
-
-
Turcza, P.1
Zieliński, T.2
Duplaga, M.3
-
63
-
-
79956355269
-
A wideband spiral antenna for ingestible capsule endoscope systems: Experimental results in a human phantom and a pig
-
Lee S, Lee J, Yoon Y, Park S, Cheon C, et al. 2011. A wideband spiral antenna for ingestible capsule endoscope systems: experimental results in a human phantom and a pig. IEEE Trans. Biomed. Eng. 58:1734-41
-
(2011)
IEEE Trans. Biomed. Eng.
, vol.58
, pp. 1734-1741
-
-
Lee, S.1
Lee, J.2
Yoon, Y.3
Park, S.4
Cheon, C.5
-
64
-
-
77957148039
-
Smart optical CMOS sensor for endoluminal applications
-
Vatteroni M, Covi D, Cavallotti C, Clementel L, Valdastri P, et al. 2010. Smart optical CMOS sensor for endoluminal applications. Sens. Actuators A 162(2):297-303
-
(2010)
Sens. Actuators A
, vol.162
, Issue.2
, pp. 297-303
-
-
Vatteroni, M.1
Covi, D.2
Cavallotti, C.3
Clementel, L.4
Valdastri, P.5
-
65
-
-
79953098280
-
Linear-logarithmic CMOS pixel with tunable dynamic range
-
Vatteroni M, Valdastri P, Sartori A, Menciassi A, Dario P. 2011. Linear-logarithmic CMOS pixel with tunable dynamic range. IEEE Trans. Electron Devices 58(4):1108-15
-
(2011)
IEEE Trans. Electron Devices
, vol.58
, Issue.4
, pp. 1108-1115
-
-
Vatteroni, M.1
Valdastri, P.2
Sartori, A.3
Menciassi, A.4
Dario, P.5
-
66
-
-
82755189714
-
An FPGA-based versatile development system for endoscopic capsule design optimization
-
Cavallotti C, Merlino P, Vatteroni M, Valdastri P, Abramo A, et al. 2011. An FPGA-based versatile development system for endoscopic capsule design optimization. Sens. Actuators A 172(1):301-7
-
(2011)
Sens. Actuators A
, vol.172
, Issue.1
, pp. 301-307
-
-
Cavallotti, C.1
Merlino, P.2
Vatteroni, M.3
Valdastri, P.4
Abramo, A.5
-
67
-
-
78649515205
-
A wireless narrowband imaging chip for capsule endoscope
-
Dung LR, Wu YY. 2010. A wireless narrowband imaging chip for capsule endoscope. IEEE Trans. Biomed. Circuits Syst. 4(6):462-68
-
(2010)
IEEE Trans. Biomed. Circuits Syst.
, vol.4
, Issue.6
, pp. 462-468
-
-
Dung, L.R.1
Wu, Y.Y.2
-
68
-
-
85008018894
-
A multishutter time sensor for multispectral imaging in a 3-D reconstruction integrated sensor
-
Kolar A, Pinna A, Romain O, Viateur S, Ea T, et al. 2009. A multishutter time sensor for multispectral imaging in a 3-D reconstruction integrated sensor. IEEE Sens. J. 9(4):478-84
-
(2009)
IEEE Sens. J.
, vol.9
, Issue.4
, pp. 478-484
-
-
Kolar, A.1
Pinna, A.2
Romain, O.3
Viateur, S.4
Ea, T.5
-
69
-
-
71649106363
-
An integrated vision system with autofocus for wireless capsular endoscopy
-
Cavallotti C, Piccigallo M, Susilo E, Valdastri P, Menciassi A, Dario P. 2009. An integrated vision system with autofocus for wireless capsular endoscopy. Sens. Actuators A 156:72-78
-
(2009)
Sens. Actuators A
, vol.156
, pp. 72-78
-
-
Cavallotti, C.1
Piccigallo, M.2
Susilo, E.3
Valdastri, P.4
Menciassi, A.5
Dario, P.6
-
70
-
-
77952994843
-
A magnetic internal mechanism for precise orientation of the camera in wireless endoluminal applications
-
Valdastri P, Quaglia C, Buselli E, Arezzo A, Di Lorenzo N, et al. 2010. A magnetic internal mechanism for precise orientation of the camera in wireless endoluminal applications. Endoscopy 42(6):481-86
-
(2010)
Endoscopy
, vol.42
, Issue.6
, pp. 481-486
-
-
Valdastri, P.1
Quaglia, C.2
Buselli, E.3
Arezzo, A.4
Di Lorenzo, N.5
-
71
-
-
84864190613
-
A strategy to abstract WCE video clips based on LDA
-
May 9-13, Shanghai. Piscataway, NJ: IEEE
-
Zhao Q, Meng MQH. 2011. A strategy to abstract WCE video clips based on LDA. Proc. IEEE Conf. Robot. Autom. (ICRA '11), May 9-13, Shanghai, pp. 4145-50. Piscataway, NJ: IEEE
-
(2011)
Proc. IEEE Conf. Robot. Autom. (ICRA '11)
, pp. 4145-4150
-
-
Zhao, Q.1
Meng, M.Q.H.2
-
72
-
-
70350371279
-
Analysis of Crohn's disease lesions in capsule endoscopy images
-
May 12-17, Kobe, Jpn., Piscataway, NJ: IEEE
-
Bejakovic S, Kumar R, Dassopoulos T, Mullin G, Hager G. 2009. Analysis of Crohn's disease lesions in capsule endoscopy images. Proc. IEEE Conf. Robot. Autom. (ICRA '09), May 12-17, Kobe, Jpn., pp. 2793-98. Piscataway, NJ: IEEE
-
(2009)
Proc. IEEE Conf. Robot. Autom. (ICRA '09)
, pp. 2793-2798
-
-
Bejakovic, S.1
Kumar, R.2
Dassopoulos, T.3
Mullin, G.4
Hager, G.5
-
73
-
-
62549152628
-
A model of deformable rings for interpretation of wireless capsule endoscopic videos
-
Szczypinski PM, Sriram RD, Sriram PVJ, Reddy DN. 2009. A model of deformable rings for interpretation of wireless capsule endoscopic videos. Med. Image Anal. 13(2):312-24
-
(2009)
Med. Image Anal.
, vol.13
, Issue.2
, pp. 312-324
-
-
Szczypinski, P.M.1
Sriram, R.D.2
Pvj, S.3
Reddy, D.N.4
-
74
-
-
78650823724
-
3D reconstruction of wireless capsule endoscopy images
-
Aug. 31-Sept. 4, Buenos Aires, Piscataway, NJ: IEEE
-
Fan Y, Meng MQH, Li B. 2010. 3D reconstruction of wireless capsule endoscopy images. Proc. 32nd Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., Aug. 31-Sept. 4, Buenos Aires, pp. 5149-52. Piscataway, NJ: IEEE
-
(2010)
Proc. 32nd Annu. Int. Conf. IEEE Eng. Med. Biol. Soc.
, pp. 5149-5152
-
-
Fan, Y.1
Meng, M.Q.H.2
Li, B.3
-
75
-
-
69549110664
-
Lumen detection for capsule endoscopy
-
Piscataway, NJ: IEEE
-
Zabulis X, Argyros AA, Tsakiris DP. 2008. Lumen detection for capsule endoscopy. Proc. IEEE/RSJ Int. Conf. Intell. Robots Syst., Sept. 22-26, Nice, Fr., pp. 3921-26. Piscataway, NJ: IEEE
-
(2008)
Proc. IEEE/RSJ Int. Conf. Intell. Robots Syst., Sept. 22-26, Nice, Fr.
, pp. 3921-3926
-
-
Zabulis, X.1
Argyros, A.A.2
Tsakiris, D.P.3
-
77
-
-
0013780795
-
Heidelberg capsule: I. in vitro evaluation of a new instrument for measuring intragastric pH
-
SteinbergWH, Mina FA, Pick PG, Frey GH. 1965. Heidelberg capsule: I. In vitro evaluation of a new instrument for measuring intragastric pH. J. Pharm. Sci. 54(5):772-76
-
(1965)
J. Pharm. Sci.
, vol.54
, Issue.5
, pp. 772-776
-
-
Steinberg, W.H.1
Mina, F.A.2
Pick, P.G.3
Frey, G.H.4
-
78
-
-
36348935715
-
Ingestible capsule for impedance and pH monitoring in the esophagus
-
DOI 10.1109/TBME.2007.908332
-
Gonzalez-Guillaumin J, Sadowski D, Kaler K, MintchevM. 2007. Ingestible capsule for impedance and pH monitoring in the esophagus. IEEE Trans. Biomed. Eng. 54:2231-36 (Pubitemid 350157799)
-
(2007)
IEEE Transactions on Biomedical Engineering
, vol.54
, Issue.12
, pp. 2231-2236
-
-
Gonzalez-Guillaumin, J.L.1
Sadowski, D.C.2
Kaler, K.V.I.S.3
Mintchev, M.P.4
-
79
-
-
4644277489
-
An implantable telemetry platform system for in vivo monitoring of physiological parameters
-
Valdastri P, Menciassi A, Arena A, CaccamoC, Dario P. 2004. An implantable telemetry platform system for in vivo monitoring of physiological parameters. IEEE Trans. Inf. Technol. Biomed. 8(3):271-78
-
(2004)
IEEE Trans. Inf. Technol. Biomed.
, vol.8
, Issue.3
, pp. 271-278
-
-
Valdastri, P.1
Menciassi, A.2
Arena, A.3
Caccamo, C.4
Dario, P.5
-
80
-
-
79953005262
-
An intelligent electronic capsule system for automated detection of gastrointestinal bleeding
-
Liu H, Wang G, Wei K, Pi XT, Zhu L, et al. 2010. An intelligent electronic capsule system for automated detection of gastrointestinal bleeding. J. Zhejiang Univ. Sci. B 11(12):937-43
-
(2010)
J. Zhejiang Univ. Sci. B
, vol.11
, Issue.12
, pp. 937-943
-
-
Liu, H.1
Wang, G.2
Wei, K.3
Pi, X.T.4
Zhu, L.5
-
81
-
-
10744225690
-
Implementation of Multichannel Sensors for Remote Biomedical Measurements in a Microsystems Format
-
DOI 10.1109/TBME.2003.820370
-
Johannessen EA, Wang L, Cui L, Tang TB, Ahmadian M, et al. 2004. Implementation of multichannel sensors for remote biomedical measurements in a microsystems format. IEEE Trans. Biomed. Eng. 51(3):525-35 (Pubitemid 38233792)
-
(2004)
IEEE Transactions on Biomedical Engineering
, vol.51
, Issue.3
, pp. 525-535
-
-
Johannessen, E.A.1
Wang, L.2
Cui, L.3
Tang, T.B.4
Ahmadian, M.5
Astaras, A.6
Reid, S.W.J.7
Yam, P.S.8
Murray, A.F.9
Flynn, B.W.10
Beaumont, S.P.11
Cumming, D.R.S.12
Cooper, J.M.13
-
82
-
-
80052074152
-
Characterization of the electrochemical behavior of gastrointestinal fluids using a multielectrode sensor probe
-
Twomey K, Alvarez de Eulate E, Marchesi JR, Kolida S, Gibson G, et al. 2011. Characterization of the electrochemical behavior of gastrointestinal fluids using a multielectrode sensor probe. IEEE Trans. Biomed. Eng. 58(9):2521-27
-
(2011)
IEEE Trans. Biomed. Eng.
, vol.58
, Issue.9
, pp. 2521-2527
-
-
Twomey, K.1
Alvarez De Eulate, E.2
Marchesi, J.R.3
Kolida, S.4
Gibson, G.5
-
83
-
-
1242296970
-
Capsule endoscopy: The localization system
-
DOI 10.1016/j.giec.2003.10.020
-
FischerD, Schreiber R, Levi D, Eliakim R. 2004. Capsule endoscopy: the localization system. Gastrointest. Endosc. Clin. N. Am. 14(1):25-31 (Pubitemid 38234301)
-
(2004)
Gastrointestinal Endoscopy Clinics of North America
, vol.14
, Issue.1
, pp. 25-31
-
-
Fischer, D.1
Schreiber, R.2
Levi, D.3
Eliakim, R.4
-
84
-
-
34047106904
-
A localization method using 3-axis magnetoresistive sensors for tracking of capsule endoscope
-
DOI 10.1109/IEMBS.2006.260711, 4029877, 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06
-
Wang X, Meng MQH, Hu C. 2006. A localization method using 3-axis magnetoresistive sensors for tracking of capsule endoscope. Proc. 28th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., Aug. 30-Sept. 3, New York, N.Y., pp. 2522-25. Piscataway, NJ: IEEE (Pubitemid 46520420)
-
(2006)
Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
, pp. 2522-2525
-
-
Wang, X.1
Meng, M.Q.-H.2
Hu, C.3
-
85
-
-
67149126558
-
Every slow-wave impulse is associated with motor activity of the human stomach
-
Hocke M, Schöne U, Richert H, Görnert P, Keller J, et al. 2008. Every slow-wave impulse is associated with motor activity of the human stomach. Am. J. Physiol. Gastrointest. Liver Physiol. 296:G709-16
-
(2008)
Am. J. Physiol. Gastrointest. Liver Physiol.
, vol.296
-
-
Hocke, M.1
Schöne, U.2
Richert, H.3
Görnert, P.4
Keller, J.5
-
86
-
-
38149025437
-
Wearable magnetic locating and tracking system for MEMS medical capsule
-
Wu X, HouW, Peng C, Zheng X, Fang X, He J. 2008. Wearable magnetic locating and tracking system for MEMS medical capsule. Sens. Actuators A 141(2):432-39
-
(2008)
Sens. Actuators A
, vol.141
, Issue.2
, pp. 432-439
-
-
Wu, X.1
Houw Peng, C.2
Zheng, X.3
Fang, X.4
He, J.5
-
87
-
-
33751059312
-
Capsule tracking in the GI tract: A novel microcontroller based solution
-
1634269, Proceedings of the 2006 IEEE Sensors Applications Symposium
-
Arshak K, Adepoju F. 2006. Capsule tracking in the GI tract: a novel microcontroller based solution. Proc. 2006 IEEE Sens. Appl. Symp., Feb. 7-9, Houston, Tex., pp. 186-91. Piscataway, NJ: IEEE (Pubitemid 44754605)
-
(2006)
Proceedings of the 2006 IEEE Sensors Applications Symposium
, pp. 186-191
-
-
Arshak, K.1
Adepoju, F.2
-
88
-
-
77949422045
-
Robotic magnetic steering and locomotion of capsule endoscope for diagnostic and surgical endoluminal procedures
-
Ciuti G, Valdastri P, Menciassi A, Dario P. 2010. Robotic magnetic steering and locomotion of capsule endoscope for diagnostic and surgical endoluminal procedures. Robotica 28(2):199-207
-
(2010)
Robotica
, vol.28
, Issue.2
, pp. 199-207
-
-
Ciuti, G.1
Valdastri, P.2
Menciassi, A.3
Dario, P.4
-
89
-
-
57649148582
-
Data processing tasks in wireless GI endoscopy: Image-based capsule localization & navigation and video compression
-
Piscataway, NJ: IEEE
-
Bulat J, Duda K, Duplaga M, Fraczek R, Skalski A, et al. 2007. Data processing tasks in wireless GI endoscopy: image-based capsule localization & navigation and video compression. Proc. 29th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., Aug. 23-26, Lyon, Fr., pp. 2815-18. Piscataway, NJ: IEEE
-
(2007)
Proc. 29th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., Aug. 23-26, Lyon, Fr.
, pp. 2815-2818
-
-
Bulat, J.1
Duda, K.2
Duplaga, M.3
Fraczek, R.4
Skalski, A.5
-
90
-
-
35348881151
-
Automatic classification of digestive organs in wireless capsule endoscopy videos
-
DOI 10.1145/1244002.1244230, Proceedings of the 2007 ACM Symposium on Applied Computing
-
Lee J, Oh J, Shah SK, Yuan X, Tang SJ. 2007. Automatic classification of digestive organs in wireless endoscopy videos. Proc. ACMSymp. Appl. Comput., Mar. 11-15, Seoul, pp. 1041-45. New York: Assoc. Comput. Mach. (Pubitemid 47569941)
-
(2007)
Proceedings of the ACM Symposium on Applied Computing
, pp. 1041-1045
-
-
Lee, J.1
Oh, J.2
Shah, S.K.3
Yuan, X.4
Tang, S.J.5
-
91
-
-
84867334830
-
A wireless module for vibratory motor control and inertial sensing in capsule endoscopy
-
In press, doi: 10.1016/j.sna.2011.12.024
-
Ciuti G, Pateromichelakis N, Sfakiotakis M, Valdastri P, Menciassi A, et al. 2012. A wireless module for vibratory motor control and inertial sensing in capsule endoscopy. Sens. Actuators A In press, doi: 10.1016/j.sna.2011.12.024
-
(2012)
Sens. Actuators A
-
-
Ciuti, G.1
Pateromichelakis, N.2
Sfakiotakis, M.3
Valdastri, P.4
Menciassi, A.5
-
92
-
-
34250782760
-
Evaluation of the critical stroke of an earthworm-like robot for capsule endoscopes
-
DOI 10.1243/09544119JEIM134
-
Kwon J, Park S, Park J, Kim B. 2007. Evaluation of the critical stroke of an earthworm-like robot for capsule endoscopes. Proc. Inst. Mech. Eng. H 221:397-405 (Pubitemid 46958916)
-
(2007)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.221
, Issue.4
, pp. 397-405
-
-
Kwon, J.1
Park, S.2
Park, J.3
Kim, B.4
-
93
-
-
49249105857
-
Structure optimization of the endoscopic robot ciliary leg based on dimensional analysis
-
Dec. 15-18, Sanya, China. Piscataway, NJ: IEEE
-
Feng Y, Li W, Li M, Sun L. 2007. Structure optimization of the endoscopic robot ciliary leg based on dimensional analysis. Proc. IEEE Int. Conf. Robot. Biomim., Dec. 15-18, Sanya, China, pp. 109-14. Piscataway, NJ: IEEE
-
(2007)
Proc. IEEE Int. Conf. Robot. Biomim.
, pp. 109-114
-
-
Feng, Y.1
Li, W.2
Li, M.3
Sun, L.4
-
94
-
-
33845567530
-
A novel SMA-based actuator for a legged endoscopic capsule
-
DOI 10.1109/BIOROB.2006.1639128, 1639128, Proceedings of the First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006, BioRob 2006
-
Gorini S, QuiriniM, Menciassi A, Pernorio G, Stefanini C, Dario P. 2006. A novel SMA-based actuator for a legged endoscopic capsule. Proc. IEEE/RAS-EMBS Int. Conf. Biomed. Robot. Biomechatron., Feb. 20-22, Pisa, Italy, pp. 443-49. Piscataway, NJ: IEEE (Pubitemid 44931165)
-
(2006)
Proceedings of the First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006, BioRob 2006
, vol.2006
, pp. 443-449
-
-
Gorini, S.1
Quirini, M.2
Menciassi, A.3
Pernorio, G.4
Stefanini, C.5
Dario, P.6
-
95
-
-
34250678873
-
An inchworm-like locomotion mechanism based on magnetic actuator for active capsule endoscope
-
DOI 10.1109/IROS.2006.281887, 4058543, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems, IROS 2006
-
Wang X, Meng MQH. 2006. An inchworm-like locomotion mechanism based on magnetic actuator for active capsule endoscope. Proc. IEEE/RSJ Int. Conf. Intell. Robots Syst., Oct. 9-15, Beijing, pp. 1267-72. Piscataway, NJ: IEEE (Pubitemid 46928070)
-
(2006)
IEEE International Conference on Intelligent Robots and Systems
, pp. 1267-1272
-
-
Wang, X.1
Meng, M.Q.-H.2
-
96
-
-
84862704610
-
Capsular microrobot using directional friction spiral
-
May 12-17, Kobe, Jpn., Piscataway, NJ: IEEE
-
Yim S, Jeona D. 2009. Capsular microrobot using directional friction spiral. Proc. IEEE Conf. Robot. Autom. (ICRA '09), May 12-17, Kobe, Jpn., pp. 4444-49. Piscataway, NJ: IEEE
-
(2009)
Proc. IEEE Conf. Robot. Autom. (ICRA '09)
, pp. 4444-4449
-
-
Yim, S.1
Jeona, D.2
-
97
-
-
77955699733
-
Active locomotion of a paddling-based capsule endoscope in an in vitro and in vivo experiment (with videos)
-
Kim HM, Yang S, Kim J, Park S, Cho JH, et al. 2010. Active locomotion of a paddling-based capsule endoscope in an in vitro and in vivo experiment (with videos). Gastrointest. Endosc. 72(2):381-87
-
(2010)
Gastrointest. Endosc.
, vol.72
, Issue.2
, pp. 381-387
-
-
Kim, H.M.1
Yang, S.2
Kim, J.3
Park, S.4
Cho, J.H.5
-
98
-
-
70350231536
-
A new mechanism for mesoscale legged locomotion in compliant tubular environments
-
Valdastri P, Webster RJ, Quaglia C, Quirini M, Menciassi A, Dario P. 2009. A new mechanism for mesoscale legged locomotion in compliant tubular environments. IEEE Trans. Robot. 25(5):1047-57
-
(2009)
IEEE Trans. Robot.
, vol.25
, Issue.5
, pp. 1047-1057
-
-
Valdastri, P.1
Webster, R.J.2
Quaglia, C.3
Quirini, M.4
Menciassi, A.5
Dario, P.6
-
99
-
-
65249120778
-
Superelastic leg design optimization for an endoscopic capsule with active locomotion
-
Buselli E, Valdastri P, Quirini M, Menciassi A, Dario P. 2009. Superelastic leg design optimization for an endoscopic capsule with active locomotion. Smart Mater. Struct. 18:1-7
-
(2009)
Smart Mater. Struct.
, vol.18
, pp. 1-7
-
-
Buselli, E.1
Valdastri, P.2
Quirini, M.3
Menciassi, A.4
Dario, P.5
-
100
-
-
78149388445
-
Evaluation of friction enhancement through soft polymer micro-patterns in active capsule endoscopy
-
Buselli E, Pensabene V, Castrataro P, Valdastri P, Menciassi A, Dario P. 2010. Evaluation of friction enhancement through soft polymer micro-patterns in active capsule endoscopy. Meas. Sci. Technol. 21:105802
-
(2010)
Meas. Sci. Technol.
, vol.21
, pp. 105802
-
-
Buselli, E.1
Pensabene, V.2
Castrataro, P.3
Valdastri, P.4
Menciassi, A.5
Dario, P.6
-
101
-
-
58149271167
-
A legged anchoring mechanism for capsule endoscopes using micropatterned adhesives
-
Glass P, Cheung E, Sitti M. 2008. A legged anchoring mechanism for capsule endoscopes using micropatterned adhesives. IEEE Trans. Biomed. Eng. 55(12):2759-67
-
(2008)
IEEE Trans. Biomed. Eng.
, vol.55
, Issue.12
, pp. 2759-2767
-
-
Glass, P.1
Cheung, E.2
Sitti, M.3
-
102
-
-
84857786411
-
MRI driven magnetic microswimmers
-
Kosa G, Jakab P, Szekely G, Hata N. 2012. MRI driven magnetic microswimmers. Biomed. Microdevices 14(1):165-78
-
(2012)
Biomed. Microdevices
, vol.14
, Issue.1
, pp. 165-178
-
-
Kosa, G.1
Jakab, P.2
Szekely, G.3
Hata, N.4
-
103
-
-
80051684454
-
A novel magnetic actuation system for miniature swimming robots
-
Valdastri P, Sinibaldi E, Caccavaro S, Tortora G, Menciassi A, Dario P. 2011. A novel magnetic actuation system for miniature swimming robots. IEEE Trans. Robot. 27(4):769-79
-
(2011)
IEEE Trans. Robot.
, vol.27
, Issue.4
, pp. 769-779
-
-
Valdastri, P.1
Sinibaldi, E.2
Caccavaro, S.3
Tortora, G.4
Menciassi, A.5
Dario, P.6
-
104
-
-
71649092073
-
A miniaturized wireless control platform for robotic capsular endoscopy using advanced pseudokernel approach
-
Susilo E, Valdastri P, Menciassi A, Dario P. 2009. A miniaturized wireless control platform for robotic capsular endoscopy using advanced pseudokernel approach. Sens. Actuators A 156(1):49-58
-
(2009)
Sens. Actuators A
, vol.156
, Issue.1
, pp. 49-58
-
-
Susilo, E.1
Valdastri, P.2
Menciassi, A.3
Dario, P.4
-
105
-
-
70350367416
-
Propeller-based wireless device for active capsular endoscopy in the gastric district
-
Tortora G, Valdastri P, Susilo E, Menciassi A, Dario P, et al. 2009. Propeller-based wireless device for active capsular endoscopy in the gastric district. Minim. Invasive Ther. Allied Technol. 18: 280-90
-
(2009)
Minim. Invasive Ther. Allied Technol.
, vol.18
, pp. 280-290
-
-
Tortora, G.1
Valdastri, P.2
Susilo, E.3
Menciassi, A.4
Dario, P.5
-
106
-
-
58149097640
-
Wireless therapeutic endoscopic capsule: In vivo experiment
-
Valdastri P, Quaglia C, Susilo E, Menciassi A, Dario P, et al. 2008. Wireless therapeutic endoscopic capsule: in vivo experiment. Endoscopy 40:979-82
-
(2008)
Endoscopy
, vol.40
, pp. 979-982
-
-
Valdastri, P.1
Quaglia, C.2
Susilo, E.3
Menciassi, A.4
Dario, P.5
-
107
-
-
77950593244
-
Design, fabrication, and testing of a capsule with hybrid locomotion for gastrointestinal tract exploration
-
Simi M, Valdastri P, Quaglia C, Menciassi A, Dario P. 2010. Design, fabrication, and testing of a capsule with hybrid locomotion for gastrointestinal tract exploration. IEEE/ASME Trans. Mechatron. 15(2):170-80
-
(2010)
IEEE/ASME Trans. Mechatron.
, vol.15
, Issue.2
, pp. 170-180
-
-
Simi, M.1
Valdastri, P.2
Quaglia, C.3
Menciassi, A.4
Dario, P.5
-
108
-
-
78651506596
-
Control electronics integration toward endoscopic capsule robot performing legged locomotion and illumination
-
Oct. 18-22, Taipei, Piscataway, NJ: IEEE
-
Alonso O, Freixas L, Canals J, Susilo E, Diegeuez A. 2008. Control electronics integration toward endoscopic capsule robot performing legged locomotion and illumination. Proc. IEEE/RSJ Int. Conf. Intell. Robots Syst., Oct. 18-22, Taipei, pp. 2798-803. Piscataway, NJ: IEEE
-
(2008)
Proc. IEEE/RSJ Int. Conf. Intell. Robots Syst.
, pp. 2798-2803
-
-
Alonso, O.1
Freixas, L.2
Canals, J.3
Susilo, E.4
Diegeuez, A.5
-
109
-
-
40649118247
-
Technology insight: Magnetic navigation in coronary interventions
-
Ramcharitar S, Patterson MS, van Geuns RJ, van Meighem C, Serruys PW. 2008. Technology insight: magnetic navigation in coronary interventions. Nat. Clin. Pract. Cardiovasc. Med. 5:148-56
-
(2008)
Nat. Clin. Pract. Cardiovasc. Med.
, vol.5
, pp. 148-156
-
-
Ramcharitar, S.1
Patterson, M.S.2
Van Geuns, R.J.3
Van Meighem, C.4
Serruys, P.W.5
-
112
-
-
79551570334
-
Magnetically controllable gastrointestinal steering of video capsules
-
Carpi F, Kastelein N, Talcott M, Pappone C. 2011. Magnetically controllable gastrointestinal steering of video capsules. IEEE Trans. Biomed. Eng. 58(2):231-34
-
(2011)
IEEE Trans. Biomed. Eng.
, vol.58
, Issue.2
, pp. 231-234
-
-
Carpi, F.1
Kastelein, N.2
Talcott, M.3
Pappone, C.4
-
113
-
-
78650534654
-
Inspection of the human stomach using remote-controlled capsule endoscopy: A feasibility study in healthy volunteers (with videos)
-
Keller J, Fibbe C, Volke F, Gerber J, Mosse AC, et al. 2011. Inspection of the human stomach using remote-controlled capsule endoscopy: a feasibility study in healthy volunteers (with videos). Gastrointest. Endosc. 73(1):22-28
-
(2011)
Gastrointest. Endosc.
, vol.73
, Issue.1
, pp. 22-28
-
-
Keller, J.1
Fibbe, C.2
Volke, F.3
Gerber, J.4
Mosse, A.C.5
-
114
-
-
84855855944
-
Blinded nonrandomized comparative study of gastric examination with a magnetically guided capsule endoscope and standard videoendoscope
-
Rey JF, Ogata H, Hosoe N, Ohtsuka K, Ogata N, et al. 2012. Blinded nonrandomized comparative study of gastric examination with a magnetically guided capsule endoscope and standard videoendoscope. Gastrointest. Endosc. 75(2):373-81
-
(2012)
Gastrointest. Endosc.
, vol.75
, Issue.2
, pp. 373-381
-
-
Rey, J.F.1
Ogata, H.2
Hosoe, N.3
Ohtsuka, K.4
Ogata, N.5
-
115
-
-
76349086056
-
Robotic versus manual control in magnetic steering of an endoscopic capsule
-
Ciuti G, Donlin R, Valdastri P, Arezzo A, Menciassi A, et al. 2010. Robotic versus manual control in magnetic steering of an endoscopic capsule. Endoscopy 42(2):148-52
-
(2010)
Endoscopy
, vol.42
, Issue.2
, pp. 148-152
-
-
Ciuti, G.1
Donlin, R.2
Valdastri, P.3
Arezzo, A.4
Menciassi, A.5
-
116
-
-
70349783406
-
Diamagnetically stabilized levitation control of an intraluminal magnetic capsule
-
Lam M, Mintchev M. 2009. Diamagnetically stabilized levitation control of an intraluminal magnetic capsule. Physiol. Meas. 30:763-77
-
(2009)
Physiol. Meas.
, vol.30
, pp. 763-777
-
-
Lam, M.1
Mintchev, M.2
-
117
-
-
77957602132
-
In vivo trial of a driving system for a self-propelling capsule endoscope using a magnetic field (with video)
-
Morita E, Ohtsuka N, Shindo Y, Nouda S, Kuramoto T, et al. 2010. In vivo trial of a driving system for a self-propelling capsule endoscope using a magnetic field (with video). Gastrointest. Endosc. 72(4):836-40
-
(2010)
Gastrointest. Endosc.
, vol.72
, Issue.4
, pp. 836-840
-
-
Morita, E.1
Ohtsuka, N.2
Shindo, Y.3
Nouda, S.4
Kuramoto, T.5
-
118
-
-
34250583541
-
Intraluminal biopsy of the small intestine
-
Crosby WH, Kugler HW. 1957. Intraluminal biopsy of the small intestine. Dig. Dis. Sci. 2(5): 236-41
-
(1957)
Dig. Dis. Sci.
, vol.2
, Issue.5
, pp. 236-241
-
-
Crosby, W.H.1
Kugler, H.W.2
-
119
-
-
79957988670
-
A rotationalmicro biopsy device for the capsule endoscope
-
Aug. 2-6, Edmonton, Can., Piscataway, NJ: IEEE
-
Kong K, Cha J, JeonD, Cho DD. 2005. A rotationalmicro biopsy device for the capsule endoscope. Proc. IEEE/RSJ Int. Conf. Intell. Robots Syst., Aug. 2-6, Edmonton, Can., pp. 1839-43. Piscataway, NJ: IEEE
-
(2005)
Proc. IEEE/RSJ Int. Conf. Intell. Robots Syst.
, pp. 1839-1843
-
-
Kong, K.1
Cha, J.2
Jeond Cho, D.D.3
-
120
-
-
42549084605
-
A novel microactuator for microbiopsy in capsular endoscopes
-
Park S, Koo K, Bang SM, Park JY, Song SY, Cho DD. 2008. A novel microactuator for microbiopsy in capsular endoscopes. J. Micromech. Microeng. 18:025032
-
(2008)
J. Micromech. Microeng.
, vol.18
, pp. 025032
-
-
Park, S.1
Koo, K.2
Bang, S.M.3
Park, J.Y.4
Song, S.Y.5
Cho, D.D.6
-
121
-
-
84930196481
-
Magnetic mechanism for wireless capsule biopsy
-
Simi M, Gerboni G, Menciassi A, Valdastri P. 2012. Magnetic mechanism for wireless capsule biopsy. J. Med. Devices. 6(1):017611
-
(2012)
J. Med. Devices.
, vol.6
, Issue.1
, pp. 017611
-
-
Simi, M.1
Gerboni, G.2
Menciassi, A.3
Valdastri, P.4
-
122
-
-
79952287117
-
Localization of magnetic pills
-
Laulicht B, Gidmark NJ, Tripathi E, Mathiowitz E. 2011. Localization of magnetic pills. Proc. Natl. Acad. Sci. USA 108(6):2252-57
-
(2011)
Proc. Natl. Acad. Sci. USA
, vol.108
, Issue.6
, pp. 2252-2257
-
-
Laulicht, B.1
Gidmark, N.J.2
Tripathi, E.3
Mathiowitz, E.4
-
123
-
-
0034959307
-
Evaluation of the Intelisite capsule to deliver theophylline and frusemide tablets to the small intestine and colon
-
DOI 10.1016/S0928-0987(01)00134-8, PII S0928098701001348
-
ClearNJ, Milton A, Humphrey M, Henry BT, Wulff M, et al. 2001. Evaluation of the Intelisite capsule to deliver theophylline and frusemide tablets to the small intestine and colon. Eur. J. Pharm. Sci. 13:375-84 (Pubitemid 32618646)
-
(2001)
European Journal of Pharmaceutical Sciences
, vol.13
, Issue.4
, pp. 375-384
-
-
Clear, N.J.1
Milton, A.2
Humphrey, M.3
Henry, B.T.4
Wulff, M.5
Nichols, D.J.6
Anziano, R.J.7
Wilding, I.8
-
124
-
-
0034325383
-
Development of a new engineering-based capsule for human drug absorption studies
-
Wilding I, Hirst P, Connor A. 2000. Development of a new engineering-based capsule for human drug absorption studies. Pharm. Sci. Technol. Today 3:385-92
-
(2000)
Pharm. Sci. Technol. Today
, vol.3
, pp. 385-392
-
-
Wilding, I.1
Hirst, P.2
Connor, A.3
-
126
-
-
84857030080
-
Design and rolling locomotion of a magnetically actuated soft capsule endoscope
-
Yim S, Sitti M. 2012. Design and rolling locomotion of a magnetically actuated soft capsule endoscope. IEEE Trans. Robot. 28(1):183-94
-
(2012)
IEEE Trans. Robot.
, vol.28
, Issue.1
, pp. 183-194
-
-
Yim, S.1
Sitti, M.2
-
127
-
-
77954312067
-
A novel micro-fabricated thruster for drug release in remote controlled capsule
-
Pi X, Lin Y, Wei K, Liu H, Wang G, et al. 2010. A novel micro-fabricated thruster for drug release in remote controlled capsule. Sens. Actuators A 159(2):227-32
-
(2010)
Sens. Actuators A
, vol.159
, Issue.2
, pp. 227-232
-
-
Pi, X.1
Lin, Y.2
Wei, K.3
Liu, H.4
Wang, G.5
-
128
-
-
80055074935
-
Mucoadhesive film for anchoring assistive surgical instruments in endoscopic surgery: In vivo assessment of deployment and attachment
-
Pensabene V, Valdastri P, Tognarelli S, Menciassi A, Arezzo A, Dario P. 2011. Mucoadhesive film for anchoring assistive surgical instruments in endoscopic surgery: in vivo assessment of deployment and attachment. Surg. Endosc. 25(9):3071-79
-
(2011)
Surg. Endosc.
, vol.25
, Issue.9
, pp. 3071-3079
-
-
Pensabene, V.1
Valdastri, P.2
Tognarelli, S.3
Menciassi, A.4
Arezzo, A.5
Dario, P.6
-
129
-
-
78650851775
-
An ingestible wireless capsule for treatment of obesity
-
Aug. 31-Sept. 4, Buenos Aires, Piscataway, NJ: IEEE
-
Kencana AP, Rasouli M, Huynh VA, Ting EK, Lai JCY, et al. 2010. An ingestible wireless capsule for treatment of obesity. Proc. 32nd Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., Aug. 31-Sept. 4, Buenos Aires, pp. 963-66. Piscataway, NJ: IEEE
-
(2010)
Proc. 32nd Annu. Int. Conf. IEEE Eng. Med. Biol. Soc.
, pp. 963-966
-
-
Kencana, A.P.1
Rasouli, M.2
Huynh, V.A.3
Ting, E.K.4
Jcy, L.5
-
130
-
-
33750362439
-
Progress in three-dimensional (3D) Li-ion microbatteries
-
DOI 10.1016/j.ssi.2006.02.048, PII S0167273806001172
-
Golodnitsky D, Nathan M, Yufit V, Strauss E, Freedman K, et al. 2006. Progress in three-dimensional (3D) Li-ion microbatteries. Solid State Ionics 177(26-32):2811-19 (Pubitemid 44634043)
-
(2006)
Solid State Ionics
, vol.177
, Issue.26-32 SPEC. ISS.
, pp. 2811-2819
-
-
Golodnitsky, D.1
Nathan, M.2
Yufit, V.3
Strauss, E.4
Freedman, K.5
Burstein, L.6
Gladkich, A.7
Peled, E.8
-
131
-
-
34447309715
-
Wireless power transfer via strongly coupled magnetic resonances
-
DOI 10.1126/science.1143254
-
Kurs A, Karalis A, Moffatt R, Joannopoulos JD, Fisher P, Soljačić M. 2007. Wireless power transfer via strongly coupled magnetic resonances. Science 317(5834):83-86 (Pubitemid 47056459)
-
(2007)
Science
, vol.317
, Issue.5834
, pp. 83-86
-
-
Kurs, A.1
Karalis, A.2
Moffatt, R.3
Joannopoulos, J.D.4
Fisher, P.5
Soljacic, M.6
-
132
-
-
70350422333
-
Wireless powering for a self-propelled and steerable endoscopic capsule for stomach inspection
-
Carta R, Tortora G, Thon?e J, Lenaerts B, Valdastri P, et al. 2009. Wireless powering for a self-propelled and steerable endoscopic capsule for stomach inspection. Biosens. Bioelectron. 25:845-51
-
(2009)
Biosens. Bioelectron.
, vol.25
, pp. 845-851
-
-
Carta, R.1
Tortora, G.2
Thone, J.3
Lenaerts, B.4
Valdastri, P.5
-
133
-
-
77954841219
-
A method for improving the wireless power transmission efficiency of an endoscopic capsule based on electromagnetic localization and synthesis of magnetic field vector
-
Li H, Yan G, Gao P. 2010. A method for improving the wireless power transmission efficiency of an endoscopic capsule based on electromagnetic localization and synthesis of magnetic field vector. Proc. Inst. Mech. Eng. C 224(7):1463-71
-
(2010)
Proc. Inst. Mech. Eng. C
, vol.224
, Issue.7
, pp. 1463-1471
-
-
Li, H.1
Yan, G.2
Gao, P.3
-
134
-
-
78650812098
-
Toward tetherless insufflation of the GI tract
-
Aug. 31-Sept. 4, Buenos Aires, Piscataway, NJ: IEEE
-
Toennies JL, Ciuti G, Smith BF, Menciassi A, Valdastri P, Webster RJ. 2010. Toward tetherless insufflation of the GI tract. Proc. 32nd Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., Aug. 31-Sept. 4, Buenos Aires, pp. 1946-49. Piscataway, NJ: IEEE
-
(2010)
Proc. 32nd Annu. Int. Conf. IEEE Eng. Med. Biol. Soc.
, pp. 1946-1949
-
-
Toennies, J.L.1
Ciuti, G.2
Smith, B.F.3
Menciassi, A.4
Valdastri, P.5
Webster, R.J.6
-
135
-
-
37249063857
-
Culture of insect cells contracting spontaneously; research moving toward an environmentally robust hybrid robotic system
-
DOI 10.1016/j.jbiotec.2007.08.042, PII S0168165607015301, System Cell Engineering by Multi-Scale Manipulation
-
Akiyama Y, Iwabuchi K, Furukawa Y, Morishima K. 2008. Culture of insect cells contracting spontaneously; research moving toward an environmentally robust hybrid robotic system. J. Biotechnol. 133(2):261-66 (Pubitemid 350266908)
-
(2008)
Journal of Biotechnology
, vol.133
, Issue.2
, pp. 261-266
-
-
Akiyama, Y.1
Iwabuchi, K.2
Furukawa, Y.3
Morishima, K.4
|