메뉴 건너뛰기




Volumn 8, Issue 3, 2004, Pages 271-278

An implantable telemetry platform system for in vivo monitoring of physiological parameters

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER AIDED DIAGNOSIS; DATA ACQUISITION; DATA COMMUNICATION SYSTEMS; DIGITAL COMMUNICATION SYSTEMS; MICROCONTROLLERS; MICROSENSORS; PHYSIOLOGY; TELEMETERING EQUIPMENT; WIRELESS TELECOMMUNICATION SYSTEMS;

EID: 4644277489     PISSN: 10897771     EISSN: None     Source Type: Journal    
DOI: 10.1109/TITB.2004.834389     Document Type: Article
Times cited : (101)

References (17)
  • 1
    • 0036559959 scopus 로고    scopus 로고
    • Golden accomplishments in biomedical engineering
    • May/June
    • F. Nebeker, "Golden accomplishments in biomedical engineering," IEEE Eng. Med. Biol. Mag., vol. 21, pp. 17-47, May/June 2002.
    • (2002) IEEE Eng. Med. Biol. Mag. , vol.21 , pp. 17-47
    • Nebeker, F.1
  • 2
    • 1242349874 scopus 로고
    • Radio telemetering from within the human body
    • R. S. Mackay and B. Jacobson, "Radio telemetering from within the human body," Science, vol. 134, pp. 1196-1202, 1961.
    • (1961) Science , vol.134 , pp. 1196-1202
    • Mackay, R.S.1    Jacobson, B.2
  • 3
    • 4644248269 scopus 로고
    • Echo capsule for medical use (A batteryless endoradiosonde)
    • J. Nagumo et al., "Echo capsule for medical use (A batteryless endoradiosonde)," IRE Trans. Bio-Med. Electronics, vol. BME-9, pp. 195-202, 1962.
    • (1962) IRE Trans. Bio-Med. Electronics , vol.BME-9 , pp. 195-202
    • Nagumo, J.1
  • 4
    • 0034576886 scopus 로고    scopus 로고
    • The development of the swallowable video capsule (M2A)
    • G. Meron, "The development of the swallowable video capsule (M2A ," Gastrointestinal Endoscopy, vol. 6, pp. 817-8199, 2000.
    • (2000) Gastrointestinal Endoscopy , vol.6 , pp. 817-8199
    • Meron, G.1
  • 6
    • 84964689597 scopus 로고    scopus 로고
    • Design of bi-directional and multi-channel miniaturized telemetry module for wireless endoscopy
    • Madison, WI
    • H. J. Park et al., "Design of bi-directional and multi-channel miniaturized telemetry module for wireless endoscopy," in Proc. 2nd Int. IEEE-EMBS Conf. Microtechnologies in Medicine and Biology, Madison, WI, 2002, pp. 273-276.
    • (2002) Proc. 2nd Int. IEEE-EMBS Conf. Microtechnologies in Medicine and Biology , pp. 273-276
    • Park, H.J.1
  • 8
    • 0031260315 scopus 로고    scopus 로고
    • A single-channel implantable microstimulator for functional neuromuscular stimulation
    • Oct
    • B. Ziaie, M. D. Nardin, A. R. Coghlan, and K. Najafi, "A single-channel implantable microstimulator for functional neuromuscular stimulation," IEEE Trans. Biomed. Eng., vol. 44, pp. 909-920, Oct. 1997.
    • (1997) IEEE Trans. Biomed. Eng. , vol.44 , pp. 909-920
    • Ziaie, B.1    Nardin, M.D.2    Coghlan, A.R.3    Najafi, K.4
  • 9
    • 0028518589 scopus 로고
    • A telemetry-instrumentation system for monitoring multiple subcutaneously implanted glucose sensors
    • Oct
    • M. C. Shults, R. K. Rhodes, S. J. Updike, B. J. Gilligan, and W. N. Reining, "A telemetry-instrumentation system for monitoring multiple subcutaneously implanted glucose sensors," IEEE Trans. Biomed. Eng., vol. 41, pp. 937-947, Oct. 1994.
    • (1994) IEEE Trans. Biomed. Eng. , vol.41 , pp. 937-947
    • Shults, M.C.1    Rhodes, R.K.2    Updike, S.J.3    Gilligan, B.J.4    Reining, W.N.5
  • 10
    • 0024041578 scopus 로고
    • A telemetry-instrumentation system for chronically implanted glucose and oxygen sensors
    • July
    • B. D. McKean and D. A. Gough, "A telemetry-instrumentation system for chronically implanted glucose and oxygen sensors," IEEE Trans. Biomed. Eng., vol. BME-35, pp. 526-532, July 1988.
    • (1988) IEEE Trans. Biomed. Eng. , vol.BME-35 , pp. 526-532
    • McKean, B.D.1    Gough, D.A.2
  • 11
    • 4644309914 scopus 로고    scopus 로고
    • Endonetics, Inc., International Patent WO 00/59 376, Apr. 7
    • Endonetics, Inc., "Implantable Monitoring Probe," International Patent WO 00/59 376, Apr. 7, 2000.
    • (2000) Implantable Monitoring Probe
  • 12
    • 0030312249 scopus 로고    scopus 로고
    • Multichannel, programmable, microprocessor based strain gauge telemetry system
    • C. P. Townsend and S. W. Arms, "Multichannel, programmable, microprocessor based strain gauge telemetry system," in Proc. 18th Int. IEEE-EMBS Conf., vol. 1, 1996, pp. 293-294.
    • (1996) Proc. 18th Int. IEEE-EMBS Conf. , vol.1 , pp. 293-294
    • Townsend, C.P.1    Arms, S.W.2
  • 13
    • 0343375204 scopus 로고    scopus 로고
    • ICNIRP Guidelines, "Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)"
    • Apr
    • "ICNIRP Guidelines, "Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)"," Health Physics, vol. 74, pp. 494-522, Apr. 1998.
    • (1998) Health Physics , vol.74 , pp. 494-522
  • 14
    • 54949152106 scopus 로고
    • Electrical properties of tissues and cell suspensions
    • H. P. Schwan, "Electrical properties of tissues and cell suspensions," Adv. Phys. Medicine and Biology, vol. 5, pp. 147-209, 1957.
    • (1957) Adv. Phys. Medicine and Biology , vol.5 , pp. 147-209
    • Schwan, H.P.1
  • 16
    • 0034029915 scopus 로고    scopus 로고
    • Radiowave propagation from a tissue-implanted source at 418 MHz and 916.5 MHz
    • Apr
    • W. G. Scanlon, J. B. Burns, and N. E. Evans, "Radiowave propagation from a tissue-implanted source at 418 MHz and 916.5 MHz," IEEE Trans. Biomed. Eng., vol. 47, pp. 527-534, Apr. 2000.
    • (2000) IEEE Trans. Biomed. Eng. , vol.47 , pp. 527-534
    • Scanlon, W.G.1    Burns, J.B.2    Evans, N.E.3
  • 17
    • 4644353148 scopus 로고    scopus 로고
    • High-pressure balloon catheter for real-time pressure monitoring in the esophagus
    • Sept
    • K. Y. Kwan, K. V. Kaler, and M. P. Mintchev, "High-pressure balloon catheter for real-time pressure monitoring in the esophagus," in Proc. 9th Int. Conf. Electronic, Circuit and Systems, vol. 3, Sept. 2002, pp. 1211-1214.
    • (2002) Proc. 9th Int. Conf. Electronic, Circuit and Systems , vol.3 , pp. 1211-1214
    • Kwan, K.Y.1    Kaler, K.V.2    Mintchev, M.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.