메뉴 건너뛰기




Volumn 141, Issue 2, 2008, Pages 432-439

Wearable magnetic locating and tracking system for MEMS medical capsule

Author keywords

Magnetic dipole; Magnetic locating and tracking; MEMS medical capsule

Indexed keywords

BIOMEDICAL EQUIPMENT; DATA PROCESSING; DRUG DELIVERY; MAGNETIC FIELDS; MAGNETIC MOMENTS; MEMS;

EID: 38149025437     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2007.10.051     Document Type: Article
Times cited : (57)

References (12)
  • 1
    • 18144418140 scopus 로고    scopus 로고
    • Development of a magnetic capsule as a drug release system for future applications in the human GI tract
    • Richert H., Surzhenko O., Wangemann S., et al. Development of a magnetic capsule as a drug release system for future applications in the human GI tract. J. Magn. Magn. Mater. 293 (2005) 497-500
    • (2005) J. Magn. Magn. Mater. , vol.293 , pp. 497-500
    • Richert, H.1    Surzhenko, O.2    Wangemann, S.3
  • 2
    • 38149046814 scopus 로고    scopus 로고
    • P. Xitian, Z. Xiaolin, P. Chenlin, A novel remote controlled capsule for human drug absorption studies, in: Proceedings of the 27th Annual International Conference of the IEEE EMBC'05.
  • 3
    • 13244265791 scopus 로고    scopus 로고
    • A non-invasive method for gastrointestinal parameter monitering
    • Wang W., Yan G., Sun F., et al. A non-invasive method for gastrointestinal parameter monitering. World Gastroenterol. 11 (2005) 521-524
    • (2005) World Gastroenterol. , vol.11 , pp. 521-524
    • Wang, W.1    Yan, G.2    Sun, F.3
  • 4
    • 27644446902 scopus 로고    scopus 로고
    • The ESO-PILL: a non-invasive MEMS capsule for Bolus Transit Monitoring in the Esophagus
    • Tel Aviv, Israel
    • Jui Y.T., Sadowki, Kaler K.V.I.S., and Mintchev M.P. The ESO-PILL: a non-invasive MEMS capsule for Bolus Transit Monitoring in the Esophagus. Proceedings of the IEEE ICECS. Tel Aviv, Israel (2004) 427-430
    • (2004) Proceedings of the IEEE ICECS , pp. 427-430
    • Jui, Y.T.1    Sadowki2    Kaler, K.V.I.S.3    Mintchev, M.P.4
  • 6
    • 0033135633 scopus 로고    scopus 로고
    • Imaging technologys for assessing drug delivery in man
    • Newman S.P., and Wilding l.R. Imaging technologys for assessing drug delivery in man. Pharm. Sci. Technol. Today 2 5 (1999) 181-189
    • (1999) Pharm. Sci. Technol. Today , vol.2 , Issue.5 , pp. 181-189
    • Newman, S.P.1    Wilding, l.R.2
  • 7
    • 38149067756 scopus 로고    scopus 로고
    • G. Polvani, Medical magnetic positioning system and method for determining the position of a magnetic probe, US Patent 5,762,064.
  • 8
    • 0035425763 scopus 로고    scopus 로고
    • Tracking system with five degrees of freedom using a 2D-array of Hall sensors and a permanent magnetic
    • Schlageter V., Besse P.-A., Popvic R.S., and Kucera P. Tracking system with five degrees of freedom using a 2D-array of Hall sensors and a permanent magnetic. Sens. Actuators A 92 (2001) 37-42
    • (2001) Sens. Actuators A , vol.92 , pp. 37-42
    • Schlageter, V.1    Besse, P.-A.2    Popvic, R.S.3    Kucera, P.4
  • 9
    • 0004169367 scopus 로고    scopus 로고
    • Chinese Science Press, The McGraw-Hill Companies Inc. p. 605, Chapter 7
    • Kovacs G.T.A. Micromachined Transducers Sourcebook (2003), Chinese Science Press, The McGraw-Hill Companies Inc. p. 605, Chapter 7
    • (2003) Micromachined Transducers Sourcebook
    • Kovacs, G.T.A.1
  • 11
    • 25844470352 scopus 로고    scopus 로고
    • Study of simplified magnetic-location model for micro medical device inside human body
    • 895-897+901
    • Wensheng H., Xiaolin Z., and Chenglin P. Study of simplified magnetic-location model for micro medical device inside human body. Yi Qi Yi Biao Xue Bao/Chin. J. Sci. Instrum. 26 (2005) 895-897+901
    • (2005) Yi Qi Yi Biao Xue Bao/Chin. J. Sci. Instrum. , vol.26
    • Wensheng, H.1    Xiaolin, Z.2    Chenglin, P.3
  • 12
    • 38149060604 scopus 로고    scopus 로고
    • Target positioning and parameter estimation based on magnetic dipole model
    • Jinfei T., Senguang G., and Jingen W. Target positioning and parameter estimation based on magnetic dipole model. Acta Eletron. 30 (2002) 614-616
    • (2002) Acta Eletron. , vol.30 , pp. 614-616
    • Jinfei, T.1    Senguang, G.2    Jingen, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.