메뉴 건너뛰기




Volumn 25, Issue 7, 2012, Pages 925-934

How the signal-to-noise ratio influences hyperpolarized 13C dynamic MRS data fitting and parameter estimation

Author keywords

Dynamic MRS; Hyperpolarized nuclei; in vivo cardiac metabolism; Kinetic model; MRS; Signal to noise ratio

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; KINETIC PARAMETERS; KINETIC THEORY; METABOLISM; METABOLITES; MONTE CARLO METHODS; PARAMETER ESTIMATION; SIGNAL ANALYSIS;

EID: 84862313772     PISSN: 09523480     EISSN: 10991492     Source Type: Journal    
DOI: 10.1002/nbm.1813     Document Type: Article
Times cited : (22)

References (43)
  • 2
    • 0020637873 scopus 로고
    • In vivo carbon-13 nuclear magnetic resonance studies of heart metabolism
    • Neurohr KJ, Barrett EJ, Shulman RG. In vivo carbon-13 nuclear magnetic resonance studies of heart metabolism. Proc. Natl. Acad. Sci. USA, 1983; 80: 1603-1607.
    • (1983) Proc. Natl. Acad. Sci. USA , vol.80 , pp. 1603-1607
    • Neurohr, K.J.1    Barrett, E.J.2    Shulman, R.G.3
  • 3
    • 0030058579 scopus 로고    scopus 로고
    • Metabolic compartmentation of lactate in the glucose-perfused rat heart
    • Chatham JC, Forder JR. Metabolic compartmentation of lactate in the glucose-perfused rat heart. Am. J. Physiol. 1996; 270: H224-H229.
    • (1996) Am. J. Physiol. , vol.270
    • Chatham, J.C.1    Forder, J.R.2
  • 28
    • 0034963583 scopus 로고    scopus 로고
    • MR spectroscopy quantitation: a review of time-domain methods
    • Vanhamme L, Sundin T, Van Hecke P, Van Huffel S. MR spectroscopy quantitation: a review of time-domain methods. NMR Biomed. 2001; 14: 233-246.
    • (2001) NMR Biomed. , vol.14 , pp. 233-246
    • Vanhamme, L.1    Sundin, T.2    Van Hecke, P.3    Van Huffel, S.4
  • 30
    • 0346308381 scopus 로고    scopus 로고
    • Improved method for accurate and efficient quantification of MRS data with use of prior knowledge
    • Vanhamme L, van den Boogaart A, Van Huffel S. Improved method for accurate and efficient quantification of MRS data with use of prior knowledge. J. Magn. Reson. 1997; 129: 35-43.
    • (1997) J. Magn. Reson. , vol.129 , pp. 35-43
    • Vanhamme, L.1    van den Boogaart, A.2    Van Huffel, S.3
  • 31
  • 40
    • 0033185631 scopus 로고    scopus 로고
    • Time-domain quantification of series of biomedical magnetic resonance spectroscopy signals
    • Vanhamme L, Van Huffel S, Van Hecke P, van Ormondt D. Time-domain quantification of series of biomedical magnetic resonance spectroscopy signals. J. Magn. Res. 1999; 140: 120-130.
    • (1999) J. Magn. Res. , vol.140 , pp. 120-130
    • Vanhamme, L.1    Van Huffel, S.2    Van Hecke, P.3    van Ormondt, D.4
  • 41
    • 0002479878 scopus 로고    scopus 로고
    • Cramer-Rao bound expressions for parametric estimation of overlapping peaks: influence of prior knowledge
    • Cavassila S, Deval S, Huegen C, van Ormondt D, Graveron-Demilly D. Cramer-Rao bound expressions for parametric estimation of overlapping peaks: influence of prior knowledge. J. Magn. Res. 2000; 143: 311-320.
    • (2000) J. Magn. Res. , vol.143 , pp. 311-320
    • Cavassila, S.1    Deval, S.2    Huegen, C.3    van Ormondt, D.4    Graveron-Demilly, D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.