메뉴 건너뛰기




Volumn 38, Issue 12, 2011, Pages 6513-6527

Calculation of k Q clin, Q msr f clin, f msr for several small detectors and for two linear accelerators using Monte Carlo simulations

Author keywords

correction factor; detector; Monte Carlo; output factor; small beams

Indexed keywords

DETECTORS; DIODES; FACTOR ANALYSIS; LINEAR ACCELERATORS; PHOTONS; UNCERTAINTY ANALYSIS;

EID: 82755163844     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3660770     Document Type: Article
Times cited : (147)

References (42)
  • 2
    • 0030050943 scopus 로고    scopus 로고
    • Characteristics of a dedicated linear accelerator-based stereotactic radiosurgery-radiotherapy unit
    • DOI 10.1016/0167-8140(95)01674-0
    • I. J. Das, M. B. Downes, B. W. Corn, B. J. Curran, M. W. Wasik, and D. W. Andrews, Characteristics of a dedicated linear accelerator-based stereotactic radiosurgery-radiotherapy unit., Radiother. Oncol. 38 (1), 61-68 (1996). 10.1016/0167-8140(95)01674-0 (Pubitemid 26040268)
    • (1996) Radiotherapy and Oncology , vol.38 , Issue.1 , pp. 61-68
    • Das, I.J.1    Downes, M.B.2    Corn, B.W.3    Curran, W.J.4    Werner-Wasik, M.5    Andrews, D.W.6
  • 4
    • 0032823683 scopus 로고    scopus 로고
    • Megavoltage CT on a tomotherapy system
    • DOI 10.1088/0031-9155/44/10/316, PII S0031915599042013
    • K. J. Ruchala, G. H. Olivera, E. A. Schloesser, and T. R. Mackie, Megavoltage CT on a tomotherapy system., Phys. Med. Biol. 44, 2597-2621 (1999). 10.1088/0031-9155/44/10/316 (Pubitemid 29484944)
    • (1999) Physics in Medicine and Biology , vol.44 , Issue.10 , pp. 2597-2621
    • Ruchala, K.J.1    Olivera, G.H.2    Schloesser, E.A.3    Mackie, T.R.4
  • 5
    • 0035889335 scopus 로고    scopus 로고
    • Intensity-modulated radiotherapy: Current status and issues of interest
    • DOI 10.1016/S0360-3016(01)01749-7, PII S0360301601017497
    • IMRT Collaborative Working Group, Intensity-modulated radiotherapy: Current status and issues of interest., Int. J. Radiat. Oncol., Biol., Phys. 51 (4), 880-914 (2001). 10.1016/S0360-3016(01)01749-7 (Pubitemid 33026420)
    • (2001) International Journal of Radiation Oncology Biology Physics , vol.51 , Issue.4 , pp. 880-914
    • Purdy, J.A.1
  • 6
    • 10744231470 scopus 로고    scopus 로고
    • Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee
    • DOI 10.1118/1.1591194
    • G. A. Ezzell, J. M. Galvin, D. Low, J. R. Palta, I. Rosen, M. B. Sharpe, P. Xia, Y. Xiao, L. Xing, and C. X. Yu, Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee., Med. Phys. 30 (8), 2089-2115 (2003). 10.1118/1.1591194 (Pubitemid 37022015)
    • (2003) Medical Physics , vol.30 , Issue.8 , pp. 2089-2115
    • Ezzell, G.A.1    Galvin, J.M.2    Low, D.3    Palta, J.R.4    Rosen, I.5    Sharpe, M.B.6    Xia, P.7    Xiao, Y.8    Xing, L.9    Yu, C.X.10
  • 7
    • 51849157038 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy for delivery of prostate radiotherapy: Comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy
    • 10.1016/j.ijrob2008.02.047
    • D. Palma, E. Vollans, K. James, S. Nakano, V. Moiseenko, R. Shaffer, M. McKenzie, J. Morris, and K. Otto, Volumetric modulated arc therapy for delivery of prostate radiotherapy: Comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy., Int. J. Radiat. Oncol., Biol., Phys. 72 (4), 996-1001 (2008). 10.1016/j.ijrobp.2008.02.047
    • (2008) Int. J. Radiat. Oncol., Biol., Phys. , vol.72 , Issue.4 , pp. 996-1001
    • Palma, D.1    Vollans, E.2    James, K.3    Nakano, S.4    Moiseenko, V.5    Shaffer, R.6    McKenzie, M.7    Morris, J.8    Otto, K.9
  • 8
    • 0038715482 scopus 로고    scopus 로고
    • An EGSnrc investigation of cavity theory for ion chambers measuring air kerma
    • DOI 10.1118/1.1573891
    • L. A. Buckley, I. Kawrakow, and D. W. O. Rogers, An EGSnrc investigation of cavity theory for ion chambers measuring air kerma., Med. Phys. 30 (6), 1211-1218 (2003). 10.1118/1.1573891 (Pubitemid 36735987)
    • (2003) Medical Physics , vol.30 , Issue.6 , pp. 1211-1218
    • Buckley, L.A.1    Kawrakow, I.2    Rogers, D.W.O.3
  • 9
    • 0032874911 scopus 로고    scopus 로고
    • AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
    • DOI 10.1118/1.598691
    • P. R. Almond, P. J. Biggs, B. M. Coursey, W. F. Hanson, M. S. Huq, R. Nath, and D. W. Rogers, AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams., Med. Phys. 26 (9), 1847-1870 (1999). 10.1118/1.598691 (Pubitemid 29442268)
    • (1999) Medical Physics , vol.26 , Issue.9 , pp. 1847-1870
    • Almond, P.R.1    Biggs, P.J.2    Coursey, B.M.3    Hanson, W.F.4    Huq, M.S.5    Nath, R.6    Rogers, D.W.O.7
  • 12
    • 0031956451 scopus 로고    scopus 로고
    • Use of a new type of radiochromic film, a new parallel-plate micro- chamber, MOSFETs, and TLD 800 microcubes in the dosimetry of small beams
    • DOI 10.1118/1.598227
    • P. Francescon, S. Cora, C. Cavedon, P. Scalchi, S. Reccanello, and F. Colombo, Use of a new type of radiochromic film, a new parallel-plate micro-chamber, MOSFETs, and TLD 800 microcubes in the dosimetry of small beams., Med. Phys. 25 (4), 503-511 (1998). 10.1118/1.598227 (Pubitemid 28178358)
    • (1998) Medical Physics , vol.25 , Issue.4 , pp. 503-511
    • Francescon, P.1    Cora, S.2    Cavedon, C.3    Scalchi, P.4    Reccanello, S.5    Colombo, F.6
  • 13
    • 4644300643 scopus 로고    scopus 로고
    • An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets
    • DOI 10.1118/1.1767691
    • R. Capote, F. Sanchez -Doblado, A. Leal, J. I. Lagares, R. Arrans, and G. H. Hartmann, An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets., Med. Phys. 31 (9), 2416-2422 (2004). 10.1118/1.1767691 (Pubitemid 39287855)
    • (2004) Medical Physics , vol.31 , Issue.9 , pp. 2416-2422
    • Capote, R.1    Sanchez-Doblado, F.2    Leal, A.3    Lagares, J.I.4    Arrans, R.5    Hartmann, G.H.6
  • 15
    • 34347212158 scopus 로고    scopus 로고
    • A new method for output factor determination in MLC shaped narrow beams
    • DOI 10.1016/j.ejmp.2007.03.002, PII S1120179707000099
    • F. Sanchez-Doblado, G. H. Hartmann, J. Pena, J. V. Rosello, G. Russiello, and D. M. Gonzalez -Castano, A new method for output factor determination in MLC shaped narrow beams., Phys. Medica 23 (2), 58-66 (2007). 10.1016/j.ejmp.2007.03.002 (Pubitemid 47001326)
    • (2007) Physica Medica , vol.23 , Issue.2 , pp. 58-66
    • Sanchez-Doblado, F.1    Hartmann, G.H.2    Pena, J.3    Rosello, J.V.4    Russiello, G.5    Gonzalez-Castano, D.M.6
  • 16
    • 34447336432 scopus 로고    scopus 로고
    • Measurement of output factors for small photon beams
    • DOI 10.1118/1.2734383
    • O. A. Sauer and J. Wilbert, Measurement of output factors for small photon beams., Med. Phys. 34 (6), 1983-1988 (2007). 10.1118/1.2734383 (Pubitemid 47055733)
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 1983-1988
    • Sauer, O.A.1    Wilbert, J.2
  • 17
    • 38849151519 scopus 로고    scopus 로고
    • Total scatter factors of small beams: A multidetector and Monte Carlo study
    • DOI 10.1118/1.2828195
    • P. Francescon, S. Cora, and C. Cavedon, Total scatter factors of small beams: A multidetector and Monte Carlo study., Med. Phys. 35 (2), 504-513 (2008). 10.1118/1.2828195 (Pubitemid 351190870)
    • (2008) Medical Physics , vol.35 , Issue.2 , pp. 504-513
    • Francescon, P.1    Cora, S.2    Cavedon, C.3
  • 18
    • 70049102550 scopus 로고    scopus 로고
    • Application of a Monte Carlo-based method for total scatter factors of small beams to new solid state micro-detectors
    • 10.1120/jacmv10i1.2939
    • P. Francescon, S. Cora, C. Cavedon, and P. Scalchi, Application of a Monte Carlo-based method for total scatter factors of small beams to new solid state micro-detectors., J. Appl. Clin. Med. Phys. 10 (1), 147-152 (2009). 10.1120/jacmp.v10i1.2939
    • (2009) J. Appl. Clin. Med. Phys. , vol.10 , Issue.1 , pp. 147-152
    • Francescon, P.1    Cora, S.2    Cavedon, C.3    Scalchi, P.4
  • 19
    • 78650046950 scopus 로고    scopus 로고
    • Modeling silicon diode dose response factors for small photon fields
    • 10.1088/0031-9155/55/24/002
    • K. Eklund and A. Ahnesjo, Modeling silicon diode dose response factors for small photon fields., Phys. Med. Biol. 55, 7411-7423 (2010). 10.1088/0031-9155/55/24/002
    • (2010) Phys. Med. Biol. , vol.55 , pp. 7411-7423
    • Eklund, K.1    Ahnesjo, A.2
  • 20
    • 52949151876 scopus 로고    scopus 로고
    • Using a Monte Carlo model to predict dosimetric properties of small radiotherapy photon fields
    • 10.1118/1.2975223
    • A. J. Scott, A. E. Nahum, and J. D. Fenwick, Using a Monte Carlo model to predict dosimetric properties of small radiotherapy photon fields., Med. Phys. 35 (10), 4671-4684 (2008). 10.1118/1.2975223
    • (2008) Med. Phys. , vol.35 , Issue.10 , pp. 4671-4684
    • Scott, A.J.1    Nahum, A.E.2    Fenwick, J.D.3
  • 21
    • 0036130664 scopus 로고    scopus 로고
    • Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters
    • DOI 10.1118/1.1446109
    • D. Sheikh-Bagheri and D. W. O. Rogers, Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters., Med. Phys. 29 (3), 379-390 (2002). 10.1118/1.1446109 (Pubitemid 34241161)
    • (2002) Medical Physics , vol.29 , Issue.3 , pp. 379-390
    • Sheikh-Bagheri, D.1    Rogers, D.W.O.2
  • 22
    • 1942420368 scopus 로고    scopus 로고
    • Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams
    • DOI 10.1118/1.1668551
    • A. Tzedakis, J. E. Damilakis, M. Mazonakis, J. Stratakis, H. Varveris, and N. Gourtsoyiannis, Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams., Med. Phys. 31 (4) 907-913 (2004). 10.1118/1.1668551 (Pubitemid 38508872)
    • (2004) Medical Physics , vol.31 , Issue.4 , pp. 907-913
    • Tzedakis, A.1    Damilakis, J.E.2    Mazonakis, M.3    Stratakis, J.4    Varveris, H.5    Gourtsoyiannis, N.6
  • 23
    • 25644452873 scopus 로고    scopus 로고
    • Influence of ion chamber response on in-air profile measurements in megavoltage photon beams
    • DOI 10.1118/1.2011090
    • E. Tonkopi, M. R. McEwen, B. R. B. Walters, and I. Kawrakow, Influence of ion chamber response on in-air profile measurements in megavoltage photon beams., Med. Phys. 32 (9), 2918-2927 (2005). 10.1118/1.2011090 (Pubitemid 41384089)
    • (2005) Medical Physics , vol.32 , Issue.9 , pp. 2918-2927
    • Tonkopi, E.1    McEwen, M.R.2    Walters, B.R.B.3    Kawrakow, I.4
  • 24
    • 67649625514 scopus 로고    scopus 로고
    • Monte Carlo modeling of small photon fields: Quantifying the impact of focal spot size on source occlusion and output factors, and exploring miniphantom design for small-field measurements
    • 10.1118/1.3152866
    • A. J. D. Scott, A. E. Nahum, and J. D. Fenwick, Monte Carlo modeling of small photon fields: Quantifying the impact of focal spot size on source occlusion and output factors, and exploring miniphantom design for small-field measurements., Med. Phys. 36 (7), 3132-3144 (2009). 10.1118/1.3152866
    • (2009) Med. Phys. , vol.36 , Issue.7 , pp. 3132-3144
    • Scott, A.J.D.1    Nahum, A.E.2    Fenwick, J.D.3
  • 25
    • 29144536882 scopus 로고    scopus 로고
    • Decoupling initial electron beam parameters for Monte Carlo photon beam modelling by removing beam-modifying filters from the beam path
    • DOI 10.1088/0031-9155/50/24/012, PII S0031915505027235
    • B. De Smedt, N. Reynaert, F. Flachet, M. Coghe, M. G. Thompson, L. Paelinck, G. Pittomvils, C. De Wagter, W. De Neve, and H. Thierens, Decoupling initial electron beam parameters for Monte Carlo photon beam modeling by removing beam-modifying filters from the beam path., Phys. Med. Biol. 50, 5935-5951 (2005). 10.1088/0031-9155/50/24/012 (Pubitemid 41795843)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.24 , pp. 5935-5951
    • De Smedt, B.1    Reynaert, N.2    Flachet, F.3    Coghe, M.4    Thompson, M.G.5    Paelinck, L.6    Pittomvils, G.7    De Wagter, C.8    De Neve, W.9    Thierens, H.10
  • 26
    • 72049111471 scopus 로고    scopus 로고
    • Simulation of large x-ray fields using independently measured source and geometry details
    • 10.1118/1.3259729
    • D. Sawkey and B. A. Faddegon, Simulation of large x-ray fields using independently measured source and geometry details., Med. Phys. 36 (12), 5622-5632 (2009). 10.1118/1.3259729
    • (2009) Med. Phys. , vol.36 , Issue.12 , pp. 5622-5632
    • Sawkey, D.1    Faddegon, B.A.2
  • 27
    • 61349126070 scopus 로고    scopus 로고
    • Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams
    • 10.1118/1.3070547
    • D. L. Sawkey and B. A. Faddegon, Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams., Med. Phys. 36 (3), 698-707 (2009). 10.1118/1.3070547
    • (2009) Med. Phys. , vol.36 , Issue.3 , pp. 698-707
    • Sawkey, D.L.1    Faddegon, B.A.2
  • 28
    • 46149116346 scopus 로고    scopus 로고
    • Influence of focal spot on characteristics of very small diameter radiosurgical beams
    • DOI 10.1118/1.2936335
    • E. Sham, J. Seuntjens, S. Devic, and E. B. Podgorsak, Influence of focal spot on characteristics of very small diameter radiosurgical beams., Med. Phys. 35 (7), 3317-3330 (2008). 10.1118/1.2936335 (Pubitemid 351904535)
    • (2008) Medical Physics , vol.35 , Issue.7 , pp. 3317-3330
    • Sham, E.1    Seuntjens, J.2    Devic, S.3    Podgorsak, E.B.4
  • 29
    • 33846615836 scopus 로고    scopus 로고
    • Estimation of the focal spot size and shape for a medical linear accelerator by Monte Carlo simulation
    • DOI 10.1118/1.2426407
    • L. L. W. Wang and K. Leszczynski, Estimation of the focal spot size and shape for a medical linear accelerator by Monte Carlo simulation., Med. Phys. 34 (2), 485-488 (2007). 10.1118/1.2426407 (Pubitemid 46185127)
    • (2007) Medical Physics , vol.34 , Issue.2 , pp. 485-488
    • Wang, L.L.W.1    Leszczynski, K.2
  • 30
    • 33847640090 scopus 로고    scopus 로고
    • Automatic determination of primary electron beam parameters in Monte Carlo simulation
    • DOI 10.1118/1.2514155
    • J. Pena, D. M. Gonzlez-Castao, F. Gmez, F. Snchez-Doblado, and G. H. Hartmann, Automatic determination of primary electron beam parameters in Monte Carlo simulation., Med. Phys. 34 (3), 1076-1084 (2007). 10.1118/1.2514155 (Pubitemid 46355642)
    • (2007) Medical Physics , vol.34 , Issue.3 , pp. 1076-1084
    • Pena, J.1    Gonzalez-Castano, D.M.2    Gomez, F.3    Sanchez-Doblado, F.4    Hartmann, G.H.5
  • 31
    • 78149447290 scopus 로고    scopus 로고
    • Monte Carlo calculations of kQ, the beam quality conversion factor
    • 10.1118/1.3495537
    • B. R. Muir and D. W. O. Rogers, Monte Carlo calculations of kQ, the beam quality conversion factor., Med. Phys. 37 (11), 5939-5950 (2010). 10.1118/1.3495537
    • (2010) Med. Phys. , vol.37 , Issue.11 , pp. 5939-5950
    • Muir, B.R.1    Rogers, D.W.O.2
  • 32
    • 78149290698 scopus 로고    scopus 로고
    • Investigation of systematic uncertainties in Monte Carlo-calculated beam quality correction factors
    • 10.1088/0031-9155/55/16/S04
    • J. Wulff, J. T. Heverhagen, K. Zink, and I. Kawrakow, Investigation of systematic uncertainties in Monte Carlo-calculated beam quality correction factors., Phys. Med. Biol. 55, 4481-4493 (2010). 10.1088/0031-9155/55/16/S04
    • (2010) Phys. Med. Biol. , vol.55 , pp. 4481-4493
    • Wulff, J.1    Heverhagen, J.T.2    Zink, K.3    Kawrakow, I.4
  • 33
    • 79961069191 scopus 로고    scopus 로고
    • Measured and Monte Carlo calculated kQ factors: Accuracy and comparison
    • 10.1118/1.3600697
    • B. R. Muir, M. R. McEwen, and D. W. O. Rogers, Measured and Monte Carlo calculated kQ factors: Accuracy and comparison., Med. Phys. 38 (8), 4600-4609 (2011). 10.1118/1.3600697
    • (2011) Med. Phys. , vol.38 , Issue.8 , pp. 4600-4609
    • Muir, B.R.1    McEwen, M.R.2    Rogers, D.W.O.3
  • 34
    • 77952340515 scopus 로고    scopus 로고
    • Measurements of ionization chamber absorbed dose kQ factors in megavoltage photon beams
    • 10.1118/1.3375895
    • M. R. McEwen, Measurements of ionization chamber absorbed dose kQ factors in megavoltage photon beams., Med. Phys. 37 (5), 2179-2193 (2010). 10.1118/1.3375895
    • (2010) Med. Phys. , vol.37 , Issue.5 , pp. 2179-2193
    • McEwen, M.R.1
  • 36
    • 41449107480 scopus 로고    scopus 로고
    • Efficiency improvements for ion chamber calculations in high energy photon beams
    • DOI 10.1118/1.2874554
    • J. Wulff, K. Zink, and I. Kawrakow, Efficiency improvements for ion chamber calculations in high energy photon beams., Med. Phys. 35 (4), 1328-1336 (2008). 10.1118/1.2874554 (Pubitemid 351457500)
    • (2008) Medical Physics , vol.35 , Issue.4 , pp. 1328-1336
    • Wulff, J.1    Zink, K.2    Kawrakow, I.3
  • 37
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    • DOI 10.1118/1.598917
    • I. Kawrakow, Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version., Med. Phys. 27 (3), 485-498 (2000). 10.1118/1.598917 (Pubitemid 30171797)
    • (2000) Medical Physics , vol.27 , Issue.3 , pp. 485-498
    • Kawrakow, I.1
  • 39
    • 7244223252 scopus 로고    scopus 로고
    • Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting
    • DOI 10.1118/1.1788912
    • I. Kawrakow, D. W. O. Rogers, and B. R. B. Walters, Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting., Med. Phys. 31 (10), 2883-2898 (2004). 10.1118/1.1788912 (Pubitemid 39431018)
    • (2004) Medical Physics , vol.31 , Issue.10 , pp. 2883-2898
    • Kawrakow, I.1    Rogers, D.W.O.2    Walters, B.R.B.3
  • 40
    • 0003982205 scopus 로고
    • International Commission in Radiation Units and Measurements, , ICRU Report No. 37 (ICRU Washington, DC).
    • International Commission in Radiation Units and Measurements, Stopping Powers for Electrons and Positrons., ICRU Report No. 37 (ICRU Washington, DC, 1984).
    • (1984) Stopping Powers for Electrons and Positrons
  • 41
    • 79953689907 scopus 로고    scopus 로고
    • A Monte Carlo method to evaluate the impact of positioning errors on detector response and quality correction factors in nonstandard beams
    • 10.1088/0031-9155/56/8/018
    • H. Bouchard, J. P. Seuntjens, J. Carrier, and I. Kawrakow, A Monte Carlo method to evaluate the impact of positioning errors on detector response and quality correction factors in nonstandard beams., Phys. Med. Biol. 56, 2617-2634 (2011). 10.1088/0031-9155/56/8/018
    • (2011) Phys. Med. Biol. , vol.56 , pp. 2617-2634
    • Bouchard, H.1    Seuntjens, J.P.2    Carrier, J.3    Kawrakow, I.4
  • 42
    • 37549052531 scopus 로고    scopus 로고
    • Small fields: Non-equilibrium radiation dosimetry
    • , 10.1118/1.2815356
    • I. J. Das, G. X. Ding, and A. Ahnesj, Small fields: Non-equilibrium radiation dosimetry., Med. Phys. 35 (1), 206-215 (2008). 10.1118/1.2815356
    • (2008) Med. Phys. , vol.35 , Issue.1 , pp. 206-215
    • Das, I.J.1    Ding, G.X.2    Ahnesj, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.