메뉴 건너뛰기




Volumn 38, Issue 8, 2011, Pages 4600-4609

Measured and Monte Carlo calculated kQ factors: Accuracy and comparison

Author keywords

dosimetry protocols; EGSnrc; measurements; Monte Carlo; W e

Indexed keywords

CALIBRATION; IONIZATION CHAMBERS; MEASUREMENT; MEDICAL PHYSICS; RELIABILITY ANALYSIS; UNCERTAINTY ANALYSIS;

EID: 79961069191     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3600697     Document Type: Article
Times cited : (56)

References (37)
  • 1
    • 77952340515 scopus 로고    scopus 로고
    • Q factors in megavoltage photon beams
    • 10.1118/1.3375895
    • Q factors in megavoltage photon beams., Med. Phys. 37, 2179-2193 (2010). 10.1118/1.3375895
    • (2010) Med. Phys. , vol.37 , pp. 2179-2193
    • McEwen, M.R.1
  • 2
    • 78149447290 scopus 로고    scopus 로고
    • Q, the beam quality conversion factor
    • 10.1118/1.3495537
    • Q, the beam quality conversion factor., Med. Phys. 37, 5939-5950 (2010). 10.1118/1.3495537
    • (2010) Med. Phys. , vol.37 , pp. 5939-5950
    • Muir, B.R.1    Rogers, D.W.O.2
  • 3
    • 0033002724 scopus 로고    scopus 로고
    • Absorbed dose beam quality correction factors k(Q) for the NE2571 chamber in a 5 MV and a 10 MV photon beam
    • DOI 10.1088/0031-9155/44/3/002, PII S0031915599953666
    • Q for the NE2571 chamber in a 5 MV and 10 MV photon beam., Phys. Med. Biol. 44, 647-663 (1999). 10.1088/0031-9155/44/3/002 (Pubitemid 29133059)
    • (1999) Physics in Medicine and Biology , vol.44 , Issue.3 , pp. 647-663
    • Palmans, H.1    Mondelaers, W.2    Thierens, H.3
  • 4
    • 0034500295 scopus 로고    scopus 로고
    • Absorbed-dose beam quality conversion factors for cylindrical chambers in high energy photon beams
    • DOI 10.1118/1.1328081
    • J. P. Seuntjens, C. K. Ross, K. R. Shortt, and D. W. O. Rogers, Absorbed-dose beam quality conversion factors for cylindrical chambers in high-energy photon beams., Med. Phys. 27, 2763-2779 (2000). 10.1118/1.1328081 (Pubitemid 32063456)
    • (2000) Medical Physics , vol.27 , Issue.12 , pp. 2763-2779
    • Seuntjens, J.P.1    Ross, C.K.2    Shortt, K.R.3    Rogers, D.W.O.4
  • 7
    • 36048968264 scopus 로고    scopus 로고
    • Q factors for NE 2561 and NE 2571 ionization chambers in 5 cm × 5 cm and 10 cm × 10 cm radiotherapy beams of 8 MV and 16 MV photons
    • DOI 10.1088/0031-9155/52/20/011, PII S0031915507562111
    • Q factors for NE 2561 and NE 2571 ionization chambers in 5 cm 5 cm and 10 cm 10 cm radiotherapy beams of 8 MV and 16 MV photons., Phys. Med. Biol. 52, 6243-6259 (2007). 10.1088/0031-9155/52/20/011 (Pubitemid 350093192)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.20 , pp. 6243-6259
    • Krauss, A.1    Kapsch, R.-P.2
  • 12
    • 0029031216 scopus 로고
    • Q, for ionization chambers used in photon and electron dosimetry
    • 10.1088/0031-9155/40/7/003
    • Q, for ionization chambers used in photon and electron dosimetry., Phys. Med. Biol. 40, 1177-1190 (1995). 10.1088/0031-9155/40/7/003
    • (1995) Phys. Med. Biol. , vol.40 , pp. 1177-1190
    • Guerra, A.S.1    Laitano, R.F.2    Pimpinella, M.3
  • 14
    • 41449107480 scopus 로고    scopus 로고
    • Efficiency improvements for ion chamber calculations in high energy photon beams
    • DOI 10.1118/1.2874554
    • J. Wulff, K. Zink, and I. Kawrakow, Efficiency improvements for ion chamber calculations in high energy photon beams., Med. Phys. 35, 1328-1336 (2008). 10.1118/1.2874554 (Pubitemid 351457500)
    • (2008) Medical Physics , vol.35 , Issue.4 , pp. 1328-1336
    • Wulff, J.1    Zink, K.2    Kawrakow, I.3
  • 15
    • 84867314966 scopus 로고    scopus 로고
    • The EGSnrc Code System: Monte Carlo simulation of electron and photon transport
    • (National Research Council of Canada, Ottawa, Canada)
    • I. Kawrakow and D. W. O. Rogers, The EGSnrc Code System: Monte Carlo simulation of electron and photon transport., Technical Report PIRS-701 (National Research Council of Canada, Ottawa, Canada, 2007).
    • (2007) Technical Report PIRS-701
    • Kawrakow, I.1    Rogers, D.W.O.2
  • 16
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    • DOI 10.1118/1.598917
    • I. Kawrakow, Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version., Med. Phys. 27, 485-498 (2000). 10.1118/1.598917 (Pubitemid 30171797)
    • (2000) Medical Physics , vol.27 , Issue.3 , pp. 485-498
    • Kawrakow, I.1
  • 17
    • 45749111374 scopus 로고    scopus 로고
    • Monte-Carlo-based perturbation and beam quality correction factors for thimble ionization chambers in high-energy photon beams
    • DOI 10.1088/0031-9155/53/11/005, PII S0031915508724370
    • J. Wulff, J. T. Heverhagen, and K. Zink, Monte-Carlo-based perturbation and beam quality correction factors for thimble ionization chambers in high-energy photon beams., Phys. Med. Biol. 53, 2823-2836 (2008). 10.1088/0031-9155/53/11/005 (Pubitemid 351868608)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.11 , pp. 2823-2836
    • Wulff, J.1    Heverhagen, J.T.2    Zink, K.3
  • 18
    • 70349774702 scopus 로고    scopus 로고
    • The determination of beam quality correction factors: Monte Carlo simulations and measurements
    • 10.1088/0031-9155/54/15/006
    • D. M. Gonzlez-Castao, G. H. Hartmann, F. Snchez-Doblado, F. Gmez, R.-P. Kapsch, J. Pena, and R. Capote, The determination of beam quality correction factors: Monte Carlo simulations and measurements., Phys. Med. Biol. 54, 4723-4741 (2009). 10.1088/0031-9155/54/15/006
    • (2009) Phys. Med. Biol. , vol.54 , pp. 4723-4741
    • Gonzlez-Castao, D.M.1    Hartmann, G.H.2    Snchez-Doblado, F.3    Gmez, F.4    Kapsch, R.-P.5    Pena, J.6    Capote, R.7
  • 19
    • 0032874911 scopus 로고    scopus 로고
    • AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
    • DOI 10.1118/1.598691
    • P. R. Almond, P. J. Biggs, B. M. Coursey, W. F. Hanson, M. S. Huq, R. Nath, and D. W. O. Rogers, AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams., Med. Phys. 26, 1847-1870 (1999). 10.1118/1.598691 (Pubitemid 29442268)
    • (1999) Medical Physics , vol.26 , Issue.9 , pp. 1847-1870
    • Almond, P.R.1    Biggs, P.J.2    Coursey, B.M.3    Hanson, W.F.4    Huq, M.S.5    Nath, R.6    Rogers, D.W.O.7
  • 20
    • 79961062770 scopus 로고    scopus 로고
    • IAEA, Absorbed dose determination in external beam radiotherapy: An international code of practice for dosimetry based on standards of absorbed dose to water, Vol.398 of Technical Report Series (IAEA, Vienna)
    • IAEA, Absorbed dose determination in external beam radiotherapy: An international code of practice for dosimetry based on standards of absorbed dose to water, Vol.398 of Technical Report Series (IAEA, Vienna, 2001).
    • (2001)
  • 21
    • 0035739254 scopus 로고    scopus 로고
    • The relative response of NE2561 and NE2611A ionization chambers in megavoltage x-ray beams
    • DOI 10.1088/0031-9155/46/12/313, PII S0031915501262885
    • J. F. Boas, R. B. Huntley, and D. V. Webb, The relative response of NE2561 and NE2611A ionization chambers in megavoltage X-ray beams., Phys. Med. Biol. 46, 3259-3267 (2001). 10.1088/0031-9155/46/12/313 (Pubitemid 34568071)
    • (2001) Physics in Medicine and Biology , vol.46 , Issue.12 , pp. 3259-3267
    • Boas, J.F.1    Huntley, R.B.2    Webb, D.V.3
  • 22
    • 85027236690 scopus 로고    scopus 로고
    • Recent activities in measurement standards and dosimetry at ARPANSA, 2003-2005
    • (BIPM, Svres, France)
    • D. Webb, D. Butler, and C. Oliver, Recent activities in measurement standards and dosimetry at ARPANSA, 2003-2005., BIPM document CCRI(1)/05-02 (BIPM, Svres, France, 2005).
    • (2005) BIPM Document CCRI(1)/05-02
    • Webb, D.1    Butler, D.2    Oliver, C.3
  • 24
    • 0036130665 scopus 로고    scopus 로고
    • Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code
    • DOI 10.1118/1.1445413
    • D. Sheikh-Bagheri and D. W. O. Rogers, Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code., Med. Phys. 29, 391-402 (2002). 10.1118/1.1445413 (Pubitemid 34241162)
    • (2002) Medical Physics , vol.29 , Issue.3 , pp. 391-402
    • Sheikh-Bagheri, D.1    Rogers, D.W.O.2
  • 25
    • 25644452873 scopus 로고    scopus 로고
    • Influence of ion chamber response on in-air profile measurements in megavoltage photon beams
    • DOI 10.1118/1.2011090
    • E. Tonkopi, M. McEwen, B. Walters, and I. Kawrakow, Influence of ion chamber response on in-air profile measurements in megavoltage photon beams., Med. Phys. 32, 2918-2927 (2005). 10.1118/1.2011090 (Pubitemid 41384089)
    • (2005) Medical Physics , vol.32 , Issue.9 , pp. 2918-2927
    • Tonkopi, E.1    McEwen, M.R.2    Walters, B.R.B.3    Kawrakow, I.4
  • 26
    • 44649089043 scopus 로고    scopus 로고
    • Modeling ionization chamber response to nonstandard beam configurations
    • 10.1088/1742-6596/102/1/012023
    • L. Tantot and J. P. Seuntjens, Modeling ionization chamber response to nonstandard beam configurations., J. Phys.: Conf. Ser. 102, 012023 (2008). 10.1088/1742-6596/102/1/012023
    • (2008) J. Phys.: Conf. Ser. , vol.102 , pp. 012023
    • Tantot, L.1    Seuntjens, J.P.2
  • 27
    • 0026665730 scopus 로고
    • The effect of waterproofing sleeves on ionization chamber response
    • 10.1088/0031-9155/37/6/017
    • C. K. Ross and K. R. Shortt, The effect of waterproofing sleeves on ionization chamber response., Phys. Med. Biol. 37, 1403-1411 (1992). 10.1088/0031-9155/37/6/017
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1403-1411
    • Ross, C.K.1    Shortt, K.R.2
  • 28
    • 31844450298 scopus 로고    scopus 로고
    • wall, for thimble ionization chambers
    • DOI 10.1118/1.2161403
    • wall, for thimble ionization chambers., Med. Phys. 33, 455-464 (2006). 10.1118/1.2161403 (Pubitemid 43183990)
    • (2006) Medical Physics , vol.33 , Issue.2 , pp. 455-464
    • Buckley, L.A.1    Rogers, D.W.O.2
  • 29
    • 85092677784 scopus 로고    scopus 로고
    • Q factors, ion recombination, polarity and sleeve effects of Farmer type chambers calibrated in terms of absorbed dose to water at NPL
    • (NPL, Teddington, UK)
    • Q factors, ion recombination, polarity and sleeve effects of Farmer type chambers calibrated in terms of absorbed dose to water at NPL., 11th Radiotherapy Standards Users' Group meeting, (NPL, Teddington, UK, 2008).
    • (2008) 11th Radiotherapy Standards Users' Group Meeting
    • Thomas, R.1    Duane, S.2    Simon, M.3
  • 30
    • 42949146907 scopus 로고    scopus 로고
    • Calculation of the replacement correction factors for ion chambers in megavoltage beams by Monte Carlo simulation
    • DOI 10.1118/1.2898139
    • L. L. W. Wang and D. W. O. Rogers, Calculation of the replacement correction factors for ion chambers in megavoltage beams by Monte Carlo simulation., Med. Phys. 35, 1747-1755 (2008). 10.1118/1.2898139 (Pubitemid 351614788)
    • (2008) Medical Physics , vol.35 , Issue.5 , pp. 1747-1755
    • Wang, L.L.W.1    Rogers, D.W.O.2
  • 31
    • 36649023682 scopus 로고    scopus 로고
    • An experimental and computational investigation of the standard temperature-pressure correction factor for ion chambers in kilovoltage x rays
    • DOI 10.1118/1.2799580
    • D. J. La Russa, M. McEwen, and D. W. O. Rogers, An experimental and computational investigation of the standard temperature-pressure correction factor for ion chambers in kilovoltage x rays., Med. Phys. 34, 4690-4699 (2007). 10.1118/1.2799580 (Pubitemid 350197707)
    • (2007) Medical Physics , vol.34 , Issue.12 , pp. 4690-4699
    • La Russa, D.J.1    McEwen, M.2    Rogers, D.W.O.3
  • 32
    • 0016542557 scopus 로고
    • Analytic and graphical methods for assigning errors to parameters in non-linear least squares fitting
    • 10.1016/0029-554X(75)90496-6
    • D. W. O. Rogers, Analytic and graphical methods for assigning errors to parameters in non-linear least squares fitting., Nucl. Instrum. Methods 127, 253-260 (1975). 10.1016/0029-554X(75)90496-6
    • (1975) Nucl. Instrum. Methods , vol.127 , pp. 253-260
    • Rogers, D.W.O.1
  • 35
    • 0021849353 scopus 로고
    • Energy and angular distributions of photons from medical linear accelerators
    • DOI 10.1118/1.595680
    • R. Mohan, C. Chui, and L. Lidofsky, Energy and angular distributions of photons from medical linear accelerators., Med. Phys. 12, 592-597 (1985). 10.1118/1.595680 (Pubitemid 15248414)
    • (1985) Medical Physics , vol.12 , Issue.5 , pp. 592-597
    • Mohan, R.1    Chui, C.2    Lidofsky, L.3
  • 36
    • 34249023467 scopus 로고    scopus 로고
    • Direct calibration of ionization chambers in linac photon beams
    • 10.1118/1.1998523
    • M. R. McEwen and C. K. Ross, Direct calibration of ionization chambers in linac photon beams., Med. Phys. 32, 2128 (2005). 10.1118/1.1998523
    • (2005) Med. Phys. , vol.32 , pp. 2128
    • McEwen, M.R.1    Ross, C.K.2
  • 37
    • 79551679033 scopus 로고    scopus 로고
    • The central electrode correction factor for high-Z electrodes in small ionization chambers
    • 10.1118/1.3532818
    • B. R. Muir and D. W. O. Rogers, The central electrode correction factor for high-Z electrodes in small ionization chambers., Med. Phys. 38, 1081-1088 (2011). 10.1118/1.3532818
    • (2011) Med. Phys. , vol.38 , pp. 1081-1088
    • Muir, B.R.1    Rogers, D.W.O.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.