메뉴 건너뛰기




Volumn 23, Issue 2, 2007, Pages 58-66

A new method for output factor determination in MLC shaped narrow beams

Author keywords

Large area chamber; Narrow beam dosimetry; Output factor; Small fields

Indexed keywords

DIAMOND;

EID: 34347212158     PISSN: 11201797     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejmp.2007.03.002     Document Type: Article
Times cited : (66)

References (19)
  • 1
    • 0003680967 scopus 로고    scopus 로고
    • Absorbed dose determination in external beam radiotherapy: an International Code of Practice for dosimetry based on standards of absorbed dose to water
    • International Atomic Energy Agency, Vienna
    • Andreo P., Burns D.T., Hohlfeld K., Huq M.S., Kanai T., Laitano F., et al. Absorbed dose determination in external beam radiotherapy: an International Code of Practice for dosimetry based on standards of absorbed dose to water. IAEA technical report series no. 398 (2000), International Atomic Energy Agency, Vienna
    • (2000) IAEA technical report series no. 398
    • Andreo, P.1    Burns, D.T.2    Hohlfeld, K.3    Huq, M.S.4    Kanai, T.5    Laitano, F.6
  • 2
    • 0032874911 scopus 로고    scopus 로고
    • AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
    • Almond P.R., Biggs P.J., Coursey B.M., Hanson W.F., Saiful Huq M., Nath R., et al. AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med Phys 26 (1999) 1847-1870
    • (1999) Med Phys , vol.26 , pp. 1847-1870
    • Almond, P.R.1    Biggs, P.J.2    Coursey, B.M.3    Hanson, W.F.4    Saiful Huq, M.5    Nath, R.6
  • 3
    • 10744230395 scopus 로고    scopus 로고
    • Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams
    • Sánchez-Doblado F., Andreo P., Capote R., Leal A., Perucha M., Arráns R., et al. Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams. Phys Med Biol 48 (2003) 2081-2099
    • (2003) Phys Med Biol , vol.48 , pp. 2081-2099
    • Sánchez-Doblado, F.1    Andreo, P.2    Capote, R.3    Leal, A.4    Perucha, M.5    Arráns, R.6
  • 4
    • 0030026160 scopus 로고    scopus 로고
    • A comparison of dosimetry techniques in stereotactic radiosurgery
    • Heydarian M., Hoban P.W., and Beddoe A.H. A comparison of dosimetry techniques in stereotactic radiosurgery. Phys Med Biol 41 (1996) 93-110
    • (1996) Phys Med Biol , vol.41 , pp. 93-110
    • Heydarian, M.1    Hoban, P.W.2    Beddoe, A.H.3
  • 5
    • 0031956451 scopus 로고    scopus 로고
    • Use of a new type of radiochromic film, a new parallel-plate micro-chamber, MOSFETs, and TLD 800 microcubes in the dosimetry of small beams
    • Francescon P., Cora S., Cavedon C., Scalchi P., Reccanello S., and Colombo F. Use of a new type of radiochromic film, a new parallel-plate micro-chamber, MOSFETs, and TLD 800 microcubes in the dosimetry of small beams. Med Phys 25 (1998) 503-511
    • (1998) Med Phys , vol.25 , pp. 503-511
    • Francescon, P.1    Cora, S.2    Cavedon, C.3    Scalchi, P.4    Reccanello, S.5    Colombo, F.6
  • 6
    • 0032829872 scopus 로고    scopus 로고
    • Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition
    • McKerracher C., and Thwaites D.I. Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition. Phys Med Biol 44 (1999) 2143-2160
    • (1999) Phys Med Biol , vol.44 , pp. 2143-2160
    • McKerracher, C.1    Thwaites, D.I.2
  • 7
    • 0034065594 scopus 로고    scopus 로고
    • Comparative dosimetry in narrow high-energy photon beams
    • Westermark M., Arndt J., Nilsson B., and Brahme A. Comparative dosimetry in narrow high-energy photon beams. Phys Med Biol 45 (2000) 685-702
    • (2000) Phys Med Biol , vol.45 , pp. 685-702
    • Westermark, M.1    Arndt, J.2    Nilsson, B.3    Brahme, A.4
  • 8
    • 0037323117 scopus 로고    scopus 로고
    • Physical aspects of dynamic stereotactic radiosurgery with very small photon beams (1.5 and 3 mm in diameter)
    • Paskalev K.A., Seuntjens J.P., Patrocinio H.J., and Podgorsak E.B. Physical aspects of dynamic stereotactic radiosurgery with very small photon beams (1.5 and 3 mm in diameter). Med Phys 30 (2003) 111-118
    • (2003) Med Phys , vol.30 , pp. 111-118
    • Paskalev, K.A.1    Seuntjens, J.P.2    Patrocinio, H.J.3    Podgorsak, E.B.4
  • 9
    • 0037339773 scopus 로고    scopus 로고
    • The volume effect of detectors in the dosimetry of small fields used in IMRT
    • Laub W.U., and Wong T. The volume effect of detectors in the dosimetry of small fields used in IMRT. Med Phys 30 (2003) 341-347
    • (2003) Med Phys , vol.30 , pp. 341-347
    • Laub, W.U.1    Wong, T.2
  • 10
    • 0037035943 scopus 로고    scopus 로고
    • Investigation of photon beam output factors for conformal radiation therapy-Monte Carlo simulations and measurements
    • Haryanto F., Fippel M., Laub W., Dohm O., and Nüsslin F. Investigation of photon beam output factors for conformal radiation therapy-Monte Carlo simulations and measurements. Phys Med Biol 47 (2002) N133-N143
    • (2002) Phys Med Biol , vol.47
    • Haryanto, F.1    Fippel, M.2    Laub, W.3    Dohm, O.4    Nüsslin, F.5
  • 11
    • 0032860849 scopus 로고    scopus 로고
    • Dose measurements compared with Monte Carlo simulations of narrow 6 MV multileaf collimator shaped photon beams
    • De Vlamynck K., Palmans H., Verhaegen F., De Wagter C., De Neve W., and Thierens H. Dose measurements compared with Monte Carlo simulations of narrow 6 MV multileaf collimator shaped photon beams. Med Phys 26 (1999) 1874-1882
    • (1999) Med Phys , vol.26 , pp. 1874-1882
    • De Vlamynck, K.1    Palmans, H.2    Verhaegen, F.3    De Wagter, C.4    De Neve, W.5    Thierens, H.6
  • 12
    • 4644300643 scopus 로고    scopus 로고
    • An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets
    • Capote R., Sánchez-Doblado F., Leal A., Lagares J.I., and Arráns R. An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets. Med Phys 31 (2004) 2416-2422
    • (2004) Med Phys , vol.31 , pp. 2416-2422
    • Capote, R.1    Sánchez-Doblado, F.2    Leal, A.3    Lagares, J.I.4    Arráns, R.5
  • 13
    • 16444377303 scopus 로고    scopus 로고
    • Micro ionization chamber dosimetry in IMRT verification: clinical implications of dosimetric errors in the PTV
    • Sánchez-Doblado F., Capote R., Leal A., Roselló J.V., Lagares J.I., Arráns R., et al. Micro ionization chamber dosimetry in IMRT verification: clinical implications of dosimetric errors in the PTV. Radiother Oncol 75 (2005) 342-348
    • (2005) Radiother Oncol , vol.75 , pp. 342-348
    • Sánchez-Doblado, F.1    Capote, R.2    Leal, A.3    Roselló, J.V.4    Lagares, J.I.5    Arráns, R.6
  • 14
    • 16444362815 scopus 로고    scopus 로고
    • Microionization chamber for reference dosimetry in IMRT verification: clinical implications on OAR dosimetric errors
    • Sánchez-Doblado F., Capote R., Leal A., Roselló J.V., Lagares J.I., Arráns R., et al. Microionization chamber for reference dosimetry in IMRT verification: clinical implications on OAR dosimetric errors. Phys Med Biol 50 (2005) 959-970
    • (2005) Phys Med Biol , vol.50 , pp. 959-970
    • Sánchez-Doblado, F.1    Capote, R.2    Leal, A.3    Roselló, J.V.4    Lagares, J.I.5    Arráns, R.6
  • 16
    • 33144484376 scopus 로고    scopus 로고
    • The dose-area product, a new parameter for the dosimetry of narrow photon beams
    • Djouguela A., Harder D., Kollhoff R., Ruhmann A., Willborn K.C., and Poppe B. The dose-area product, a new parameter for the dosimetry of narrow photon beams. Z Med Phys 16 3 (2006) 217-227
    • (2006) Z Med Phys , vol.16 , Issue.3 , pp. 217-227
    • Djouguela, A.1    Harder, D.2    Kollhoff, R.3    Ruhmann, A.4    Willborn, K.C.5    Poppe, B.6
  • 17
    • 33847640090 scopus 로고    scopus 로고
    • Automatic determination of primary electron beam parameters in Monte Carlo simulation
    • Pena J., González-Castaño D., Gómez F., Sánchez-Doblado F., and Hartmann G.H. Automatic determination of primary electron beam parameters in Monte Carlo simulation. Med Phys 34 3 (2007) 1076-1084
    • (2007) Med Phys , vol.34 , Issue.3 , pp. 1076-1084
    • Pena, J.1    González-Castaño, D.2    Gómez, F.3    Sánchez-Doblado, F.4    Hartmann, G.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.