Volumn 34, Issue 2, 2007, Pages 485-488

Estimation of the focal spot size and shape for a medical linear accelerator by Monte Carlo simulation

Author keywords

Dose profile; Focal spot; Monte Carlo simulation; Penumbra

Indexed keywords

LINEAR ACCELERATORS;

EID: 33846615836     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2426407     Document Type: Article
Times cited : (49)

References (24)
  • 1
    • 0242521407 scopus 로고    scopus 로고
    • Monte Carlo modelling of external radiotherapy photon beams
    • F. Verhaegen and J. Seuntjens, " Monte Carlo modelling of external radiotherapy photon beams., " Phys. Med. Biol. 48, R107-R164 (2003).
    • (2003) Phys. Med. Biol. , vol.48
    • Verhaegen, F.1    Seuntjens, J.2
  • 5
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    • I. Kawrakow, " Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version., " Med. Phys. 27, 485-498 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 485-498
    • Kawrakow, I.1
  • 8
    • 0023678565 scopus 로고
    • Therapy imaging: Source sizes of radiotherapy beams
    • P. Munro, J. Rawlinson, and A. Fenster, " Therapy imaging: Source sizes of radiotherapy beams., " Med. Phys. 15, 517 (1988).
    • (1988) Med. Phys. , vol.15 , pp. 517
    • Munro, P.1    Rawlinson, J.2    Fenster, A.3
  • 9
    • 0027752810 scopus 로고
    • X-ray sources of medical linear accelerators: Focal and extra-focal radiation
    • D. A. Jaffray, J. J. Battista, A. Fenster, and P. Munro, " X-ray sources of medical linear accelerators: Focal and extra-focal radiation., " Med. Phys. 20, 1417-1427 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1417-1427
    • Jaffray, D.A.1    Battista, J.J.2    Fenster, A.3    Munro, P.4
  • 10
    • 1642454600 scopus 로고    scopus 로고
    • Comparison of beam characteristics of a gold x-ray target and a tungsten replacement target
    • B. Faddegon, B. Egley, and T. Steinberg, " Comparison of beam characteristics of a gold x-ray target and a tungsten replacement target., " Med. Phys. 31, 1 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 1
    • Faddegon, B.1    Egley, B.2    Steinberg, T.3
  • 12
    • 0032965072 scopus 로고    scopus 로고
    • Performance and beam characteristics of the Siemens Primus linear accelerator
    • M. Sontag and T. Steinberg, " Performance and beam characteristics of the Siemens Primus linear accelerator., " Med. Phys. 26, 734 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 734
    • Sontag, M.1    Steinberg, T.2
  • 13
    • 0036130664 scopus 로고    scopus 로고
    • Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam parameters
    • D. Sheikh-Bagheri and D. W. O. Rogers, " Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam parameters., " Med. Phys. 29, 379-390 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 379-390
    • Sheikh-Bagheri, D.1    Rogers, D.W.O.2
  • 15
    • 0034772905 scopus 로고    scopus 로고
    • Monte Carlo simulation of a clinical linear accelerator
    • S.-Y. Lin, T.-C. Chu, and J.-M. Lin, " Monte Carlo simulation of a clinical linear accelerator., " Appl. Radiat. Isot. 55, 759-765 (2001).
    • (2001) Appl. Radiat. Isot. , vol.55 , pp. 759-765
    • Lin, S.-Y.1    Chu, T.-C.2    Lin, J.-M.3
  • 16
    • 0037035317 scopus 로고    scopus 로고
    • Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: Results of Monte Carlo simulations for a Varian 2100EX accelerator
    • G. X. Ding, " Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: Results of Monte Carlo simulations for a Varian 2100EX accelerator., " Phys. Med. Biol. 47, 1025-1046 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 1025-1046
    • Ding, G.X.1
  • 18
    • 33744828302 scopus 로고    scopus 로고
    • On the effective point of measurement in megavoltage photon beams
    • I. Kawrakaw, " On the effective point of measurement in megavoltage photon beams., " Med. Phys. 33, 1829-1839 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 1829-1839
    • Kawrakaw, I.1
  • 20
    • 0026729304 scopus 로고
    • Measurement of the source size of a 6- and 18 MeV radiotherapy linac
    • E. Loewenthal, E. Loewinger, E. Bar-Avraham, and G. Barnea, " Measurement of the source size of a 6- and 18 MeV radiotherapy linac., " Med. Phys. 19, 687-690 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 687-690
    • Loewenthal, E.1    Loewinger, E.2    Bar-Avraham, E.3    Barnea, G.4
  • 21
    • 0029003090 scopus 로고
    • X-ray source and the output factor
    • T. Zhu, B. Bjarngard, and H. Shackford, " x-ray source and the output factor., " Med. Phys. 22, 793 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 793
    • Zhu, T.1    Bjarngard, B.2    Shackford, H.3
  • 22
    • 0042476386 scopus 로고    scopus 로고
    • Geometrical and dosimetrical characterization of the photon source using a micro-multileaf collimator for stereotactic radiosurgery
    • H. Treuer, M. Hoevels, K. Luyken, S. Hunsche, M. Kocher, R. Muller, and V. Sturm, " Geometrical and dosimetrical characterization of the photon source using a micro-multileaf collimator for stereotactic radiosurgery., " Phys. Med. Biol. 48, 2307-2319 (2003).
    • (2003) Phys. Med. Biol. , vol.48 , pp. 2307-2319
    • Treuer, H.1    Hoevels, M.2    Luyken, K.3    Hunsche, S.4    Kocher, M.5    Muller, R.6    Sturm, V.7
  • 23
    • 0027733647 scopus 로고
    • The source-density function: Determination from measured lateral dose distributions and use for convolution dosimetry
    • H. Treuer, R. Boesecke, W. Schlegel, G. Hartmann, R. Muller, and V. Sturm, " The source-density function: Determination from measured lateral dose distributions and use for convolution dosimetry., " Phys. Med. Biol. 38, 1895-1909 (1993).
    • (1993) Phys. Med. Biol. , vol.38 , pp. 1895-1909
    • Treuer, H.1    Boesecke, R.2    Schlegel, W.3    Hartmann, G.4    Muller, R.5    Sturm, V.6
  • 24
    • 85027235368 scopus 로고
    • SLAC-265," Stanford Linear Accelerator Center, Stanford, California
    • W. R. Nelson, H. Hirayama, and D. W. O. Rogers, "The EGS4 Code System, Report No. SLAC-265, " Stanford Linear Accelerator Center, Stanford, California (1985).
    • (1985)
    • Nelson, W.R.1    Hirayama, H.2    Rogers, D.W.O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.