A planar PDMS micropump using in-contact minimized-leakage check valves

Author keywords

[No Author keywords available]

Indexed keywords

ACCURATE ANALYSIS; BACK PRESSURES; CHECK VALVES; DEVICE GEOMETRIES; DIVERSE APPLICATIONS; EXPERIMENTAL CHARACTERIZATION; IN-PLANE; LAB-ON-A-CHIP SYSTEMS; LEAKAGE FLOW; LUMPED-PARAMETER; MAXIMUM FLOW RATE; MICRO PUMP; OPERATING PARAMETERS; POLYDIMETHYLSILOXANE PDMS; PUMP CHAMBERS; SIMPLE STRUCTURES; SINGLE LAYER; SYSTEM INTEGRATION; THEORETICAL MODELS; THIN MEMBRANE;

EID: 77957853309     PISSN: 09601317     EISSN: 13616439     Source Type: Journal    
DOI: 10.1088/0960-1317/20/9/095033     Document Type: Article
Times cited : (34)

References (32)
  • 1
    • 13844265135 scopus 로고    scopus 로고
    • Lab-on-a-chip systems for biomedical and environmental monitoring
    • Gardeniers J G E and van den Berg A 2004 Lab-on-a-chip systems for biomedical and environmental monitoring Anal. Bioanal. Chem. 378 1700-3
    • (2004) Anal. Bioanal. Chem. , vol.378 , pp. 1700-1703
    • Gardeniers, J.G.E.1    Van Den Berg, A.2
  • 3
    • 33747117373 scopus 로고    scopus 로고
    • The origins and the future of microfluidics
    • Whitesides G M 2006 The origins and the future of microfluidics Nature 442 368-73
    • (2006) Nature , vol.442 , pp. 368-373
    • Whitesides, G.M.1
  • 4
    • 0033882554 scopus 로고    scopus 로고
    • Theoretical and experimental study of MHD (magnetohydrodynamic) micropump
    • Jang J and Lee S S 2000 Theoretical and experimental study of MHD (magnetohydrodynamic) micropump Sensors Actuators A 80 84-9
    • (2000) Sensors Actuators A , vol.80 , pp. 84-89
    • Jang, J.1    Lee, S.S.2
  • 5
    • 29244460036 scopus 로고    scopus 로고
    • A new electro-osmotic pump based on silica monoliths
    • Wang P, Chen Z and Chang H-C 2006 A new electro-osmotic pump based on silica monoliths Sensors Actuators B 113 500-9
    • (2006) Sensors Actuators B , vol.113 , pp. 500-509
    • Wang, P.1    Chen, Z.2    Chang, H.-C.3
  • 12
    • 0141907969 scopus 로고    scopus 로고
    • A plastic micropump constructed with conventional techniques and materials
    • Bohm S, Olthuis W and Bergveld P 1999 A plastic micropump constructed with conventional techniques and materials Sensors Actuators A 77 223-8
    • (1999) Sensors Actuators A , vol.77 , pp. 223-228
    • Bohm, S.1    Olthuis, W.2    Bergveld, P.3
  • 13
    • 18844370104 scopus 로고    scopus 로고
    • Piezoelectrically actuated dome-shaped diaphragm micropump
    • Feng G-H and Kim E S 2005 Piezoelectrically actuated dome-shaped diaphragm micropump J. Microelectromech. Syst. 14 192-9
    • (2005) J. Microelectromech. Syst. , vol.14 , pp. 192-199
    • Feng, G.-H.1    Kim, E.S.2
  • 15
  • 16
    • 34548214658 scopus 로고    scopus 로고
    • A novel electromagnetic elastomer membrane actuator with a semi-embedded coil
    • Yin H-L, Huang Y-C, Fang W and Hsieh J 2007 A novel electromagnetic elastomer membrane actuator with a semi-embedded coil Sensors Actuators A 139 194-202
    • (2007) Sensors Actuators A , vol.139 , pp. 194-202
    • Yin, H.-L.1    Huang, Y.-C.2    Fang, W.3    Hsieh, J.4
  • 17
    • 55349131660 scopus 로고    scopus 로고
    • Performance characteristics of a polypyrrole modified polydimethylsiloxane (PDMS) membrane based microfluidic pump
    • Kim J H, Lau K T, Shepherd R, Wu Y, Wallace G and Diamond D 2008 Performance characteristics of a polypyrrole modified polydimethylsiloxane (PDMS) membrane based microfluidic pump Sensors Actuators A 148 239-44
    • (2008) Sensors Actuators A , vol.148 , pp. 239-244
    • Kim, J.H.1    Lau, K.T.2    Shepherd, R.3    Wu, Y.4    Wallace, G.5    Diamond, D.6
  • 18
    • 0346341044 scopus 로고    scopus 로고
    • A disposable polydimethylsiloxane-based diffuser micropump actuated by piezoelectric-disc
    • Kim J-H, Kang C J and Kim Y-S 2004 A disposable polydimethylsiloxane- based diffuser micropump actuated by piezoelectric-disc Microelectron. Eng. 71 119-224
    • (2004) Microelectron. Eng. , vol.71 , pp. 119-224
    • Kim, J.-H.1    Kang, C.J.2    Kim, Y.-S.3
  • 19
    • 17644400484 scopus 로고    scopus 로고
    • A disposable thermopneumatic-actuated micropump stacked with PDMS layers and ITO-coated glass
    • Kim J-H, Na K-H, Kang C J and Kim Y-S 2005 A disposable thermopneumatic-actuated micropump stacked with PDMS layers and ITO-coated glass Sensors Actuators A 120 365-9
    • (2005) Sensors Actuators A , vol.120 , pp. 365-369
    • Kim, J.-H.1    Na, K.-H.2    Kang, C.J.3    Kim, Y.-S.4
  • 20
    • 34548180433 scopus 로고    scopus 로고
    • A novel polydimethylsiloxane microfluidic system including thermopneumatic-actuated micropump and paraffin-actuated microvalve
    • Yoo J-C, Choi Y J, Kang C J and Kim Y-S 2007 A novel polydimethylsiloxane microfluidic system including thermopneumatic-actuated micropump and paraffin-actuated microvalve Sensors Actuators A 139 216-20
    • (2007) Sensors Actuators A , vol.139 , pp. 216-220
    • Yoo, J.-C.1    Choi, Y.J.2    Kang, C.J.3    Kim, Y.-S.4
  • 21
    • 13244251242 scopus 로고    scopus 로고
    • Micropumps-past, progress and future prospects
    • Woias P 2005 Micropumps-past, progress and future prospects Sensors Actuators B 105 28-38
    • (2005) Sensors Actuators B , vol.105 , pp. 28-38
    • Woias, P.1
  • 24
    • 33746519902 scopus 로고    scopus 로고
    • Photopolymerized check valve and its integration into a pneumatic pumping system for biocompatible sample delivery
    • Kim J, Baek J, Lee K, Park Y, Sun K, Lee T and Lee S 2006 Photopolymerized check valve and its integration into a pneumatic pumping system for biocompatible sample delivery Lab Chip 6 1091-4
    • (2006) Lab Chip , vol.6 , pp. 1091-1094
    • Kim, J.1    Baek, J.2    Lee, K.3    Park, Y.4    Sun, K.5    Lee, T.6    Lee, S.7
  • 25
    • 33847296185 scopus 로고    scopus 로고
    • Planar micro-check valves exploiting large polymer compliance
    • Yang B and Lin Q 2007 Planar micro-check valves exploiting large polymer compliance Sensors Actuators A 134 186-93
    • (2007) Sensors Actuators A , vol.134 , pp. 186-193
    • Yang, B.1    Lin, Q.2
  • 29
    • 7944231725 scopus 로고    scopus 로고
    • Surface micromachined electrostatically actuated micro peristaltic pump
    • Xie J, Shih J, Lin Q, Yang B and Tai Y-C 2004 Surface micromachined electrostatically actuated micro peristaltic pump Lab Chip 4 495-501
    • (2004) Lab Chip , vol.4 , pp. 495-501
    • Xie, J.1    Shih, J.2    Lin, Q.3    Yang, B.4    Tai, Y.-C.5
  • 30
    • 44149100777 scopus 로고    scopus 로고
    • Optimization of poly-di-methyl-siloxane (PDMS) substrates for studying cellular adhesion and motility
    • Fuard D, Tzvetkova-Chevolleau T, Decossas S, Tracqui P and Schiavone P 2008 Optimization of poly-di-methyl-siloxane (PDMS) substrates for studying cellular adhesion and motility Microelectron. Eng. 85 1289-93
    • (2008) Microelectron. Eng. , vol.85 , pp. 1289-1293
    • Fuard, D.1    Tzvetkova-Chevolleau, T.2    Decossas, S.3    Tracqui, P.4    Schiavone, P.5
  • 31
    • 77957839224 scopus 로고    scopus 로고
    • A disposable self-priming and bubble tolerance pneumatic actuation micro-pump
    • Xu G, Ting D N, Luar V and Saw L K 2003 A disposable self-priming and bubble tolerance pneumatic actuation micro-pump Int. J. Comput. Eng. Sci. 4 253-6
    • (2003) Int. J. Comput. Eng. Sci. , vol.4 , pp. 253-256
    • Xu, G.1    Ting, D.N.2    Luar, V.3    Saw, L.K.4
  • 32
    • 31444437947 scopus 로고    scopus 로고
    • Pneumatically driven peristaltic micropumps utilizing serpentine-shape channels
    • Wang C-H and Lee G-B 2006 Pneumatically driven peristaltic micropumps utilizing serpentine-shape channels J. Micromech. Microeng. 16 341-8
    • (2006) J. Micromech. Microeng. , vol.16 , pp. 341-348
    • Wang, C.-H.1    Lee, G.-B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.