메뉴 건너뛰기




Volumn , Issue , 2010, Pages

Energy and thermal aware buffer cache replacement algorithm

Author keywords

Buffer cache; Data servers; Memory energy

Indexed keywords

GREEN COMPUTING; THERMAL MANAGEMENT (ELECTRONICS);

EID: 77957848595     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MSST.2010.5496982     Document Type: Conference Paper
Times cited : (3)

References (36)
  • 8
    • 34047164484 scopus 로고    scopus 로고
    • Pabc: Power-aware buffer cache management for low power consumption
    • M. Lee, E. Seo, J. Lee, , and J. Kim, "Pabc: Power-aware buffer cache management for low power consumption," IEEE Transactions on Computers, vol. 56, no. 4, 2007.
    • (2007) IEEE Transactions on Computers , vol.56 , Issue.4
    • Lee, M.1    Seo, E.2    Lee, J.3    Kim, J.4
  • 9
    • 55849084210 scopus 로고    scopus 로고
    • Performance-directed energy management using bos
    • P. Ramamurthy and R. Palaniappan, "Performance-directed energy management using bos," SIGOPS Oper. Syst. Rev., vol. 41, no. 1, pp. 66-77, 2007.
    • (2007) SIGOPS Oper. Syst. Rev. , vol.41 , Issue.1 , pp. 66-77
    • Ramamurthy, P.1    Palaniappan, R.2
  • 10
    • 0036059441 scopus 로고    scopus 로고
    • Automatic data migration for reducing energy consumption in multi-bank memory systems
    • New York, NY, USA: ACM Press
    • V. D. L. Luz, M. Kandemir, and I. Kolcu, "Automatic data migration for reducing energy consumption in multi-bank memory systems," in DAC '02: Proceedings of the 39th conference on Design automation. New York, NY, USA: ACM Press, 2002, pp. 213-218.
    • (2002) DAC '02: Proceedings of the 39th Conference on Design Automation , pp. 213-218
    • Luz, V.D.L.1    Kandemir, M.2    Kolcu, I.3
  • 14
    • 85013771039 scopus 로고    scopus 로고
    • Performance directed energy management for main memory and disks
    • X. Li, Z. Li, Y. Zhou, and S. Adve, "Performance directed energy management for main memory and disks," ACM Trans. Storage, vol. 1, no. 3, pp. 346-380, 2005.
    • (2005) ACM Trans. Storage , vol.1 , Issue.3 , pp. 346-380
    • Li, X.1    Li, Z.2    Zhou, Y.3    Adve, S.4
  • 16
    • 54249105794 scopus 로고    scopus 로고
    • An energy-oriented evaluation of buffer cache algorithms using parallel i/o workloads
    • J. Yue, Y. Z. Zhu, and Z. Cai, "An energy-oriented evaluation of buffer cache algorithms using parallel i/o workloads," IEEE Trans. Parallel Distrib. Syst., vol. 19, no. 11, pp. 1565-1578, 2008.
    • (2008) IEEE Trans. Parallel Distrib. Syst. , vol.19 , Issue.11 , pp. 1565-1578
    • Yue, J.1    Zhu, Y.Z.2    Cai, Z.3
  • 21
    • 35348841360 scopus 로고    scopus 로고
    • Bensley fb-dimm performance/thermal management
    • Tech. Rep.
    • K. Man, "Bensley fb-dimm performance/thermal management," Intel Developer Forum, Tech. Rep., 2006.
    • (2006) Intel Developer Forum
    • Man, K.1
  • 25
    • 85077587370 scopus 로고    scopus 로고
    • Design and implementation of power-aware virtual memory
    • [Online]. Available
    • H. Huang, P. Pillai, and K. G. Shin, "Design and implementation of power-aware virtual memory," in USENIX Annual Technical Conference, 2003, pp. 57-70. [Online]. Available: citeseer.ist.psu.edu/article/huang03design.html
    • USENIX Annual Technical Conference, 2003 , pp. 57-70
    • Huang, H.1    Pillai, P.2    Shin, K.G.3
  • 26
    • 77955076011 scopus 로고    scopus 로고
    • Memory miser: Improving main memory energy efficiency in servers
    • M. E. Tolentino, J. Turner, and K. W. Cameron, "Memory miser: Improving main memory energy efficiency in servers," IEEE Trans. Comput., vol. 58, no. 3, pp. 336-350, 2009.
    • (2009) IEEE Trans. Comput. , vol.58 , Issue.3 , pp. 336-350
    • Tolentino, M.E.1    Turner, J.2    Cameron, K.W.3
  • 31
    • 36949005837 scopus 로고    scopus 로고
    • Dram-level prefetching for fully-buffered dimm: Design, performance and power saving
    • n. Z. Z. n. Z. Z. H. D. null IEEE Computer Society, address = Washington, DC, USA
    • n. Z. Z. n. Z. Z. H. D. Jiang Lin, null Hongzhong Zheng, "Dram-level prefetching for fully-buffered dimm: Design, performance and power saving," in ispass '07: 2007 IEEE International Symposium on Performance Analysis of Systems & Software. IEEE Computer Society, address = Washington, DC, USA,, 2007.
    • (2007) ispass '07: 2007 IEEE International Symposium on Performance Analysis of Systems & Software
    • Lin, J.1    Zheng, H.2
  • 36
    • 67649397389 scopus 로고    scopus 로고
    • An adaptive interleaving technique for memory performance-per-watt management
    • B
    • H. S. Khargharia, B. and M. S. Yousif, "An adaptive interleaving technique for memory performance-per-watt management." IEEE Trans. Parallel Distrib. Syst., vol. 20, no. 7, pp. 1011-1022, 2009.
    • (2009) IEEE Trans. Parallel Distrib. Syst. , vol.20 , Issue.7 , pp. 1011-1022
    • Khargharia, H.S.1    Yousif, M.S.2