메뉴 건너뛰기




Volumn 25, Issue 2, 2010, Pages 385-393

Retrospective analysis of bar-retained dentures with cantilever extension: Marginal bone level changes around dental implants over time

Author keywords

Biologic width; Cantilever length; Crestal bone loss; Dental implants; Implant retained overdenture

Indexed keywords

ADULT; AGED; ALVEOLAR BONE LOSS; ARTICLE; CLASSIFICATION; DENTURE; EDENTULOUSNESS; FEMALE; FOLLOW UP; HUMAN; INSTRUMENTATION; JAW; MALE; MANDIBLE; MAXILLA; MIDDLE AGED; PANORAMIC RADIOGRAPHY; RADIOGRAPHY; RETROSPECTIVE STUDY; SURFACE PROPERTY; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 77953280155     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (49)

References (55)
  • 1
  • 3
    • 0036369561 scopus 로고    scopus 로고
    • A review of clinical and technical considerations for fixed and removable implant prostheses in the edentulous mandible
    • Zitzmann NU, Marinello CP. A review of clinical and technical considerations for fixed and removable implant prostheses in the edentulous mandible. Int J Prosthodont 2002;15: 65-72.
    • (2002) Int J Prosthodont , vol.15 , pp. 65-72
    • Zitzmann, N.U.1    Marinello, C.P.2
  • 4
    • 0038305565 scopus 로고    scopus 로고
    • The anterior cantilever in the implant-supported screw-retained mandibular prosthesis
    • Brosky ME, Korioth TW, Hodges J. The anterior cantilever in the implant-supported screw-retained mandibular prosthesis. J Prosthet Dent 2003;89: 244-249.
    • (2003) J Prosthet Dent , vol.89 , pp. 244-249
    • Brosky, M.E.1    Korioth, T.W.2    Hodges, J.3
  • 5
    • 0030141120 scopus 로고    scopus 로고
    • Determination of cantilever length-anterior-posterior spread ratio assuming failure criteria to be the compromise of the prosthesis retaining screw-prosthesis joint
    • McAlarney ME, Stavropoulos DN. Determination of cantilever length-anterior-posterior spread ratio assuming failure criteria to be the compromise of the prosthesis retaining screw-prosthesis joint. Int J Oral Maxillofac Implants 1996;11: 331-339.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 331-339
    • McAlarney, M.E.1    Stavropoulos, D.N.2
  • 6
    • 0030208125 scopus 로고    scopus 로고
    • Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis
    • Sertgöz A, Güvener S. Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis. J Prosthet Dent 1996;76: 165-169.
    • (1996) J Prosthet Dent , vol.76 , pp. 165-169
    • Sertgöz, A.1    Güvener, S.2
  • 7
    • 0038158252 scopus 로고    scopus 로고
    • Finite element analysis of the stresses around fixtures in various reconstructed mandibular models-Part II (effect of horizontal load)
    • Nagasao T, Kobayashi M, Tsuchiya Y, Kaneko T, Nakajima T. Finite element analysis of the stresses around fixtures in various reconstructed mandibular models-Part II (effect of horizontal load). J Craniomaxillofac Surg 2003;31: 168-175.
    • (2003) J Craniomaxillofac Surg , vol.31 , pp. 168-175
    • Nagasao, T.1    Kobayashi, M.2    Tsuchiya, Y.3    Kaneko, T.4    Nakajima, T.5
  • 8
    • 1242317770 scopus 로고    scopus 로고
    • The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite element study
    • Eskitascioglu G, Usumez A, Sevimay M, Soykan E, Unsal E. The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite element study. J Prosthet Dent 2004;91: 144-150.
    • (2004) J Prosthet Dent , vol.91 , pp. 144-150
    • Eskitascioglu, G.1    Usumez, A.2    Sevimay, M.3    Soykan, E.4    Unsal, E.5
  • 9
    • 0032276922 scopus 로고    scopus 로고
    • Influence of percentage of osseointegration on stress distribution around dental implants
    • Lai H, Zhang F, Zhang B, Yang C, Xue M. Influence of percentage of osseointegration on stress distribution around dental implants. Chin J Dent Res 1998;1: 7-11.
    • (1998) Chin J Dent Res , vol.1 , pp. 7-11
    • Lai, H.1    Zhang, F.2    Zhang, B.3    Yang, C.4    Xue, M.5
  • 10
    • 0026892027 scopus 로고
    • Stress distribution around dental implants: Influence of superstructure, length of im - plants, and height of mandible
    • Meijer HJ, Kuiper JH, Starmans FJ, Bosman F. Stress distribution around dental implants: Influence of superstructure, length of im - plants, and height of mandible. J Prosthet Dent 1992;68: 96-102.
    • (1992) J Prosthet Dent , vol.68 , pp. 96-102
    • Meijer, H.J.1    Kuiper, J.H.2    Starmans, F.J.3    Bosman, F.4
  • 11
    • 0032135072 scopus 로고    scopus 로고
    • Measurements of bone and frame-work deformations induced by misfit of implant superstructures
    • Jemt T, Lekholm U. Measurements of bone and frame-work deformations induced by misfit of implant superstructures. A pilot study in rabbits. Clin Oral Implants Res 1998;9: 272-280.
    • (1998) A pilot study in rabbits. Clin Oral Implants Res , vol.9 , pp. 272-280
    • Jemt, T.1    Lekholm, U.2
  • 12
    • 0030226140 scopus 로고    scopus 로고
    • Comparison of strains transferred to a bone simulant between as-cast and postsoldered implant frameworks for a five-implant-supported fixed prosthesis
    • Clelland NL, Carr AB, Gilat A. Comparison of strains transferred to a bone simulant between as-cast and postsoldered implant frameworks for a five-implant-supported fixed prosthesis. J Prosthodont 1996;5: 193-200.
    • (1996) J Prosthodont , vol.5 , pp. 193-200
    • Clelland, N.L.1    Carr, A.B.2    Gilat, A.3
  • 13
    • 38049060005 scopus 로고    scopus 로고
    • Influence of fixation mode and superstructure span upon strain development of implant fixed partial dentures
    • Karl M, Wichmann MG, Winter W, Graef F, Taylor TD, Heckmann SM. Influence of fixation mode and superstructure span upon strain development of implant fixed partial dentures. J Pros - thodont 2008;17: 3-8.
    • (2008) J Pros - thodont , vol.17 , pp. 3-8
    • Karl, M.1    Wichmann, M.G.2    Winter, W.3    Graef, F.4    Taylor, T.D.5    Heckmann, S.M.6
  • 14
    • 0029185973 scopus 로고
    • The clinical significance of distortion in implant prosthodontics: Is there such a thing as passive fit?
    • Tan KB. The clinical significance of distortion in implant prosthodontics: Is there such a thing as passive fit? Ann Acad Med Singapore 1995;24: 138-157.
    • (1995) Ann Acad Med Singapore , vol.24 , pp. 138-157
    • Tan, K.B.1
  • 15
    • 18044403181 scopus 로고    scopus 로고
    • The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: An animal experimental study
    • Duyck J, Rønold HJ, Van Oosterwyck H, Naert I, Vander Sloten J, Ellingsen JE. The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: An animal experimental study. Clin Oral Implants Res 2001;12: 207-218.
    • (2001) Clin Oral Implants Res , vol.12 , pp. 207-218
    • Duyck, J.1    Rønold, H.J.2    Van Oosterwyck, H.3    Naert, I.4    Vander Sloten, J.5    Ellingsen, J.E.6
  • 16
    • 0023672133 scopus 로고
    • Bone resorption around fixtures in edentulous patients treated with mandibular fixed tissue-integrated prostheses
    • Lindquist LW, Rockler B, Carlsson GE. Bone resorption around fixtures in edentulous patients treated with mandibular fixed tissue-integrated prostheses. J Prosthet Dent 1988;59: 59-63.
    • (1988) J Prosthet Dent , vol.59 , pp. 59-63
    • Lindquist, L.W.1    Rockler, B.2    Carlsson, G.E.3
  • 19
    • 51849088954 scopus 로고    scopus 로고
    • Bone level changes at implants supporting crowns or fixed partial dentures with or without cantilevers
    • Hälg GA, Schmid J, Hämmerle CH. Bone level changes at implants supporting crowns or fixed partial dentures with or without cantilevers. Clin Oral Implants Res 2008;19: 983-990.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 983-990
    • Hälg, G.A.1    Schmid, J.2    Hämmerle, C.H.3
  • 20
    • 10444224762 scopus 로고    scopus 로고
    • Bone level change at implant-supported fixed partial dentures with and without cantilever extension after 5 years in function
    • Wennström J, Zurdo J, Karlsson S, Ekestubbe A, Gröndahl K, Lindhe J. Bone level change at implant-supported fixed partial dentures with and without cantilever extension after 5 years in function. J Clin Periodontol 2004;31: 1077-1083.
    • (2004) J Clin Periodontol , vol.31 , pp. 1077-1083
    • Wennström, J.1    Zurdo, J.2    Karlsson, S.3    Ekestubbe, A.4    Gröndahl, K.5    Lindhe, J.6
  • 21
    • 0034277057 scopus 로고    scopus 로고
    • Effect of anchorage systems and extension base contact on load transfer with mandibular implant-retained overdentures
    • Sadowsky SJ, Caputo AA. Effect of anchorage systems and extension base contact on load transfer with mandibular implant-retained overdentures. J Prosthet Dent 2000;84: 327-334.
    • (2000) J Prosthet Dent , vol.84 , pp. 327-334
    • Sadowsky, S.J.1    Caputo, A.A.2
  • 22
    • 0031107925 scopus 로고    scopus 로고
    • Force distribution on implants supporting overdentures: The effect of distal bar extension
    • Mericske-Stern R. Force distribution on implants supporting overdentures: The effect of distal bar extension. A 3-D in vivo study. Clin Oral Implants Res 1997;8: 142-151.
    • (1997) A 3-D in vivo study. Clin Oral Implants Res , vol.8 , pp. 142-151
    • Mericske-Stern, R.1
  • 23
    • 2342439421 scopus 로고    scopus 로고
    • Radiologic follow-up of peri-implant bone loss around machine-surfaced and roughsurfaced interforaminal implants in the mandible functionally loaded for 3 to 7 years
    • Zechner W, Trinkl N, Watzak G, et al. Radiologic follow-up of peri-implant bone loss around machine-surfaced and roughsurfaced interforaminal implants in the mandible functionally loaded for 3 to 7 years. Int J Oral Maxillofac Implants 2004;19: 216-221.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 216-221
    • Zechner, W.1    Trinkl, N.2    Watzak, G.3
  • 24
    • 33750693702 scopus 로고    scopus 로고
    • Radiological and clinical follow-up of machinedand anodized-surface implants after mean functional loading for 33 months
    • Watzak G, Zechner W, Busenlechner D, Arnhart C, Gruber R, Watzek G. Radiological and clinical follow-up of machinedand anodized-surface implants after mean functional loading for 33 months. Clin Oral Implants Res 2006;17: 651-657.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 651-657
    • Watzak, G.1    Zechner, W.2    Busenlechner, D.3    Arnhart, C.4    Gruber, R.5    Watzek, G.6
  • 25
    • 0348191040 scopus 로고    scopus 로고
    • Longterm stability of osseointegrated implants in augmented bone: A 5-year prospective study in partially edentulous patients
    • Buser D, Ingmarsson S, Dula K, Lussi A, Hirt HP, Belser UC. Longterm stability of osseointegrated implants in augmented bone: A 5-year prospective study in partially edentulous patients. Int J Periodontics Restorative Dent 2002;22: 109-117.
    • (2002) Int J Periodontics Restorative Dent , vol.22 , pp. 109-117
    • Buser, D.1    Ingmarsson, S.2    Dula, K.3    Lussi, A.4    Hirt, H.P.5    Belser, U.C.6
  • 26
    • 0345144292 scopus 로고
    • Methode zur quantitativen Erfassung und statistischen Auswertung des periimplantären Knochenabbaus
    • Goméz-Román G, Axmann D, D’Hoedt B, Schulte W. Methode zur quantitativen Erfassung und statistischen Auswertung des periimplantären Knochenabbaus. Stomatologie 1995;92: 463-471.
    • (1995) Stomatologie , vol.92 , pp. 463-471
    • Goméz-Román, G.1    Axmann, D.2    D’Hoedt, B.3    Schulte, W.4
  • 28
    • 0026952014 scopus 로고
    • Digital radiology for implant treatment planning and evaluation
    • Jeffcoat MK. Digital radiology for implant treatment planning and evaluation. Dentomaxillofac Radiol 1992;21: 203-207.
    • (1992) Dentomaxillofac Radiol , vol.21 , pp. 203-207
    • Jeffcoat, M.K.1
  • 29
    • 0032111331 scopus 로고    scopus 로고
    • Radiographic assessment of changes in marginal bone around endosseous implants supporting mandibular overdentures
    • Batenburg RH, Meijer HJ, Geraets WG, van der Stelt PF. Radiographic assessment of changes in marginal bone around endosseous implants supporting mandibular overdentures. Dentomaxillofac Radiol 1998;27: 221-224.
    • (1998) Dentomaxillofac Radiol , vol.27 , pp. 221-224
    • Batenburg, R.H.1    Meijer, H.J.2    Geraets, W.G.3    van der Stelt, P.F.4
  • 30
    • 0347418234 scopus 로고    scopus 로고
    • Rotational panoramic versus intraoral rectangular radiographs for evaluation of peri-implant bone loss in the anterior atrophic mandible
    • Zechner W, Watzak G, Gahleitner A, Busenlechner D, Tepper G, Watzek G. Rotational panoramic versus intraoral rectangular radiographs for evaluation of peri-implant bone loss in the anterior atrophic mandible. Int J Oral Maxillofac Implants 2003;18: 873-878.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 873-878
    • Zechner, W.1    Watzak, G.2    Gahleitner, A.3    Busenlechner, D.4    Tepper, G.5    Watzek, G.6
  • 32
    • 0035404090 scopus 로고    scopus 로고
    • Marginal bone loss around implants retaining hinging mandibular overdentures at 4-, 8- and 12-years follow-up
    • van Steenberghe D, Quirynen M, Naert I, Maffei G, Jacobs R. Marginal bone loss around implants retaining hinging mandibular overdentures at 4-, 8- and 12-years follow-up. J Clin Periodontol 2001;28: 628-633.
    • (2001) J Clin Periodontol , vol.28 , pp. 628-633
    • van Steenberghe, D.1    Quirynen, M.2    Naert, I.3    Maffei, G.4    Jacobs, R.5
  • 33
    • 84995762475 scopus 로고    scopus 로고
    • Digitales versus konventionelles Zahnfilmröntgen
    • Schmage P, Nergiz I, Pfeiffer P, Platzer U. Digitales versus konventionelles Zahnfilmröntgen. ZWR 1997;106: 504-509.
    • (1997) ZWR , vol.106 , pp. 504-509
    • Schmage, P.1    Nergiz, I.2    Pfeiffer, P.3    Platzer, U.4
  • 34
    • 2342424512 scopus 로고    scopus 로고
    • Comparative value of attachment measurements in implant dentistry
    • Deppe H, Wagenpfeil S, Donath K. Comparative value of attachment measurements in implant dentistry. Int J Oral Maxillofac Implants 2004;19: 208-215.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 208-215
    • Deppe, H.1    Wagenpfeil, S.2    Donath, K.3
  • 35
    • 84988998521 scopus 로고
    • The longterm efficacy of currently used dental implants: A review and proposed criteria of success
    • Albrektsson T, Zarb G, Worthington P, Eriksson AR. The longterm efficacy of currently used dental implants: A review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1: 11-25.
    • (1986) Int J Oral Maxillofac Implants , vol.1 , pp. 11-25
    • Albrektsson, T.1    Zarb, G.2    Worthington, P.3    Eriksson, A.R.4
  • 36
    • 0024760224 scopus 로고
    • Criteria for success of osseointegrated endosseous implants
    • Smith DE, Zarb GA. Criteria for success of osseointegrated endosseous implants. J Prosthet Dent 1989;62: 567-572.
    • (1989) J Prosthet Dent , vol.62 , pp. 567-572
    • Smith, D.E.1    Zarb, G.A.2
  • 39
    • 4344594280 scopus 로고    scopus 로고
    • Long-term treatment outcomes in edentulous patients with implant-fixed prostheses: The Toronto study
    • Attard NJ, Zarb GA. Long-term treatment outcomes in edentulous patients with implant-fixed prostheses: The Toronto study. Int J Prosthodont 2004;17: 417-424.
    • (2004) Int J Prosthodont , vol.17 , pp. 417-424
    • Attard, N.J.1    Zarb, G.A.2
  • 40
    • 9644257307 scopus 로고    scopus 로고
    • A three-year follow-up report of a comparative study of ITI dental implants and Brånemark system implants in the treatment of the partially edentulous maxilla
    • Astrand P, Engquist B, Anzén B, et al. A three-year follow-up report of a comparative study of ITI dental implants and Brånemark system implants in the treatment of the partially edentulous maxilla. Clin Implant Dent Relat Res 2004;6: 130-141.
    • (2004) Clin Implant Dent Relat Res , vol.6 , pp. 130-141
    • Astrand, P.1    Engquist, B.2    Anzén, B.3
  • 41
    • 0030278632 scopus 로고    scopus 로고
    • A 1-year radiographic evaluation of marginal bone around dental implants
    • Jung YC, Han CH, Lee KW. A 1-year radiographic evaluation of marginal bone around dental implants. Int J Oral Maxillofac Implants 1996;11: 811-818.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 811-818
    • Jung, Y.C.1    Han, C.H.2    Lee, K.W.3
  • 43
    • 42149170576 scopus 로고    scopus 로고
    • Biologic width changes around loaded implants inserted in different levels in relation to crestal bone: Histometric evaluation in canine mandible
    • Pontes AE, Ribeiro FS, Iezzi G, Piattelli A, Cirelli JA, Marcantonio E Jr. Biologic width changes around loaded implants inserted in different levels in relation to crestal bone: Histometric evaluation in canine mandible. Clin Oral Implants Res 2008;19: 483-490.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 483-490
    • Pontes, A.E.1    Ribeiro, F.S.2    Iezzi, G.3    Piattelli, A.4    Cirelli, J.A.5    Marcantonio Jr, E.6
  • 44
    • 84995807391 scopus 로고
    • Dimensions and relations of the dentogingival junction in humans
    • Gargiulo AW, Wentz FM, Orban B. Dimensions and relations of the dentogingival junction in humans. J Periodontol 1961;32: 261-267.
    • (1961) J Periodontol , vol.32 , pp. 261-267
    • Gargiulo, A.W.1    Wentz, F.M.2    Orban, B.3
  • 45
    • 0037364681 scopus 로고    scopus 로고
    • Persistent acute inflammation at the implant-abutment interface
    • Broggini N, McManus LM, Hermann JS, et al. Persistent acute inflammation at the implant-abutment interface. J Dent Res 2003;82: 232-237.
    • (2003) J Dent Res , vol.82 , pp. 232-237
    • Broggini, N.1    McManus, L.M.2    Hermann, J.S.3
  • 47
    • 38049070206 scopus 로고    scopus 로고
    • Marginal bone loss in dental implants subjected to early loading (6 to 8 weeks postplacement) with a retrospective short-term follow-up
    • Boronat A, Peñarrocha M, Carrillo C, Marti E. Marginal bone loss in dental implants subjected to early loading (6 to 8 weeks postplacement) with a retrospective short-term follow-up. J Oral Maxillofac Surg 2008;66: 246-250.
    • (2008) J Oral Maxillofac Surg , vol.66 , pp. 246-250
    • Boronat, A.1    Peñarrocha, M.2    Carrillo, C.3    Marti, E.4
  • 49
    • 0034232321 scopus 로고    scopus 로고
    • Long-term marginal periimplant bone loss in edentulous patients
    • Carlsson GE, Lindquist LW, Jemt T. Long-term marginal periimplant bone loss in edentulous patients. Int J Prosthodont 2000;13: 295-302.
    • (2000) Int J Prosthodont , vol.13 , pp. 295-302
    • Carlsson, G.E.1    Lindquist, L.W.2    Jemt, T.3
  • 50
    • 0034303173 scopus 로고    scopus 로고
    • Implant-retained cantilever fixed prosthesis:Where and when
    • Becker CM, Kaiser DA. Implant-retained cantilever fixed prosthesis:Where and when. J Prosthet Dent 2000;84: 432-435.
    • (2000) J Prosthet Dent , vol.84 , pp. 432-435
    • Becker, C.M.1    Kaiser, D.A.2
  • 51
    • 2442553639 scopus 로고    scopus 로고
    • Cantilever fixed prostheses utilizing dental implants: A 10-year retrospective analysis
    • Becker CM. Cantilever fixed prostheses utilizing dental implants: A 10-year retrospective analysis. Quintessence Int 2004;35: 437-441.
    • (2004) Quintessence Int , vol.35 , pp. 437-441
    • Becker, C.M.1
  • 52
    • 0028435430 scopus 로고
    • Effect of cantilever length on stress transfer by implant-supported prostheses
    • White SN, Caputo AA, Anderkvist T. Effect of cantilever length on stress transfer by implant-supported prostheses. J Prosthet Dent 1994;71: 493-499.
    • (1994) J Prosthet Dent , vol.71 , pp. 493-499
    • White, S.N.1    Caputo, A.A.2    Anderkvist, T.3
  • 53
    • 0026305075 scopus 로고
    • Dutch consensus on guidelines for superstructures on endosseous implants in the edentulous mandible
    • van Waas MA, Denissen HW, de Koomen HA, et al. Dutch consensus on guidelines for superstructures on endosseous implants in the edentulous mandible. J Oral Implantol 1991;17: 390-392.
    • (1991) J Oral Implantol , vol.17 , pp. 390-392
    • van Waas, M.A.1    Denissen, H.W.2    de Koomen, H.A.3
  • 54
    • 84989546997 scopus 로고
    • A 10-year follow-up study of the masticatory system after treatment with osseointegrated implant bridges
    • Haraldson T, Zarb G. A 10-year follow-up study of the masticatory system after treatment with osseointegrated implant bridges. Scand J Dent Res 1988;96: 243-252.
    • (1988) Scand J Dent Res , vol.96 , pp. 243-252
    • Haraldson, T.1    Zarb, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.