메뉴 건너뛰기




Volumn 5, Issue 3, 1996, Pages 193-200

Comparison of strains transferred to a bone simulant between as-cast and postsoldered implant frameworks for a five-implant-supported fixed prosthesis

Author keywords

As cast; Bone; Dental implants; Soldered; Strains

Indexed keywords

ANALYSIS OF VARIANCE; ARTICLE; COMPARATIVE STUDY; COMPRESSIVE STRENGTH; DENTAL CARE; DENTAL SURGERY; DENTURE; INSTRUMENTATION; JAW; MATERIALS TESTING; MECHANICAL STRESS; PHYSIOLOGY; PROSTHESIS; TENSILE STRENGTH; TOOTH PROSTHESIS;

EID: 0030226140     PISSN: 1059941X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1532-849X.1996.tb00296.x     Document Type: Review
Times cited : (44)

References (22)
  • 1
    • 0026311384 scopus 로고
    • A comparison of impression techniques for a five-implant mandibular model
    • Carr AB: A comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 1991;6:448-455
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 448-455
    • Carr, A.B.1
  • 2
    • 0027563662 scopus 로고
    • Full-arch implant framework casting accuracy: Preliminary in vitro observation for in vivo testing
    • Carr AB, Stewart RB: Full-arch implant framework casting accuracy: Preliminary in vitro observation for in vivo testing. J Prosthod 1993;2:2-8
    • (1993) J Prosthod , vol.2 , pp. 2-8
    • Carr, A.B.1    Stewart, R.B.2
  • 3
    • 0030097958 scopus 로고    scopus 로고
    • In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw
    • Jemt T: In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw. Int J Oral Maxillofac Implants 1996;11:151-158
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 151-158
    • Jemt, T.1
  • 4
    • 0029351262 scopus 로고
    • Three-dimensional distortion of gold alloy castings and welded titanium frameworks. Measurements of the precision of fit between completed implant prostheses and the master casts in routine edentulous situations
    • Jemt T: Three-dimensional distortion of gold alloy castings and welded titanium frameworks. Measurements of the precision of fit between completed implant prostheses and the master casts in routine edentulous situations. J Oral Rehabil 1995;22:557-564
    • (1995) J Oral Rehabil , vol.22 , pp. 557-564
    • Jemt, T.1
  • 5
    • 0026214839 scopus 로고
    • Production of accurately fitting full-arch implant frameworks: Part I - Clinical procedures
    • Goll GE: Production of accurately fitting full-arch implant frameworks: Part I - Clinical procedures. J Prosthet Dent 1991;66:377-384
    • (1991) J Prosthet Dent , vol.66 , pp. 377-384
    • Goll, G.E.1
  • 6
    • 0022666114 scopus 로고
    • A fixed prosthodontic technique for mandibular osseointegrated titanium implants
    • Loos LG: A fixed prosthodontic technique for mandibular osseointegrated titanium implants. J Prosthet Dent 1986;55: 232-249
    • (1986) J Prosthet Dent , vol.55 , pp. 232-249
    • Loos, L.G.1
  • 7
    • 0024624228 scopus 로고
    • Modified casting technique for osseointegrated fixed prosthesis fabrication: A preliminary report
    • Parel SE: Modified casting technique for osseointegrated fixed prosthesis fabrication: A preliminary report. Int J Oral Maxillofac Implants 1989;4:33-40
    • (1989) Int J Oral Maxillofac Implants , vol.4 , pp. 33-40
    • Parel, S.E.1
  • 8
    • 0025377491 scopus 로고
    • Soldering technique for osseointegrated implant prostheses
    • Sutherland JK, Hallam RF: Soldering technique for osseointegrated implant prostheses. J Prosthet Dent 1990;63:242-244
    • (1990) J Prosthet Dent , vol.63 , pp. 242-244
    • Sutherland, J.K.1    Hallam, R.F.2
  • 9
    • 0026825389 scopus 로고
    • Electrical discharge machining in dentistry
    • Van Roekel NB: Electrical discharge machining in dentistry. Int J Prosthodont 1992;5:114-121
    • (1992) Int J Prosthodont , vol.5 , pp. 114-121
    • Van Roekel, N.B.1
  • 10
    • 0027018790 scopus 로고
    • Fixed implant-supported prostheses with welded titanium frameworks
    • Jemt T, Linden B: Fixed implant-supported prostheses with welded titanium frameworks. Int J Periodont Rest Dent 1992;12:177-183
    • (1992) Int J Periodont Rest Dent , vol.12 , pp. 177-183
    • Jemt, T.1    Linden, B.2
  • 11
    • 0027587065 scopus 로고
    • Adhesive abutment cylinder luting
    • Stumpel LJ, Quon SJ: Adhesive abutment cylinder luting. J Prosthet Dent 1993;69:398-400
    • (1993) J Prosthet Dent , vol.69 , pp. 398-400
    • Stumpel, L.J.1    Quon, S.J.2
  • 12
    • 84989001629 scopus 로고
    • Photoelastic analysis of stress distribution transmitted from a fixed prosthesis attached to osseointegrated implants
    • Waskewicz GA, Ostrowski JS, Parks VJ: Photoelastic analysis of stress distribution transmitted from a fixed prosthesis attached to osseointegrated implants. Int J Oral Maxillofac Implants 1994;9:405-411
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 405-411
    • Waskewicz, G.A.1    Ostrowski, J.S.2    Parks, V.J.3
  • 13
    • 0027620312 scopus 로고
    • The fit of Procera titanium crowns. An in vitro and clinical study
    • Karlsson S: The fit of Procera titanium crowns. An in vitro and clinical study. Acta Odontol Scand 1993;51:129-134
    • (1993) Acta Odontol Scand , vol.51 , pp. 129-134
    • Karlsson, S.1
  • 15
    • 0026218667 scopus 로고
    • Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup
    • Jemt T: Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991;6:270-276
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 270-276
    • Jemt, T.1
  • 16
    • 0025471133 scopus 로고
    • The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered
    • Zarb GA, Schmitt A: The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: Problems and complications encountered. J Prosthet Dent 1990;64:185-194
    • (1990) J Prosthet Dent , vol.64 , pp. 185-194
    • Zarb, G.A.1    Schmitt, A.2
  • 17
    • 28644449889 scopus 로고
    • Effect of prosthetic superstructure accuracy on the osseointegrated implant tissue interface
    • abstr 17
    • Carr AB, Michaels GC, Larsen PE, et al: Effect of prosthetic superstructure accuracy on the osseointegrated implant tissue interface (abstr 17). J Oral Maxillofac Surg 1993;51 (suppl 3):174
    • (1993) J Oral Maxillofac Surg , vol.51 , Issue.3 SUPPL. , pp. 174
    • Carr, A.B.1    Michaels, G.C.2    Larsen, P.E.3
  • 20
    • 0026488291 scopus 로고
    • Perspectives: Bone's mechanical usage windows
    • Frost HM: Perspectives: Bone's mechanical usage windows. Bone and Mineral 1992;19:257-271
    • (1992) Bone and Mineral , vol.19 , pp. 257-271
    • Frost, H.M.1
  • 21
    • 0028253303 scopus 로고
    • Wolff's law and bone's structural adaptations to mechanical usage: An overview for clinicians
    • Frost HM: Wolff's law and bone's structural adaptations to mechanical usage: An overview for clinicians. Angle Orthod 1994;64:175-188
    • (1994) Angle Orthod , vol.64 , pp. 175-188
    • Frost, H.M.1
  • 22
    • 0029439074 scopus 로고
    • Comparison of strains transferred to a bone simulant among implant overdenture bars with various levels of misfit
    • Clelland NL, Papazoglou E, Carr AB, et al: Comparison of strains transferred to a bone simulant among implant overdenture bars with various levels of misfit. J Prosthod 1995;4:243-250
    • (1995) J Prosthod , vol.4 , pp. 243-250
    • Clelland, N.L.1    Papazoglou, E.2    Carr, A.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.