메뉴 건너뛰기




Volumn 35, Issue 6, 2004, Pages 437-441

Cantilever fixed prostheses utilizing dental implants: A 10-year retrospective analysis

Author keywords

Cantilever prosthesis; Implant; Osseointegration

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; DENTURE; FEMALE; FRACTURE; HUMAN; LITERATURE; MALE; MAXILLA; PATIENT MONITORING; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 2442553639     PISSN: 00336572     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (41)

References (59)
  • 1
    • 0022070302 scopus 로고
    • A long term prognosis for the free-end saddle bridge
    • Isikowitz L. A long term prognosis for the free-end saddle bridge. J Oral Rehabil 1985;12:247-262.
    • (1985) J Oral Rehabil , vol.12 , pp. 247-262
    • Isikowitz, L.1
  • 2
    • 0022764552 scopus 로고
    • Technical failures and some related clinical complications in extensive fixed prosthodontics. An epidemiological study of long-term clinical quality
    • Randow K, Glantz PO, Zoger B. Technical failures and some related clinical complications in extensive fixed prosthodontics. An epidemiological study of long-term clinical quality. Acta Odontol Scand 1986;44:241-255.
    • (1986) Acta Odontol Scand , vol.44 , pp. 241-255
    • Randow, K.1    Glantz, P.O.2    Zoger, B.3
  • 3
    • 0024306740 scopus 로고
    • Failure and length of service in fixed prosthodontics after long-term function
    • Karlsson S. Failure and length of service in fixed prosthodontics after long-term function. Swed Dent J 1989;13: 185-192.
    • (1989) Swed Dent J , vol.13 , pp. 185-192
    • Karlsson, S.1
  • 4
    • 84916193989 scopus 로고
    • Multi-unit bridges on reduced periodontal support
    • Dahl B, Orstavik D, Karlsen K. Multi-unit bridges on reduced periodontal support. IADR Scandinavian Division 1987;120(special issue):84.
    • (1987) IADR Scandinavian Division , vol.120 , Issue.SPEC. ISSUE , pp. 84
    • Dahl, B.1    Orstavik, D.2    Karlsen, K.3
  • 5
    • 0018461740 scopus 로고
    • A longitudinal study of combined periodontal and prosthetic treatment of patients with advanced periodontal disease
    • Nyman S, Lindhe J. A longitudinal study of combined periodontal and prosthetic treatment of patients with advanced periodontal disease. J Periodontol 1979;50:409-414.
    • (1979) J Periodontol , vol.50 , pp. 409-414
    • Nyman, S.1    Lindhe, J.2
  • 6
    • 0020182266 scopus 로고
    • The capacity of reduced periodontal tissues to support fixed bridgework
    • Nyman S, Ericsson I. The capacity of reduced periodontal tissues to support fixed bridgework. J Clin Periodontol 1982;9:409-414.
    • (1982) J Clin Periodontol , vol.9 , pp. 409-414
    • Nyman, S.1    Ericsson, I.2
  • 7
    • 0026231295 scopus 로고
    • Long-term prognosis of existing polyunit cantilevered fixed partial denture
    • Laurell L, Lundgren D, Falk H, Hugoson A. Long-term prognosis of existing polyunit cantilevered fixed partial denture. J Prosthet Dent 1991;66:545-552.
    • (1991) J Prosthet Dent , vol.66 , pp. 545-552
    • Laurell, L.1    Lundgren, D.2    Falk, H.3    Hugoson, A.4
  • 8
    • 0040559621 scopus 로고
    • Tissue-Integrated Prostheses Osseointegration in Clinical Dentistry
    • Brånemark P-I, Zarb GA, Albrektsson T. Tissue-Integrated Prostheses Osseointegration in Clinical Dentistry. Chicago: Quintessence, 1985:241-270,283-287.
    • (1985) Chicago: Quintessence , pp. 241-270
    • Brånemark, P.-I.1    Zarb, G.A.2    Albrektsson, T.3
  • 9
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rockler B, Brånemark P-I. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.-I.4
  • 10
    • 0027015903 scopus 로고
    • A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects
    • Naert I, Quirynen M, van Steenberghe D, Darius P. A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects. J Prosthet Dent 1992; 68:949-956.
    • (1992) J Prosthet Dent , vol.68 , pp. 949-956
    • Naert, I.1    Quirynen, M.2    Van Steenberghe, D.3    Darius, P.4
  • 11
    • 0028390422 scopus 로고
    • Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: A 5-year report
    • Hemmings KW, Schmitt A, Zarb GA. Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: A 5-year report. Int J Oral Maxillofac Implants 1994;9:191-196.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 191-196
    • Hemmings, K.W.1    Schmitt, A.2    Zarb, G.A.3
  • 12
    • 0028434828 scopus 로고
    • A comparative prospective study of splinted and unsplinted Brånemark implants in mandibular overdenture therapy: A preliminary report
    • Naert I, Quirynen M, Hooghe M, van Steenberghe D. A comparative prospective study of splinted and unsplinted Brånemark implants in mandibular overdenture therapy: A preliminary report. J Prosthet Dent 1994;71:486-492.
    • (1994) J Prosthet Dent , vol.71 , pp. 486-492
    • Naert, I.1    Quirynen, M.2    Hooghe, M.3    Van Steenberghe, D.4
  • 13
    • 0025471133 scopus 로고
    • The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered
    • Zarb GA, Smith A. The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered. J Prosthet Dent 1990;64:185-194.
    • (1990) J Prosthet Dent , vol.64 , pp. 185-194
    • Zarb, G.A.1    Smith, A.2
  • 14
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years
    • Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994; 9:169-178.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 169-178
    • Kallus, T.1    Bessing, C.2
  • 15
    • 0028391163 scopus 로고
    • Implant treatment in partially edentulous patients: A report on prostheses after 3 years
    • Gunne J, Jemt T, Linden B. Implant treatment in partially edentulous patients: A report on prostheses after 3 years. Int J Prosthodont 1994;7:143-148.
    • (1994) Int J Prosthodont , vol.7 , pp. 143-148
    • Gunne, J.1    Jemt, T.2    Linden, B.3
  • 17
    • 0026218667 scopus 로고
    • Failures and complications in 391 consecutively inserted prostheses supported by Brånemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup
    • Jemt T. Failures and complications in 391 consecutively inserted prostheses supported by Brånemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991;6:270-276.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 270-276
    • Jemt, T.1
  • 18
    • 0027026658 scopus 로고
    • A multicenter study of overdentures supported by Brånemark implants
    • Johns RB, Jemt T, Heath MR, et al. A multicenter study of overdentures supported by Brånemark implants. Int J Oral Maxillofac Implants 1992;7:513-522.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 513-522
    • Johns, R.B.1    Jemt, T.2    Heath, M.R.3
  • 19
    • 0031586908 scopus 로고    scopus 로고
    • Complications and maintenance requirements of implant-supported prostheses provided in a UK dental hospital
    • Allen PF, McMillan AS, Smith DG. Complications and maintenance requirements of implant-supported prostheses provided in a UK dental hospital. Br Dent J 1997;182:298-302.
    • (1997) Br Dent J , vol.182 , pp. 298-302
    • Allen, P.F.1    McMillan, A.S.2    Smith, D.G.3
  • 20
    • 0027793057 scopus 로고
    • Oral implant treatment in posterior partially edentulous jaws: A 5-year follow-up report
    • Jemt T, Lekholm U. Oral implant treatment in posterior partially edentulous jaws: A 5-year follow-up report. Int J Oral Maxillofac Implants 1993;8:635-640.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 635-640
    • Jemt, T.1    Lekholm, U.2
  • 21
    • 0026832538 scopus 로고
    • Failure and complications in 127 consecutively placed fixed partial prostheses supported by Brånemark implants from prosthetic treatment to annual checkup
    • Jemt T, Linden B, Lekholm U. Failure and complications in 127 consecutively placed fixed partial prostheses supported by Brånemark implants from prosthetic treatment to annual checkup. Int J Oral Maxillofac Implants 1992;7:40-44.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 40-44
    • Jemt, T.1    Linden, B.2    Lekholm, U.3
  • 22
    • 0025493944 scopus 로고
    • Applicability of osseointegrated oral implants in the rehabilitation of partial edentulism: A prospective multicenter study on 558 fixtures
    • van Steenberghe D, Lekholm U, Bolender C, et al. Applicability of osseointegrated oral implants in the rehabilitation of partial edentulism: A prospective multicenter study on 558 fixtures. Int J Oral Maxillofac Implants 1990;5:272-281.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 272-281
    • Van Steenberghe, D.1    Lekholm, U.2    Bolender, C.3
  • 23
    • 0029684525 scopus 로고    scopus 로고
    • The edentulous predicament. I: A prospective study of the effectiveness of implant supported fixed prostheses
    • Zarb GA, Schmitt A. The edentulous predicament. I: A prospective study of the effectiveness of implant supported fixed prostheses. J Am Dent Assoc 1996;127:59-65.
    • (1996) J Am Dent Assoc , vol.127 , pp. 59-65
    • Zarb, G.A.1    Schmitt, A.2
  • 24
    • 0026921680 scopus 로고
    • Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system
    • Quirynen M, Naert I, van Steenberghe D. Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system. Clin Oral Implants Res 1992;3:104-111.
    • (1992) Clin Oral Implants Res , vol.3 , pp. 104-111
    • Quirynen, M.1    Naert, I.2    Van Steenberghe, D.3
  • 26
    • 0026214936 scopus 로고
    • Fixed implant rehabilitation for the edentulous maxilla
    • Taylor TD. Fixed implant rehabilitation for the edentulous maxilla. Int J Oral Maxillofac Implants 1991;6:329-337.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 329-337
    • Taylor, T.D.1
  • 27
    • 0026919783 scopus 로고
    • Prosthesis design for osseointegrated implants in the edentulous maxilla
    • Desjardins RP. Prosthesis design for osseointegrated implants in the edentulous maxilla. Int J Oral Maxillofac Implants 1992;7:311-320.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 311-320
    • Desjardins, R.P.1
  • 28
    • 0027581959 scopus 로고
    • Edentulous implants: Overdenture versus fixed
    • DeBoer J. Edentulous implants: Overdenture versus fixed. J Prosthet Dent 1993;69:386-390.
    • (1993) J Prosthet Dent , vol.69 , pp. 386-390
    • DeBoer, J.1
  • 29
    • 0036632491 scopus 로고    scopus 로고
    • Twenty years of progress in implant prosthodontics
    • Taylor TD, Agar JR. Twenty years of progress in implant prosthodontics. J Prosthet Dent 2002;88:89-95.
    • (2002) J Prosthet Dent , vol.88 , pp. 89-95
    • Taylor, T.D.1    Agar, J.R.2
  • 30
    • 0025900565 scopus 로고
    • Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs
    • Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res 1991;25:889-902.
    • (1991) J Biomed Mater Res , vol.25 , pp. 889-902
    • Buser, D.1    Schenk, R.K.2    Steinemann, S.3    Fiorellini, J.P.4    Fox, C.H.5    Stich, H.6
  • 31
    • 0001047110 scopus 로고
    • The influence of various titanium surfaces on the interface shear strength between implant and bone
    • Wilke HJ, Claes L, Steinemann S. The influence of various titanium surfaces on the interface shear strength between implant and bone. Adv Biomater 1990;9:309-314.
    • (1990) Adv Biomater , vol.9 , pp. 309-314
    • Wilke, H.J.1    Claes, L.2    Steinemann, S.3
  • 32
    • 0030224083 scopus 로고    scopus 로고
    • Evaluation of an endosseous titanium implant with sandblasted and acid-etched surface in the canine mandible: Radiographic results
    • Cochran DL, Nummikoski PV, Higginbottom FL, Hermann JS, Makins SR, Buser D. Evaluation of an endosseous titanium implant with sandblasted and acid-etched surface in the canine mandible: Radiographic results. Clin Oral Implants Res 1996;7:240-252.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 240-252
    • Cochran, D.L.1    Nummikoski, P.V.2    Higginbottom, F.L.3    Hermann, J.S.4    Makins, S.R.5    Buser, D.6
  • 34
    • 0030635284 scopus 로고    scopus 로고
    • Titanium surface roughness alter responsiveness of MG63 osteoblast-like cells to 1 alpha, 25-(OH)2D3
    • Boyan B, Batzer R, Keiswetter K, et al. Titanium surface roughness alter responsiveness of MG63 osteoblast-like cells to 1 alpha, 25-(OH)2D3. J Biomed Mater Res 1998;39: 77-85.
    • (1998) J Biomed Mater Res , vol.39 , pp. 77-85
    • Boyan, B.1    Batzer, R.2    Keiswetter, K.3
  • 35
    • 0032053958 scopus 로고    scopus 로고
    • Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface. A histometric study on the canine mandible
    • Cochran DL, Schenk R, Lussi A, Higginbottom FL, Buser D. Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface. A histometric study on the canine mandible. J Biomed Mater Res 1998;40:1-11.
    • (1998) J Biomed Mater Res , vol.40 , pp. 1-11
    • Cochran, D.L.1    Schenk, R.2    Lussi, A.3    Higginbottom, F.L.4    Buser, D.5
  • 36
    • 0033135482 scopus 로고    scopus 로고
    • The interface shear strength of titanium implant with a sandblasted and acid-etched surface. A biomechanical study in the maxilla of miniature pigs
    • Buser D, Nydegger T, Hirt HP, et al. The interface shear strength of titanium implant with a sandblasted and acid-etched surface. A biomechanical study in the maxilla of miniature pigs. J Biomed Mater Res 1999;45:75-83.
    • (1999) J Biomed Mater Res , vol.45 , pp. 75-83
    • Buser, D.1    Nydegger, T.2    Hirt, H.P.3
  • 37
    • 0032159407 scopus 로고    scopus 로고
    • Removal torque values of titanium implants in the maxilla of miniature pigs. A direct comparison of sandblasted and acid-etched with machined and acid-etched screw implants
    • Buser D, Nydegger T, Hirt HP, Cochran DL, Nolte LP. Removal torque values of titanium implants in the maxilla of miniature pigs. A direct comparison of sandblasted and acid-etched with machined and acid-etched screw implants. Int J Oral Maxillofac Implants 1998;13:611-619.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 611-619
    • Buser, D.1    Nydegger, T.2    Hirt, H.P.3    Cochran, D.L.4    Nolte, L.P.5
  • 38
    • 0031152016 scopus 로고    scopus 로고
    • Long-term evaluation of nonsubmerged ITI implants. Part I: 8-Year life table analysis of a prospective multi-center study of 2359 implants
    • Buser D, Mericske-Stern R, Bernard JP, et al. Long-term evaluation of nonsubmerged ITI implants. Part I: 8-year life table analysis of a prospective multi-center study of 2359 implants. Clin Oral Implants Res 1997;8:161-172.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 161-172
    • Buser, D.1    Mericske-Stern, R.2    Bernard, J.P.3
  • 39
    • 0038505314 scopus 로고    scopus 로고
    • Implant prosthodontic management of partially edentulous patients missing posterior teeth: The Toronto experience
    • Nikolai AJ, Zarb GA. Implant prosthodontic management of partially edentulous patients missing posterior teeth: The Toronto experience. J Prosthet Dent 2003;89:352-359.
    • (2003) J Prosthet Dent , vol.89 , pp. 352-359
    • Nikolai, A.J.1    Zarb, G.A.2
  • 40
    • 0035461999 scopus 로고    scopus 로고
    • Managing the posterior mandible of partially edentulous patients with short, porous surfaced dental implants: Early data from a clinical trial
    • Deporter C, Pilliar RM, Todescan R, Watson P, Pharoah M. Managing the posterior mandible of partially edentulous patients with short, porous surfaced dental implants: Early data from a clinical trial. Int J Oral Maxillofac Implants 2001;16:653-658.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 653-658
    • Deporter, C.1    Pilliar, R.M.2    Todescan, R.3    Watson, P.4    Pharoah, M.5
  • 41
    • 0035293260 scopus 로고    scopus 로고
    • A prospective multicenter clinical study of the Osseotite implant: Four-year interim report
    • Testori T, Wiseman L, Wolfe S, Porter SS. A prospective multicenter clinical study of the Osseotite implant: Four-year interim report. Int J Oral Maxillofac Implants 2001;16: 193-200.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 193-200
    • Testori, T.1    Wiseman, L.2    Wolfe, S.3    Porter, S.S.4
  • 42
    • 0031067775 scopus 로고    scopus 로고
    • Biologic width around titanium implants. A histometric analysis of the implant-gingival junction around unloaded and loaded non-submerged implants in the canine mandible
    • Cochran D, Herman J, Schenk R, Higginbottom F, Buser D. Biologic width around titanium implants. A histometric analysis of the implant-gingival junction around unloaded and loaded non-submerged implants in the canine mandible. J Periodontol 1997;68:186-198.
    • (1997) J Periodontol , vol.68 , pp. 186-198
    • Cochran, D.1    Herman, J.2    Schenk, R.3    Higginbottom, F.4    Buser, D.5
  • 44
    • 0030277405 scopus 로고    scopus 로고
    • The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit
    • Carr AB, Gerald DA, Larsen PK. The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit. J Prosthet Dent 1996; 76:500-509.
    • (1996) J Prosthet Dent , vol.76 , pp. 500-509
    • Carr, A.B.1    Gerald, D.A.2    Larsen, P.K.3
  • 45
    • 0035258739 scopus 로고    scopus 로고
    • Bone reactions adjacent to titanium implants subjected to static load. A study in the dog (I)
    • Gotfredsen K, Berglundh T, Lindhe J. Bone reactions adjacent to titanium implants subjected to static load. A study in the dog (I). Clin Oral Implants Res 2001;12:1-8.
    • (2001) Clin Oral Implants Res , vol.12 , pp. 1-8
    • Gotfredsen, K.1    Berglundh, T.2    Lindhe, J.3
  • 46
    • 0031609120 scopus 로고    scopus 로고
    • Prosthodontic problems and limitations associated with osseointegration
    • Taylor D. Prosthodontic problems and limitations associated with osseointegration. J Prosthet Dent 1998;79:74-78.
    • (1998) J Prosthet Dent , vol.79 , pp. 74-78
    • Taylor, D.1
  • 47
    • 0034303173 scopus 로고    scopus 로고
    • Implant-retained cantilever fixed prosthesis: Where and when
    • Becker CM, Kaiser DA. Implant-retained cantilever fixed prosthesis: Where and when. J Prosthet Dent 2000;84: 432-435.
    • (2000) J Prosthet Dent , vol.84 , pp. 432-435
    • Becker, C.M.1    Kaiser, D.A.2
  • 48
    • 0034242801 scopus 로고    scopus 로고
    • Guidelines for splinting implants
    • Becker CM, Kaiser D. Guidelines for splinting implants. J Prosthet Dent 2000;84:210-214.
    • (2000) J Prosthet Dent , vol.84 , pp. 210-214
    • Becker, C.M.1    Kaiser, D.2
  • 49
    • 0036836264 scopus 로고    scopus 로고
    • The effect of smoking on achieving osseointegration of surface-modified implants: A clinical report
    • Kumar A, Jaffin RA, Berman C. The effect of smoking on achieving osseointegration of surface-modified implants: A clinical report. Int J Oral Maxillofac Implants 2002;17: 816-819.
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 816-819
    • Kumar, A.1    Jaffin, R.A.2    Berman, C.3
  • 50
    • 0024780953 scopus 로고
    • Immediate implant placement into extraction sites: Surgical and restorative advantages
    • Lazzara RJ. Immediate implant placement into extraction sites: Surgical and restorative advantages. Int J Periodontics Restorative Dent 1989;9:333-359.
    • (1989) Int J Periodontics Restorative Dent , vol.9 , pp. 333-359
    • Lazzara, R.J.1
  • 51
    • 0030097948 scopus 로고    scopus 로고
    • Immediate placement of implants into extraction sockets: Report of a pilot procedure
    • Rosenquist B, Grenthe B. Immediate placement of implants into extraction sockets: Report of a pilot procedure. Int J Oral Maxillofac Implants 1996;11:205-209.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 205-209
    • Rosenquist, B.1    Grenthe, B.2
  • 52
    • 0027018452 scopus 로고
    • The immediate implant. Bone preservation and bone regeneration
    • Werbitt M, Goldberg P. The immediate implant. Bone preservation and bone regeneration. Int J Periodontics Restorative Dent 1992;12:206-217.
    • (1992) Int J Periodontics Restorative Dent , vol.12 , pp. 206-217
    • Werbitt, M.1    Goldberg, P.2
  • 53
    • 0028310179 scopus 로고
    • The use of e-PTFE barrier membranes for bone promotion around titanium implants placed into extraction sockets. A prospective multicenter study
    • Becker W, Dahlin C, Becker BE, et al. The use of e-PTFE barrier membranes for bone promotion around titanium implants placed into extraction sockets. A prospective multicenter study. Int J Oral Maxillofac Implants 1994;9:31-40.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 31-40
    • Becker, W.1    Dahlin, C.2    Becker, B.E.3
  • 54
    • 0031262601 scopus 로고    scopus 로고
    • Placement of implants into fresh extraction sites: 4 to 7 years retrospective evaluation of 95 immediate implants
    • Schwartz-Arad D, Chaushu G. Placement of implants into fresh extraction sites: 4 to 7 years retrospective evaluation of 95 immediate implants. J Periodontol 1997;68:1110-1116.
    • (1997) J Periodontol , vol.68 , pp. 1110-1116
    • Schwartz-Arad, D.1    Chaushu, G.2
  • 55
    • 0026311498 scopus 로고
    • Histologic evaluation of dental endosseous implants placed in surgically created extraction defects
    • Knox R, Caudeil R, Meffert R. Histologic evaluation of dental endosseous implants placed in surgically created extraction defects. Int J Periodontics Restorative Dent 1991;11: 365-376.
    • (1991) Int J Periodontics Restorative Dent , vol.11 , pp. 365-376
    • Knox, R.1    Caudeil, R.2    Meffert, R.3
  • 56
    • 0027170280 scopus 로고
    • Evaluation of guided bone generation around implants placed into fresh extraction sockets: An experimental study in dogs
    • Gotfredsen K, Nimb L, Buser D, Hjörting-Hansen E. Evaluation of guided bone generation around implants placed into fresh extraction sockets: An experimental study in dogs. J Oral Maxillofac Surg 1993;51:879-884.
    • (1993) J Oral Maxillofac Surg , vol.51 , pp. 879-884
    • Gotfredsen, K.1    Nimb, L.2    Buser, D.3    Hjörting-Hansen, E.4
  • 57
    • 0032060541 scopus 로고    scopus 로고
    • Implants placed in immediate extraction sites: A report of histologic and histometric analyses of human biopsies
    • Wilson TG, Schenk R, Buser D, Cochran D. Implants placed in immediate extraction sites: A report of histologic and histometric analyses of human biopsies. Int J Oral Maxillofac Implants 1998;13:333-341.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 333-341
    • Wilson, T.G.1    Schenk, R.2    Buser, D.3    Cochran, D.4
  • 59
    • 0035199397 scopus 로고    scopus 로고
    • Immediate implantation in fresh extraction sockets. A controlled clinical and histological study in man
    • Paolantonio M, Dolci M, Scarano A, et al. Immediate implantation in fresh extraction sockets. A controlled clinical and histological study in man. J Periodontol 2001;72: 1560-1571.
    • (2001) J Periodontol , vol.72 , pp. 1560-1571
    • Paolantonio, M.1    Dolci, M.2    Scarano, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.